HJM AVA-H ENG-seco Rev.1 20-09-2022
HJM AVA-H ENG-seco Rev.1 20-09-2022
Heater
Réf: AVA H
Mod: AVA H 1000, AVA H 1500 & AVA H 2000
INSTALLATION
• During the first use and for a few minutes, could occur smells and noise due to
the dilatation of some internal parts. This is normal, so you must provide
adequate ventilation. The smells are momentary and quickly will dissipate.
• For greater efficiency, make sure to calculate the power or the number of
elements of the apparatus according to the surface of the room. We recommend
contacting your dealer performing this calculation.
• Fix the radiator to a firm wall and make sure it is well-levelled, in a room with no
furniture and no objects avoiding around.
• Avoid installing the appliance in corners.
• We advise against installing the appliance under the windows, because it is
favoring the heat loss.
• The radiator must be away, at a minimum distanceof15cmfrom any combustible
material, curtains, furniture, chairs, etc.(Fig. 1).
Fig.1 Fig.2
The radiator is equipped with a support, three lag screws and their corresponding
plugs, a fixing screw and a plastic levelling plug.
- 1º Fix the bracket to the wall, respecting the height indicated. Fig 1
- 2º Attach the plastic dowel (A) to the back of the unit and to the lower part of the
unit.
- 3º Hang and centre the appliance on the bracket.
- 4º Finally, fix with the screw at the junction of the wall bracket and the radiator.
This radiator is equipped with various functions and operating modes that the user can select
using the “MODE” button.
The operating modes are: Pilot Wire, Comfort, Economy, Anti-Frost, Holidays, Timer, Turbo,
Eco and Off (Stand-by). These are their related icons:
• Pilot Wire Mode: The thermostat’s functions are controlled through a signal
received from the “Pilot Wire” unit. FOR USE IN FRANCE ONLY
• Comfort Mode: The thermostat keeps the room temperature at the value
established by the user.
• Economy Mode: The thermostat keeps the room temperature below the
configured Comfort value.
• Holiday Mode: The radiator enters the “Anti-frost” mode for the period of time
established by the user.
• Economy Mode set at 17⁰C: The device keeps the room temperature stable
at 17 ° C
• Off (Stand-by) Mode: In this mode the electric resistance is not being fed and
the light at the back of the screen goes off. However, the thermostat is operating.
• Safety for children: This function reduces the radiator’s surface temperature.
• Consumption meter: This function lets us know the consumption data for
different periods, in kWh.
1. ON / OFF (STAND-BY)
Press the On/Off (Stand-by) button to turn the radiator on or to set the off/stand-by
mode.
If the off/stand-by mode is activated, the corresponding icon will appear on the screen
and there will be two 0.5 second bleeps and the time will be shown.
When the device is turned on, there will be a one second bleep and the icon will
disappear.
PILOT WIRE Mode: (FOR USE IN FRANCE ONLY). In this mode, the radiator is controlled
by a unit with this type of system.
In order to activate it, follow these steps:
1. Press the “Mode" button several times until the icon appears on the
screen. From this moment onwards, the radiator’s operating mode is the one
determined by the unit.
COMFORT Mode: This is the radiator’s standard operating mode to maintain the user’s
desired temperature.
In order to activate it, follow these steps:
1. Press the “Mode" button several times until the icon appears on the
screen.
2. Select the desired temperature using the and buttons. The minimum value
that can be programmed is equal to the value of the temperature programmed in
economy mode plus 0.5°C. The maximum value is 32°C.
ECONOMY Mode: Selecting this mode, the radiator maintains the room temperature at
the one selected for it.
In order to activate it, follow these steps:
1. Press the “Mode" button several times until the icon appears on the screen.
2. Select the desired temperature using the and buttons. The maximum value
that can be programmed is equal to the value of the COMFORT temperature less
0.5°C. The minimum value is 7°C.
NOTE: The COMFORT and ECONOMY temperatures are the programme’s determining
values. It is not possible to select a temperature value for the ECONOMY mode superior
to the COMFORT temperature, as the electronic thermostat does not allow it. When
operating, it is possible to change the temperature easily by pressing the and
buttons.
activate it, press the “Mode" button several times until the icon appears on
the screen.
HOLIDAY MODE: Selecting this mode, the radiator enters the ANTI-FROST mode for the
period of time established by the user.
In order to activate it, follow these steps:
1. Press the “Mode" button several times until the icon appears on the screen.
2. Using the and buttons it is possible to select the holiday period duration,
from 12 hours to 40 days, with an increase of one hour 12 to 24 and with an increase
of one day from 24 hours.
TIMER MODE: In this mode, the room temperature is maintained at the COMFORT or
ECONOMY temperature depending on the programmes established for the different
time intervals during the day (P1, P2 or P3).
In order to activate it, follow these steps:
1. Press the “Mode" button several times until the icon appears on the
screen.
2. Press the TIMER button to select one of the pre-established factory
programmes (P1 and P2 ) or the programme that is configurable by the
user (P3 ).
For configurable programming P3, please look at section “4. PROGRAMMING” in this
manual.
The pre-established P1 and P2 programmes are:
1. Press the “Mode" button several times until the icon appears on the
screen.
2. Pressing the and buttons it is possible to select the TURBO/BOOST period
duration from 5 to 120 minutes. When this function is activated, the radiator
operates at its maximum power, ensuring that the room temperature does not
exceed 32°C. When the programmed time (indicated by the countdown on the
screen) finishes, the radiator returns to the previously established mode.
ECONOMY MODE 17⁰C: Activating this mode the radiator operates at a pre-
established, unchangeable temperature of 17°C. This function allows for lower
consumption when, for example, the room or the house is empty for an indefinite
period of time.
OPEN WINDOW DETECTION: The radiator is able to detect if a window has been opened
through a sudden drop in temperature (5°C in a maximum of 30 minutes). If this
happens, the device disconnects for 30 minutes so as to, later on, operate again at the
previously established mode if it detects continuous increases in temperature of one
degree (because, for example, the window has been closed). If this is not the case, the
device will remain disconnected for an additional period of 30 minutes.
When the open window detection is activated, the corresponding symbol will appear
intermittently on the screen (except in off/stand-by mode). When it is deactivated, the
symbol disappears.
In order to activate this function, please look at section “4. PROGRAMMING”.
CHILD PROTECTION: When this function is activated, the temperature on the front part
of the radiator is lowered so that it is safe when children are present. Moreover, this
function means that the same radiator can be used in rooms smaller than the one it is
installed in without significant changes in room temperature.
When this function is activated, the power level that the radiator operates at is the one
established by the user (40% - 50% - 60%).
In order to activate this function, please look at section “4. PROGRAMMING”.
ASC (ADAPTIVE TEMPERATURE CONTROL): When this function is activated, the device
connects before the time established in the programming (maximum 2 hours
beforehand) to ensure that the room is at the programmed temperature at the
established time.
When this function is activated, the corresponding icon appears on the screen (except
in off/stand-by mode).
In order to activate this function, please look at section “4. PROGRAMMING”.
BLOCK FUNCTION: It is possible to block the radiator to prevent children from using it
improperly or, for example, in a public space.
In order to block/unblock the buttons, press the “Mode” button and keep in pressed
down for 3 seconds, until the icon appears (blocked) or disappears (unblocked).
This operation only needs to be done the first time and then it will stay saved; it is not
necessary to repeat it every time you wish to consult consumption.
Now you can read the consumption for various periods of time in the following way:
= current day
= previous day
= current week
= previous week
= current month
= previous month
= current year
+ = previous year
+ = total
CONSUMPTION INDICATOR: When the room temperature falls below the configured
temperature, the radiator’s thermostat feeds the resistance and the symbol lights
upon the screen, with which it is consuming energy. As soon as the room temperature
reaches the selected temperature, the thermostat stops feeding the resistance and the
icon disappears from the screen, as it is no longer consuming energy.
IMPORTANT NOTE: If “ALL” appears on the screen then the temperature sensor is broken
or damaged and the radiator does not work. Please contact our technical service.
4. PROGRAMMING
DAY AND TIME PROGRAMMING
You can configure your own operating programme (P3) for each day of the week by following
these steps:
If the radiator is not installed in the optimum location to suitably detect the room
temperature (for example: it is installed on a cold wall or there are draughts…) the
measured room temperature may be different from the real temperature. In order to
achieve maximum efficiency, it is recommendable to eliminate this temperature
difference.
To do so, follow these steps:
CHILD PROTECTION
MAINTENANCE
Your radiator requires no regular maintenance, however, to ensure its good
operation:
Always disconnect the device from the mains before performing any cleaning or
maintenance operation.
To avoid any risk of electrical shock, clean the unit with a soft, damp cloth to wipe the
outside of the radiator and remove dust and dirt cloth.
Do not use detergent, solvent, abrasive products or any other chemical product to
clean the radiator.
Product:
Heater
Trademark:
Models: AVA H
AVA H1000.
Types: AVA H1500.
AVA H2000.
(1) Explanation of code "Lot & Serial No.": Lot = Mx - YYDDD; where: Mx = Production Line No.; YY = year
(15,16,17...99) and DDD = jour corrélative (001,..., 365).
Serial No. = XXX (001,..., 999).
We:
HERMANOS JULIÁN M., S.L.
Head Office: Esposos Curie, 44 / Factory: Gutenberg,91-93
Polígono Industrial “Los Villares”. 37184 Villares de la Reina . Salamanca . España
Tf.+34 923 222 277 +34 923 222 282 . Fax +34 923 223 397
http://www.hjm.es
Hereby declare, that the following equipment complies with all the essential requirements for health and safety of
European Directives.
2014/30/UE EMC DIRECTIVE 2014/35/UE LV DIRECTIVE
2011/65/UE RoHS DIRECTIVE 2009/125/EC (ErP Directive)
With reference to the application of the followinf standards:
2014/30/UE EMC DIRECTIVE EN 55014-1:2006 +A1:2009 +A2:2011
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55014-2:1997 +AC: 1997 +A1:2001 +A2:2008
EN 61000-4-2:2009
EN 61000-4-3:2006 +A1:2008 +A2:2010
EN 61000-4-4:2012
EN 61000-4-5:2006
EN 61000-4-6:2013
EN 61000-4-11:2004
2014/35/UE LV DIRECTIVE EN 60335-2-30:2009 + CORR:2010 +A11:2012
EN 60335-1:2012 +AC:2014 +A11:2014
EN 62233:2008 +CORR:2008
2011/65/UE RoHS DIRECTIVE EN 62321-1:2013
2009/125/EC (ErP Directive) UE 2015/1188
electronic room
temperature control YES
plus week timer
Heat output Other control options (multiple
1500 selections possible)
room temperature
Nominal heat output Pnom 1.5 kW control, with presence NO
detection
Maximum continuous room temperature
Pmax,c 1.5 kW control, with open YES
heat output
window detection
Maximum continuous
Pmax,c 1 kW
heat output
Auxiliary electricity
consumption
η= 40 -10%+0+7+2-0-0 = 39%
Factory: Gutenberg,91-93
Polígono Industrial “Los Villares”
ES-37184 Villares de la Reina . Salamanca . Spain
+34 923 222 277 - +34 923 222 282
Fax: +34 923 223 397
Web: www.hjm.es
ESB-37295664