Number: 1310029SEL-018

Date: 05 Feb, 2018

Test Report

Applicant: DAEWOO INTERNATIONAL


Brand: MILEXUS
Country: CHINA
Model: ML-ED-560
Serial number: V21642BC400152
Model family: ML-RF-INOX-19, ML-RF-13, ML-RF-9,1, ML-RF-11,5, ML-RF-INOX-7, ML-RF-93L, ML-CF-100,
ML-CF-170, ML-CF-250, ML-CF-150, ML-CF-119, ML-CF-169, ML-CF-219, ML-ED-390L
Ability: 555L (19,6 feet 3)
Nominal voltage: 110-127 V
Stream: 3,5 A
Refrigerant: R134a/190 g

Purpose of the test.


Verification of the conformity of the technical characteristics of the model described in paragraph 2, with respect
to the subsections that are applicable to the equipment and that are specified in the Venezuelan Standard
COVENIN 178:1999 "Refrigerators and Freezers, requirements and test methods". These subsections are listed
below:

Table No. 1 requirements to check


5.6.- Grounding
5.6.1 Existence of grounding means
5.6.2 Ground continuity
5.6.3 Continuity through the hinges
5.6.4 Bridge conductors
5.6.4.1 Protection of the parts of the grounding system
5.6.4.2 Conductor gauge
5.6.4.3 Individual conductor serving as a bridge
5.6.5 Fixing the grounding bridges
5.6.6 Grounding reliability
5.6.7 Grounding design according to NVC200
5.6.8 Cooler plug
5.16.- Defrost device
5.16.1 Temperature resistance of defroster material
5.16.2 De-icer material corrosion resistance
5.16.3 Protection against mechanical damage defrost device
5.16.4 Defrost device cover
5.16.5 Test according to 6.5 (Insulation resistance)
5.16.6 Defrost device guard
5.16.7 Thaw flammability
5.16.8 Glass Protected Defrost Devices
5.18.- Leakage currents
5.18.1 Leakage currents and surfaces wetted by normal cleaning

Page 1 to 5

Intertek Testing Services Ltd .Zhejiang, Ningbo 5/F No. 6 Building, Lingyun Industry Park, No.1177 Tel: +86 574 8818
Branch Lingyun Road, Ningbo National Hi-Tech Zone, Ningbo, 3650
浙江天祥质量技术服务有限公司宁波分公司 China, 315000 Fax: +86 574 8818
宁波市高新区凌云路1177 号凌云产业园6 号楼5 层 3680
315000 www.intertek.com
www.intertek.com.cn
Number: 1310029SEL-018
Date: 05 Feb, 2018
Table 1 (continued). Requirements to check NVC 178:1999
5.20.- Pressure and temperature
5.20.1 Increase pressure and temperature
5.23.- Dielectric strength
5.23.1 Dielectric strength
5.33.- Mechanical strength of glass components
5.33.1 Strength of glass components

Tests to be carried out according to NVC178:2000


Test according to 6.5 (Insulation resistance)
Test according to 6.18 (Reliability of grounding)
Test according to 6.5 (Insulation resistance)
Flammability test according to 6.4 in thawing
Test according to 6.1 (Leakage currents and surfaces moistened by normal cleaning)
Test according to 6.2 (Increase in pressure and temperature)
Test according to 6.11 (Mechanical resistance of the cooling system)
Test according to 6.6 (Dielectric strength)
Test according to 6.7 (Resistance of glass components)

Preparation of the model and setup of the experiment.


Mechanical assembly:
In all tests, the model was placed on the wooden support with which it comes from the factory, in a vertical and
level position, on a vinyl floor with excellent insulating properties.
Electrical assembly:
To carry out the tests, the model was connected according to the 120 V electrical supply circuit, specified in the
standard for the measurement of leakage currents.
Test conditions:
The checks in which the environmental conditions are not specified in the standard, were made within the
following ranges:
* Temperature: 21°C - 31°C
* Relative humidity: 42% - 73%
* Atmospheric pressure 860 mbar – 865 mbar
Description of the test means.
To carry out the planned tests, the following instruments were available.
- Test equipment, Slaughter brand, model 6330.
- Alternating voltage injector equipment, Hipotronics brand, Model H306B-A.
- Multimeter, Fluke Brand, Model 337.
- Type K thermocouples.
- Fluke brand temperature meter, model 54ll.
- Infrared Temperature Meter, Fluke Brand, Model 66
- Piston for opening the refrigerator doors.
- Pneumatic system for piston actuation.
- LOGO 240 RC programmable relay.
- Environmental heater.
Page 2 to 5

Intertek Testing Services Ltd .Zhejiang, Ningbo 5/F No. 6 Building, Lingyun Industry Park, No.1177 Tel: +86 574 8818
Branch Lingyun Road, Ningbo National Hi-Tech Zone, Ningbo, 3650
浙江天祥质量技术服务有限公司宁波分公司 China, 315000 Fax: +86 574 8818
宁波市高新区凌云路1177 号凌云产业园6 号楼5 层 3680
315000 www.intertek.com
www.intertek.com.cn
Number: 1310029SEL-018
Date: 05 Feb, 2018

Testing method.
The checks were carried out according to the sequence of the chapters, paragraphs and subsections of the
reference standard.

Results.
The general results can be seen in Table 1, which is shown below:

Table 1. General Results


Measured Does
Situation, characteristic or
Paragraph Check Type value or Passed Refused not Earring
expected value apply
situation found
5.6.1 Existence of grounding means Inspection Adequate X
5.6.2 Grounding Continuity Inspection Adequate X
5.6.3 Continuity through the hinges Inspection ---- X
5.6.4 Bridge conductors Inspection ---- X
Protection of parts of the
5.6.4.1 Inspection Adequate X
grounding system
5.6.4.2 Grounding conductor gauge Adequate X
Single conductor serving as a
5.6.4.3 Inspection ---- X
bridge
5.6.5 Fixing the grounding bridges Inspection ---- X
5.6.6 Grounding reliability Trial See table 6 X
Grounding design according to
5.6.7 Inspection Adequate X
NVC200
5.6.8 Refrigerator plug Inspection Adequate X
5.16.1 Refrigerator material strength Inspection Adequate X
Freezer Device Cover Material
5.16.2 Inspection Adequate X
Corrosion Resistance
Protection against mechanical
5.16.3.1 Inspection Adequate X
damage of the freezing device
Protection against mechanical
5.16.3.2 Trial Adequate X
damage of the freezing device
5.16.4 Freezer device cover Measurement Adequate X
The insulation
Test according to 6.5
5.16.5 Trial did not X
(Insulation resistance)
deteriorate
5.16.6 Defrost device guard Inspection Adequate X
Flammability test according to
5.16.7 Trial See table 5 to 6 X
6.4 in thawing
Glass Protected Defrost
5.16.8 Inspection ----- X
Devices
5.18.1 Leakage current lf ˂ 0.75 mA Trial See table 2 X
Leakage current on wet
5.18.2 surfaces in normal cleaning lf Trial See table 3 X
˂ 0.5 mA
Increased pressure and
5.20.1 Trial See table 4 X
temperature
Dielectric strength, lfd ˂ 5,0 lfd=2,14 ± 0,5
5.23 Trial X
mA mA
5.33.1 Strength of glass components Trial Adequate X

Intertek Testing Services Ltd .Zhejiang, Ningbo 5/F No. 6 Building, Lingyun Industry Park, No.1177 Tel: +86 574 8818
Page 3 to 5
Branch Lingyun Road, Ningbo National Hi-Tech Zone, Ningbo, 3650
浙江天祥质量技术服务有限公司宁波分公司 China, 315000 Fax: +86 574 8818
宁波市高新区凌云路1177 号凌云产业园6 号楼5 层 3680
315000 www.intertek.com
www.intertek.com.cn
Number: 1310029SEL-018
Date: 05 Feb, 2018

The results of the tests for leakage current, leakage current on wet surfaces, temperature and leakage current
during defrosting are shown in tables 2 to 7.

Table 2. Leakage current measurement


(Expected value lf ˂ 0.75 mA)
S1 (off) S1 (off) S1 (on) S1 (on)
S2 (1) S2 (2) S2 (1) S2 (2)
−3 −3 −3
Measurement point 1𝑥10 (mA) 1𝑥10 (mA) 1𝑥10 (mA) 1𝑥10−3 (mA) Result
Grounding 187 ± 2,07 187 ± 2,07 89 ± 1,09 72 ± 0,92 According

Table 3. Leakage current measurement (wetted surfaces)


(Expected value lf ˂ 0.50 mA)
S1 (off) S1 (off) S1 (on) S1 (on)
S2 (1) S2 (2) S2 (1) S2 (2)
−3 −3 −3
Measurement point 1𝑥10 (mA) 1𝑥10 (mA) 1𝑥10 (mA) 1𝑥10−3 (mA) Result
Grounding 173 ± 1,93 171 ± 1,91 127 ± 1,07 66 ± 0,86 According

Table 4. Temperature test


Measurement point Expected value °C T (°C) ± 0,5 °C Result
Compressor 115-140 55,5 According
Capacitor 80 --- ---
Power cable 60 28,9 According
Ground wire 60 28,9 According
Compressor relay 75 43,7 According
Room temperature --- 27,6 ---

Table 5. Leakage current measurement (thaw test)


T refrigerator = 3,6 ± 0,5 °C T freezer = -16.1 °C I = 2,4 ± 0,3 A V = 119,9 ± 1 V (First defrost cycle)
Expected value lf ˂ 0,75 mA
S1 (off) S1 (off) S1 (on) S1 (on)
S2 (1) S2 (2) S2 (1) S2 (2)
−3 −3 −3
Measurement point 1𝑥10 (mA) 1𝑥10 (mA) 1𝑥10 (mA) 1𝑥10−3 (mA) Result
Grounding 169 ± 1,89 169 ± 1,89 66 ± 0,86 91 ± 1,11 According

Table 6. Leakage current measurement (thaw test)


T refrigerator = 6,7 ± 0,5 °C T freezer = -11.3 °C I = 2,4 ± 0,3 A V = 119,9 ± 1 V (Second defrost cycle)
(Expected value lf ˂ 0,75 mA)
S1 (off) S1 (off) S1 (on) S1 (on)
S2 (1) S2 (2) S2 (1) S2 (2)
−3 −3 −3
Measurement point 1𝑥10 (mA) 1𝑥10 (mA) 1𝑥10 (mA) 1𝑥10−3 (mA) Result
Grounding 169 ± 1,89 169 ± 1,89 66 ± 0,86 91 ± 1,11 According

Table 7, Resistance of the ground connection


(Expected value R < 0,1 Ω)
Type of test RΩ Result
According to 6.18.3.1 < 0,1 According
According to 6.18.3.2 < 0,1 According
According to 6.18.3.3 < 0,1 According
According to 6.18.3.4 < 0,1 According

Intertek Testing Services Ltd .Zhejiang, Ningbo 5/F No. 6 Building, Lingyun Industry Park, No.1177 Tel: +86 574 8818
Branch Lingyun Road, Ningbo National Hi-Tech Zone, Ningbo, 3650
浙江天祥质量技术服务有限公司宁波分公司 China, 315000 Fax: +86 574 8818
宁波市高新区凌云路1177 号凌云产业园6 号楼5 层 3680
315000 www.intertek.com
www.intertek.com.cn
Number: 1310029SEL-018
Date: 05 Feb, 2018

Page 4 to 5

The model described in this report meets the applicable requirements reported in this report that are required by
the standard.

--- End of test report ---

Authozed By:
Intertek Testing Services Ltd. Zhejiang, Ninbo Branch

___________________________________________
Peter Cheng
General Manager

Page 5 to 5