SCHOMBURG GmbH & Co.

KG
Aquafinstrasse 2–8
D-32760 Detmold (Germany)
phone +49-5231-953-00
fax +49-5231-953-108
email [email protected]
www.schomburg.com Technical Data Sheet

ASOCRET-VK100 Art. no. 2 06417


Highly fluid mineral-based grouting mortar

Technical Data:
Particle size: 0–4.0 mm
Wet density of
SCHOMBURG GmbH & Co. KG
Aquafinstrasse 2–8 fresh mortar*): approx. 2.3 kg/dm3
D-32760 Detmold
16 Consumption: approx. 2.0 kg/dm3
2 06417
DIN EN 1504-6:2006-11 Water demand: approx. 3.5 l /
NPD= „No Performance Determinded“

ASOCRET-VK100
Anchoring product 25 kg ASOCRET-VK100
Pull out strength
Chloride ion content
≤ 0.6mm
≤ 0.05%
Pot life*): approx. 60 minutes
Reaction to fire A1
Dangerous substances NPD Slump*): after 5 min. ≥550 mm
after 30 min. ≥450 mm
Expansion rate*): after 24 hrs ≥0.5% by volume
• Mineral-based Shrinkage rate *):
• For interior and exterior application after 28 days approx. 1.4 mm/m
• Chloride free after 90 days approx. 1.9 mm/m
• Highly fluid
Compressive strength*):
• Resistant to frost and de-icing salts
after 24 hrs approx. 50 N/mm2
• Water impermeable
after 28 days approx. 60 N/mm2
after 56 days approx. 70 N/mm2
ASOCRET-VK100 guarantees a strong adhesive bond to
after 90 days approx. 90 N/mm2
concrete subfloors.
Flexural strength *):
after 24 hrs approx. 6 N/mm2
Areas of application: after 28 days approx. 9 N/mm2
ASOCRET-VK100 is used as an adhesive grout for filling after 56 days approx. 10 N/mm2
voids from 20 to 100 mm deep e.g. for the void free after 90 days approx. 11 N/mm2
grouting of: Cleaning: Thoroughly clean tools with
• Kerbstones (e.g. Dresden Combibord) water after use.
• Pre-cast concrete elements Packaging: 25 kg bags.
• Machine foundations, supports etc. Storage: 12 months when stored
• Crane rails cool and dry in the original
unopened packaging. Use
Furthermore for the void free grouting of: opened packaging promptly.
• Recesses and joints in concrete
• Steel inserts and channels in concrete *) These values relate to +23° C and 50% relative humidity.
**) PFT consistency testing tin on non absorbent substrate e.g. PE board, after
• Anchor bolts. 5 minutes. All specified data are indicative values, which are available
from laboratory and site experience.

1/2 21/21
ASOCRET-VK100

Substrate preparation: Mechanical equipment:


The substrate must be load-bearing, sound, have a good Pipe length: max. 40 m
key and be free from materials detrimental to adhesion Pipe size: 25–35 mm
such as e.g. dust etc. Remove all loose or poorly bonded Stator/Rotor: D6-3 z
layers and repair back to a solid base including any Secondary mixer: Rotormix for D pumps
deep voids. Remove laitance layers using suitable Water quantity: approx. 325–350 l/h
means e.g. high pressure washing, grit-blasting or hand Slump PFT consistency test tin: 58 ± 2 cm
scabbling. Pre-wet the substrate so that it is matt damp at
the time ASOCRET-VK100 is applied. Avoid ponding. Casting:
The casting or grouting is carried out exclusively from
Concrete quality: min. C25/30 one side or corner so that displaced air can escape. The
Asphalt subfloors: 0/16 casting process should not be interrupted.
Tensile adhesion For casting procedures in large areas, it is recommended
strength: ≥ 1.5 N/mm2 to begin from the middle where possible.
Hoppers and/or appropriate hoses can be used to
Shuttering: assist the process. Firstly cast around anchoring recesses
The shuttering used must be securely fixed and sealed as (approx. up to the top of the anchor recess) and then
necessary. cast around machinery plates.

Product preparation: Important advice:


Hand application: • Protect areas that are not to be treated from the effects
For each 25 kg ASOCRET-VK100, approx. 3.5 l of of ASOCRET-VK100.
water is required. The use of a compulsory mixer is • With each grouting operation ensure that the slump
recommended for mixing. Initially place approx. 3.2 l value is adjusted as above before starting the pour.
water and 25 kg ASOCRET-VK100 in the mixer and mix Furthermore each grouting operation must be carried
for approx. 3 minutes. Then add the remaining water out continuously and without interruption. Ensure there
and mix for a further 2 minutes until homogenous and is a continuous flow of material.
free from lumps. The mixture is then ready for immediate • Protect exposed areas from wind and draughts. Cover
pouring. with polythene to prevent early water evaporation.
• Lower temperatures and cold gauging water delay
Mechanical application: the strength development and decrease the flow
ASOCRET-VK100 can be prepared in all conventional rate. Higher temperatures accelerate the strength
conveyor pumps or continuous mixing pumps (e.g. development.
PFT G4 , PFT, Iphofen). To ensure correct operation
and trouble free service with the equipment, refer to the Please observe a current safety data sheet.
relevant manufacturer’s instructions. GISCODE: ZP1

The rights of the buyer with regard to the quality of our materials are based on our terms and conditions of sale and delivery. Our technical advice team will be happy to advise you in the case
of requirements that exceed the scope of the application described here. In order to be binding, a legally binding written confirmation is required. The product description does not release
the user from a duty of care. Apply to a test area in the event of uncertainty. This version becomes invalid in the event of a new version being issued.

2/2 SF/CoS/TM/KKa 21/21