PRODUCT OVERVIEW SHEET: Hybrid Composite Synthetic Concrete (HCSC)

Hybrid Composite Synthetic Concrete (HCSC) is a high performance, structural polymer concrete material with hybrid co-polymer
resin binder and graded silica-quartz aggregates specifically formulated to meet unique and demanding field-cast concrete
applications in bridge construction with an emphasis on bridge deck elements like precast closure pours, large full depth bridge deck
patching, full depth bridge deck joints, composite deck stiffening overlays, orthotropic steel deck bonded thick wearing surfaces and
more. HCSC consists of composite, natural, and industrial components with properties optimized for mechanical effectiveness,
compatibility with adjacent materials, ease of installation and rapid strength development in a wide range of conditions, and
complete elimination of degradation in natural service environments.

Compared to PPC-1121 Polyester Polymer Concrete HCSC has significantly increased structural stiffening capabilities including
higher Tensile Strength, higher Stiffness, lower Shrinkage, greater Abrasion Resistance, lower Creep and better steel reinforcement
development properties required for demanding structural loading applications.

Compared to High Strength Epoxy Grouts HCSC is field-catalyzed for <4 hrs traffic return at 40-100 F placement temperatures, has a
lower CTE similar to concrete, creates composite action transition zones at the bond line using a High Molecular Weight
Methacrylate (HMWM) saturating primer, and is UV and hydrolytically stable.

Compared to Ultra High Performance Concrete (UHPC) HCSC is more flexible in the linear elastic zone, has 0 coulombs permeability
to moisture and chlorides, ½ the setting shrinkage strain, equals in abrasion resistance and provides structural composite behavior in
<4 hours at 30-100 F placement temperatures. HCSC suits existing UHPC dimensional and rebar details but does not require top
forming, diamond grinding, post-curing or temperature conditioning. HCSC can be overlaid with PPC-1121 more rapidly and
accommodates differential deflections during placement to develop early rebar engagement strength.

In all applications HCSC is installed using existing surface preparation, installation, and equipment specifications for Polyester
Polymer Concrete (PPC-1121). Volumetric Mobile Truck Mixers designed for PPC-1121 are compatible for HCSC placement without
modifications allowing placement production rates up to 20 CY/HR/Truck.

Hybrid Composite Synthetic Concrete (HCSC) Properties


Compressive Strength ASTM C39 8,000 psi, min
Tensile Strength ASTM C1583, modified 1,500 psi, min
Flexural Strength ASTM C78, (third-point, 4x4x12) 2,000 psi, min
Young’s Modulus ASTM C469 ~ 2,500 ksi
CTE ASTM T336 < 11 x 10-6 in/in/°F
Linear Shrinkage ASTM C157
(initial length @ 4 hours) 400 microstrain
(initial length @ 24 hours) 90 microstrain
Abrasion Resistance ASTM C944 (22 lbs, 2 min) < 0.3 grams lost
Permeability ASTM C1202 0.0 coulombs
Rebar Development NY 701-14E Pullout test for UHPC 6 db, rebar yielded
Length 7-day cure, conditioned for 24 hrs @ 120 °F,
#6 @ 5” and #4 @ 3” embedment
Scaling Resistance ASTM C672 Not applicable
Alkali-Silica Reaction ASTM C1260 Not applicable

Kwik Bond Polymers, LLC 923 Teal Drive, Benicia, CA 94510 [email protected]