Input Data
Material Properties :-
Concrete Compressive Strength FC` 40 Mpa
Concrete Compressive Strength Fy 460 Mpa
Section Properties :-
Section Width b 1000 mm Exposure Condition
Section Thickness h 400 mm wc-all 0.00 mm
User Define
Cover To Center Of Closest Tension Bars dc 50 mm wc-all 0.20 mm
Cover To Center Of Tension Bars dcg 50 mm Max Stress Of Tension Steel
Important Note:- As Per ACI350R-01 When The Concrete Cover Exceed 50mm Use Only 50mm Normal Enviromental Exposure-One Way Member
Applied Service Moment :-
Applied Service Moment Ms 114 Kn.m Method 01
Section Reinfocement :- wcr = 11*10^-6*β*Fs*(A*dc)^1/3 Method 01
No Dia Area/mm 2
wcr = 2*(Fs/Es)*β*((dc)^2+(S/2)^2))^0.5
Method 02
Main 7 20 2198
Tension RFT
Extra 0 20 0
Spacing Between Bars S 150 mm