Asset 1st Batch Level III
Asset 1st Batch Level III
Mirpur-2, Dhaka-1216
Trade: PLC
ASSET 1st Batch (January-April)-2024, Level - III
Date: 27-04-2024
✓
1. What is equivalent of 1KΩ ?
a) 1000Ω b) 100Ω c) 10Ω d) 10000Ω
2. Which one is the write platform to ping ?
a) Command window b)control panel c) command prompt d) control window
3. The output voltage of thermocouple is ….
a) DC Voltage b) AC Current c) AC Voltage d) DC mVoltage
4. What is ?
a)Break contact b) Make contact c) Analog contact
5. What is (/) ?
a) Coil b) Inverted coil c) NO d) NC
6. ……. is not a signal control element?
a) Pneumatic electric b) Potentiometer c) Solenoid Valve d)
7. Which one is the above sign?
a) Sine wave b) Square wave c) Triangle d) Exponential
8. Draw the square wave.
Ans:
Oral Question
1. Temperature sensor, Level Sensor, RPM sensor
2. 0-10V DC and 4-20mA
3. Inverter/VFD, Analog valve
4. Actually, the mechanism of the relay and magnetic contactor are same but relay is
used to handle low current and to make some logical flow wherein Magnetic
Contactor is used to handle the heavy load i,e 3 phase induction motor.
5. The main function of the timer is to apply delay between its input signal state and
output signal state. If the delay applied to its input ON state that to ON state that is
called ON delay timer.
On the other hand, if the delay applied to its input OFF state to output OFF state
that is called Off delay timer.
6. I/O interface, CPU, Memory, Programming tool.
Bangladesh German Technical Training Center
Mirpur-2, Dhaka-1216
Trade: PLC
ASSET 1st Batch (January-April)-2024, Level - III
Date: 05-05-2024
A) B) C) D)√
A) √ B) C) D)
A) B) √ C) D)
A) Programmable B) Peripheral
C) Periodic D) Pneumatic
12. What is ?
A) B) √ C) D)
(Answer in short)-
Ans: It's a latching circuit or an inter-locking circuit. When push switch S1 pressed the relay K1
will on and remain ON until the push button, NC is pressed.
Ans: Ladder diagram are specialized schematics commonly used to document PLC logic.
22. How would you explain device manager?
Ans: Device manage is a control panel in Microsoft windows operating system. It allows users to
view and control the hardware attached to the computer.
Ans: On-off control uses a feedback controller that switches abruptly between two states.
Ans: Set point is the target value at which a controller attempts to maintain the process variable.
Ans: A feedback controller measures the output of a process and then manipulates the input as
needed to drive the process variable toward the desired setpoint.
Ans: A process variable, process value or process parameter is the current measured value of a
particular part of a process which is being monitored or controlled.
Ans: Motor is an electrical machine that convert electrical energy into mechanical energy.
Ans: A Magnetic Contactor is a special type of relay used for Switching and electrical circuit
ON or OFF.