FFT Report

Date/Time Vert at 17:46:07 November 20, 2024 Serial Number UM11585 V 10-87 Micromate DIN
Trigger Source Geo: 1.000 mm/s, Mic: 68.95 pa.(L) Battery Level 3.8 Volts
Range Geo: 254.0 mm/s Unit Calibration June 20, 2022 by RGN Zagreb
Record Time 9.604 sec (Auto=3Sec) at 2048 sps File Name UM11585_20241120174607.IDFW
Operator/Setup: Operator/OSOJNICA.mmb Scaled Distance 79.1 (500.0 m, 40.0 kg)

Notes Extended Notes


Location: Kamenolom Osojnica
Client: Limunkop d.o.o.
User Name: Tim-Z doo Siroki Brijeg
General: MINIRANJE KAMENOLOMA

Tran Dominant Frequency = 196.2 Hz., Amplitude = 0.034, PPV from Event = 2.435 mm/s
0.04

0.02

0.0
2 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250

Vert Dominant Frequency = 196.2 Hz., Amplitude = 0.030, PPV from Event = 6.763 mm/s
0.04

0.02

0.0
2 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250

Long Dominant Frequency = 78.75 Hz., Amplitude = 0.025, PPV from Event = 2.223 mm/s
0.04

0.02

0.0
2 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250

MicL Dominant Frequency = 2.500 Hz., Amplitude = 0.001, PSPL From Event = 0.078 pa.(L)

0.0
2 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
Frequency (Hz.)

Printed: November 27, 2024 (V 10.72 - 10.72) Format © 1995-2014 Xmark Corporation