SunSpecModbus-TI-en-11
SunSpecModbus-TI-en-11
SUNSPEC MODBUS
SUNNY BOY / SUNNY TRIPOWER / SUNNY HIGHPOWER
Table of Contents
1 Validity.......................................................................................................................................... 3
2 Safety ............................................................................................................................................ 4
2.1 Intended Use.................................................................................................................................................... 4
2.2 IMPORTANT SAFETY INSTRUCTIONS ......................................................................................................... 4
3 Activating the SunSpec Modbus ................................................................................................. 6
4 SunSpec Profile ............................................................................................................................ 7
5 Supported Information Models .................................................................................................. 9
6 Not Supported Information Models........................................................................................... 10
7 Improvements in SunSpec Profile 1.1 and 2.0 .......................................................................... 11
1 Validity
This document is valid for:
Products from firmware version
PV inverter SB3.0-1AV-41 / SB3.6-1AV-41 / SB4.0-1AV-41 / 4.00.23.R
SB5.0-1AV-41 / SB6.0-1AV-41 (Sunny Boy 3.0 / 3.6 /
4.0 / 5.0 / 6.0)
STP3.0-3AV-40 / STP4.0-3AV-40 / STP5.0-3AV-40 / 4.00.02.R
STP6.0-3AV-40 (Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0)
STP8.0-3AV-40 / STP10.0-3AV-40 (Sunny Tripower 4.00.02.R
8.0 / 10.0)
STP 50-41 / STP 33-US-41 / STP 50-US-41 / STP 62- 3.14.##.R
US-41 (Sunny Tripower CORE1)
SHP 100-21 / SHP 150-21 / SHP 172-21/ SHP 125- 4.##.##.R
US-21 / SHP 150-US-21 / SHP 165-US-21 / SHP 172-
US-21 / SHP FLEX-US-21 / SHP 100-JP-21 / SHP 143-
JP-21 (Sunny Highpower PEAK3)
2 Safety
2.1 Intended Use
The Modbus interface of the SMA products is designed for industrial use and has the following tasks:
• Remote control of grid management services
• Remote-controlled querying of measured values
• Remote-controlled changing of parameters
• Interface for direct marketing
The Modbus interface can only be used via the Modbus TCP protocol.
All components must remain within their permitted operating ranges and their installation requirements at all times.
Use SMA products only in accordance with the information provided in the enclosed documentation and with the
locally applicable laws, regulations, standards and directives. Any other application may cause personal injury or
property damage.
Any use of the product other than that described in the Intended Use section does not qualify as appropriate.
The enclosed documentation is an integral part of this product. Keep the documentation in a convenient, dry place for
future reference and observe all instructions contained therein.
This document does not replace any regional, state, provincial, federal or national laws, regulations or standards that
apply to the installation, electrical safety and use of the product. SMA Solar Technology AG assumes no responsibility
for the compliance or non-compliance with such laws or codes in connection with the installation of the product.
NOTICE
Damage of SMA products due to cyclical changing of parameters
The writable Modbus registers (RW) of the SMA products are intended for long-term storage of device settings.
Cyclical changing of these parameters leads to destruction of the flash memory of the SMA products.
The following parameters are excluded. The parameters may be changed cyclically.
• Information model 123:
– Conn
– WMaxLimPct
– OutPFSet
– VArWMaxPct
– VArMaxPct
• Information model 704:
– WMaxLimPct
– WSet
– WSetPct
– VarSetPct
– PF + Ext (WInj, Power factor & excitation setpoint when injecting active power)
– PF + Ext (WAbs, Power factor & excitation setpoint when absorbing active power)
Figure 1: Activation via the installation assistant on the inverter's user interface
4 SunSpec Profile
There are 3 SunSpec Modbus profiles:
• SunSpec profile 2.0
• SunSpec profile 1.1
• SunSpec profile 1.0
The SunSpec profile is automatically selected by setting a country data set when commissioning the product.
For systems with inverters for which a country data set is selected that is based on the SMA Grid Guard 10, this option
does not exist.