BEDO

Innovating Education EML 101


ELECTRIC
MACHINES
LAB

BEDO electrical machine


systems provide a complete
range of integrated teaching
equipment for various subjects in
both AC and DC machines.

Power supply unit:


- One Input, Three phase + N, 220/380 V AC, 50 Hz, 25 Amp.
- One Output, Fixed Three phase + N, 220/380 V AC, 50 Hz, 10 Amp.
- One Output, Variable Three phase + N, 0 – 220/380 V AC, 50 Hz, 5 Amp.
- One Output, Variable DC supply, 0 – 220 V DC, 5 Amp.
- One Output, Variable DC supply, 0 – 220 V DC, 1 Amp
Digital Programmable AC Voltmeter capable of measuring in the following
ranges (0 to 1, 2, 10, 20, 50, 110, 250 or 500) V AC, with selectable RMS or
AVG measuring method, display accuracy 0.5% F.S
Digital Programmable DC Voltmeter capable of measuring in the following
ranges (0 to 50 or 250) mV DC and (0 to 1, 5, 10, 50, 100 or 500) V DC, with
display accuracy 0.5% F.S
Digital Programmable AC Ammeter capable of measuring in the following
ranges (0 to 50, 100, 250 or 500) mA AC and (0 to 1, 2.5 or 5) A AC, with
selectable RMS or AVG measuring method, display accuracy 0.5% F.S
Digital Programmable DC Ammeter capable of measuring in the following
ranges (0 to 2, 5, 50, 200 or 500) mA DC, (4 to 20) mA DC and (o to 2 or 5) A
DC, with display accuracy 0.5% F.S
High range DC Ammeter capable of measuring from 0 to 20 A DC, with display
accuracy 0.2% F.S
Programmable Single Phase AC Digital Multimeter, with the following features:
- Measuring the AC RMS voltage from 10 to 300 V AC, with 0.5% accuracy.
- Measuring the AC RMS current from 0.2 to 5.5 A AC from CT, with 0.5% accuracy.
- Measuring the frequency from 30 to 100 HZ, with 0.5% accuracy.
- Measuring the active power, with 1% accuracy.
- Measuring the power factor with 0.5% accuracy.

Programmable Three Phase AC Digital Multimeter, with the following features


- Measuring harmonics of any voltage or current up to 31th harmonics.
- Plotting 3-phase AC waveform current or voltage.
- Measuring each phase frequency from 30 to 100 Hz, with 0.5% accuracy.
- Measuring AC RMS voltage difference between 2 phases from 20 to 520 V AC, with 0.5% accuracy.
- Measuring AC RMS voltage difference between each phase and neutral from 10 to 300 V AC, with 0.5%
accuracy.
- Measuring each phase AC RMS current from 0.2 to 5.5 A AC from CT, with 0.5% accuracy
- Measuring each phase maximum apparent current value.
- Measuring each phase active power (KW), reactive power (KVAR) and apparent power (kVA), with 1%
accuracy.
- Measuring power factor for each phase, with 2% accuracy.
- Measuring total active power for 3 phases in (KW).
- Measuring total active power maximum value.
- Measuring total reactive power for 3 phases in (KVAR).
- Measuring total apparent power for 3 phases in (KVA).
- Measuring total power factor for 3 phases.
- Two active power counters (KWh).
- Two reactive power counters (KVARh).
- Four user counters.

Programmable Three phase AC Synchroscope, with the following features:


- Measuring AC voltage difference between a phase and neutral line of a generator (U-N).
- Measuring generator frequency.
- Measuring voltage difference between a phase and neutral line of a bus-bar (R-N).
- Measuring bus-bar frequency.
- Measuring frequency difference between bus-bar and generator.
- Measuring voltage difference between bus-bar and generator.
- Measuring phase angle for bus-bar phase (U).
- Programmable ΔV, ΔF, Δθ for check synch relay.
- Synch Check Enable.
- Dead Bus Enable.

Three phase harmonics panel with lamps


Rotating Machines
- Dc compound motor/ generator
Specifications
- The machine has two excitation windings, one for series and one for shunt excitation.
- Input voltage for motor 220 Volt DC.
- Output voltage of generator 220 volt DC.
- Excitation voltage 220 volt DC.
DC COMPOUND EXCITATION MACHINE
- Nominal speed 3000 rpm.
- Nominal power 300 W.
- Safe 4mm sockets for input and output.
- Safety earth connection provided.
Typical experiments
- Winding resistance measurements.
- No Load test.
- Speed Control. SHUNT

- Nominal Load and over load test. SERIES

- Magnetic Characteristics.
- Electromechanical Characteristics.
- Determination of working characteristics.
- The external characteristics of a compound generator for level, under and over compounding.

- Single phase Capacitor Start motor


Specifications
- The rotor is a squirrel cage while the stator has two windings, the primary winding is directly connect-
ed to the power source while the secondary winding is normally connected in series to a capacitor and
the series in parallel with the primary for producing a rotating magnetic field.
- Input voltage 220 volt AC.
- Input frequency 50 Hz. Single Phase Capacitor

- Nominal speed 3000 rpm.


- Nominal power 300 W.
- Safe 4mm sockets for input.
- Safety earth connection provided.
Typical experiments
- Winding resistance measurements.
- Short Circuit test. MAIN WINDING

- No Load test. AUXILIARY


WINDING

- Efficiency determination.
- External characteristics.
- Determination of working characteristics.
- Three phase slip ring induction motor
Specifications
- Stator windings could be connected in Y or Δ schemes.
- The motor can be used as slip ring or squirrel cage motor if the rotor brushes is short circuited.
- Input voltage 220/380 volt Δ/Y.
- Input frequency 50 Hz.
- Nominal speed 3000 rpm.
- Nominal Power 300 W.
- Safe 4mm sockets for input.
- Safety earth connection provided
Typical experiments
- Winding resistance measurements.
- Short Circuit test.
- No Load test.
- Efficiency determination.
- External characteristics.
- Determination of working characteristics.
- Star / Delta Starting.
-
- Starting three phase induction motor with a starting rheostat.
- Speed control of a squirrel cage induction motor.

- Single phase Universal motor


Specifications
- The stator has two poles and their windings are in series with the commutator rotor windings through
its brushes.
- Can be powered both from DC or AC Source.
- Input voltage 220 volt AC/DC.
- Input frequency 50/60 Hz. UNIVERSAL MOTOR
- Nominal speed 3000 rpm.
- Nominal Power 300 W.
- Safe 4mm sockets for input.
- Safety earth connection provided
Typical experiments
- Winding resistance measurements.
- Short Circuit test.
AC
- No Load test.
- Efficiency determination. DC

- External characteristics.
- Determination of working characteristics.

- Synchronous three phase machine


Specifications
- Can be used as generator or motor.
- The stator can be configured for star or delta schemes.
- Input voltage for motor 220/380 volt AC Δ/Y. SYNCHRONOUS MACHINE

- Output voltage of generator 220/380 volt AC Δ/Y.


- Input frequency 50 Hz.
- Output frequency 50 Hz.
+/- E

- Nominal speed 3000 rpm.


- Nominal power 300 watt. -/+ E
- Safe 4mm sockets for input and output.
- Safety earth connection provided U١ V١ W١

Typical experiments
- Winding resistance measurements. U٢ V٢ W٢

- Short Circuit test.


- No Load test.
- Efficiency determination.
- Determination of External characteristics.
- Determination of working characteristics.
- Effects of load on a synchronous motor.
- Starting a synchronous motor as an alternator.
- Leading and lagging power factor of a synchronous motor.
- Tacho-generator Tacho-generator

Specifications
- The tacho-generator is a DC Generator which produce a DC
voltage that is directly and linearly proportional to the speed.
- Used to measure the rotating machines speed by measuring
the produced voltage and convert it to rpm.
- Ratio is 20 V DC per 1000 rpm.
- Nominal speed 3000 rpm.

DC Motor starter
Specifications
- Used to start DC shunt excited motor and control its speed.
- The dc motor starter protected with a fuse and thermal switch.
- The excitation and armature connection are performed using safe 4mm sockets.
- The adjustment potentiometer varies the armature voltage and current while the excitation voltage and
current are fixed.
- Armature voltage from 0 to 200 VDC.
- Excitation voltage 200 VDC.

Stepped Resistor Starter


Specifications
- This starter is designed to start slip ring motors by means of a variable resistance connected to its
brushes through 4mm safety connectors.
- A 5 positions switch allows stepping the resistance from 0 (open) to Maximum, Medium, Minimum and
Short Circuit.
Y/Δ starter switch
Dynamometer
• Digital Torque measuring meter
- Measuring range from 0 to 20 Nm.
- ±1% accuracy.
• Load cell:
- Measuring range from 0 to 20 Nm.
• Braking DC generator
- It is designed for braking and measuring the torque of rotating machines.
- The unit can be used as a DC motor or a DC generator.
- Output voltage 220 VDC.
- Excitation Voltage 220 VDC.
- Nominal speed 3000 rpm.
- Nominal power 300 W.
- Safe 4mm sockets for input and output.
Single-phase transformer
Specifications
- The primary windings have a central tap to make it possible to supply full or half of nominal voltage.
- The secondary windings consist of two separate windings can be connected in series for more voltage
or for separate usage.
- Primary voltage 220 (110 +110) volt.
- Secondary voltage 220 and 380 volt.
- Nominal power 300 VA.
- Frequency 50 HZ.
- Safe 4mm sockets for input and output.
Typical experiments
- Measurement of the transformer windings resistance.
- Measurement of transformation ratio.
- No load test.
- Short circuit test.
- Determination of the polarity.
- Determination of regulation characteristics.
- Determination the efficiency.

Three phase transformer


Specifications
- Consist of three single phase transformers.
- Primary winding of each single phase transformer consist of two 110 volt windings which can be
connected in series or parallel.
- Secondary winding of each single phase transformer consist of two 190 volt windings which can be
connected in series or parallel.
- Primary and secondary windings of the three single phase transformers can be connected star or
delta to form the three phase transformer.
- Nominal power 300 VA.
- Nominal frequency 50 HZ.
- Safe 4mm sockets for input and output.
Typical experiments
- Measurement of the transformer windings resistance.
- Measurement of transformation ratio.
- No load test.
- Short circuit test.
- Determination of the polarity.
- Determination of regulation characteristics.
- Determination the efficiency.

Loads
- Resistive Load
Specifications
- Three resistive switched load banks controlled by three rotary switches with an “Off” plus 7 positions.
- Nominal DC voltage 220 volt.
- Nominal star voltage 380 V AC.
- Nominal delta voltage 220 V AC.
- Nominal power 100 W per bank.
- Load value from 547 Ohm to 3770 Ohm, Fuse protected.
- Safe 4mm sockets for connection.
Typical experiments
- Winding resistance measurements.
- Short Circuit test.
- No Load test.
- Efficiency determination.
- External characteristics.
- Determination of working characteristics.

- Inductive Load
Specifications
- Three inductive switched load banks controlled by three rotary switches with an “Off” plus 7 positions.
- Can be connected in series, parallel, star or delta configuration.
- Nominal star voltage 380 V AC.
- Nominal delta voltage 220 V AC.
- Nominal frequency 50 HZ.
- Nominal power 100 VAR@220V AC per bank.
- Load value from 3H to 12 H, Fuse protected.
- Safe 4mm sockets for connection.
- Capacitive Load
Specifications
- Three capacitive switched load banks controlled by three rotary switches with an “Off” plus 7 positions.
- Can be connected in series, parallel, star or delta configuration.
- Nominal star voltage 380 V AC.
- Nominal delta voltage 220 V AC.
- Nominal frequency 50 HZ.
- Nominal power 116 VAR@220V AC per bank.
- Load value from 1 µf to 7 µf, Fuse protected.
- Safe 4mm sockets for connection.

Three phase Variac


Specifications
- Nominal frequency 50 Hz.
- Capacity 1.5 KVA.
- Input voltage 380 V AC.
- Output from 0 V to 430 V AC.
- Nominal output current 2 Amp.
BEDO
innovating education

SCAN HERE Headquarters:23 Amer Street, Off


Messaha Square, Dokki, Giza Egypt
Factory:36th, industrial Zone,
6 t h O c t o b e r C i t y, G i z a , E g y p t
Te l : + 2 ( 0 2 ) 3 7 612 2 3 8
F a x : + 2 ( 0 2 ) 3 7 614 5 7 6
M o b : + 2 010 6 7 3 9 9 3 47 / 2 010 9 4 4 4 6 8 81
E-mail : [email protected]
w w w. b e d o e g . c o m

You might also like