PRODUCT DATA

9 09 97 23 Elastomeric
Coatings
THOROLASTIC® A+
Algae-resistant, water-based smooth 100%
acrylic elastomeric waterproof coating

Description Features Benefits


Thorolastic® A+ is an algae-resistant, • Algae resistant Resists algae growth on the coating; suitable for
high-build, water-based, elastomeric, humid conditions
100% acrylic, waterproof coating. Its • Over 300% ultimate elongation Bridges dynamic cracks
resistance to algae growth makes it
• 98% elongation recovery Offers durable performance
appropriate for humid environments.
• Flexibility at very low temperatures Suitable for all climates
• Internally plasticized Retains flexibility for durable service
Yield
• Resistant to wind-driven rain Helps prevent water penetration into the substrate
50 – 100 ft2/gallon (1.2 – 2.4 m2/L)
per coat, depending on substrate • Breathable Allows water vapor to escape from the structure;
porosity and texture. prevents peeling and blistering
Theoretical film thicknesses are listed • Carbon-dioxide diffusion barrier Protects embedded steel from corrosion
on page 3. • Excellent color retention and UV resistance Long-term durability; resists color fading
Packaging • Recoatable Easy and cost-efficient to maintain
5 gallon (18.9 L) pails • VOC compliant Environmentally friendly
Color
Thorolastic® A+ is available in
4 bases (pastel, medium, ultra, Where to Use 2. High-pressure water blast (or abrasive blast on
hard, dense surfaces) surface to medium grit
and neutral) and 48 standard colors APPLICATION
sandpaper texture (reference ICRI guide 03732 SP 3).
through the Elements color program. • For protecting and decorating
Color formulations are available 3. Repair any holes, spalled and damaged concrete
LOCATION with appropriate BASF Construction Chemicals repair
through the electronic Thoro® Tint
Manual. Custom colors are available • Vertical materials. Remove any protruding concrete
upon request. For further information, • Exterior accessories and smooth out any irregularities.
please consult your local Thoro® • Above grade 4. Some stains may require chemical removal. Be
distributor or representative. sure to neutralize the compounds and rinse with
Texture SUBSTRATE clean water.
Smooth • Stucco 5. Remove any blisters or delaminated areas and
• Concrete structures sand edges to smooth rough areas and provide
Shelf Life
• Portland cement plaster transition to old paint areas.
18 months when properly stored.
• Brick and concrete masonry units (CMU) 6. Check adhesion of old paint using ASTM D 3359,
Storage measuring adhesion by Tape Method A.
Store in a clean, dry place away from • EIFS
7. Treat cracks greater than 1/32” with Patching
direct sunlight until ready for use. Compound 746 / 748. Treat cracks larger than 1/4”
Keep from freezing temperatures. How to Apply as expansion joints and fill with appropriate BASF
Surface Preparation Construction Chemicals sealant.
1. Surface should be clean and sound. Concrete
substrates should have a minimum 28 day cure and
be free of all bond-inhibiting contaminants.

15
THORO® PRODUCT DATA
THOROLASTIC® A+

Technical Data
Composition Test Data
Thorolastic® A+ contains water, acrylic emulsion, PROPERTY RESULTS TEST METHODS
fillers, and other proprietary ingredients.
Density, lbs/gal (kg/L) 11.2 – 12.2 (1.34 – 1.46) ASTM D 1475
Solids*, % ASTM D 5201
By weight 64.2
By volume 50
Viscosity, KU 127 – 135 ASTM D 562 (Stormer)
VOC content, lbs/gal (g/L) 0.32 – 0.42 (38 – 50) ASTM D 3960
* Value for white.

THOROLASTIC® A+ APPLIED AT 16 MILS DFT

PROPERTY RESULTS TEST METHODS

Anti-algae resistance Passed Singapore Test, SS 345: 1990


Ultimate elongation, % 344 ASTM D 412
Elongation recovery, % ASTM D 412
After 10 minutes 96.9
After 24 hours 98.4
Ultimate tensile strength, 220 (1.5) ASTM D 412
psi (MPa)
Crack bridging, mils (mm) PR EN 1062-7
-77° F (-60° C) 12 (0.3)
32° F (0° C) 19.5 (0.5)
73° F (23° C) 27.5 (0.7)
Flexibility, in (mm) mandrel, 1/8 (3) ASTM D 522
at -30° F (-34° C)
Pull-off strength adhesion, 210 (1.4) ASTM D 4541
psi (MPa)
Wind-driven rain Passes TT-C-555B
Water-vapor permeance, perms 10 ASTM D 1653
Carbon-dioxide diffusion, PR EN 1062-6
R (equivalent air-layer thickness),
ft (m) 263 (80)
Sc (equivalent concrete thickness)
in (cm) 8 (20)
Accelerated weathering, Passes ASTM G 23, Type D
5,000 hrs
Freeze/thaw resistance, Passes ASTM C 67
60 cycles
Salt spray resistance, Passes ASTM B 117
300 hrs
Mildew resistance No growth ASTM D 3273 / 3274
Test results are averages obtained under laboratory conditions. Reasonable variations can be expected.

15.2
THORO® PRODUCT DATA
THOROLASTIC® A+

Theoretical Film Thicknesses


SMOOTH FINE COARSE
COVERAGE RATE WET MILS DRY MILS WET MILS DRY MILS WET MILS DRY MILS
FT2/GAL (M2/L) (MICRONS) (MICRONS) (MICRONS) (MICRONS) (MICRONS) (MICRONS)

50 (4.6) 32 (813) 16 (406) 32 (813) 18 (457) 32 (813) 19 (483)


80 (7.4) 20 (508) 10 (254) 20 (508) 11 (279) 20 (508) 12 (305)
100 (9.3) 16 (406) 8 (203) 16 (406) 9 (229) 16 (406) 9 (229)
Actual DFT to achieve the stated performance properties is 16 mils.

CONCRETE EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) Mixing


1. New concrete must be cured a minimum of 1. Refasten or re-adhere any delaminated or loose 1. Mechanically mix Thorolastic® A+ at slow speed
28 days before application. expanded polystyrene (EPS) insulation following with a drill and mixing paddle to ensure uniform
2. In addition to removing laitance and all manufacturer’s approved methods. color and aggregate disbursement, and to minimize
contaminants, remove all form-release agents 2. Replace or patch any missing or damaged EPS to air entrapment.
or previously applied sealers. its original condition. 2. In multi-pail applications, mix the contents of
3. Remove all form tie wires and repair holes, small 3. Finish with a trowel acrylic finish to match and each new pail into the partially used pail to ensure
voids, and spalls using the appropriate repair blend with the existing texture. color consistency and smooth transitions from pail to
product. 4. Allow repaired areas to fully cure. pail.
4. Abrasive blast very slick, dense concrete surfaces 5. Refer to the EIFS manufacturer’s product data Application
or prime with Thoro® CM Primer (see Form No. sheets for appropriate repair and other procedures. 1. Pretreat all cracks as detailed in the crack
1019088). preparation section.
EXISTING ACRYLIC COATINGS
5. To check for proper adhesion, a test area is 2. Apply Thorolastic® A+ in 2 coats by brush, spray,
recommended. 1. Sand or grind the edges of any remaining coating
roller, or spray-and-backroll.
to ensure adhesion and a smooth transition with the
BRICK AND CONCRETE MASONRY UNITS (CMU) new material. Sand the edges of the area to a 3. Apply Thorolastic® in 2 coats to achieve a total
1. All new CMU should be laid true and fully cured featheredge. dry-film thickness (DFT) of 16 – 20 mils.
to full load-bearing capacity. 2. Wash down and allow to completely dry. 4. Proper wet-film thickness (WFT) must be
2. Remove all mortar splatter and excess mortar maintained during application to ensure the
3. Chalky surfaces should be primed with Thoro®
before coating application. performance characteristics desired (see
Primer 2K.
coverage rates section).
3. Repoint or fill all voids with the appropriate BASF
CRACK PREPARATION AND PRETREATMENT 5. Always work to a natural break and maintain a
patching product.
1. Locate and identify all cracks. wet edge during application.
4. New CMU must have a base coat of Thoro Block®

Filler (see Form No. 1019087) or Thoro® Intermix. 2. Clean and detail static cracks larger than 1/32” 6. The objective is to obtain a pinhole-free
(0.8 mm) in width and fill with Patching Compound consistent film build on all treated surfaces.
PLASTER AND STUCCO 746 / 748 (see Form No. 1017938)
ROLLER
1. Clean the surface and remove all debonded or 3. If using a product other than Patching Compound
delaminated plaster or stucco and repair with 1. Use a quality 3/4 – 1-1/4" (19 – 32 mm) nap
746 / 748, always apply a test application in a low
Thoroseal® Plaster Mix (see Form No. 1019908) roller cover (lamb’s wool preferred).
visibility area to ensure compatibility with the
modified with Acryl 60® (see Form No. 1019073). patching products. 2. Completely saturate the roller and keep it loaded
2. Allow new plaster or stucco to cure a minimum with the coating to build the required mils. Never dry
4. For moving cracks larger than 1/4 by 1/4"
of 14 days at 70° F (21° C) and 50% relative roll.
(6 by 6 mm), use an internally plasticized
humidity or until the pH level has reached 10. Allow polyurethane sealant. Consult with the sealant 3. Roll the coating in a consistent fanlike pattern to
longer cure times if temperatures are lower or manufacturer to ensure compatibility. achieve uniform mil thickness.
relative humidity is higher. 4. Cross roll to achieve uniform thickness and
5. Always apply a test application to an
3. After cleaning and profiling, prime chalky inconspicuous location to ensure compatibility maintain a wet edge. Backroll in one direction as
surfaces with Thoro® Primer 2K (see Form No. and aesthetic approval. stroke variations may result in uneven color and
1019090) and allow primer to dry. texture.

15.3
THORO® PRODUCT DATA
THOROLASTIC® A+

BRUSH For Best Performance Health and Safety


1. Application by brush is recommended only for • Protect all plants and vegetation from overspray. THOROLASTIC® A+
small inaccessible areas, e.g., on touch-ups.
• Do not use on interior applications, undersides of Caution
2. Use a nylon brush only. balconies, soffits, below-grade applications, or for Thorolastic® A+ contains ethylene glycol, zinc oxide
SPRAY immersion service. and crystalline quartz silica.
1. Large airless equipment is required. Contact • Protect product from freezing. Risks
Technical Service for recommendations. • Do not apply to frozen or frost-covered surfaces May cause skin, eye or respiratory irritation.
2. Backrolling after spray application is or at temperatures (substrate or ambient) at or Ingestion may cause irritation. Repeated ingestion
recommended. below 40° F (4° C) or when temperatures are may cause kidney damage.
expected to drop below 40° F (4° C) within
Drying Time Precautions
24 hours after application.
1. Drying time to touch is 6 hours at 70° F KEEP OUT OF THE REACH OF CHILDREN. Avoid
• Do not apply if rain is expected within 24 hours
(21° C) and 50% relative humidity when applied contact with eyes, skin and clothing. Wash
of application.
at 18 – 20 mils thoroughly after handling. Keep container closed
• Do not use where there may be hydrostatic water when not in use. DO NOT take internally. Use only
2. Recoat in a minimum of 12 – 24 hours.
transfer from the backside of the substrate. with adequate ventilation. Use impervious gloves, eye
3. Thorolastic® A+ requires ultraviolet (UV) light to
• Do not apply to improperly sealed substrates that protection and if the TLV is exceeded or used
cure.
are subject to rising dampness or migrating in a poorly ventilated area, use NIOSH/ MSHA
4. Drying time will be significantly extended in cool moisture. approved respiratory protection in accordance with
or damp weather. applicable federal, state and local regulations.
• Do not apply Thorolastic® A+ to sloped (less than
5. Protect the freshly applied Thorolastic® A+ 60°) or horizontal surfaces. First Aid
coating from rain and condensation for a minimum
• Application of nonelastomeric topcoats could In case of eye contact, flush thoroughly with water
of 24 hours.
reduce the performance properties of for at least 15 minutes. In case of skin contact, wash
Clean Up Thorolastic® A+. affected areas with soap and water. If irritation
Clean all tools and equipment with soap and water • Apply a 4 by 4 ft (1.2 by 1.2 m) test area to persists, SEEK MEDICAL ATTENTION. Remove and
immediately after use. Clean any splatters or spills verify acceptable color, texture, and adhesion wash contaminated clothing. If inhalation causes
with water before material dries. Once dried, before proceeding with any project. The test physical discomfort, remove to fresh air. If discomfort
Thorolastic® A+ will be difficult to remove and method for measuring adhesion is ASTM D 3359, persists or any breathing difficulty occurs or if
may require mechanical removal. Measuring Adhesion by Tape, Method A. On the 0 swallowed, SEEK IMMEDIATE MEDICAL ATTENTION.
– 5 scale, a minimum adhesion rating of 4A is Refer to Material Safety Data Sheet (MSDS) for
required. further information.
• Make certain the most current versions of Proposition 65
product data sheet and MSDS are being used; This product contains material listed by the state of
call Customer Service (1-800-433-9517) to California as known to cause cancer, birth defects, or
verify the most current version. other reproductive harm.
• Proper application is the responsibility of VOC Content
the user. Field visits by BASF personnel
0.32 – 0.63 lbs/gal or 38 – 75 g/L, less water and
are for the purpose of making technical
exempt solvents
recommendations only and not for supervising
or providing quality control on the jobsite.
For medical emergencies only,
call ChemTrec (1-800-424-9300).

BASF Corporation LIMITED WARRANTY NOTICE Every reasonable effort is made to apply BASF exacting standards both in the manufacture of our products and in the information which we issue concerning these products and their use. We
warrant our products to be of good quality and will replace or, at our election, refund the purchase price of any products proved defective. Satisfactory results depend not only upon quality products, but also upon many factors
Building Systems beyond our control. Therefore, except for such replacement or refund, BASF MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR
MERCHANTABILITY, RESPECTING ITS PRODUCTS, and BASF shall have no other liability with respect thereto. Any claim regarding product defect must be received in writing within one (1) year from the date of shipment. No claim
will be considered without such written notice or after the specified time interval. User shall determine the suitability of the products for the intended use and assume all risks and liability in connection therewith. Any
889 Valley Park Drive authorized change in the printed recommendations concerning the use of our products must bear the signature of the BASF Technical Manager.
Shakopee, MN, 55379 This information and all further technical advice are based on BASF’s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and
advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES
OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF reserves
www.BuildingSystems.BASF.com the right to make any changes according to technological progress or further developments. It is the customer’s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein
should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation,
Customer Service 800-433-9517 nor an endorsement of any product and does not imply that similar products could not be used.
Form No. 1019111 01/12 © 2012 BASF
Technical Service 800-243-6739 For professional use only. Not for sale to or use by the general public. Printed on recycled paper including 10% post-consumer fiber. Printed in U.S.A.

15.4

You might also like