FWC-Catalogue
FWC-Catalogue
Digit
1-3 FWC: Chilled Water Cassette Unit (4-Way)
Digit
4-6 Nominal Air Flow, CFM
003 = 300 CFM
004 = 400 CFM
005 = 500 CFM
006 = 600 CFM
008 = 750 CFM
009 = 850 CFM
010 = 950 CFM
012 = 1200 CFM
015 = 1500 CFM
Digit 7 Unit Type
2=2-pipe
4=4-pipe
Digit 8 Electric Heater
N=None
A=E-heater Equipped
Digit 9 Voltage / Phase / Hertz
1=220-240V /1Ph / 50Hz
2=220-240V/ 1Ph / 60Hz
Digit
10 Thermostat Options
A=Remote Controller
B=Wall Wired Controller
Digit
11 Service Code
A=Version A
Digit
12 Region
B=Export
General Data / Specifications (50Hz & 60Hz)
2 pipe 003 004 005
3
m /h 510 680 850
High
CFM 300 400 500
3
m /h 440 580 730
Air Volume Med
CFM 260 340 430
3
m /h 360 480 600
Low
CFM 210 280 350
Cooling Capacity (Hi/Med/Lo) W 3000 3700 4500
Heating Capacity (Hi/Med/Lo) W 4000 5100 6000
Electrical Auxiliary Heater (EAH) W 1000 1000 1000
Power Input W 50 70 95
Noise (Hi/Med/Lo) dB(A) 36/33/28 42/39/32 45/42/34
Water Flow l/min 8.7 10.7 12.9
Water Pressure Drop kPa 14 15 16
Net Dimension (W×H×D) mm 647×50×647
Net Weight kg 3
Panel
Packing Size (W×H×D) mm 715×123×715
Gross Weight kg 5
Net Dimension (W×H×D) mm 575×261×575
Net Weight (with EAH) kg 17.5
Indoor Unit
Packing Size (W×H×D) mm 655×290×655
Gross Weight kg 21.5
Water-inlet pipe Inch RC3/4"
Pipe Connection Water-outlet pipe Inch RC3/4"
Drain pipe mm ODΦ25
Note:
1. The data is the performance in high speed with relevant static pressure.
2. Cooling Conditions: Entering water 7°C, temperature rise 5°C, entering air 27°C DB/19°CWB.
Heating Conditions: Entering water 50°C, entering air 20°C, same water flow as cooling conditions.
3. Noise is tested in full-anechoic test room.
2 pipe 006 008 009
3
m /h 1000 1250 1400
High
CFM 590 740 820
3
m /h 850 1060 1190
Air Volume Med
CFM 500 620 700
3
m /h 720 900 1010
Low
CFM 420 530 590
Cooling Capacity (Hi/Med/Lo) W 5700 7000 7270
Heating Capacity (Hi/Med/Lo) W 9660 11550 12420
Electrical Auxiliary Heater (EAH) W 2100 2100 2850
Power Input W 125 130 150
Noise (Hi/Med/Lo) dB(A) 45/41/36 46/42/37 47/43/38
Water Flow l/min 16.4 20 20.8
Water Pressure Drop kPa 23.8 25.2 27
Net Dimension (W×H×D) mm 950×45×950
Net Weight kg 6
Panel
Packing Size (W×H×D) mm 1035×90×1035
Gross Weight kg 9
Net Dimension (W×H×D) mm 840×230×840 840×230×840 840×300×840
Net Weight (without/with EAH) kg 25/27 25/27 30.5/33
Indoor Unit
Packing Size (W×H×D) mm 900×237×900 900×237×900 900×307×900
Gross Weight (without/with EAH) kg 30/32 30/32 36.2/39
Water-inlet pipe Inch RC3/4"
Pipe
Water-outlet pipe Inch RC3/4"
Connection
Drain pipe mm ODΦ32
Note:
1. The data is the performance in high speed with relevant static pressure.
2. Cooling Conditions: Entering water 7°C, temperature rise 5°C, entering air 27°C DB/19°CWB.
Heating Conditions: Entering water 50°C, entering air 20°C, same water flow as cooling conditions.
3. Noise is tested in full-anechoic test room.
2 pipe 010 012 015
3
m /h 1600 2000 2550
High
CFM 940 1180 1500
3
m /h 1360 1700 2170
Air Volume Med
CFM 800 1000 1280
3
m /h 1150 1440 1840
Low
CFM 680 850 1080
Cooling Capacity (Hi/Med/Lo) W 8220 10390 12900
Heating Capacity (Hi/Med/Lo) W 13850 17580 17600
Electrical Auxiliary Heater (EAH) W 2850 2850 /
Power Input W 155 190 190
Noise (Hi/Med/Lo) dB(A) 48/44/39 49/45/40 50/46/41
Water Flow l/min 23.6 29.8 36.9
Water Pressure Drop kPa 31.2 44 40
Net Dimension (W×H×D) mm 950×45×950
Net Weight kg 6
Panel
Packing Size (W×H×D) mm 1035×90×1035
Gross Weight kg 9
Net Dimension (W×H×D) mm 840×300×840
Net Weight (without/with EAH) kg 30.5/33 30.5/33 35
Indoor Unit
Packing Size (W×H×D) mm 900×307×900
Gross Weight (without/with EAH) kg 36.2/39 36.2/39 41
Water-inlet pipe Inch RC3/4"
Pipe
Water-outlet pipe Inch RC3/4"
Connection
Drain pipe mm ODΦ32
Note:
1. The data is the performance in high speed with relevant static pressure.
2. Cooling Conditions: Entering water 7°C, temperature rise 5°C, entering air 27°C DB/19°CWB.
Heating Conditions: Entering water 50°C, entering air 20°C, same water flow as cooling conditions.
3. Noise is tested in full-anechoic test room.
4 pipe 003 004 005
3
m /h 510 680 850
High
CFM 300 400 500
3
m /h 440 580 730
Air Volume Med
CFM 260 340 430
3
m /h 360 480 600
Low
CFM 210 280 350
Cooling Capacity W 2500 2900 3500
Heating Capacity W 3700 4600 5100
Electrical Auxiliary Heater (EAH) W 1000 1000 1000
Power Input W 50 70 95
Noise(Hi/Med/Lo) dB(A) 36/33/28 42/39/32 45/42/34
Cooling l/min 7.2 8.4 10
Water Flow
Heating l/min 5.3 6.6 7.3
Packing weight kg 41
Packing weight kg 9
Note:
1. The data is the performance in high speed.
2. Cooling Conditions: Entering Water 7°C, Temperature Rise 5°C, Entering Air Temperature 27°C DB,19°CWB.
Heating Conditions: Entering Water 70°C, Entering/leaving temperature difference is 10°C,enter air temperature 20°C
3. Noise level is tested in semi-anechoic room
4 pipe 010 012 015
3
m /h 1720 1860 2100
High speed
CFM 1010 1090 1230
3
m /h 1200 1300 1470
Air volume Mid speed
CFM 700 760 860
3
m /h 1030 1110 1260
Low speed
CFM 610 650 740
Cooling capacity W 6700 9280 10580
Heating capacity W 8670 11650 12620
Electrical Auxiliary Heater (EAH) W 2700 2700 /
Power input W 205 197 234
Sound level (Hi/Med/Lo) dB(A) 47/38/32 48/40/34 50/42/36
Water flow l/min 19.2 26.6 30.3
Cooling
Water pressure drop kPa 22 32 38
Water flow l/min 12.4 16.7 18.1
Heating
Water pressure drop kPa 42 57 61
Packing weight kg 41 44 44
Packing weight kg 9
Note:
1. The data is the performance in high speed.
2. Cooling Conditions: Entering Water 7°C, Temperature Rise 5°C, Entering Air Temperature 27°C DB,19°CWB.
Heating Conditions: Entering Water 70°C, Entering/leaving temperature difference is 10°C,enter air temperature
20°C
3. Noise level is tested in semi-anechoic room
Dimension (50Hz & 60Hz)
FWC003~005 (2 pipe)
FWC006~015 (2 pipe)
FWC003~005 (4 pipe)
FWC006~015 (4 pipe)
Controllers
Wired Controller
Function
◎ Working Voltage: DC5V.
◎ Working Environment:
Temperature: -15~43°C
Relative Humidity: 40%~90%.
Temperature Controlling Range: 17~30°C.
Temperature Controlling Precision: ±1°C.
◎ Big LCD display screen.
◎ Mode setting: auto/cool/heat/dry/fan.
◎ Fan speed selection: auto/high/medium/low.
◎ Economic operation mode/time setting/temp. setting.
◎ ON/OFF mode setting.
Remote Controller
FWC003~005 FWC006~015
Function Function
◎ Mode selection: Auto, Cool, Dry, Heat, Fan only ◎ Mode selection: Auto, Cool, Dry, Heat, Fan only
◎ Temp. setting range: 17 ℃ to 30 ℃ ◎ Temp. setting range: 17 ℃ to 30 ℃
◎ Daily Timer setting ◎ Daily Timer setting
◎ Louver swing ◎ Louver AUTO-Swing( vertical and horizontal)
◎ Fan speed control: H/M/L/Auto ◎ Fan speed control: H/M/L/Auto
◎ Economic operation button ◎ Economic operation button
Wiring Diagram(50Hz & 60Hz)
FWC003~005 (2 pipe)
FWC006~015(2 pipe)
FWC003~005 (4 pipe)
FWC006~015(4 pipe)