techniques
Manometric method
Salt method:
The method is based on the fact that dried salt adhering to filter paper is
dissolved if the humidity of the surrounding air has reached a point equal to
the saturation humidity of the salt. If salts of different saturation humidities
are used, the aw level of a sample may be estimated.
Capacitive hygrometers
In capacitive hygrometers the capacitance of a polymer capacitor in a
measuring chamber changes as a function of humidity.
The measuring principle is based on a capacitor of very low mass
(rapid temperature adjustment) acting as a humidity sensor.
The dielectric is a hygroscopic polymer, which has a thin permeable
sputtered layer of metal on both sides.
Any alteration in relative humidity triggers a very rapid proportional
change in capacitance. The adjustment period for equilibrium
humidity in the measuring chamber is optimized by means of an
integral fan, the period being about 2.5 hours for foods.
Conductivity hygrometers
With conductivity hygrometers, the measurement of
electric impedance of a liquid hygroscopic substance is
used for direct reading of the relative humidity or water
activity in foods.
The liquid hygroscopic materials include salt solutions
or mixtures of various salt solutions. These sensors are
thus also called electrolytic cells.
The principle on which these cells are based relies on a
very precisely defined tiny quantity of the hygroscopic
material sandwiched between a pair of electrodes
mounted on a support plate.
Conductivity hygrometers
This substance tends towards equilibrium with the ambient humidity.
The electrolyte produces a defined water vapour pressure at its surface, depending on
its temperature and water content.
If there are differences between this water vapour pressure and that in a test chamber,
there is a water vapour exchange until the two pressures are identical.
The water content of the electrolyte thus changes, depending on the temperature and
water vapour pressure in the monitored surroundings, that is as a function of the
relative humidity of the air or, in equilibrium, of the aw level of a food.
Dew-point hygrometer
The freezing point of a food is closely linked in a physical/chemical sense with the
water activity of the product.
All those processes in a product that reduce the water activity also lower the
freezing point of the food. The point at which foods begin to freeze can be
measured and from this the aw level can be calculated.
The measuring system includes an electronic indicator module with a
microprocessor, a cylindrical sample chamber and a Peltier-cooling box at a
temperature of approximately -50ºC.
The higher the water activity of the sample, the shorter the measuring period. It is
between about 8 and 30 minutes with an aw range from 0.999 to 0.80.