MAINTENANCE/OVERHAUL
MANUAL
AUTOPILOT
ACCESSORIES MANUAL
KA 117 KA 185
KA 142 KA 285
KA 118 KC 290/292
Ke 291
RS LRT ER
MANUAL NUMBER 006-5556-04
REVISION 4
Ist PRINTING APRIL, 1976
4
KING RADIO CORPORATION.
400 NORTH ROGERS ROAD OLATHE, KANSAS, U.S.A.KING
Ke 290/292
NoDE CONTROLLERS
section vi
maintenance
6.1 GENERAL
This section contains information relative to the testing disassembly and troubleshooting of the KC
290/292 Node Controller.
6.2 TEST AND ALIGNMENT
The following is procedure to determine if the performance of the K¢ 290/292 is satisfactory. If it ts
not, ‘the alignment’ procedures are given in order to bring the unit up to its minimus performance
specifications. It is important that this be done as far as possible before troubleshooting iz
atteapted.
6.2.1 REQUIRED TEST EQUIPMENT
DESCRIPTION CHARACTERISTICS REQUIRED REPRESENTATIVE TYPE
King KTS 151 Component Ken 971508000,
Bench Tester
Multimeter Capable of measuring AC, DC Fluke 20008
volts,
Oscilloscope Vertical sensitivity 10mv/ Telequipment 067
division
6.2.2 KTS 151 BENCH TESTER
The KTS 151 has been designed to bench check a number of components in the KFC 200 Flight Control System.
The KC 290/292 Mode Controller is included in this group.
The tester is constructed around a main frame which contains the D¢ and AC signal sources, Lagps which
are used to annunciate modes and special situations, and the pin outs for the KC 290/292. Figure 6-1
Shows the basic connection of the KC 290/292 to the KTS 151 Bench Tester. Portions of the tester used
with the KC 290/292 are shaded in.
Further information concerning the KTS 151 Flight Control System Set can be found in the KTS 151
Maintenance Manual.
6.2.3 TEST PROCEDURES USING THE KTS 151
6.2.3.1 General
This section cont
Section 6.4.
1s the test procedures to be used in conjunction with the troubleshooting chart in
The procedures are divided into sections and are herein presented for quick access to specific tests.
Ke 290/292 TEST PROCEDURE INDEX
6.2.5.2 Initial Setup Procedure
6.2.3.3 Mechanical Test
6.2.3.6 Holding Coit Resistance
6.2.3.5 Mode Selector Switch Test
6.2.3.6 AP LO Voltage Test
6.2.3.7 Holding coil Current (14v
Rev. 3, March, 1982
mas" Page 6-1KING
ke 290/292.
(MODE CONTROLLERS
6.23.8 Pitch Adjust Pot
6.2.3.9 Roll Adjust Pot
6.2,3.10 14v Panel Lighting
6.2.3.11 28V Lighting and AP Engage Holding Torque
6.2.3.12 Servo Effort Meter (KC 292)
Section 6.2.3.2 contains the procedures necessary to prepare the KTS 151 tester and the KC 290/292 unit
for troubleshooting. The section containing the KC 290/292 unit preparation should be completed each
tine a new unit is connected to the tester.
‘The remaining sections of 6.2.3 contain the procedures for testing the KC 290/292. Prior to the start of
Gach procedure, all test set controls should be positioned in accordance with Section 6.2.5.2. The only
exception is Test Set Power unich may be Left on if another procedure has just been completed. When
these instructions are followed, any test procedure aay be run independently without concern for the
order of procedures previously run.
6.2.3.2 Initial Setup Procedure
a. Test Set Initialization
(1) Place the Power Selector switch to the OFF position.
(2) Remove the KC 290/292 test cable. ALL other cables may remain stored inside the
tester.
(5) Place all pushbutton controls in the Out position on the KTS 151 tester.
(4) connect the 9C power supply to the KTS 151 tester input power jacks.
‘WARNING
DO NOT CONNECT MORE THAN ONE UNIT TO THE KTS 151 AT ANY TIRE,
Ke 2907292 Initialization
(1) Connect the KE 290/292 to the test panel.
fe. Test Set Pover ON
CAUTION
THE SERVO EFFORT METER SWITCH MUST BE ENGAGED AT ALL TIMES WHEN A
Ke 292 NODE CONTROLLER TS BEING TESTED TO PREVENT DAMAGE TO THE
NETER MOVEMENT.
(1) Set wo the KTS 151 Tester as follows:
Power Selector OFF
Servo Effort Meter - Eng. with KC 292 unit (See CAUTION
Servo Effort Neter ~ OFF with KC 290 unit
ALL other pushbutton switches OFF
(2) Adjust the INPUT POWER +14/428VDC to +14vDC.
(3) connect the KE 290/292 cable from the tester to the mating connectors on the
Ke 290/292.
(4) Rotate the Power Selector switch to 14.
Rev. 3, March, 1982
mda ’s Page 6-2widens vamos 00
um aasn 435 1534
SINAN SVE 30SKING
ke 290/292
MODE CONTROLLERS
6.2.3.3 Mechanical Test
ALL pushbutton switches shall be adjusted to prevent binding on the front bezel or frame.
the trim and AP Engage ewitehes shall be free to travel from stop to stop without binding or interference
from any component, regardless of orientation of the unit.
6.2.3.4 Holding Coil Resistance
Rotate the Power Selector switch to OFF. with an ohmmeter on the 200 ohm scale, measure the resistance
Between pin 6, J1 KC 290 (OLK) and pin 6, J2 Ke 290 (RED). Tt shall be 150 + 12 ohms.
Measure between pin 6, Jt KC 290 (RED) and pin 3, J1 KC 290 (BLK. Tt shall be 150 + 7.5 ohms.
Rotate the POWER SELECTOR switch to +14vDC, ALL indicators on the KTS 151 shall be off.
6.2.5.5 Node Selector Switch Tests
Sequentiatly depress each of the node selector switches. The indicator for that switch shall Light.
ReLease the switch and its Lamp shall go out.
NOTE
IF THE Ke 290/291 sw SHORT DETECTED SWITCH LIGHTS AT ANY TIE
DURING TESTING, STOP THE TEST UNTIL THE DEFECTIVE SWITCH OR
SWITCHES ARE REPLACED. TO RESET KC 290/291 SW SHORT DETECTED
‘SWITCH, ENGAGE AND THEN RELEASE THE SWITCH.
yess the Trim Up switch and its indicator shall Light. Measure 15 $ 1.0VDC between pin A, J1 KC 290
(GLK) and pin 1, 42 KC 290 (RED). Release the Trim UD switch and its Camp shall go out.
Press the Trim ON switch and its indicator shall Light. Measure ~15 + 1.0vDC between pin A, J1 KC 290
(BLK) and pin 1, J2 KC 290 (RED). Release the Trim ON suitch and its Lamp shall go out.
Engage the SWITCH GND POLE CHECK switch. The following Laps shall Light:
Wo, NAV, APPR, BC, ALT, FD (KC 290 units only?
Sequentially depress each of the mode selector switches. The indicator for that switch shall go out.
Release the switch and its lamp shall Light. ‘
Raise the AP switch and the AP Engage indicator shall Light and the KC 295 AP Clutch Engage indicator
Shall Light. Engage and release the AP Disc switeh. AP Engage indicator shall go out and the KC 295 AP
Clutch engage indicator shall go out. The AP switch shall disengage.
Press the TEST switch and its indicator shall Light. Release the TEST switch and its indicator shall go
Dut. Return the SWITCH GND POLE CHECK switch to the OFF position.
Engage the AP switch. The AP switch shall remain engaged. The AP Engage and the KC 295 AP Clutch Engage
shale Light.
Sequentially depress, then release, each of the mode selector switches. The corresponding Lamps shall
(igre and then go out. Press, then release, the TRIN UP, and TRIN ON switches. The corresponding
indicator shall Light up, then go out. The AP switch shall remain engaged.
6.2.5.6 §P LO Voltage Test
Engage the AP ENG switch,
Decrease the *14VDC input power to +11VDC. The AP switch shall remain engaged. Increase the +14vDC
input power to +14VDC.
Rev. 3, March, 1982
wn04e"s Page 6KING
ke 290/292.
(MODE CONTROLLERS.
6.2.3.7 Holding Coil current *14v0e
Connect a DC voltmeter across METER HI/LO test jacks. Rotate the MASTER SELECTOR switch to MISC TP
Current)» Rotate the MISC SELECTOR svitch to KC 290 HOLDING COIL (current). Engage the AP switch. The
meter snail read 90 + T2mVDC. Measure the force required to disengage the AP switch. [t shall be not
less than 8 oz, or wore than 2Ooz. (This test to be performed only after the AP switch has been engaged
for one minute)»
6.2.3.8 Piten Adjust Pot
Rotate the pitch adjust pot (pot nearest trim switch? Ci
With the voltmeter on the 20UDC scale measure between pin A, J2°KC 290 (RED? and pin'A, J1 KC 290 (ALK.
fe shall read #15 4 1.0VDC.
Rotate the pitch adjust pot CCH. With the voltmeter on the 2OVDC scale measure between pin A, J2 KC 290
(RED) and pin A, J1 KC 290 (BLK). It shall read -15 + 1.0vDC.
Center the pitch adjust pot. The meter shall read 0.0 + 0,100VDC between pin A, J2 KC 290 (RED) and pin
A, J1 KG 290 (BLK.
6.2.3.9 Roll Adjust Pot
Rotate the roll adjust pot (pot nearest AP sutich) CU.
With ise voltmeter on the 20VDC scale measure between pin F, J2 KC 290 (RED) and pin A, J1 KC 290 (BLK).
Te shall read “15 + 1.0vDe.
Rotate the roll adjust pot CCM. With the voltmeter on the 20VDC scale measure between pin F, J2 KC 290
(RED) and pin A, J1-KC 290 (BLK), It shall read +15 + 1.0vDC.
Center the roll adjust pot. The meter shall read 0.0 + 0,100VDC between pin F, 31 KE 290 (RED) and pin
Ay JT KC 290 (BLK).
6.2.3.10 Panel Lighting
Place a hood over the KC 290/292. The panel Lamp shall be Lit evenly.
6.2.5-11 28V Lighting and AP Engage Holding Torque Tests
Rotate the POWER SELECTOR switch to the OFF position, Increase the INPUT POWER +16/+28VDE to +28VDC.
Rotate the POWER SELECTOR switch to the *28V position. The panel Lamps shall be Lit evenly.
Allow one minute warm-up time before conducting this test. Connect a OC voltmeter across METER HI/LO
test jacks. Rotate the Master Selector switch to MISC TP (Current), Rotate the MISC Selector switch to
KE 290 HOLDING COIL Current). Engage the AP switch. The AP ENGAGE and the KC 295 AP CLUTCH ENGAGE
{ndicators shall Light. The meter shall read 90 + 12AVOC. Neasure the force required to disengage the
Ap awiteh, It shall be not Less than B oz, and not more than 20 02.
6.2.5.12 Servo Effort Neter
(this test is for KC 292 units only?
Rotate the SERVO EFFORT ADJUST pot CM. The pointer shall move soothly to its lower stop. Rotate the
Servo EFFORT ADJUST pot CCH. The pointer shall move smoothly to its upper stop.
6.2.3.13 Autopilot Disconnect Alerter Test (-O1 units only)
connect a 5-1Kohm resistor from the KC 290, J1, pin D to J2, pin C on the KTS 151 KC 290 pinouts.
connect 2 0C voltmeter from KC 290, J1, pin D (+) to pin A (=). The voltmeter should read +15 + 1vDC.
Life the A/P engage switch on the KC 290/292 and leave it engaged for 3 seconds. disengage the A/P
langage switch. The +15 + 1VOC from KC 290, J1, pin D (+) to pin A (~) should drop to 0 + 1V0C and remain
there for 24 .5 seconds. After 2 + .5 seconds, the voltage will return to H15'4 1VoCy R202 in the KC
2p0/292 may be adjusted for the correct 2 + .5 second tine. Remove the voltmeter and the 5.1Kohe
resistor.
Rev. 3, March, 1982
m0044°5 Page 6-6