Cda

DUAL IMPELLER CENTRIFUGAL ELECTRIC PUMPS


in cast iron

Cast iron dual impeller centrifugal electric pumps

APPLICATIONS
• Pressure boosting domestic plants
• Small-sale irrigation
• Moving non-aggressive liquids for civil and industrial use
• Washing plants and washing vehicles

TECHNICAL DETAILS
• Available with brass impeller (CDA 0.75 M GO, CDA 1.00 M GO).
• They can be inserted into machinery for industrial use

PUMP TECHNICAL DATA


• Maximum working pressure:
- 6 bar for CDA 0.75 - 1.00
- 10 bar for the rest of the range
• Maximum temperature of the liquid: 40°C for CDA 0.75 - 1.00,
90°C for the rest of the range
• G1 suction connection for CDA 0.75 - 1.00
PERFORMANCE CURVES (according to ISO 9906 Attachment A) • G1¼ for CDA 1.50 - 2.00 - 3.00, G1½ for CDA 4.00 - 5.50
• G1 discharge connection for CDA 0.75 - 1.00 - 1.50 - 2.00 - 3.00
G1¼ for CDA 4.00 - 5.50

MOTOR TECHNICAL DATA


• High efficiency IE2 motors starting from 0,75kW
• Self-ventilated 2 poles asynchronous motor
• Class of insulation F
• IP44 Protection degree
• 230V±10%, 50Hz single phase voltage,
230/400V ±10%, 50Hz three phase voltage
• Permanent capacitor inserted and thermo-amperometric protection
with automatic rearm incorporated for the single phase motor
• Protection under user’s responsibility for the three phase version

MATERIALS
• Cast iron pump casing
The contents of this publication must not be regarded as binding. EBARA Pumps Europe S.p.A. reserves the right to effect any modification it deems necessary, without prior notice.

• Mechanical seal in Carbon/Ceramic/NBR


• Impeller in PPE+PS reinforced with glass fibres for CDA 0.75 - 1.00, in
brass for the rest of the range
• Shaft in AISI 303 for CDA 0.75 - 1.00 -1.50 - 2.00 - 3.00, in AISI 304
for CDA 4.00 - 5.50
• Bracket in aluminium for CDA 0.75 - 1.00, in cast iron for the rest of
IDENTIFICATION CODE
the range
CDA 1.50 M • Seal housing disc in AISI 304 for CDA 0.75 - 1.00, in cast iron built-in
the motor bracket for the rest of the range
Single phaSe M
three phaSe t CONTROL PANELS
0.75
• 1EP
• 1EPBH
1.00
1.50 ACCESSORIES (on request)
power [hp]
2.00 • 5 litre 10 bar ¾ EPDM vessel
3.00 • 24 litre 8 bar 1” EPDM vessel
4.00 • 24 litre 10 bar 1” EPDM vessel
5.50 • PVC 5m key float with counter-weight
• PVC 10m key float with counter-weight
Model • SQUARE-D FSG-2 1.4÷4.6 bar G¼ F pressure switch
• FYG-22 2.8÷7 bar G¼ F pressure switch
• Presscomfort - Pressure regulator
• Press•o•Matic - Variable speed control system (230V±10% single
phase - power supply three phase 220V output – maximum motor
power 2.2 kW - 3 HP)
• E-drive - Frequency converter

Your Life, our Quality. Worldwide. 24 Residential


Cda
DUAL IMPELLER CENTRIFUGAL ELECTRIC PUMPS
in cast iron

PERFORMANCE TABLE
Model P 2
Q=Flow rate
Single phase Three phase l/min 20 40 50 80 90 100 110 140 170 190 210
230V 230/400V [HP] [kW] m3/h 1,2 2,4 3 4,8 5,4 6 6,6 8,4 10,2 11,4 12,6
H=Head [m]
CDA 0.75 M CDA 0.75 T 0,75 0,55 33,0 30,2 27,9 17,0 - - - - - - -
CDA 1.00 M CDA 1.00 T 1 0,75 39,5 37,0 35,2 27,0 21,0 - - - - - -
CDA 1.50 M CDA 1.50 T 1,5 1,1 50,8 48,8 47,1 38,4 33,4 27,5 - - - - -
CDA 2.00 M CDA 2.00 T 2 1,5 60,5 58,6 56,9 49,8 46,5 40,3 32,5 - - - -
- CDA 3.00 T 3 2,2 - 60,5 59,3 54,1 51,6 48,4 44,6 32,0 - - -
- CDA 4.00 T 4 3 - - 67,0 64,8 63,9 62,5 62,0 58,0 53,5 48,0 -
- CDA 5.50 T 5,5 4 - - 76,5 73,9 72,9 71,8 70,5 66,8 62,0 58,3 54,0
DIMENSIONS

The contents of this publication must not be regarded as binding. EBARA Pumps Europe S.p.A. reserves the right to effect any modification it deems necessary, without prior notice.
[1]= Three phase only
[2]= Single phase only

DIMENSIONS TABLE
Model Dimensions [mm] Weight
A B C D E F H H1 H2 H3 H4 M M1 N N1 R T V W S DNA DNM
[1] [2] [2] [1] [kg]
CDA 0.75M 183 336,3 179,8 8,3 73 9 227 97 130 - 198 42 40 140 180 57,5 PG11 - 6,8 9,5 G1 G1 13,8
CDA 0.75T 183 336,3 179,8 8,3 73 9 227 97 130 198 - 42 40 140 180 57,5 - PG11 6,8 9,5 G1 G1 13,8
CDA 1.00M 183 336,3 179,8 8,3 73 9 227 97 130 - 198 42 40 140 180 57,5 PG11 - 6,8 9,5 G1 G1 15,0
CDA 1.00T 183 336,3 179,8 8,3 73 9 227 97 130 198 - 42 40 140 180 57,5 - PG11 6,8 9,5 G1 G1 15,0
CDA 1.50M 209 407,8 218,3 8,3 86 9 265 110 155 - 242 48 40 155 195 65,5 PG13,5 - 12,3 9,5 G1¼ G1 24,2
CDA 1.50T 194 394,8 218,3 8,3 86 9 265 110 155 224 - 48 40 155 195 65,5 - PG11 12,3 9,5 G1¼ G1 24,9
CDA 2.00M 209 410,8 218,3 8,3 86 9 265 110 155 - 242 48 40 155 195 65,5 PG13,5 - 12,3 9,5 G1¼ G1 26,0
CDA 2.00T 194 408,0 218,3 8,3 86 9 265 110 155 224 - 48 40 155 195 65,5 - PG11 12,3 9,5 G1¼ G1 27,1
CDA 3.00T 194 410,8 218,3 8,3 86 9 265 110 155 224 - 48 40 155 195 65,5 - PG11 12,3 9,5 G1¼ G1 25,8
CDA 4.00T 228 467,3 225,3 12 95,5 12 308,5 133,5 175 265 - 57 50 180 230 71,5 - G1½ 12,0 12 G1½ G1¼ 46,8
CDA 5.50T 228 508,0 225,3 12 95,5 12 308,5 133,5 175 265 - 57 50 180 230 71,5 - G1½ 12,0 12 G1½ G1¼ 52,0
[1]= Three phase only
[2]= Single phase only

Your Life, our Quality. Worldwide. 25 Residential


Cda
DUAL IMPELLER CENTRIFUGAL ELECTRIC PUMPS
in cast iron

SECTIONAL VIEW

MATERIALS TABLE
Ref. Name Material Ref. Name Material
1 Pump body Cast iron 23 Capacitor [2] -
2 Pump body Cast iron 24 Filler cap Brass
3 Motor support [3] 25 Drain plug Brass
The contents of this publication must not be regarded as binding. EBARA Pumps Europe S.p.A. reserves the right to effect any modification it deems necessary, without prior notice.

4 Seal housing disc [4] 26 O-Ring NBR


6 Shaft [5] 27 Pump body gasket Cellulose fibres
7 Impeller [6] 28 O-Ring NBR
8 Impeller [6] 29 Intermediate disc Cast iron
11 Mechanical sealing Carbon/Ceramic/NBR 30 Seal spacer Brass
12 Motor case - 32 Key AISI 316
13 Motor cover Aluminium 34 Impeller nut [7] AISI 304
14 Fan PP 35 Bleed valve Brass
15 Fan cover Galvanised Fe P04 42 Foot PP
16 Terminal box - 52 Capacitor-holder box [2] ABS
17 Terminal box cover [1] Aluminium 53 Capacitor-holder box cover [8] ABS
18 Spray protector ring NBR 75 Washer Aluminium
19 Bearing (pump side) - 76 Washer Aluminium
20 Bearing (motor side) - 110 Motorprotector [9] -
21 Adjusting ring Steel C70 200 Screw (Pump body) Zn stainless steel Cl. 8.8 ISO 898-1
22 Tie-rod Galvanised Fe 42
[1]= For three phase only
[2]= For single phase only
[3]= Aluminium for CDA 0.75 - 1.00, cast iron for the rest of the range
[4]= AISI 304 for CDA 0.75 - 1.00, cast iron integrated Motor support for the rest of the range
[5]= AISI 303 (part in contact with the liquid) for CDA 0.75 - 1.00 - 1.50 - 2.00 - 3.00, AISI 304 (part in contact with the liquid) for the rest of the range
[6]= PPE+PS reinforced with fibreglass for CDA 0.75 - 1.00, brass for the rest of the range
[7]= Versione with impeller brass only
[8]= With gasket in NBR only for CDA 0.75 - 1.00 single phase models
[9]= Version CDA 1.50 - 2.00 single phase only

Your Life, our Quality. Worldwide. 26 Residential


Cda
DUAL IMPELLER CENTRIFUGAL ELECTRIC PUMPS
in cast iron

MECHANICAL SEAL MATERIALS TABLE


Ref. Name Material
A Rotating part Ceramic
B Fixed part Carbon
C O-Ring NBR
D O-Ring NBR
E O-Ring NBR
F Spring AISI 316
G Structure/frame AISI 304

DIMENSIONS
Single phase Three phase ØA ØB C
CDA 0.75 M CDA 0.75 T 15 26 29
CDA 1.00 M CDA 1.00 T 15 26 29
CDA 1.50 M CDA 1.50 T 18 30,9 32
CDA 2.00 M CDA 2.00 T 18 30,9 32
- CDA 3.00 T 18 30,9 32
- CDA 4.00 T 20 30,9 33
- CDA 5.50 T 20 30,9 33

ELECTRIC DATA TABLE


Model P 2
Efficiency Capacitor Efficiency (%) P 1
Absorbed Current
Single phase Three phase Single phase Three phase [A]
230V 230/400V [HP] [kW] Single phase Three phase µF V
c
η% Single phase Three phase Single phase Three phase
50% 75% 100% [kW] [kW] 230V 230V 400V
CDA 0.75 M CDA 0.75 T 0,75 0,55 - - 16 450 - - - 1,1 1,05 5,0 3,4 2,0
CDA 1.00 M CDA 1.00 T 1 0,75 - IE2 20 450 77,2 80,9 81,3 1,38 1,13 6,1 3,4 2,0
CDA 1.50 M CDA 1.50 T 1,5 1,1 - IE2 40 450 79,7 82,5 83,0 1,85 1,80 8,6 5,5 3,2
CDA 2.00 M CDA 2.00 T 2 1,5 - IE2 40 450 80,3 83,4 83,8 2,35 2,25 10,8 7,8 4,5
- CDA 3.00 T 3 2,2 - IE2 - - 83,0 84,4 83,8 - 2,74 - 8,5 4,9
- CDA 4.00 T 4 3 - IE2 - - 83,1 86,3 86,8 - 4,10 - 12,5 7,2
- CDA 5.50 T 5,5 4 - IE2 - - 84,3 87,2 87,8 - 4,56 - 15,1 8,7

NOISE DATA TABLE


Model P 2
L - dB(A)*
pA

Single phase Three phase


230V 230/400V [HP] [kW]

The contents of this publication must not be regarded as binding. EBARA Pumps Europe S.p.A. reserves the right to effect any modification it deems necessary, without prior notice.
CDA 0.75 M CDA 0.75 T 0,75 0,55
CDA 1.00 M CDA 1.00 T 1 0,75
CDA 1.50 M CDA 1.50 T 1,5 1,1
CDA 2.00 M CDA 2.00 T 2 1,5 <70
- CDA 3.00 T 3 2,2
- CDA 4.00 T 4 3
- CDA 5.50 T 5,5 4
* Mean value of several measures at 1m distance around the pump.
Tollerance ± 2,5 dB.

Your Life, our Quality. Worldwide. 27 Residential

You might also like