0% found this document useful (0 votes)
84 views17 pages

STG700 Honeywell

Uploaded by

donydamara4628
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views17 pages

STG700 Honeywell

Uploaded by

donydamara4628
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

SmartLine

Technical Information

STG700 SmartLine Gauge Pressure


Specification 34-ST-03-122, March 2024

Introduction
Part of the SmartLine® family of products, the STG700 and
STG70L are suitable for monitoring, control and data
acquisition featuring piezoresistive sensor technology
combining pressure sensing with on-chip temperature
compensation capabilities providing high accuracy, stability
and performance over a wide range of application
pressures and temperatures. The SmartLine family is also
fully tested and compliant with Experion ® PKS providing
the highest level of compatibility assurance and integration
capabilities. SmartLine easily meets the most demanding
application needs for pressure measurement applications.

Best in Class Features:


• Accuracies up to 0.065% of span.
• Stability up to 0.020% of URL per year for 10
years.
• Automatic temperature compensation. Figure 1 – STG700 Dual Head and Inline Gauge
• Rangeability up to 100:1. Pressure Transmitters feature field-proven
piezoresistive sensor technology
• Response times as fast as 100ms .
• Easy to use and intuitive display capabilities.
• Intuitive External Zero, Span and configuration Span & Range Limits:
capability. URL LRL Min Span
Model
• Comprehensive on-board diagnostic capabilities. psi (bar) psi (bar) psi (bar)

• Integral Dual Seal design for safety based on STG735/STG73S 50 (3.5) -14.7 (-1.0) 0.5 (0.035)
ANSI/NFPA 70-202 and ANSI/ISA 12.27.0. STG745/STG74S 500 (35) -14.7 (-1.0) 5 (0.35)
• Full compliance to SIL 2/3 requirements.
STG775/STG77S 3000 (210) -14.7 (-1.0) 30 (2.1)
• Modular design characteristics.
STG78S 6000 (420) -14.7 (-1.0) 60 (4.2)
• Available with additional 4-year warranty.
STG79S 10000 (690) -14.7 (-1.0) 100 (6.9)

Communications/Output Options:

• HART ® (version 7.0)


2 STG700 Smart Pressure Transmitter

Description Configuration Tools

The SmartLine family pressure transmitters are designed Integral Three Button Configuration Option
Suitable for all electrical and environmental requirements,
around a high performance piezo-resistive sensor. This one
sensor integrates multiple sensors linking process pressure SmartLine offers the ability to configure the transmitter and
measurement with on-board static pressure (GP Models) display via three externally accessible buttons when either
and temperature compensation measurements. display option is selected. Zero/span capabilities are also
optionally available via these buttons with or without
Unique Indication/Display Option
selection of a display option.
Standard LCD Display Features Handheld Configuration
SmartLine transmitters feature two-way communication and
• Modular (may be added or removed in the field).
configuration capability between the operator and the
• Supports HART protocol variant. transmitter. All Honeywell transmitters are designed and
• 0, 90,180, & 270 degree position adjustments. tested for compliance with the offered communication
protocols and are designed to operate with any standards
• Four configurable screens.
compliant handheld configuration device, such as Honeywell
• Standard and custom measurement units available.
Versatilis Configurator.
• Display calculated flow (square root) value in addition
to analog output signal.
Personal Computer Configuration
• 2 Lines 6 digits PV (9.95H x 4.20W mm) 8 Characters. On a personal computer or laptop, Honeywell Field Device
Manager (FDM) Software and FDM Express can be used for
• Write protect Indication.
managing HART device configurations.
• Built-in Basic Device Configuration through Internal or
External Buttons – Range/Engineering Unit/Loop Test
/Loop Calibration/Zero /Span Setting. Modular Design
To help contain maintenance & inventory costs, all ST 700
• Multiple language capabilities (EN, RU).
transmitters are modular in design supporting the user’s
Diagnostics ability to replace meter bodies, standard displays or
SmartLine transmitters all offer digitally accessible electronic modules without affecting overall performance.
diagnostics which aid in providing advanced warning of Each meter body is uniquely characterized to provide in-
possible failure events minimizing unplanned shutdowns, tolerance performance over a wide range of application
providing lower overall operational costs. variations in temperature and pressure.

Modular Features
System Integration
• SmartLine communications protocols all meet the most • Meter body replacement
current published standards for HART. • Add or remove standard displays
• All ST 700 units are Experion tested to provide the
• Add or remove lightning protection (terminal
highest level of compatibility assurance. connection)

With no performance effects, Honeywell’s unique modularity


results in lower inventory needs and lower overall operating
costs.
STG700 Smart Pressure Transmitter 3

Performance Specifications

Reference Accuracy: (conformance to +/-3 Sigma)


Table 1
Reference
Maximum Stability (%
Accuracy1,2
Model URL LRL Min Span Turndown URL/Year for
(% Span)
Ratio 10 years)
Standard
STG735 50 psi (3.5 bar) -14.7 psi (-1.0 bar) 0.5 psi (0.035 bar)
Standard Accuracy

STG73S 50 psi (3.5 bar) -14.7 psi (-1.0 bar) 0.5 psi (0.035 bar)
STG745 500 psi (35 bar) -14.7 psi (-1.0 bar) 5 psi (0.35 bar)
STG74S 500 psi (35 bar) -14.7 psi (-1.0 bar) 5 psi (0.35 bar)
100:1 0.020 0.065
STG775 3000 psi (210 bar) -14.7 psi (-1.0 bar) 30 psi (2.1 bar)
STG77S 3000 psi (210 bar) -14.7 psi (-1.0 bar) 30 psi (2.1 bar)
STG78S 6000 psi (420 bar) -14.7 psi (-1.0 bar) 60 psi (4.2 bar)
STG79S 10000 psi (690 bar) -14.7 psi (-1.0 bar) 100 (6.9 bar)
Zero and span may be set anywhere within the listed (URL/LRL) range limits

Accuracy, Span and Temperature Effect: (Conformance to +/-3 Sigma)

Table 2
Combined Zero & Span
Accuracy1,2
temperature Effect
(% of Span)
(% Span/28oC(50oF))
Reference C
Model URL A B D E
Turndown (see URL units)
STG735 50 psi (3.5 bar) 16.7:1 3 (0.21) 0.070 0.008
Standard Accuracy

STG73S 50 psi (3.5 bar) 8:1 6 (0.42) 0.100 0.015


STG745 500 psi (35 bar) 20:1 25 (1.75) 0.075 0.013
STG74S 500 psi (35 bar) 20:1 0.005 0.060 35 (2.45) 0.100 0.020
STG775 3000 psi (210 bar) 8.5:1 350 (24.5) 0.075 0.013
STG77S 3000 psi (210 bar) 8.5:1 400 (28) 0.100 0.025
STG78S 6000 psi (420 bar) 10:1 600 (42) 0.100 0.070
STG79S 10000 psi (690 bar) 8:1 0.025 0.040 1200 (82.8) 0.200 0.170
Turn Down Effect Temp Effect

±[ 𝐴 + 𝐵 ] 𝑖𝑓 𝑆𝑝𝑎𝑛 ≥ 𝐶
𝑈𝑅𝐿
𝐶 ±[𝐷+𝐸 ( )]
±[ 𝐴 + 𝐵 ( )] 𝑖𝑓 𝑆𝑝𝑎𝑛 < 𝐶 𝑆𝑝𝑎𝑛
𝑆𝑝𝑎𝑛

Total Performance (% of Span):


Total Performance Calculation: = +/- √ (Accuracy)2 + (Temperature Effect)2
Total Performance Examples (for comparison): (standard accuracy, 5:1 Turndown, +/-50oF (28oC) shift)
STG735 @ 10 psi: 0.128% of span STG73S @ 10 psi: 0.187% of span
STG745 @ 100 psi: 0.154% of span STG74S @ 100 psi: 0.210% of span
STG775 @ 600 psi: 0.154 % of span STG77S @ 600 psi: 0.234% of span
STG78S @ 1200 psi: 0.455% of span STG79S @ 2000 psi: 1.052% of span

Typical Calibration Frequency:


Calibration verification is recommended every two (2) years

Notes:
1
. Terminal Based Accuracy - Includes combined effects of linearity, hysteresis, and repeatability. Analog output adds 0 .006% of span.
2
. For zero based spans and reference conditions of: 25oC (77oF) for LRV > = 0 psia, 10 to 55% RH, and 316 Stainless Steel barrier
diaphragm.
4 STG700 Smart Pressure Transmitter

Operating Conditions – All Models


Reference Rated Condition Operative Limits Transportation and
Parameter
Condition Storage
C F C F C F C F
Ambient Temperature1 25±1 77±2 -40 to 85 -40 to 185 -40 to 85 -40 to 185 -55 to 120 -67 to 248
Meter Body Temperature 25±1 77±2 -40 to 110 -40 to 230 -40 to 125 -40 to 257 -55 to 120 -67 to 248
Humidity %RH 10 to 55 0 to 100 0 to 100 0 to 100
Vac. Region – Min. Pressure
mmHg absolute Atmospheric 25 2 (short term) 2
inH2O absolute Atmospheric 13 1 (short term) 2

Supply Voltage 10.8 to 42.4 Vdc at terminals (IS versions limited to 30 VDC)
Load Resistance 0 to 1,440 ohms (as shown in Figure 2)
Maximum Allowable
Working Pressure STG735: 50 psi (3.5 bar) STG73S: 50 psi (3.5 bar)
(MAWP)3, 4 STG745: 500 psi (35 bar) STG74S: 500 psi (35 bar)
(ST700 products are rated to STG775: 3000 psi (210 bar ) STG77S: 3000 psi (210 bar)
Maximum Allowable Working STG78S: 6000 psi (420 bar)
Pressure. MAWP depends on
Approval Agency and STG79S: 10000 psi (690 bar)
transmitter materials of
construction.)
1
LCD Display operating temperature -20C to +70C Storage temperature -30C to 80C.
2
Short term equals 2 hours at 70C (158F).
3
Units can withstand overpressure of 1.5 x MAWP without damage.
4
Consult the factory for MAWP of ST 700 transmitters with CRN approval.
5
Silicone minimum temperature rating is -40C (-40F). CTFE minimum temperature rating is -40C (-40F).

Figure 2 - Supply voltage and loop resistance chart & calculations


STG700 Smart Pressure Transmitter 5

Performance Under Rated Conditions – All Models


Parameter Description
Analog Output Two-wire, 4 to 20 mA
Digital Communications: HART7
HART Output Failure Modes Honeywell Standard NAMUR NE 43 Compliance
Normal Limits: 3.8 – 20.8 mA 3.8 – 20.5 mA
Failure Mode: ≤ 3.6 mA and ≥ 21.0 mA ≤ 3.6 mA and ≥ 21.0 mA
Supply Voltage Effect 0.005% span per volt.
Transmitter Turn on Time
(includes power up & test 2.5 seconds
algorithms)
Response Time
100ms
(delay + time constant)
Damping Time Constant Adjustable from 0 to 32 seconds in 0.1 increments. Default Value: 0.5 seconds
Vibration Effect: Less than +/- 0.1% of URL w/o damping
Per IEC60770-1 field or pipeline, high vibration level (10-2000Hz: 0.21
displacement/3g max acceleration)
Electromagnetic Compatibility IEC 61326-3-1
Lightning Protection Option Leakage Current: 10uA max @ 42.4VDC 93C
Impulse rating:
8/20us 5000A (>10 strikes) 10000A (1 strike min.)
10/1000us 200A (> 300 strikes)

Materials Specifications (see model selection guide for availability/restrictions with various models)
Parameter Description
Barrier Diaphragms Material STG700 Dual Head: 316L SS, Hastelloy® C-2762
STG700 Inline: 316L SS, Hastelloy® C-2762
Process Head Material STG700 Dual Head: Carbon Steel (Zinc Plated)5, 316 SS4, Hastelloy® C-2766
STG700 Inline: 316L SS, Hastelloy® C-2766
Vent/Drain Valves & Plugs 1 STG700 Dual Head:316 SS4, Hastelloy® C-2762
STG700 Inline: N/A
Head Gaskets STG700 Dual Head: Glass-filled PTFE standard. Viton® and graphite are optional.
STG700 Inline: N/A
STG700 Dual Head: Carbon Steel (Zinc plated) standard. Options include 316 SS,
NACE A286 SS bolts and nuts or NACE A286 SS bolts and 304 SS nuts, and Super
Meter Body Bolting
Duplex.
STG700 Inline: N/A
Mounting Bracket Carbon Steel (Zinc-plated) or 304 or 316 Stainless Steel, See Figures 3 & 4
Fill Fluid Silicone, CTFE
Pure Polyester Powder Coated Low Copper (<0.4%) – Aluminum.
Electronic Housing Meets Type 4X / IP66 / IP67. All stainless-steel housing is optional.
Cover O ring material: Silicone.
Process Connections STG700 Dual Head: ½ -inch NPT(female)
STG700 Inline: ½ -inch NPT(female), ½ -inch NPT male, 9/16 Aminco, G½ -B Male
Thread
Wiring Accepts up to 16 AWG (1.5 mm diameter).
Dimensions See Figure 3 and Figure 4
Net Weight STG700 Dual Head: 8.3 pounds (3.8 Kg). STG700 Inline: 3.6 pounds (1.6 Kg) with
Aluminum Housing
1
Vent/Drains are sealed with Teflon®
2
Hastelloy® C-276 or UNS N10276
4
Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.
5
Carbon Steel heads are zinc-plated and not recommended for water service due to hydrogen migration. For that service, use 316
stainless steel wetted Process Heads.
6
Hastelloy® C-276 or UNS N10276. Supplied as indicated or as Grade CW12MW, the casting equivalent of Hastelloy® C-276
6 STG700 Smart Pressure Transmitter

Communications Protocols & Diagnostics

HART Protocol
Version: HART 7
Standard Diagnostics
ST 700 top level diagnostics are reported as either critical or non-critical and readable via the DD/DTM/FDI tools or Standard
integral display. Some of the diagnostics are listed below:

Critical Diagnostics
• Electronics Module Fault.

• Meter body Memory Corruption.

• Config Data Corruption.

• Electronics Module Diagnostics Failure.

• Meter body Critical Failure.

• Sensor Communication Timeout.

Non-Critical Diagnostics
• Display Failure.

• Electronics Module Comm Failure.

• Meter body Excess Correct.

• Sensor Over Temperature.

• Fixed Current Mode.

• PV Out of Range.

• No DAC Compensation.
Refer to the product user manual for comprehensive list of diagnostics and details.
STG700 Smart Pressure Transmitter 7

Hazardous Area Certifications

MSG COMM. ELECTRICAL AMBIENT TEMP


AGENCY TYPE OF PROTECTION
CODE OPTION PARAMETERS (Ta)
Explosionproof:
Class I, Division 1, Groups A, B, C, D;
Dust Ignition Proof:
T5: -50 ºC to 85ºC
Class II, III, Division 1, Groups E, F, G; All Note 1
T6: -50 ºC to 65ºC
T6..T5
Class l, Zone 0/1, AEx db IIC T6..T5 Ga/Gb
Class ll, Zone 21, AEx tb IIIC T95o Db
Intrinsically Safe: 4-20 mA /
Class I, II, III, Division 1, Groups A, B, C, D, Note 2a -50 ºC to 70ºC
HART
FM E, F, G: T4
A ApprovalsTM Class l, Zone 0, AEx ia IIC T4 Ga
USA Ex ia IIC T4 Ga; Ex ic IIC T4 Gc
Nonincendive:
Class I, Division 2, Groups A, B, C, D 4-20 mA /
Note 1 -50 ºC to 85ºC
locations, T4 HART
Class l, Zone 2, AEx nA IIC T4 Gc
Enclosure: Type 4X/ IP66/ IP67 All All -
STANDARDS: FM Class 3600:2011; FM Class 3610: 2010; FM Class 3611: 2004; FM Class
3615: 2006; FM Class 3616: 2011; FM Class 3810: 2005; ANSI/ISA 60079-0: 2013; ANSI/UL
60079-1: 2015; ANSI/UL 60079-11: 2014; ANSI/ISA 60079-15: 2012; ANSI/UL 60079-26: 2017;
ANSI/UL 60079-31: 2015; ANSI/NEMA 250: 2003; ANSI/ IEC 60529: 2004
Explosion Proof:
Class I, Division 1, Groups A, B, C, D;
Class II, Division 1, Groups E, F, G;
Class III, Division 1, T6..T5 T5: -50oC TO 85oC
All Note 1
Class I Zone 1 AEx db IIC T6..T5 Ga/Gb T6: -50oC TO 65oC
Ex db IIC T6..T5 Ga/Gb
Zone 22 AEx tb IIIC T95o Db
Ex tb IIIC T95o Db
Intrinsically Safe:
Canadian Class I, II, III, Division 1, Groups A, B, C, D; 4-20 mA /
Note 2 -50oC TO 70oC
Standards Class II, Division 1, Groups E, F, G; HART
Association Class III, Division 1, T4
B Class I Zone 0, AEx ia IIC T4 Ga
(CSA)
USA and Class I Zone 2, AEx ic IIC T4 Gc
Canada Ex ia IIC T4 Ga
Ex ic IIC T4 Gc

Nonincendive:
Class I, Division 2, Groups A, B, C, D;
Class II, Division 2, Groups F, G; 4-20 mA /
Note 1 -50oC to 85oC
Class III, Division 2, T4 HART
Class I Zone 2 AEx nA IIC T4 Gc
Ex nA IIC T4 Gc
Enclosure: Type 4X/ IP66/ IP67 All All -
8 STG700 Smart Pressure Transmitter

MSG COMM. ELECTRICAL AMBIENT TEMP


AGENCY TYPE OF PROTECTION
CODE OPTION PARAMETERS (Ta)
STANDARDS: CSA C22.2 No. 0-10; CSA C22.2 No. 94-M91; CSA C22.2 No. 25-1966; CSA C22.2
No. 30-M1986; CSA C22.2 No. 142-M1987; CSA C22.2 No. 157-92; CSA C22.2 No. 213-M1987;
CSA-C22.2 No. 60529:05; CSA-C22.2 No. 60079-0:11; CSA-C22.2 No. 60079-1:11; CSA-C22.2
No. 60079-11:11; CSA-C22.2 No. 60079-15:12; CSA-C22.2 No. 60079-31:12; ISA 12.12.01-
2010; ISA 60079-0: 2009; ISA 60079-11: 2011; ISA 60079-15: 2009; ISA 60079-26: 2008; ISA-
60079-27:2007 (12.02.04)-2006 (R2011); UL 913 Ed. 6; UL 916:1998; ANSI/ISA-12.27.01-2011
Flameproof: SIRA 12ATEX2233X
T5: -50oC TO 85oC
All Note 1
II 1/2 G Ex db IIC T6..T5 Ga/Gb T6: -50oC TO 65oC
II 2 D Ex tb IIIC T95oC…T120oC Db
Intrinsically Safe: SIRA 12ATEX2233X
4-20 mA /
Note 2 -50oC TO 70oC
II 1 G Ex ia IIC T4 Ga HART
II 2 D Ex ia IIIIC T125oC Db

Zone 2, Increase Safety: SIRA


ATEX 12ATEX4234X 4-20 mA /
Note 1 -50oC TO 85oC
HART
II 3 G Ex ec IIC T4 Gc
Zone 2, Intrinsically Safe: SIRA
12ATEX4234X
4-20 mA /
Note 2 -50oC TO 85oC
HART
II 3 G Ex ic IIC T4 Gc

Enclosure: IP66/ IP67 All All -


STANDARDS: EN 60079-0: 2018; EN 60079-1: 2014; EN 60079-7: 2015+A1: 2018; EN 60079-
C 11: 2012; EN 60079-26: 2015; EN 60079-31: 2014
Flameproof: CSAE 22UKEX1021X
T5: -50oC TO 85oC
All Note 1
II 1/2 G Ex db IIC T6..T5 Ga/Gb T6: -50oC TO 65oC
II 2 D Ex tb IIIC T95oC…T120oC Db

Intrinsically Safe: CSAE 22UKEX1021X


4-20 mA /
Note 2 -50oC TO 70oC
II 1 G Ex ia IIC T4 Ga HART
II 2 D Ex ia IIIIC T125oC Db

Zone 2, Increase Safety: CSAE


UKEX 22UKEX1008X 4-20 mA /
Note 1 -50oC TO 85oC
HART
II 3 G Ex ec IIC T4 Gc
Zone 2, Intrinsically Safe: CSAE
22UKEX1008X 4-20 mA /
Note 2 -50oC TO 85oC
HART
II 3 G Ex ic IIC T4 Gc
Enclosure: IP66/ IP67 All All -
STANDARDS: EN 60079-0: 2018; EN 60079-1: 2014; EN 60079-7: 2015+A1: 2018; EN 60079-11:
2012; EN 60079-26: 2015; EN 60079-31: 2014
STG700 Smart Pressure Transmitter 9

MSG COMM. ELECTRICAL AMBIENT TEMP


AGENCY TYPE OF PROTECTION
CODE OPTION PARAMETERS (Ta)
Flameproof: IECEx SIR 12.0100X
T5: -50oC TO 85oC
Ex db IIC T6..T5 Ga/Gb All Note 1
T6: -50oC TO 65oC
Ex tb IIIC T95oC…T120oC Db
Intrinsically Safe: IECEx SIR 12.0100X 4-20 mA /
Note 2 -50oC TO 70oC
Ex ia IIC T4 Ga HART
Ex ia IIIC T125oC Db

Zone 2, Increase Safety: IECEx SIR


IECEx 4-20 mA /
D 12.0100X Note 1 -50oC TO 85oC
World HART
Ex ec IIC T4 Gc
Zone 2, Intrinsically Safe: IECEx SIR
12.0100X 4-20 mA /
Note 2 -50oC TO 85oC
Ex ic IIC T4 Gc HART

Enclosure: IP66/ IP67 All All -


STANDARDS: IEC 60079-0: 2017; IEC 60079-1: 2014; IEC 60079-7: 2017; IEC 60079-11: 2011;
IEC 60079-26: 2014; IEC 60079-31: 2013
10 STG700 Smart Pressure Transmitter

Flameproof :
T5: -50oC TO 85oC
Ex d IIC T6…T5 Ga/Gb All Note 1
T6: -50oC TO 65oC
Ex tb IIIC T95oC…T120oC Db
Intrinsically Safe: 4-20 mA / DE/
Note 2 -50oC TO 70oC
Ex ia IIC Ga T4 HART
SAEx
E
South Africa Zone 2, Increase Safety: 4-20 mA /
Note 1 -50oC TO 85oC
II 3 G Ex ec IIC T4 Gc HART
Zone 2, Intrinsically Safe:
4-20 mA /
Ex ic IIC T4 Gc Note 2 -50oC TO 85oC
HART

Enclosure: IP66/ IP67 All All -


Flameproof:
T5: -50oC TO 85oC
Ex db IIC T6..T5 Ga/Gb All Note 1
T6: -50oC TO 65oC
Ex tb IIIC T95oC…T120oC Db
Intrinsically Safe: 4-20 mA /
Note 2 -50oC TO 70oC
Ex ia IIC T4 Ga HART
INMETRO
F Brazil
Zone 2, Increase Safety: 4-20 mA /
Note 1 -50oC TO 85oC
II 3 G Ex ec IIC T4 Gc HART
Zone 2, Intrinsically Safe:
4-20 mA /
Ex ic IIC T4 Gc Note 2 -50oC TO 85oC
HART

Enclosure : IP 66/67 All All -


Flameproof:
T5: -50oC TO 85oC
Ex db IIC T6..T5 Ga/Gb All Note 1
T6: -50oC TO 65oC
Ex tb IIIC T 95oC Db
Intrinsically Safe: 4-20 mA /
Note 2 -50oC TO 70oC
Ex ia IIC T4 Ga HART
NEPSI
G
CHINA Zone 2, Increase Safety: 4-20 mA /
Note 1 -50oC TO 85oC
II 3 G Ex ec IIC T4 Gc HART
Zone 2, Intrinsically Safe:
4-20 mA /
Ex ic IIC T4 Gc Note 2 -50oC TO 85oC
HART

Enclosure : IP 66/67 All All -


Flameproof:
T5: -50oC TO 85oC
Ga/Gb Ex d IIC T6..T5 All Note 1
T6: -50oC TO 65oC
Ex tb IIIC Db T 85oC
EAC Intrinsically Safe: 4-20 mA /
Russia, Belarus Ga Ex ia IIC T4 X Note 2 -50oC TO 70oC
HART
I and
Kazakhstan
Zone 2, Non Sparking: 4-20 mA /
Note 1 -50oC TO 85oC
2 Ex nA IIC T4 Gc X HART
Zone 2, Intrinsically Safe: 4-20 mA /
Note 2 -50oC TO 85oC
Ga Ex ic IIC T4 X HART
STG700 Smart Pressure Transmitter 11

Enclosure : IP 66/67 All All


Flameproof: T5: -50oC TO 85oC
All Note 1
Ex d IIC T6..T5 Ga/Gb T6: -50oC TO 65oC
Intrinsically Safe: 4-20 mA /
Note 2 -50oC TO 70oC
CCoE Ex ia IIC T4 Ga HART
J
INDIA
Non Sparking 4-20 mA /
Note 1 -50oC TO 85oC
Ex nA IIC T4 Gc HART
Enclosure: IP66/ IP67 All All -
Flameproof:
T5: -50oC TO 85oC
II 1/2 G Ex db IIC T6..T5 Ga/Gb All Note 1
T6: -50oC TO 65oC
II 2 D Ex tb IIIC T95oC…T120oC Db
UATR 4-20 mA /
K Intrinsically Safe: Note 2 -50oC TO 70oC
UKRAINE HART
II 1 G Ex ia IIC T4 Ga

Enclosure: IP66/ IP67 All All -

Notes:
1. Operating Parameters:
Voltage = 11 to 42 VDC Current = 4-20 mA Normal

2. Intrinsically Safe Entity Parameters


a. Analog/ HART Entity Values
Vmax = Ui = 30V Imax = Ii = 105mA Ci = 4.2nF Li = 984 uH Pi = 0.9W
Transmitter with Terminal Block revision E or Later
Vmax = Ui = 30V Imax = Ii = 225mA Ci = 4.2nF Li = 0 Pi = 0.9W

Note : Transmitter with Terminal Block revision E or later


The revision is on the label that is on the module. There will be two lines of text on the label:
• First is the Module Part #: 50049839-001 or 50049839-002
• Second line has the supplier information, along with the REVISION:
XXXXXXX-EXXXX, THE “X” is production related, THE POSITION of the “E” IS THE REVISION.

Other Certification Options


Materials
• NACE MRO175, MRO103, ISO15156

SIL 2/3 Certification IEC 61508 SIL 2 for non-redundant use and SIL 3 for redundant use according to EXIDA and
TÜV Nord Sys Tec GmbH & Co. KG under the following standards: IEC61508-1: 2010; IEC
61508-2: 2010; IEC61508-3: 2010.
12 STG700 Smart Pressure Transmitter

Mounting & Dimensional Drawings

millimeters
Reference Dimensions: inches

Mounting Configurations: (Dual head design)

Dimensions: (Dual head design)

Figure 3 – Typical mounting dimensions of STG735, STG745 & STG775 for reference

Refer to the User’s manual (34-ST-25-44) for full details on mounting and installation.
STG700 Smart Pressure Transmitter 13

millimeters
Reference Dimensions: inches

Mounting Configurations (Inline Designs)

Dimension (Inline Design)

Figure 4 – Typical mounting dimensions of STG74S, STG77S, STG78S, & STG79S for reference

Refer to the User’s manual (34-ST-25-44) for full details on mounting and installation.
14 STG700 Smart Pressure Transmitter

Model Selection Guide

Model Selection Guides are subject to change and are inserted into the specifications as guidance only.

Model STG700
Gauge Pressure Transmitters
Model Selection Guide
34-ST-16-122, Issue 17
Instructions: Make selections from all Tables using column below the proper arrow. Asterisk indicates availability. Letter (a) refers to
restrictions highlighted in the restrictions table. Tables delimited with dashes.
List Price: Price equals the sum of prices for all selections made.
Key I II III IV V VI VII VIII IX
STG7_ _ - ______ - _ - _ - ___ - ___ - _ - ____ - _ _, _ _, _ _ - 0000

KEY NUMBER URL/Max Span LRL Min Span Units Selection Availability
50 (3.5) -14.7 (-1.0) 0.5 (.035) psi (bar) STG735
Gauge
500 (35) -14.7 (-1.0) 5 (.35) psi (bar) STG745
Dual Head
3000 (210) -14.7 (-1.0) 30 (2.1) psi (bar) STG775
50 (3.5) -14.7 (-1.0) 0.5 (.035) psi (bar) STG73S
500 (35) -14.7 (-1.0) 5 (.35) psi (bar) STG74S
Gauge
3000 (210) -14.7 (-1.0) 30(2.1) psi (bar) STG77S
In-Line
6000 (420) -14.7 (-1.0) 60 (4.2) psi (bar) STG78S
10000 (690) -14.7 (-1.0) 100 (6.9) psi (bar) STG79S

TABLE I METER BODY SELECTIONS


Process Head/Reference Head Material1b Barrier Diaphragm Material
a. Process
316L SS A_____ * *
Head & Plated Carbon Steel
Hastelloy® C - 276 B_____ * *
Diaphragm
316L SS E_____ * * * * *
Materials 316 Stainless Steel1c
Hastelloy C - 276 F_____ * * * * *
Hastelloy C - 276/316 Stainless Steel Hastelloy C - 276 J_____ * * * * *
Silicone Oil 200 _ 1_ _ _ _ * * * * *
b. Fill Fluid
Fluorinated Oil CTFE _2____ * * * * *
Size/Type Material
9/16" Aminco Same as Process Head __A___ * * *
1/2" NPT (female) Same as Process Head 1a __G___ * * * * *
c. Process Connection
1/2" NPT (male) Same as Process Head __H___ * * *
G 1/2 B Threaded Fitting Same as Process Head __B___ * * *
M20 (male) Same as Process Head __N___ * * *
None ___0__ * * *
Carbon Steel ___C__ * *
316 SS ___S__ * *
d. Bolt/Nuts Materials
Grade 660 (NACE A286) with NACE 304 SS Nuts ___N__ * *
Grade 660 (NACE A286) Bolts & Nuts ___K__ p p
Super Duplex ___D__ p p
Head Type Vent Type Location Vent Material
None None None None ____0_ * * *
Single Ended None None None ____1_ * *
e. Vent/Drain Single Ended Standard Vent Side Matches Head Material1 ____2_ * *
Type/Location Single Ended Center Vent Side Stainless Steel Only ____3_ t t
Dual Ended Standard Vent End Matches Head Material1 ____4_ * *
Dual Ended Center Vent End Stainless Steel only ____5_ t t
1
Dual Ended Std Vent/Plug Side/End Matches Head Material ____6_ * *
None _____0 * * *
Teflon® or PTFE (Glass Filled) _____A * *
f. Gasket Materials ®
Viton _____B * *
Graphite _____C * *
1
Except Carbon Steel Heads shall use 316SS Vent/Drain & Plugs and or 1/2" adapters
1a
STG735,745,775 supplied via 1/2" flange adapter same material as process head except carbon steel shall use 316 SS
1b
Reference head available with Dual Head Gage models only. In-Line Gage models are supplied with Process Head only.
1c When selected for In-Line Gage models the Process Head / Bonnet is supplied in Dual Certified SS316/316L
STG700 Smart Pressure Transmitter 15

STANDARD REVERSED 90°/STANDARD


SELECTION 14 SELECTION 2 SELECTION 3

STG79S
STG77S, STG78S
STG73S,STG74S
STG775
STG735,STG745
H H H
TABLE II Meter Body & Connection Orientation
2
Standard High Side Left, Ref Side Right / Std Head Orientation 1 * * * * *
Head/Connect 2
Orientation
Reversed Ref Side Left, High Side Right 2 * *
2 0
90/Standard High Side Left, Ref Side Right / 90 Head Rotation 3 h h

TABLE III AGENCY APPROVALS


No Approvals Required 0 * * * * *
<FM> Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof A * * * * *
CSA Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof B * * * * p
ATEX Explosion proof, Intrinsically Safe & Non-incendive C * * * * *
IECEx Explosion proof, Intrinsically Safe & Non-incendive D * * * * *
Approvals SAEx Explosion proof, Intrinsically Safe & Non-incendive E * * * * *
INMETRO Explosion proof, Intrinsically Safe & Non-incendive F * * * * *
NEPSI Explosion proof, Intrinsically Safe & Non-incendive G * * * * *
EAC-Customs Union(Russia,Belarus and Kazakhstan)EX Approval Flameproof,Intrinsically Safe I * * * * *
CCoE Explosion proof, Intrinsically Safe & Non-incendive J * * * * *
UATR Flameproof, Intrinsically Safe & Dustproof K * * * * *

TABLE IV TRANSMITTER ELECTRONICS SELECTIONS


Material Connection Lightning Protection
Polyester Powder Coated Aluminum 1/2 NPT None A__ * * * * *
Polyester Powder Coated Aluminum M20 None B__ * * * * *
a. Electronic Housing Polyester Powder Coated Aluminum 1/2 NPT Yes C__ * * * * *
Material & Connection Polyester Powder Coated Aluminum M20 Yes D__ * * * * *
Type 316 Stainless Steel (Grade CF8M) 1/2 NPT None E__ * * * * *
316 Stainless Steel (Grade CF8M) M20 None F__ * * * * *
316 Stainless Steel (Grade CF8M) 1/2 NPT Yes G__ * * * * *
316 Stainless Steel (Grade CF8M) M20 Yes H__ * * * * *
Analog Output Digital Protocol
b. Output/ Protocol
4-20mA dc HART Protocol _H_ * * * * *
Indicator Ext Zero,Span & Config Buttons Languages
None None None __0 * * * * *
None Yes (Zero/Span Only) None __A * * * * *
c. Customer Interface Standard(w/Internal
Zero,Span&Config None EN, RU __S * * * * *
Selections
buttons)
Standard(w/Internal
Zero,Span&Config Yes EN, RU __T * * * * *
buttons)

TABLE V CONFIGURATION SELECTIONS


a. Application Diagnostics
Software Standard Diagnostics 1__ * * * * *
Write Protect Fail Mode High & Low Output Limits3
b. Output Limit, Disabled High> 21.0mAdc Honeywell Std (3.8 - 20.8 mAdc) _1_ * * * * *
Failsafe & Write Disabled Low< 3.6mAdc Honeywell Std (3.8 - 20.8 mAdc) _2_ * * * * *
Protect Settings Enabled High> 21.0mAdc Honeywell Std (3.8 - 20.8 mAdc) _3_ * * * * *
Enabled Low< 3.6mAdc Honeywell Std (3.8 - 20.8 mAdc) _4_ * * * * *
General Configuration
c. General Factory Standard __S * * * * *
Configuration Custom Configuration (Unit Data Required from customer) __C * * * * *
2
Left side/Right side as viewed from the customer connection perspective
3
NAMUR Output Limits are configurable by customer
4
Process connections will vary on In-Line Models
16 STG700 Smart Pressure Transmitter

STG79S
STG77S, STG78S
STG73S,STG74S
STG775
TABLE VI CALIBRATION & ACCURACY SELECTIONS STG735,STG745
Accuracy Calibrated Range Calibration Qty
Accuracy and
Calibration
Standard Factory Standard Single Calibration A * * * * *
Standard Custom (Unit Data Required) Single Calibration B * * * * *

TABLE VII ACCESSORY SELECTIONS


Bracket Type Material
None None 0___ * * * * *
Angle Bracket Carbon Steel 1___ * * * * *
Angle Bracket 304 SS 2___ * * * * *
a. Mounting
Angle Bracket 316 SS 3___ * * * * *
Bracket
Marine Approved Bracket 304 SS 4___ * *
Flat Bracket Carbon Steel 5___ * * * * *
Flat Bracket 304 SS 6___ * * * * *
Flat Bracket 316 SS 7___ * * * * *
Customer Tag Type
b. Customer Tag No customer tag _0__ * * * * *
One Wired Stainless Steel Tag (Up to 4 lines 26 char/line) _1__ * * * * *
Unassembled Conduit Plugs & Adapters
c. Unassembled
No Conduit Plugs or Adapters Required _ _ A0 * * * * *
Conduit
1/2 NPT Male to 3/4 NPT Female 316 SS Certified Conduit Adapter _ _ A2 n n n n n
Plugs &
1/2 NPT 316 SS Certified Conduit Plug _ _ A6 n n n n n
Adapters
M20 316 SS Certified Conduit Plug _ _ A7 m m m m m

TABLE VIII OTHER Certifications & Options: (String in sequence comma delimited (XX, XX, XX,….)
No additional options 00 * * * * *
NACE MR0175; MR0103; ISO15156 Process wetted parts only FG * * * * *
b
NACE MR0175; MR0103; ISO15156 Process wetted and non-wetted parts F7 c c c c c
Marine (DNV,ABS,BV,KR,LR) MT d d d d d
EN10204 Type 3.1 Material Traceability FX * * * * *
Certificate of Conformance F3 * * * * *
b
Calibration Test Report & Certificate of Conformance F1 * * * * *
Certifications & Certificate of Origin F5 * * * * *
Warranty FMEDA (SIL 2/3) Certification FE j j j j j
Over-Pressure Leak Test Certificate (1.5X MAWP) TP * * * * *
Cert Clean for O2 or CL2 service per ASTM G93 OX e e e e e
PM Certification⁵ PM * * * * *
Extended Warranty Additional 1 year 01 * * * * *
Extended Warranty Additional 2 years 02 * * * * *
b
Extended Warranty Additional 3 years 03 * * * * *
Extended Warranty Additional 4 years 04 * * * * *

TABLE IX Manufacturing Specials


Factory Factory Identification 0000 * * * * *
RESTRICTIONS
Available Only with Not Available with
Restriction Letter
Table Selection(s) Table Selection(s)
b Select Only one option from this group
c Id _ _ _ 0,N,K,D _ _ _
d Iva C, D, G, H _ _ VIIa 1, 2, 3, 5, 6, 7 _ _ _
e Ib _2____
Ie _ _ _ _ 4, 5, 6 _ _
h
VIIa 1, 2, 3, 4, 5, 6, 7 _ _ _
j Vb _ 1,2_
m IV a B,D,F,H _ _
n IV a A,C,E,G _ _
p III B- No CRN number available
t Ia J_____

The PM option is available on all Smartline Pressure Transmitter process wetted parts such as process heads, flanges, bushings and vent plugs except plated
carbon steel process heads and flanges. PM option information is also available on diaphragms except STG and STA in-line construction pressure transmitters.
FIELD INSTALLABLE ACCESSORY KITS
Description Kit Number Price
Terminal Strip w/o Lightning Protection Kit for HART 50129832-501 Note P
Terminal Strip w/Lightning Protection for HART Modules 50129832-502 Note P
HART Electronics Module 50129828-501 Note P
HART Electronics Module w/connection for external configuration buttons 50129828-502 Note P
Standard Display Module 50126003-501 Note P
Note P - For part number pricing please refer to WEB Channel
PRODUCT MANUALS
Description Part Number
ST 700 Smart Transmitter User Manual - English 34-ST-25-44
ST 700 Smart Transmitter HART Communications Manual - English 34-ST-25-47
ST 700 Smart Transmitter Safety Manual - English 34-ST-25-37
All product documentation is available at www.process.honeywell.com.
Sales and Service
For application assistance, current specifications, ordering, pricing, and name of the nearest Authorized Distributor,
contact one of the offices below.

ASIA PACIFIC EMEA AMERICAS


Honeywell Process Solutions, Honeywell Process Solutions, Honeywell Process Solutions,
Phone: + 800 12026455 or Phone: + 800 12026455 or Phone: (TAC) (800) 423-9883
+44 (0) 1202645583 +44 (0) 1202645583 or (215) 641-3610
(TAC) hfs-tac- (Sales) 1-800-343-0228
[email protected]
Email: (Sales) Email: (Sales)
Australia
Honeywell Limited [email protected] [email protected]
Phone: +(61) 7-3846 1255 or or
FAX: +(61) 7-3840 6481 (TAC) (TAC)
Toll Free 1300-36-39-36 [email protected] [email protected]
Toll Free Fax:
1300-36-04-70

China – PRC - Shanghai Web Web


Honeywell China Inc. Knowledge Base search Knowledge Base search
Phone: (86-21) 5257-4568 engine http://bit.ly/2N5Vldi engine http://bit.ly/2N5Vldi
Fax: (86-21) 6237-2826

Singapore
Honeywell Pte Ltd.
Phone: +(65) 6580 3278
Fax: +(65) 6445-3033

South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799 6114
Fax: +(822) 792 9015

Specifications are subject to change without notice.

For more information


To learn more about SmartLine Transmitters,
visit www.process.honeywell.com
Or contact your Honeywell Account Manager

Process Solutions
Honeywell
1250 W Sam Houston Pkwy S
Houston, TX 77042

Honeywell Control Systems Ltd


Honeywell House, Skimped Hill Lane
Bracknell, England, RG12 1EB

Shanghai City Centre, 100 Jungi Road


Shanghai, China 20061
34-ST-03-122
March 2024
www.process.honeywell.com ©2024 Honeywell International Inc.

You might also like