Control Circuit Wiring Diagram

Goodrive380L Series
Elevator AC Drive

I/O Expansion Board Wiring Diagram

20220725(V1.0)
Introduction Product Specification PG Cards
Goodrive380L series elevator dedicated VFD is developed by using the new INVT control platform.
Function Specifications Model Picture Category Description
Goodrive380L adopts advanced frequency conversion vector control technology, and has made modular and customizable
innovations on the basis of traditional frequency converters to meet complex individual needs. INVT integrates many years of Rated voltage: AC 380V EC-PG101-05 5V Incremental PG card Special for incremental encoder,
PG card for power supply output :-05(4.75~7V),
industry experience and equips it with various motors and encoders, so that it can be widely used in freight elevators, passenger Allowed input working voltage range: EC-PG101-12 12-15V Incremental PG card
Rated input voltage(V) asynchronous motor -12(11.75~16V), -24(24V±5%)
elevators and other fields. Powerful configuration and performance enable it to meet more precise usage requirements and provide AC 1PH 220V(-15%)–240V(+10%) EC-PG101-24 24V Incremental PG card
Power
AC 3PH 380V(-15%)–440V(+10%) Special for SIN/COS encoder like ERN1387,
more competitive solutions. input EC-PG102-05 Sin/Cos PG card
Rated input current(A) See “Model Selection” PG card for power supply output 5V±5%, 300mA
50Hz or 60Hz synchronous motor Special for ENDAT/SSI encoder like ECN1313,
Rated input frequency(Hz) EC-PG106-05-T Absolute encoder PG card power supply output 5V±5%, 300mA
Allowed range: 47–63Hz
Features Rated output voltage(V)
Rated output current(A)
Equal to the input voltage, the error is less than 5%
See “Model Selection”
Power
Rated output power(kW)
● Standard built-in LCD interface output


Built in CANopen
Built in incremental PG card
Rated output frequency(Hz)
Control mode
0–400Hz
Sensorless vector control, closed-loop vector control
Dimensions
● Removable terminal board Maximum output frequency 400Hz
● Ultra thin flat design(easy for MRL or integrated control panel) For open-loop vector control: 1:200
Adjustable-speed ratio
● Flat or vertical book type installation For closed-loop vector control: 1:1500
● Built in STO (SIL3) Speed controlaccuracy
± 0.5% (open-loop vector)
● Optional built in C2 filter ± 0.05% (closed-loop vector)
● Energy Efficiency Certification (IEC/EN 61800-9-2) Picture of compact type of GD380L Speed fluctuation ± 0.3% (sensorless vector control)
Torque response < 20ms (sensorless vector control)
Running Torque control accuracy 10% (sensorless vector control)
control
Constant torque load:

Model Designation Rules GD380L – 7R5G – 4 – C – C2 Overload capability


150% of rated current: 1 minute
180% of rated current: 10 seconds
① ② ③ ④ ⑤ 200% of rated current: 1 second
For asynchronous motor sensorless vector control: 0.5Hz/150%
Starting torque
Key Sign Description Remark For sensor-included vector control: 0Hz/200%
Used to provide more than 30 fault protection functions against faults such as
Abbreviation ① Product series abbreviation GD380L is short for Goodrive380-LIFT Fault protection
overcurrent, overvoltage, undervoltage, overheating, phase loss and overload
Rated power ② Power range + Load type 7R5—7.5kW Mounting method
G-Constant torque load Wall mounting
temperature
S2: 1PH 220Vac(-15%)~240Vac(+10%) Running environment temperature
-10~50℃. The VFD must be derated if temperature is above 40℃
Voltage degree ③ Voltage degree 2: 3PH 220Vac(-15%)~240Vac(+10%)
4: 3PH 380Vac(-15%)~440Vac(+10%) MTBF 100,000 hours
Others Safety Meet CE
Blank: Book type version
Version ④ Product version abbreviation C: Compact type version Cooling method Forced air cooling
Braking unit Built-in for whole series
Filter configuration Default: Empty
Configuration information ⑤ DC reactor Standard configuration for VFD models ≥18.5kW.
C2: With built-in C2 filter
EMC filter Optional built-in C2 filter can be configured, meeting IEC 61800-3 C2 requirements.
Standard Wiring Diagram
Model Selection Main Circuit Wiring Diagram
Model
Power supply Rated power Rated power Input current Output current Net weight Options
voltage (kW) (Hp) (A) (A) (kg)
GD380L-2R2G-S2-C
GD380L-2R2G-2-C
1-phase 220Vac 2.2
2.2
3
3
24
11
10
10
4.1
3.9
Braking Resistor
3-phase 220Vac
GD380L-004G-2-C 4 5.5 17 16 4
GD380L-004G-4-C 4 5.5 13.5 9.5 4.05 Min.braking Recommended braking Recommended
Model Braking unit
GD380L-5R5G-4-C 3-phase 380Vac 5.5 7.5 19.5 14 4.2 resistance (Ω) resistance (Ω) resistor power (W)
GD380L-7R5G-4-C 7.5 10 25 18.5 4.3 GD380L-2R2G-S2-C 22 66 600
GD380L-2R2G-2-C 22 66 600
GD380L-004G-2-C Embedded 24 34 1200
GD380L-004G-4-C 80 130 1200
Application Scenarios GD380L-5R5G-4-C
GD380L-7R5G-4-C
60
47
65
50
1600
1600

Note:
● Select the resistor resistance and power of braking units based on the data provided by INVT.
● Braking resistors may increase the braking torque of the VFD. Select a braking system depending on the actual working
condition.
● If you need to use external braking units, see the instructions on dynamic braking units to set the braking voltage classes of
braking units. Incorrect voltage classes may affect the normal running of the VFD.
Vertical elevator Escalator Stereo garage Note: T1 and T2 are used for maintenance and testing. A1 and A2 are prohibited from wiring when using T1 and T2.