MasterSeal M 800 ®

(formerly known as Conipur M 800)

Spray applied elastomeric polyurethane waterproofing membrane

DESCRIPTION Viscosity @ 23°C Part A >2400mPas


MasterSeal M 800 is a solvent free highly elastic, Part B >2500mPas
two component waterproofing membrane. Due to Ambient temperature range 5 °C to 40 °C
its fast cure speed it can only be applied by
Substrate temperature range 5 °C to 40 °C
special, two component spray equipment.
RECOMMENDED USES Relative humidity max. 85 %

MasterSeal M 800 is intended for use in general Technical data cured material
waterproofing applications such as car park decks, (sprayed film except where stated)
podium decks and cut and cover tunneling.
Shore A 14 Days >70
Using the appropriate primer, MasterSeal M 800 hardness
can be applied to most substrates including
concrete, galvanised steel, aluminium, UPVC, Tensile strength ASTM D412 >8 MPa
glass reinforced polyester etc. Elongation ASTM D412 >350%
FEATURES AND BENEFITS Tear strength ASTM D624 > 16 N/mm
 Fast reacting spray application – Complex The performance data is typical and based upon
details both horizontal and vertical easy to controlled laboratory conditions. Actual
waterproof performance on the job site may vary from these
 Application to vertical surface without runs values based on actual site conditions.
– Installation to walls not problem APPLICATION
 Monolithic – No laps, welds or seams Surface Preparation
 Fully bonded – Moves with the structure The concrete substrates to be coated must be at
 High water vapour permeability – Low risk of least 14 days old, dry and load-bearing, free of
blistering in service laitance as well as substances which impair
 Crack bridging capability- Can cope with adhesion such as oil, grease, rubber skid marks,
cracks that occur after installation paint or other contaminants. Preparation of the
substrate by grit or shot blasting, high-pressure
 Solvent and monomeric isocyanate free – water jetting, grinding or scarifying is necessary for
Increased safety for applicators plain concrete or when the primer has become
 Unaffected by standing water or ground soiled or when the re-coating interval has been
water – Suitable for constant water contact exceeded. Prior to application of the primer the
 Thermoset – Does not soften at elevated bond strength of the concrete substrate must be at
temperatures encountered on a roof least 1.2 MPa (check with an approved pull-off
tester).
 Remains elastic at low temperatures-Tg
approx. -45°C – Suitable for all Asia Pacific The substrate to be coated must be protected
against rising damp by having a damp proof
climates
membrane installed if it is a slab in contact with the
PROPERTIES ground.
MasterSeal M 800 can only be applied by means
Mixing ratio A:B of a suitable two component spray machine. For
by weight 100 : 73 advice on machines, please contact your local
by volume 100 : 70 BASF technical representative.
Density @ 23°C Part A 1.06 g/cm3
Part B 1.10 g/cm3
MasterSeal M 800 ®

(formerly known as Conipur M 800)


MasterSeal M 800 when sprayed results in a application of any wear coat or two part top coat
uniform grey colour which gives the sprayer a (even if the re-coat interval has not been
visual control of the quality of the mixing as exceeded). In the tropics any exposed MasterSeal
machine faults become immediately obvious. This M 800 must be treated as above if left overnight.
can reduce costly clean up time and material For more information about application, please
wastage. Due to the fast reaction it is possible to obtain a copy of the BASF “Application Guide for
rapidly build thicknesses from 1.0 to > 6 mm. MasterSeal Spray Membrane System” from your
Surrounding areas should be protected from local representative.
overspray by masking off with e.g. polyethylene ESTIMATING DATA
sheet. or paper. Care should be taken to prevent
spray mist being carried by wind by erecting MasterSeal M 800 is normally applied at 1.8 – 2.4
suitable barriers. The temperature of the substrate kg/m2. This corresponds to a thickness of approx.
should be min. 3ºC above the dew point prior to 1.8 – 2.4mm. Add for wastages depending on the
application of the membrane. area of application and site conditions.
Primer PACKAGING
Primer has to be cured to a ‘tack-free’ state prior to MasterSeal M 800 is supplied in 210kg drums –
the application of MasterSeal M 800. Use the Part A and 220kg drums – Part B.
following guide to select the appropriate primer:
SHELF LIFE
Substrate Primer
Twelve months if stored in original containers
Concrete Mastertop P 660 under dry conditions at a temperature between 10-
MasterSeal P 2525 30° C. Do not store in direct sunlight for more than
3 days.
PRECAUTIONS
Other substrates Contact your local BASF
Construction Chemicals For the full health and safety hazard information
technical representative and how to safely handle and use this product,
please make sure that you obtain a copy of the
Top Coats and Wear Coats BASF Material Safety Data Sheet (MSDS) from
MasterSeal M 800 does not have sufficient UV our office or our website.
and weather resistance to be used in exposed
applications without protection. A number of top
coats and wear coats are available including
MasterSeal TC 269/268 which can be broadcast
with dry silica sand to provide a hard wearing, non-
slip surface.
Note: if rain falls or dew occurs on the surface of
MasterSeal M 800 then the membrane must be
dried and MasterSeal P 691 applied prior to
the
ID#MasterSeal M800 IN v5.1016
The technical information and application advice given in this BASF Construction Chemicals publication are based
STATEMENT OF on the present state of our best scientific and practical knowledge. As the information herein is of a general
RESPONSIBILITY nature, no assumption can be made as to a product's suitability for a particular use or application and no warranty
as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law.
The user is responsible for checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF Construction Chemicals, are responsible for carrying out procedures appropriate to a specific application.

BASF India Limited


Construction Chemicals Division
Plot.No.12,TTC Area
Thane BelapurRoad,Turbhe
Navi Mumbai - 400705,India
Tel: +91 22 67127600, Fax: +91 22 67917358
E-mail: [email protected] , www.master-builders-solutions.basf.in