M8301-90131 OpenLAB_CDS_ReleaseNotes-A.01.05
M8301-90131 OpenLAB_CDS_ReleaseNotes-A.01.05
Chromatography Data
System (CDS)
ChemStation Edition Version C.01.05
Release Notes
Notices Warranty Safety Notices
The material contained in this document is
© Agilent Technologies, Inc. 2010-2013
provided “as is,” and is subject to being CAUTION
No part of this manual may be reproduced in changed, without notice, in future editions.
any form or by any means (including electronic Further, to the maximum extent permitted by A CAUTION notice denotes a hazard.
storage and retrieval or translation into a applicable law, Agilent disclaims all It calls attention to an operating
foreign language) without prior agreement and warranties, either express or implied, with procedure, practice, or the like that, if
written consent from Agilent Technologies, Inc. regard to this manual and any information
as governed by United States and international contained herein, including but not limited to
not correctly performed or adhered to,
copyright laws. the implied warranties of merchantability and could result in damage to the product
fitness for a particular purpose. Agilent shall or loss of important data. Do not
Manual Part Number not be liable for errors or for incidental or proceed beyond a CAUTION notice
consequential damages in connection with
M8301-90131
the furnishing, use, or performance of this
until the indicated conditions are fully
document or of any information contained understood and met.
Edition herein. Should Agilent and the user have a
Second Edition, February 2013 separate written agreement with warranty
WARNING
Agilent Technologies, Inc. terms covering the material in this document
that conflict with these terms, the warranty
terms in the separate agreement shall A WARNING notice denotes a
control. hazard. It calls attention to an
Software Revision
operating procedure, practice, or the
This guide is valid for Agilent OpenLAB Technology Licenses like that, if not correctly performed
Chromatography Data System (CDS)
ChemStation Edition version C.01.05. The hardware and/or software described in or adhered to, could result in
this document are furnished under a license
and may be used or copied only in accordance
personal injury or death. Do not
with the terms of such license. proceed beyond a WARNING notice
Microsoft ® is a U.S. registered trademark of
until the indicated conditions are
Microsoft Corporation.
Restricted Rights Legend fully understood and met.
If software is for use in the performance of a
U.S. Government prime contract or
subcontract, Software is delivered and licensed
as “Commercial computer software” as
This product may be used as a component of an defined in DFAR 252.227-7014 (June 1995), or
in vitro diagnostic system if the system is as a “commercial item” as defined in FAR
registered with the appropriate authorities and 2.101(a) or as “Restricted computer software”
complies with the relevant regulations. as defined in FAR 52.227-19 (June 1987) or any
Otherwise, it is intended only for general equivalent agency regulation or contract
laboratory use. clause. Use, duplication or disclosure of
Software is subject to Agilent Technologies’
standard commercial license terms, and non-
DOD Departments and Agencies of the U.S.
Government will receive no greater than
Restricted Rights as defined in FAR 52.227-
19(c)(1-2) (June 1987). U.S. Government users
will receive no greater than Limited Rights as
defined in FAR 52.227-14 (June 1987) or DFAR
252.227-7015 (b)(2) (November 1995), as
applicable in any technical data.
Introduction
This document describes the functions, features and changes introduced with this and
previous releases of the Agilent OpenLAB Chromatography Data System (CDS)
ChemStation Edition product.
References to product documentation regarding known issues and workarounds are also
provided.
Version History
This provides a listing of the major feature modifications made in each release of
OpenLAB CDS ChemStation Edition.
Version C.01.05
New 7890B GC
This release of the RC.Net GC Driver 5.01 allows configuring the new Agilent 7890B and
includes the following system enhancements:
New Resource Conservation (Sleep/Wake)
New Early Maintenance Feedback (EMF)
Barcode Scanning with Auto-Input
In addition, the Data Store user interface has been redesigned to support the new
applications.
Version C.01.04
Version C.01.03
Sequence Planner
The Queue Planner is used to set up an ordered set of sequences (either ChemStation
sequence templates or Easy Sequences) and pauses. The Queue Planner allows you to
schedule lengthy routine tasks to run overnight or over a weekend.
Version C.01.02
Version C.01.01
Intelligent Reporting
OpenLAB CDS provides a new Intelligent Reporting feature for GC and LC ChemStation
data. The new intelligent reporting is provided in addition to classic reporting. The new
Intelligent Reporting allows you to create state-of-the-art reports in an industry standard
reporting format. You can easily create and modify report templates with the new Report
Template Editor built into the system that has an easy to use WYSIWYG interface. Report
templates are saved in the standardized Report Definition Language (RDL) format that is
also used by Microsoft Business Intelligence Studio.
When Intelligent Reporting is activated, a new Review view is available. It allows you to
apply any report template to any combination of data files.
New licensing
With OpenLAB CDS ChemStation Edition, a new licensing strategy is introduced that
helps you use your licenses more effectively. All instrument control, driver and Add-on
licenses are floating licenses. Any instrument that starts up requests licenses from
License Management, and when the instrument is closed, it returns the licenses. The new
licensing is based on Flexera Software™ SubScribeNet® technology. It simplifies your
software license management and license tracking and allows you to receive new or
urgent software and patch download information immediately after release.
Result sets: Containers are now called result sets. Methods that are used in result sets
may be modified during acquisition. You can create your own result sets using any
collection of existing data. You can use the user-assembled result sets, for example, for
cross sample calculations.
Method Handling: It is possible to directly load master methods and sequence methods
from the ChemStation explorer. The Update Methods dialog box allows you to
synchronize master methods and sequence methods.
Known Issues
For known issues and workarounds in the OpenLAB CDS ChemStation software at the
time of release see the Software Status Bulletin file named M83xxAA-SSB.html located on
Disc 2 of the OpenLAB CDS Installation media.
For known issues that have been resolved and/or closed with a workaround, see the
Software Release Bulletin file named M83xxAA-SRB.html located on Disc 2 of the
OpenLAB CDS Installation media.
You may also visit www.Agilent.com for up to date issue information for all Agilent
software products:
http://www.chem.agilent.com/en-US/Support/Downloads/Patches/Pages/default.aspx