2.4.2 Limited current circuits, limit values Resistor 2 000 Ω ± 10%, Capacitance measuring device RB
2.6.3.4 Resistance of earthing conductors High current source with a voltage not exceeding 12 V RB
2.9.2 Humidity conditioning Chamber (91% Rh...95% Rh, 20...30 ° C) RB
2.10 Creepage distance/clearance/distance through Oscilloscope RB
4.3.6 Direct plug-in equipment Test equipment (see Fig. 11 of IEC 60065) RB
4.3.12 Flammable liquids Measuring equipment for concentration of flammable vapours S
4.3.13.2 Ionizing radiation Ionization meter (Annex H) S
4.3.13..3 Effect of UV radiation on materials Test equipment according to ISO 178, 179, 180, 527 and 8256 and S
according ISO 4892 series.
4.3.13.4 Human exposure to UV radiation Measuring equipment according to IEC 60825-9 S
4.3.13.5 laser radiation Several special equipment for laser classification(IEC 60825-1) S
4.4 Protection against hazardous moving parts Test finger (joint /rigid 30N, fig. 2A) RB
4.5 Thermal requirements RB
Voltage supply Single phase voltage supply systems/variability/adequacy RB
Three phase voltage supply systems S
Temperature (rise) Temperature recorder (multi-channel) RB
Thermocouples RB
Winding resistance (normally > 1,0 Ω 2-wire, 4-wire <1,0 Ω ). RB
Voltage Voltmeters (ac/dc) RB
High voltage meter (probe) RB
Current Currents (ac/dc) RB
Loading Loads (resistive) RB
4.5.5 Resistance to abnormal heat Ball pressure test apparatus according to IEC 60695-10-2 RB
Oven at least 125ºC
4.6.2 Bottoms of fire enclosure Distillate fuel oil as described in Annex A.3.2 S
4.6.4.2 Evaluation of larger openings Suitable tool (or tools) to simulate a straight metal object, 1mm in diameter, RB
length up to 13 mm
4.6.5 Adhesives for constructional purposes Oven up to 100 ° C RB
4.7.3 Materials, Tests see Annex A V-1, V-2, HF-2, 5V RB
Bunsen burner (9,5 ± 0,5 mm) RB
Gas for burner (~37 MJ/m3) RB
Oven for preconditioning RB
4.7.3.6 Materials used in high-voltage components Test of Annex A or test of 14.4 of IEC 60065 or needle flame test according RB
to IEC 60695-2-2
5.1 Touch current and protective conductor current Measuring instruments of Annex D RB
5.2 Electric strength Test equipment with the relevant voltage and tripping current. RB