Ambient Air Monitoring Systems

ECM systems for ambient air monitoring are usually built into air-conditioned thermally insulated
containers. Monitoring stations can be stationary or mobile.

The usually monitored gaseous pollutants are:

➢ SO2 ➢ H2S ➢ CxHy


➢ NOx ➢ TRS ➢ PAH
➢ O3 ➢ NH3 ➢ HF
➢ CO ➢ VOC

Automated Ambient Air Mercury Analyzer

Mercury analyzer for continuous monitoring with unrivaled accuracy, sensitivity and reliability.

Key features:

• Low detection limit <0.1 ng / m3


• Internal permeation tube for automatic calibration
• Dual-channel gold absorber for continuous sampling
• Low operating costs

www.ecomonitoring.com
Aerosols are monitored in accordance with TSP, PM10, PM2.5 or PM1 regulations.
Simultaneous monitoring and sampling of different fractions.

Certified dual-channel particle monitor combined with a


certified sampler and an 8-channel optical module with
continuous output of individual fractions.

Samplers allow the storage of aerosol samples for later


analysis of heavy metals or other contaminants.

Aethalometer

The Aethalometer TM is an ideal instrument for measuring the content of total or elemental carbon in
airborne dust.
An aethalometer is an instrument that uses continuous sampling and optical analysis technology to
measure carbon concentration in near real time.

OC/EC analyzers

Thermal OC / EC analyzers with laser pyrolysis correction and compatibility with the standard
NIOSH 5040 method.

www.ecomonitoring.com
Ultrafine particle TSI monitor

Continuous monitoring of ultrafine particles (UFP) and air quality monitoring (SMPS).

Features and advantages:

• Designed for continuous operation


• Technology according to CEN / TS 17434
• Fast scan time
• Portable but also stationary
• No radioactive materials

Compact instruments for monitoring PM10, PM2.5 and PM1


airborne dust fractions.

Particle counter allowing to define 16 size channels, with display of the number of particles and
at the same time their mass concentration.

On-line monitoring of heavy metals in dust aerosols

The device works on the principle of XRF and performs on-line analysis of metals contained in
dust aerosols. It is designed for unattended continuous operation in air monitoring stations.

www.ecomonitoring.com
AQM 65

To increase the accuracy and stability of measurement the stations are


equipped with internal air conditioning of the sensor space and heating
of dust components for correct measurement even during foggy and
rainy days. The reliability of the measurement of gaseous components
is ensured by periodic calibration using reference gases from pressure
cylinders.

AQMesh

AQMesh monitoring modules are compact, allowing power from


batteries or solar cells.
Information from the sensors is transmitted over the mobile network to
a central server, where it is interpreted for pollutant concentrations and
made available to customers via the Internet. The reliability of the
measurement is verified by comparison with a reference monitoring
station, where it adjusts the interpretation algorithms in the central
server.

DustTrak

If you are only interested in measuring airborne dust, simplified


versions of stations are available that measure only dust, or dust and
one gaseous component.

Odor
In addition to the individual gaseous components, we often encounter interest in measuring odors.
The human nose is more sensitive to some smelly substances than most devices.
Olfactometers are used to evaluate odorous substances and analytical instruments are also
available for their continuous evaluation.

www.ecomonitoring.com
Vehicle emissions

Air pollution from transport is a significant problem. New analytical instruments allow remote
measurement of pollution from each passing vehicle during normal traffic.

Sampling for laboratory analysis

Reference sampling devices for dust or gaseous


components make it possible to determine
accurately the concentration of pollutants such as
heavy metals, hydrocarbons and other pollutants in
laboratories.

Data systems

Data are collected via mobile networks, evaluated, archived and made available through information
panels or the Internet.

For detailed information on any solutions of your interest we are gladly available on our below
contact:

ECM ECO Monitoring, a.s. Tel.: +421 2 4342 9417


Nevädzová 5, 821 01 Bratislava E-mail: [email protected]
Slovak Republic www.ecomonitoring.com