**PURCHASE OF THIS DRAWING STRICTLY GRANTS YOU THE PERMISSION TO

CONSTRUCT THIS HOUSE ONLY AT THE ADDRESS IT IS SPECIFIED FOR. IT IS


STRICTLY PROHIBITED TO REPLICATE, DUPLICATE, OR REUSE THE DRAWING FOR
ANY OTHER PROPERTIES, INCLUDING ADDITIONAL ONES THAT MAY BE SIMILAR.
ANY REPRODUCTION OF THIS DRAWING FOR THE ADDRESS IT WAS NOT INTENDED
FOR IS A COPYRIGHT INFRINGEMENT

ROOF PITCH AS SHOWN

1'-0"
6'' TRIM 6'' TRIM

2'-0"

2'-0"
T/O ROOF PEAK 12 6'' TRIM ASPHALT SHINGLES
3 ROOFING

1'-0"
6'' TRIM 6'' TRIM

1'-0"
6'' TRIM 18" OVERHANGS (TYP.)
ROOF MIDPOINT

5'-0"
6'' TRIM 12 12
12 3 12 3 18'' FASCIA
HEEL HEIGHT TYP. 3 3
S S S S S S
1'-4"

T/O SECOND T/O SECOND 6" SHADOW BOARD


8'' BOXOUT 8'' BOXOUT 8'' BOXOUT
FLOOR CEILING FLOOR CEILING

VARIES
T/O WINDOW 4'' TRIM, 2'' PROUD

1'-6"

1'-6"
4'' TRIM AROUND DOORS
& WINDOWS
RAILING
9'-1"

3'-6" (MIN.) GLASS


8'-0"
24'-6 5/8" [7.48 M]

HAND RAIL STUCCO


-AS SHOWN
22'-4 3/8" [6.82 M]

12 1'-6"

8"
31'-95
3

1'-6"
12 ACCENT STUCCO VERANDA COLUMN DETAIL
3 -AS SHOWN SCALE: 1/4 " = 1'-0"
T/O SECOND FLOOR 8'' TRIM
T/O MAIN CEILING 8'' TRIM
T/O WINDOW PVC WOODGRAIN
FINISH CLADDING
12
1'-6"

3 -AS SHOWN

MANUFACTURED STONE 1'-0"


9'-1"

9'-1"
RAILING
8'-7"

W/ 4" TRIM
8'-0"

8'-7"

3'-6" (MIN.) GLASS

2'-0"
HAND RAIL COLUMN
CONSTRUCTION:
GLAZING GLAZING -18"x18" MANUFACTURED
STONE
T/O MAIN FLOOR GLAZING GLAZING -6"x6" BUILT UP 14"X14"
4"

VARIES
WOOD POST
-AS SHOWN/SEE DETAILS
5'-1" [1.55 M]

8'-0"
GLAZING GLAZING
8" DECORATIVE BEAM @
GLAZING GLAZING VERANDA & DECK

T/O FIN. GRADE (STEPS)


VERANDA ROOF DIMENSION
IS FROM UNDERSIDE OF SOFFIT
TO TOP OF MAIN FLOOR
FRONT COLUMN DETAIL
SCALE: 1/4 " = 1'-0"

T/O BASEMENT
GRADES ARE ESTIMATED
-VERIFY WITH PLOT PLAN

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES FRONT ELEVATION SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 3/16"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-1
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
ROOF VENTS
ROOF VENT SHOULD BE 4'-0" FROM
TRUSS BOTTOM CHORD

12
3
12 12
12 12 12
3 3
3 3 3
T/O SECOND FLOOR CEILING
T/O WINDOW
STUCCO

1'-6"
-AS SHOWN

ACCENT
STUCCO
9'-1"

8'-0"

-AS SHOWN

12 PVC
3 WOODGRAIN
12 FINISH
3 CLADDING
T/O SECOND FLOOR
-AS SHOWN
T/O MAIN CEILING

1'-6" 1'-1"
T/O WINDOW MANUFACTURED
STONE

RAILING
3'-6" (MIN.) GLASS
HAND RAIL
9'-1"

8'-0"

1'-0"

T/O MAIN FLOOR


T/O BASEMENT CEILING 8'' TRIM 8'' TRIM 8'' TRIM

VARIES
T/O WINDOW

VARIES
1'-6"
8'-9"

8'-0"

24" MAX. PARGING


PROVIDE NAILING STRIPS
IN FOUNDATION WALL
FOR DROPPED SIDING AS 1'-6"
REQUIRED
DECK COLUMN DETAIL DECK COLUMN DETAIL
T/O BASEMENT SCALE: 1/4 " = 1'-0" SCALE: 1/4 " = 1'-0"

IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES REAR ELEVATION SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 3/16"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-2
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
ELEVATIONS NOTES:
-CANTILEVERS WITHIN 1.2m OF THE PROPERTY
LINE MUST USE NON-COMBUSTIBLE CLADDING OR
MUST HAVE 12.7mm THICK EXTERIOR GYPSUM
BOARD UNDER CLADDING & MAINTAIN A 45 MINUTE
FIRE-RESISTANCE RATING OR WALL ASSEMBLY -
N.B.C. 2023 -A.E. 9.10.15.5(7).
-CANTILEVERS WITHIN 1.2m OF THE PROPERTY
LINE & WITH THE UNDERSIDE OF THE CANTILEVER
MORE THAN 0.6m ABOVE GRADE MUST BE
PROTECTED IN THE SAME WAY AS PROJECTING
SOFFITS - N.B.C. 2023-A.E. 3.2.3.6.5b & 9.10.15.5(8) &
9.10.15.5(10)
-SOFFITS WITHIN 1.2m OF PROPERTY LINE TO BE
0.44mm NON-VENTED ALUMINUM
-VENTING TO BE MADE UP IN OTHER LOCATIONS -
25% OF VENTILATION TO STILL COME FROM ROOF VENT SHOULD BE 4'-0" FROM
ROOF VENTS TRUSS BOTTOM CHORD
BOTTOM PORTIONS OF ROOF N.B.C. 2023-A.E.
12 STUCCO
3.2.3.6(5b) &9.10.15.5(8) & 9.10.15.5(10)
-FRAMER TO INSTALL 2 ROWS OF HORIZONTAL -AS SHOWN
3
BACKING TO SECURE CLADDING AT RETURN 12 12
MATERIAL LOCATIONS 3 ACCENT
3
12 12 12 STUCCO
3 3 3 -AS SHOWN
S S
T/O SECOND FLOOR CEILING
PVC
T/O WINDOW WOODGRAIN
2'-0" 2'-0"
2'-0" FINISH
CLADDING
-AS SHOWN

MANUFACTURED
9'-1"

8'-0"

STONE

12 12
3 3
T/O SECOND FLOOR
T/O MAIN CEILING
T/O WINDOW
2'-0"
12
3
9'-1"

8'-0"

RAILING
3'-6" (MIN.) HAND RAIL
4" MAX. VERTICAL SPACING

T/O MAIN FLOOR

10'-0"
8'' TRIM
8'-9"

2'-0"

24" MAX. PARGING VERANDA ROOF DIMENSION


PROVIDE NAILING STRIPS IS FROM UNDERSIDE OF SOFFIT
T/O BASEMENT IN FOUNDATION WALL TO TOP OF MAIN FLOOR
FOR DROPPED SIDING AS
REQUIRED

IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES LEFT ELEVATION SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 3/16"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-3
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
ELEVATIONS NOTES:
-CANTILEVERS WITHIN 1.2m OF THE PROPERTY LINE MUST USE
NON-COMBUSTIBLE CLADDING OR MUST HAVE 12.7mm THICK
EXTERIOR GYPSUM BOARD UNDER CLADDING & MAINTAIN A 45
MINUTE FIRE-RESISTANCE RATING OR WALL ASSEMBLY - N.B.C.
2023 -A.E. 9.10.15.5(7). SPATIAL SEPARATION CHART
-CANTILEVERS WITHIN 1.2m OF THE PROPERTY LINE & WITH THE
UNDERSIDE OF THE CANTILEVER MORE THAN 0.6m ABOVE GRADE TOTAL WALL AREA = 1403.21 SQ. FT.
MUST BE PROTECTED IN THE SAME WAY AS PROJECTING SEPARATING DISTANCE = ~10'-6" FT.
SOFFITS - N.B.C. 2023-A.E. 3.2.3.6.5b & 9.10.15.5(8) & 9.10.15.5(10)
-SOFFITS WITHIN 1.2m OF PROPERTY LINE TO BE 0.44mm ALLOWED OPENINGS (7%) = 98.22 SQ. FT.
NON-VENTED ALUMINUM TOTAL OPENINGS = 92.66 SQ. FT.
-VENTING TO BE MADE UP IN OTHER LOCATIONS - 25% OF
VENTILATION TO STILL COME FROM BOTTOM PORTIONS OF ROOF
N.B.C. 2023-A.E. 3.2.3.6(5b) &9.10.15.5(8) & 9.10.15.5(10) **THESE NUMBERS WILL BE ADJUSTED UPON FINAL
-FRAMER TO INSTALL 2 ROWS OF HORIZONTAL BACKING TO PLOT PLAN & SIZE OF WINDOWS MAY NEED TO BE
SECURE CLADDING AT RETURN MATERIAL LOCATIONS ADJUSTED
ROOF VENT SHOULD BE 4'-0" FROM
TRUSS BOTTOM CHORD 12
ROOF VENTS
STUCCO 12
3
-AS SHOWN 3
12
ACCENT STUCCO 3
-AS SHOWN
3/12 12
PVC WOODGRAIN
3
FINISH CLADDING
-AS SHOWN T/O SECOND FLOOR CEILING
T/O WINDOW
MANUFACTURED STONE
W/ 4" TRIM 2'-0"

RAILING
3'-6" (MIN.) GLASS

9'-1"
HAND RAIL

8'-0"
12
3 12
3
T/O SECOND FLOOR
T/O MAIN CEILING
T/O WINDOW
2'-0"
2'-0"
12
3

9'-1"
8'-0"
2'-0"

T/O MAIN FLOOR


8'-0"

T/O WINDOW

8'-9"
8'-0"
2'-0"
29'-0"
24" MAX. PARGING
PROVIDE NAILING STRIPS
IN FOUNDATION WALL
FOR DROPPED SIDING AS T/O BASEMENT
REQUIRED
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES RIGHT ELEVATION SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 3/16"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-4
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
SITE PLAN NOTES:

6'-6 3/4" [2.0 M]


118'-10 7/8" [36.2 M] **PURCHASE OF THIS DRAWING STRICTLY

6'-6 3/4" [2.0 M]


-ALL DIMENSIONS & CALCULATIONS TO BE GRANTS YOU THE PERMISSION TO CONSTRUCT
CONFIRMED BY A QUALIFIED SURVEYOR THIS HOUSE ONLY AT THE ADDRESS IT IS

10'-6 3/4" [3.2 M]


*PROTECH HOME DESIGN IS NOT RESPONSIBLE SPECIFIED FOR. IT IS STRICTLY PROHIBITED TO
FOR ANY DISCREPANCIES OR ERRORS THAT MAY REPLICATE, DUPLICATE, OR REUSE THE
RESULT .1 M] DRAWING FOR ANY OTHER PROPERTIES,
20'-0 5/8" [6 INCLUDING ADDITIONAL ONES THAT MAY BE

4'-0" [1.2 M]
6'-0" [1.8 M] 23'-0" [7.0 M]
SIMILAR. ANY REPRODUCTION OF THIS DRAWING
FOR THE ADDRESS IT WAS NOT INTENDED FOR IS
A COPYRIGHT INFRINGEMENT

10'-0" [3.0 M]
39'-2" [11.9 M]
3.0m
RIGHT OF
1 M] WAY
1/8" [8.
26'-7
2'-0" [0.6 M]

16'-4" [5.0 M]

29'-0" [8.8 M]
N
GARAGE

19'-0" [5.8 M]
1'-0" [0.3 M]
62'-1
1 5/8

]
.7 M
0" [6
9'-6" [2.9 M]
21'-1 HOUSE
" [19
.2 M
]

3'-0" [0.9 M]
6'-8" [2.0 M] 25'-0" [7.6 M]

8'-
6'-6" [2.0 M]

ENTRY

7'-0" [2.1 M]
CL

91
/4"
[2.
7'-6" [2.3 M]

7M
M]
/8" [5.8 1'-0" [0.3 M]

]
19 '-1 7
5'-6" [1.7 M]
1'-6" [0.5 M]
13'-8" [4.2 M]

11'-0" [3.4 M]
SITE COVERAGE - RU2 ZONING

LOT AREA = 7082.11 SQ. FT.


ALLOWED HOUSE/GARAGE- 55% = 3895.16 SQ. FT.
HOUSE/GARAGE ONLY = 2510.08 SQ. FT.
COVERED VERANDA = 46.25 SQ. FT.
REAR COVERED DECK = 168.00 SQ. FT.
34'-6" [10.5 M] AVAILABLE SITE COVERAGE = 1170.83 SQ. FT.

5'-0" [1.5 M]
NOTE: THE UNCOVERED PORTION OF THE DECKS
WOULD ONLY COUNT TOWARD THE SITE COVERAGE IF IT IS
M] 1.00m ABOVE GRADE AT ANY POINT.
2.2
12'-0" [3.7 M]

12'-0" [3.7 M]
] COVERED 12'-0" [3.7 M] 3
M "[
.6 DECK 5 '-7
[6 10
8"

5'-
1/

8
'- 9

1/8
21

"[
1.7
M]
14'-0" [4.3 M]
6'-
83
/4"
[2.

]
1M

M
.1
]

[6
2"
1/ SITE PLAN FOR ARCHITECTURAL DESIGN ONLY
35

'-0
'-7

20 PLEASE SEE SURVEY PLOT PLAN FOR PERMIT AND


3/
8"
[1

CONSTRUCTION
0.
9
M
]

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES SITE PLAN SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 1:100 APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-5
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
FOUNDATION NOTES:

-9'-0" FOUNDATION WALLS


-PROVIDE 30" DIAMETER SUMP PIT c/w PUMP, PUMP COVER, &
POWER SUPPLY - LOCATE NEAR OUTSIDE BASEMENT WALL
c/w DISCHARGE LINE & SPLASH PAD - CONNECT WEEPING
TILE & FLOOR DRAIN (c/w BACK WATER VALVE) TO PIT -
CONNECT DISCHARGE LINE TO STORM SEWERS WHERE
REQUIRED 70'-2"
-SEE ENGINEERED FLOOR LAYOUT FROM SUPPLIER FOR 45'-2" 25'-0"
COLUMN & PAD SIZING 39'-2" 6'-0" 23'-0" 2'-0"

1'-4"
7'-6" 14'-4" 17'-4"

BUCK DOWN FOR 8'-0" OVERHEAD DOOR


4'-0"
4" THICK CONCRETE SLAB ON

4'-6"

SL
TO

O
COMPACTED GRANULAR FILL

N
W

PE

AI
AR

D LAB
-SLOPE 2" TOWARD DRAIN

R
SL

D
D

AR S
S

AB

S
W PE
60"X32" 60"X32" D
R FLOOR

TO LO
AI DRAIN

10'-0"
N

S
1'-6"

8'-4"
SLIDER SLIDER

WINDOW HEIGHT WINDOW HEIGHT 18" CANTILEVER


8'-0" AFF 8'-0" AFF FOR PLUMBING
BUILD OUT

DROPPED ENGINEERED BEAM

DROPPED ENGINEERED BEAM


14'-9" 14'-2" 16'-3" 23'-0"

8'-9"

SUPPLIED BY SUPPLIER

SUPPLIED BY SUPPLIER
96"X60"

SL OW
SLIDER

1'-4"4"
N

T
O AR
AI
D LAB

PE D
R
D

SL S D
AR S
15'-1"

15'-1"

S
W PE

AB R
UNDER SLAB (MIN 100MM AND LESS THAN 10%
16'-4"

TO LO
GRANULAR FILL (RADON ROCKS) REQUIRED

A IN
OF MATERIAL THROUGH A 4MM SIEVE)

SL
20'-8"
TO

29'-0"
O

N
W

PE

AI
AR

D LAB
R
SL
11 7/8" I-JOIST

D
D

AR S
S

AB

S
W PE
@ 19.2" o.c. D
32'-10"

BUCK DOWN FOR 16'-0" OVERHEAD DOOR


TO LO
AI

7'-7"
N

S
28'-10"

FLOOR
DRAIN

16'-4"
19'-0"
2'-10"

48"X60"

SL
SLIDER
PLUMBING N TO
AI

O
W

AB
ROUGH-IN

PE
R AR
D

SL
46'-6"

46'-6"
SL
S D
10'-8" D S

PE

AB
AR 4" THICK CONCRETE SLAB ON D

O
W R

SL
AI
TO COMPACTED GRANULAR FILL N
3'-0"

-SLOPE 2" TOWARD DRAIN


9'-6"

13'-7"

13'-8"
4'-4" 5'-10" 3"

3'-6"
2'-8"

1'-4"
8'-4"
32"X80"

4"
SMOKE
1'-0"

ALARM/CO
UP
16R 6'-8" 25'-0"

3'-6"
4'-4" 5'-10" 3"
12" CL
3'-0"

6'-6"
7'-0"
PRECAST CONCRETE
LANDING/STEPS

10'-8" 5'-6" 4'-0"


DROPPED WING WALL
SLIDER

CONFIRM ON SITE
6'-8"

5'-3" 14'-2" 15'-1"

17'-6"
SUMP
13'-10"

CONCRETE PAD

13'-9"
13'-8"

13'-6"

UTILITY PUMP

FURN
FLOOR

11'-0"
DRAIN
SUMP PIT COVER
W/H
TO BE AIRTIGHT
120"X60"
7'-0"

HRV
CONCRETE PAD

RADON ELEC. PAN.

3'-3"

3'-6"
SIZED BY SUPPLIER
ENGINEERED BEAM
SIZED BY SUPPLIER
ENGINEERED BEAM

1'-0"1'-0" 7'-6" ENGINEERED BEAM SIZED BY SUPPLIER

11'-9" 3"

10'-6"
10'-3"
10'-6"

12'-0"
7'-0"

7'-0"

8'-6"
ENGINEERED BEAM
3"

3"

SIZED BY SUPPLIER
1'-6"

1'-6"

1'-6"
3" 13'-6" 3"

1'-6" 11'-0" 1'-6"


7'-6" 14'-0" 12'-0" 1'-0"
9'-6" 34'-6" 26'-2"
70'-2"

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES FOUNDATION PLAN SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 1/8"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-6
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
MAIN FLOOR NOTES:

-9'-1" WALLS
-TOP OF WINDOWS @ 80" A.F.F. (UNLESS NOTED)
-ALL CABINETS TO BE DESIGNED & CONFIRMED WITH
SUPPLIER
-ALL ANGLED WALLS ARE AT 45° (UNLESS NOTED)
-BEDROOM SMOKE DETECTORS TO BE INSTALLED WITHIN 1 70'-2"

METER OF DOORWAY 39'-2" 31'-0"


26'-0" 13'-2" 5'-6" 2'-0" 21'-6" 2'-0"
-CENTRE OF TOILET DRAIN TO BE 1'-2" FROM BACK WALL &
1'-4" FROM SIDE WALL / VANITY AS REQUIRED

1'-6"
REQUIRED

ENGINEERED BEAM SIZED BY SUPPLIER


NOTE:

-MOVE IF
ACCESS
ATTIC
60"X36"

4'-0"
GARAGE WALLS TO BE INSULATED,

4'-3"
4'-6"
TUB/SHOWER
VAPOUR BARRIER APPLIED & MINIMUM
11'-0" 15'-0" 3'-0" 10'-2" 5'-0" 12.7mm DRYWALL TO MEET ENGINEERED TRUSSES

8'0"X8'0" O/H DOOR


36"X40" 36"X40" N.B.C.-A.E.9.35.4.1 & 9.35.4.4 SIZED BY SUPPLIER

10'-0"
ENGINEERED BEAM SIZED BY SUPPLIER

H.R.V.
VS VS

2'-8"
WALL OVEN

8'-0"
2-CAR GARAGE

9'-6"
1'-6"

PLUMBING
22'-6" X 10'-0"

2x6 PLUMBING WALL


DW MICROWAVE BATH
5'-0" X 9'-0" FLOOR

WALL

6'-0"
COOKTOP 18" PLUMBING

CANTILEVER
DRAIN

2x6
7'-4"

7'-4"
LAM. BEAM
BUILD OUT

ENG. APP.
8'-9"

(FLUSH)
4'-0"

28"X80"
KITCHEN

RANGE
32"X80"
15'-0" X 14'-4"
SPICE KITCHEN 11 7/8" I-JOIST

1'-6" 6"
96"X72"
12'-8" X 6'-6"

SLIDER

1'-4"
@ 19.2" o.c.

1'-6"
32"X80"
ENGINEERED BEAM

RAILING
32"X80" SIZED BY SUPPLIER
10'-6" 5'-6"

16'-4"

2'-8"
42"x 60"
NOOK

4'-0"
WOOD

ENGINEERED BEAM SIZED BY SUPPLIER


10'-6" X 14'-4" MUDROOM LANDING

4'-0"

8'-0"
11'-6" X 5'-10"

16'0"X8'0" O/H DOOR

29'-0"
ENGINEERED BEAM SIZED BY SUPPLIER
DN
ENG. APP. LAM.

7R
11'-0" 11'-0" 4'-6" 2'-8" 5'-6" 6'-6"

4'-0"
BEAM (FLUSH)

2x6 BEARING
8'-0"
BENCH

2'-2"

BALCONY ABOVE
7'-7"

4'-2"
W/ HOOKS ABOVE

FRIG
ROD & SHELF

4'' DROPPED
LINE OF FLOOR ABOVE
FLOOR
DRAIN

16'-0"
19'-0"
18'-9"
2-CAR GARAGE

10'-6"
11'-0" 3'-2" 4'-0" 12'-0" 24'-6" X 18'-0"

2'-0"
13'-9" 14'-2" 16'-3" 17'-9" 7'-3"

ENG. APP. LAM.


DEN

BEAM (FLUSH)

8'-10"

8'-10"
ENG. APP. LAM. BEAM (FLUSH)
8" DROPPED CEILING ENG. APP. LAM. BEAM (FLUSH) 11'-2" X 8'-10"

5'-10"
LINE OF FLOOR ABOVE
11 7/8" I-JOIST
46'-6"

46'-6"
11'-6"
56"X80"
6'-6" @ 19.2" o.c.

96"X72"
OPEN TO ABOVE

SLIDER
ENG. APP. LAM.
BEAM (FLUSH) RAILING SMOKE
42'-6"

DINING ALARM/CO

14'-0"
13'-6" X 12'-6" 5'-4" 6'-8"
32"X80"
12'-6"

DN

3'-6"
16R
14'-0" 4'-0" 3'-10" 5'-10" 4'-6" DESK
ROD & SHELF

2'-8"

2'-8"

1'-6"
SLIDER

7'-4"

4"
2'-0" 2'-0" 48"X80"

7"
48"X48"
6'-0"

3'-0" 3'-8"

3'-6"

3'-10"
DN

64"X96"
UP FOYER 6'-8" 3R 25'-0"
2'-0"

16R 8'-10" X 7'-0"


ENG. APP. LAM. 3'-10" 5'-10" ENG. APP. LAM.

5'-4"

6'-6"
BEAM (FLUSH) DN
BEAM (FLUSH) 4R

8'-0"
RAILING LINE OF FLOOR ABOVE 7'-0"
2'-2"

SLIDER 5'-6" 4'-0" 9'-8" 9'-10" 5'-6" 4'-0"

7"

1'-6"
4'-0"

120"X72"

17'-6"
5'-6"
SLIDER
LINE OF FLOOR ABOVE
ENG. APP. LAM.
14'-0"
13'-8"

13'-8"

13'-8"

96"X72"
BEAM (FLUSH)
VE

VE
O

O
AB

AB

11'-0"
4'-0"

TO

TO
GREAT ROOM LIVING AREA
N

N
PE

PE
18'-0" X 14'-2" 15'-6" X 13'-2"
O

5'-6"
3'-6"

1'-6"
ELECTRIC FIREPLACE

10'-4" 2'-8" 1'-0" 1'-6"

32"X80"

3'-3"

3'-6"
SIZED BY SUPPLIER
ENGINEERED BEAM

ENGINEERED BEAM SIZED BY SUPPLIER

3"
SIZED BY SUPPLIER
ENGINEERED BEAM
10'-3"

10'-3"
10'-6"
12'-0"

12'-0"
COVERED DECK
13'-0" X 12'-0"

7'-0"

8'-6"
3" 13'-6" 3" 11'-9" 3"

ENGINEERED BEAM
3"

3"
SIZED BY SUPPLIER
1'-6"

1'-6"
1'-6" 11'-0" 1'-6"
1'-0" 8'-6" 7'-6" 14'-0" 12'-0" 1'-0"
9'-6" 34'-6" 26'-2"
70'-2"

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES MAIN FLOOR PLAN SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 1/8"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-7
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
SECOND FLOOR NOTES:
**PURCHASE OF THIS DRAWING STRICTLY GRANTS YOU THE PERMISSION TO
-9'-1" WALLS CONSTRUCT THIS HOUSE ONLY AT THE ADDRESS IT IS SPECIFIED FOR. IT IS
-TOP OF WINDOWS @ 80" A.F.F. (UNLESS NOTED) STRICTLY PROHIBITED TO REPLICATE, DUPLICATE, OR REUSE THE DRAWING FOR
-ALL CABINETS TO BE DESIGNED & CONFIRMED WITH ANY OTHER PROPERTIES, INCLUDING ADDITIONAL ONES THAT MAY BE SIMILAR.
SUPPLIER ANY REPRODUCTION OF THIS DRAWING FOR THE ADDRESS IT WAS NOT INTENDED
-ALL ANGLED WALLS ARE AT 45° (UNLESS NOTED) FOR IS A COPYRIGHT INFRINGEMENT
-BEDROOM SMOKE DETECTORS TO BE INSTALLED WITHIN 1
METER OF DOORWAY
-CENTRE OF TOILET DRAIN TO BE 1'-2" FROM BACK WALL &
1'-4" FROM SIDE WALL / VANITY AS REQUIRED
65'-2" 5'-0"
17'-8" 6'-4" 10'-8" 6'-0" 2'-8" 10'-0" 5'-10" 6'-0"
9'-1" 8'-7" 5'-4" 5'-4" 4'-6" 1'-6" 5'-0" 5'-0"

LINE OF FLOOR BELOW


48"X40" 48"X40" 24"X36" 48"X40"

SLIDER SLIDER VS SLIDER


ROD & SHELF ROD & SHELF

STANDING

8'' BOXOUT
60"X36"

TUB/SHOWER
36''x72''

2X6
ROD & SHELF
FREE

TUB
TUB/SHOWER

4'-6"

56"X80"
H.R.V.

5'-0"
ROD & SHELF
60"X36"
6'-6"

6'-10"
28"X80"

ENSUITE H.R.V. W.I.C.

36"X72"

24"X36"
10'-2"

ROD & SHELF

H.R.V.
FIXED

10'-6"
5'-2'' X 10'-0"

10'-10"
17'-2" X 9'-4"

11'-0"

11'-0"
BEDROOM - 4

2'-0"

VS
6'-4" 6'-4" 5'-0" 12'' 10'-0" X 10'-0"
BEDROOM - 3

ROD & SHELF


SEATING

13'-8"
10'-0" X 10'-6" 28"X80" RAILING
BATH

1'-10" 1'-10"

3'-8"
28"X80"
28"X80" 28"X80" 5'-6'' X10'-0"

6'-0"
16'-4"

24"X36"
3'-8"

H.R.V.

28"X80"
W.I.C.

VS
SMOKE SMOKE

28"X80"

28"X80"
MAKEUP 60"X36" 6'-0'' X 12'-10"

30"X80"5'-8"
SHOWER ALARM J & J BATH ALARM

6'-10"
6'-4" 4'-4" 6'-0'' / 8'-4" X 12'-10"
3'-4"

2'-0"
56"X80"

2'-10"

2'-0"
SMOKE

RAILING
48"X72"

SLIDER

2'-0"
3'-6"

30"X80"
ALARM

2'-8"

25'-0"
SMOKE
12" RAISED CEILING ALARM

SLIDER

84"X72"
28"X80"

1'-2"

4'-6"
6'-2"
ROD & SHELF 12" RAISED CEILING

3'-4"
15'-0" 9'-0" 6'-4" 4'-4" 8'-8" 4'-0"

5'-8"

19'-0"
9'-0"
4'-6"

4'-6"

4'-6"

56"X80"

8'' BOXOUT
56"X80"
4'-0" 9'-8" 9'-4" 9'-4" 16'-10"

BALCONY
4'' DROPPED
7'-6"

4'-6"
14'-2"
RAILING
MASTER BEDROOM - 1 MASTER BEDROOM - 2
LAUNDRY

RAILING

REQUIRED
13'-2" X 18'-2" 15'-0" X 13'-8"

-MOVE IF
ACCESS
6'-6"

3'-0"

ATTIC
9'-0" X 6'-0"

32"X80"
OPEN TO BELOW
96"X72"

SLIDER

F.D. 2'-0" 2'-0"

1'-4"
RAILING SMOKE

15'-2"

8'' BOXOUT
6'-10"
ALARM/CO
12'-6"

5'-0"
D W

2'-8"
DN LOFT

3'-6"
16R OPEN SHELVES

10'-8"

2'-0"
9'-0" X 14'-10" ABOVE
32"X80"
2'-0" 2'-0" 4'-0" 3'-10" 5'-10"

1'-0"
2x6 PLUMBING WALL

3'-6" 4"
5'-0" 4'-8" 15'-6" 7'-0" RAILING
6'-0"

8'' BOXOUT
RAILING

3'-5"
3'-10"

FIXED
54'-6"

54'-6"
14'-0" 13'-8" 9'-4" 5'-0" 20'-2" 1'-0"1'-0"
2'-0"

6'-6"
RAILING 1'-0" 4'-0"

60"X66"

3'-1"
FIXED
6'-8"

1'-6"
120"X72"

5'-6"
SLIDER
W

W
13'-6"

RAILING

13'-2"
LO

LO
13'-8"

BE

BE

22'-6"
TO

TO

11'-0"
N

N
PE

PE
6'-0"

8'' BOXOUT
O

O
7'-0"

29'-6"
5'-6"
RAILING
1'-6"

2'-3"
21'-0" 5'-0"
120"X72"

30"X72"
5'-6"

FIXED
SLIDER

5'-0"
8'' BOXOUT
6'-0"

2'-9"
BONUS ROOM
12'-0"

12'-0" X 12'-0"

3'-6"
8'' BOXOUT
FIXED

7'-0"
6'-0"

48"X72"

3'-6"

SLIDER

7'-0" 60"X72" 7'-0"


1'-0" 8'-6" 7'-6" 14'-0" 12'-0" 1'-0" 21'-2"
9'-6" 33'-6" 22'-2"
65'-2"

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES SECOND FLOOR PLAN SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 1/8"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-8
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
ROOF NOTES:

-ENSURE TRUSSES ARE STUBBED WHERE


SOFFITS DO NOT MEET WALL SHEATHING
-FALL PROTECTION IS REQUIRED

1'-6"
1'-6"

3/12 SLOPE
3/12 SLOPE
1'-6"
1'-6"

3/12 SLOPE

6"

1'-6"
1'-6" 3/12 SLOPE 3/12 SLOPE 3/12 SLOPE

3/12 SLOPE
8"

BOXOUT

6"

8"
6" BALCONY 1'-6"

3/12 SLOPE
1'-6" SADDLE

-MAINTAIN 1/8" PER 12" SLOPE TO

FLASHING/WATERPROOFING AS
8"

-CONFRIM ON SITE RAILING


3/12 SLOPE

-CONFIRM WITH SUPPLIER


REQUIRED BY SUPPLIER
6"

8"
1'-6"

DRAIN/SCUPPER
3/12 SLOPE 6"

BALCONY
8"

3/12 SLOPE

6"
S S S

8"

1'-6"
S
3/12 SLOPE
6"
PARAPET WALL
SCUPPERS
NOTE:
-SADDLES MAY BE REQUIRED TO
1'-6"

8" ENSURE DRAINAGE THROUGH


THE SCUPPERS

SADDLE

S
3/12 SLOPE
1'-6"

6"

BOXOUT
8"

PARAPET WALL

8"
3/12 SLOPE
1'-6"

S
SADDLE
3/12 SLOPE

6" 8" SCUPPERS


3/12 SLOPE

1'-6"

S
8"
1'-6"
S

6" 8"
3/12 SLOPE SCUPPERS
S
1'-6"

BOXOUT
PARAPET WALL

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES ROOF PLAN SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 1/8"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-9
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
STANDARD SPECIFICATIONS:
ROOF:
-ROOFING MATERIAL AS PER SPECIFICATIONS
-BUILDING PAPER
-3/8" O.S.B. c/w H-CLIPS
-ENGINEER APPROVED TRUSSES @24" o.c.
-UNLESS OTHERWISE SPECIFIED
12 -1x4 SPRUCE TRUSS BRACING @ 7'-0" o.c.
3 12 -NAILED TO BOTTOM CHORD
12 3 -MINIMUM 18 1/2" LOOSE FILL GLASS FIBRE
3 INSULATION c/w INSULATION STOPS
-6mil POLY VAPOUR BARRIER
12 -1/2" CD DRYWALL w/ CEILING FINISH
3 -PROVIDE EAVE PROTECTION TO MEET OR
ENGINEERED ROOF TRUSSES BY SUPPLIER EXCEED THE N.B.C.-A.E.
LINE OF 12" RAISED CEILING
1'-4"

-ALUMINUM EAVESTROUGH
12" RAISED CEILING -8" ALUMINUM FASCIA ON 2x8 WOOD BACKING
-UNLESS OTHERWISE SPECIFIED
-VENTED ALUMINUM SOFFITS
-ATTIC TO BE VENTED 1:300 OF INSULATED
CEILING AREA
EXTERIOR WALLS:
-EXTERIOR FINISH AS PER ELEVATIONS
9'-1"

-BUILDING PAPER
-3/8" O.S.B. EXTERIOR SHEATHING
-2x6 KILN DRIED SPRUCE STUDS @ 24" o.c.
-OR 2x6 KILN DRIED SPRUCE STUDS @ 16" o.c.
WHEN FIRE-RATED WALL WITH SIDING IS
REQUIRED
-FRICTION FIT BATT INSULATION
FLUSH ENG. BEAM -6mil POLY VAPOUR BARRIER
ENGINEERED FLOOR JOISTS SIZED BY SUPPLIER
SIZED BY SUPPLIER -1/2" INTERIOR GYPSUM WALLBOARD
12 INTERIOR PARTITION WALLS:
ENGINEERED BEAM
3-1/2" GYPSUM WALLBOARD
SIZED BY SUPPLIER -2x4 STUDS @ 24" o.c.
-UNLESS OTHERWISE NOTED

1'-10"
-1/2" GYPSUM WALLBOARD
FOUNDATION WALL:
9'-1"

9'-1"

1"
-6mil POLY VAPOUR BARRIER

7'-112
-R20 FRICTION FIT BATT INSULATION
-2x6 FROST WALL STUDS @ 24" o.c. OFFSET
1/2" FROM CONCRETE WALL
-8" WIDE CONCRETE WALL c/w
2 HORIZONTAL ROWS OF MINIMUM 10M
STEEL REBAR TOP & BOTTOM ON MINIMUM

9'-0"
OF 18"x8" CONCRETE STRIP FOOTING
-EXTERIOR DAMPPROOFING
ENGINEERED ENGINEERED -FOOTING TO BE PLACED ON UNDISTURBED
BEAM SIZED BY BEAM SIZED BY
OR COMPACTED SOIL - MINIMUM 4'-0"

5'-5"
SUPPLIER SUPPLIER

8"

8"
4'-43

4'-43
BELOW GRADE
-ALL CONCRETE TO BE MINIMUM OF 20MPa-
TYPE 10 c/w 25mm AGGREGATE

1'-0"
FRAMED FLOOR:
9'-0"

FLOOR DRAIN
-ENGINEERED FLOOR JOISTS
AS PER SUPPLIER
-23/32" O.S.B. FLOOR SHEATHING
TO BE GLUED AND SCREWED

MIN.
4'-0"
BASEMENT FLOOR:
-MINIMUM 3" THICK 20MPa TYPE 10
CONCRETE c/w 25mm AGGREGATE
-8" CRUSHED GRAVEL
-6mil VAPOUR BARRIER

8"
STEPPED
MIN.
4'-0"

FOOTING
GARAGE SLAB:
TO SUIT GRADE -HAND TROWELLED 4" CONCRETE SLAB
REINFORCED w/ 10M STEEL REBAR
@24" o.c. E.W. PLACED 24" INTO FOUNDATION
8"

WALL ONLY (SLOPE 2" TOWARD DRAIN)


INSULATED CEILING ABOVE GARAGE SPACE:
-6mil POLY VAPOUR BARRIER
-2x6 KILN DRIED SPRUCE STUDS @ 24" o.c.
-FRICTION FIT BATT INSULATION
-1/2" INTERIOR GYPSUM BOARD
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES CROSS SECTION A SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 3/16"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-10
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
GENERAL NOTES: -ALL BEAMS TO BE DESIGNED BY SUPPLIER AND GARAGE TO BE 1 HR. FIRE-RATED AND GAS-PROOFED TO TO BE VERIFIED WITH A QUALIFIED SURVEYOR **PURCHASE OF THIS DRAWING STRICTLY GRANTS YOU THE PERMISSION TO
-SEE ENGINEER'S LAYOUT MEET CODE -GLASS SHOWER DOOR / WALLS MUST BE TEMPERED GLASS CONSTRUCT THIS HOUSE ONLY AT THE ADDRESS IT IS SPECIFIED FOR. IT IS
-ALL CONSTRUCTION TO CONFORM TO LOCAL BYLAWS AND THE -PRECAST CONCRETE STEPS OR CAST-IN-PLACE AS PER PLAN -WEEPING TILE TO BE INSTALLED AROUND ALL STRIP FOOTINGS -PLUMBING ACCESS OF MINIMUM 16"x 20" TO BE PROVIDED FOR
N.B.C. 2023-A.E. **IN ANY INSTANCE OF DISCREPANCIES UNLESS OTHERWISE SHOWN AND TIED TO DRAINAGE SYSTEM EACH TUB & SHOWER STRICTLY PROHIBITED TO REPLICATE, DUPLICATE, OR REUSE THE DRAWING FOR
BETWEEN THIS PLAN & THE N.B.C. THE N.B.C. 2023-A.E., THE -ENTRANCE DOORS TO BE SOLID CORE IN ACCORDANCE WITH -GARAGE PILE LAYOUT (IF REQUIRED) TO BE DESIGNED & -DRYER VENT TO BE 4" DIAMETER c/w HOOD ANY OTHER PROPERTIES, INCLUDING ADDITIONAL ONES THAT MAY BE SIMILAR.
N.B.C. 2023-A.E. WILL OVERRIDE N.B.C. 2023-A.E. BUILDING CODE 9.7.2.1. VERIFIED BY A QUALIFIED STRUCTURAL ENGINEER -ALL EXHAUST FANS TO VENT TO EXTERIOR ANY REPRODUCTION OF THIS DRAWING FOR THE ADDRESS IT WAS NOT INTENDED
-EXTERIOR WALLS ARE SHOWN AS 6" THICK AND INCLUDE AN -INTERIOR DOOR FRAMING HEIGHT TO BE 83" FOR 80" DOOR, -ATTIC ACCESS TO BE MINIMUM 21 1/2"x 23" AS PER N.B.C. 2023 - -PROVIDE FRESH AIR INTAKES FOR ALL FURNACES & FOR IS A COPYRIGHT INFRINGEMENT
ALLOWANCE FOR 1/2" OF SHEATHING ON THE EXTERIOR 99" FOR 96" DOOR A.E. c/w WEATHERSTRIPPING AND INSULATION FIREPLACES
-INTERIOR WALLS ARE SHOWN AS 3 1/2", 5 1/2", OR 7 1/4" THICK -PROVIDE SELF-CLOSER ON GARAGE-HOUSE DOOR, c/w -ROOF VENTS TO BE PROVIDED TO MEET CODE -COMBUSTION AIR FOR THE FIREPLACE MUST BE SUPPLIED BY
-WALLBOARD REDUCES THE ROOM SIZES WEATHERSTRIPPING -INSULATION STOPS TO BE INSTALLED AS REQUIRED AIR INTAKES OTHER THAN A DOOR OR A WINDOW
-ALL WALLS 11'-10" OR TALLER REQUIRE AN ENGINEER'S -ALL WINDOWS SUBJECT TO LOCAL BYLAWS AND MUST MEET -SMOKE / CARBON MONOXIDE DETECTORS TO BE PROVIDED TO -DECK SLOPE = MIN. 1/8" PER 12", MAX. 1/4" PER 12"
APPROVAL /DETAIL CODE FOR EGRESS IN REQUIRED ROOMS MEET CODE -ALL WORKMANSHIP TO BE A STANDARD EQUAL OR BETTER IN
-ALL DIMENSIONS ARE TAKEN TO THE FACE OF THE INTERIOR -WINDOW SIZES SHOWN ARE APPROXIMATE AND SHOULD BE -FLASHING TO BE INSTALLED TO MEET CODE & LOCAL ALL RESPECTS TO GOOD BUILDING PRACTICE IN ACCORDANCE
STUDS AND OUTSIDE FACE OF SHEATHING ON EXTERIOR WALLS VERIFIED WITH THE BUILDER / CONTRACTOR / OWNER PRIOR TO REQUIREMENTS WITH THE NATIONAL BUILDING CODE 2023 ALBERTA EDITION
AND OUTSIDE FACE OF CONCRETE WALLS ORDERING / INSTALLATION - INCLUDING ROUGH OPENINGS / -PROVIDE FLASHING ABOVE ALL EXTERIOR DOORS, WINDOWS, &
-DESIGN IS BASED ON AN ENGINEERED FLOOR SYSTEM STYLE / TYPE / GRILLES OPENINGS
-SEE ENGINEER'S LAYOUT -ALL WINDOWS 8'-0" AND OVER TO HAVE LINTEL SIZED BY -GRADE LINES ARE ESTIMATED ONLY AND SHOULD BE VERIFIED
-DESIGN IS BASED ON AN ENGINEERED ROOF TRUSS SYSTEM SUPPLIER WITH PLOT PLAN AND / OR GRADES ON SIDE - ENTRY STEPS TO
-SEE ENGINEER'S LAYOUT -ALL OVERHANGS SUBJECT TO LOCAL BYLAWS BE ADJUSTED ACCORDINGLY
-ALL WALLS / CEILINGS / FLOORS THAT ARE COMMON TO HOUSE -MAIN FLOOR ELEVATIONS TO TOP OF GARAGE SLAB ELEVATION

12
3
12
3

12 12
3 3
1'-4"

ENGINEERED ROOF TRUSSES BY SUPPLIER


12" RAISED CEILING

1'-6"
THIS PORTION TO BE
COMPLETE WHEN
9'-1"

9'-1"
BASEMENT DEVELOPMENT
IS COMPLETED

MAIN FLOOR

8x8 SMART
12 BOARD BACKER
TERMINATION TO BE
3 CAPPED/LABELED
MIN. 4" PROJECTION
(FOR DEVELOPED
SECTION TO BE COMPLETED BY BASEMENT ONLY)
CUSTOMER AFTER POSSESSION
GRADE LINE
NOTE:
ENGINEERED FLOOR JOISTS SIZED BY SUPPLIER BASEMENT BUILDER TO CONFIRM
VENTING LOCATION
FLUSH ENG. BEAM BASED ON REQUIRED
SIZED BY SUPPLIER CLEARANCES
3"-20MPA CONC. SLAB ON
6 mil POLY
AIR BARRIER (MIN. 12"
LAPPED)
OVERCOMPACT GRAVEL

FLOOR SLAB
TERMINATIONS

CENTRE OF
TO MATCH TOP OF
TO BE
FOOTING (APPROX. 5") CAPPED/LABELED
BASEMENT
9'-1"

9'-1"
CONCRETE SLAB

PERFORATED 4" EXHAUST


WEEPING TILE PIPE

SEALANT
4" SOLID VERTICAL PIPE c/w 90D
ELBOW & 4" SOLID HORIZONTAL PIPE
TO BE CONNECTED TO PERFORATED
WEEPING TILE WITH CONNECTOR

4"
RADON MITIGATION DETAIL
ENGINEERED FLOOR JOISTS SIZED BY SUPPLIER SCALE: 1/4"=1'-0"
ENGINEERED BEAM SIZED BY SUPPLIER
9'-0"

IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE


EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA
NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE
BUILDER / CONTRACTOR / OWNER.

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES CROSS SECTION B SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 3/16"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-11
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
STEPS FOR WINDOW INSTALLATION

STEP ONE STEP TWO STEP THREE

12"

MIN.
6"
12"

4"
APPLY SILL FLASHING
SILL EXTEND BUILDING PAPER OVER BUILDING PAPER
PAPER HORIZONTALLY 12" TO PROJECT AT SILL & CORNER
BEYOND VERTICAL JAMB FLASHING PATCHES AS SHOWN
INSTALL SELF-STICKING MEMBRANE OVER
APPLY BUILDING PAPER HORIZONTALLY BELOW SILL VULNERABLE CORNER INTERSECTIONS -SILL FLASHING CAN BE ADHESIVE MEMBRANES IF
-FASTEN TOP EDGE OF BUILDING PAPER TO WALL ASPHALT IMPREGNATED FELT OR COATED PAPER
SHEATHING - DO NOT FASTEN TO LOWER EDGE -DO NOT USE ADHESIVE BITUMEN-BASED MEMBRANES
-DRAINAGE PLANE TO BE SLID UP & UNDER LATER WITH PLASTIC HOUSEWRAP - USE BUILDING PAPER
BUILDING PAPER IN SHINGLE FASHION

STEP FOUR STEP FIVE STEP SIX

APPLY CONTINUOUS SEAL TO TOP & SIDES


OF OPENING TO ASSURE CONTACT WITH INSTALL DRAINAGE PLANE OVER HEAD 6" MIN. VERTICAL LAP
MOUNTING FLANGE OF WINDOW FLASHING & TOP OF NAIL-ON HEAD ON DRAINAGE PLANE
6"
FLANGE OF WINDOW FRAME

SEAL FRAME SEAM JOINTS APPLY BLUE GOO


AT CORNERS AFTER SEALANT ALONG
INSTALLATION TOP & SIDE EDGES

4"
OF WINDOW
4" MIN. HORIZONTAL LAP
ON DRAINAGE PLANE

SLIP DRAINAGE PLANE UNDER


JAMB FLASHING & SILL FLASHING
DO NOT SEAL BOTTOM AT BOTTOM OF WINDOW SILL
OF WINDOW TO SILL
-SHIM & ADJUST WINDOW TO BE SQUARE, PLUM & LEVEL FLASHING
-USE CORROSION RESISTANT FASTENERS NO CLOSER NOTE:
THAN 3" FROM EVERY CORNER - ALL WINDOWS SHALL BE INSTALLED AS PER NBC
-SECURE WINDOW WITH EQUIVALENT OF 6d FASTENERS 2023-A.E. 9.8.8.1. (4) & (5)
AT 16" o.c. MAXIMUM

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES WINDOW DETAILS SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 NOT TO SCALE APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-12
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
6 mil VAPOUR 6 mil VAPOUR
BARRIER CLADDING AS PER SPEC. BARRIER CLADDING AS PER SPEC.
WEATHER BARRIER BUILDING WEATHER BARRIER BUILDING 6 mil POLY 6 mil POLY VAPOUR CLADDING
-CONTINUOUS PAPER (LAP OVER FLASHING) PAPER (LAP OVER FLASHING) VAPOUR CLADDING AS PER SPEC. BARRIER AS PER
SEALANT OR -CONTINUOUS BARRIER
-CONTINUOUS SPEC.
ADHESIVE AS SEALANT OR -CONTINUOUS WEATHER BARRIER BUILDING -CONTINUOUS
ADHESIVE AS SEALANT OR WEATHER
SHOWN SEALANT OR PAPER (LAP OVER FLASHING) SEALANT OR
SHOWN ADHESIVE AS BARRIER
ADHESIVE AS ADHESIVE AS
SHOWN BUILDING
FLOOR JOISTS (AS PER SHOWN SHOWN
LOOSE-LAID BATT INSULATION 6 mil VAPOUR LOOSE-LAID BATT INSULATION PAPER
MANUFACTURER) (LAP OVER
6 mil VAPOUR RIMBOARD BARRIER RIMBOARD FLASHING)
BARRIER LOOSE-LAID INSULATION
15" WIDE 3/8" OSB LADDER CAP -CONTINUOUS 15" WIDE 3/8" OSB LADDER CAP FLOOR JOISTS RIMBOARD RIMBOARD
SEALANT OR (AS PER
ADHESIVE AS MANUFACTURER) -CONTINUOUS
SEALANT SHOWN SEALANT -CONTINUOUS SEALANT OR
12"-16" LAP

12"-16" LAP
6 mil VAPOUR 6 mil VAPOUR SEALANT OR ADHESIVE AS
6" MIN.

6" MIN.
BARRIER FOUNDATION LADDER BARRIER FOUNDATION LADDER ADHESIVE AS SHOWN

12"-16" LAP

12"-16" LAP
2x6 FROST WALL W/ 2x6 FROST WALL W/ SHOWN
BATT INSULATION BATT INSULATION ACOUSTIC
6 mil POLY VAPOUR 6 mil POLY VAPOUR SEALANT TO BE
AIRSPACE AIRSPACE BARRIER BARRIER
ACOUSTIC SEALANT TO BE USED USED IN ALL
8" CONCRETE WALL 8" CONCRETE WALL
IN ALL LOCATIONS TO PROVIDE LOCATIONS TO
ACOUSTIC SEALANT TO BE USED PARGING ACOUSTIC SEALANT TO BE USED PARGING
A COMPLETE VAPOUR BARRIER PROVIDE A
IN ALL LOCATIONS TO PROVIDE IN ALL LOCATIONS TO PROVIDE
DAMPROOFING DAMPROOFING COMPLETE
A COMPLETE VAPOUR BARRIER A COMPLETE VAPOUR BARRIER
VAPOUR BARRIER
AIR & VAPOUR SEALING @ FOUNDATION JUNCTION AIR & VAPOUR SEALING @ FOUNDATION JUNCTION AIR & VAPOUR SEALING @ FLOOR JUNCTION AIR & VAPOUR SEALING @ FLOOR
(PERPENDICULAR TO JOISTS) (PARALLEL TO JOISTS) (PERPENDICULAR TO JOISTS) JUNCTION
(PARALLEL TO JOISTS)

ENGINEERED ROOF TRUSSES BY SUPPLIER

ENGINEERED ROOF TRUSSES BY SUPPLIER


6 mil VAPOUR O.S.B.
BARRIER CLADDING AS PER SPEC.
WEATHER BARRIER BUILDING O.S.B. ENSURE SYNTHETIC
8" CONCRETE WALL DBL. FOUNDATION
PAPER (LAP OVER FLASHING) BUILDING PAPER
LADDER TO BE OVERLAPS BUILDING
HALF JAMB
REMOVED PRIOR TO PLYWOOD BOX TOP FLASHING
2x6" FROST WALL PAPER AT TOP
FLOOR SLAB POUR
w/ INSULATION w/ END DAM
-CONTINUOUS PEEL & STICK MEMBRANE
-CONTINUOUS FLASHING WALL PENETRATION
6 mil VAPOUR FILL BOX WITH SEALANT OR
SEALANT OR 2 1/2" RIGID INSULATION
BARRIER RIGID SL INSULATION ADHESIVE AS BOTTOM FLASHING
ADHESIVE AS

2'-0"
-CONTINUOUS DOWN TO FOOTING SHOWN CAULKING w/ END DAM
SHOWN AS REQUIRED (R60)
SEALANT OR
ADHESIVE AS FOUNDATION PRE-MANUFACTURED WALL ENSURE SYNTHETIC
LADDER TRUSS
SHOWN PLATE (INSTALL PRIOR TO BUILDING PAPER
MDF BOTTOM BOTTOM
SEALANT 8'-0" LONG 10M SIDING) OVERLAPS BUILDING
CHORD
REBAR @ 24" o.c . PAPER BELOW
6 mil VAPOUR PARGING
ACOUSTIC SEALANT TO BE USED SYNTHETIC BUILDING BUILDING PAPER
BARRIER DAMPROOFING 6 mil PAPER BEHIND WALL PLATE
IN ALL LOCATIONS TO PROVIDE RUBBER GASKET
AGGREGATE AS VAPOUR CASING (EXTEND MIN.6" AROUND)
A COMPLETE VAPOUR BARRIER HALF JAMB BLOCKING
PER BARRIER
NBC-AE 9.16.2.1(1) SLAB ABOVE FROST LINE DETAIL ATTIC ACCESS ATTIC ACCESS (PLAN VIEW)
SLAB / FOOTING JUNCTION WALL PENETRATION
EXTERIOR WALL ASSEMBLY ACOUSTIC SEALANT TO BE USED
AS REQUIRED IN ALL LOCATIONS TO PROVIDE
SEALED AS PER VENT PIPE
A COMPLETE VAPOUR BARRIER CLADDING AS PER SPEC.
9.36.2.10(15)
-CONTINUOUS WEATHER BARRIER BUILDING
SEALANT OR PAPER (LAP OVER FLASHING)
ADHESIVE AS SPRAY FOAM @
6 mil VAPOUR SHOWN WIRE PENETRATION
BARRIER
6 mil VAPOUR
BARRIER 6 mil VAPOUR 2x6 PLUMBING WALL
-CONTINUOUS BARRIER
SEALANT OR 6 mil BLOCKING
-CONTINUOUS
ADHESIVE AS VAPOUR
INTERIOR WALL SEALANT OR
SHOWN BARRIER ACOUSTIC SEALANT TO BE USED 6 mil PEEL & STICK (OR EQUIVILANT)
ADHESIVE AS BLOCKING 1/2" GD BOARD OUTLET BOX
IN ALL LOCATIONS TO PROVIDE TO ENSURE AIR BARRIER SEALED
SHOWN VAPOUR
POLY HAT AT PENETRATION
A COMPLETE VAPOUR BARRIER BARRIER AS PER 9.36.2.10(5) & (7)
INTERIOR / EXTERIOR WALL CONNECTION INTERIOR WALL @ CEILING VENT PIPE PENETRATION TYPICAL OUTLET BOX TYPICAL OUTLET BOX
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES ENERGY DETAILS SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 3/4"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-13
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
SOLID ~APPROVED SEALANT AT MECHANICAL JOINTS MUST BE
COMPRESSIVE MECHANICALLY COMPRESSED BETWEEN SOLD BACKING
FRAMED WALL FRAMED WALL ~HOLES OR JOINTS IN POLY AIR/VAPOUR BARRIER
COMPONENT SPACING AS PER SPEC SPACING AS PER SPEC CANNOT BE SEALED WITH SEALANT OR TAPE UNLESS
THERE IS SOLD BACKING SUPPORT BEHIND & A
COMPRESSING COMPONENT DRYWALL / WOOD / OSB)
OVER TOP
SOLID BLOCKING/BACKING SOLID BLOCKING/BACKING -TRACE DUCT/WALL
RIM JOIST PENETRATION WALL PENETRATION PENETRATION WITH
PERMANENT MARKER
CONTINUOUS SEALANT c/w
SOLID COMPRESSING -CUT INTERSECTING
COMPONENT OVER TOP LINES INSIDE CIRCLE
CONTINUOUS SEALANT
FRAMED/FROST WALL -PUSH DUCT THROUGH
SPACING AS PER SPEC POLY
SOLID COMPRESSIVE
COMPONENT
-TAPE FLAPS TO
INSULATION NOT SHOWN INSULATION NOT SHOWN OUTSIDE OF DUCT
TO ENHANCE CLARITY TO ENHANCE CLARITY
CROSS SECTION INTERIOR ELEVATION CROSS SECTION INTERIOR ELEVATION

AIR & VAPOUR SEALING @ RIM JOIST PENETRATION AIR & VAPOUR SEALING @ WALL PENETRATION AIR & VAPOUR BARRIER RECOMMENDED CUT PATTERN
6 mil VAPOUR CLADDING AS PER SPEC. WATERLINES TIGHT AS POSSIBLE TO FLOOR SHEATHING
ACOUSTIC SEALANT TO BE USED BARRIER -ALWAYS INSTALL ON THE FAR SIDE OF THE SECOND
IN ALL LOCATIONS TO PROVIDE
WEATHER BARRIER BUILDING JOIST SPACE
A COMPLETE VAPOUR BARRIER 5/8" TYPE 'X' DRYWALL AS
PAPER (LAP OVER FLASHING)
HIGH HEEL TRUSS REQUIRED WHEN CANTILEVER 5" HEAT DUCT INSTALL INSULATION AROUND
PROJECTS INTO SIDEYARD -CONTINUOUS IN TOP OF CAVITY RECTANGULAR DUCTS
ROOFING AS PER SPEC. SEALANT OR TO BE AS PER NBC-AE 9.36.3.2(5)
INSULATION STOP ADHESIVE AS
(ENSURE 6" LAP OVER SHEATHING PAPER) SHOWN R12 IB R20 FRICTION RECTANGULAR
6 mil VAPOUR FIT INSULATION DUCT
ROOF EDGE FLASHING FLOOR JOISTS (AS PER LOOSE-LAID BATT INSULATION
(COLOUR TO MATCH FASCIA) BARRIER
MANUFACTURER)
PAPER BEHIND
PREFINISHED 15" WIDE 3/8" OSB RIMBOARD
INSULATION STOP
GUTTER & FASCIA LADDER CAP
6 mil POLY
6 mil VAPOUR FOUNDATION RIGID INSULATION VAPOUR
PREFINISHED SOFFIT

12"-16" LAP
BARRIER LADDER OSB (FASTENED W/ DECK BARRIER
2 LAYER BUILDING AS PER NBC-AE 3.2.3.16 2x6 FROST WALL W/
-CONTINUOUS

6" MIN.
PAPER (16" MIN.) (SLOPE AWAY FROM HOUSE) SCREWS)
SEALANT OR BATT INSULATION
ADHESIVE AS 6 mil POLY VAPOUR PREFINISHED SOFFIT
ENSURE LAP OVER BUILDING PAPER OR TYVEK 2x6" @ 19.2" o.c.
SHOWN BARRIER
INSTALLED
CLADDING AS PER SPEC. BELOW JOISTS
6 mil VAPOUR AIRSPACE SLOPE AS PER LOT GRADING
BARRIER 8" CONCRETE WALL LAP WEATHER
ROOF EAVE PARGING BARRIER OVER 1/2" GD BOARD SECOND FLOOR
6 mil POLY VAPOUR ACOUSTIC SEALANT TO BE USED
PRE-FINISHED METAL
BARRIER CLADDING AS PER SPEC. IN ALL LOCATIONS TO PROVIDE DAMPROOFING
DRIP FLASHING
BATT OVER ATTACHED GARAGE
A COMPLETE VAPOUR BARRIER INSULATION
WEATHER BARRIER BUILDING AIR & VAPOUR SEALING @ FOUNDATION CANTILEVER CLADDING
-CONTINUOUS AS PER SPEC
PAPER (LAP OVER FLASHING) HEADER AS
SEALANT OR
ACOUSTIC SEALANT TO BE USED PER ENG.
ADHESIVE AS TRIM
IN ALL LOCATIONS TO PROVIDE
SHOWN METAL DRIP SPRAY FOAM
A COMPLETE VAPOUR BARRIER
FLASHING
WINDOW AS PER
WINDOW FRAME SPEC./SUPPLIER
FLOOR JOISTS RIMBOARD FLOOR JOISTS w/ CONTINUOUS
(AS PER (AS PER SEALANT BEHIND SHIMS
MANUFACTURER) METAL FLASHING MANUFACTURER) NAILING FLANGE
SEALANT AS REQ'D METAL DRIP JAMB EXTENSION
FLASHING AS PER SPEC.
-CONTINUOUS
ROOF
SEALANT OR
TRUSS
ADHESIVE AS SPRAY FOAM
TRIM
SHOWN
WEATHER BARRIER
ACOUSTIC SEALANT TO BE USED 6 mil POLY 2x6" @19.2" o.c. BUILDING PAPER
VAPOUR INSTALLED (LAP OVER FLASHING) BATT
IN ALL LOCATIONS TO PROVIDE
BARRIER BELOW JOISTS INSULATION
A COMPLETE VAPOUR BARRIER CLADDING
SECOND FLOOR OVER ATTACHED GARAGE SECOND FLOOR OVER ATTACHED GARAGE
AS PER SPEC.

@ GARAGE TRUSS @ HOUSE /GARAGE COMMON WALL WINDOW HEAD & SILL DETAIL
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES ENERGY DETAILS SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 3/4"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-14
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
FRAMED WALL BLENDED RSI CALCULATION FRAMED BLENDED RSI CALCULATION HOUSE/GARAGE BLENDED RSI CALCULATION
-2x6 WALL @24" O.C. (140mm X 0.0085 RSI/mm)
EXTERIOR AIR FILM 0.03 EXTERIOR AIR FILM 0.03 -2x6 WALL @24" O.C. (140mm X 0.0085 RSI/mm)
EXTERIOR AIR FILM 0.03
(HOUSE WALLS) -R22 BATT INSULATION (140mm - RSI 3.87) TALL WALL -2x6 WALL @12" O.C. (140mm X 0.0085 RSI/mm) COMMON WALL(PROTECTED) -R24 BATT INSULATION (140mm - RSI 4.23)
-SPRAY-APPLIED INSULATION (125mm - RSI 4.5)
1.5" EXT. FOAM ACRYLIC STUCCO 1.1 1.5" EXT. FOAM ACRYLIC STUCCO 1.1 GYPSUM (12.7mm) 0.08
EXTERIOR AIR FILM
EXTERIOR AIR FILM 100 100 100
RSI =
%AREA OF CAVITY
BUILDING PAPER 0.00 CLADDING AS PER SPEC. RSI =
%AREA OF CAVITY
BUILDING PAPER 0.00 RSI =
%AREA OF CAVITY
OSB (9.5mm) 0.093
CLADDING AS PER SPEC. ( % AREA OF FRAMING
RSLF ) (
+
RSIC ) WEATHER BARRIER
( % AREA OF FRAMING
RSLF ) ( +
RSIC ) EXTERIOR AIR FILM
( % AREA OF FRAMING
RSLF ) (
+
RSIC )
WEATHER BARRIER OSB (9.5mm) 0.093 BUILDING PAPER (LAP OSB (9.5mm) 0.093 BLENDED RSI FROM CALCULATION 2.79961
100
OVER FLASHING)
100 GYPSUM BOARD (12.7mm) 100
BUILDING PAPER (LAP RSI = RSI = RSI =
80 75.5 80
OVER FLASHING) ( 20
140 X 0.0085 ) (+
3.87 ) BLENDED RSI FROM CALCULATION 2.66819
OSB (9.5mm) ( 24.5
140 X 0.0085 ) ( +
4.5 ) BLENDED RSI FROM CALCULATION 2.67623
OSB (9.5mm)
( 20
140 X 0.0085 ) (+
4.23 ) VAPOUR BARRIER 0.00
WALL SHEATHING
100
VAPOUR BARRIER 0.00 2x6 WALL (140mm) 100 VAPOUR BARRIER 0.00 2x6 WALL (140mm) 100
GYPSUM (12.7mm) 0.08
2x6 WALL (140mm) RSI = RSI = RSI =
75.5

R22 BATT INSULATION


( 20
1.19 ) (+
80
3.87 ) GYPSUM (12.7mm) 0.08
SPRAY-APPLIED
INSULATION (125mm)
( 24.5
1.19 ) ( +
4.5 ) GYPSUM (12.7mm) 0.08 R24 BATT INSULATION ( 20
1.19 ) (+
80
4.23 ) INTERIOR FILM 0.12
(140mm)
(140mm)
6 mil POLY VAPOUR 100 6 mil POLY VAPOUR
100 INTERIOR FILM 0.12 RSI = INTERIOR AIR FILM 0.12 100
6 mil POLY VAPOUR RSI = BARRIER BARRIER RSI =
BARRIER ( 16.80672 ) (+ 20.67183 ) GYPSUM BOARD (12.7mm)
( 20.58824 ) ( + 16.77777 ) ( 16.80672 ) (+ 18.91253 )
GYPSUM BOARD (12.7mm)
GYPSUM BOARD (12.7mm)
100 100 100
RSI = INTERIOR AIR FILM RSI =
37.36601
RSI =
37.47856 INTERIOR AIR FILM 35.71925
INTERIOR AIR FILM
RSI = 2.66819 RSIEFF 4.09 RSI = 2.67623 RSIEFF 4.10 RSI = 2.79961 RSIEFF 3.20

FOUNDATION WALL BLENDED RSI CALCULATION EXTERIOR AIR FILM 0.03 FOUNDATION WALL BLENDED RSI CALCULATION EARTH 0.00
-2x6 WALL @24" O.C. (140mm X 0.0085 RSI/mm) - 2x6 WALL @ 24" O.C. (140mm X 0.0085 RSI/mm)
(ABOVE GRADE) -R24 BATT INSULATION (152mm - RSI 4.23)
(BELOW GRADE) - R24 BATT INSULATION (152mm - RSI 4.23)
PARGING (4.8mm) 0.00432 NORMAL DENSITY CONCRETE (0.0004/mm) 0.08128
100 100
EXTERIOR AIR FILM RSI = DAMPPROOFING 0.00 RSI = AIR CAVITY (12.7mm) 0.00
%AREA OF CAVITY
PARGING ( % AREA OF FRAMING
RSLF ) ( +
RSIC ) EARTH ( % AREA OF FRAMING
RSIF ) ( +
% AREA OF CAVITY
RSIC )
NORMAL DENSITY CONCRETE (0.0004/mm) 0.08128 BLENDED RSI FROM CALCULATION 3.17543
DAMPPROOFING 100 DAMPPROOFING 100
RSI = RSI =
NORMAL DENSITY 87
CONCRETE (203mm) ( 13
140 X 0.0085 ) ( +
4.23 ) AIR CAVITY (12.7mm) 0.00 NORMAL DENSITY CONCRETE ( 13
140 X 0.0085
) ( +
87
4.23 ) VAPOUR BARRIER 0.00
(203mm)
AIR CAVITY (12.7mm)
100
BLENDED RSI FROM CALCULATION 3.17543 100
GYPSUM (12.7mm) 0.08
RSI = AIR CAVITY (12.7mm) RSI =
87 87
R24 BATT INSULATION
(152mm)
( 13
1.19 ) ( +
4.23 ) VAPOUR BARRIER 0.00 R24 BATT INSULATION (152mm)
( 13
1.19 ) ( +
4.23 ) INTERIOR AIR FILM 0.12

2x6 WALL (140mm) 100


RSI = GYPSUM (12.7mm) 0.08 2x6 WALL (140mm) RSI = 100

6 mil POLY VAPOUR ( 10.92437 ) ( + 20.56738 ) 6 mil POLY VAPOUR BARRIER


( 10.92437 ) (
+ 20.56738 )
BARRIER INTERIOR AIR FILM 0.12
100
GYPSUM BOARD (12.7mm) RSI = GYPSUM BOARD (12.7mm) RSI =
100
31.49175
INTERIOR AIR FILM 31.49175

INTERIOR AIR FILM


RSI = 3.17543 RSIEFF 3.49 RSI = 3.17543 RSIEFF 3.46

EXTERIOR WALL @ RIM JOIST EXTERIOR AIR FILM 0.03


EXTERIOR WALL @ RIM JOIST BLENDED RSI CALCULATION EXTERIOR AIR FILM 0.03 FLAT CEILING/ATTIC BLENDED RSI CALCULATION EXTERIOR AIR FILM 0.03
-PARALLEL TO FLOOR JOISTS -PERPENDICULAR TO JOISTS - TJI JOISTS @ 19.2" o.c. -2x6 JOISTS @ 19.2" o.c.
- R20 BATT INSULATION (152mm - RSI 3.52) (FINISHED BELOW -R40 BATT INSULATION (279mm - RSI 7.04)
1.5" EXT. FOAM ACRYLIC STUCCO 1.1 1.5" EXT. FOAM ACRYLIC STUCCO 1.1 BLENDED RSI CALCULATION 6.13431
EXTERIOR AIR FILM ROOF/DECKING AS PER 100
100
RSI = MANUFACTURER RSI =
VAPOUR BARRIER 0.00
BUILDING PAPER 0.00 BUILDING PAPER 0.00 %AREA OF CAVITY
CLADDING AS PER SPEC. EXTERIOR AIR FILM ( % AREA OF FRAMING
RSLF ) (
+
%AREA OF CAVITY
RSIC ) EXTERIOR AIR FILM ( % AREA OF FRAMING
RSLF ) ( +
RSIC )
WEATHER BARRIER BUILDING
GYPSUM (12.7mm) 0.08
RIM JOIST (31.8mm X 0.0085 RSI/mm) 0.2703 CLADDING AS PER SPEC. 100 RIM JOIST (31.8mm X 0.0085 RSI/mm) 0.2703 100
PAPER (LAP OVER FLASHING) RSI = RSI =
92.5 92.5

R20 BATT INSULATION (152mm) 3.52


WEATHER BARRIER BUILDING
PAPER (LAP OVER FLASHING)
( 7.5
152 X 0.0085 ) (
+
3.52 ) BLENDED RSI FROM CALCULATION 3.11688 ( 7.5
279 X 0.0085 ) ( +
7.04 ) INTERIOR AIR FILM 0.12
RIM JOIST (31.8mm) R40 BATT INSULATION
100 100
RSI = RSI =
VAPOUR BARRIER 0.00 VAPOUR BARRIER 0.00 6 mil POLY VAPOUR 92.5
R20 BATT INSULATION (152mm)
RIM JOIST (31.8mm)
( 7.5
1.292 ) (
+
92.5
3.52 ) BARRIER ( 7.5
2.3715 ) (
+
7.04 )
6 mil POLY VAPOUR BARRIER FLOOR JOISTS 100 100
INTERIOR AIR FILM 0.12 R20 BATT INSULATION (152mm) RSI = INTERIOR AIR FILM 0.12 GYPSUM BOARD (12.7mm) RSI =
(AS PER
MANUFACTURER) ( 5.80495 ) (
+ 26.27841 ) INTERIOR AIR FILM
( 3.16256 ) (
+ 13.13920 )
INTERIOR AIR FILM RSIEFF 5.04 6 mil POLY VAPOUR BARRIER
100 100
RSI = RSI =
32.08336 16.30176
INTERIOR AIR FILM

RSI = 3.11688 RSIEFF 4.64 RSI = 6.13431 RSIEFF 6.36

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES RSI CALCULATIONS SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 1/2"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-15
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K
CANTILEVERED FLOOR BLENDED RSI CALCULATION EXTERIOR AIR FILM 0.03 CANTILEVERED FRAMED BLENDED RSI CALCULATION EXTERIOR AIR FILM 0.03 WALK-OUT FRAMING WALL BLENDED RSI CALCULATION EXTERIOR AIR FILM 0.03
- TJI JOISTS @ 19.2" o.c. -2x6 WALL @16" O.C. (140mm X 0.0085 RSI/mm)
(UNFINISHED BELOW) - R20 BATT INSULATION (152 mm - RSI 3.52)
WALL -2x6 WALL @24" O.C. (140mm X 0.0085 RSI/mm)
-R22 BATT INSULATION (140mm - RSI 3.87)
-R24 BATT INSULATION (140mm - RSI 3.87)
PREFINISHED METAL SOFFIT 0.00 1.5" EXT. FOAM ACRYLIC STUCCO 1.1 EXTERIOR AIR FILM 1.5" EXT. FOAM ACRYLIC STUCCO 1.1
CLADDING AS PER SPEC.
100 100 100
RSI = BUILDING PAPER 0.00 EXTERIOR AIR FILM RSI = BUILDING PAPER 0.00 XPS RIGID INSULATION RSI = XPS RIGID INSULATION (50.8mm) 1.30
%AREA OF CAVITY %AREA OF CAVITY
( % AREA OF FRAMING
RSIF ) ( +
% AREA OF CAVITY
RSIC ) CLADDING AS PER SPEC. ( % AREA OF FRAMING
RSLF ) (
+
RSIC ) (50.8mm)
( % AREA OF FRAMING
RSLF ) (
+
RSIC )
OSB (9.5mm) 0.093 OSB (9.5mm) 0.093 WEATHER BARRIER BUILDING PAPER 0.00
WEATHER BARRIER 100 BUILDING PAPER (LAP 100
100
RSI = BUILDING PAPER (LAP RSI = OVER FLASHING) RSI =
80 77
INTERIOR AIR FILM ( 7.5
152 X 0.0085
) ( +
92.5
3.52 ) 2" EXTRUDED POLYSTYRENE (50mm) 1.68 OVER FLASHING) ( 20
140 X 0.0085 ) (+
3.87 ) BLENDED RSI FROM CALCULATION 2.66819 ( 23
140 X 0.0085 ) ( +
3.87 ) OSB (9.5mm) 0.093
FLOOR JOISTS (AS PER WALL SHEATHING
6 mil POLY VAPOUR WALL SHEATHING
MANUFACTURER) BLENDED RSI CALCULATION 3.11688 VAPOUR BARRIER 0.00 2x6 WALL (140mm) BLENDED RSI FROM CALCULATION 2.54944
BARRIER 100
2x6 WALL (140mm) 100 100
RSI = RSI = RSI =
R20 BATT INSULATION 92.5 80 R22 BATT INSULATION 77
(152mm) ( 7.5
1.292 ) ( +
3.52 ) VAPOUR BARRIER 0.00 R24 BATT INSULATION ( 20
1.19 ) (+
3.87 ) GYPSUM - TYPE "X" (15.9mm) 0.09699 (140mm) ( 23
1.19 ) ( +
3.87 ) VAPOUR BARRIER 0.00
EXTRUDED POLYSTYRENE (140mm)
6 mil POLY VAPOUR
WALL SHEATHING RSI =
100 INTERIOR AIR FILM 0.16 6 mil POLY VAPOUR 100 INTERIOR AIR FILM 0.12 BARRIER 100 GYPSUM (12.7mm) 0.08
BARRIER RSI = RSI =

BUILDING PAPER
( 5.80495 ) (
+ 26.27841 ) TYPE "X" GYPSUM BOARD ( 16.80672 ) (+ 20.67183 ) GYPSUM BOARD (12.7mm) ( 19.32773 ) ( + 19.89664 )
(15.9mm) INTERIOR AIR FILM 0.12
PREFINISHED METAL SOFFIT 100 100 INTERIOR AIR FILM 100
RSI = INTERIOR AIR FILM RSI = RSI =
32.08336 37.47856 39.22437
EXTERIOR AIR FILM

RSI = 3.11688 RSIEFF 5.08 RSI = 2.66819 RSIEFF 4.11 RSI = 2.54944 RSIEFF 5.27

WALKOUT FOUNDATION WALL


(UNHEATED FLOOR ABOVE CEILING / ATTIC (HOUSE ONLY) BLENDED RSI CALCULATION PROTECTED WARM FLOOR BLENDED RSI CALCULATION EXTERIOR AIR FILM 0.03
EXTERIOR AIR FILM 0.03
FROST LINE) -2x4 BOTTOM CHORD (89mm X 0.0085 RSI/mm)
(OVER UNCONDITIONED SPACE) -2x6 JOISTS @ 19.2" o.c.
-BLOW-IN INSULATION (89mm X 0.025/mm) -R20 BATT INSULATION (140mm - RSI 3.34)
13.5" BLOWN-IN INSUL. GYPSUM CD BOARD 0.12
EARTH 0.00 8.57
100
(342.9mm X 0.025/mm) 100 (12.7mm X 0.0063)
EXTERIOR AIR FILM RSI =
%AREA OF CAVITY
PARGING (4.8mm) 0.00432 BLOWN -IN (CELLULOSE)
(342.9mm)
RSI =

( % AREA OF FRAMING
) (
+
%AREA OF CAVITY
) BLENDED RSI FROM ( % AREA OF FRAMING
RSLF ) ( +
RSIC ) BLENDED RSI CALCULATION 2.76542
RSLF RSIC 1.83047
2x4 BOTTOM CHORD 100 CALCULATION 100
EXTRUDED POLYSTYRENE (63.5mm X 0.0336) 2.1336 (89mm) RSI = RSI =
88.5
TOP LAYER OF R12 BATT 2.11
EARTH BLOWN-IN (CELLULOSE)
( 11
89 x 0.0085 ) ( +
89
89 x 0.025 ) VAPOUR BARRIER 0.00 INTERIOR AIR FILM ( 11.5
140 X 0.0085 ) ( +
3.34 ) INSULATION
PARGING (4.8mm) NORMAL DENSITY CONCRETE (0.0004/mm) 0.08128 (89mm)
100 6 mil POLY VAPOUR 100
2 1/2" EXTRUDED RSI = GYPSUM (12.7mm) 0.08 BARRIER
RSI = VAPOUR BARRIER 0.00
6 mil POLY VAPOUR 88.5
POLYSTYRENE
DOWN TO FOOTING RSIEFF 2.22 BARRIER ( 11
0.7565 ) ( +
89
2.22 ) ( 11.5
1.19 ) ( +
3.34 )
(63.5mm) INTERIOR AIR FILM 0.11 R12 FRICTION FIT BATT 100
INTERIOR AIR FILM 0.16
100
RSI = INSULATION (89mm) RSI =
DAMPPROOFING
NORMAL DENSITY
GYPSUM BOARD
(12.7mm) ( 14.54065 ) ( + 40.09 ) R20 FRICTION FIT BATT
( 9.66387 ) ( + 26.49701 )
CONCRETE
100 INSULATION (140mm) 100
(203mm) RSI = RSI =
INTERIOR AIR FILM 54.63065 36.16087
GYPSUM BOARD (12.7mm)

RSI = 1.83047 RSIEFF 10.62 EXTERIOR AIR FILM


RSI = 2.76542 RSIEFF 5.19

WALL @ INTERIOR OUTLET WALL @ EXTERIOR OUTLET


WALL @ INTERIOR OUTLET 0.03
WALL @ EXTERIOR OUTLET EXTERIOR AIR FILM 0.03
BOX (HOUSE/GARAGE 0.03 BOX (HOUSE/GARAGE 0.03
EXTERIOR AIR FILM EXTERIOR AIR FILM EXTERIOR AIR FILM
BOX (HOUSE WALLS) BOX (HOUSE WALLS) COMMON WALL) COMMON WALL)
EXTERIOR AIR FILM
1.5" EXT. FOAM ACRYLIC STUCCO 1.1 OUTLET BOX 0.00 GYPSUM (12.7mm) 0.08 OUTLET BOX 0.00
EXTERIOR AIR FILM
CLADDING AS PER SPEC. EXTERIOR AIR FILM
BUILDING PAPER 0.00 CLADDING AS PER SPEC. POLY HAT 0.00 EXTERIOR AIR FILM OSB (9.5mm) 0.093 POLY HAT 0.00
WEATHER BARRIER GYPSUM BOARD (12.7mm)
BUILDING PAPER (LAP VAPOUR BARRIER GYPSUM BOARD (12.7mm)
OVER FLASHING) OSB (9.5mm) 0.093 BATT INSULATION (89mm X 0.02865 RSI/mm) 2.55 BATT INSULATION (89mm X 0.02865 RSI/mm) 2.55 BATT INSULATION (89mm X 0.02865 RSI/mm) 2.55
WALL SHEATHING OSB (9.5mm)
WALL SHEATHING OSB (9.5mm)
BATT INSULATION (89mm X 0.02865 RSI/mm) 2.55 OUTLET BOX INSET 51mm INTO VAPOUR BARRIER 0.00 POLY HAT 0.00 OUTLET BOX INSET 51mm INTO VAPOUR BARRIER 0.00
OUTLET BOX INSET 51mm INTO OUTLET BOX INSET 51mm INTO 2x6 WALL (89mm INSULTATION
2x6 WALL (89mm INSULTATION 2x6 WALL (89mm INSULTATION
2x6 WALL (89mm INSULTATION REMAINING BEHIND BOX)
REMAINING BEHIND BOX) REMAINING BEHIND BOX)
REMAINING BEHIND BOX) POLY HAT 0.00 GYPSUM (12.7mm) 0.08 OUTLET BOX 0.00 GYPSUM (12.7mm) 0.08
R22 BATT INSULATION
R22 BATT INSULATION R22 BATT INSULATION R22 BATT INSULATION (140mm)
(140mm) OUTLET BOX 0.00 (140mm) INTERIOR AIR FILM 0.12 (140mm) INTERIOR AIR FILM 0.12 INTERIOR AIR FILM 0.12
6 mil POLY VAPOUR
6 mil POLY VAPOUR 6 mil POLY VAPOUR 6 mil POLY VAPOUR BARRIER
BARRIER INTERIOR AIR FILM 0.12 BARRIER BARRIER
GYPSUM BOARD (12.7mm) GYPSUM BOARD (12.7mm) GYPSUM BOARD (12.7mm)
GYPSUM BOARD (12.7mm)
RSIEFF 2.78
INTERIOR AIR FILM INTERIOR AIR FILM INTERIOR AIR FILM
INTERIOR AIR FILM
RSIEFF 3.89 RSIEFF 2.78 RSIEFF 2.87

CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED: 15-07-2024 JOB #: 4311
MAIN FLOOR : 1745 SQ. FT. DESIGNER: RANGARAJ.K
ROYAL VILLA HOMES RSI CALCULATIONS SECOND FLOOR : 1946 SQ. FT. LOT: 27 BLOCK: 07 PLAN: 232 0809
DATE MODIFIED
002 13-09-2024 , SHAMILA.R
SHEET NO.
www.protechhomedesign.com PHONE: 780 965 5819 SCALE 1/2"=1' APPLICABLE ON 11"X17" PAPER TOTAL FLOOR AREA: 3691 SQ. FT.
P-16
[email protected] 003 19-09-2024 , RANGARAJ.K
1324 Windermere Way SW, Edmonton, AB T6W 0P1 MODEL STYLE GARAGE : 705 SQ. FT. 1902 59 AVE NE 004 23-09-2024 , RANGARAJ.K
NISKU , ALBERTA 005 02-10-2024 , RANGARAJ.K
phone: 780-970-1938 CUSTOM MODERN PAIRIE FOUNDATION CONCRETE SLAB: 1648 SQ. FT. 006 26-11-2024 , RANGARAJ.K