TECHNICAL SPECIFICATIONS
General
Maximum flow rate 800 m3/h 3500 Usgpm Consult manufacturer for
optimum flow depending on
filtration degree& water quality.
Min. working pressure 2.5 bar 35 psi or lower if pressure is increased
for flushing.
Max. working pressure 10 bar 150 psi 16 bar = 240 psi upon request.
2
Filter area 10,000 cm 1550 in2
Inlet/Outlet diameter 200,250, 300, 350 mm 8", 10", 12",14" Flange standards per request.
Filter housing 500 mm 20" Epoxy-coated steel, or other on
request.
Max. working temperature 800C 1760F
Weight 200 mm = 310 Kg 08" = 680 lb.
250 mm = 325 Kg 10" =715 lb.
300 mm = 350 Kg 12" = 770 lb.
350 mm = 380 Kg 14" = 840 lb.
Flushing data
Exhaust valve 80 mm 3"
Flushing cycle time 30 - 40 seconds 30 - 40 seconds
Wasted water per cycle 500 liter 132 gallon at 2 bar = 30 psi
Minimum flow for flushing 50 m3/h 220 USgpm at 2 bar = 30 psi
Construction materials
Filter Housing and Lid Epoxy-coated carbon steel 37-2 (Stainless Steel 316 available on request).
Screens Stainless Steel 316
Cleaning mechanism Stainless Steel 316, POM
Exhaust valve Epoxy-coated cast iron, Natural Rubber
Seals Synthetic Rubber, Teflon
Control Aluminum, Brass, Stainless Steel, PVC
Installation and Maintenance - EBS Page - 3 - Amiad Filtration Systems (1997) Ltd.
SAFETY INSTRUCTIONS
General
1. Prior to installation or any treatment given to the filter, read carefully the installation and operation
instructions.
2. While treating the filter all conventional safety instructions should be observed in order to avoid danger to the
workers, the public or to property in the vicinity.
3. Please note, the filters enters into a flushing mode automatically, without prior warning.
4. No changes or modification to the equipment are permitted without a written notification given by the
manufacturer or by its representative, on the manufacturer behalf.
Installation
1. Install the filter according to the installation instructions detailed in this manual.
2. Make sure to leave enough clearance so as to enable easy access for future treatments and safe maintenance
operations.
3. Electric wiring should be performed by an authorized electrician only; using standardized and approved
components.
4. Install main power disconnect cut-off switch close to the control panel.
5. If the control panel is installed far away and there is no eye contact with the filter, a power disconnect cut-off
switch should be installed near each filter unit.
6. Installation of the filter should be performed so as to avoid direct water splashing on the electrical
components or on the control panel.
7. Extra safety devices should be installed on hot water applications to avoid skin burn danger.
Installation and Maintenance - EBS Page - 4 - Amiad Filtration Systems (1997) Ltd.
DIMENSIONAL DRAWING AND RECOMMENDED INSTALLATION
Key:
Dimensions in mm (inches).
1. 12" EBS filter
2. 12" Non-return check valve
3. 12" Downstream valve
4. 12" Bypass valve
5. 12" Inlet butterfly valve
6. 3" Exhaust valve
Installation and Maintenance - EBS Page - 5 - Amiad Filtration Systems (1997) Ltd.
DESCRIPTION OF FILTER OPERATION
Filtering process:
The EBS is a sophisticated yet easy-to-operate automatic filter, with a self-cleaning mechanism driven by an
electric motor. The EBS is designed to work with various types of screens in filtration degrees from 500 to 10
micron, and is available in 8", 10", 12" and 14" inlet/outlet diameter.
The water enters through the inlet pipe into the fine screen from inside out. The "filtration cake" accumulates on
the fine screen surface and causes head loss to develop.
Self-cleaning process:
The EBS will start the self-cleaning process when the pressure differential across the screen reaches a pre-set
value or a predetermined lapse of time.
Cleaning of the filter element is carried out by the suction scanner, which rotates in a spiral movement while
removing the filtration cake from the screen and expels it out through the exhaust valve.
The scanner rotation is operated by a 2-way (fwd/rev) drive unit which is attached to the scanner by a threaded
shaft, providing the linear movement.
The exhaust valve is activated for the duration of the cleaning cycle by a 3-way solenoid. During the self-cleaning
process, which takes approximately 35 seconds, filtered water continues to flow downstream of the filter.
The filtration system may enter a malfunction mode in the following cases:
1st. When there is a continuous signal from the pressure differential switch for duration of more than 15 minutes.
This means that the self-cleaning process is not successful.
2nd. When the motor protector was activated, either manually or due to overload.
3rd. As a result of a malfunction in the limit switches.
Initiation of self-cleaning:
The filter will enter the self-cleaning process as a result of any of the following causes:
1. A signal from the Pressure Differential Switch (PDS) - The PDS which is situated on the filter body, sends an
electric signal when the pressure differential across the screen reaches the pre-set value (usually 0.5 bar =7
psi). The control board registers the signal and operates the flushing process according to its program.
2. Manually pressing the "TEST" push button at the control board.
3. The TIMER installed in the control board allows operation of self-cleaning process at time intervals that can be
set up, independent from the head loss factor. The timer resets after every flushing cycle.
4. A signal from continual flushing switch - This switch in the control board allows operation in continuous
flushing mode; meaning, the filter is flushing itself all the time regardless of flow rate or water quality.
Installation and Maintenance - EBS Page - 6 - Amiad Filtration Systems (1997) Ltd.
INSTALLATION
Design recommendations
1. If flow increases and pressure drops dramatically for a long period of time during network filling-up, it is
recommended that a pressure sustaining valve is installed downstream of the filter. The pressure sustaining
valve will ensure a controlled filling-up of the line.
2. If continual water flow is essential even during maintenance period, it is recommended that a manual or
automatic by-pass is installed, and the isolating valves will be used to isolate each filter unit.
3. In places where there is an expected temporary worsening of water quality, it is possible to operate an
emergency flushing program. In order to do so, a hydraulic controlled valve has to be installed downstream of
the filter. For details, please consult the manufacturer.
Installation instructions
1. Select a convenient location for the installation of the filter where operation and maintenance will be optimum.
It is recommended that a lifting auxiliary is available for maintenance.
2. Install the filter vertically. Please note that a minimum clearance of 300 mm (12 In.) (not including a crane) is
required in order to allow disassembly of the unit.
3. Ensure the direction of flow according to the arrows marked on the filter housing.(flow outlet will always be
from the side; flow inlet is from the bottom).
4. Installation of a mechanical non-return valve downstream of the filter is required.
5. If possible, prior to installing the filter, flush the main line, at the connection point thoroughly, in order to
remove large objects which may damage the filters internal mechanism.
6. Install a drainage pipe to the exhaust valve (14). Minimum 3" diameter for a maximum pipe length of 20 meters
(60 feet), for longer drainage, 4" pipe diameter must be used for a maximum length of 40 meters (120 feet).
Please note that no restriction is allowed on the drainage pipe. For special applications, please consult the
manufacturer.
7. If the system is designed to operate with working pressure higher than 6 bar (85 psi), it is recommended that a
manual valve is installed on the exhaust pipe, in order to enable regulation of the flushing flow rate.
8. The user should arrange suitable lighting at the area of the filter to enable good visibility and safe maintenance.
9. The user should arrange suitable platforms and safety barriers to enable easy access to the filter without
climbing on pipes and other equipment.
IMPORTANT !!
♦ Prevent static backpressure or reverse flow through the filter.
♦ Install a non-return valve at the outlet of the filter.
♦ Install a manual or a hydraulic valve downstream of the filter.
Electric wiring
1. Install the control board in a dry and protected place (It is possible to order a special control board for out-
door installation).
2. Power connection to the control board:
a. Connect a three-phase voltage source through a semi-automatic switch, or 16 Amp. fuse to the L1 L2 L3
inlet at the terminal strip in the control board.
b. Earth the control board.
3. Power connection to the motor:
Connect the drive unit to the control panel by means of a 4 x 2.5 mm (12 or 14 AWG) wire in flex-conduct. Use
a long enough cable to allow removal of the drive unit and placing it near the filter for maintenance, without
having to disconnect it from the cable. (It is recommended that this installation meets or exceeds local or
national electrical codes, this is a "high" voltage connection).
4. Control wiring:
Connect between the control junction box and the control board by means of 6 x 1.5 mm 2 (16 AWG) wire in
flex-conduct. The numbers on the terminals in the board and in the junction box are identical.
Installation and Maintenance - EBS Page - 7 - Amiad Filtration Systems (1997) Ltd.
Start-up and first operation
1. Make sure the electric wiring is correct, according to the enclosed drawings.
2. Switch the control & 24V circuit breakers and the motor protector to ON. The motor will start operating.
The suction scanner shaft should turn clockwise and move downward to the filter housing until it reaches the
lower limit switch. If the motor rotates in the opposite direction, disconnect the electricity immediately and
change the direction of the motor rotation by changing between two phases.
The motor must stop when the limit switch plate reaches the lower limit switch and causes it to operate.
3. Operate a "dry" flushing cycle by pressing on the "TEST" push button. Make sure all flushing stages occur as
described in the filter description chapter of this manual.
4. Open the inlet valve to the filter, while the outlet valve remains closed or with an open by-pass valve (This will
keep the flow in the filter at a minimum), and operate a flushing cycle.
Make sure the exhaust valve opens and all stages of the flushing cycle are carried out. Attend to leakage, if any.
Close the 1/4" valve at the low pressure point of the pressure differential switch for 5 seconds. The filter will
start the flushing process. Open the 1/4" valve.
5. Gradually open the outlet valve and/or close the by-pass valve. Operate the filter at the designed hydraulic
conditions.
6. Set the timer for 6-8 hours.
7. Check and re-tight all bolts after the first week of operation.
Installation and Maintenance - EBS Page - 8 - Amiad Filtration Systems (1997) Ltd.
MAINTENANCE
General inspection
In order to check the proper operation of the filter, close the low-pressure 1/4" valve to the pressure differential
switch for a period of 5 seconds. This will initiate the self-cleaning cycle: Check that the exhaust valve opens, that
the scanner moves upwards, and when it reaches the top limit switch - verify that the exhaust valve closes.
Weekly maintenance
1. Check that the filter operates properly, following a general inspection.
2. Clean the 3/4" filter (close the 3/4" valve and operate a flushing cycle in order to release pressure and then
open the bowl).
3. Check that there is grease on the drive shaft, and drive bushing. Add grease if necessary.
4. Take care of any leakage from the scanner shaft. If necessary, replace the Sealing flange Internal O-Ring (24.1)
IMPORTANT !!
THE DRIVE SHAFT MUST BE LUBRICATED WITH HEAVY-DUTY, WATER RESISTANT GREASE
THAT WILL NOT OXIDIZE. (SHELL, DARINA EP-2 OR SIMILAR).
Installation and Maintenance - EBS Page - 9 - Amiad Filtration Systems (1997) Ltd.
DISMANTLING AND ASSEMBLING THE FILTER COMPONENTS
Opening the filter and disassembling its inner components is necessary for changing screens, periodic maintenance
and repairs.
Prior to opening the filter it is recommended to operate a flushing cycle by pressing the "TEST" push button.
Dismantling:
1. Disconnect electrical power.
2. Close the water and drain the filter housing.
3. Pull the electrical plug from the solenoid valve (13). Disconnect the raccord connector (17.1).
4. Unscrew the bolts (14.1) and remove exhaust valve (14).
5. Unscrew bolts (33) and remove drive unit (34). Put the drive unit on a dry and protected surface near the
filter. If the electric cable is not long enough, disconnect it from the motor.
6. Pull out the split pin (20.2) from the connecting pin (20.1) then pull out the connecting pin as well. If the
connecting pin is not facing one of the shaft housing windows, turn the drive shaft (20) a little. Use 17mm or
11/16 spanners.
7. Turn the drive shaft (20) counter clockwise so that it will be separated from the suction scanner shaft (7.4).
8. Unscrew bolts (29.2) and remove the limit switches sling without disconnecting and changing the limit
switches position.
9. Unscrew bolts (23) connecting shaft housing (22) to filter lid (10).
10. Pull up the shaft housing. Put it near the filter, make sure not to damage the limit switches electric wires. If
necessary, disconnect the wires from the connecting box (4). (Do not forget to mark all wires for proper
reconnections).
11. Remove O-ring seal (21).
12. Unscrew the housing bolts (11) and pull the lid using a crane or other lifting device, which is assembled
exactly above the lid center.
Note: the lid must be removed in a horizontal position in order to prevent damage to the suction scanner and
the upper bearing seals.
13. Remove and keep the two centering sleeves (9).
14. Remove the housing O-Ring (2).
15. Pull the scanner (7) and the screen (5) (including screen seals 5.1).
Installation and Maintenance - EBS Page - 10 - Amiad Filtration Systems (1997) Ltd.
PARTS SCHEDULE Do not translate
Refer to drawing on pages 12 -14 this page !!
NO. DESCRIPTION CAT. NO. NO. DESCRIPTION CAT. NO.
1 Housing (EBS, ABF-10000) 13-4XX7-11XX 19.6 Pressure gauge 1/4" (DI) 63-1073-1007
1.1 Ball valve 3/4" (Brass) 82-32-0007-1050 20 Drive shaft (EBS) 53-4074-1022
2 O-Ring P2-471 81-41-4000-0471 20.1 Connecting pin (EBS) 53-4074-1025
3 Lower bearing (ABF-10000, EBS) 63-4071-0012 20.2 Split pin 2 x 20 63-0403-0003
4 Electrical junction box 13-4074-6000 20.3 Drive shaft key (EBS) 53-4074-1024
4.1 Bolt M5 x 16 (St.St.) 85-2142-05-016 21 O-Ring P2-433 81-41-4000-0433
4.2 Nut M5 (St.St.) 85-2212-05-000 22 Drive shaft housing (EBS) 13-4074-1111
4.3 Washer M5 (St.St.) [x4] 85-2312-05-000 22.1 Drive shaft housing cover (EBS) 13-4074-1120
5 Weavewire screen (EBS) 13-4083-0XXX 23 Bolt M16 x 60 [x8] 85-1112-16-060
5.1 Hydraulic seal AM-04 81-41-4300-0401 23.1 Washer 5/8" (Galvanized) [x8] 85-1311-10-000
7 Suction scanner (EBS) 13-4074-5000 23.2 Washer 5/8" (Galvanized) [x8] 85-1311-10-000
7.2 Slotted spring pin 10 x 60 84-32-10-0016 23.3 Nut M16 [x8] 85-1212-16-000
7.3 Suction scanner nozzle (EBS) [x6] 53-4074-0132 24 O-Ring 38 x 4 [external] 81-41-4100-4038
7.4 Suction scanner shaft (EBS) 53-4074-1034 24.1 O-Ring 30 x 4 [internal] 81-41-4100-4030
8 Upper bearing (EBS) 63-4074-1027 25 Set screw M10 x 50 (St.St.) [x2] 85-2132-10-050
8.1 O-Ring P2-041 [external] 81-41-4000-0041 26 Sealing flange (EBS) 63-4074-1028
8.2 O-Ring 71 x 5 [internal] 81-41-4100-7150 27 Nut M10 (St.St.) [x2] 85-2212-10-000
9 Centering sleeve (ABF-10000, EBS) 63-4071-0011 27.1 Washer M10 (St.St.) [x2] 85-2312-10-000
10 Lid (EBS) 13-4077-1111 28 Limit switch plate (EBS) 53-4074-1012
11 Bolt M20 x 100 [x16] 85-1112-20-100 28.1 Set screw M4 x 16 (St.St.) [x2] 85-2132-04-016
11.1 Washer 3/4" [x16] 85-1311-12-000 29 Limit switch "NC" [lower] 82-23-0000-0101
11.2 Washer 3/4" [x16] 85-1311-12-000 29.1 Limit switch "NC" [upper] 82-23-0000-0101
11.3 Nut M20 [x16] 85-1212-20-000 29.2 Bolt M6 x 20 (St.St.) [x2] 85-2112-06-020
12 Flange seal 3" 81-41-4200-0300 29.3 Limit switch sling (EBS) 53-4074-2021
13 Solenoid valve 24V AC, "NO" (Gem-Sol) 82-21-0024-0001 29.4 Nut M6 (St.St.) [x2] 85-2212-06-000
Solenoid valve 24V AC, "NO" (ASCO) 82-21-0024-0010 29.5 Spring washer M6 (St.St.) [x2] 85-2322-06-000
13.1 L-Connector 5/16" x 1/4" 82-13-0692-0504 29.6 Washer M6 (St.St.) [x2] 85-2312-06-000
13.2 Air-brake tube 8 mm (5/16") 82-13-9100-0505 29.7 Washer M6 (St.St.) [x2] 85-2312-06-000
13.3 Connector 5/16" x 1/4" 82-13-0682-0504 29.8 Bolt M4 x 25 (St.St.) [x4] 85-2123-04-025
13.4 L-Connector 5/16" x 1/8" [with Gem-Sol] 82-13-0692-0502 29.9 Washer M4 (St.St.) [x4] 85-2312-04-000
Connector 5/16" x 1/4" [with Asco] 82-13-0682-0504 29.10 Lock nut M4 (St.St.) [x4] 85-2232-04-000
13.5 Air-brake tube 8 mm (5/16") 82-13-9100-0505 31 Drive bushing (EBS) 53-4074-1021
13.6 Connector 1/4" x 1/4" (Brass) 52-0100-0020 32 Bolt M6 x 35 (St.St.) 85-2112-06-035
14 Hydraulic valve 3" (GAL) 82-31-0030-0000 32.1 Lock nut M6 (St.St.) [x3] 85-2232-06-000
Hydraulic valve 3" (RAF) 82-31-9310-0000 32.2 Washer M6 (St.St.) 85-2312-06-000
Hydraulic valve 3" (RAM) 82-31-5030-0000 32.3 Washer M6 (St.St.) [x3] 85-2312-06-000
14.1 Bolt M16 x 65 [x4] 85-1112-16-065 33 Bolt M10 x 40 [x4] 85-1112-10-040
14.2 Washer 5/8" (Galvanized) [x4] 85-1311-10-000 33.1 Washer M10 (St.St.) [x4] 85-2312-10-000
14.3 Washer 5/8" (Galvanized) [x4] 85-1311-10-000 33.2 Washer M10 (St.St.) [x4] 85-2312-10-000
14.4 Nut M16 [x4] 85-1212-16-000 33.3 Nut M10 [x4] 85-1212-10-000
15 L-Connector 3/4"F-M (Galvanized) 83-3225-0073-0000 33.4 Spring washer M10 [x4] 85-1322-10-000
16 Ball valve 3/4" (Brass) 82-32-0007-1050 34 Drive unit (EBS) 53-4074-3503
17 3/4" Filter (AC), w/o valve, 200 micron 01-0702-1131-8020 34.1 Electric motor 380-480V 50/60 Hz 1/2 HP 82-92-5130-0000
17.1 Raccord nut 3/4" 63-0500-1033 34.2 Worm gear RMI 70, 70:1(71) 82-93-0000-0046
17.2 O-Ring P2-112 81-41-4000-0112 35 Drive shaft cover (EBS) 53-4074-0021
17.3 Raccord nipple 1/4" 63-0500-1032 35.1 Nut M6 (St.St.) [x2] 85-2212-06-000
17.4 L-Connector 5/16" x 1/4" 82-13-0692-0504 35.2 Set screw M6 x 45 [x2] 85-2132-06-045
18 Pressure differential switch (Midwest) 84-34-10-0003 35.3 Nut M6 (St.St.) [x2] 85-2212-06-000
18.1 Connector 5/16" x 1/8" 82-13-0682-0502 36 Drive shaft housing assembly see detailed Drg.
18.2 Connector 5/16" x 1/8" 82-13-0682-0502
18.3 Air-brake tube 8 mm (5/16") 82-13-9100-0505
18.4 L-Connector 5/16" x 1/4" 82-13-0692-0504
18.5 Set screw M6 x 25 (St.St.) [x2] 85-2162-06-025
18.6 Nut M6 (St.St.) [x2] 85-2212-06-000
18.7 Spring washer M6 (St.St.) [x2] 85-2322-06-000
18.8 Washer M6 (St.St.) [x2] 85-2312-06-000
18.9 Air-brake tube 8 mm (5/16") 82-13-9100-0505
18.10 L-Connector 5/16" x 1/4" 82-13-0692-0504
18.11 T-Connector 1/4" (Brass) 82-13-9000-0025
18.12 Manometer valve 1/4" 82-32-9002-1000
19 Three-way valve 1/4" 63-1073-1006
19.1 L-Connector 5/16" x 1/4" 82-13-0692-0504
19.2 L-Connector 5/16" x 1/4" 82-13-0692-0504
19.3 Air-brake tube 8 mm (5/16") 82-13-9100-0505
19.4 Connector 5/16" x 1/4" 82-13-0682-0504
19.5 T-Connector 1/4" (Brass) 82-13-9000-0025
Installation and Maintenance - EBS Page - 11 - Amiad Filtration Systems (1997) Ltd.
PARTS DRAWING Section 1
Installation and Maintenance - EBS Page - 12 - Amiad Filtration Systems (1997) Ltd.
PARTS DRAWING Section 2
Installation and Maintenance - EBS Page - 13 - Amiad Filtration Systems (1997) Ltd.
PARTS DRAWING Section 3
Installation and Maintenance - EBS Page - 14 - Amiad Filtration Systems (1997) Ltd.
PLC CONTROL SYSTEM (TYPE "D" - EBS)
Description of control panel components
1. Pilot lights:
Yellow - lights ON when power is on.
Red - lights ON when the control panel enters malfunction mode.
2. Push buttons:
TEST Manual operation of a flushing cycle.
RESET - clears the malfunction mode.
3. Flushing counter:
Counts the flushing cycles that occurred. Used for follow-up on the system operation.
5. Motor protector:
This switch protects the motor in case of short-circuit or overload. It is important to set amperage according to
the label of the motor. When this switch is tripped, the fault light will blink.
7. Transformer:
Electric supply to the various control components.
9. PLC:
A Programmable Logic Controller responsible for the control panel operation according to a preset program.
NOTE: The limit switches are wired as Normally Closed contacts (NC). Therefore, when the "Limit
Switch Plate" reaches the limit switch, the contact opens and the PLC receives "NO SIGNAL".
Installation and Maintenance - EBS Page - 15 - Amiad Filtration Systems (1997) Ltd.
PDS operation
The PDS constantly monitors the pressure differential between the inlet and outlet of the "EBS" filter.
When the PDS senses a preset value (usually 0.5 bar=7 PSI) there is a delay of three (3) seconds before the flush
cycle begins. At the end of the cleaning cycle, if the pressure differential signal remains, the filter will continue to
clean itself for 15 minutes before entering into malfunction mode.
Timer operation
Flush according to time is available through a built-in timer. It is possible to preset the intervals between flush
cycles, regardless of the pressure differential. The recommended default is between 6-8 hours.
In order to cancel the timer operation, simply turn the timer selector SW1 to its middle position.
"TEST" operation
The "TEST" button activates a manual self-cleaning cycle, in order to test the filter operation.
Continuous flushing
The filter flushes continuously regardless of pressure differential or time. It is recommended that this mode be used
for a limited duration only - in order to overcome extreme dirt load situations.
Malfunction modes
The system recognizes two malfunction modes: 1) Mechanical fault
2) Clogging fault (DP Fault).
Note: Pressing the RESET button or turning power off and then back on without performing the above-mentioned
instructions will NOT release the system from a fault condition!
Installation and Maintenance - EBS Page - 16 - Amiad Filtration Systems (1997) Ltd.
General information
1. When power is first turned on, the PLC will check the bottom limit switch to be sure it is "OPEN", if not the
motor will operate to move the "Limit Switch Plate" until it reaches the limit switch.
2. The flushing counter will operate at the end of each cleaning cycle. Reset the counter by pressing its red
button.
3. PAUSE: Bridging positions 6A and 6B on the terminal strip pauses the cleaning cycle immediately. This
function applies only for special applications. Please consult the manufacturer or an authorized dealer for
further information.
4. "END OF CYCLE" PULSE: (Output O/1, terminals 10 & 11)
A free potential output, which signals at the end of each flushing cycle for 5 seconds. With this pulse it is
possible to connect multiple controllers in a series to allow sequential flushing. In this case, connect terminals
10 & 11 to PDS inlet in the next controller of the series. If one of the filters in the series is in malfunction
mode the signal will be automatically transmitted to the next filter in line.
5. "FLUSHING ON" SIGNAL: (Output O/1 + Input I/9 = ON, terminals 10 & 11). This configuration allows
the integration of a downstream pressure regulating valve or peripheral pump operation during the flushing
cycle.
Output O/1 is activated one second before the beginning of the flushing cycle. This short delay allows a timer
and a relay (optional) to activate the PAUSE circuit (input I/6) for the duration required by the downstream
valve or the peripheral pump.
Both optional features of output O/1 may also be used for information transmitting to a remote control center.
NOTE: Extra features to the control panel are available according to specific requirements. These features must
be defined in advance.
Startup Procedure
1. Check and verify that wiring between the filter and the control panel is done according to the provided wiring
diagram.
2. Verify that the "Limit Switch Plate" is located halfway between the two limit switches and that the motor
protector (Over Load) is switched off.
3. Switch "ON" all circuit breakers (except the motor O.L.).
4. Set selector SW1 to the middle position (PD only).
5. Switch on the motor O.L. and watch the rotation direction of the motor. If the motor rotates counterclockwise
i.e. the suction scanner moves upward stop it immediately by turning the O.L. to the off position. Change the
motor direction by switching between two phases.
If the motor rotates clockwise i.e. the suction scanner moves downward let it continue until it reaches the lower
limit switch and stops.
6. Press the "TEST" push button and verify that the filter is functioning according to the above description.
7. Open the water supply and pressurize the system. It is highly recommended that first "wet" operation is done
with static pressure and no flow i.e. the outlet valve is open and the by-pass of the system is open.
8. Operate a flushing cycle by pressing the test push-button. Verify that everything is working properly as
described above.
9. Operate a flushing cycle by closing the 1/4" Manometer Valve of the PD switch for 5 seconds.
10. If everything is functioning as described, open the outlet valve of the filter, and gradually close the by-pass
valve.
11. Set T1 to 4 - 8 hours and turn selector SW1 to the upper position (PD & Time). Follow and monitor the
functioning of the filtration system, change T1 setting if required.
Installation and Maintenance - EBS Page - 17 - Amiad Filtration Systems (1997) Ltd.
WIRING DIAGRAM
Installation and Maintenance - EBS Page - 18 - Amiad Filtration Systems (1997) Ltd.
ELECTRICAL DIAGRAM (page 1 - power)
The following diagrams are for reference only. With any inquiry, please refer to the electrical diagrams inside the
control panel cabinet.
Installation and Maintenance - EBS Page - 19 - Amiad Filtration Systems (1997) Ltd.
ELECTRICAL DIAGRAM (page 2 - control)
Installation and Maintenance - EBS Page - 20 - Amiad Filtration Systems (1997) Ltd.