06.01.2022 Igims Rio - Transformer - Boq (External)
06.01.2022 Igims Rio - Transformer - Boq (External)
TENDER DOCUMENTS
TRANSFORMER
(Schedule of Quantities )
Date: 28/12/2021
ARCHITECT
SERVICE CONSULTANT
A TRANSFORMER
Set 3
BATTERY CHARGER ;
Supply, installation, testing and commissioning of 200 AH
capacity 220 volts DC hermetically sealed maintenance
free lead acid batteries duly charged including battery
charger unit with provisions of Boost Charing, and Float
2.0 MR charging. Suitable for 240 V, including DC DB single
phase + 10% AC, 50 Hz supply consisting of 63A DP MCB
as incommer and 8No. 20A DP MCB as outgoing as per
attached specifications.
Set 1
Amount
S. No. Description of item Schedule Item Non-Schedule
DSR - 2018 Item
0.00 cum
slab 1.00 1 4 2.865 2.9 0.4 13.29 cum
slab 1.00 1 4 1.5 2.9 0.4 6.96 cum
slab 1.00 1 4 2.665 2.95 0.4 12.58 cum
slab 1.00 1 4 1.87 1.22 0.4 3.65 cum
slab balcony 1.00 1 4 1.65 1 0.4 2.64 cum
slab balcony 1.00 1 4 1.75 1 0.4 2.80 cum
slab stair lobby 1.00 1 2 2.4 1.23 0.4 2.36 cum
landing 1.00 1 2 2.4 1.22 0.4 2.34 cum
mumty 1.00 1 1 5.7 2.37 0.4 5.40 cum
0.00 cum
52.00 cum
28.00 sqm
WATER TANK
wall horizontally outer 1 2 1 5.32 2 2.75 58.52 sqm
wall vertically outer 1 2 1 2.455 2 2.75 27.01 sqm
middle wall vertically 1 3 1 2.455 2 1.35 19.89 sqm
105.00 sqm
Suspended floors, roofs, landings, balconies and
5.9.3 sqm
access platform
slab 3.00 1 4 2.865 2.9 99.70 sqm
slab 3.00 1 4 1.5 2.9 52.20 sqm
slab 3.00 1 4 2.665 2.95 94.34 sqm
slab 3.00 1 4 1.87 1.22 27.38 sqm
slab balcony 3.00 1 4 1.65 1 19.80 sqm
slab balcony 3.00 1 4 1.75 1 21.00 sqm
slab stair lobby 3.00 1 2 2.4 1.23 17.71 sqm
landing 3.00 1 2 2.4 1.22 17.57 sqm
mumty 1.00 1 1 5.7 2.37 13.51 sqm
water tank top & bottom slab 1.00 2 1 4.92 2.455 24.16 sqm
387.00 sqm
5.9.4 Shelves Sqm
kitchen 3.00 4 1 2.185 0.6 15.73 Sqm
toilet 3.00 4 1 0.6 0.6 4.32 Sqm
20.00 Sqm
Sqm
Terrace Beams
Along Grid 1/ A-I 1 1 1 4.378 0.23 0.32 3.81 sqm
1 1 1 4.378 0.23 0.32 3.81 sqm
Mumty
Along Grid 4/ A-I 1 1 1 2.485 0.23 0.32 2.16 sqm
1 1 1 2.665 0.23 0.32 2.32 sqm
up to plinth
column padastal 1 1 26 0.6 0.75 0.3 21.06 sqm
column 1.00 1 26 0.3 0.45 1.3 50.70 sqm
Column From Gf to Top. 1 1 26 0.3 0.45 9.45 368.55 sqm
Mumty 1 1 6 0.3 0.45 3.15 28.35 sqm
Terrace 1 1 19 0.3 0.45 3.15 89.77 sqm
WATER TANK
wall horizontally outer 1 2 1 5.32 0.2 2.75 5.85 cum
wall vertically outer 1 2 1 2.455 0.2 2.75 2.70 cum
middle wall vertically 1 3 1 2.455 0.2 1.35 1.99 cum
569.00 sqm
Stairs, (excluding landings) except spiral-staircases.
5.9.7 sqm
5.9.4 Shelves
cub board 3 4 3 1 0.6 0.05 1.08 cum
0.00 cum
1.00 cum
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in position
5.22 and binding all complete upto plinth level.
0.00 cum
54.00 cum
Lintels, beams, plinth beams, girders, bressumers
5.9.5
and cantilevers.
First & Second Floor Beam
Along Grid 1/ A-I 2 1 1 4.378 0.23 0.45 0.906246
2 1 1 4.378 0.23 0.45 0.906246
Terrace Beams
Along Grid 1/ A-I 1 1 1 4.378 0.23 0.45 0.453123
1 1 1 4.378 0.23 0.45 0.453123
Mumty
up to plinth
column padastal 1 1 26 0.6 0.75 0.3 3.51 cum
column 1 1 26 0.3 0.45 1.3 4.56 cum
D 3 4 1 12.00 each
D1 3 4 1 12.00 each
D2 3 4 1 12.00 each
SL 3 8 1 24.00 each
main door 3 1 1 3.00 each
63.00 each
Providing and fixing special quality chromium plated
brass cupboard locks with six levers of approved
9.90 quality including necessary screws etc. complete.
W 3 4 1 2 24.00 each
cub board 3 4 1 2 24.00 each
48.00 each
9.97.5 100x10 mm each
V 3 6 1 2 36.00 each
36.00 each
10.14.1 Profile B
Fixing with adjustable lugs with split end tail to each
10.14.1.1
jamb
D 3 4 1 5.4 64.80 metre
D1 3 4 1 5.1 61.20 metre
D2 3 4 1 4.95 59.40 metre
185.00 metre
Steel work in built up tubular ( round, square or
rectangular hollow tubes etc.) trusses etc. including
cutting, hoisting, fixing in position and applying a
10.16 priming coat of approved steel primer, including
welding and bolted with special shaped washers etc.
complete.
21
Providing and fixing mild steel round holding down
10.19 bolts with nuts and washer plates complete. kg
gf to 2nd floor
v bed room 3 4 1 2.90 2.90 100.92 sqm
v living room 3 4 1 2.70 2.95 95.58 sqm
v passage 3 4 1 1.02 1.74 21.24 sqm
c kitchen 3 4 1 1.50 1.89 33.93 sqm
c balcony-1 3 4 1 1.50 0.93 16.65 sqm
c utility balcony 3 4 1 1.70 0.95 19.38 sqm
c toilet 3 4 1 2.10 1.35 34.02 sqm
k lobby 3 1 1 3.78 2.40 27.18 sqm
k stair landing 3 1 1 2.40 1.20 8.64 sqm
k stair tread 3 1 21 1.20 0.30 22.68 sqm
ch ramp 1 1 1 4.87 1.34 6.50 sqm
k stair ground 1 1 1 4.20 2.40 10.08 sqm
0.00 sqm
0.000 0.00 sqm
1665.00 sqm
INVENTRY
FOR EXHUST
Exhaust FAN
16A SWITCH
TELEPHONE
6A SWITCH
LIGHT(20w)
18W DOWN
SEC. POINT
6A SOCKET
SEC. LIGHT
(1200mm)
PR. POINT
PR. LIGHT
( 300mm)
CONTROL
CONTROL
LIGHTER
SWITCH
SOCKET
SOCKET
SOCKET
AREA DESCRIPTION
16A AC
POINT
S.No.
TUBE
2X6A
PTS.
PTS.
MCB
MCB
FAN
A EXTERNAL ROOMS
1 HT METER ROOM 3 2 1 1
2 SUBSTATION 1 1 12 3 9 4 1
3 HT PANEL ROOM 3 2 1 1
4 STAIRCASE 6 2 4
5 JE ROOM 1 1 1 4 2 2 3 1 1
6 STORE ROOM 1 2 1 1 1 1 1
7 UPS & BATTERY ROOM 1 4 2 2 1 1 2 1
8 TOILET 1 2 2 1
9 POL ROOM 4 2 2 1 1 2 1
10 PLUMBING PLANT ROOM 1 1 2 4 2 1 1 1
TOTAL 3 4 3 10 36 16 18 4 4 4 6 15 4 3
10% ADD 0.3 0.4 0.3 1 3.6 1.6 1.8 0.4 0.4 0.4 0.6 1.5 0.4 0.3
GRAND TOTAL 3 4 3 11 40 18 20 4 4 4 7 17 4 3
TOTAL 124
2 MCB Control
TOTAL 199