Task name

9-Dec-24
Duration Start Finish Predecess

FOR THE CONSTRUCTION OF


ETHIOPIAN MUSLIM
DEVELOPMENT AGENCY (EMDA)
mobilzotion (man power, material and equpments)
Description of Works
A. SUB STRUCTURE
Excavation & Earth Works
Clear the site to a depth of 200mm to remove
top soil.
Bulk excavation in ordinary soil to reduce level
to depth not exceeding 500mm .
Pit Excavation in ordinary soil for Foundation
Trench excavation in ordinary soil to a depth
not exceeding 1000mm from reduced ground
level.
Backfill under hard core, around footing pad
and around masonery wall with selected
material brought from outside, rammed and
rolled in layers not exceeding 200mm thick
until it attains its maximum compuction.
Load and cart away excavated material as per
engineers direction.
250mm thick hard core blinded and
consolidated with crushed stone.

2. CONCRETE WORK
Class C-5 concrete with minimum cement
content of 150kg/m3
a) Under footing
b) Under masonery
e)under ground floor slab
Class C-25 reinforced cocrete with minimum
cement content of 360kg/m3 filled in to form
work and vibreted around steel reinforcement,
form work and steel reinforcement shall be
measured separately.
a) In footing.
b) In foudation column
C) In ground floor Beams.
D)to 15 cm thick ground floor slab
E) 20cm thick shearwall
F) 20 cm thick ramp conerete
Provide, cut and fix in position sawn Zigba wood
or steel formwork which ever appropriate.
a) To footing pad.
b) To foudation column
C) to ground floor Beams.
D)to ground floor slab
E) to ramp
F) to 20cm thick shearwall
Mild steel reinforcement according to
structural drawings. Price includes
cutting, bending, placing in position and
tying wire. For super ans sub structure
a) Dia 6 mm deformed bar.
b) Dia 8 mm deformed bar.
c) Dia 10 mm deformed bar.
d) Dia 12 mm deformed bar.
e) Dia 14 mm deformed bar.

Construct Stone masonery wall wall bedded in


cement mortar (1:3) and both sides left for
pointing
a) Consiled Form view
b) Exposed face lafet
c)Masonery Retaining wall

B-SUPER STRUCTURE
1. CONCRETE WORK
Class C-25 reinforced cocrete with minimum
cement content of 360kg/m3 filled in to form
work and vibreted around steel reinforcement,
form work and steel reinforcement shall be
measured separately.
a) In elevation columns.
b) In Floor beams.
c) In Roof beams.
g) water tanker columns slab & beam
Provide, cut and fix in position sawn Zigba wood
or steel formwork which ever appropriate.
a) In elevation columns.
b) In Floor beams.
c) In Roof beams.
g) water tanker columns slab & beam
Mild steel reinforcement according to
structural drawings. Price includes
cutting, bending, placing in position and
tying wire. For super ans sub structure
a) Dia 6 mm deformed bar.
b) Dia 8 mm deformed bar.
c) Dia 10 mm deformed bar.
d) Dia 12 mm deformed bar.
e) Dia 14 mm deformed bar.
HCB WORKS
Construct 15cm thick HCB wall bedded in
cement mortar (1:3) and both sides left for
plastering

PLASTERING AND POINTING


Apply two coats of plastering in cement mortar
(1.3).
a) To external wall surfaces,
b) to exposed beams columns
C)To all internal wall surface
d) To all internal wall final coat jibsum
plastering
FLOOR FINISHING

Sepplay and Fix Non slippery ceramic floor


Finish, the size of ceramic determind by the
engineer according to the size of the room

20 cm x 2cm thick Marble to trush hold

23cm x 3cm thick marbel to window sill


PAINTING
Apply painting to

Quartz paint to external plastered surface

Plastic emulsion paint,Corridor &toilet part of


wall surface

Aluminium framed windows and curtain walls


Carpentary and Joinery
dia. 12 Equaliptus wooden truss horizintal and
vertical member
dia. 10 Euqualeptus diagonal member
5x7cm australian wooden perlin
Guge -32 corigated iron sheet roofing
Jibsum bord cieling
Wooden doors

6-SANITERY INSTALLATION
SANITARY EQUIPMENT (FIXTURES)
All fixtures which differs from that specified below is subject
to the owner's approval, based on samples,catalogues and
brochures presented by the Contractor. Unit Price shall
include all the necessary fixing brackets or hooks and all the
necessary assistance civil works such as chiseling of
walls,floors, beams and etc...

ALL FIXTURES ARE APPROVED EUROPEAN BRAND

Supply and fix hand wash basins with chrome plated cold
and hot water tap made of white vitreious china,complete
with mixing battery plug, chrome plated chain holder, P-
smell trap with connection pipe and with all other necessary
accessories.

Size :- 500 x 400 mm

Supply and fix wash down water closets made of white


vitreous china with plastic seat and cover including all
accessories.

Supply and fix toilet paper holder with chrome plated brass
wall flanged roll with chrome plated fastening screws and
other accessories.

Supply and fix crystal glass mirrors for toilets and wash
basins with copper back protection, size: 500/400 mm
including chrome plated brass mirror clips with chrome
plated screws and etc... for hand wash basins.

Supply and fix soap holder in white vitreous china of size


150 x 150 mm complete with the necessary fixing and other
accessories for hand wash basins.

Supply and fix floor drains made of made of polished steel


with 2cm water seal smell trap and all other necessary
fittings and accessories.
Size:- Dia. 50mm

Supply and fix electric water heater with a capacity given


below. Complete with all water proofing, mounting and
fastening material, safety, one-way valve and gate valve
and with all the accessories.
Capacity 80 Liter

Supply and fix pressed approved type fiber glass with


stainless steel bracing strip shower tray, including shower
head, mixing faucet, smell trap, etc.. Complete with all the
necessary accessories.
Size:- 700mm X 700mm
WATER SUPPLY PIPE LINE AND VALVES
Cold and hot water pipes shall be PPR pipes for cold and
hot water respectively, and be fixed to slabs, walls, beams
or etc…with metal straps or similar material. Unit price shall
include all assistance civil works and necessary fittings such
as T, bends etc. according to where shown on the drawing.
All water pipes shall be tested two times the working
pressure or 50 meters head, which ever is greater at the
expense of the contractor.

Supply and install PPR, PN-20 pipes to internal cold water


distribution system as shown on the drawing. Complete with
all the necessary fittings and accessories.
Dia. 20 mm
Dia. 32 mm

Supply and fix chrome service angle valves of approved


standard before hand wash basins, water closets and other
fixtures. Complete with unions, elastic water proofing, hand
wheels of normal quality and with all other necessary
accessories.

Dia. 15 mm

WASTE, VENT AND RAIN WATER PIPES AND


ACCESSORIES
All domestic waste, vent and storm water pipe lines shall be
comply to BS45/4:1983 and DIN 19531 uPVC pipes and
shall be provided with a minimum slope of 1.5%. Pipes and
necessary fittings shall be standard quality and be free from
damage during storage, construction and etc. Unit price
shall include all the necessary assistance civil works, such
as excavation cartaway, fixing or hanging to walls, beams or
slabs. etc., necessary fittings such as bends, Y, T, etc.
Storm water uPVC pipes shall resist the external
temperature and the quality shall meet the purpose.

Supply and lay internal uPVC, PN-6 waste pipes according


to where shown on the drawings. Complete with all the
necessary fittings.
Dia. 75 mm
Dia. 110 mm

Vent caps made of PVC, complete with all accessories


Dia. 75 mm

Supply and lay approved quality storm water uPVC, PN-4


down pipes according to where shown on the drawing.
Price shall include all the necessary connecting pieces
Dia. 110 mm
SITE WORK
Cold water pipes shall be HDPE pipes, and be laid in trench
as shown in the sanitary site drawing. Provide 100mm thick
sand bedding material rammed and tamped and 150mm
thick approved material to cover the pipe all as per the
typical trench section and detail. Unit price shall include all
assistance civil works and necessary fittings such as T,
bends etc. according to where shown on the drawing. All
water pipes shall be tested two times the working pressure
or 160 meters head, which ever is greater at the expense of
the contractor.

Supply and install HDPE pipes, PN-10 to site cold water


distribution system as shown on the drawing. Complete with
all the necessary fittings and accessories.
Dia. 20 mm
Dia. 25 mm
Dia. 32 mm

Construct slab covered ditch as per the detail drawing. Price


shall include excavation, cart away and all civil assistance
works.

Supply and uPVC, PN-6 pipe for waste water drainage from
the manhole to the septic tank with minimum slope as
shown on the drawing or natural ground slope which ever is
greater on a firm bed of sand 100 mm thick below and 200
mm thick above the crown of pipe in open ground.

Dia. 110 mm
Construct manholes on a sanitary sewer drainage systems
as where shown on the drawing in single brick on 150mm
thick reinforced concrete bottom slab in dia.10c.c150mm
both ways and 120mm thick reinforced cover slab in
dia.10c.c150 mm both ways. Price shall include all
assistance civil works and handle.

a) size: 600 x 600 mm


average depth = 850 mm

50m³ Septic Tank

7. ELECTRICAL INSTALLATION
Supply and install PVC sheathed power cable or wire of
type SIMENS NYY 0.6/1KV or approved equivalent
a) 4x10 sq.mm
b) 3x10sq.mm
c) 3x4 sq.mm
DISTRIBUTION BOARDS
All distribution boards, breakers, switches, accessories etc
should be genuine Legrad, ABB, Simens or approved
eqivalents complying with IEC standards. Distribution
boards should be flash/surface mounted madeof sheet
metal or hard plastic and have separte neutral and ground
busbars/phase bars. All unit in the distribution boards
should be labled to give the reference and duty of unit.

Flash mounted main distribution board MDB with locable


door, bus bar rating 400A , 3Ph earthing lead and with all its
accessories consisting of:-
6pcs m.c.b of 25A/3ph
5 pcs m.c.b of 63A/ph
1 pcs m.c.b of 32A/ph
1 pcs m.c.b of 20A/ph

Flash mounted main distribution board SDB B.Fwith locable


door, bus bar rating 20,3Ph, earthing lead and with all its
accessories consisting of:-
1 pcs m.c.b of 16A/ph
2 pcs m.c.b of 10A/ph

LIGHT POINT
Flush mounted light points fed through PVCconduits o f
13.5 mm diameter , including junction boxes with covers
insulating screw cap connectors. Type of Light fitting or
Approved Equivalent supplied, installed, connected and
tested as shown on the drawing

Chandlier Light Fitting

Suspended light Fitting

Flourecent light fitting 2x36W

Switches: 10A, 250V light switch, supplied, installed,


connected and tested, including box, plate, conduits,
conductors, drawboxes complete all as shown on drawings .

(TYPE LEGRAND DÉCOR OR EQUIVALENT)


Flush mounting single switch

Flush mounting double switch

Socket Outlet Legerand or Equivalent


Flush mounted socket outlets of 16A, 250V with protective
earth contacts supplied,installed, connected and tested fed
through PVC conductors of 3x2.5 sq.mm in thermoplastic
conduit of minimum diameter 16mm in/under surface
including junction box with cover and screw type insulating
connectors.

Ditto but 20A socket outlet for stove, mitad and washing mc

Ditto but socket outlet for frige, dryer and running


mc16A,1ph

Ditto but socket outlet for water heater,16A.1ph


Telephone
Telephone outlet: materials supplied, installed, cnnected
and tested complete including conduits, wires, J-boxes,
outlet complete all as shown on drawings.
TELEVISION
Television outlet: materials supplied, installed, cnnected and
tested complete including conduits, wires, J-boxes, outlet
complete all as shown on drawings.
Earthing
Earthing system: materials, supplied, installed, conneted
and tsted, complete, including conductros, busbar, straps,
test points, connectors, all necessary accessories, conplete
all as shown on drawings.
10-Dec-24

11-Dec-24

12-Dec-24

13-Dec-24

14-Dec-24

15-Dec-24

16-Dec-24

17-Dec-24

18-Dec-24

19-Dec-24
20-Dec-24

21-Dec-24

22-Dec-24

23-Dec-24

24-Dec-24

25-Dec-24

26-Dec-24

27-Dec-24

28-Dec-24

29-Dec-24
30-Dec-24

31-Dec-24

1-Jan-25

2-Jan-25

3-Jan-25

4-Jan-25

5-Jan-25

6-Jan-25

7-Jan-25

8-Jan-25
9-Jan-25

10-Jan-25

11-Jan-25

12-Jan-25

You might also like