Datasheet AMRAN POK
Datasheet AMRAN POK
2-4-6-8-12 CONTACTS
S ERIES
A P P L I C AT I O N S
OVERVIEW
POK • Compact plug-in monostables instantaneous relays
• Solid and rugged construction for heavy or intensive duty
• Considerable long-life
BIP OK • Independent and self-cleaning contacts
• Separate arc breaking chambers
• Magnetic arc blow-out standard
• Excellent shock and vibration resistance
• Option for use in geothermal sites available
• Also available in current-monitoring version
TR I P OK • Also available in PCB-mount version
• Wide variety of configurations and customizations
• Retaining clip for secure locking of relay on socket
DESCRIPTION
The POK range consists of a 2-contact relay module that can In particular, the considerable resistance to shocks and
be constructively assembled to reach relays with up to 12 vibrations allows it to be used on rolling stock.
contacts SPDT.
The peculiarities of this relay model are:
Designed in 1972 immediately after the OK relays, the POK - the absence of connection braids and soldering on the
relay whose name originates in “Petite OK”, was born as a contact terminals. The socket connection terminals are the
series of high-performance relays with small dimensions. direct extension of the contacts.
This series totally represents the core values of the company - the absence of return springs inside the mechanism.
and the constructive objectives that it sets itself: to create - the movement, which is made entirely of metallic material, is
electromechanical components that are able to achieve the not subject to thermal aging typical of plastic materials.
maximum reliability, and that are suitable for use in severe - the remarkable resistance to shocks and vibrations, as well
operating environments, covering roles with the highest as resistance to high operating temperatures and high thermal
responsibility for intervention. shocks.
The contacts are independent and physically divided between
The choice of materials is also very accurate in the various
them, allowing a better interruption of the electric arc.
options available. For example, it is possible to choose
They are equipped with a magnetic blower that guarantees
between different gold-plating treatments of the contacts,
particular efficiency in opening direct current loads.
which together with the tropicalization of the coil, make the
POK relay usable also in geothermal production plants and
in all those environments where strong corrosive gases are STA N DA R D C O M P L I A N C E
present. EN 61810-1
EN 60077
The POK relay, despite its size, guarantees remarkable EN 61810-2
EN 50155
mechanical and electrical performance that make it ideal for EN 61810-7
EN 61373
EN 60695-2-10
use in control and signalling functions in power generation EN 45545-2
EN 61000
plants, electrical substations, in railway transport or in ASTM E162, E662
EN 60529
industries with production processes.
MODELS NUMBER OF CONTACTS NOMINAL CURRENT ROLLING STOCK APPLICATION
POK 2 5A •
POKS 2 10 A •
BIPOK 4 5A •
BIPOKS 4 10 A •
TRIPOK 6 5A •
TRIPOKS 6 10 A •
QUADRIPOKS 8 10 A •
ESAPOKS 12 10 A
COIL DATA POK - POKS BIPOK - BIPOKS TRIPOK - TRIPOKS QUADRIPOKS ESAPOKS
Nominal voltages Un (1)
DC: 12-24-36-48-72-96-110-125-132-144-220 AC: 12-24-48-110-127-220-230
Max. consumption at Un (DC/AC) 2.5W / 3.5 VA 3W / 4 VA 3.5W / 5.5 VA 6W / 8 VA 7W / 11 VA
Operating range (1)
DC: 80…115% Un AC: 85…110% Un
Rolling stock version (2) (3)
DC: 70…125% Un
Type of duty Continuous
Drop-out voltage (4)
DC: > 5% Un AC: > 15% Un
3. For operating ranges different to that specified by EN60077, refer to table “Railways, rolling stock - Special operating ranges”.
4. Limit value for supply voltage, expressed as % of the nominal value, beneath which the relay is certainly de-energized.
CONTACT DATA POK - POKS BIPOK - BIPOKS TRIPOK - TRIPOKS QUADRIPOKS ESAPOKS
Number and type 2 SPDT, Form C 4 SPDT, Form C 6 SPDT, Form C 8 SPDT, Form C 12 SPDT, Form C
POK - BIPOK - TRIPOK POKS - BIPOKS - TRIPOKS - QUADRIPOKS - ESAPOKS
Current Nominal (1) 5A 10 A
Maximum peak (1 min) (2) 10 A 20 A
Maximum pulse (10 ms) (2) 100 A 150 A
Example of electrical life expectancy (3) 0.2 A – 110 Vdc – L/R 40 ms : 105 operations 0.5 A – 110 Vdc – L/R 40 ms : 105 operations
1800 operations/h 0.7 A – 110 Vdc – L/R 0 ms : 105 operations 1 A – 110 Vdc – L/R 0 ms : 105 operations
Minimum load (4) Standard contacts 500 mW (20V, 20 mA)
Gold-plated contact P4GEO (5) 100 mW (10V, 5 mA)
Gold-plated contact P8 (5) 50 mW (5V, 5 mA)
Maximum breaking voltage 250 Vdc / 350 Vac
Contact material AgCu Ag / AgCu
Operating time at Un (ms) (6) (7) DC – AC
Pick-up (NO contact closing) ≤ 20 - ≤ 20 ≤ 25 - ≤ 25 ≤ 25 - ≤ 25 ≤ 25 - ≤ 25 ≤ 25 - ≤ 25
Drop-out (NC contact closing) ≤ 15 - ≤ 20 ≤ 20 - ≤ 40 ≤ 20 - ≤ 45 ≤ 20 - ≤ 40 ≤ 20 - ≤ 45
2. The max. peak and pulse currents are those currents that can be handled, for a specified time, by the contact. They do not refer to steady or interrupted currents.
4. Values referred to a new product, measured in laboratory. The ability to maintain this performance over the time depends on the environmental conditions and the contact’ frequency use.
The use of gold plated contacts is recommended in the case of very low loads.
a. Plating material: P4GEO: gold-nickel alloy (>6µ) P8: gold-cobalt alloy (>5µ), knurled contact
b. When the gold-plated contact is subject to heavy loads, it will be degraded on the surface. In this case, the characteristics of the standard contact should be taken into consideration.
6. Unless specified otherwise, the operating time signifies until stabilization of the contact (including bounces).
7. Addition of a flyback diode connected in parallel with the coil (DC version only) causes an increase in operating time when the relay drops out.
P a ge 2 / 8
INSULATION
Insulation resistance (at 500Vdc)
between electrically independent circuits and between these circuits and ground > 1,000 MΩ
between open contact parts > 1,000 MΩ
Withstand voltage at industrial frequency
between electrically independent circuits and between these circuits and ground 2 kV (1 min) - 2.2 kV (1 s)
between open contact parts 1 kV (1 min) - 1.1 kV (1 s)
between adjacent contacts 2.5 kV (1 min) - 3 kV (1 s)
Impulse withstand (1.2/50μs - 0.5J)
between electrically independent circuits and ground 5 kV
between open contact parts 3 kV
MECHANICAL SPECIFICATIONS
Mechanical life expectancy DC: 20 x 106 - AC: 10 x 106 operations
Maximum switching rate Mechanical 3,600 operations / hour
Degree of protection (with relay mounted) IP40
POK - POKS BIPOK - BIPOKS TRIPOK - TRIPOKS QUADRIPOKS ESAPOKS
Dimensions (mm) (1)
20 x 50 x 45 40 x 50 x 45 60 x 50 x 45 80 x 61 x 45 120 x 50 x 45
Weight (g) ~ 90 ~ 170 ~ 250 ~ 340 ~ 520
ENVIRONMENTAL SPECIFICATIONS
Unless otherwise specified, the products are designed and manufactured according to the requirements of the above-mentioned European and International standards.
In accordance with EN 61810-1, all technical data are referred to ambient temperature of 23°C, atmospheric pressure of 96kPa and 50% humidity.
EN 60077 Electric equipment for rolling stock - General service conditions and general rules
EN 50155 Electronic equipment used on rolling stock
EN 61373 Shock and vibration tests, Cat 1, Class B
EN 45545-2 Fire behaviour, Cat E10, Requirement R26, V0
ASTM E162, E662 Fire behaviour
P ag e 3 / 8
RAILWAYS, ROLLING STOCK - SPECIAL OPERATING RANGES FOR POK(S) - BIPOK(S) RELAYS (1)
Nominal voltage Minimum pick-up voltage Maximum operating voltage Order symbol (1)
24 Vdc 18 33 Z01
24 Vdc 16 32 Z02
24 Vdc 19 30 Z04
36 Vdc 28 46 Z01
72 Vdc 55 96 Z02
(1) To order the relay with the special operating range, indicate the “Z0x” symbol in the “Keying position” field of the ordering scheme.
The special range may be subject to operating specifications different from standard specifications. Please contact us for further information.
CONFIGURATION - OPTIONS
Tropicalization of the coil with epoxy resin for use with 95% RH (@ T 50 °C). This treatment also protects the coil
P2 against corrosion which could occur by combination of the humidity with certain chemical agents, such as those
found in acid atmospheres (typical of geothermal power stations) or saline atmospheres.
Gold plating of contacts with gold-nickel alloy, thickness ≥ 6μ. This treatment ensures long-term capacity of the
P4GEO contact to conduct lower currents in harsh ambient conditions such as acid atmospheres (typical of geothermal
power stations) or saline atmospheres.
P6GEO P4GEO type gold-plating, but applied to contacts, contact terminals and output terminals + P2 coil tropicalization.
Gold plating of contacts with gold-cobalt alloy, thickness ≥ 5μ, knurled fixed contact. This finish allows further
P8
improvement of the performance provided by gold-plated contact, compared to P4GEO treatment.
LED LED indicator showing presence of power supply, wired in parallel with the coil.
Polarized component connected in parallel with the coil (type 1N4007 or BYW56 for rolling stock version) designed
FLYBACK DIODE
to suppress overvoltages generated by the coil when de-energized.
Non-polarized component connected in parallel with the coil, designed to suppress overvoltages higher than the
VARISTOR
clamping voltage, generated by the coil when de-energized.
Non-polarized component connected in parallel with the coil. Behaviour is similar to that of a varistor, with faster
TRANSIL
operating times.
LOW TEMPERATURE Minimum operating temperature -50°C, only for rolling stock version (option “L”).
Pa ge 4 / 8
ORDERING SCHEME
TPOKS E 3 0 A 230
TPOKSE30-A230 - TRIPOKS relay, ENERGY series, nominal voltage 230 Vac, equipped with varistor
Example
BPOKS R 5 8 C 024
BPOKSR58-C024 - BIPOKS relay, ROLLING STOCK series, nominal voltage 24 Vdc, equipped with diode, LED, with P8 finish (gold-plated contacts)
POK R 1 0 C 110 L
POKR10 - C110 L - POK relay, rolling stock series, nominal voltage 110 Vdc with option “low temperature”
Suitable on energy production, transport and distribution plants, railways fixed equipment, petrolchemical and heavy industry.
R = RAILWAYS, ROLLING STOCK: Application on board rolling stock (rail-tram-trolley vehicles). Electrical characteristics according to EN60077.
RAILWAYS, FIXED EQUIPMENT: Approved and conforming relays and products to RFI (FS Group) specification no. RFI DPRIM STF IFS TE 143 A
For the list of RFI approved and conforming products, consult dedicated catalogue “RAILWAY SERIES – RFI APPROVED”.
For the list of ENEL approved and conforming products, consult the dedicated catalogue “STATIONS SERIES – LV15-LV16-LV20”.
(3) Optional value. PCB-mount version available for POK - POKS - BIPOK - BIPOKS only. Multiple selection possible (e.g. CS - L).
The positive mechanical keying is applied according to the manufacturer’s model (not available for PCB-mount versions).
WIRING DIAGRAM +
Q UA DR I PO K S
ESA PO K S
P ag e 5 / 8
DIMENSIONS
20 40 60 8 50
45
45
45
P OK - P OK S BIP OK - BIP O K S T R I PO K - T R I PO K S
80 8 61 120 8 50
45
45
QUAD RIP OK S ESA PO K S
20 4 54 10
40 4 54 10 10 10
φ 1,8 φ 1,8
50 10 50 10
45
45
10 10
4 4
4 10 4 10
10 10 10 10
DC AC
Current Current
Some examples of electrical life expectancy 220Vdc – 0.2 A – L/R = 10 ms : 105 operations
110Vdc – 0.5 A – L/R = 10 ms : 5 x 105 operations 440Vac - 0.2 A – Resistive : 5 x 105 operations
Pa ge 6 / 8
SOCKETS POK - POKS BIPOK - BIPOKS TRIPOK - TRIPOKS QUADRIPOKS ESAPOKS
Number of terminals 8 16 24 32 48
For wall or rail mounting
Spring clamp, wall or DIN H35 rail mounting PAIR080 PAIR160 PAIR240 PAIR320 PAIR480
Screw, wall or DIN H35 rail mounting 50IP20-I DIN 48BIP20-I DIN 78BIP20-I DIN 96IP20-I DIN 156IP20-I DIN
Screw, wall mounting 50L 48BL 78BL 96BL 156BL
For flush mounting
Spring clamp PRIR080 PRIR160 PRIR240 PRIR320 PRIR480
Double faston (4.8 x 0.8 mm) ADF1 ADF2 ADF3 ADF4 ADF6
Screw 53IL 43IL 73IL - -
For mounting on PCB
65 (1)
65 - - -
RETAINING CLIPS (correspondence with sockets) POK - POKS BIPOK - BIPOKS TRIPOK - TRIPOKS QUADRIPOKS ESAPOKS
Number of clips per relay 1 1 (1)
2 2 2
SOCKET MODEL CLIP MODEL
For wall or rail mounting
PAIR080, PAIR160, PAIR240, PAIR320, PAIR480 RPB48 RPB48 RPB48 RQ48 RPB48
50IP20-I DIN, 48BIP20-I DIN, 78BIP20-I DIN,
RPB48 RPB48 RPB48 RQ48 RPB48
96IP20-I DIN, 56IP20-I DIN
50L, 48BL, 78BL, 96BL, 156BL RPB48 RPB48 RPB48 RQ48 RPB48
For flush mounting
PRIR080, PRIR160, PRIR240, PRIR320, PRIR480 RPB48 RPB48 RPB48 RQ48 RPB48
ADF1, ADF2, ADF3, ADF4, ADF6 RPB48 RPB48 RPB48 RQ48 RPB48
ADF, 53IL, 43IL, 73IL (2) RPB43 RPB43 RPB43 - -
For mounting on PCB
65 RPB43 RPB43 - - -
(2) Insert the clip before fastening the socket on the panel.
P ag e 7 / 8
Operation
Before use: if relay is not used, for example after long storage periods, contact resistance may increase due to a natural and slight oxidation
or polluting deposits.
In order to restore the optimal conductivity and for standard contacts (NOT gold plated) it is recommended to switch several time a load of at
least 110Vdc - 100mA or 24Vdc - 500mA. The contacts will be "cleaned" thanks to the electric arc generated during the current interruption and
the mechanical self-cleaning action.
The common contact rubs against the fixed poles (NO and NC contacts) both when opening and when closing, which ensures a self-cleaning action.
An increase in contacts' resistance, in most cases, does not represent a problem. Many factors contribute to the correct use of contact and
consequently to the relay' long-term reliability:
• Load: the current switching generates an electric arc with cleaning effects. For proper electrical cleaning and performance keeping
we recommend:
o Standard contacts: Minimum current = 20mA
o Gold plated contacts: Minimum current = 10mA
• Operating frequency: relays are components that can operate with a wide range of switching frequency. High frequency operation also allows
a continuous cleaning effect by "sliding" (mechanical cleaning). In case of low frequency operation (for example few time a day), we advise:
o Use of contact with currents twice compared to those indicated.
o For currents lower than 10mA, use gold plated contacts and connect 2 contacts in parallel, in order to reduce the equivalent contact
resistance
• Pollution: the presence of pollution can cause impurities on contact surface. Electric charges attract organic molecules and impurities
that are deposited on the contact surface. Electrical and mechanical cleaning, respectively, burn and remove such impurities. In pollution
presence, the minimum recommended currents must be respected. In extreme cases, provide double the cleaning current.
Condensation is possible inside the relay when energized and the outside ambient temperature is cold; this is quite normal and does not affect
the operation of the relay. Plastic materials of relay do not possess hygroscopic properties.
Maintenance
No maintenance is required.
In case of normal relay wear (reaching the end of electrical or mechanical life), the relay cannot be restored and must be replaced.
To check the component, relay removal must be carried out with slight lateral movements. An “up and down” movement can cause terminals damage.
ST-GB-650 Ed. 05/21 - Non-contractual document - Specifications are to be confirmed at time of ordering and subject to change without notice.
Often the malfunctions are caused by power supply with inverted polarity, by external events or by use with loads exceeding the contact performance.
In case of suspected malfunction, energize relay and observe if mechanical operation of contacts / relay mechanism is performed. Pay attention
to the power supply polarity, if relay is equipped with polarized components (example: diode, led).
• In case of expected operation, clean the contacts (see paragraph "OPERATION") and check if the circuit load ranges within the contact performance.
If necessary, replace with relays with gold contacts. Note: the electrical continuity of contacts must be checked with adequate current.
• If it does not work, we recommend to use a relay of the same model and configuration.
If an investigation by AMRA is required, pull-out the relay from the socket, don't remove the cap, avoid any other manipulation and contact
us. You will be asked for the following data: environmental conditions, power supply, switching frequency, contact load, number of operations
performed.
The fault can be described through the “TECHNICAL SUPPORT" section of the website www.amra-chauvin-arnoux.it.
In any case, the relay cannot be repaired by the user.
Storage
Storage conditions must guarantee the environmental conditions (temperature, humidity and pollution) required for the product conservation,
in order to avoid deterioration.
The product must be stored in an environment sheltered from atmospheric agents and not polluted, with an ambient temperature between -50
and +85°C with max 75% RH. Humidity can reach peaks of 95%. In any case, there must be no condensation. Before use, please read carefully
“OPERATION” section.
A.M.R.A. SpA
Via Sant’Ambrogio, 23/25 - 20846 Macherio (MB) - Italy
( +39 039.245.75.45 6 +39 039.48.15.61
* [email protected] www.amra-chauvin-arnoux.it