OUTDOOR MIST COOLING

PRODUCT NAME
SYSTEMS FOR LARGE
AREAS

Humidification, Dehumidification
and Evaporative Cooling
Water treatment & high pressure pump
Pump station
A pump station and water treatment
system purifies the supply water
and pressurizes it for supply to the
pipework and nozzles. Water is supplied
at 70bar for optimum atomization on
its release as an aerosol.

A single pump station can treat and


deliver up to 1,300 litres per hour to
a distribution system. Multiple pump
stations can be combined to provide
unlimited humidification capacity.

An on-board digital control panel


provides a user interface for all
operational and hygiene functions
but the system can also connect to an
external building management system
(BMS) using popular BMS protocols.

Long lasting performance


through quality and design
Distribution systems

ML Flex ML Solo
This discreet nozzle can be mounted within a facade or Can be suspended from a ceiling or attached to a wall, the
exposed on a pipeline, with either single direction or bi- ML Solo can incorporate up to two nozzles. An integrated fan
directional nozzle heads. Humidification volume can be unit provides rapid evaporation and can offer up to 5kg/h
expanded without restrictions. and around 3.5kW of evaporative cooling.

ML Flex nozzles are made from high quality stainless steel,


are easy to install, and can be individually replaced within a
system if required without significant downtime.

to meet a project’s aesthetic and


Flexible design options and a performance specifications.
Condair high pressure humidification consultative approach to supporting
provides utmost performance and peace- clients, allows Condair evaporative Global engineering teams can support
of-mind for outdoor evaporative cooling cooling systems to perfectly integrate clients through the installation,
in high-profile public areas. The highest within a project’s architectural commissioning, training and on-going
quality components combine with a environment. Condair’s design maintenance necessary for operating
system design that focuses on hygiene department will work alongside a reliable and hygienic evaporative
management and long-lasting operation. architects and mechanical engineers cooling system.
Many environmental factors must be considered to calculate the potential of evaporative cooling

The potential of evaporative cooling


One kilo of moisture evaporated from a Condair’s experienced sales engineers
humidifier will provide around 0.68kW will work with a client’s team to
of cooling to the air. High pressure provide accurate projections of how
humidifiers have the capacity to release much cooling can be achieved given all
many thousands of kilos per hour, influencing factors.
delivering correspondingly high levels
of cooling to an area. The effect of relative humidity on evaporative cooling

However, the ambient humidity Starting relative Starting Humidity after Temperature after Actual cooling
humidity temperature humidification humidification effect
must be low enough to facilitate the
evaporation of the moisture and very 10%RH 26.5°C 18.5°C
high humidity must be avoided to
prevent discomfort (max. 15g/kg). 15%RH 28.5°C 16.5°C

20%RH 45°C 65%RH 32°C 13°C


Influencing factors
■ Ambient temperature 25%RH 33.5°C 11.5°C
■ Ambient humidity
■ Solar heat gain 30%RH 35°C 10°C

■ Shading
The lower the relative humidity is in an area, the more effective an evaporative
■ Surrounding environment cooling system will be in lowering the temperature. This is because more moisture
■ Airflow can be absorbed by the air, with correspondingly greater cooling.
■ Heat index (perceived temperature)

Contact Condair for a detailed cooling


performance calculation for your project
Hygienic design and operation must be a guiding principle in any evaporative cooling project

Hygienic operation
When introducing aerosols into a include ultra-violet sterilisation, reverse
public area, there is great responsibility osmosis, double RO, ion exchange or
to ensure those aerosols do not pose proactive antibacterial hygiene dosing
a risk to health. Microbes can grow in to combat microbial growth.
water, particularly when still and in
warm conditions. Evaporative cooling Inert materials are used in humidifier
systems must incorporate robust construction, such as stainless steel
features to control microbial growth. or polyester, and pipework is designed
with no “dead legs”, where water can
Condair humidifiers are designed and settle without flowing back to drain.
installed with hygienic operation as a
central guiding principle. Hygiene management must also Condair high pressure pump
include service and maintenance stations are manufactured to
Automated flush and drain cycles schedules, including disinfection and HACCP principles, from the food
ensure water cannot remain in the regular water testing for possible manufacturing industry.
system to stagnate, even during contamination levels, as a preventative
periods of non-operation. Water measure.
filtration and sterilisation systems are
also used to ensure the water being Condair can provide maintenance
supplied to the nozzle lines is pure. The support either directly or via training
type of water treatment incorporated of on-site technicians in best hygiene
into a system is project specific but can practise.
The highest quality components ensure the longest possible service lifetime

High quality for robust, long-lasting performance


A professional evaporative cooling All elements that convey water are
system in a high-profile public area made from stainless steel or inert
is a substantial investment and is plastics, including the pipework
frequently fully integrated into a connecting the nozzle network.
building’s architecture or mechanical
services infrastructure. It is therefore A stainless steel Danfoss high pressure
vitally important it provides a long pump is incorporated with hydraulics
service lifetime without the need that have a completely oil-free
to frequently replace expensive design. This minimises the required
components or require considerable maintenance and extends product
downtime. lifetime. Pumps are guaranteed for
8,000 maintenance-free hours of
Condair evaporative cooling systems operation.
are built using the highest quality
components to ensure the longest A Siemens controller provides intuitive
possible service lifetime. When user control over all functions.
elements do need replacing, system
design ensures it can be carried out
in a practical manner, as quickly and
conveniently as possible.
Let Condair’s experience guide you through an evaporative cooling project

Full turnkey solution


Every Condair evaporative cooling
system is delivered as a customer-
specific project.

A Condair sales engineer will work


with a client’s design team to provide
detailed calculations on potential
cooling capacity. Among other
elements this may take into account
geography, historic weather data and
Possible layout designs are then An outdoor evaporative cooling system
the surrounding environment. This
produced, which will include designed and delivered by Condair will
process can help to inform decisions on
information on integration with other provide the amount of cooling needed,
other architectural elements, such as
components and installation options. fit seamlessly with the surrounding
canopies and shading.
Other elements included in the design architecture, and have a long and
process are water management hygienic service lifetime.
planning to ensure hygienic
performance and maintenance
schedules for maximum longevity.
Our spray cooling projects include:

Al Masjid an Nabawi Haramain High Speed Railway


Prophet’s Mosque in Medina Stations at Medina and Makkah

Technical data
MLP RO 100 MLP RO 300 MLP RO 500 MLP RO 800
Humidification performance
100 275 440 750
(l/h)* at 50 Hz
Dimensions (H x W x D)
860 x 700 x 1600 860 x 700 x 1600 860 x 700 x 1600 860 x 700 x 1600
in mm for pump station
Dimensions (H x W x D)
Internal tank Internal tank 600 x 600 x 995 790 x 790 x 1250
in mm for external tank
Weight (kg) 125 130 240 270

3 x 400 VAC+GND 3 x 400 VAC+GND 3x400 VAC+GND+N, 3x400 VAC+GND+N,


+N, 1.8KW, 16A or +N, 2.5KW, 16A or 3.1KW, 16A or 3.8KW, 16A or
At 50 Hz
3 x 230 VAC+GND, 3 x 230 VAC+GND, 3x230 VAC+GND, 3x230 VAC+GND,
1.8KW, 16A 2.5KW, 16A 3.1KW, 20A 3.8KW, 20A

3 x 208 VAC+GND 3 x 208 VAC+GND, 3x208 VAC+GND, 3x208 VAC+GND


1.6KW 16A or 2.7KW, 16A or 3.1KW, 16A or 4.2KW, 20A or
At 60 Hz
3 x 480 VAC+GND 3 x 480 VAC+GND 3x480 VAC+GND, 3x480 VAC+GND,
1.8KW 16A 2.7KW 16A 3.1KW, 16A 4.2 KW, 16A

ML Solo

ML Solo 1 ML Solo 2

Humidification performance (l/h) 1.5 - 2.5 3–5

No. of nozzles 1 2

Operating pressure 50 - 70 bar 50 -70 bar

Operating voltage 24 VAC, 50 – 60 Hz 24 VAC, 50 – 60 Hz

Power input (W) 15 / 16 15 / 16

Weight (kg) 2 2

Dimensions (diameter/height) 180 x 150 x 170 mm 180 x 150 x 170 mm

Installation Ceiling or wall-mounted Ceiling or wall-mounted

ML Flex

ML FLEX

Humidification performance (l/h) 1–∞

Operating pressure 35 - 70 bar

Min. distance to ceiling 200 mm

Min. fogging zone 1.5 m