0% found this document useful (0 votes)
14 views6 pages

mizera

ere

Uploaded by

gohif99400
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views6 pages

mizera

ere

Uploaded by

gohif99400
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

AVEVA Everything3D™ (2.

1)
Supports Administration TM-1865

GT640 to GT700 Guide for Trunnions

Simple Guide Representation.

These user standards are created using Create Base


Component on the Support Editor form.

The three standard catalogue parameters have been


added, nominal bore (NB), outside diameter (OD) and
connection type (CONN) and 25 design parameters
have been created.

The following lists the parameters that have been preset. The plate length (PLEN), plate width (PWID) and
plate thickness (PTHK) will be obtained from the identified base plate. All other design parameters are set to
0 (zero) as shown in the form displayed above.

Number Description Dkey

1 Plate Length PLEN

2 Plate Width PWID

3 Plate Thickness PTHK

22 Minimum Insulation MNIN

23 Maximum Insulation MXIN

24 Minimum Temperature MINT

25 Maximum Temperature MAXT

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and
default values have been added as shown.

© Copyright 2015. 140 www.aveva.com


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Everything3D™ (2.1)
Supports Administration TM-1865

Point Sets

These have been created with the minimum points required by AVEVA E3D™ Supports. These are:

P-Point Description

1 Arrive Point

2 Leave Point

3 Bottom of Pipe (BOP) -5mm, i.e. bottom of the ancillary geometry -5mm

9 BOP (Including geometry if required), i.e. bottom of the ancillary geometry

10 Left of Pipe

11 Right of Pipe

12 BOP

The diagram below shows the position and directions of the p-points, P1 and P2 are arriving and leave points
along the centreline of the pipe.

 The AVEVA E3D™ Supports default p-points provided cannot be deleted or modified, but additional
ppoints can be created if required.

© Copyright 2015. 141 www.aveva.com


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Everything3D™ (2.1)
Supports Administration TM-1865

Data Sets

These have been created with the minimum number of elements required by AVEVA E3D™ Supports. These
are:

Data Name Description DataKey DefaultProperty

/Prefix-DESC Support Standard DESC 'AT500'


(BEF (AFT (ATTRIB PPRO of DATA
Standard Replacement
/Prefix-RNAM RNAM /MDS/ATTA/DEFAULTS/AT500/GEN/CCOD , ‘(‘’’)
Name
, ‘’’ )’ ) )
/Prefix-PA1 Nominal Bore NB PARA 1

/Prefix-PA2 Outside Diameter OD PARA 2

/Prefix-PA3 Connection Type CONN PARA 3


( ATTRIB DENS of 1 OF 1 of :MDSMatRef *
/Prefix-WEIG Component Weight WEIG ATTRIB NVOL / 1000 / 1000 / 1000 * VVAL
!!MDSWEIUNIT )
( ATTRIB DESC of :MDSMatRef )
/Prefix-MATR Component Material MATR

( TRIM ( DIST ( NOMBORE ( false, ATTRIB


/Prefix-CODE Support Code CODE CPAR[1 ] ) , false , false , true , 4 , false ) ) + '-' +
ATTRIB PROPRNAM)
(BEF (AFT (ATTRIB PPRO of DATA
MDS Configurable /MDS/ATTA/DEFAULTS/AT500/GEN/DESC , ‘( ‘’’ )
/Prefix-CDES CDES
Description ‘’’ ) ) )

/Prefix-DP1 Design Parameter 1 Unset DESP[1]

Where /Prefix is /Standard-DATA- e.g. /AT500-DATA-DESC and the standard used as an example above is
AT500.

The Supports administrator can add/modify the data set as necessary.

Project Catalogue for User Defined Ancillaries

The catalogue items for the user defined ancillaries have been created in the ranges detailed below within the
MDU/CATA database in AVEVA Sample project (APS). This database contains all the catalogue elements,
i.e. SCOM, GMSE, PTSE, DTSE and SDTE, where the user will modify the GMSE to suit their requirements.
The specification components for ALL the user defined ancillaries are in the /MDS specification in the AVEVA
E3D™ Supports project, which MUST NOT be modified by users.
Current Range AVEVA E3D™ User Range AVEVA E3D™
Standard Description Supports Project Supports Project
From To From To
AT Ancillary AT01 AT115 AT500 AT700
LT Lug LT01 LT16 LT500 LT700
BT U-Bolt BT01 BT11 BT500 BT700
AN Anchor AN01 AN18 AN500 AN700
GT Guide GT01 GT50 GT500 GT700
ST Stop ST01 ST33 ST500 ST700

© Copyright 2015. 142 www.aveva.com


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Everything3D™ (2.1)
Supports Administration TM-1865

The MDU/CATA catalogue hierarchy has been created as shown on the previous page for a size range of
8mm (1/4") to 1200mm (48") in the bore sizes shown below:

Metric NB Imperial NB Actual OD OD


8 1/4 13.7 14
15 1/2 21.3 21
20 3/4 26.7 26
25 1 33.4 33
32 1.1/4 42.2 42
40 1.1/2 48.3 48
50 2 60.3 61
65 2.1/2 73 73
80 3 88.9 89
100 4 114.3 115
125 5 141.3 141
150 6 168.3 169
200 8 219.1 220
250 10 273 273
300 12 323.8 324
350 14 355.6 358
400 16 406.4 407
450 18 457 457
500 20 508 508
550 22 559 559
600 24 610 610
650 26 660 660
700 28 711 711
750 30 762 762
800 32 813 813
850 34 864 864
900 36 914 914
950 38 965 965
1000 40 1016 1016
1050 42 1067 1067
1100 44 1118 1118
1150 46 1168 1168
1200 48 1219 1219

© Copyright 2015. 143 www.aveva.com


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Everything3D™ (2.1)
Supports Administration TM-1865

Modifying the User Defined Ancillary Standard

The administrator uses the standard PARAGON Pipework Application to modify the required elements within
the MDU catalogue database, i.e. MDU/CATA

Within the MDU/CATA database, the following should not be deleted or modified (including name change):

CATREF (Catalogue Reference)

PTREF (P-Point Set Reference) (see Note below)

GMREF (Geometry Set Reference) (see Note below)

DTREF (Data Set Reference) (see Note below)

 Although the MDU/CATA default p-points provided cannot be deleted or modified, additional p-points
can be created. Also, geometry can be added to the geometry sets, and additional properties included
as necessary.

Example User Defined High Pressure Support.

The following is an example of a simple High Pressure Support.

 Some basic Piping Cats and Specs knowledge is assumed during this example.

Modifying the support geometry


The support designer can create any shape but it should
be kept simple.

Enter the Paragon Module of the Training


Project as a Support Administrator using the
following details.

Project: Training (TRA)

Username: A.SUPPORTADMIN

Password: A

MDB: A-SUPPORTS

Module: Paragon

Click the Paragon Tile.

© Copyright 2015. 144 www.aveva.com


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Everything3D™ (2.1)
Supports Administration TM-1865

From the Catalogue Explorer, navigate to support CATE


ATTA-AT501.

Enter the Piping application Select PIPING for the Application


Pull-down

Select Category from the Modify Group of the CATALOGUE Tab.

The Support can now be modified as required to suit the Project requirements. Navigate to AT501-4.100 from
the bottom section of the Model View window.

© Copyright 2015. 145 www.aveva.com


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.

You might also like