Walnut Model
Walnut Model
8'-512" 8'-512"
612"
9'-512"
12'-514" 3'-3" BELOW TOP OF GRADE) TYP.
48"
FOUNDATION *REFER TO ENGINEER DETAIL S2
STEP POST ATTACHMENT TO
FOUNDATION WALL (TYP.)
33'-10"
2'-1114"
6'-814" 27'-13 4"
L2 3-2x10 3-2x10
10"
10"
BM4 HEADER
48"
*4-2x6 POST FOUNDATION
STEP
7'-4"
(GLUED & NAILED SEE SPEC SHT. FOR DETAILS)
9'-83 4"
BM6 HEADER
4'-5"x2'-8"
UNFINISHED
13'-53 4"
13'-53 4"
1'-1"
BASMENT
TOENAILS AND FASTEN THE BOTTOM PLATE TO THE BASEMENT SLAB USING 3" LONG 1/4" DIA.
*PROVIDE (2) 20M TOP BARS w/ 1 1/4" CLEAR COVER FROM INSIDE FACE OF WALL, INSTALLED
JUST PAST THE STAIR OPENING. WHERE THE FOUNDATION WALL STEPS DOWN AT THE
THE STUDS. FASTEN EACH FLOOR JOIST TO THE TOP OF THE STUD WALL w/ (2) 3 1/4"
24"
ADGAINST THE FOUNDATION WALL (PROVIDE BLOCKING/SHIMS @ 1/3RD POINTS IF
FOUNDATION
PROVIDE 2-2x6 @ 8" o.c. PROVIDE SOLID BLOCKING @ 48" o.c., MIN. 1/2" GYPSUM
STEEL TOP & BASE PLATES INTERIOR SUPPORT (BOTTOM FLANGE TO REMAIN INTACT.
on a 48"x48"x22" CONC. PAD
5'-0"
FOOTING
*4-2x6
13'-0"
POST
*W10x22 or W12x26 (SINGLE SPAN) *W10x39 or W12x30 (SINGLE SPAN)
BEAM
POCKET
FOUNDATION
STEP MORE THAN 25% OF WALL
BM6 HEADER
BM2
4'-5"x2'-8"
TYP.
2'-6"
BM1
TAPCONS @ 32" o.c.
EXTERIOR FACE.
SD/CO
18'-214"
BATHROOM CONFIRM LOC'N WELL
w/ CONTRACTOR
3'-03 4"
"
-8
UP 14
6'
"x
RISERS
3'-3"
-8
2'
7'-63 4"
12'-2"
9
3'-2"
BM7
55'-0"
55'-0"
POSSIBLE ELECTRICAL
35 8"
PANEL LOC'N
20"x20"x8" CONC.
BATH
BM6
SH5
3'-3"
PAD FOOTING
(TILE)
1'-4"
*4-2x4 POST on a
10'-11"
24"x24"x10" CONC.
8'-2 8"5
2'-5 2" 1
PAD FOOTING
BM5
512"
2'-3"
2x6 LOAD BEARING WALL
w/ 14"x6" STRIP FOOTING
24"
1/2" EDGE DISTANCE TO ALL EDGES OF THE FOUNDATION.
*IF WALL BOTTOM PLATE OVERHANGS FOUNDATION EXCEEDING THE
ALLOWABLE 1/3RD PLATE WIDTH, PROVIDE BUILT UP 2x8 LEDGER TO PROVIDE
DIA. HILTI KWIK BOLT 3 EXPANSION ANCHORS @ 16" o.c. w/ 3 1/2" EMBEDMENT, 4
ADDITIONAL SUPPORT FOR THE BOTTOM PLATE. FASTEN TO FOUNDATION w/ 1/2"
UTILITIES / STORAGE
10"
10"
FOUNDATION
BRICK CHECK
2'-3"
2'-512"
LOC'N OF
FURNACE & 28"x28"x12" CONC.
WATER HEATER PAD FOOTING
HRV
12'-5 4"
10'-714"
3
9'-3"
14'-5 4"
20'-9"
3'-2"
3
PRIOR TO INSTALLATION
10" 8'-8" 6'-3"
RECESS FOUNDATION
POSSIBLE ELECTRICAL
HWT
INSTALLATION FROST PROTECTION
SUIT DOOR
TO FTG.
UNEXCAVATED
10"
20'-11"
20'-11"
2'
w/ 10M HOOKS @ 24" o.c. c/w 11" 5'-6" 9" 20'-0" 9"
"
RECESS FOUNDATION
AS REQUIRED TO
SUIT CONCRETE SLAB
9"
9"
37'-4"
FOUNDATION PLAN - A
0 sq.ft. Scale 3/16"-1'-0"
10" DECOR. COLUMN over *6x6 P.T.
STRUCTURAL POST (TYP.)
*(3)-2x12
*(3)-2x12
COVERED DECK
(P.T. WOOD)
SMOOTH CEILINGS
10'-0"
33'-10"
GIRDER TRUSS - G
6'-8 4" 1
14'-6 4" 3
7'-2" 5'-5"
3'-1"
3'-3"
L2 8'-0"x6'-6" L2 L2
1'-214"
1'-214"
1'-214"
Hd1 HEADER Hd1 HEADER
x8
*(
3'
"
3'
"
*(
-0
-0
3)
-0
-0
4)
-2
8'
8'
-2
"x
"x
-2
3)
"x
"x
*2 JACKS
8'
8'
x8
x8
*(
-0
-0
-0
-0
3'
3'
11'-412"
"
"
*1 KING
31'-9"
1'-012" 1'-012"
GREAT ROOM
6'-83 8"
9'-105 8"
2x8 EXTERIOR
)-2 *(
3)
LL
x6
x6
11'-0"
H
T
12'-113 8"
LEFT WALL - 2-2x6 @ 12" o.c.
BM4
REAR WALL - 2x8 @ 12" o.c. DINING ROOM
13'-914"
PROVIDE 2-2x6 @ 8" o.c. PROVIDE SOLID BLOCKING @ 48" o.c., MIN. 1/2" GYPSUM
*W10x60 (FLUSH)
APPROX. STUD HEIGHT (t/o SUBFLOOR TO
(HARDWOOD)
BOARD ON INTERIOR FACE, MIN. 3/8" SHEATHING or 1" RIGID INSULATION ON
9'-0"
25'-612"
1'-10"
1'-11"
418"
25'-113 8"
x6
*(
4)
-2
-2
DW
4)
BM1 (FLUSH)
x6
*(
3'-6" 5'-63 8" 6'-0"
STONE VENEER ON FIREPLACE
BUMPOUT 512"
117 8" PRE-ENG FLOOR
JOIST @ 16" o.c.
10'-0"
VENT TO
EXT.
117 8" PRE-ENG FLOOR JOIST @ 16" o.c.
NON-COMB.
2x6 LOAD
7'-77 8"
BEARING
EXTERIOR FACE.
WALL
14'-103 8"
SPEC SHT. FOR DETAILS)
FRIDGE
KITCHEN
(GLUED & NAILED SEE
WINE
x6
*(
3)
-2
6'-83 8"
-2
3)
(HARDWOOD) BM6
x6
*(
12'-6 8"
7
2'-6" ZERO THRESHOLD
SHOWER ABOVE
*REFER TO S.B.M. DETAIL
9-1/2" PRE-ENG FLOOR
S1 FOR STEEL BEAM SD/CO
JOIST @ 16" o.c.
CONNECTION
x6
)-2 *2 JACKS *(
3)
* (4 42" HALF WALL *1 KING -2
17'-1012"
x6
1'-012"
DRYWALL ARCHED L1 *2 JACKS
BM6
Hd3 HEADER
4'-73 4"
2'-0"x5'-0"
-8
6'
PANTRY
"x
3'-3"
1
-8
2'
9 UP 16
DB1
(HARDWOOD)
L1
7'-63 4"
RISERS
*(
512"
3)
(2)-2x10
-2
BM2
6'-85 8"
x4
"
55'-0"
55'-0"
-8
6'
4'-75 8"
"x
4'-6" 2'-8"x8'-0"
POWDER
512"
-0
35 8"
3'
5'-0" 1'-812"
2'-11"
"
-0
(TILE) BENCH
"
8'
-0
DN 14 *2 JACKS
3'-3"
"x
8'
-8
"x
Hd2 HEADER
2'
-0
LANDING
BM2
L1
2'
MUDROOM
*(
5'-37 8"
5'-37 8"
2'-6"
4)
*(
512"
4)
-2
(TILE)
4'-0"x1'-0"
20'-1" 812"
-2
x6
(TILE)
x6
2'
-0
"x
"
2'-8"
5 5
3 8" 5 2"1
3 8"
-0
8'
x6
'
x8
-0
"
0"
-1
2'
"
-0
*(3)-2x12 or
3'
512"
6" 6"
512"
SPEC SHT. FOR DETAILS)
512" *2 JACKS
4'-6"
*1 KING
STEPS TO SUIT
DEN ARCHED OPENING TO
10'-43 4"
(HARDWOOD)
-8
-2
(HARDWOOD)
11 8" PRE-ENG FLOOR JOIST @ 16" o.c.
14'-53 4"
12'-43 4"
6'
x6
(2) 2x10
w/ SELF-CLOSER &
"x
BARRERL VAULT
-0
WEATHERSTRIPING
3'
5'-87 8"
FOR PROPER DRAINAGE
SPEC SHT. FOR DETAILS)
6'-3"
35 8"
2% SLOPE TO FRONT
1'-0 2"
1
BM3
13'-13 4"
9'-0"
5'-312"
*(
3'
*(2)-2x12 or 2-1.75"x7.25"
3
3)
-0
1'-012"
)-2
-2
*1 KING
"x
x6
6
-0
8'-3"
2.0E LVL
6'-0"x2'-0"
Hd1 HEADER L1
2'-0"
21'-0"
*2 JACKS
*1 KING
(2) 2x10
4'-8"
ACCESS
12'-412"
(2) 2x10
1'-0"
12" DECOR. COLUMN over 4x4 P.T. SPACE & AROUND AIR DUCTS
STRUCTURAL POST (TYP.) BENEATH HEATED SPACE.
1'-0" 5'-5"
L3
L3
1'-6"
2'-6"
1'-8" 5'-83 8" 8"
*(
-2 G
2)
x6 HT
-2
GIRDER TRUSS - A5 BEDROOM
6x
(HARDWOOD)
*TALL WALL FRAMING: (HARDWOOD)
12'-1012"
12'-1012"
9'-1012"
7'-214"
7'-912"
LEFT WALL - 2-2x6 @ 12" o.c.
REAR WALL - 2x8 @ 12" o.c.
APPROX. STUD HEIGHT (t/o SUBFLOOR TO
17'-318"
u/s TRUSS) = 18'-3"
PROVIDE 2-2x6 @ 8" o.c. PROVIDE SOLID BLOCKING @ 48" o.c., MIN. 1/2" GYPSUM
2'-7"
1'-6"
INTERCONNECTED
OPEN TO
35 8"
35 8"
SMOKE DETECTOR
(2
)1
BELOW WALLMOUNT FAUCET '-6
35 8"
3'-1" 4'-4" "x 6'-43 4"
6 *2 JACKS
2'-0"
2'-0"
'-8
" *1 KING
3 8"
5
3 8"
5
"
-8
6'
"x
-6
4'-0"x4'-0"
*(2)-2x10
2'
ENSUITE
6'-1"
7'-5"
7'-13 8"
3'-13 8"
7'-13 8"
(TILE)
DRYWALL ARCHED
8"x15" DECORATIVE DRYWALL BEAM OPENING
2'
FREESTANDING
-6
TUB FILLER8"
EXTERIOR FACE.
"x
8" 5'-05 8"
6'
LINEN CABINET
-8
"
-8
"
2'-0"
2'-0"
35 8" 35 8" 35 8"
6'
"x
-6
2'-6" 3'-418" 2'-1" 3'-1" 4'-4"
2'
ZERO THRESHOLD
512"
WALLMOUNT FAUCET TILE SHOWER
8'-818"
8"x15" DECORATIVE DRYWALL BEAM
BULKHEAD
3'-5"
42" HALF WALL
3'-112"
35 8"
2'-218"
*1 JACK
35 8"
512"
*5-1.5"x5.5" 2.0E CLOSET 35 8"
LSL FULL HEIGHT
46'-1112"
46'-1112"
5'-93 8"
42" HALF WALL
3"
STUDS
(2
*(
) LEDGE
4)
2'
-2
W D -0
x6
"x
4'-73 4"
6 '-8
*(2)-2x10
WEATHER "
LANDING
3'-3"
2'-4"x5'-0"
1 STRIPPED
9 22"x30" ATTIC 10'-113 8"
8'-93 4"
9'-314"
(HARDWOOD)
ACCESS
2'-10"x6'-8"
35 8"
4'-0"x6'-8"
*(2)-2x10
35 8"
4'-8 2"1
5'-10" LAUNDRY
BEDROOM 2
2'-11"
1'-0" (TILE)
3'-3"
DN 16 (CARPET)
RISERS
HALL
7'-9"
*(
3)
(HARDWOOD)
-2
6'-818"
x6
INTERCONNECTED
BEARING WALL SMOKE DETECTOR
CLOSET CLOSET 5'-1014"
*(
3'-8" SD/CO
3)
"
-2
-8
x4
2'-0"
OPT.
6'
3'-112"
"x
35 8"
-6
DESK
35 8"
2'
(2)-2x10
7'-812" 3'-0" 35 8"
35 8" 8"
2'-4"x5'-0"
22'-0 2"
'-
1
6
"
2'
"x
'-8
714"
INTERCONNECTED
-6
-0
"
6
"x
-8
2'
"x
SMOKE DETECTOR
6'
6'
-6
-8
"x
2'
"
-6
2'
1'-57 8"
-4
2'
LINEN
"x
6 '-8
5
"
35 8"
5
3 8" 5
3 8" 5
3 8" INTERCONNECTED
2'
2'-8" *(3
GIRDER TRUSS - C2
3'-7"
-6
)-2
6'
BEDROOM 4 x4
-8
MAIN
"
3 8"
5
GIRDER TRUSS - C
(CARPET)
w/ TILED WALLS
35 8"
DRYWALL ARCHED
BATH
SKIRTED TUB
10'-3"
BARREL VAULT
5'-5"
(TILE) 1'-1012" *(
10'-318"
3'-014"
BEDROOM 3
2)
13'-314"
-2
x6
*(
3)
3)
35 8"
-2
-2
(2)-2x10
x6
x6
L1 2'-0"x6'-0"
(2)-2x10
2'-0"
4'-07 8"
1'-012"
"
-8
4'-412"
6'
CLOSET
"x
-6
L1 5'-10"x6'-0"
2'
2'-4 2"
1'-012"
1'-012"
37'-4"
R2
7'-0"
'-1
0
3 4
"
4'-114"
3/12
3/12
2'-512"
9'-1112"
P
HI
14'-25 8" 10'-1" 9'-63 8"
HI
P
7/12
RIDGE
RIDGE
10/12
HIP
HI
P
VA
LL
EY
10/12
7/12
GABLE
Y
LLE
VA
RIDGE
RIDGE
RIDGE
RIDGE
EY
RIDGE
LL
7/12
VA
VA
10/12
LLE
Y
IP
RIDGE
H
16/12
16/12
10/12
E
OP
SL
E
SLOP
4/12
FLAT ROOF CONSTRUCTION
SINGLE PLY MEMBRANE
5/8" PLYWOOD SHEATHING
CONTINUOUS WOOD STRAPPING
TO PROVIDE MIN 2" SLOPE
2x8 ROOF JOIST @ 16" o.c.
T&G WOOD SOFFIT (CONTRACTOR TO CONFIRM)
ROOF PLAN
Scale 3/16"-1'-0"
UNPROTECTED OPENING AS PER O.B.C. 9.10.15.4 UNPROTECTED OPENING AS PER O.B.C. 9.10.15.4
MINIMUM DISTANCE - 35'-0" (10.67m) MINIMUM DISTANCE - 33'-0" (10m)
TOTAL AREA OF EXPOSED BUILDING FACE - 271.6 FT² (25.2m²) TOTAL AREA OF EXPOSED BUILDING FACE - 126FT² (11.7m²)
MAX. AREA OF UNPROTECTED OPENINGS (100%) - 271.6FT² (25.2m²) MAX. AREA OF UNPROTECTED OPENINGS (100%) - 126FT² (11.7m²)
TOTAL AREA OF UNPROTECTED OPENINGS (28.4%) - 77 FT² (7.2m²) TOTAL AREA OF UNPROTECTED OPENINGS (27.9%) - 35.1 FT² (3.3m²)
12
12 12
10
16 16 ASPHALT
SHINGLES
7:12 PITCH 12
10
ASPHALT
SHINGLES
10:12 PITCH
U/S CEIL
1012" 1012" 1012" 1012"
2'-0"x6'-0"
8'-1"
2'-4"x5'-0"
2'-4"x5'-0"
2'-4"x5'-0"
2'-4"x5'-0"
5'-10"x6'-0"
[7.93m]
26'-0"
1'-0"
R4'-3 8"
BRICK VENEER
9'-1"
3
12" SQ. COLUMN
8'-9"
7'-53 4"
5'-10"x6'-6"
STONE
VENEER
3'-0"x8'-0"
FC8313
1'-4"
4'-0' (MIN)
GRADE 14" MAX. TREAD WIDTH
914" MIN. TREAD WIDTH
7'-10"
STEPPED FOOTINGS:
- 24" MINIMUM HORIZONTAL
- 6" MAXIMUM VERTICAL IN SANDY SOIL
- 24" MAXIMUM VERTICAL INFIRM SOIL
T/O BSMT FOOTING
NOTE: PROVIDE GUARDS (CONFORMING TO NOTE: WHERE PATIO/TERRACE DOOR
DIVISION B, PART 9.8.8 OF THE 2006 ONTARIO THRESHOLD IS GREATER THAN 2'-0" ABOVE
BUILDING CODE AND SB-7 TYPE GUARDS FOR FINISHED GRADE, PROVIDE SB-7 GUARD OR UNPROTECTED OPENING AS PER O.B.C. 9.10.15.4 BUILDING HEIGHT: COMPLIANCE PACKAGE 'A1'
HOUSING AND SMALL BUILDINGS) AT PORCH PROVIDE BLOCKING TO PREVENT DOOR MINIMUM DISTANCE - 37'-0" (11.3m) (AS PER SB-12 TABLE 3.1.1.2.A O.B.C.)
WHERE DISTANCE FROM PORCH TO GRADE FROM OPENING MORE THAN 4". TOTAL AREA OF EXPOSED BUILDING FACE - 109.3 FT² (10.2m²) FRONT ELEVATION: 7.77m
IS 2'-0" OR GREATER. MAX. AREA OF UNPROTECTED OPENINGS (100%) - 109.3FT² (10.2m²) RIGHT SIDE ELEVATION:7.77m TOTAL AREA OF TOTAL AREA OF
TOTAL AREA OF UNPROTECTED OPENINGS (37.2%) - 40.7 FT² (3.8m²) LEFT SIDE ELEVATION: 7.77m ELEVATION EXPOSED BUILDING PROPOSED WINDOW
REAR ELEVATION: 7.77m FACE / DOOR OPENINGS
FRONT 507 FT² (47m²) 152.8 FT² (14.2m²)
TOTAL AVERAGE BUILDING HEIGHT: 7.77m
FRONT ELEVATION
RIGHT 754.3 FT² (70m²) 40.3 FT² (3.7m²)
REAR 608.5 FT² (56.5m²) 140.3 FT² (13m²)
LEFT 507 FT² (47m²) 39.6 FT² (3.7m²)
Scale 3/16"-1'-0" TOTAL 2376.8 FT² (220.8m²) 373 FT² (34.6m²)
TOTAL % OF WINDOW/DOOR OPENING: 15.7%
ROOF VENTS INSTALLED NOT LESS
THAN 1/300 OF INSULATED AREA
AND AS PER O.B.C.9.19.1
12
10
12
ASPHALT
SHINGLES 7
10:12 PITCH
U/S CEIL
1012" 1012"
VINYL
4'-0"x4'-0"
SIDING
8'-1"
2'-4"x5'-0"
2'-4"x5'-0"
[7.93m]
26'-0"
1'-8"
12
T/O 2ND FLR 4 12
3
U/S CEIL
4'-0"x1'-0"
U/S GARAGE
CEIL
DOWNSPOUT
1012"
2'-0"x5'-0"
8'-7"
BRICK
9'-1"
VENEER
7'-3"
6'-0"x2'-0"
8'-9"
4'-5"x2'-8"
4'-5"x2'-8"
GRADE
2'-0"
2'-0"
7'-10"
CLEAR COVER
4'-0" MIN.
T/O BSMT FOOTING
1'-4"
9'-0"
UNPROTECTED OPENING AS PER O.B.C. 9.10.15.4
RIGHT ELEVATION MINIMUM DISTANCE - 6'-6" (2.0m)
TOTAL AREA OF EXPOSED BUILDING FACE - 754.3 FT² (70m²)
MAX. AREA OF UNPROTECTED OPENINGS (9%) - 67.9 FT² (6.3m²)
TOTAL AREA OF UNPROTECTED OPENINGS (5.9%) - 44.9 FT² (4.2m²)
Scale 3/16"-1'-0"
12
10
12
10
12
16
ASPHALT ASPHALT
SHINGLES SHINGLES
7:12 PITCH 7:12 PITCH
U/S CEIL
1012" L321"x321"x41" L321"x321"x41" L321"x321"x41" L321"x321"x41" L4"x321"x41"
BRICK
8'-1"
VENEER
2'-4"x5'-0"
2'-4"x5'-0"
2'-4"x5'-0"
2'-4"x5'-0"
6'-8"
8'-0"x6'-6"
[7.77m]
25'-6"
12 12
T/O 2ND FLR 3 3
8'-0"x2'-8"
3"
16'-10"
U/S CEIL
L4"x321"x41" L4"x321"x41"
BRICK
9'-1"
VENEER
8'-0"x6'-6"
METAL HANDRAIL w/ GLASS
INSERTS
T/O MAIN FLR
CONC. SILL
T/O FOUNDATION WALL L4"x321"x41"
GRADE
8'-0"x4'-0"
4'-0"
7'-10"
METAL HANDRAIL w/
METAL SPINDLES
T/O BSMT FOOTING
CLEAR COVER
4'-0" MIN.
4'-0"
1'-4"
REAR ELEVATION UNPROTECTED OPENING AS PER O.B.C. 9.10.15.4
MINIMUM DISTANCE - 27'-0" (8.2m)
TOTAL AREA OF EXPOSED BUILDING FACE - 608.5 FT² (56.53m²)
MAX. AREA OF UNPROTECTED OPENINGS (56%) - 340.8FT² (31.7m²)
Scale 3/16"-1'-0" TOTAL AREA OF UNPROTECTED OPENINGS (23%) - 140.3 FT² (13m²)
12
10
12
7
ASPHALT
SHINGLES
10:12 PITCH
12
7
ASPHALT
SHINGLES
16:12 PITCH
U/S CEIL
1012"
FLAT ROOF CONSTRUCTION
4'-0"x6'-8"
VINYL SINGLE PLY MEMBRANE
SIDING 5/8" PLYWOOD SHEATHING
8'-1"
7'-0"
TO PROVIDE MIN 2" SLOPE
2x6 ROOF JOIST @ 16" o.c.
T&G WOOD SOFFIT (CONTRACTOR TO CONFIRM)
[7.77m]
25'-6"
5'-418"
1'-0"
E.I.F.S. FRIEZE
BOARD
APPROX. LANDING
LOCATION
"
'-218
BRICK
12" SQ.
R2
9'-1"
VENEER
COLUMN
7'-53 4"
3'-0"x6'-8" TERRACE DOOR
T/O MAIN FLR
8'-8"
T/O FOUNDATION WALL
GRADE
2'-0"
DOWNSPOUT
INTERGRATED
INTO COLUMN
2'-0"
2'-0"
7'-10"
APPROX. LANDING
LOCATION
T/O BSMT FOOTING
CLEAR COVER
4'-0" MIN.
1'-4"
13'-0"
1'-4"
18'-0"
UNPROTECTED OPENING AS PER O.B.C. 9.10.15.4
MINIMUM DISTANCE - 6'-6" (2.0m)
LEFT ELEVATION TOTAL AREA OF EXPOSED BUILDING FACE - 507 FT² (47m²)
MAX. AREA OF UNPROTECTED OPENINGS (10%) - 50.7 FT² (4.7m²)
TOTAL AREA OF UNPROTECTED OPENINGS (7.8%) - 39.6 FT² (3.7m²)
Scale 3/16"-1'-0"
12
10
12
16
NOTE:
FRAMING SHOWN FOR REFERENCE
PURPOSES ONLY. CONTRACTOR TO
COODINATE w/ SHOP DRAWINGS &
FLOOR PLANS.
U/S CEIL
1012"
TYPICAL EXTERIOR WALL
2x4 METAL STUDS FOR SIDING AS SPECIFIED (9.27 OF O.B.C.)
INTERIOR NON-LOADING AIR BARRIER
BEARING WALLS ONLY R-10 RIGID INSULATION
2X6 WD. STUDS @16" O.C.
R-22 FIBERGLAS BATT INSULATION
8'-1"
U/S CEIL
TYPICAL EXTERIOR WALL
4" BRICK (BARRIERS 9.20.9.5 OF O.B.C.)
(MASONRY FLASHING 9.20.13 OF O.B.C.)
1" AIR SPACE MINIMUM
AIR BARRIER
11" TREADS R-10 RIGID INSULATION
16 EQUAL RISERS GREAT KITCHEN w/ JOINTS LAPPED, TAPED OR CAULKED
9'-1"
TO BE AIR BARRIER
ROOM / DINING 2X6 WD. STUDS @ 16" O.C.
R-22 FIBERGLAS BATT INSULATION
6 MIL. POLY VAPOUR BARRIER
3/4" OSB SUBFLOOR 1/2" DRYWALL.
(GLUED AND SCREWED)
117 8" PRE-ENG. FLOOR
JOIST @ 16" o/c
(CONTINUOUS)
T/O MAIN FLR
T/O FOUNDATION WALL
GRADE
TYPICAL BASEMENT WALL
R10 CONTINUOUS INSULATION
11" TREADS
2x6 WOOD STUD w/ R22 BATT INSULATION
14 EQUAL RISERS
10" CONCRETE FOUNDATION (20MPa)
UNFINISHED DAMPPROOFING
7'-10"
AIR-VAPOUR BARRIER
TO BE CONTINUOUS
ABOVE INTERIOR
PARTITIONS
SIDING AS SPECIFIED (9.27 OF O.B.C.)
AIR BARRIER
8'-1"
3 1/2"
5 1/2"
HEADROOM BELOW ALL 2x6 WOOD STUD WALL @ 16" o.c. w/ R22 BATT
BEAM & DUCTWORK INSULATION FULL HEIGHT
2"
30"-36"
32" 14"
MEMOIRS
K-722
BATH
TYPICAL SECOND STOREY WINDOW HEADER TYPICAL SECOND STOREY WINDOW SILL TYPICAL EXTERIOR WALL PENETRATION
APPROVED AIR
BARRIER WRAP
GYPSUM BOARD CAULK AND SECURE THE 6mil POLY
VAPOUR BARRIER AT BASE, SIDES
POLYETHELENE SURROUND SEAL PENETRATIONS 6mil. POLY AND CORNERS OF WALL
RECOMMEND STRAPPING TO
ELECTRICAL WIRE CAULK ALL SIDES OF 6mil SCURE POLY WHEN
POLY TO FRAMING EXPANDING FOAM DRYWLAL NOT INSTALLED
WINDOW OR INSULATION
INSULATED TYPICAL POTLIGHT FOR DOOR FRAME
INSULATED CEILING 6mil POLY VAPOUR
ATTIC SPACE
BARRIER
AIR/VAPOUR BARRIER SEALED TO
SURROUNDING FLANGE/SUPPORT
SEAL 6mil POLY VAPOUR BARRIER TO
(TYVEK) HOUSE WRAP AIR BARRIER
GYPSUM BOARD CEILING
TYPICAL CEILING LIGHT PENETRATION TYPICAL WINDOW OR DOOR FRAME SEAL AIR BARRIER MATERIALS AT BOTTOM PLATE
BEHIND TUB/SHOWER
TYPICAL FLOOR TRANSITION BELT TYPICAL WINDOW OR DOOR FRAME ELECTRICAL PANELS
2. IF THE AIR BARRIER IS LOCATED ON EXTERIOR, SEAL GAPS BETWEEN RIGID INSULATION AND
DOOR OR WINDOW FRAMES. RIGID INSULATION IS TO BE CAULKED TO THE TOP AND BOTTOM
PLATES. TYPICAL EXTERIOR WALL TO FOUNDATION TYPICAL EXTERIOR ABOVE GARAGE
NOTE: PETROLEUM BASED TAR PRODUCTS ARE NOT TO COME IN CONTACT WITH RIGID FOAM
SEATHING.
3. BETLS AT FOUNDATION AND BRICK CANILEVERS ARE TO BE WRAPPED WITH FLEXIBLE AIR
BARRIER MATERAIL AND SEALED TO THE INTERIOR VAPOUR BARRIER, AND FOUNDATION WALL.
DIV. B-PT. 9 9.25.3.3.(6) & (8)
4. WALLS ABUTTING ATTIC SPACE AND AN INTERIOR SPACE ARE TO BE BLOCKED SO THE AIR
BARRIER CAN BE SEALED ALONG THE BLOCKING WITH AN APPROVED SEALANT. DIV. B-PT. 9,
9.25.3.3.(9)
5. ALL PENETRATIONS THROUGH THE WALL OR CEILING AIR BARRIER ARE TO BE TAPED OR
CAULKED. ALL BUTT JOINTS IN PANEL TYPE AIR BARRIERS ARE TO BE TAPED. DIV. B-PT 9,
9.25.3.3(9) HEATED SPACE
10. CLEANOUT COVERS TO BE SEALED, (WEATHER STRIPPED). DIV. B-PT. 9, 9.25.3.1(2) HEATED SPACE UNHEATED SPACE
11. AIR BARRIER TO BE CONTINUOUS THROUGHOUT ENTIRE BASEMENT. DIV. B-PT. 9, 9.25.3.1(2)
SEAL AIR BARRIER AT
BLOCKING OR TAPE TO
12. CAULKING IS REQUIRED AT PERIMETER OF FOUNDATION WALL/FLOOR JOINT AND ALL PIPE AND UNDERSIDE OF LOWER BLOCKING
POST PENETRATIONS. DIV. B-PT. 9, 9.25.3.3(15) CEILING
13. MAINTAIN AIR BARRIER BETWEEN COLD ROOM AND BASEMENT. DIV. B-PT. 9, 9.25.3.1(1)
TYPICAL INTERIOR GARAGE WALL TYPICAL OFFSET CEIILNGS
14. AIR BARRIER IS A SEPARATE INSPECTION WHICH MUST BE CALLED PRIOR TO ANY EXTERIOR
FINISH (BRICK, SIDING) BEING INSTALLED. BUILDER IS RESPONSIBLE TO ENSURE AIR BARRIER
DETAILS ARE IN PLACE WHEN INSPECTION CALLED. DIV. C-PT. 1, 1.3.5.1(e.1)
GENERAL NOTES BASEMENT SLAB GABLE END WALL CONSTRUCTION DOOR SCHEDULE
All construction to comply with requirements of the Ontario Building Code.
· FRAME CONSTRUCTION
·
FOOTINGS (SUPPORTING EXTERIOR WALL) ·
·
· ·
· ·
· ·
·
· ·
· · BRICK VENEER CONSTRUCTION
· ·
·
· ·
· ·
·
·
·
·
·
FOUNDATION WALL
·
·
·
GARAGE WALL CONSTRUCTION WINDOWS
CHIMNEY
· ·
·
·
· ·
·
BRICK OR STONE VENEER 2" x 6" CONST. ·
·
· ·
· ·
· ·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
· LINTEL SCHEDULE FOR MASONARY VENEERS
as per 9.20.5.2B 2012 OBC min. 6" bearing
BRICK STONE
FRAME WALL 2" X 6" CONSTRUCTION
89mm X 89mm X 6.4mm 2.47m 2.30m
102mm X 89mm X 6.4mm 2.66m 2.48m
·
PORCH SLAB CONSTRUCTION 127mm X 89mm X 7.9mm 3.31m 3.08m
· 127mm X 89mm X 11mm 3.48m 3.24m
·
· 127mm X 89mm X 13mm 3.59m 3.33m
· 152mm X 89mm X 11mm 3.82m 3.54m
· GARAGE SLAB 152mm X 89mm X 13mm 4.07m 3.77m
· ·
·
· 152mm X 102mm X 13mm 4.12m 3.82m
178mm X 102mm X 11mm 4.30m 3.99m
· ·
· 178mm X 102mm X 13mm 4.59m 4.25m
·
· ·
·
· ·
·
·
FRAME CONSTRUCTION
·
· ·
·
BEARING PARTITIONS
·
·
·
·
·
· STAIRS / EXTERIOR STAIRS
·
·
ROOF CONSTRUCTION
·
·
·
·
·
·
SOIL GAS CONTROL
·
·
·
·
· ·
·
· ·
·
·
·
·
WEEPING TILE
·
·
·