1. Monitor This function makes it possible to read the data in the DOC PCB. At the same time, it
can read and write the data in the DES PCB.
1.1 Monitor Screen Description
1) The initial screen of the monitor

When the main power is turned on, the following screen will be displayed on the LCD:

2) 1 row: running mode, current floor, load capacity and elevator running speed.
a.ACD=27
(column 1~6): operation mode code
Example: 27*automatic operation, 4*inspection operation, ...
※Refer to the operation mode description table.
b.01FL (columns 8 ~ 11): current floor
c. 00% (column 13 ~ 16): When stopping, it displays the current load (%) of the elevator.

3) Line 2: When a fault occurs, it will display the highest fault code, operating conditions, elevator
running direction and main output signal status.
a. E000 (columns 2~4): the highest level of fault code that occurred. (TCD code number. 1~255)