Color Mapping 32 Software

Instruction Manual
Version No. 1.24

TOPCON Medical Systems, Inc.

Page 0 TOPCON Corporation


Introduction
Thank you very much for purchasing the TOPCON Color Mapping 32.

Please read this Instruction Manual with care before using this Software.
A good understanding and working knowledge of this software will guarantee
your satisfaction for many years to come.
Keep this Manual at hand for further reference.

Precautions

• TOPCON has the copyright of the Software, "Color Mapping 32".


• Reproduction and copying of the software and the Instruction manual, in
whole or in part, without our permission is strictly prohibited.
• As a rule, one set of the software must be purchased for each PC installed.
• For the handling procedures of KR-7000P/ KR-7100P/ KR-8000PA/ KR-
8100PA/ KR-8100P, refer to its instruction manual.
• This Instruction Manual does not describe details about the handling
procedures of PC and Microsoft Windows. This Instruction Manual is
made on an assumption that the user already has knowledge about the PC
and Microsoft Windows.
• For the handling procedures of PC and Microsoft Windows, refer to the
pertaining manuals.
• Incorrect handling or operation of the PC may damage it or its software.
• We shall not take any responsibility for the effects of or as a result of
using the Instruction Manual and Software.
• Specifications of the Software and descriptions of the Instruction Manual
are subject to change without prior notice.

KR-7000P/ KR-7100P/ KR-8000PA/ KR-8100PA/ KR-8100P, Color Mapping 32, and


CV Power Supply Unit are trademarks of the TOPCON Corporation.
Microsoft, MS, and MS-DOS are registered trademarks, and Windows is a trademark of
Microsoft Corporation.
PC-DOS is a registered trademark of International Business Machines Corporation

Page 1 TOPCON Corporation


NOTATIONS
The following notations are used in the Instruction Manual.

MENU, COMMAND AND DIALOG BOX

Expression Description
[File]menu Menu name is expressed in [ ].
[Open] of [File] menu Command name is expressed in [ ] with menu name in which it
is included.
[Open File]dialog box Dialog box name displayed on title bar is expressed in [ ].
[OK] Command button name is expressed in [ ].

MOUSE OPERATION

Expression Description
Point Move mouse and bring mouse pointer onto object of operation.
Click Press and release mouse button.
Double-click Click mouse button twice.
Drag Press and move mouse button and release it at final position.

KEY OPERATION

Expression Description
Enter Key name is expressed with bold type.
Shift+F1 Plus symbol (+) means to press multiple keys; for example,
Shift+F1 means to press Shift key and F1 key.
Direction key Generic name of →, ←, ↑ and ↓ keys.

OTHER EXPRESSIONS

Expression Description
Memo Gives hints for operation.

Page 2 TOPCON Corporation


SAFETY PRECATIONS

CAUTION

Items Prevention items Page


Note that the necessary memory capacity and hard disk capacity
7
may differ for each PC.
Contact Lens Simulation
Physician can not use report data for lens prescription without
43
their personal validation.

Contents of the package

The following are standard accessories. Make sure that all these items are attached (quantity).

CD-ROM (1)
RS232C Cable (1)
(D-sub9P-DIN8P)

Instruction Manual (1)

Page 3 TOPCON Corporation


Table of Contents

Chapter 1 Overview...........................................................................6
Chapter 2 Setup Color Mapping 32 System .....................................7

2.1 Software Requirements ....................................................7


2.2 Installing Color Mapping 32 ..............................................8
2.3 Communication Setting...................................................14
2.4 Preparation for KR-7000P...............................................16
2.5 Preparation for KR-8000P...............................................19

Chapter 3 Getting Started................................................................23

3.1 Starting Color Mapping 32 ..............................................23


3.2 Color Mapping 32 Components ......................................23
3.3 Operating Color Mapping 32...........................................26
3.4 Exiting Color Mapping 32................................................26

Chapter 4 Color Map Report Data...................................................28

4.1 Receiving Color Map Report Data ..................................28


4.2 Display Color Map Report Data ......................................29
4.3 Patient Registration ........................................................29
4.4 Saving Report Data ........................................................31
4.5 Color Map Report Window Control .................................32
4.6 Opening Saved Report Data...........................................33
4.7 Viewing Report Data from the Database ........................34

Chapter 5 Option Settings ...............................................................37

5.1 Map Method....................................................................37


5.2 Scale Unit .......................................................................37
5.3 Map Type........................................................................38
5.4 Overlays .........................................................................38
5.5 Peripheral .......................................................................39
5.6 Others.............................................................................39
5.7 Image View .....................................................................40

Chapter 6 Contact Lens Simulation Report Data.............................42

6.1 Display Contact Lens Simulation Report Data ................42


6.2 Parameters of the Contact Lens Simulation Report........45
6.3 Handling Each Lens Type...............................................45
6.4 Parameter Setting...........................................................46
6.5 Contact Lens Utility.........................................................47

Page 4 TOPCON Corporation


Chapter 7 Printing Reports ..............................................................50

7.1 Print Preview Screen ......................................................50


7.2 Print Setup Dialog Box....................................................51

Chapter 8 Other Features................................................................52

8.1 Hiding Tool Bar and Status Bar ......................................52


8.2 Cascade and Tile............................................................52
8.3 Select COM Port.............................................................52
8.4 Reset COM Port .............................................................52

Software License Terms .......................................................................54

Page 5 TOPCON Corporation


Chapter 1

1.1 Overview

Topcon’s Color Mapping 32 is a 32bit multiple-document report Windows application


running under Microsoft Windows 95/98/NT and Microsoft Windows XP.

Color Mapping 32 works with the tri-function Topcon KR-7000P/ KR-7100P/ KR-
8000PA/ KR-8100PA/ KR-8100P, auto-refractometer, expanded auto-keratometer and
placido disk-based corneal mapping system. The data captured by the KR-7000P/ KR-
7100P/ KR-8000PA/ KR-8100PA/ KR-8100P is transferred to Color Mapping 32 via an
RS-232C interface, and is then reconstructed into corneal topography color map data.
The multiple documents include refractometer data, keratometer data, and a corneal
topography color map. To send refractometer and/or keratometer data to the TOPCON
CV Power Supply Unit, the Color Mapping 32 creates the necessary data for the
TOPCON CV Power Supply Unit and sends it using the second RS-232C port of the PC.

After reconstructing the corneal topography color map data, the multiple document report
may be viewed on the Windows screen or printed on a color printer.

The Color Mapping 32 provides various options for evaluating cornea, such as tangential
/ sagittal map, adjustable / normalized / absolute map, diopter / mm display, overlay
information display, auto-print, contact lens fitting simulation, etc. Default option
parameters may also be set.

An important feature of Color Mapping 32 is that it creates and supports a patient


information database. The database services integrated in the software speeds-up patient
data storage/ retrieval and simplifies data analysis.

If the auto-print option is enabled, Color Mapping 32 prints a multiple-document report


to a color printer automatically using default option parameters when new data is
received from the KR-7000P/ KR-7100P/ KR-8000PA/ KR-8100PA/ KR-8100P.

Page 6 TOPCON Corporation


Chapter 2

Setup Color Mapping 32 System


2.1 System Requirements

2.1.1 Hardware Requirements


The following hardware is necessary to run Color Mapping 32:

· 100% IBM PC compatible computer with i-486DX or better


· Minimum 8MB of system memory
· Minimum 1MB of video memory
· 2MB of free disk space at installation
· A color printer supported by Windows
· An available COM port*
· A KR-7000P/ KR-7100P/ KR-8000PA/ KR-8100PA/ KR-8100P to PC interface
cable**
* To send the refractometer and/or keratometer data to the TOPCON CV Power Supply
Unit, an additional COM port is needed.
** To send the refractometer and/or keratometer data to the TOPCON CV Power Supply
Unit, the PC to CV Power Supply Unit interface cable is needed.

In the above specifications, the video memory and the system memory may be the most
important hardware for Color Mapping 32. For a computer with 1MB of video memory,
the video mode can be set to 1024x768 256 colors and 640x480 16-million colors.

The faster the computer CPU, the better the performance of Color Mapping 32. In
general, performance of Windows is influenced most by the amount of system memory
and the speed of the hard disk. If the system appears to be running slow, try adding
system memory first. If it still seems slow, upgrade the computer with a faster CPU and
much larger hard disk.

Note that the necessary memory capacity and hard disk capacity
may differ for each PC.

2.1.2 Software Requirement


To run Color Mapping 32, the following software is necessary:

· Microsoft Windows 95/98/NT or Microsoft Windows XP.


· The video mode of Windows should be set to at least 640x480 x 256 colors.

Page 7 TOPCON Corporation


2.2 Installing Color Mapping 32

2.2.1 Running Setup Program


If the previous version of Color Mapping 32 was installed, uninstalling is always
recommended. See section 2.2.2 for Uninstalling.
Follow the instructions bellow to install Color Mapping 32 for PC with WINDOWS 95:
Quit any applications that are currently running.
If you use the Microsoft Plus! System Agent, right-click the System Agent icon on the
toolbar, and then click Suspend System Agent.

• Insert the floppy disk into your computer’s drive;

1. Click the [Start] button of task bar and click [Run] menu.

2. The [Run] dialog box is displayed. Enter [A:\Setup.exe], insert the floppy disk #1/1
and click the [OK] button.

Page 8 TOPCON Corporation


3. Once the Color Mapping 32 installation program is started, it displays the following
‘Welcome’ dialog box:

Click the ‘Next’ button to continue the installation

4. In this dialog box, specify the destination where Color Mapping 32 is to be installed.
It is not recommended to change the default destination directory. Click the ‘Next’
button to continue.

Page 9 TOPCON Corporation


5. Specify Disk Name, you will use for the Patient Information Database.

6. Select directory for storage of the color map image files that Patient Database
Records refer to.

Page 10 TOPCON Corporation


7. In this dialog box, click the ‘Finish’ button to finish the installation.

When the Installation is done click on the shortcut icon to start the Color Mapping
32.The shortcut icon must be created by the Installation program on your desktop screen
when the installation is completed(see section 3-1)

2.2.2 Removing The Color Mapping 32


1. Click the [Start] button, point to [Settings], and then click [Control Panel].

Page 11 TOPCON Corporation


2. Double-click [Add/Remove Programs].

Page 12 TOPCON Corporation


3. Click the [Install/Uninstall] tab, click [KRP32], and then click [Add/Remove].

4. The following dialog box will appear in order to make sure you are uninstalling the
Color Mapping 32 program. Click ‘Yes’ button to start the uninstalling.

Page 13 TOPCON Corporation


5. In this dialog box, click the ‘OK’ button to finish the uninstalling.

2.3. Communication Setting

2.3.1. Port Setting


If it is necessary to select the communication port for the KR-7000P/ KR-7100P/ KR-
8000PA/ KR-8100PA/ KR-8100P, choose ‘Select Com Port for KR’ in the [Port] menu to
get the Select COM Port dialog box. (Figure 2-1) To change the COM port number,
select COM# (# is number of communication port) and click the ‘OK’ switch. The
selected communication port will be initialized automatically. If None was selected,
Color Mapping 32 displays only saved data.

Figure 2-1 KR port selection Dialog Box

Page 14 TOPCON Corporation


If it is necessary to select the communication port for the CV Power Supply Unit, choose
‘Select Com Port for CV’ in the [Port] menu to get the Select COM Port dialog box.
(Figure 2-2) To change the COM port number, select COM# and click the “OK” switch.

Figure 2-2 CV port selection Dialog Box

If None was selected, Color Mapping 32 does not send data to the TOPCON CV Power
Supply Unit. Information about the old and new formats can be found in the TOPCON
CV Power Supply Unit documentation.

2.3.2 Communication Format Instrument Setting


Software supports data communication with two types of instruments:
• KR7000P(Include KR7100P)
• KR8000P/19K(Include KR-8100PA/ KR-8100P with 19200Bps)
• KR8000P/38K(Include KR-8100PA/ KR-8100P with 38400Bps)
To receive measurements the type of connected instrument must be selected:
1. Select pull-down Port Menu by clicking on the Port button on the Menu Bar.
2. Set the instrument type by selecting appropriate option KR7000P/KR8000P from the
[Select Instrument] pull-down menu.
Note: The previous setting is indicated with the check mark next to the instrument type
in the [Select Instrument] pull-down menu.

2.3.3 Cable Connection


For a KR-7000P/ KR-7100P/ KR-8000PA/ KR-8100PA/ KR-8100P to PC interface
cable: (A round connector 8-PIN DIN on one end and a 9-PIN D-SUB connector on the
other end.)
To connect the interface cable between the KR-7000P/ KR-7100P/ KR-8000P/ KR-
8100PA/ KR-8100P and the PC:
1. Turn off the power switch of the KR-7000P/ KR-7100P/ KR-8000PA/ KR-8100PA/
KR-8100P and the PC.
2. Align the round cable connector (8-PIN DIN) with the KR-7000P/ KR-7100P/ KR-
8000PA/ KR-8100PA/ KR-8100P’s OUT port of “DATA TERMINAL” and press the
round cable connector into the port.
3. Connect the other connector (9-PIN DSUB) to the PC COM port.

Page 15 TOPCON Corporation


2.4 Preparation for KR-7000P

2.4.1 Setting Up KR-7000P


Make sure the following settings of the KR-7000P/ KR-7100P are correctly configured:

RS232C FORM EXT


BAUD-RATE 9600

To change settings of the KR-7000P/ KR-7100P:


1. Turn on the power switch of the KR-7000P/ KR-7100P while pressing the
“CONTACT / GLASSES” switch. The initial setting screen appears on the screen.
2. Release the “CONTACT / GLASSES” switch
3. “INITIAL SETTING” screen appears on the screen (Figure 2-3).

INITIAL SET
NUMBER SET
PRINT OUT
ONLINE
PLACIDO SET

Figure 2-3 Initial Setting Screen

4. Bring the cursor to “ONLINE” by pressing the measuring switch.


5. Press the PRINT switch. The on-line screen appears on the screen.

CL INPUT NO
RS-232C FORM EXT
BAUD-RATE 9600
RS232C OUT TYPE REF
RS232C KRT CENT

Figure 2-4 Online Setting Screen

6. Bring the cursor to “RS-232C FORM” by pressing the measuring switch.


7. Bring the cursor to “RS-232C FORM” to “EXT” by pressing the PRINT switch. The
“BAUD-RATE will be set to 9600 automatically. Also change the “RS232C OUT
TYPE” to “ALL” and the “RS232C KRT” to “BOTH”.
8. Bring the cursor to “NEXT by pressing the measuring switch.
9. Press the PRINT switch.
10. Bring the cursor to “END” by pressing the measuring switch.
11. Press the PRINT switch. “END OK?” appears on the screen.
12. Press the PRINT switch. “SETTING MENU DATA” will be printed out, and the
measurement screen will appear.

Page 16 TOPCON Corporation


SETTING MENU DATA

VD 12.00
STEP 0.25
…………………………………
………… ……
RS232C FORM EXT
BAUD-RATE 9600
…… ……
…… ……
LIGHTING RING

Figure 2-5 Printout Setting Data

13. Please make sure settings of the KR-7000P/ KR-7100P are correctly configured:

2.4.2 Calibration Data Registration


Before transferring the calibration data of the KR-7000P/ KR-7100P to the PC, proceed
with following steps:
3.2 Start the Color Mapping 32 program. When starting the software, the message,
“Calibration Data does not exist. Please setup Calibration data” may appear until the
calibration data has been transferred from the KR-7000P/ KR-7100P (Figure 2-6).

Figure 2-6 No calibration data message box

Please click the ‘OK’ button to prepare to receive data from the KR-7000P/ KR-
7100P.
3.2 Set the instrument's type by clicking on following controls from the main menu
bar:
• Select [Port]-[Select Instrument] from Menu Bar.
• Select KR7000P from [Select Instrument].

If the KR-7000P/ KR-7100P unit is replaced, it is necessary to transfer the new unit’s
calibration data to the Color Mapping 32 in order to update the registered calibration data.
In this case, the message in Figure 2-6 may not appear, because the old calibration data is
already registered.

Page 17 TOPCON Corporation


2.4.3 Calibration Data Transfer Procedure
The following steps are required for the KR-7000P/ KR-7100P to transfer the calibration
data:
1. Dip switch 7 & 8 at position ON and 1 through 6 at position OFF. Rotary switch to
position 7.

Figure 2-7 Switches Condition (Calibration Data Registration)

2. Turn on the KR-7000P/ KR-7100P, (a “PLACIDO CHECK” message will appear).


3. Press the joystick once to enter the submenu.
4. Press the PRINT switch and move the cursor to “5:CALIB DATA OUT”.
5. Press the joystick. The KR-7000P/ KR-7100P will send the calibration data to the
PC.
6. Turn off the KR-7000P/ KR-7100P.

2.4.4 KR-7000P Measurement mode Setting


In order to transfer measurement data to the PC, please make sure Dip switches are in the
following positions:

Dip switch 7 position OFF


Dip switch 8 position ON
Rotary switch position ‘0’

Page 18 TOPCON Corporation


Figure 2-8 Switches Condition (Measurement Mode)

Turn on the KR-7000P/ KR-7100P.

After measuring the patient’s eyes, press the GRAPHIC PRINT SWITCH on the KR-
7000P/ KR-7100P to transfer the necessary data to the PC.

Memo:
1. If “MAPPING PRT” on the KR-7000P/ KR-7100P is set for PRINT, you may also
use the PRINT switch to send data.
2. If a printout from the KR-7000P/ KR-7100P is not necessary, lift the paper retainer
lever.
3. Usually, registering calibration data needs to be done only once. However, when the
KR-7000P/ KR-7100P unit is replaced or returned from repair, it is necessary to
transfer the new calibration data to the Color Mapping 32 in order to update the
registered calibration data.
4. When a KR-7000P/ KR-7100P keeps displaying the “WAITING DIPSW8” message
for a long time, please make sure the Dip switch 8 is ON.
5. When a KR-7000P/ KR-7100P keeps displaying the “CALIBRATING” message for
a long time, please check the interface cable connection.
6. When a Color Mapping 32 displays error messages such as “CEbreak”, “CEerror”,
etc, please check the KR-7000P/ KR-7100P settings are “RS232C FORM EXT”,
“BAUD RATE 9600”.

2.5 Preparation for KR-8000P

2.5.1 Setting up KR-8000P


The following setting procedure is applicable for the KR-8000PA/ KR-8100PA/ KR-
8100P types of the instruments.
While pressing MENU SWITCH on the control panel of the KR-8000PA/ KR-8100PA/
KR-8100P, turn on the KR-8000PA, "INITIAL MENU” screen appears.

Page 19 TOPCON Corporation


1. Select “ON-LINE" option from the “INITIAL MENU” screen to bring up the “ON-
LINE” screen.

Figure 2-9 “ON-LINE” Screen

2. Press the joystick and bring the cursor to “RS232C FORM”.


3. Press the PRINT switch to highlight EXT (available for later version of Color
Mapping 32 Version 1.24).
4. Press the joystick and bring the cursor to “BAUD-RATE”.
5. Press the PRINT switch and highlight 38400 or 19200. (For saving transfer time,
select 38400Bps).
6. Press the PRINT switch and bring the cursor to “EXIT”.
7. Press the PRINT switch to exit "ON-LINE" screen.

2.5.2 Calibration Data Registration


Before transferring the calibration data of the KR-8000PA/ KR-8100PA/ KR-8100P to
the PC, proceed with following steps:
1. Start the Color Mapping 32 program. When starting the software, the message,
“Calibration data does not exist. Please setup Calibration data” may appear until the
calibration data has been transferred from the KR-8000PA/ KR-8100PA/ KR-8100P
(Figure 2-6). Please click the “OK” button to prepare to receive data from the KR-
8000PA/ KR-8100PA/ KR-8100P.
2. Set the instrument's type by clicking on following controls from the main menu bar:
• Select [Port]-[Select Instrument] from Menu Bar.
• Select KR8000P/38K or /19K from [Select Instrument].
Selection must correspond to the instrument’s “BAUD-RATE” setting, please refer to
the Section 2.5.1 (Step 4)

If the KR-8000PA/ KR-8100PA/ KR-8100P unit is replaced, it is necessary to transfer


the new unit’s calibration data to the Color Mapping 32 in order to update the registered
calibration data.
2.5.3 KR-8000P Setting and Calibration Data Transfer
The following setting procedure is applicable for the KR-8000PA/ KR-8100PA/ KR-
8100P types of the instruments.
1. Turn on KR-8000PA/ 8100PA/ 8100P "PLACIDO SET" screen from "INITIAL
MENU".

Page 20 TOPCON Corporation


Figure 2-10 PLACIDO SET Screen

2. Press the joystick and bring the cursor to “PC S/W SETUP”.
3. Press the PRINT switch. Calibration data is transferred automatically and setup of
Color Mapping 32 is done.
4. Press the joystick and bring the cursor to “EXIT”.
5. Press the PRINT switch. “EXIT OK?” appears on the screen. Press the PRINT
switch. “SETTING MENU DATA” will be printed out, and the measurement
screen will appear
SETTING MENU DATA

VD 12.00
STEP 0.25
…………………………………
………… ……
RS232C FORM EXT2
BAUD-RATE 38400
…… ……
…… ……
LIGHTING RING

TOPCON
Figure 2-11 SETTING MENU DATA Screen

6. Please make sure settings of the KR-8000PA are correctly configured.

2.5.4 KR-8000P Measurement Mode Setting


The following setting procedure is applicable for the KR-8000PA/ KR-8100PA/ KR-
8100P types of the instruments.

In order to transfer measurement data to the PC, configure the instrument RS232C output
port by performing the following steps:
1. Press “MENU SWITCH” of the control panel on measurement mode.
"SETTING MENU" screen appears.
2. Press the joystick and bring the cursor to “RS232C”.
3. Press the PRINT switch to highlight “YES”.

Page 21 TOPCON Corporation


Figure 2-12 SETTING MENU Screen

Press the joystick and bring the cursor to “EXIT”. Press the PRINT switch to exit
"SETTING MENU" screen

After measuring the patient’s eyes, press the GRAPHIC PRINT SWITCH on the control
panel of KR-8000PA/ KR-8100PA/ KR-8100P to transfer the necessary data to the PC.

Memo:
1. If “MAPPING PRT” on the KR-8000PA/ KR-8100PA/ KR-8100P is set to
“PRINT”, you may also use the PRINT switch to send data.
2. If a printout from the KR-8000PA/ KR-8100PA/ KR-8100P is not necessary, lift the
paper retainer lever.
3.2 Usually, registering calibration data needs to be done only once. However, when
the KR-8000PA/ KR-8100PA/ KR-8100P unit is replaced or returned from repair, it
is necessary to transfer the new calibration data to the Color Mapping 32 in order to
update the registered calibration data.
3.2 If no data is transferred from a KR-8000PA/ KR-8100PA/ KR-8100P, Please
check the setting of port. “RS232C” is “YES” and “RS232C FORM EXT”, “BAUD
RATE 19200 or 38400”.
3.2 When a KR-8000PA/ KR-8100PA/ KR-8100P keeps displaying the “CABLE
UNCONNECTED” message, please check the interface cable connection and port
setting.

Page 22 TOPCON Corporation


Chapter 3

Getting Started

3.1 Starting Color Mapping 32


To start Color Mapping 32 click on the shortcut icon labeled KRP32
(Figure 3-1) in your Desktop Window.

KRP32
Figure 3-1 Shortcut Icon

3.2 Color Mapping 32 Components


Color Mapping 32 Window

The Color Mapping 32 window consists of several elements such as the Title Bar, the
Menu Bar, the Toolbar and the Status Bar. The Title Bar is located at the top of the
window. The Menu Bar is just below the Title Bar, and the Toolbar below that. The
Status Bar is located at the bottom of the window.

Figure 3-2 Color Mapping 32 Window

Page 23 TOPCON Corporation


Color maps are displayed in windows referred to here as “Report Windows”. A report
window is created when a Color Map file is opened and is removed when the file is
closed. The Color Mapping 32 window is maximally sized on start up to make room for
report windows to be as large as possible. It is possible to make the window smaller,
however, the report windows can never be larger than the Color Mapping 32 window.

Title Bar The title bar is used to show the report currently displayed.

Menu Bar The menu bar consists of several items. By clicking these items,
the pull-down menu related to the item will be opened. By
choosing an item in a pull-down menu, you can call the function
assigned to the item.

[File] Open...
Close*
Close All*
Save*
Save As*
Open from Database
Save to Database*
Print...*
Print Preview*
Print Setup...
Exit
[Patient] Select Patient
Register Patient
Deleted Patient
* Item in the [Patient] menu is enabled only if the
Patient Registration Database is not empty
[View] Toolbar
Status Bar

[Port] Select Com Port for KR


Select Com Port for CV
Reset Port
Select Instrument***
KR7000P
KR8000P/19K
KR8000P/38K

[Utility] Map Options*


Call Map*
Color Map*
Contact Lens Fitting [OD(Right)]*
Contact Lens Fitting [OS(Left)]*
Contact Lens Utility
Delete Data from Database
Date Format Settings
Change Parameters**
Page 24 TOPCON Corporation
Pan & Tilt**
Profile Graph**
Isometric Graph**
[Window]* Cascade
Tile
[Help] About Color Mapping 32...

Note:
* Items in the Menu Bar or in the each pull-down menu are available only,
when the Color Map Report is displayed.
** Items in the Menu Bar or in the each pull-down menu are available only,
when the Contact Lens Fitting Report is displayed.
*** Items in the Menu Bar or in the pull-down menu are available only, when
there is no document (report) in the main frame window.

Tool Bar The tool bar provides quick access to items in pull-down menus of
the menu bar. By clicking an icon on the tool bar, the function
assigned to the icon is directly called.

Open Icon Open [File]

Save Icon Save [File]

Save to DB Save to the Database [Utility]

Open from DB Retrieve from the Database [Utility]

Map Options Map Options Settings * [Utility]

Color Map/Contact Lens Color /Simulation Maps* [Utility]

Pan & Tilt Icon Contact Lens Fitting** [Utility]

Printer Icon Print [File]

Info Icon About Color Mapping 32 [Help]

Note:

Page 25 TOPCON Corporation


* Items in the Menu Bar or in the each pull-down menu are available only,
when the Color Map Report is displayed.
** Items in the Menu Bar or in the each pull-down menu are available only,
when the Contact Lens Fitting Report is displayed.

Status Bar The status bar shows the status of Color Mapping 32.

Report Window When a report is displayed on the screen, a new window for the
report is created in the Color Mapping 32 window. Although two
or more report windows may be open simultaneously, only one
may be active. Most functions work on the report in the active
report window. Each report window has the title on the top to
show identification information of the report.

3.3 Operating Color Mapping 32


Once Color Mapping 32 is started, the communication port will be initialized
automatically and ready to receive transfer data from the KR-7000P/ KR-7100P/KR-
8000PA/ KR-8100PA/ KR-8100P. When the data is received, the corneal topography
mapping data is reconstructed, and a new report window is created automatically. Use
the menu icons on the tool bar as a short cut for some menu items. A menu item or a
menu icon displayed in gray means that the item or the icon is not available at that time.
If the port for the TOPCON CV Power Supply Unit has been set, the Color Mapping 32
creates the necessary data using the specified data format and sends it to the TOPCON
CV Power Supply Unit.

To display reports, choose [Open] from the [File] menu. Color Mapping 32 will display
a dialog box to get necessary information. Type or select items in the dialog box, then
click “OK” to continue. To apply any options to the displayed report, choose [Option
Setting] from the [Utility] menu. The Color Mapping 32 will display the option setting
dialog box to change option parameters. Change parameters in the dialog box, then click
“OK” to continue. The changed parameters will be immediately applied to the report.
To get contact lens simulation report window, choose “Contact Lens Fitting” from the
[Utility] menu. The Color Mapping 32 will display the Contact Lens Parameter setting
dialog box to set for perform the contact lens fitting simulation.

To print a report, choose [Print] from the [File] menu. Color Mapping 32 will send the
report information to the printer. If the “Auto Print” check box in the option setting
dialog box has been checked, the color map report information will be sent automatically
as soon as the program reconstructs the new report using the data transferred from the
KR-7000P/ KR-7100P/KR-8000PA/ KR-8100PA/ KR-8100P.

3.4 Exiting Color Mapping 32


To exit Color Mapping 32, choose [Exit] from the [File] menu. Upon exit, the program
closes all report windows and releases resources. Before exiting, save any important new

Page 26 TOPCON Corporation


reports that were created during the session, or they will be lost. The program does not
prompt to save new reports when exiting.

Page 27 TOPCON Corporation


Chapter 4
Color Map Report Data
4.1 Receiving Color Map Report Data
To receive measured data from the KR-7000P/ KR-7100P/ KR-8000PA/ KR-8100PA/
KR-8100P, press the GRAPHIC PRINT SWITCH (open the cover/door of the control panel
to use this switch) on the instrument. After receiving data, Color Mapping 32
reconstructs the corneal structure data.

4.1.1 KR- 8000P Data Transfer Setting


To transfer measurement data from the KR-8000PA/KR-81000PA/KR-8100P proceed
with flowing steps.
1. Press the GRAPHIC PRINT SWITCH , “IMAGE DATAOUT MENU” screen will
appear (Figure 4-1).
2. Press the joystick to highlight one of the menu items (Figure 4-1).
Each item indicates type of transferring image that will be sent to the Color Mapping
32 with numeric data.

Figure 4-1 Image Data Out Screen

Each menu item corresponds to the type of image that will be attached to the numeric
data package transferring to the Color Mapping 32, as specify below:
• NO IMAGE data transfer without image
• BOTH data transfer with the images for Left and Right eyes
• RIGHT data transfer with the Right eye’s image only
• LEFT data transfer with the Left eye’s image only
3. Press GRAPHIC PRINT SWITCH to conform that the menu items’ selection is
completed. Instrument must display “RS232 DATA OUT” message.
Each item indicates type of transferring image that will be sent to the Color Mapping
32 with numeric data.

Page 28 TOPCON Corporation


4.2 Display Color Map Report Data
Using the transferred report data, Color Mapping 32 creates a new color map report
window. This report window consists of < Ref Data >, < Kerato Data >, < Peripheral
Data >, and the color map reports.

Figure 4-2 Color map report display

4.3 Patient Registration


The patient registration service allows the user to create a database of records with
patient information on an available storage media.
‰ There are two alternatives to access the Patient Registration dialog box:
• By selecting the [Patient] item from the Menu Bar;
• By selecting [Save to Database] from the [File] pull-down menu (see Section 4.4)

‰ To register a patient using the Menu Bar:


Page 29 TOPCON Corporation
• Select the [Patient] item from the Menu Bar;
• Select [Register Patient] item from [Patient] menu (Figure 4-3).
• Fill in the dialog box form, click on “Register” button to create patient record in
the Database;

Figure 4-3 Register Patient Dialog Box

‰ To retrieve and update patient information from the Database:


• Select [Patient] item in the Menu Bar;
• Click on the [Select Patient] item from [Patient] menu. (Figure 4-4);

Figure 4-4 Select Patient Dialog Box

• Enter a search key in ID. Code and/or Last Name lines of the dialog box:
• Click the “Information” button to retrieve a patient record in the Patient
Information dialog box. To store modified record, click the “Update” button.
• Click the “OK” button to retrieve a color map report image associated with
the entered search key;

‰ To delete record with patient information from the Database:


Page 30 TOPCON Corporation
• Select [Patient] item in the Menu Bar.
• Select [Delete Patient] item from [Patient] menu.
• Select a record from the list and press the “Delete” button on the dialog box;

Figure 4-5 Delete Patient Dialog Box

4.4 Saving Report Data


‰ Color Mapping 32 support two types of report data storage:
• Saving report data as a regular file with extension *.krp/*.kp8 for data received
from KR-7000P/ KR-7100P/ KR-8000PA/ KR-8100PA/ KR-8100P instrument on
any available storage media.
• Saving report data as a database file in database disk area allocated on available
archive media. Patient information registration records and associated Color
Mapping 32 reports are stored in the created archive.

‰ To save a document as a regular file from the Color Mapping 32 Report Window:
• Select the [File] item in the Menu Bar.
• Select the [Save As] item. (Do not change extension ‘.krp or .kp8’)

Figure 4-6 Save Report Dialog Box

When saving the report data as a file, Color Mapping 32 attaches the calibration data to
the file. This means that even if the KR-7000P/ KR-7100P/ KR-8000PA/ KR-8100PA/

Page 31 TOPCON Corporation


KR-8100P unit is replaced, the saved report data file may still be used in the new
configuration.

‰ To save a document to the database file from the Color Mapping 32 Report Window:
• Select the [File] item in the Menu Bar.
• Select [Save to Database] (see Section 3.2).
• Fill patient registration form in the dialog box.
• Click “OK” (Figure 4-7).
• Fill dialog box form and click “OK” to save the report.

Figure 4-7 Save Data Dialog Box

4.5 Color Map Report Window Control

Closing Color Map Report Window


To close a report window, make the window active, then choose [Close] from the [File]
menu or use the system menu of the report window. Alternatively, access the system
menu of the window by clicking the square at the upper left corner, the left end of the
title of the window.

Putting Color Map Report Window on Top


Many report windows can be opened simultaneously. The number of report windows
one can open is only limited by the amount of system memory. The report window
opened last is displayed on top. To place a different report window on top, click
anywhere on that report window using the left mouse button.

‰ To enable this service:


Page 32 TOPCON Corporation
• Click on [Open] from DB icon in the Tool Bar to display the Select Data dialog
box.
• Select data (see Section 4.6) to bring up a color map report data from the database.
• Select a measurement point by moving the mouse on the image map and clicking
the left button. Measurements associated with position of cross-hair marker on the
color image will be displayed at the left top corner of the Color Map Report
Window.

4.6 Opening Saved Report Data


To open a saved report data file, choose [Open] from the [File] menu, or click the open
icon on the tool bar. The following dialog box will be displayed to select the saved
report file:

Figure 4-8 Open Report Dialog Box

After choosing a report file and clicking “OK”, the dialog box will be hidden, and the
selected report will be displayed in a new report window.

The above dialog box can be displayed anytime by choosing [Open] in the [File] menu or
by clicking the open file icon on the tool bar.

Page 33 TOPCON Corporation


4.7 Viewing Report Data from the Database
‰ Report data saved on the database disk as archive can be retrieved in the following
formats:
• “Single map” is a view of one image with associated measurements and patient
data (Figure 4-9). Selection of more then one file from the Record List Box
(Figure 4-8) list disables the “OK” button of the Select Data dialog box.
• “Multi map” image is a side by side view of several images with associated
measurements and patient data (Figure 4-9). Patient records may be selected for
the same eye as well as for different eyes from the database Record List Box.
Selection of more records then the map can display disables the “OK” button of
the Select Data dialog box (Figure 4-9);
• “Difference Map” view is a color presentation of the difference between two
images retrieved from database with associated measurement difference display
box (Figure 4-10). The compared images are also presented side by side on the
map. Selecting records of different eyes from the Select Data dialog box disables
the “OK” button.

‰ To retrieve Color Mapping 32 report image from the Database:


• Select the [Open] from DB icon from the Tool Bar or click [Open] from Database
on the [File] pull-down menu (see Section 3.2). The [Select Data] dialog box
(Figure 4-9) will be displayed on the screen
• Use the scroll list or press the [Select Patient] button to enter a search key;
• Click the “OK” button to retrieve the Color Mapping 32 report from the database

Figure 4-9 Select Data Dialog Box

Page 34 TOPCON Corporation


Multi Map View
Map view displays running measurements associated with the position of the cursor on
the selected color map image. Measurement display in the bottom right corner of each
image box (Figure 4-10) contains of following information:
PWR Power in diopters at the cursor position;
RAD Radius of curvature at the cursor position
DIST Distance of cursor from the center of the grid in mm
AXIS Angle of the axis connecting the cursor with the center of the grid
in degrees (0°-360°);
DISTP* Distance of cursor from the center of the pupil in mm
AXISP* Angle of the axis connecting the cursor with the center of the pupil
in degree (0°-360°)

‰ To enable Multi Map View:


• Click the [Open] from DB icon in the Tool Bar to bring up “Select Data” dialog
box;
• Select one of the “Multi Map” options from the “Select Map” box of the
“Select Data” dialog box to bring up a “Multi Map” report data from the
database;
• Select measurement point by moving the mouse on the image map and clicking
the left button. Measurements associated with the position of cross-hair marker on
the color image will be displayed

Figure 4-10 Multi Images Map View

Page 35 TOPCON Corporation


Difference Map View

Map view displays running measurements associated with position of the cursor on the
selected color map image. Measurement display is in the bottom, right corner of each
comparing image box (Figure 4-10). It contains the same information type that the
images on the Multi Map View along with the difference between the two. The following
measurement information is provided for each map:
PWR Power measurements of each map and the difference of the two.
RAD Radius of curvature for each map and the difference of the two (mm).
DIST Distance from the center of the grid for each map in mm.
The difference map reports the distance of the first image in mm.
AXIS The angle between the line connecting the cursor with the center of the
grid and X-axis of the greed in degrees (0°-360°). The difference map
reports the angle value of the first image.
DISTP* Distance from the center of the pupil for each map in mm.
AXISP* The angle between the line connecting the cursor with the center of the
pupil and X-axis of the greed in degrees (0°-360°). The difference map
reports the angle value of the first image.
* Measurement is displayed if pupil detection data is available
in the image file.
To enable “Difference Map” View follow the steps from the paragraph “Multiple Map
View” for “Difference Map” selection in the “Select Map” box of “Select Data” dialog
box. (Figure 4-9).

Figure 4-11 Difference Image View

Page 36 TOPCON Corporation


Chapter 5
Option Settings
When a color map report is open, the options may be changed for that report. To get the
option dialog box menu, choose [Map Options] from the [Utility] menu, or click the
option icon on the tool bar. The following dialog box will be displayed to change
options:

Figure 5-1 Option Setting Dialog Box

5.1 Map Method


Sagittal: This power is based on the normal distance from the cornea to the
refractive axis (also known as Axial Power).

Tangential: This power is based on the surface radius for each data point (also known
as Instantaneous Power).

5.2 Scale Unit


Diopter: Displayed color map based on Diopter power scale.
Page 37 TOPCON Corporation
mm: Displayed color map based on mm power scale.

5.3 Map Type


Adjustable: Use the color map center and step values to adjust the color levels. By
using appropriate values, more detail can be seen in the map. (The center
value will appear as the bottom of the eleventh color.)

Normalized: Minimum and Maximum levels of the data are used for limits of the color
map. Thus, data will stretch over entire map. In cases of extreme data
range, the top 1% and bottom 1% are excluded.

Absolute: Standard scale ranging from 35.5D to 52D with a step size of 1/2D, or
6.0mm to 9.3mm with a step size of 0.1mm. 33 different levels are used
for this map by 22 colors.

5.4 Overlays
Cross Scale: X and Y axes overlay

Angle Scale: Displays angle measurement around the color maps.

mm Grid Scale: Overlay of a 1 mm grid

Kerato Axis:

None: No Kerato Axis displayed.

Kerato Axis: Kerato Axis displayed based on the Keratometer axis.

Sim-K Axis: Shows the keratometric circle (radius 1.5mm) along with the
strongest axis ( as a black line ) and weakest axis ( as a gray line ).

Pupil: Displays pupil boundary curve. Pupil check box is enabled, if pupil edge
detection points are available in the opened map document file (Figure 5-2)
This option Is available for KR-8000PA/ KR-8100PA/ KR-8100P

Page 38 TOPCON Corporation


Figure 5-2 Color map with pupil overlays

5.5 Peripheral
When measuring a patient eye with 5 point peripheral measurement, this switch becomes
available along with peripheral display options:

Figure 5-3 Peripheral Point 5 Option Dialog Box

Display Point 5 Map: If this box is checked, the peripheral data will be displayed as a 15
degree step map. If this box is unchecked, the peripheral data will be displayed as
numeric data.

Eccentricity Options

No E Value: No eccentricity data displayed.

Meridian E Value: Meridian eccentricity data displayed. (2 directions)

Semi meridian E Value: Semi-meridian eccentricity data displayed. (4 directions)

5.6 Others
Page 39 TOPCON Corporation
Initial Display Top: If this box is checked, the top of the new report window will be
displayed. If this box is not checked, the bottom ( Color Map ) of
the new report window will be displayed.
Save Settings: If this box is checked, and the ‘OK’ switch is clicked, Color
Mapping 32 saves and uses these settings as the defaults for new
reports.
Auto Print: If this box is checked, data will automatically be sent to the printer
(using default option settings) as soon as the Color Mapping 32
receives and reconstructs the color map structure.

5.7 Image View


This option Is available for KR-8000PA/ KR-8100PA/ KR-8100P

Map: If this button is active color map with pupil center marker will be
displayed, every time user opens map document file. Pupil center marker
will appear only for document files containing pupil detection points.
Image: If this button is active eyes’ color map reports will be replaced with its
images in the color map report window (Figure 5-4). If image is available
only for one eye in the opened document, Color Mapping 32 will display
image only for this eye and color map for the eye without image.
Overlay: This button repeats the same logic as the “Image” button. The difference is
that image is overlaid with color map for each eye which image data is
available.
Side by Side: The button is enabled only for the document, which was opened from the
Color Mapping 32 Database and its display format to “Single Map”
(Section 4.7). Also, eye image data must be available in the database
document.

Page 40 TOPCON Corporation


Figure 5-4 Report window (Image view – Image)

Page 41 TOPCON Corporation


Chapter 6
Contact Lens Simulation Report Data
6.1 Display Contact Lens Simulation Report Data
To get a Contact Lens Simulation Report data when a Color map Report window is
activated, perform following steps:
• Choose “Contact Lens Fitting” from the [Utility] “Call Map” menu, or click the
[Contact Lens] Icon on the Tool bar. When the Contact Lens Icon was clicked and a
Color map Report has data for both eyes, the following “Select Processing Eye”
dialog box will be displayed.

Figure 6-1 Select processing Eye Dialog Box

The contact lens simulation Parameter Setting dialog box will appear (Figure 6-4).

• Select simulation parameters and simulation report view from the Parameter Setting
dialog box, as specify in Section 6.4 later in this chapter.
• Click “OK” to display the contact lens simulation report. The image view type in the
Fitting Color Map box of the report is defined by the settings of the Image View
control buttons in the “Parameter Setting” dialog box (Section 6.4).
• The contact lens simulation report window will display Fitting Color Map view
(Figure 6-2).

Page 42 TOPCON Corporation


Figure 6-2 Contact Lens Fitting Map display with pupil overlay

6.1.1 Contact Lens Simulation Precaution


Contact Lens Simulation
Physician can not use report data for lens prescription without
their personal validation.

Page 43 TOPCON Corporation


Figure 6-3 Contact Lens Fitting Map with pupil and eye image overlay display

Page 44 TOPCON Corporation


6.2 Parameters of the Contact Lens Simulation Report

Abbreviations for the Contact Lens simulation report:


BC Base curve (mm)
BC2 Base curve 2 for toric lens (mm)BC must be greater then BC2
E1 Eccentricity of aspheric lens
TD Total diameter of a lens (mm)
OZ Optic zone (mm) (which affects the optical function of a lens)
SC Secondary curve (mm)
SCW Secondary curve width (mm)
E2 Eccentricity for secondary curve
PC Peripheral curve (mm)
PCW Peripheral curve width (mm)
PC2 Peripheral curve 2 for toric lens (mm) PC must be greater than PC2
AEL Axial edge lift (mm)
VD Vertex distance of spectacles (mm)
PWR Power of the contact lens to correct refraction spherical data (mm)
PanH amount of horizontal lens lag from the corneal (mm)
PanV amount of vertical lens lag from the corneal center (mm)
TilH Horizontal lens tilt angle (mm)
TilV Vertical tilt angle (mm)

For a three curve contact lens, BC, TD, OZ, SC, SCW, PC, and PCW are necessary. If
for a two-curve lens, SC and SCW, or PC and PCW may be omitted. Either SC or PC can
be ignored if their width field (SCW or PCW) is zero.

6.3 Handling Each Lens Type


Lens types can be set in the parameter setting dialog box.
RGP For a RGP lenses, a total of three curves including a base curve ( BC ), a
secondary curve ( SC ), and a peripheral curve ( PC ), are available.
Alternatives ( i.e. BC+SC only, or BC+PC only ) are also available.

TORIC When a TORIC lens type has been selected, the BC2 and PC2 data fields
will be activated. There are basic curve 2 and peripheral curve2,
respectively. Listed below are two available lens structures in the TORIC
lens type.
BC (toric) + SC (spheric) + PC (spheric)
BC (toric) + PC (toric)

If the PC value is same as the PC2 value, the contact lens simulation
function assumes the lens has spherical peripheral curves. In this case, the
SC, and SCW fields will be activated. However, if PC differs from PC2,
since this is a toric peripheral, the SC and SCW fields become disabled.

ASPHERIC When an ASPHERIC lens type has been selected, the E1 and E2 fields
will be activated. The meanings of these fields are eccentricity 1 and 2
Page 45 TOPCON Corporation
respectively. These values are calculated from the corneal topography,
and initially, the two values are the same. One or both of them may be
changed according to the manufacture’s lens specification. For a spherical
secondary curve, set E2 equal to 0 to make it represent a spherical
secondary curve. Use the two lens structure as follows:
BC (aspheric) + SC (aspheric) + PC (spheric)
BC (aspheric) + SC (spheric) + PC (spheric)
In both cases, PC can be omitted when PCW is zero.

SOFT Most SOFT lenses have one BC and One PC, so secondary curve fields
are disabled. The fluorescein simulation is not available for soft lenses.

PMMA For a PMMA lens type, the software treats the lens structure in the same
way as a RGP lens.

6.4 Parameter Setting


When a contact lens simulation report is open or the ‘Contact Lens Fitting’ function from
a color map report has been called for the first time, the parameters may be changed for
that report. To get the parameter setting dialog box menu, choose ‘Change Parameters’
from the [Utility] menu, or click the parameter icon on the tool bar. The following dialog
box will be displayed to change parameters. (‘Select Data Set’ item will be appeared only
when some contact lens data were registered – See Section 6.5 ):

Figure 6-4 Parameter Setting dialog box

Lens Type
Please refer to section “6.3 Handling each lens type”.

Page 46 TOPCON Corporation


Map Type
Absolute map type connects tear layer thickness to an actual fluorescent color.
Normalized map type assigns colors to express the entire thickness range.

Overlays
The functions of the Overlay group of controls are the same as functions of the Overlay
control group in the Map Option Settings dialog box for the Color Map Report document
type, refer to the Section 5.4 of the manual.

Reference BC
Parameter helps to find a base curve that meets a certain apical clearance demand. The
software finds the radius of curvature of a sphere, which is defined by three points.
These points are the center of the lens with a certain apical clearance, and two optic zone
end points, which touch the cornea.

Sagittal Vault
If the sagittal vault value is supposed to be a certain value, input that value. An
appropriate TD value will be calculated for this sagittal vault.

Axial Edge Lift


The required AEL (Axial Edge Lift) value is specified, the software finds the appropriate
PC value.

Graph Setting: Profile Graph


The tear layer thickness profile graph is displayed at the specified angle value.

Graph Setting: Isometric Graph


The circular tear layer variation graph is displayed at the specified radius value.

Select Data Set


The pull down scroll list appears when more then one contact lens data sets have been
registered. The software will set the parameters based on the selected contact lens data
set.

Image View
This option Is available for KR-8000PA/ KR-8100PA/ KR-8100P
The functions of the Image View control group are the same as the functions of its
counterpart in the Map Option Settings dialog box of the Color Map Report document
type, refer to the Section 5.7 of the manual. There are three alternative views including
the default Fitting Color Map view available and may be selected by setting the Image
View control group in on of the following options:
• MAP option to display Fitting Color Map(Figure 6-2)
• IMAGE option to display eye image the same as in the Color Map Report, refer to
Section 5.7(Figure 5-4)
• OVERLAY option to display Fitting Color Map overlaid with eye image (Figure 6-3)

6.5 Contact Lens Utility

Page 47 TOPCON Corporation


To get the contact lens utility dialog box menu, choose ‘Contact Lens Utility’ from the
[Utility] menu. The following dialog box will be displayed to set the default and register
the contact lens parameters sets. The number of the registered contact lens sets is up to 10.
Figure 6-5 Contact Lens Utility dialog box

Available setting parameters for the default and register contact lens sets are shown
below.

Contact Lens Parameters Default Setting


When you have a commonly used contact lens specification, you may define these
parameters. Definable parameters are “Lens Type”, “Map Type”, “Total Diameter of the
contact lens”, “Optical Zone of the contact lens”, “Vertex Distance”, and “Overlays for
the simulation report”. If you have registered some manufacture’s contact lens data sets,
a “Select Data Set” pull-down list will appear.
Figure 6-6 Contact Lens Parameters Default Setting dialog box

CL Advice Enable
This option Is available for KR-8000PA/ KR-8100PA/ KR-8100P
A check box is located in the ‘Contact Lens Parameters Default Setting’ dialog box
(Figure 6-6).
This check box enables automatic setting of the simulation parameters for selected lens
type (Section6.2) to the values calculated by the instrument. These values are displayed
in the ‘<CL Advice>’ section of the Color Map Report, please refer to the Section
4.2(Figure 4-2). CL Advice data is available only for RGP and ASPHERIC type of lens.
The other lens type selections are disabled as long as the check box is checked.

Contact Lens Data Register


It is possible to register some contact lens model parameters sets using the ‘Contact Lens
Data Register function. You may register up to 10 contact lens model parameter sets.
Page 48 TOPCON Corporation
Figure 6-7 Contact Lens Data Register dialog box

Page 49 TOPCON Corporation


Chapter 7
Printing Reports
Color Mapping 32 allows printing of reports displayed on the screen using a Windows
printer. There are 3 menu items related to the print operation in the [File] menu.

• Print... Make a print of the active report window.


• Print preview Preview print on the screen.
• Print setup... Set up the Windows printer.

7.1 Print Preview Screen

To check how the report will be printed before making a print, choose [Print Preview]
from the [File] menu.

Figure 7-1 Print Preview Screen

Page 50 TOPCON Corporation


7.2 Print Setup Dialog Box
The ‘Print Setup’ dialog box is used for changing the printer or paper to be used.

Figure 7-2 Print Setup Dialog Box

Page 51 TOPCON Corporation


Chapter 8
Other Features
8.1 Hiding Tool Bar and Status Bar
It is possible to hide the tool bar and status bar to make more space in the Color Mapping
32 window. To hide the tool bar, choose “Toolbar” in the [View] menu. The check mark
in front of “Toolbar” in the pull-down menu will be erased, and the tool bar will
disappear. To hide the status bar, choose “Status Bar” in the [View] menu. The check
mark at the head of “Status Bar” in the pull-down menu will be erased, and the status bar
will disappear. To display these bars again, choose the same menu item, “Toolbar” or
“Status Bar” in the [View] menu again. These menu items work as a toggle to hide and
show the bars.

8.2 Cascade and Tile


Arrange report windows by choosing “Cascade” or ‘Tile” in the [Window] menu.
“Cascade” arranges all report windows in an overlapping pattern. “Tile” arranges all
report windows in a tile pattern.

8.3 Select COM Port


See Section 2.2.3 Port Setting.

8.4 Reset COM Port


If the communication is disrupted during the report data transfer from the KR-7000P/
KR-7100P/ KR-8000PA/ KR-8100PA/ KR-8100P to Color Mapping 32, choosing “Reset
Port” in the [Port] menu can reset the communication port. Color Mapping 32 re-
initializes the communication port.

Page 52 TOPCON Corporation


Color Mapping 32
Software License Terms

PLEASE READ THE FOLLOWING "LICENSE TERMS" CAREFULLY BEFORE USING (OR
INSTALLING) THIS SOFTWARE!

ANY AND ALL TERMS AND CONDITIONS OF THE "LICENCE TERMS" SHALL BE DEEMED TO
BE ACCEPTED AND AGREED BY YOU IF YOU USE (OR INSTALL) THIS SOFTWARE.

This “Color Mapping 32" Software, including its instruction manual and other documents, contained in this
package comprises copyrightable works of TOPCON CORPORATION protected by copyright laws, and is
licensed, not sold.

TOPCON grants to you the right to use this “Color Mapping 32" Software under the terms and conditions
set out below.

LICENSE TERMS

1. LICENSE

Subject to the terms and conditions set out in this LICENSE TERMS, TOPCON CORPORATION
("TOPCON") hereby grants to you (the "USER") a non-exclusive and non-transferable license (the
"LICENSE") to use the "Color Mapping 32" including its instruction manual and other documents
contained in this package (separatively or collectively the "SOFTWARE") only on a single computer
which is a stand-alone or a terminal of a computer network (the “COMPUTER”). USER may not use the
SOFTWARE on more than one computer or computer terminal at the same time.

2. RESTRICTION

2.1 USER shall NOT:


(a) use the SOFTWARE on or with more than one computer or terminal at a time; or
(b) make any copy of the SOFTWARE, except for making one copy of the SOFTWARE
solely for back up purpose, or installing of the SOFTWARE into the COMPUTER,
or its internal or external hard disc drive; or
(c) sell, assign, exchange, pass, rent, lease or otherwise dispose of the SOFTWARE, or assign or sub-
license any right to use of the SOFTWARE to anyone else; or
(d) adapt, modify or alter the SOFTWARE, or merge any program with the SOFTWARE, or make any
derivative from the SOFTWARE; or
(e) remove, erase or make unclear any copyright notice of the SOFTWARE; or
(f) decompile, disassemble, analyze, or make reverse-engineering to, the SOFTWARE; or
(g) copy its instruction manual and other documents contained in this package.

2.2 In any event that USER exchanges, or sells, assigns, passes, rents, leases or otherwise dispose of to
any third party, or scraps the COMPUTER or any its internal or external hard disc drive or other
memory means in which the SOFTWARE has been installed, USER shall destroy or erase any and all
of the said installed SOFTWARE prior to the said exchange, etc.

Page 53 TOPCON Corporation


3. COPYRIGHT

The SOFTWARE (including its recording Media) is the exclusive property of TOPCON, and full title,
ownership and interests and copyrights and other intellectual property thereof shall remain vested with
TOPCON at any and all times.

4. TERM

The LICENSE shall commence on the date when the SOFTWARE is first used (or installed) by USER, and
shall remain in full force until the termination hereof pursuant to the provisions set out in Section 5.1
below.

5. TERMINATION

5.1 The LICENSE shall be forthwith terminated if USER fails to comply with any term or condition of
this LICENSE TERMS.

5.2 Upon any termination of the LICENSE, USER shall forthwith cease using the SOFTWARE, and
immediately destroy the original and any and all copies of the SOFTWARE (if any).

6. LIMITED WARRANTY

THE SOFTWARE IS PROVIDED ON AN "AS IS" BASIS WITHOUT WARRANTY OF ANY KIND.
TOPCON FURTHER DISCLAIMS ALL WARRANTIES, INCLUDING, WITHOUT LIMITATION,
ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE AND NONINFRINGEMENT.
THE ENTIRE RISK ARISING OUT OF, RESULTING FROM OR IN CONNECTION WITH THE USE
OR PERFORMANCE OF THE SOFTWARE REMAINS WITH THE USER. IN NO EVENT SHALL
TOPCON OR ITS SUBSIDIARIES, AFFILIATES, DISTRIBUTORS OR AGENTS BE LIABLE FOR
ANY CONSEQUENTIAL, INCIDENTAL, DIRECT, INDIRECT, SPECIAL, PUNITIVE OR OTHER
DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF
BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF MEDICAL, CLINICAL OR BUSINESS
INFORMATION, OR OTHER PECUNIARY LOSS, OR PERSONAL INJURY OR PROPERTY
DAMAGE) ARISING OUT OF, RESULTING FROM OR INCONNECTION WITH THIS LICENSE
TERMS OR THE USE OF OR INABILITY TO USE THE SOFTWARE.

7. COMPLIANCE WITH EXPORT CONTROL LAWS

Any and all exports or reexports of the SOFTWARE are subject to Japanese Exchange and Foreign Trade
Law and other Japanese related laws and regulations, and/or the United States Export Administration Act,
its implementing regulations as well as other U.S. export laws and regulations. Export or reexport of the
SOFTWARE in a manner contrary to either Japanese or U.S. law or regulation is strictly prohibited.
USER shall not export nor reexport to any country the SOFTWARE or any part or copy thereof without
prior obtaining all required authorization from the Japanese or the United States government.
TOPCON OR ITS SUBSIDIARIES, AFFILIATES, DISTRIBUTORS AND AGENTS SHALL NOT BE
RESPONSIBLE NOR LIABLE TO USER FOR ANY LIABILITY, LOSS, DAMAGE, PUNISHMENT,
OR PENALTY ARISING OUT OF OR RESULTING FROM USER ´ S VIOLATION OF OR
NONCOMPLIANCE WITH ANY JAPANESE OR U.S. EXPORT CONTROL LAWS OR
REGULATIONS.

Page 54 TOPCON Corporation


8. GOVERNING LAW

The validity, performance, construction, interpretation, effect and enforcement of this LICENSE TERMS
shall be governed by and under the laws of Japan.

9. ENTIRE AGREEMENT

This LICENSE TERMS constitutes the entire agreement between USER and TOPCON with respect to the
subject matter hereof, and shall supersede and cancel any and all prior written or oral agreements,
undertakings, negotiations, communications, commitments, representations, publications and advertisement,
etc. not specifically and expressly incorporated herein.

Page 55 TOPCON Corporation


TOPCON Medical Systems, Inc.

Color Mapping 32 Software


Instruction Manual
Version No. 1.24

TOPCON MEDICAL SYSTEMS, INC.


CORPORATE OFFICE: 37 West Century Road, Paramus, New Jersey 07652, U.S.A. Phone: 201-261-9450 Fax:201-387-2710 www.topcon.com

TOPCON OMNI SYSTEMS, INC.


Valley Forge Business Center, 2430 Blvd. of the Generals, Norristown, PA 19403, U.S.A. Phone:610-630-9200 Fax:610-630-6428 www.topconomni.com

TOPCON CANADA INC.


110 Provencher Avenue, Boisbriand, QC J7G 1N1 CANADA Phone:450-430-7771 Fax:450-430-6457 www.topcon.ca

TOPCON EUROPE B.V.


ESSE Baan 11, 2908 LJ Capelle a/d IJssel, THE NETHERLANDS Phone:010-4585077 Fax: 010-4585045 www.topconeurope.com
ITALY OFFICE
Via Montalcone 39, 20092 Cinisello B, mo(MI), ITALY Phone: 02-61-25-583 Fax: 02-61-25-927 www.topcon.it
DENMARK OFFICE
Ringstodvej 125, DK-4000 Roskilde, DENMARK Phone: 046-3275000 Fax: 046-327555
IRELAND OFFICE
Unit 69 Western Parkway Business Centre, Lower Ballymount Road, Dublin 12, IRELAND Phone: 01460-0021 Fax: 01460-0129

TOPCON S.A.R.L.
89, Rue de Paris 92585 Clichy, Cedex, FRANCE Phone: 01-4106-9494 Fax: 01-4739-0251

TOPCON DEUTSCHLAND G.m.b.H.


Gieberallee 31-33, 47877 Willich, GERMANY Phone: 49-2154-8850 Fax: 49-2154-885111 E-mail: [email protected] www.topcon.de

TOPCON SCANDINAVIA A.B.


Neongatan 2 S-43151 Molndal, SWEDEN Phone: 31-7109200 Fax: 31-268607 www.topcon.se

TOPCON ESPAÑA S.A.


Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern Barcelona, SPAIN Phone: 34-93-473-4057 Fax: 34-93-473-3932 www.topcon.es

TOPCON ( GREAT BRITAIN ) LTD.


Topcon House, Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX UNITED KINGDOM Phone: 01635-551120 Fax: 01635-551170 www.topcon.co.uk

TOPCON SOUTH ASIA PTE. LTD.


Blk 192 Pandan Loop, #07-01, Pantech Industrial Complex, SINGAPORE 128381 Phone: 62780222 Fax: 62733540 www.topcon.com.sg

TOPCON AUSTRALIA PTY. LTD.


Unit 18, 4 Avenue of Americas, Newington, NSW 2127 AUSTRALIA Phone: 61-2-8748-8777 Fax: 61-2-9647-2926 www.topcon.com.au

TOPCON INSTRUMENTS ( MALAYSIA ) SDN. BHD.


Excella Business Park Block C, Ground & 1st Floor, Jalan Ampang Putra, Taman Ampang Hilir, 55100 Kuala Lumpur, MALAYSIA Phone:03-42701068 Fax:03-4274508

TOPCON INSTRUMENTS ( THAILAND ) CO., LTD.


77/162 Sinn Sathorn Tower, 37th Fl., Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600, THAILAND Phone: 02-440-1152~7 Fax: 02-440-1158

TOPCON KOREA CORPORATION


2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-Gu, Seoul, 137-876, KOREA Phone: 02-2055-0321-7 Fax: 02-2055-0319 www.topcon.co.kr

TOPCON OPTICAL ( H.K. ) LTD.


2/F, Meeco Industrial Bldg., No.53-55 Au Pui Wan Street, Fo Tan Road, Shatin, N.T., HONG KONG Phone: 852-2690-1328 Fax: 852-2690-2221 www.topcon.com.hk

TOPCON CORPORATION BEIJING OFFICE


Room 8A Poly Plaza Building, 14 Dongzhimen Nandajie, Dongcheng District, Beijing, 100027, CHINA Phone:10-6501-4191~2 Fax:10-6501-4190

TOPCON CORPORATION SHANGHAI OFFICE


Room 901~903 Lippo Plaza No. 222, Huai Hai Zhong Lu, Shanghai, 20021 CHINA Phone: 21-62701877 Fax: 21-53966485

TOPCON CORPORATION BEIRUT OFFICE


P.O.Box 70-1002 Antelias, BEIRUT-LEBANON Phone: 961-4-523525/523526 Fax: 961-4-521119

TOPCON CORPORATION DUBAI OFFICE


c/o Atlas Medical FZCO., P.O. Box 54304, C-25, Dubai Airport Free Zone, UNITED ARAB EMIRATES Phone: 971-4-2995900 Fax: 971-4-2995901

TOPCON CORPORATION
75-1 Hasunuma-cho, Itabashi-ku, Tokyo, 174-8580 JAPAN.
Phone:3-3558-2520 Fax:3-3960-4214 www.topcon.co.jp

© 2004 TOPCON CORPORATION All Rights Reserved


Page 56 TOPCON Corporation
Printed in U.S.A.-TMS/04-04

You might also like