Abstract
The BladeCenter HS22 is a two-socket blade server running Intel Xeon processors. It is ideal for mainstream
business applications including as a virtualization engine, and is compatible with the BladeCenter H, E, S,
and HT chassis. The HS22 supports up to two Intel Xeon 5500 or 5600 series multi-core processors, 12
DIMMs modules, two hot-swap drives, two PCI Express connectors, and one internal USB connector for
embedded virtualization.
Introduction
The BladeCenter HS22 is a two-socket blade server running Intel Xeon processors. It is ideal for mainstream
business applications including as a virtualization engine, and is compatible with the BladeCenter H, E, S,
and HT chassis. The HS22 supports up to two Intel Xeon 5500 or 5600 series multi-core processors, 12
DIMMs modules, two hot-swap drives, two PCI Express connectors, and one internal USB connector for
embedded virtualization.
• Documentation CD
• Environmental Notices CD
• Statement of Limited Warranty
• Important Notices
• Technical Note Flyer
Standard specifications
The following table lists the standard specifications.
Components Specification
Form factor Single-wide (30 mm)
Processor model Intel Xeon 5600 series processors, up to 3.6 GHz
Intel Xeon 5500 series processors, up to 2.80 GHz
Number of 1 standard / 2 maximum
processors
L3 cache Up to 12 MB L3 cache
Chipset Intel 5520 chipset
Memory DIMM 12x DDR-3 VLP DIMM slots
sockets
Maximum Models with Intel Xeon 5600 series processors: 192 GB using 16GB DIMMs
memory Models with Intel Xeon 5500 series processors: 96 GB using 8GB DIMMs
Expansion slots One CIOv slot: 2 ports
One CFFh slot: 4 ports
Disk controller LSI Logic 1064E SAS 3 Gbps controller, supports RAID-0 & RAID-1
Optional ServeRAID MR10ie with battery-backed write cache for internal and external
disk drives
Disk bays Two hot-swap 2.5-inch SFF bays supporting SAS HDDs or solid-state drives
(total/hot-swap)
Maximum Up to 2 TB total internal storage (using 1TB NL SAS or NL SATA drives)
internal storage
Network 2x 1Gb Ethernet using a Broadcom BCM5709S onboard NIC; supports TOE, failover
interface and load balancing, Wake on LAN, PXE boot
Some models also include a 2-port 10Gb controller installed in the CFFh slot (Emulex
10 GbE Virtual Fabric Adapter Advanced II or QLogic 2-port 10 Gb Converged
Network Adapter, depending on the model)
Hot-swap Internal storage bays
components
Systems Unified Extensible Firmware Interface (UEFI), Integrated Management Module (IMM),
management Predictive Failure Analysis, optional embedded hypervisor for virtualization, Active
Energy Manager, light path diagnostics, IBM Systems Director and ServerGuide
Video Matrox G200eV video core with 16 MB of video memory
Security Trusted Platform Module (TPM), Power-on password, administrator password,
unattended boot, selectable boot, unattended start mode
Operating Microsoft Windows, Red Hat Enterprise Linux, SUSE Linux Enterprise, VMware,
systems Oracle Solaris
supported
Limited warranty Three-year customer replaceable unit and on-site and off-site limited warranty
Standard models
The following table lists the standard models.
See the Standard specifications section for information about standard features of the server.
Chassis support
The HS22 is supported in the various BladeCenter chassis as listed in the following table.
The number of HS22 servers supported in each chassis depends on the thermal design power of the
processors used in the servers, as shown in Table 5. The table uses the following conventions:
• A green cell means the chassis can be filled with HS22 blade servers up to the maximum number of
blade bays in the chassis (for example, 14 blades in the BladeCenter H).
• A yellow cell means that the maximum number of HS22 blades that the chassis can hold is fewer
than the total available blade bays (for example, 12 in a BladeCenter H). Other bays in the chassis
may or may not be occupied by servers other than HS22 and HS22V depending on the combination
and some bays must remain empty. Consult the BladeCenter Interoperability Guide for specifics:
http://lenovopress.com/bcig.
Note: The HS22 is not supported in the BladeCenter E with power supplies smaller than 2000 W.
Processor options
The HS22 supports the processor options listed in the following table. The server supports one or two
processors. The table also shows which server models have each processor standard. If no corresponding
where used model for a particular processor is listed, then this processor is available only through Configure
to Order (CTO).
Memory options
Lenovo DDR3 memory is compatibility tested and tuned for optimal System x performance and throughput.
Memory specifications are integrated into the light path diagnostics for immediate system performance
feedback and optimum system uptime. From a service and support standpoint, Lenovo memory
automatically assumes the system warranty.
The HS22 has six DIMM sockets per processor (12 DIMMs in total) and uses Double Data Rate-3 (DDR-3)
very-low-profile (VLP) registered DIMMs. Servers with Intel Xeon 5600 series processors support 16GB
DIMMs meaning a total of up to 192 GB of RAM is supported. Servers with Intel Xeon 5500 series
processors support 8GB DIMMs meaning a total of up to 96 GB of RAM is supported. The memory DIMMs
connects directly to one of the processors. With one processor installed, only six DIMMs can be accessed.
To access memory in the other six DIMM connectors, the second processor must be installed.
The following two tables list memory options available for HS22 server: one of 5500 series processors and
one for 5600 series processors. DIMMs can be installed one at a time, but for performance reasons, install
them in sets of three (one for each of the three memory channels).
Table 7. Memory options for servers with Xeon 5500 series processors
Part number Feature Description Models
code where used
49Y1427 8928 1 GB (1x 1 GB, 1Rx8, 1.5 V) PC3-10600 CL9 ECC DDR3 1333 -
MHz
49Y1428 8929 2 GB (1x 2 GB, 2Rx8, 1.5 V) PC3-10600 CL9 ECC DDR3 1333 -
MHz
49Y1429 8930 2 GB (1x 2 GB, 1Rx4, 1.5 V) PC3-10600 CL9 ECC DDR3 1333 -
MHz
44T1594 A0YV 2 GB (1x 2 GB, 1Rx8, 1.5 V) PC3-10600 CL9 ECC DDR3 1333 -
MHz
46C0560 A0WX 2 GB (1x 2 GB, 1Rx8, 1.35 V) PC3L-10600 CL9 ECC DDR3 -
1333 MHz
49Y1430 8931 4 GB (1x 4 GB, 2Rx4, 1.5 V) PC3-10600 CL9 ECC DDR3 1333 -
MHz
44T1596 1908 4 GB (1x 4 GB, 2Rx8, 1.5 V) PC3-10600 CL9 ECC DDR3 1333 -
MHz
46C0563 A0WY 4 GB (1x 4 GB, 1Rx4, 1.35 V) PC3L-10600 CL9 ECC DDR3 -
1333 MHz
46C0564 A0WZ 4 GB (1x 4 GB, 2Rx8, 1.35 V) PC3L-10600 CL9 ECC DDR3 -
1333 MHz
49Y1431 8932 8 GB (1x 8 GB, 2Rx4, 1.5 V) PC3-10600 CL9 ECC DDR3 1333 -
MHz
Table 8. Memory options for servers with Xeon 5600 series processors
Part Feature Description Models
number code where
used
Standard DIMMs (1.5 V)
49Y1427 8928 1GB (1x 1GB, 1Rx8, 1.5V) PC3-10600 CL9 ECC DDR3 1333 -
49Y1428 8929 2GB (1x 2GB, 2Rx8, 1.5V) PC3-10600 CL9 ECC DDR3 1333 F2x, F3x, G2x,
G4x, GCx, H2x,
H4x, H5x, HAx,
N2x
49Y1429 8930 2GB (1x 2GB, 1Rx4, 1.5V) PC3-10600 CL9 ECC DDR3 1333 -
44T1594 A0YV 2GB (1x 2GB, 1Rx8, 1.5V) PC3-10600 CL9 ECC DDR3 1333 -
49Y1430 8931 4GB (1x 4GB, 2Rx4, 1.5V) PC3-10600 CL9 ECC DDR3 1333 -
49Y1431 8932 8GB (1x 8GB, 2Rx4, 1.5V) PC3-10600 CL9 ECC DDR3 1333 -
Low Power DIMMs (1.35 V)
46C0560 A0WX 2GB (1x 2GB, 1Rx8, 1.35V) PC3L-10600 CL9 ECC DDR3 1333 -
46C0563 A0WY 4GB (1x 4GB, 1Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333 A5x, A7x, B5x,
B6x, C5x, C6x,
C7x, C8x
46C0564 A0WZ 4GB (1x 4GB, 2Rx8, 1.35V) PC3L-10600 CL9 ECC DDR3 1333 -
46C0568 8644 8GB (1x 8GB, 2Rx4, 1.35V) PC3-10600 CL9 ECC DDR3 1333 -
46C0599 2422 16GB (1x16 GB, 2Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 -
1333
Note that although the maximum speed at which the memory channel runs on the HS22 is 1333 MHz, this
depends on a combination of three items:
• Processor memory speed: The processor has a maximum memory speed of 1333, 1066, or 800 MHz
depending on the processor model. Only the X (Advanced) range of Xeon 5500 and 5600 series
processors supports a maximum memory channel speed of 1333 MHz. See the processor options
(Table 5) for the maximum memory speed.
• Memory DIMM: Most but not all DIMMs listed in the previous tables support running at 1333 MHz.
Some only run at 1066 MHz. This is noted in the description of the DIMM.
• Number of DIMMs installed: The HS22 implements memory so that 2 DIMMs are on each of the
three memory channels of the processor. if only 1 DIMM is installed to each channel (that is, 3
DIMMs per processor) then the DIMMs can operate at the lower of the DIMM rated speed and
processor memory channel rated speed, up to 1333 MHz. However at 2 DIMMs per channel (6
DIMMs per processor), memory can only operate at 1333 MHz if Xeon 5600 X (Advanced) range of
processors (models X56nn) are installed. All other processors (all 5500, L56nn, and E56nn) cannot
drive the memory channel at 1333 MHz if there are 2 DIMMs per channel.
In summary, to ensure DIMMs operate at 1333 MHz, select a Xeon X56nn processor and use DIMMs that
are rated at 1333 MHz. All DIMMs in the proceeding table support running at 2 DIMMs per channel at 1333
MHz.
• ECC
• ChipKill
• Memory Mirroring
• Memory Sparing
Internal disk storage options
The HS22 blade server features an onboard LSI Logic 53C1064E 3 Gbps SAS controller with two hot-swap
drives bay accessible from the front of the blade server. The LSI Logic 53C1064E SAS controller provides
RAID 0 or RAID 1 capability and supports up to two internal hot-swap SAS or SATA HDDs or two internal
hot swap solid-state drives. The following table lists the hard drive options that are available for internal
storage.
Optical drives
The server does not support an optical drive option, however it does interface to the optical drive installed in
the BladeCenter chassis media tray if one is installed there.
The CIOv I/O expansion connector provides I/O connections through the midplane of the chassis to modules
located in bays 3 and 4 of a supported BladeCenter chassis. It is a PCIe 2.0 x8 slot.
The CFFh I/O expansion connector provides I/O connections to high-speed switch modules that are located
in bays 7, 8, 9, and 10 of a BladeCenter H or BladeCenter HT chassis, or to switch bay 2 in a BladeCenter S
chassis. The CFFh slot is a PCIe x16 slot.
The HS22 optionally supports the BladeCenter PCIe Gen 2 Expansion Blade. The expansion blade provides
the capability to attach selected PCI Express cards to the HS22. This capability is ideal for many
applications that require special telecommunications network interfaces or hardware acceleration using a
PCI Express card.
The expansion blade provides one full height and full length PCI Express slot and one full height and half
length PCI Express slot with a maximum power usage of 75 watts for each slot. It integrates PCI Express
card support capability into the BladeCenter architecture. Up to four expansion blades can be attached to an
HS22. Each expansion blade occupies a bay in the BladeCenter chassis.
The server also supports BladeCenter PCI Express I/O Expansion Unit (PCI Express Gen 1). A maximum of
one unit can be attached to a single blade.
For more information, see the following Lenovo Press Product Guides:
• BladeCenter PCI Express Gen 2 Expansion Blade and PCI Express Gen 2 Expansion Blade II at:
http://lenovopress.com/tips0783
• BladeCenter GPU Expansion Blade and GPU Expansion Blade II at:
http://lenovopress.com/tips0798
Network adapters
The HS22 offers two integrated Gigabit Ethernet ports, based on the Broadcom BCM5709S controller.
For more information, see the list of Lenovo Press Product Guides in the Ethernet adapters category:
https://lenovopress.com/servers/blades/nic
For more information, see the list of Lenovo Press Product Guides in the Fibre Channel adapters category:
https://lenovopress.com/servers/blades/hba
For information about this adapter, see the Lenovo Press Product Guide High IOPS SSD PCIe Adapters:
http://lenovopress.com/tips0729
Power supplies
Server power is derived from the power supplies installed in the BladeCenter chassis. There are no server
options regarding power supplies.
Integrated virtualization
The server supports VMware ESXi installed on a USB memory key. The key is installed in a USB socket
inside the server. The following table lists the virtualization options.
Remote management
The server contains an Integrated Management Module (IMM), which interfaces with the advanced
management module in the BladeCenter chassis. The combination of these two provides advanced service-
processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or
if a system component fails, LEDs on the system board are lit to help you diagnose the problem, records the
error in the event log, and alerts you to the problem. A virtual presence capability is also available for
remote server management capabilities.
The server also supports virtual media and remote control features, which provide the following functions:
• Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz, regardless of the
system state
• Remotely accessing the server using the keyboard and mouse from a remote client
• Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping
ISO and diskette image files as virtual drives that are available for use by the server
• Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive
• Capture blue-screen errors
See the ServerProven website for the latest information about the specific versions and service levels
supported and any other prerequisites:
http://www.lenovo.com/us/en/serverproven/nos/ematrix.shtml
Physical specifications
Dimensions:
Maximum weight: 5.4 kg (12 lb) (depending on the configuration when options are added)
Warranty options
The BladeCenter HS22 has a three-year on-site warranty with 9x5 next business day terms. Lenovo offers
the warranty service upgrades, discussed in this section. The ServicePac is a series of prepackaged warranty
maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services,
including service hours, response time, term of service, and service agreement terms and conditions.
ServicePac offerings are country-specific, that is, each country might have its own service types, service
levels, response times, and terms and conditions. Not all covered types of ServicePac might be available in a
particular country. For more information about ServicePac offerings available in your country visit the IBM
ServicePac Product Selector at https://www-304.ibm.com/sales/gss/download/spst/servicepac.
Term Description
On-site A service technician will come to the server's location for equipment repair.
repair (IOR)
24x7x2 hour A service technician is scheduled to arrive at your customer’s location within two hours after
remote problem determination is completed. We provide 24-hour service, every day,
including holidays.
24x7x4 hour A service technician is scheduled to arrive at your customer’s location within four hours after
remote problem determination is completed. We provide 24-hour service, every day,
including holidays.
9x5x4 hour A service technician is scheduled to arrive at your customer’s location within four business
hours after remote problem determination is completed. We provide service from 8:00 a.m.
to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding holidays. If
after 1:00 p.m. it is determined that on-site service is required, the customer can expect the
service technician to arrive the morning of the following business day. For noncritical service
requests, a service technician will arrive by the end of the following business day.
9x5 next A service technician is scheduled to arrive at your customer’s location on the business day
business day after we receive your call, following remote problem determination. We provide service from
8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding
holidays.
Regulatory compliance
The server conforms to the following international standards:
The external disk storage expansion enclosures listed in the following table are supported with the HS22.
For details about supported drives and cables for the Lenovo ThinkServer SA120, see the Lenovo Press
Product Guide:
http://lenovopress.com/tips1234
The external SAS cables listed in the following table support connectivity between external expansion
enclosures and the ServeRAID M5225 SAS/SATA Controller.
Table 17. External SAS cables for external storage expansion enclosures
Part number Description Maximum quantity supported
per one enclosure
Server to Expansion enclosure connectivity (Mini-SAS HD x4 to Mini-SAS x4)
00MJ162 0.6m SAS Cable (mSAS HD to mSAS) 1
00MJ163 1.5m SAS Cable (mSAS HD to mSAS) 1
00MJ166 3m SAS Cable (mSAS HD to mSAS) 1
Expansion enclosure to Expansion enclosure connectivity (Mini-SAS x4 to Mini-SAS x4)
39R6529 1 m SAS Cable 1
39R6531 3 m SAS Cable 1
The following table lists drives that are supported by EXP2512 external expansion enclosures.
The following table lists hard disk drives that are supported by EXP2524 external expansion enclosures.
For more information, see the list of Product Guides in the following categories:
• IBM Storage
https://lenovopress.com/storage/san/ibm
• Lenovo Storage
https://lenovopress.com/storage/san/lenovo
For more information, see the list of Product Guides in the Backup units category:
http://lenovopress.com/systemx/tape
We are dedicated to delivering a positive finance experience for customers like you who want to maximize
your purchase power by obtaining the technology you need today, protect against technology obsolescence,
and preserve your capital for other uses.
We work with businesses, non-profit organizations, governments and educational institutions to finance their
entire technology solution. We focus on making it easy to do business with us. Our highly experienced team
of finance professionals operates in a work culture that emphasizes the importance of providing outstanding
customer service. Our systems, processes and flexible policies support our goal of providing customers with
a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware
and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or
months later to add to your solution, we can consolidate everything into a single invoice.
Our Premier Client services provide large accounts with special handling services to ensure these complex
transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages
your account through its life, from first invoice through asset return or purchase. This specialist develops an
in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-
quality, easy, and positive financing experience.
For your region specific offers please ask your Lenovo sales representative or your technology provider
about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovo.com/services_warranty/us/en/financial_services.html
• Blade Servers
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other
countries, or both. A current list of Lenovo trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
BladeCenter Interoperability Guide
BladeCenter®
ServeRAID
ServerGuide
ServerProven®
System x®
ThinkServer®
X5
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United
States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.