SINGLE SAMPLING PLAN FOR NORMAL INSPECTION, ANSI/ASQ STANDARD Z1.4-2003
SAMPLE SIZE CODE LETTERS General Inspection Levels Special Inspection Levels Lot Size I II III S1 S2 S3 S4 2 to 8 A A B A A A A 9 to 15 A B C A A A A 16 to 25 B C D A A B B 26 to 50 C D E A B B C 51 to 90 C E F B B C C 91 to 150 D F G B B C D 151 to 280 E G H B C D E 281 to 500 F H J B C D E 501 to 1200 G J K C C E F 1201 to 3200 H K L C D E G 3201 to 10000 J L M C D F G 10001 to 35000 K M N C D F H 35001 to 150000 L N P D E G J 150001 to 500000 M P Q D E G J 500001 and over N Q R D E H K
Acceptable Quality Levels (Normal Inspection)
Sample Size Sample 0.065 0.1 0.15 0.25 0.4 0.65 1 1.5 2.5 4 6.5 10 15 Code Letter Size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A 2 0 1 B 3 0 1 1 2 C 5 0 1 1 2 2 3 D 8 0 1 1 2 2 3 3 4 E 13 0 1 1 2 2 3 3 4 5 6 F 20 0 1 1 2 2 3 3 4 5 6 7 8 G 32 0 1 1 2 2 3 3 4 5 6 7 8 10 11 H 50 0 1 1 2 2 3 3 4 5 6 7 8 10 11 14 15 J 80 0 1 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 K 125 0 1 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 L 200 0 1 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 M 315 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 N 500 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 P 800 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 Q 1250 2 3 3 4 5 6 7 8 10 11 14 15 21 22 R 2000 3 4 5 6 7 8 10 11 14 15 21 22 = Use first sampling plan below the arrow. If sample size equals, or exceeds, lot or batch size, do 100% inspection. = Use first sampling plan above the arrow.