You are on page 1/ 5

© 2023 TVET CDACC

073204T4PLM
PLUMBER LEVEL 4
CON/OS/PL/CR/01/4/A
INSTALL WATER PIPES AND ANCILLARY APPLIANCES
NOV /DEC 2023

TVET CURRICULUM DEVELOPMENT, ASSESSMENT AND CERTIFICATION


COUNCIL (TVET CDACC)

PRACTICAL ASSESSMENT
INSTRUCTIONS TO THE ASSESSOR
1. You are required to mark the practical as the candidate performs the tasks.
2. You are required to take video clips at critical points.
3. Ensure the candidate has an identification tag pinned at the back and front near the
shoulders showing Candidate’s name and registration code.

This assessor guide consists of 5 printed pages.

Page 1 of 5
© 2023 TVET CDACC

OBSERVATION CHECKLIST
Candidate’s name
& Registration
Code
Assessor’s name &
Registration Code
Venue of
Assessment
Date of assessment
Items to be evaluated: Please award marks as
Marks Marks
appropriate. Give a brief comment on your Comments
available obtained
observation.

TASK 1: ASSEMBLE TOOLS, MATERIALS AND EQUIPMENT AND SAFETY


1. Used personal Protective Equipment is in
line with occupational safety and health
requirements
• Gloves 3
• Apron
• Helmet
• Safety boots
(Award 1 mark for each PPE used or zero)
2. Identified materials according to job 1
requirement.
(Award 1 mark for material correct identification
and use or zero)
3. Identified materials required for piping 2
based on the drawings and positioning
correctly.
(Award 2marks for materials identified correctly
and positioning or zero)

Page 2 of 5
© 2023 TVET CDACC

TASK 2: INTERPRET ARCHITECTURAL DRAWING

4. Interpreted drawing based on the 2


specification
(Award 2 marks or zero)
5. Identified symbols based on the drawing. 3
(Award 1 mark for correct identified symbol or
zero)
TASK 3 INSTALL WATER PIPES AND SYSTEMS IN BUILDINGS.
6. Set out and marked positions of pipes based 1
on working drawings
(Award 1 mark or zero)
7. Threaded galvanized Iron pipes based on 3
best practices.
(Award 3marks for correct thread formed or
zero)
8. Joined pipes in accordance with best 1
practices and manufacturer’s instructions.
(Award 1 mark or zero)
9. Bended pipes based on type, drawing 2
specifications and requirements of the job.
(Award 2 marks for correct bending or zero)
10. Fitted pipes based on drawing 1
specifications.
(Award 1 mark or zero)
11. Positions of pipes are set out and marked 2
based on working drawings
(Award 2 marks or zero)
12. Conducted functionality tests based on best 2
practices.
(Award 2 marks or zero)
13. Proper waste disposal 2
(Award 2 marks or zero)

Page 3 of 5
© 2023 TVET CDACC

SUB-TOTAL 25

PRODUCT CHECKLIST
14. Measurements: 4
2600, 2000, 450 and 250
(Award 1 marks for each correct measurement or
zero)
15. Fitness of joints 4
(Award ½ mark for each or zero)
16. General appearance 4
(Award 1,2,3 or 4 marks or zero depending on
the degree of appearance)
17. Completeness 3
(Award 1,2 or 3 marks or zero depending on
degree completeness)
SUB-TOTAL 15

TOTAL 40

ASSESSMENT OUTCOME
The candidate was found to be:
Competent Not yet competent

(Please tick as appropriate)


(The candidate is competent if the candidate obtains at least 50%)
Feedback from candidate:

Feedback to candidate:

Candidate’s Signature Date

------------------------------ -----------------------------