bd14f-vsd-hd 109z0251 R134a 12-24vdc 03-2019 Desd101b422
bd14f-vsd-hd 109z0251 R134a 12-24vdc 03-2019 Desd101b422
4F-VSD-HD
Heavy Duty
Direct Current Compressor
R134a, 12/24V DC
General
Code number (without electronic units) 109Z0251
Electronic unit - Variable Speed 101N2100, 30 pcs: 101N2101
Approvals –
Compressors on pallet 180
Application
Application LBP/MBP/HBP
Evaporating temperature °F -20 to 59
Voltage range VDC 9.6 - 17 / 19 - 34
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (275) S = Static cooling normally sufficient
O = Oil cooling
Cooling requirements F1 = Fan cooling 1.5 m/s
Application LBP MBP HBP (compressor compartment temperature
32°C S S S equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
38°C S S S
SG = Suction gas cooling normally sufficent
43°C S S S – = not applicable in this area
Remarks on application:
HD (Heavy Duty) version of the BD1.4F-VSD which can handle extreme vibrations.
For more info please contact: [email protected].
Motor
Motor type permanet magnet, brushless DC
Speed variable speed
Resistance, all 3 windings (25°C) mΩ 210
Design
Displacement cu.in. 0.086
Oil quantity (type) fl.oz. 2.64 (polyolester)
Maximum refrigerant charge oz. 2.47
Free gas volume in compressor fl.oz. 17.60
Weight - Compressor/Electronic unit lbs. 4.63/0.24
Standard battery protection settings (refer to 101N2100 Instructions for optional settings)
Voltage (0.1 steps) Min. value Default Max. value
± 0.3V DC, Cut out VDC 9.6 10.4 17
12V
all values Cut in diff. VDC 0.5 1.3 10
± 0.3V DC, Cut out VDC 19 21.3 27
24V
all values Cut in diff. VDC 0.5 1.3 10
Dimensions
Height inch A 3.79
B 3.59
B1 3.46
B2 0.99
Suction connector location/I.D. inch | angle C 0.252-0259 | 25°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. inch | angle D 0.252-0259 | 25°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. inch | angle E 0.202-0.205 | 0°
material | comment Cu-plated steel | Al cap
Remarks: inch connectors
4,000 21 32 36 54 75 85 100 130 170 186 209 253 3 Motor start error
(The rotor is blocked or the differential pressure in the
Power consumption 12V DC, static cooling watt refrigeration system is too high (>5 bar)).
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59 2 Fan over-current cut-out
2,000 14 15 19 24 26 29 35 40 41 43 44 (The fan loads the electronic unit with more than
2,500 19 21 22 25 29 31 34 38 42 43 44 45 0.65Apeak).
3,000 22 24 26 30 36 38 41 46 51 52 53 54 1 Battery protection cut-out
3,500 25 29 31 37 44 46 50 55 60 62 63 65 (The voltage is outside the cut-out setting).
4,000 31 36 38 45 51 53 57 63 69 71 74 79
Wire Dimensions DC
Current consumption (for 24V applications the following must be halfed) A Size Max. length* Max. length*
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59 Cross AWG 12V operation 24V operation
section
2,000 1.31 1.39 1.65 1.90 2.00 2.15 2.41 2.71 2.82 2.96 3.23
[mm ]2
[Gauge] [m] [ft.] [m] [ft.]
2,500 1.51 1.62 1.68 1.95 2.28 2.42 2.63 2.96 3.25 3.33 3.40 3.45 2.5 12 2.5 8 5 16
3,000 1.78 1.97 2.06 2.40 2.76 2.91 3.14 3.49 3.82 3.92 4.03 4.17 4 12 4 13 8 26
3,500 1.95 2.25 2.38 2.85 3.32 3.51 3.78 4.20 4.58 4.69 4.81 4.95 6 10 6 20 12 39
4,000 3.17 3.24 3.29 3.56 3.93 4.11 4.38 4.86 5.37 5.55 5.75 6.05 10 8 10 33 20 66
*Length between battery and electronic unit
EER (ASHRAE LBP) 12V DC, static cooling BTU/h
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59 Accessories for BD1.4F-VSD-HD Code number
Bolt joint for one compressor Ø:16 mm 118-1917
2.000 2.88 3.19 4.06 4.78 5.06 5.49 6.29 7.39 7.88 8.58 10.17
2.500 1.88 2.95 3.33 4.32 5.09 5.38 5.83 6.66 7.79 8.29 9.00 10.57 Bolt joint in quantities Ø:16 mm 118-1918
Snap-on in quantities Ø:16 mm 118-1919
3.000 2.73 3.55 3.82 4.54 5.16 5.42 5.84 6.68 7.89 8.43 9.19 10.90
3.500 2.09 3.14 3.49 4.42 5.18 5.49 5.96 6.84 8.01 8.50 9.18 10.60 Terminal cover for electronic unit 105N9120
12V: 15A
4.000 2.36 3.09 3.36 4.19 5.00 5.34 5.87 6.83 8.03 8.51 9.15 10.40 Automoblie fuse Not
DIN 7258 24V: 15A deliverable
COP (EN 12900 Household/CECOMAF) 12V DC, static cooling W/W Main switch min. 20A from Secop
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59
2.000 0.69 0.77 0.97 1.14 1.21 1.31 1.50 1.76 1.88 2.04 2.42 Test conditions EN 12900 ASHRAE
2.500 0.45 0.77 0.89 1.23 1.52 1.62 1.79 2.09 2.50 2.68 2.94 3.53 CECOMAF LBP
Condensing temperature 131°F 130°F
3.000 0.62 0.90 1.00 1.29 1.54 1.64 1.80 2.10 2.52 2.70 2.96 3.55 Ambient temperature 90°F 90°F
3.500 0.46 0.83 0.96 1.29 1.56 1.66 1.81 2.10 2.48 2.64 2.87 3.35 Suction gas temperature 90°F 90°F
4.000 0.67 0.88 0.96 1.21 1.48 1.58 1.76 2.07 2.46 2.61 2.82 3.22 Liquid temperature no subcooling 90°F
Nidec GA Compressors accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Nidec GA Compressors reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this
material are the property of the respective companies. Secop and the Secop logotype are trademarks of Nidec Global Appliance Germany GmbH. All rights reserved. www.secop.com