EAX3 Ultrasonic Level Transmitter_new
EAX3 Ultrasonic Level Transmitter_new
com
FEATURES
2 4~20mA 2 wire output (Fully isolated) with HART
2 IP65 protection casing(Stantard), IP66(Remote) B
2 Transducer material: PP、EPOXY and PVDF D
2 False echo detection
2 Internal temperature compensation.
2 Not affected by liquid temperature, S.G, viscosity
F
H B = Blanking distance
H = Height in silo
MAIN FUNCTIONS
2 Level measurement
2 Object distance measurement
1
APPLICATIONS
1. Water or waste water treatment equipment: 3. Chemicals: paints, carbons, water, crude oil,
pumps, open channels, dams and wells. epoxy resin, lime slurry and wax.
2. Edible-oils, sauces and beverages. 4. Diesel, Petrochemicals, alchohols, solvents etc.
Up to 300M 4~20mA
PC or PLC
PM
Meter
PB/PM
panel meter
Liquids
Recorder
Relay output Hi. Alarm
RS232
RS485
Lo. Alarm
DC24V
2
SPECIFICATIONS(Stantard type)
3
SPECIFICATIONS(Remote type)
Model EAX30400-C
Number of channels 1 or 2
Frequency 10 - 60kHz
Measurement object Liquid and powder
Measurement range 0.3 – 20m
Measurement resolution 1mm
Measurement accuracy +/- 0.25% F.S.
Operation temperature -20 - +70 °C
Display LCD display with backlight
Current output 4-20mA output
Contact output Relay output: 4 points * 2 lines
Signal input/output RS232, RS485 (PROFIBUS (Option))
Power source 100 – 240 VAC +/- 15%10VA
4
INSTALLATION
2-wires (power supplied by panel meter) The ultrasonic transducer is mounted to the flange
of the extension nozzle of the tank. Please refer to
+24V
the instruction below:
Length for dead band:
Dead band has to be 150mm over extension nozzle .
FineTek PB Meter
Dead band needs to be set as 500mm if extension
nozzle is shorter than 500mm.
+24V
GND Extension length:
4~20mA Vin
Iin
Please refer to below table and choose the suitable
Com probe
DC24V
6" 150mm 400mm
Power Supply
8" 200mm 600mm
FineTek PI Meter
F G 12" 300mm 600mm
+24V
Iin
Com
L: Extension nozzle
H: Bin High
4-wire (PLC)
+24V
PLC
+24V
GND
Vin
Iin
Com
5
CAUTION BEFORE INSTALLATION
Keep the transducer perpendicular to the liquid The transducer should not be mounted too close to
surface. the tank wall to avoid interference.
X X
A pipe surrounding the detection path along the Do not mount the device close to the tank wall.
ultrasonic wave from emitting to receiving is
Recommended. Installation can prevent false
signals caused by turbulence and foam when an
agitator is present. When the pipe is installed, a
vent hole is required to balance the pressure
difference between the inside and outside of
the pipe...
Vent hole
X
X
Mount the transducer away from the inlet to avoid
interference with the medium.
6
DIMENSIONS
f93
70
110
40
f56
G2(PF2)
Remoto type
152.7 84
80
236.7 236.7
100
. 2
f4
6-
175.7 70
Transducer: B 1"PT
f7
Wiring
PP
Transducer: C 1"PF
f7
Wiring
PVDF
7
ORDERING INFORMATION
Ordering information 05 06 09 10 11 12 13 14 15 16
EAX 3 99 0 0 -9 9999999
05 06 Model
00: Stantard type
04: Remote type
09 Measuring distance
A: 0.25~7.5m (Stantard type)
B: 0.3~10m (Stantard type)
C: 0.3~20m (Remote type)
10 Transducer
A: PP(Stantard type)
B: Sensor surfuce: Epoxy, Housing: PP (Remote type)
C: PVDF (Remote type)
Connection
11 12 13 14 15 16
Taiwan U.S.
Singapore
Indonesia
Singapore
FineTek Pte Ltd. - Singapore Office
37 Kaki Bukit Place, Level 4 Singapore 416215
TEL: 65-6452-6340
EMAIL: [email protected]
Indonesia
PT. FineTek Automation Indonesia - Indonesia Office
PERGUDANGAN TUNAS BITUNG
JL. Raya Serang KM. 13,8, Blok C3 No. 12&15, Bitung Cikupa, Distributor:
Tangerang 15710
TEL: 62 (021)-2958-1688
EMAIL: [email protected]
08-EAXEP-052322