29 /04/2024

SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CONDUCTORS, BARE
1. 1
BARE CONDUCTORS TYPE ACAR/ACSR/ACSR-AW/AAAC Applicable Standards: 10-TMSS-01

1. 1 Page 1 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Bahra Advance Cable Manufacture Co. ACAR, ACSR, ACSR/AW AAAC, and Type tests on all PQ Letter
Ltd ACSR/AW Condor type of conductors Based on S&SD letters # 15-01562-1-30504401
Saudi Arabia performed (October dated 18th March 2015 & #
03-09, 2015) at 15-04785-1-30504401 dated 18th November,
Po Box 5989 Jeddah 21432 , Saudi Kinectrics 2015, it is pre-qualified with the following
Arabia Laboratory Toronto conditions:
Canada,
Contact Person - Mr. Loai Taha Al-Bar, Report No. WARRANTY:
Sale Manager K-419714-RC-0001- Ten (10) years extended warranty/guarantee in
Phone - +966-2-591-1115 R01 & . respect of defects due to design, manufacture,
Email ID - [email protected] K-419714-RC-0002- installation & workmanship from the date of the
R01 Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award
Kinectrics Report # and from the date of first delivery in case of
K-419605-RC-0001- direct material supply order .This was confirmed
R00 & in writing by the manufacturer through their letter
K-419605-RC-0002- # (BCC/SEC/LAB/GSM/MZ) dt: December 9, 2015.
R00
Previously Bahra Cable Co.
Kinectrics Report #
K-419714-RC-0001-
R01 &
K-419714-RC-0002-
R01

(ACSR/AW Condor)
Type test performed
at Bahra Cables
Laboratory (October
16-18, 2018)
Report #
AS-181018-01

Grease type test


conducted in
Petro-Lubricant
Testing
Laboratories, Inc.
-USA,
Lab Report No.
21082703 dated
23/12/2021

1. 1 Page 2 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MIDAL CABLE , ACAR, ACSR, ACSR/AW and AAAC Type test conducted PQ Letter
Saudi Arabia from 25.08.2015 to Based on S&SD letter # 15-09640-030504401
04.09.2015 at dated November 24, 2015, it is pre-qualified with
Plant -Al Khobar different the following conditions:
laboratories in
P.O. Box 2312 Al Khobar 31952 Saudi Germany Viz SAG, WARRANTY:
Arabia ISP Institues, State Ten (10) years extended warranty from the date
Material testing of PAC of the first turnkey project in case of
Contact Person - Mr.Ammar Al Khuzaei institute ,FGH etc. contract award or date of first delivery in case of
General Manager Marketing & Sales , (Test Report # direct material supply order as
Mr. Mahadi Hussain 2015-049A, confirmed through Letter # Nil dated 19.10.2014.
Phone - +966-13-8988989 2015-049C &
+966-509994288 2015-049D)
Email ID - [email protected]
[email protected] Type test performed
Website - http://www.midalcale.com for ACSR/AW
Condor
(Greased &
un-greased)
ACSR Drake
Un-greased, ACAR
548
(Greased &
un-greased),
AAAC 500
(Greased &
un-greased),
ACSR Condor and
Conductor Grease
at SPIE Laboratory
SAG GmbH
Report#

2020-090 A dated
25.11.2020
2020-090 B dated
02.12.2020
2020-090 G dated
02.02.2021
2020-090 I dated
02.02.2021
2020-090 H dated

1. 1 Page 3 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

02.02.2021
2020-090 K dated
08.02.2021
2020-090 J dated
08.02.2021
2020-090 L dated
02.03.2021
2020-090 M dated
16.03.2021

MIDAL CABLE LTD. ACAR, ACSR, ACSR/AW and AAAC Tests performed at:
BAHRAIN Manufacturer’s Lab.
(2014/2013/2010)
Plant -Bahrain Report #:
AAAC/P-1634-C/14/
Midal Cable Ltd. Bahrain Po Box 5939 01
Manama, Bahrain, Bldg. 744 Road 5128 AAAC/P-1196-C/13/
Block 951 Askar Road Bahrain. 08
Manama , Bahrain ACSR/P-890-C/10/0
4
Contact Person - Mr. Ammar Al Khuzaei ACSR/P-1087-C/11/2
Phone - +973-17832832 7
Email ID - [email protected] ACSR/AW/P-696C/0
Website - http://www.midalcable.com/ 8/29
ACSR/AW/P-814C-A
/09/03
ACAR/P-1000-C/11/
23

STERLITE ACAR, ACSR, ACSR/AW and AAAC Tests performed at: PQ Letter
INDIA Based on TS&SD Letter #
FGH, Germany 10-F001691/01-03032301 dated 19/06/2010, it is
S. No. 99/P, Madhuban Dam Road, (Dec., 2009) pre-qualified with the following condition:
Rakholi Silvassa 396230 - India
Report # H1005, WARRANTY:
Contact Person - Mr. Vivek Ananad H10006, H10007 Ten (10) years extended warranty/guarantee in
Phone - +91-97-6555-3878 and H10008 respect of defects due to design, manufacture,
Email ID - [email protected] installation & workmanship from the date of
Website - Provisional Acceptance Certificate (PAC) of the
http://www.sterlitetechnologies.com turnkey project in case of contract award or date
of delivery in case of direct material supply order.

1. 1 Page 4 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL SYSTEMS ACAR, ACSR, ACSR/AW and AAAC Type Tests PQ Letter
Saudi Arabia performed for ACSR Based on S&SD letter# 13-02020-01-30504401
Conductor dated July 30, 2013, it is pre-qualified with the
Plant -3Rd Industrial Area, Al Kharaj at:Kinectrics - following: conditions.
Road, Riyadh Saudi Arabia Canada dated 11th
Feb 2013, Report #
Po Box 301 , Riyadh 11411 , North Righ K419415-RC-0001-R CONDITION:
Road Between Exit 5 & 6 Riyadh , 01 The first batch of AAAC, ACSR/AW & ACAR type
Saudi Arabia conductors shall be type tested at an
independent testing laboratory in the presence of
Riyadh (03) SEC/National Grid SA repreentatives and one
approved third party inspector and all cost
Contact Person - Sultan Alghamdi " VIP pertaining to tests shall be borne by the
key Account Manegr "; Saleh manufacturer.
Almehaijeen "Projects Sales Engineer "
Phone - 920006111 WARRANTY:
Contact Person Email ID - Ten (10) years extended warranty/guarantee in
[email protected]; respect of defects due to design, manufacture,
[email protected] installation & workmanship from the date of
Website - www.alfanar.com Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmd by the manufacturer
through their letter #C-PRQ-2013-02 dated June
17, 2013.

SOUTHWIRE ACAR, ACSR, ACSR/AW and AAAC


United States

Website - http://www.southwire.com/

ALCOA ACAR, ACSR, ACSR/AW and AAAC


United States

Website -
http://www.alcoa.com/usa/en/home.as
p

1. 1 Page 5 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JEDDAH CABLE CO. ACAR, ACSR, ACSR/AW Drake, Type test performed PQ Letter
Saudi Arabia ACSR/AW Condor (un-greased) and for ACSR/AW Based on S&SD Letter No. 16-09867-30504401
AAAC, Condor dated 7 Dec 2016 , JEDDAH CABLE Co. Jeddah
Plant -jeddah ACSR/AW Condor (greased) (un-greased) at SPIE -K.S.A is Pre-qualified with following condition.
Laboratory SAG
Po Box 31248 , Jeddah 21497 Jeddah , GmbH WARRANTY:
Saudi Arabia Report# 2020-093 Ten (10) years extended warranty from the date
dated 11- December of PAC of the first turnkey project in case of
jeddah 2020. contract award or date of first delivery in case of
direct material supply order.
Contact Person - Mr. Alaa Dandachi , Type Tests for
Mohammad Said Minkara Conductors type WARRANTY:
Phone - +966-126360770, 0541462998 ACSR, ACSR/AW, Ten (10) years extended warranty in respect of
Email ID - AAAC, ACAR were the defects due to design, manufacturing,
[email protected] performed in installation and workmanship from the date of the
Contact Person Email ID - KINECTRIC Provisional Acceptance Certificate (PAC) of the
[email protected] International Inc. first project (in case of contract award) and from
Website - Laboratory– the date of first delivery in case of direct material
http://www.cables.energya.com CANADA , supply order shall be provided as confirmed by
KINECTRICS the manufacturer through their letter
Report# JCC-EP-TT-20-044-05 dated December 23, 2020.
K-419635-RC-0001-
R01,
K-419635-RC-0002-
R01,
K-419635-RC-0003-
R01,
K-419635-RC-0004-
R01,
JCC-EP-PQ-0102-1
4-34.

Type test performed


for ACSR/AW
Condor (grease) at
SPIE Laboratory
SAG Germany from
March 2021 - May
2021
Report# 2021-009-A
dated 5 May 2021.

1. 1 Page 6 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

APAR INDUSTRIES LTD. Imdad Support & ACAR, ACSR, ACSR/AW and AAAC Tests Performed for PQ Letter
INDIA technical AAAC Conductor Based on TS&SD Letter # 10-01566-2-03032300
PO Box 56451 Riyadh (Stress Strain, dated 14/06/2010, it is pre-qualified with the
Plant -Nalagarh Plant, Silvassa Plant 11554 Breaking Strength, following conditions:
Phone - 011-4657556 x UTS and
Nalagarh Plant: 222,311 Longitudinal CONDITION:
Khasra No. 467, Hadbast No. 101, Email – Smoothness) at The first batch of ACSR, ACSR/AW & ACAR type
Muuza Beer Plassi Tec. Nalagarh P.O [email protected] VEIKI-VNL, conductors shall be type tested at an
Manjhauli (Jagatkhana) District Solan Budapest – Hungary independent testing laboratory in the presence of
(H.P) 174 101 India in Jan., 2014) (03) SEC/National Grid SA repreentatives and one
Tel: 0091-01795-200384 Report # 7765/VNL approved third party inspector and all cost
E-mail: [email protected] pertaining to tests shall be borne by the
manufacturer, as confirmed by the manufacturer
through letter # AIL/BRD/PQ/SEC/19, dt: 22nd
SILVASSA Plant: May, 2010.
Survey No. 148/1 Kudacha, Silvassa,
Rakholi Road, Silvassa (U.T.OFD & NH) WARRANTY:
-396230 INDIA Ten (10) years warranty from the date of PAC of
Tel: 0091-260-2630193-194 the turnkey project in case of contract award or
Fax, 0091-260-2630916 date of delivery in case of direct material supply
E-mail: [email protected] order. This has been confirmed in writing by the
manufacturer; through letter # AIL/BRD/
SEC/PQ/19 dated 22nd May 2010.

OMAN CABLE INDUSTRIES ACAR, ACSR, ACSR/AW and AAAC WARRANTY:


Oman Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
muscat installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Website - first turnkey project in case of contract award or
http://www.omancables.com/ date of delivery in case of direct material supply
order.

1. 1 Page 7 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SAUDI CABLE ACSR/AW Condor Type test performed PQ Letter:


Saudi Arabia for ACSR/AW Based on S&SD letter # 20-01622-30504401
Condor at VEIKI lab, dated September 14, 2020, Saudi Cables Co.,
Plant -Jeddah, Saudi Arabia Budapest, Hungary, KSA is pre-qualified for ACSR/AW Condor
Report# Conductor as conforming to National Grid SA
Saudi Cable Company VEIKI-VNL#11464/V specification # 10-TMSS-01 with the following
P.O. BOX 4403 Jeddah 21491 NL dated 31- conditions:
Industrial Area-Jeddah, Saudi Arabia August- 2020.
WARRANTY:
Fax Number: +966 12 637 9877 Ten (10) years extended warranty/guarantee for
the offered ACSR/AW Condor Conductor in
Jeddah respect of defects due to design, manufacture,
installation & workmanship from the date of
Contact Person - Ammar R. Qari Provisional Acceptance Certificate (PAC) of the
Phone - +966 12 608 7666 first turnkey project in case of contract award or
Email ID - [email protected] , date of delivery in case of direct material supply
[email protected] order. Vide Saudi Cable Company letter No. NIL
Contact Person Email ID - Dated 10 September 2020
[email protected]
Website - www.saudicable.com

1. 1 Page 8 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RIYADH CABLES ACAR, ACSR, ACSR/AW Drake, Type test performed


Saudi Arabia ACSR/AW Condor and and AAAC for ACSR/AW
Condor at
Plant -Riyadh KINECTRICS INC.
Laboratory Toronto,
P.O. Box 26862- Riyadh, 11496 Riyadh Ontario, M8Z 5G5,
, Saudi Arabia Canada
2nd Industrial City, Al Kharj Road, street Report#
No. 175, 3rd Lane Zone D. Riyadh, K-313063-RC-0001
Kingdom of Saudi Arabia R00 dated 15-Aug -
2018
Contact Person - Mr. Dr. Abdulmohsen Accepted and
Aliheraish – Vice Executive Director; approved vide S&SD
Mr. Mohammad Al-Shmoury, letter No.
Phone - +966 11 2650850 Ext:238 ; 18-03572-1-305044
+966 11 2651415 01 Dated 01 October
Email ID - [email protected]; 2018.
[email protected];
[email protected]
Website - Tests performed at:
http://www.riyadh-cables.com/ Riyadh Cables
Laboratory,
Riyadh K.S.A
Reports #
2014-OHL-1-ACSR
CONDOR (May
2014)
2014-OHL-2-ACSR/
AW DRAKE (July
2014)
2015-OH-1-ACAR
547.4 (August 2015)
2016-OH-1-AAAC
(17-18 May 2016)

1. 1 Page 9 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY CABLES ACSR/AW (un-greased) Type test conducted PQ Letter


Saudi Arabia on ACSR / AW Based on S&SD letter # #20-01877-30504401
Condor dated November 11, 2020, the manufacturer is
Plant -Yanbu, Saudi Arabia (un-greased) prequalified for BARE CONDUCTORS as
VEIKI Laboratory confirming to National Grid SA specification #
P.O Box 31670 Yanbu Al Sinaiyah Report No. 10-TMSS-01, with the following conditions:
41912, Saudi Arabia 11421/VNL Date :
27.07.2020 WARRANTY
Contact Person - Hassan A. Hassan, SGS Report No. : Ten (10) years extended warranty from the date
Maher Mohamed 01.15065.01 Rev.1 of PAC of the first turnkey project (in case of
Phone - Tel : +966 14 3570166, Mobile: Date : 24.07.2020 contract award) or date of first delivery (in case
+966 540069254, Fax : +966 VEIKI/VNL of direct material supply order), as confirmed,
143572223 laboratory through their Letter #Nil dated April 10, 2017, shall
Email ID - [email protected] HUNGARY be applicable for the equipment to be supplied to
[email protected] SEC/National Grid SA.
Contact Person Email ID -
[email protected]
[email protected]
Website -
http://www.elsewedyelectric.com/FE/C
ommon/Companies.aspx?ID=27&g=3

Total = 13

CONDUCTORS, BARE
1. 2
GUY WIRE STRAND, GALVANIZED (GROUNDING) Applicable Standards: 10-TMSS-02

SOUTHWIRE
United States

Website - http://www.southwire.com/

TREFILEUROPE
FRANCE

Website -
http://www.mittalsteel.com/Facilities/Eu
rope/Mittal+Steel+Gandrange/Trefileuro
pe/

FLORIDA WIRE & CABLE


United States

1. 2 Page 10 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JOSLYN
United States

Website -
http://www.joslynhivoltage.com/

Total = 4

CONDUCTORS, BARE
1. 3
OVERHEAD GROUND WIRE (OGW) Applicable Standards: 10-TMSS-03

MIDAL CABLE LTD.


BAHRAIN

Plant -Bahrain

Midal Cable Ltd. Bahrain Po Box 5939


Manama, Bahrain, Bldg. 744 Road 5128
Block 951 Askar Road Bahrain.
Manama , Bahrain

Contact Person - Mr. Ammar Al Khuzaei


Phone - +973-17832832
Email ID - [email protected]
Website - http://www.midalcable.com/

SOUTHWIRE
United States

Website - http://www.southwire.com/

TREFILEUROPE
FRANCE

Website -
http://www.mittalsteel.com/Facilities/Eu
rope/Mittal+Steel+Gandrange/Trefileuro
pe/

1. 3 Page 11 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALCOA
United States

Website -
http://www.alcoa.com/usa/en/home.as
p

APAR INDUSTRIES LTD. PQ Letter


INDIA Based on TS&SD Letter # 10-01566-2-03032300
dated 14/06/2010, it is pre-qualified with the
Plant -Nalagarh Plant, Silvassa Plant following conditions:

Nalagarh Plant: CONDITION:


Khasra No. 467, Hadbast No. 101, The first batch of aluminum clad steel (ACS) type
Muuza Beer Plassi Tec. Nalagarh P.O shall be type tested at an independent testing
Manjhauli (Jagatkhana) District Solan laboratory in the presence of (03) SEC/National
(H.P) 174 101 India Grid SA repreentatives and one approved third
Tel: 0091-01795-200384 party inspector and all cost pertaining to tests
E-mail: [email protected] shall be borne by the manufacturer. This has
been confirmed in writing by the manufacturer
through letter # AIL/BRD/PQ/SEC/19, dt: 22nd
SILVASSA Plant: May, 2010.
Survey No. 148/1 Kudacha, Silvassa,
Rakholi Road, Silvassa (U.T.OFD & NH) WARRANTY:
-396230 INDIA Ten (10) years extended warranty/guarantee in
Tel: 0091-260-2630193-194 respect of defects due to design, manufacture,
Fax, 0091-260-2630916 installation & workmanship from the date of
E-mail: [email protected] Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
through their letter#AIL/BRD/PQ/SEC/19, dt: 22nd
May, 2010.

ECN CG SA
SPAIN

1. 3 Page 12 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

SAUDI CABLE
Saudi Arabia

Plant -Jeddah, Saudi Arabia

Saudi Cable Company


P.O. BOX 4403 Jeddah 21491
Industrial Area-Jeddah, Saudi Arabia

Fax Number: +966 12 637 9877

Jeddah

Contact Person - Ammar R. Qari


Phone - +966 12 608 7666
Email ID - [email protected] ,
[email protected]
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

1. 3 Page 13 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RIYADH CABLES
Saudi Arabia

Plant -Riyadh

P.O. Box 26862- Riyadh, 11496 Riyadh


, Saudi Arabia
2nd Industrial City, Al Kharj Road, street
No. 175, 3rd Lane Zone D. Riyadh,
Kingdom of Saudi Arabia

Contact Person - Mr. Dr. Abdulmohsen


Aliheraish – Vice Executive Director;
Mr. Mohammad Al-Shmoury,
Phone - +966 11 2650850 Ext:238 ;
+966 11 2651415
Email ID - [email protected];
[email protected];
[email protected]
Website -
http://www.riyadh-cables.com/

Total = 9

CONDUCTORS, BARE
1. 4
OPTICAL FIBER GROUND WIRE (OPGW) Applicable Standards: 10-TMSS-04

AFL TELECOMMUNICATIONS EUROPE PREVIOUSLY ALCOA FUJIKURA LTD (AFL).


LTD
United Kingdom

Website - http://www.afltele.com/

1. 4 Page 14 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AFL TELECOMMUNICATIONS GMBH ASLH-D(S) BB Type Tests Previously Draka Comteq Germany GmbH & KG.
GERMANY 96 SMF AL4/A20SA Performed at:
161/21-20,0 Intertek (Sep, 2016) WARRANTY:
Monchengladbach , Germany Report # TB 3246/16 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
ASLH-D(S)bb installation & workmanship from the date of
48 SMF AL4/A20SA Provisional Acceptance Certificate (PAC) of the
163/20-20,0 Type Tests first turnkey project in case of contract award or
(Equivalent to Wolf Performed at: date of first delivery in case of direct material
with 48 Fiber). Intertek (May, 2017) supply order.
Report # TB 3450/17
ASLH-D(S)BB, 96 SMF/NZDSF
AL4/A20SA 65/39-14,6

ASLH-D(S)BB, 96 SMF/NZDSF
AL4/A20SA 78/76-24,0 Type Tests
Performed at:
ASLH-D(S)B, 36 SMF A20SA 37-2,9 Intertek (Oct, 2015)
(ARAMCO Project) Report # TB 3134/15

Type Tests
Performed at:
Intertek (Oct, 2015)
Report # TB 3135/15

Type Tests
Performed at:
Intertek (May, 2011)
Report # TB 2118/11

1. 4 Page 15 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JIANGSU ZHONGTIAN TECHNOLOGY RADYA International OPGW, 70kN 13.3mm, 48 Fibers Tests performed at: PQ Letter
CO.LTD (ZTT) PO Box: 61891 Riyadh Kinectrics Canada Based on TS&SD Letter # 10-01654-03032301
CHINA 14211 K.S.A OPGW, 120kN, 17.3mm, 48 Fibers (July, 2011) Report # dated June 05, 2010 and S&SD Letter
Tel: +966-11-4966667 K-419311-RC0001-R 12-05204-1-30504401 dated February 04, 2013,
Chinanantong, China Email: OPGW, 15.3mm (70kN) & 18.4mm 00 it is prequalified with the following condition:
afzal.mohammad@kfbgr (120kN), 96 Fibers
oup.com.sa WARRANTY:
Tests performed at: Ten (10) years extended warranty/guarantee in
OPGW, 18.5mm (77kN) 48 Fibers Kinectrics Canada respect of defects due to design, manufacture,
(OPGW -48B1-185 [77.7 ; 253.9]) (July, 2011) Report # installation & workmanship from the date of
K-419311-RC0002-R Provisional Acceptance Certificate (PAC) of the
OPGW, 70kN (16mm), 96 Fibers– 00 first turnkey project in case of contract award or
96G652-AST-141 (Greased Type) date of first delivery in case of direct material
supply order.
OPGW, 120kN (17.9mm), 96 Fiber – Tests performed at:
96G652-AST-180 (Greased Type) Kinectrics Canada PQ Letter:
Report # Based on TS&SD Letter # 10-01654-03032301
K-419653-RC-0002- dated June 05, 2010, S&SD Letter
R00 (June 11,2015) 12-05204-1-30504401 dated February 04, 2013
& Report # and S&SD Letter # 20-01696-30504401 dated
K-419653-RC-0003- October 21, 2020, Manufacturer is pre-qualified
R00 (June 11,2015). for OPTICAL FIBER GROUND WIRE (OPGW) as
conforming to National Grid SA Specification #
Tests performed at: 10-TMSS-04 with the following conditions:
Kinectrics Canada
Report #
K-419653-RC-0001- WARRANTY:
R00 (May 04,2015). Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the OPTICAL FIBER
Type Tests GROUND WIRE (OPGW) for OPGW
performed at: (96-G652-AST-141/180-70KN/120KN-GREASED
SECRI Report # TYPE) in respect of the defects due to design,
CT20-03268 & manufacturing, installation and workmanship from
CT20-03266 the date of Provisional Acceptance Certificate
(August 17,2020) (PAC) of the first turnkey project (in case of
for OPGW, contract award) or from the date of first delivery
TICW Report # (in case of direct material supply order), as
CT20-03270Y1 (Sep confirmed by the manufacturer, through their
01,2020) for Letter Ref. # Nill dated 29.01.2024
Grease.

1. 4 Page 16 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES Innovative Systems OPGW-69/0-48N, Tests performed at: PQ Letter


SOUTH KOREA (isys) OPGW-122/048N, Kinectrics Canada Based on TS&SD letter # 10-02583-03032301
PO Box 60606 Riyadh (Nov, 2011) Report # dated 19/09/2010, it is pre-qualified with the
Plant -Gumi/Korea 11555,KSA K-419319-RC-0001- following condition:
Phone - R00
13 F Ls Tower ,127, Ls-Ro, +966-11-460-8161 WARRANTY:
Dongan-Gu, Anyang-Si, Gyeonggi-Do, Email - [email protected] OPGW-69/048S OPGW-122/0-48S Tests performed at: Ten (10) years extended warranty/guarantee in
Korea KERI (Feb, 2012) respect of defects due to design, manufacture,
Report # installation & workmanship from the date of
Contact Person - Jiyup Baik 2012TC00216 & Provisional Acceptance Certificate (PAC) of the
Phone - +82-544697602 OPGW-84/0-48N 2012TC00217 first turnkey project in case of contract award or
Email ID - [email protected] (Retrofitting project) date of first delivery in case of direct material
Website - http://www.lscns.com LS Optical Fibers Tests performed at: supply order as confirmed by the manufacturer
Kinectrics Canada through their letter no.nil, dt: jan 8th, 2010. .
(Nov, 2014) Report
#
K-419624-RC-0001-
OPGW-53/23 – 96 core 70 kN, 13kA, R00
13.3mm)
Tests performed at:
KERI (Feb, 2014)
OPGW-88/38 0-96 core 120 kN, 13kA, Report #
17.2mm) 2014TC00150

Tests performed at:


Kinectrics Canada
(Mar. 2017) Report #
K-419842-1-R00

Tests performed at:


Kinectrics Canada
(Mar. 2017) Report #
K-419842-2-R00

PHILLIPS FITEL
CANADA

Website - http://www.phillipsfitel.com

1. 4 Page 17 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PRYSMIAN TELECOM Zamil Group Holding co, 6715 120 kN/24 kA 48 core, Tests performed at: PREVIOUSLY "PIRELLI"
SPAIN Commercial Div 6716 70 kN/13 kA 48 core Kinectrics Canada
www.zamilcd.com.sa Report # PQ Letter:
Plant -Vilanova I La Geltru/Spain Phone - K-419533-RC-0002- Based on S&SD Letter # 22-00491-30504401
966-0-504-320-776 8609 120 kN/24 kA 96 core, R01 (May, 2014) dated April 14, 2022 Prysmian is pre-qualified for
Ctra. C-15,Km, 2-P.I. Masia D’En Notari Email - 8610 70 kN/13 kA 96 core Report # OPTICAL FIBER GROUND WIRE (OPGW) as
08800 Vilanova I La Geltru ( Spain) [email protected] K-419530-RC-0001- conforming to National Grid SA specification
a 8146 77.8kN/18 kA 48 core (94P64Dz) R00 (Jan, 2013) 10-TMSS-04, with the following conditions:
Contact Person - Mr. Toni Nieto
Phone - +34608749306 WARRANTY:
Email ID - 9217 73.3 kN/29.1 kA, 19.0 mm, 96 Type Tests Twenty (20) years extended warranty/guarantee
[email protected] core (90Q74z) Performed at: against corrosion protection of OPGW in respect
Website - Kinectrics Canada of defects due to design, manufacture,
http://www.prysmiangroup.com 1. OPGW 120kN (96 fibers), Type: Report # installation and workmanship from the date of
80N84DzG (11541), 27.5KA, 18mm K-313065-RC-0001- Provisional Acceptance Certificate (PAC) of the
(Greased) R00 (Jan, 2019) first turnkey project in case of contract award or
2. OPGW 70kN (96 fibers), Type: date of first delivery in case of direct material
51H54DzG (11542), 19.4KA, 15.1mm 1. Shanghai supply order, as confirmed by the manufacturer
(Greased) National Center, vide letter # Letter #SS 15022021-01 dated
3. Anti-Corrosion Grease (for China Type Test 15/02/2020.
OPGW) Report No. CT21-
4. OPGW 120kN (96 fibers), Type: 03000 dated
67L85z(10755), 24KA, 16.7mm 15.10.2021 PQ Letter:
5. OPGW 70kN (96 fibers), Type: 2. Shanghai Based on S&SD letter #22-00491-30504401
32C51z(10756), 13KA, 13.2mm National Center, dated April 14, 2022 & letter #
China Type Test 22-01014-30504401 dated August 10, 2022 the
Report No. CT21- manufacturer is prequalified for OPTICAL FIBER
02626 dated GROUND WIRE (OPGW), as conforming to
02.09.2021 National Grid SA specification # 10-TMSS-04,
3. Shanghai with the following conditions:
National Center,
China Type Test WARRANTY:
Report No. CT21- Ten (10) years extended warranty from the date
02627 dated of PAC of the first turnkey project (in case of
03.09.2021 contract award) or date of first delivery (in case
4. Report # of direct material supply order), as confirmed,
PRYSMIAN-OPGW through their Letter #OPGW-KSA-0722 dated
67L85z(10755) July 19, 2022, shall be applicable for the
dated 29.11.2021, equipment to be supplied to SEC/National Grid SA.
TICW Shanghai
Report#
CT21-04430-1 dated

1. 4 Page 18 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

23.12.2021 & TICW


Shanghai Report#
CT21-04431-1 dated
04.01.2022
5. Report #
PRYSMIAN-OPGW
32C51z(10756)
dated 29.11.2021,
TICW Shanghai
Report#
CT21-04430-2 dated
23.12.2021 & TICW
Shanghai Report#
CT21-04431-2 dated
04.01.2022

DRAKA NK
FINLAND

Website - http://www.draka.com/

FURUKAWA ELECTRIC CO. LTD.


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

FUJIKURA
JAPAN

Website - http://www.ffcpg.com.my/

PIRELLI
ITALY

BRUGG TELECOM AG
SWITZERLAND

Website - http://www.brugg.com/

1. 4 Page 19 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CORNING CABLES
United Kingdom

Prescot Merseyside , United Kingdom

Website -
http://www.corningcablesystems.com/

1. 4 Page 20 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Fiberoptics Co., Ltd OPGW-120kN, 36 Fibers, 17.9mm Tests performed at: PQ Letter
KOREA, Republic of Al-Tube type, (New) OPGW (G.652D Kinectrics Canada, Based on TS&SD letter# 09-F00730/03-03032301
96Core) 14.9mm, 70 kN/13 kA / Spec KERI & Taihan (2011) dated 24th August 2009, it is prequalified with the
Plant -Yesan Gun (County), No. : 1501031A, OPGW (G.652D, and (New) Taihan following condition:
Chungcheongnam Do (Province), Korea 96Core) 18.5mm, 120 kN/24 kA / Spec Electric Wire Co. Ltd
No. : 1501032A - Korea has
50-19, Eungbong-ro, Eungbong-myeon successfully WARRANTY:
completed the type Ten (10) years extended warranty/guarantee in
Yesan Gun (County) tests of Fiber Optical respect of defects due to design, manufacture,
Ground Wire installation & workmanship from the date of
Contact Person - Kwang Ik, Sohn (OPGW) in Provisional Acceptance Certificate (PAC) of the
Phone - 82-41-330-7821 independent first turnkey project in case of contract award or
Email ID - [email protected] laboratory date of first delivery in case of direct material
Contact Person Email ID - (KINECTRICS, supply order , as confirmed by the manufacturer
[email protected] Canada) report # through their letter no.nil, dt: 30/03/2008.
Website - www.taihanfiber.com K-419657-RC-0001-
R00 during March (New) PQ letter:
16, 2015 & Based on S&SD letter # 17-08663-30504401
RC-0002-R00 during dated December 18, 2017, Taihan Electric Wire
March 17,2015 in Co. Ltd - Korea is pre-qualified for Fiber Optical
the presence of Ground Wire (OPGW) as conforming to latest
SEC/National Grid National Grid SA specification # 10-TMSS-04
SA Engineers.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # TENA171206-01, dated December
06, 2017.

(New-1) PQ letter:

Based on S&SD letter # 23-01878-30504401,


dated 13th September 2023, the plant name and
location is updated as:

Plant: Taihan Fiberoptics Co., Ltd, Yesan Gun


(County), Chungcheongnam Do (Province), Korea

1. 4 Page 21 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Complete Address: 50-19, Eungbong-ro,


Eungbong-myeon, Yesan Gun (County),
Country: Republic of Korea
Tel. No. : 82-41-330-7821
Email: [email protected]

(New-1) WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # no. Nil, dated October 12, 2022.

Total = 13

CONDUCTORS, BARE
1. 5
BARE, COPPER-CLAD STEEL GROUNDING CONDUCTOR AND GROUND ROD Applicable Standards: 10-TMSS-05

1. 5 Page 22 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GANSEC SHENGYUEAN WIRE & REZAYAT TRADING CO


CABLE CO. LTD. LTD
CHINA POST BOX:90, AL-
KHOBAR –
Plant - NO:8, LANE 24, QIANSHI 31952,DAMMAM,SAUDI
STREET, LIUSHI TOWN, YUEGING CITY, ARABIA
WENZHOU CITY, ZHEJIANG PROVINCE, +966 555737286
CHINA. sudhagar.nadarajan@re
zayat.net
1. Business Communication address:
ZONE:7, N0:399, PENGHUI AVENUE,
CHONGFU TOWN DEVELOPMENT
ZONE,
TONGXIANG CITY, JIAXING CITY,
ZHEJIANG PROVINCE, CHINA.

2. Plant Address:
NO:8, LANE 24, QIANSHI STREET,
LIUSHI TOWN, YUEGING CITY,
WENZHOU CITY
ZHEJIANG PROVINCE, CHINA.

3. Branch Address:
LANE 658, GAUNGFULIN ROAD,
SONGJIANG DISTRICT, SHANGHAI
,CHINA .

Contact Person - MR.ZHAO FENGXUAN


Phone - +86 21 37762753
Email ID -
[email protected]
Contact Person Email ID -
[email protected]
Website -
www.gansecshengyuean.com

ILJIN CORP./JIWOONG ELECTRIC CO.


SOUTH KOREA

Website -
http://www.jiwoong.co.kr/main
eng.html

1. 5 Page 23 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Copperweld Bimettalics LLC Litwin Saudi Arabia Previously LTV Copperweld, name has been
United States Company Ltd. changed based on Copperweld Bimettalics letter
P.O. Box 3739, # Nil dated January 03,2018.
Plant -Fayetteville, Tennessee Al-Khobar 31952,
Kingdom of Saudi Arabia.
254 Cotton Mill Road
Fayetteville, Tennessee 37334 Jamal Mohammad Abu
U.S.A. Ajinah
Manager Industrial
Tennessee Trading
+966 13 893 8557; +966
Contact Person - Mr. Dustin Smith 504 169 720
Phone - +1 931-433-0400 / +1 [email protected]
615-377-4200
Website -
http://www.bimettalics-copperweld.co
m

COMSCOPE BIMETALS
United States

Statesville, Nc , United States

FM SUDAFIX Including Exothermic Welding and Grounding


United Kingdom connectors.

Nottingham , United Kingdom

Website - http://www.fmsudafix.com/

1. 5 Page 24 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

A. N. Wallis & Co. Ltd. 16mm dia, 3000mm length, Drawing # Type tests PQ Letter:
United Kingdom ERB130 conducted at Based on S&SD letter # 16-10652-030504401
ELEMKO SA THIVA dated December 25,2016, A. N. Wallis & Co. Ltd.
Plant -United Kingdom GREECE, Report # – UK is pre-qualified for Grounding Rod &
32050 dated accessories as conforming to National Grid SA
Greasley Street, Bulwell, Nottingham, 20/12/2021 specification # 10-TMSS-05, with the following
United Kingdom conditions:

Nottingham WARRANTY:
Ten (10) years Extended Warranty as confirmed
Contact Person - Mark Rimmington, through Letter No. ANW/NG SA/ SEC / EW/ L01 /
Director 2016 dated 27/10/2016 shall be applicable for all
Phone - +44(0)1159271721 supplies to the Company by A. N. Wallis & Co.
Email ID - [email protected] Ltd. – UK
Website - www.an-wallis.com

ABB Furse 16mm dia. Type Tests PQ Letter


Saudi Arabia 3,000mm length, completed at Elemko Based on S&SD letter #MPQ353651-ClassI(a)
SA-Greece, Test -2018 dated June 07, 2020, ABB Furse –
ABB Furse Factory, 2nd Industrial Drawing No. Report # 31893 Dammam – Saudi Arabia is prequalified for
Area, P.O Box 355251, Riyadh 11383 RB 235 IP 01-18 Rev (18) dated March 23, COPPER-CLAD STEEL GROUND ROD as
Saudi Arabia 2020 conforming to National Grid SA specification #
10-TMSS-05, Rev.02 with the following
Riyadh conditions:

Contact Person - Mr. Ahmed Hussain, WARRANTY


Hana Al Mani Ten (10) years extended warranty/guaranty from
Phone - +966 11 484 5600 Ext 2710 the date of (PAC) of the Turnkey project (In case
Email ID - of contract award) and from the date of delivery
[email protected], for the direct material supply order. The
[email protected] guarantee/warranty shall be applicable from first
Website - www.ABB.com.sa project and shall cover all the cost of materials
and labor as per warranty/guarantee of materials
and workmanship and subsequently reduced
yearly in case of future project award. This was
confirmed in writing by ABB Furse through their
letter # nil dated # 20.07.2018.

1. 5 Page 25 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SADAF Electric Industries Co. (SEICO Type test reports On HOLD based on ED, Chief Engineering letter #
Ltd). (4790482924-OTHE 23-02463-030504101 dated December 19, 2023.
Saudi Arabia RS-S1 dated July
25, 2022, Previously " Legrand Saudi electric Co.", the
Plant -Jeddah 4790482924-OTHER name has been changed to " SADAF Electric
S-S2 & Industries Co. (SEICO Ltd).
Jeddah,KSA 4790482924-OTHER
S-S3 dated 29th July
Jeddah 2022) for copper Note:
clad steel grounding Previously " Saudi Electric Industries Company
Contact Person - Mr. Kurian Mathew - conductors (19#7, Ltd. (SEICO) ", the name has been changed to "
CEO, Robben Zacharia - Sales 7#7 & 7#5) Legrand Saudi Electric Industries Company Ltd".
Manager respectively. based on their letter # Nil dated October 30,
Contact Person Email ID - 2017.
[email protected] -
[email protected]
Website - www.seico-sa.com

1. 5 Page 26 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Alamana Technology Factory for Ground Rod: Type Tests PQ Letter


Electrical Industries Performed: Based on S&SD letter Ref. # MPQ993951-Class
Saudi Arabia 16mm dia. Ground Rod: I(b)-2021 dated June 14, 2023, the manufacturer
3,000 mm length, • Laboratory Al Hoty is prequalified for Copper clad steel ground rod
Plant -Riyadh Stranger Ltd. Co. Al up to 380kV conforming to National Grid SA
Drawing No. Khobar. Test Report specification # 10-TMSS-05 Rev.03, with the
Plant: 2nd Industry City – St. 190, ACC-00120 # RDMET237-R1 following conditions:
Al-Shifa Emam Muslim Road, 190 dated March 26,
2023 CONDITION
Contact Person - Mr. Abdelfattah Awad Environment test shall be performed on first
(Senior Projects Manager) batch of ground rods at an independent testing
Phone - + 966-1- 4239741- Ext-122 ; + laboratory in presence of approved third party
966553163111 inspector and report shall be submitted.
Contact Person Email ID -
[email protected]; WARRANTY
[email protected]; Ten (10) years extended warranty/guarantee to
[email protected] SEC/National Grid SA for the offered Copper clad
Website - www.atgroups.net steel ground rod in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their letter Ref. # ATG/2021/SR-001014
dated 25/03/2021.

Total = 9

CONDUCTORS, BARE
1. 6
HEAT-RESISTANT ALUMINUM ALLOY BARE CONDUCTORS FOR OVERHEAD LINE Applicable Standards: 10-TMSS-06

1. 6 Page 27 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES Innovative Systems Tests performed at: PQ Letter


SOUTH KOREA (isys) GAP Type & INAVR Type Conductors: KERI Based on TS&SD letter #
PO Box 60606 Riyadh (Jan. 31 to Feb. 27, 10-02584-03032301dt:19/09/2010, it is
Plant -Gumi/Korea 11555,KSA, GZTACSR and ZTACIR 2012) pre-qualified for Heat Resistance Conductors,
Contact Person Kamal Report # subject to the following conditions:
13 F Ls Tower ,127, Ls-Ro, AL Muhanna 2012TC00150,
Dongan-Gu, Anyang-Si, Gyeonggi-Do, Phone - 2012TC00149, WARRANTY:
Korea +966-11-460-8161 2012TC00218 Ten (10) years extended warranty/guarantee in
Email - [email protected] & 2012TC00219 respect of defects due to design, manufacture,
Contact Person - Jiyup Baik installation & workmanship from the date of
Phone - +82-544697602 Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] first turnkey project in case of contract award or
Website - http://www.lscns.com date of first delivery in case of direct material
supply order as confirmed by the manufacturer
through letter#Nil, dt: 8th Jan, 2010.

Full technical support will be provided to SEC


during operation of Gap Conductors for minimum
five (5) years period from first project as
confirmed through LS letter # LS/LHJ-100526/00
dated 26th May 2010

FUJIKURA VISCAS CORPORATION INAVR Type Conductors: WARRANTY:


JAPAN ZTACIR/AS, XTACIR/AS Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Website - http://www.ffcpg.com.my/ installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

1. 6 Page 28 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sumitomo Electric Industries Middle East Regional GAP Type & INAVR Type Conductors: Test performed at: Based on S&SD letter#20-02008-30504401 dated
JAPAN Office GTACSR, GZTACSR and Toyoura Works 13 December 2020, the name was changed from
Mr. Amjad Abdelaziz ZTACIR/AS, XTACIR/AS (JECTEC) Nov./Dec. J-Power Systems to Sumitomo Electric Industries
Plant -JAPAN-Hitachi ,General Manager 2014, Oct. 2009,
[email protected]. Jan. 2013, Mar. PQ Letter
3-13-16 Mita- Minato-Ku, Tokyo jp 2004, & Sep 2007 Based on TS&SD letter# 09-00649-1-03032301
108-0073 , Japan dated 28 March 2009 and S&SD letter no.
Report # 15-00017-1-30504401 dated 8th Feb 2015 it is
Contact Person - Shiro Nomura & Mr. JTR12AY091245, pre-qualified for Heat Resistant Conductors
Amjad Abdelaziz JTR12AY-13092, subject to the following conditions:
Contact Person Email ID - JTR12-AY044167,JT
[email protected] & R12-AY07980, WARRANTY:
[email protected] JTR12-AY07092, Ten (10) years extended warranty in respect of
Website - JTR12-AY12107,JTR the defects due to design, manufacturing &
http://www.jpowers.co.jp/english/inde 12-AY09913 & workmanship from the date of the Provisional
x.html JTR12-Ay141633 Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) and from the
Type Tests date of first delivery in case of direct material
performed from 27th supply order shall be provided as confirmed by
Nov to 5th Dec 2014 the manufacturer through their letters #
at: #JLX80-15-0013 dated 5th Feb 2015 and
Japan Electric Cable JLX80-15-0022 dated March 02nd, 2015.
technology
Center(JECTEC) Lab
Shizuoka, Japan.

Report#
IR-2014-5001-40261
-001

Total = 3

CONDUCTORS, BARE
1. 7
Bare Copper Conductor Applicable Standards: 10-TMSS-07

1. 7 Page 29 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Bahra Advance Cable Manufacture Co. Soft Annealed stranded BARE COPPER PQ Letter
Ltd CONDUCTORS, Round Non-compacted Based on S&SD letter # 23-02034-01-30504401
Saudi Arabia (CLASS2) Product ID:14110090 (size dated October 17, 2023, the manufacturer is
50mm2) 14110110 (size 95mm2 ) prequalified for Substation Grounding Materials
Po Box 5989 Jeddah 21432 , Saudi 14110120 (size 120mm2 ), 14110130 as confirming to National Grid SA specification #
Arabia (size 150mm2) 14110150 (size 10-TMSS-07 with following conditions:
240mm2).
Contact Person - Mr. Loai Taha Al-Bar, TYPE TEST:
Sale Manager Tinned coated stranded bare copper All type/ special/routine tests as per SEC/National
Phone - +966-2-591-1115 conductors, Round Non-compacted Grid SA Standards/Specifications shall be
Email ID - [email protected] (CLASS-2) PRODUCT ID:14111005 conducted on the offered product in an
(Nominal CSA 25mm2), 14111007 accredited test lab in the presence of three (03)
(Nominal CSA= 50MM2), 14111009 SEC/National Grid SA engineers and one (01)
(Nominal CSA= 95MM2), 14111010 SEC/National Grid SA approved 3rd party
(Nominal CSA= 120MM2), 14111013 Independent Inspection Agency (IIA) inspector in
(Nominal CSA = 150mm2), 14111013 the month of November 2023. All cost of which
(Nominal CSA= 240MM2) shall be borne by the manufacturer. This was
Annealed bare soft copper strip; confirmed in writing by the manufacturer through
BCT250250 ( Size 50 mm2), their letter Ref. # Nil dated 23.November.2021.
BCT200350 (Size 60 mm2), BCT250350
(Size 75 mm2), BCT300350 (Size 90 WARRANTY:
mm2), BCT250450 (Size 100 mm2), Ten (10) years extended warranty/guarantee to
BCT300440 (Size 120 mm2), SEC/National Grid SA for Substation Grounding
BCT300540 (Size 150 mm2), Materials in respect of the defects due to design,
BCT400430 (Size 160 mm2), manufacturing, installation and workmanship from
BCT310630 (Size186 mm2), the date of Provisional Acceptance Certificate
BCT380530 (Size190 mm2), (PAC) of the first turnkey project (in case of
BCT400525 (Size 200 mm2), contract award) or from the date of first delivery
BCT380625 (Size228 mm2), (in case of direct material supply order), as
BCT400625 (Size 240 mm2), confirmed by the manufacturer, through their
BCT500520 (Size 250 mm2), Letter Ref. # Nil dated 28.December.2021.
BCT500620 (Size 300 mm2),
BCT506.320 (Size315 mm2),
BCT500720 (Size 350 mm2)
Annealed, soft insulated copper
conductor; Cu/XLPE/PVC 1kV - 175
(size 50mm2), 274 (size 95mm2), 326
(size 120mm2), 367 (Size 150mm2),
505 (size 240mm2)
Insulation Cable for Surge Arrestor
grounding conductor; Cu//XLPE/PVC
1X50MM2, 6kV - Size 50mm2, Size

1. 7 Page 30 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

95mm2, Size 120mm2, Size 240mm2


Copper cladded steel ground rod; 3/4
inch, Length 3M, 5/8" inch, Length 3M

Ground rod accessories; Coupler -34 &


35, Driving stud, Split Bolt connector,
Rod and tape clamp, Rebar clamp,
C-shaped connector, Rod to cable
clamp, Rod to Cable Lug Clamp -D type.

Riyadh Cables Group Company Annealed soft Bare Copper Stranded Type Tests are PQ Letter
Saudi Arabia Conductor – 50, 95, 120 & 240 mm2. successfully Based on S&SD letter # 23-02036-01-30504401
performed in dated October 18, 2023, the manufacturer is
Plant -Riyadh - Saudi Arabia ELEMKO SA, prequalified for Bare copper Stranded Conductor
Lightning & High as confirming to National Grid SA specification #
2nd Industrial City, Al Kharj Road Voltage Laboratory, 10-TMSS-07 with following conditions:
Thiva, Greece from
Riyadh 22.05.2023 to
07.06.2023. WARRANTY:
Contact Person - Dr. Abdulmohsen Reports # 32144, Ten (10) years extended warranty/guarantee to
Aliheraish 32145, 321446 & SEC/National Grid SA for Substation Grounding
Phone - +966 11 2650850 Ext:238 32147. Materials in respect of the defects due to design,
Email ID - [email protected]; manufacturing, installation and workmanship from
[email protected]; the date of Provisional Acceptance Certificate
[email protected] (PAC) of the first turnkey project (in case of
Contact Person Email ID - contract award) or from the date of first delivery
[email protected] (in case of direct material supply order), as
Website - confirmed by the manufacturer, through their
http://www.riyadh-cables.com Letter Ref. #TMN-10/0105 dated 03rd October
2023.

Total = 2

CONDUCTOR, INSULATED
2. 1
POWER CABLE, XLPE, CU OR AL, 1-CORE, 69 kV Applicable Standards: 11-TMSS-01

2. 1 Page 31 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SAUDI CABLE
Saudi Arabia

Plant -Jeddah, Saudi Arabia

Saudi Cable Company


P.O. BOX 4403 Jeddah 21491
Industrial Area-Jeddah, Saudi Arabia

Fax Number: +966 12 637 9877

Jeddah

Contact Person - Ammar R. Qari


Phone - +966 12 608 7666
Email ID - [email protected] ,
[email protected]
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

RIYADH CABLES Tests performed at:


Saudi Arabia KEMA
Netherlands (Jan.
Plant -Riyadh 2014)
Report # TIC
P.O. Box 26862- Riyadh, 11496 Riyadh 1489-13
, Saudi Arabia
2nd Industrial City, Al Kharj Road, street
No. 175, 3rd Lane Zone D. Riyadh,
Kingdom of Saudi Arabia

Contact Person - Mr. Dr. Abdulmohsen


Aliheraish – Vice Executive Director;
Mr. Mohammad Al-Shmoury,
Phone - +966 11 2650850 Ext:238 ;
+966 11 2651415
Email ID - [email protected];
[email protected];
[email protected]
Website -
http://www.riyadh-cables.com/

2. 1 Page 32 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY EGYTECH CABLE CO. CONDITION:


EGYPT All type/design and routine/sample tests shall be
conducted at SEC approved independent
Egytec Cables- El Sewedy, 3Rd laboratory in presence of representative of 3rd
Industrial Zone A3, 10Th Of Ramadan party inspection agency & three engineers of
City Egypt P.O. Box: 1748 - Post Code: SEC for first contract.
10505- , Egypt
WARRANTY::
Contact Person - Mr. Eng Eslam Aly Ten (10) years extended warranty/guarantee in
Phone - +20227599732 respect of defects due to design, manufacture,
Email ID - [email protected] installation & workmanship from the date of
Website - http:// Provisional Acceptance Certificate (PAC) of the
http://www.elsewedycables.com/ first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

ALCATEL Including Joints & Terminations


FRANCE

Website - http://www.alcatel.fr/

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan Including Joints & Terminations

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

DAINICHI-NIPPON CABLES Including Joints & Terminations


(MITSUBISHI)
JAPAN

2. 1 Page 33 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DEMIRER KABLO
TURKEY

Demirer Kablo, Tesisleri San. Ve Tic


A.S. 4 Eylul Mahallesi Ismet Inonu
Caddesi No. 279 Bozuyuk/ Bilecik-
Turkey

Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=

FURUKAWA ELECTRIC CO. LTD. Including Joints & Terminations


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

SUDKABEL PREVIOUSLY ABB.


GERMANY Including Joints & Terminations

Website - http://
http://www.suedkabel.de/index e.htm

FUJIKURA CABLES Including Joints & Terminations


JAPAN

Website - http://www.ffcpg.com.my

MKM Including Joints & Terminations


HUNGARY

Email ID - lang=en
Website -
http://www.mkm-?mediline.de/index.ph
p/edv-und-software-?entwicklung/mkm
-computer-network-?ungarn?lang=en?

DRAKA NK Including Joints & Terminations


FINLAND

Website - http://www.draka.com/

2. 1 Page 34 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JEDDAH CABLE CO. XLPE Cable Type tested in 2010 Based on S&SD letter# 16-06823-30504401
Saudi Arabia 1x1200mm² Report # TDT dated August 14, 2016, the manufacturer is
1002-10 prequalified for XLPE Insulated Power Cable as
Plant -jeddah , 69 kV confirming to SEC specification # 11-TMSS-01,
Rev.0, with the following condition:
Po Box 31248 , Jeddah 21497 Jeddah ,
Saudi Arabia • Ten (10) years extended warranty for XLPE
Power Cable from the date of PAC of the turnkey
jeddah project in case of contract award and date of
delivery in case of direct material supply order,
Contact Person - Mr. Alaa Dandachi , as confirmed by the manufacturer through letter
Mohammad Said Minkara #NIL dated August 14, 2016.
Phone - +966-126360770, 0541462998
Email ID -
[email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.cables.energya.com

Total = 13

CONDUCTOR, INSULATED
2. 2
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE, 110 TO 132 kV Applicable Standards: 11-TMSS-02

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Tests performed at: TAIHAN ELECTRIC WIRE COMPANY Manufacture
KOREA, Republic of Co., Ltd. Branch KEMA shall perform a system type test for HV optimized
P. O. Box 300201, Netherlands (Mar design as per National Grid SA 11-TMSS-02,
Plant -Dangjin Factory Riyadh 11372, Office No. 1995, Dec Rev.02 Cable
18, Commercial Complex 2009 & June 2013)
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected]
Phone - +82 2 316 9190
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.taihan.com

2. 2 Page 35 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY CABLES 132KV, 1x1200mm2 Optimized Design Type Tests PQ Letter


Saudi Arabia Cu/XLPE Power Cable successfully
completed at KEMA Based on S&SD letter # 20-00310-30504401
Plant -Yanbu, Saudi Arabia Laboratories – dated January 29, 2020, the manufacturer is
Netherlands, Test prequalified for 132kV, 1CX1200mm2 XLPE
P.O Box 31670 Yanbu Al Sinaiyah report No. 1780-18 Power Cables (Optimized Design) as confirming
41912, Saudi Arabia and Prequalification to National Grid SA specification # 11-TMSS-02
test at FGH – rev.02, with the following conditions:
Contact Person - Hassan A. Hassan, Manheim, Germany,
Maher Mohamed Test Report No. H WARRANTY
Phone - Tel : +966 14 3570166, Mobile: 20001.
+966 540069254, Fax : +966 Ten (10) years extended warranty from the date
143572223 of PAC of the first turnkey project (in case of
Email ID - [email protected] contract award) or date of first delivery (in case
[email protected] of direct material supply order), as confirmed,
Contact Person Email ID - through their Letter #Nil dated December 21,
[email protected] 2016, shall be applicable for the equipment to be
[email protected] supplied to SEC/National Grid SA.
Website -
http://www.elsewedyelectric.com/FE/C
ommon/Companies.aspx?ID=27&g=3

2. 2 Page 36 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JEDDAH CABLE CO. 1x1200mm2 (132kV) HV Optimized Type Tests PQ Letter


Saudi Arabia Design successfully Based on S&SD Letter # 18-02714-01-30504401
completed at dated July 16, 2018. JEDDAH CABLE Co. -Rabigh
Plant -RABIGH 1x2500mm2 (132kV) HV Optimized DNV-GL (KEMA) – plant is prequalified for 132kV, 1x1200 mm2
Design Netherland testing CU/XLPE/CWS/LAT/HDPE Cables HV Optimized
Exit 294, Rabigh Industrial area, Rabibh Laboratory Report Design and Letter # 20-0954-30504401 dated
K.S.A #1113-18 , Report May 14, 2020, JEDDAH CABLE Co. -Rabigh plant
#1102-20 and is prequalified for 132kV, 1x2500 mm2
RABIGH Report #1329-19 CU/XLPE/CWS/LEAD/HDPE Cables HV Optimized
Design as conforming to National Grid SA
Contact Person - Mr. Alaa Dandachi, specification # 11-TMSS-02, Rev.02 with the
Mohammad Said following conditions:
Phone - 012 636 0770 , 0541462998
Contact Person Email ID - WARRANTY
[email protected], Ten (10) years extended warranty/guaranty from
[email protected] - the date of (PAC) of the Turnkey project (In case
Website - www.cables.energya.com of contract award) and from the date of delivery
for the direct material supply order. The
guarantee/warranty shall be applicable from first
project and shall cover all the cost of materials
and labor as per warranty/guarantee of materials
and workmanship and subsequently reduced
yearly in case of future project award. This was
confirmed in writing by Jeddah cable. Co. through
their letter # nil dated # nil.

2. 2 Page 37 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SAUDI CABLE 1x 1200 mm2 Tests performed at: PQ Letter


Saudi Arabia 1x 2000 mm2 KEMA Based on S&SD letter # 15-00585-01-30504401
110 kV Netherlands (July dated February 10, 2015, the manufacturer is
Plant -Jeddah, Saudi Arabia 2014 to prequalified for 110/115 / 132KV, 1X1200mm²
Optimized 1X 2500 mm² CU/XLPE Dec, 2014) CU/XLPE Power Cable as conforming to National
Saudi Cable Company 132kV Report # TIC Grid SA specification # 11-TMSS-02.
P.O. BOX 4403 Jeddah 21491 1041-14
Industrial Area-Jeddah, Saudi Arabia PQ Letter
Type Tests Based on S&SD letter # 21-00637-30504401
Fax Number: +966 12 637 9877 conducted in IPH dated May 20, 2021, the manufacturer is
Berlin –Germany prequalified for HV Power Cables 132KV
Jeddah from 10/08/2020 to ,1X2500mm2 XLPE Optimized Design confirming
17/03/2021. IPH to National Grid SA specification # 11-TMSS-02
Contact Person - Ammar R. Qari Type tests report # with the following conditions:
Phone - +966 12 608 7666 11293-20-478-1 &
Email ID - [email protected] , SGS Type Test WARRANTY
[email protected] Report # 01.15013 Ten (10) years extended warranty from the date
Contact Person Email ID - Rev. 5 of PAC of the first turnkey project (in case of
[email protected] contract award) or date of first delivery (in case
Website - www.saudicable.com of direct material supply order), as confirmed,
through their Letter No. Nil dated 4th May, 2021
shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

2. 2 Page 38 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RIYADH CABLES 110 TO 132kV, Tests performed at: Based on S&SD letter # 16-04560-30504401
Saudi Arabia 1x2500mm2 KEMA dated June 12, 2016, the manufacturer is
Netherlands (Jan. prequalified for XLPE cable 132KV,as
Plant -Riyadh Optimized Design HV Cable 132KV, 2014) conforming to National Grid SA specification #
1X1200mm². Report # TIC 11-TMSS-02, Rev.01.
P.O. Box 26862- Riyadh, 11496 Riyadh 1489-13
, Saudi Arabia HV Optimized Design Cable 132kV, PQ Letter
2nd Industrial City, Al Kharj Road, street 1X2500mm² CU/XLPE Type /Special tests Based on S&SD letter# 22-01910-30504401
No. 175, 3rd Lane Zone D. Riyadh, were successfully dated Jan 8 2023, the manufacturer is
Kingdom of Saudi Arabia conducted along prequalified for Optimized Design HV Cable
with following cable 132KV, 1X2500mm², CU/XLPE as confirming to
Contact Person - Mr. Dr. Abdulmohsen accessories from National Grid SA specification # 11-TMSS-02,
Aliheraish – Vice Executive Director; Brugg Cables at with the following conditions:
Mr. Mohammad Al-Shmoury, KINECTRIC –
Phone - +966 11 2650850 Ext:238 ; Canada. Report No:
+966 11 2651415 K-423363 WARRANTY
Email ID - [email protected]; RC-0000-R0 & SGS Ten (10) years extended warranty from the date
[email protected]; Inspection report # of PAC of the first turnkey project (in case of
[email protected] 01.14189 Rev.0 & contract award) or date of first delivery (in case
Website - KEMA Tests on Joint of direct material supply order), as confirmed,
http://www.riyadh-cables.com/ Outer Protection – through their Letter No. TMN-09/0099 dated
Extract of Report TIC 7/09/2023 shall be applicable for the equipment to
1012-14: be supplied to SEC/National Grid SA.
I. Porcelain Insulated
Outdoor Sealing End
from Brugg Cables -
Type # TE 1.170-01
II. SF6 Gas Insulated
Sealing End from
Brugg Cables - Type
#
TF 1.170-12
III. Insulating Joint
from Brugg Cables -
Type # MPAP
1.145-33

For Optimized
Design HV Cable
132KV, 1X1200mm²:
DNV.GL/KEMA
Laboratories

2. 2 Page 39 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Arnhem Type Test


Report # 1360-18,
1371-18 & 1814-18
Dated March 27,
2019.

Independent testing
laboratory
KEMA/DNV.GL –
Netherland Lab,
KEMA report #
2030-22 & 1143-22
dated 18-24 Aug
2022 , & SGS report
# 01.15307 Rev.2
dated 23 Aug 2022.

LS PREVIOUSLY LG;
SOUTH KOREA
LS Manufacture shall perform a system type test
Website - http://www.lscable.com/ for HV optimized design as per National Grid SA
11-TMSS-02, Rev.02 Cable

2. 2 Page 40 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DUBAI CABLE CO. HV Optimized Design Cable 132kV, Type test conducted PQ Letter
United Arab Emirates 1X1200mm² CU/XLPE Power Cable in KEMA DNV-GL – Based on S&SD Letter # 22-01319-30504401
Netherland, Lab dated January 02, 2022,Manufacturer is
P.O.Box 683, Dubai - U.A.E Report No.1600-20 pre-qualified for POWER CABLE, XLPE
dated 05/05/2021 INSULATED, COPPER CONDUCTOR, SINGLE
Contact Person - Mr. Ahmed Abou SGS Report – Type CORE, 110 TO 132 kV as conforming to National
Elenien Test Report no. Grid SA Specification # 11-TMSS-02, Rev.02 with
Phone - (+9714) 815 8600 01.15032 Rev.5 the following conditions:
Email ID - [email protected] dated 03/06/2021
Contact Person Email ID - WARRANTY
[email protected], Short Circuit Test Ten (15) years extended warranty from the date
[email protected], conducted in KEMA of PAC of the first turnkey project (in case of
[email protected] DNV-GL – contract award) or date of first delivery (in case
Website - www.ducab.com Netherland, Lab of direct material supply order), as confirmed,
Report No.1473-20 through their Letter No. SE211109FC-2 dated
dated 05/05/2021 November 09, 2021 shall be applicable for the
SGS Report – Short equipment to be supplied to SEC/National Grid SA.
Circuit Test Report
no. 01.15032.13
Rev.02

Pre-Qualification
Test conducted in
KEMA DNV-GL –
Netherland, Lab
Report No. 1601-20
dated 06/05/2021
SGS Report –
Pre-Qualification
Test Report no.
01.15047 Rev.02
dated 03/06/2021.

2. 2 Page 41 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY EGYTECH CABLE CO. XLPE 1x1200mm2 Report # 09-1026 PQ Letter


EGYPT 110 kV, 115 kV & Based on S&SD letter# 15-09015-30504401
132 kV dated November 2, 2015, it is pre-qualified for
Egytec Cables- El Sewedy, 3Rd 1x2500mm2 132kV 132kV, 1x2500mm² CU/XLPE/CWS /LAT/HDPE
Industrial Zone A3, 10Th Of Ramadan Power Cable as confirming to National Grid SA
City Egypt P.O. Box: 1748 - Post Code: specification # 11-TMSS-02, with the following
10505- , Egypt condition:

Contact Person - Mr. Eng Eslam Aly WARRANTY:


Phone - +20227599732 Ten (10) years extended warranty/guarantee in
Email ID - [email protected] respect of defects due to design, manufacture,
Website - http:// installation & workmanship from the date of
http://www.elsewedycables.com/ Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

BRUGG 110 kV to 132 kV. Tests performed at: NAM. GIS termination, Transformer Termination,
SWITZERLAND KEMA Outdoor termination, Cross bonding & Straight
Netherlands Through Joints - XLPE Cables 16 Models of XLPE
5201 Brugg Switzerland,28 Ch5201 Report # TDT cable
Brugg Switzerland, 3148-10 (2011)
70851907-TDT-09-6 BRUGG CABLE Manufacture shall perform a
Contact Person - Mr. Amr Soudi; 9942A system type test for HV optimized design as per
Regional Sales Manager (2009) & TIC National Grid SA 11-TMSS-02, Rev.02 Cable
Contact Person Email ID - 1012-14(2014
[email protected],
[email protected]
Website - www.bruggcables.com

2. 2 Page 42 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan
J-POWER SYSTEM COPP Manufacture shall
Contact Person - Shiro Nomura & Mr. perform a system type test for HV optimized
Amjad Abdelaziz design as per National Grid SA 11-TMSS-02,
Contact Person Email ID - Rev.02 Cable
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

DAINICHI-NIPPON CABLES DAINICHI-NIPPON CABLE Manufacture shall


(MITSUBISHI) perform a system type test for HV optimized
JAPAN design as per National Grid SA 11-TMSS-02,
Rev.02 Cable

DEMIRER KABLO SSC Jeddah Tests performed at: DEMIRER KABLO Manufacture shall perform a
TURKEY PO Box 4403 , Jeddah XLPE 1x2500 mm2, Kinectrics Canada system type test for HV optimized design as per
Saudi Arabia 132 kV (Sep. 2013 to Sep. National Grid SA 11-TMSS-02, Rev.02 Cable
Demirer Kablo, Tesisleri San. Ve Tic 2014)
A.S. 4 Eylul Mahallesi Ismet Inonu Report # 423151
Caddesi No. 279 Bozuyuk/ Bilecik-
Turkey

Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=

FURUKAWA ELECTRIC CO. LTD. FURUKAWA ELECTRIC Manufacture shall perform


JAPAN a system type test for HV optimized design as
per National Grid SA 11-TMSS-02, Rev.02 Cable
Website - http://
http://www.furukawa.co.jp/english/ind
ex.

2. 2 Page 43 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SUDKABEL PREVIOUSLY ABB.


GERMANY
SUDKABEL Cable Manufacture shall perform a
Website - http:// system type test for HV optimized design as per
http://www.suedkabel.de/index e.htm National Grid SA 11-TMSS-02, Rev.02 Cable

FUJIKURA FUJIKURA Manufacture shall perform a system


JAPAN type test for HV optimized design as per National
Grid SA 11-TMSS-02, Rev.02 Cable
Website - http://www.ffcpg.com.my/

DRAKA NK DRAKA Manufacture shall perform a system type


FINLAND test for HV optimized design as per National Grid
SA 11-TMSS-02, Rev.02 Cable
Website - http://www.draka.com/

JEDDAH CABLE CO. 1x1200mm2 All models type Based on TS&SD Letter #10-02784-01-03032301
Saudi Arabia (110kV & 132kV) tested at: dated October 10,2014 and S&SD Letter
KEMA Netherlands #14-04876-01-30504401 dated july 16 2014. It is
Plant -jeddah 1x2000mm2 (2010, prequalified for 132 kV , 1x2500mm2
(115kV & 132kV) 2012, 2013 & 2014) CU/XLPE/CWS/LAT/HDPE Power Cable as
Po Box 31248 , Jeddah 21497 Jeddah , Report # TIC confirming to N ational Grid Specification #
Saudi Arabia 1x2500mm2 132kV 1065-12, TIC 11-TMSS-02 Rev.1 with the following condition
1002-13, TDT
jeddah 1001-10, TIC Ten ( 10) years extended wararanty for XLPE
1072-12, TIC Power cable from the date of PAC of the turnkey
Contact Person - Mr. Alaa Dandachi , 1013-14 project in case of contract award or date of
Mohammad Said Minkara delivery in case of direct material supply order.
Phone - +966-126360770, 0541462998 This was confirmed in writing by Jeddah cable.
Email ID - Co. through letter #nil dated 26th June 2006.
[email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.cables.energya.com

2. 2 Page 44 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL SYSTEMS HV Optimized Design Cable 132kV, *Type test PQ Letter
Saudi Arabia 1X1200mm² CU/XLPE performed in Based on S&SD letter # 18-4748-01-30504401
DNV-GL (KEMA) – dated December 31, 2018, the manufacturer is
Plant -3Rd Industrial Area, Al Kharaj Netherland testing prequalified for Optimized Design HV Cable
Road, Riyadh Saudi Arabia laboratory Report # 132KV, 1X1200mm² CU/XLPE as conforming to
1567-18, 1676-17. National Grid SA specification # 11-TMSS-02,
Po Box 301 , Riyadh 11411 , North Righ Rev.02, with the following condition:
Road Between Exit 5 & 6 Riyadh , • Al Fanar Cables shall preform a system type
Saudi Arabia test for HV Optimized Design of 1x2500 mm²,
132kV Cable.
Riyadh
WARRANTY
Contact Person - Sultan Alghamdi " VIP Ten (10) years extended warranty in respect of
key Account Manegr "; Saleh the defects due to design, manufacturing,
Almehaijeen "Projects Sales Engineer " installation and workmanship from the date of the
Phone - 920006111 Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - 132KV HV Cable *Independent testing first project (in case of contract award) and from
[email protected]; 1x1200mm2 XLPE laboratory the date of first delivery in case of direct material
[email protected] KEMA/DNV.GL – supply order shall be provided as confirmed by
Website - www.alfanar.com Netherland Lab the manufacturer through their letter
during 22nd to 27th MPQ102382-ClassI(a)-2018 dated 20/12/2018.
July 2015 , KEMA
report # 1241-15 &
1242-15 dated
16.09.2015 & SGS PQ Letter
report # 01.13864 •Based on S&SD letter# 17-00831-1-30504401
Rev.1 dated dated February 14, 2017, the manufacturer is
04.08.2015. prequalified for 1x1200MM2 XLPE High Voltage
Cables for 132KV as confirming to SEC
specification # 11-TMSS-02, Rev.1, with the
following condition:

WARRANTY
•Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter
MPQ102382-ClassI(a)-2016 dated 07/02/2017.

2. 2 Page 45 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Bahra Advance Cable Manufacture Co. 132KV, 1x1200mm2 Optimized Design Type test & long PQ Letter
Ltd Cu/XLPE Power Cable duration Based on S&SD letter# 19-01209-01-30504401
Saudi Arabia prequalification test dated April 29, 2019, the manufacturer is
1x2500mm2 (132kV) HV Optimized performed in prequalified for 132KV, 1x1200mm2 Optimized
Po Box 5989 Jeddah 21432 , Saudi Design DNV.GL/KEMA Design Cu/XLPE Power Cable as confirming to
Arabia Testing Laboratories National Grid SA specification # 11-TMSS-02,
Arnhem Netherland. with the following conditions:
Contact Person - Mr. Loai Taha Al-Bar, Type Test Date:-
Sale Manager 28.09.2018 to Bahra Advanced Cable Manufacture Co. Ltd –
Phone - +966-2-591-1115 19.03.2019 Jeddah, KSA shall perform a system type test for
Email ID - [email protected] Long Duration HV optimized design of 1x2500mm2, 132kV Cable
Prequalification Test
Date:- 03.05.2018 – WARRANTY
30.01.2019 Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
DNV.GL/KEMA contract award) or date of first delivery (in case
Laboratories of direct material supply order), as confirmed,
Arnhem Netherland through their Letter No. 1030/BH/2017 dated
Type Test Report, 22/03/2017 shall be applicable for the equipment
Short Circuit Test to be supplied to SEC/National Grid SA.
Report & Long
Duration
Prequalification Test PQ Letter
Report # 1819-18 Based on S&SD letter #22-01130-30504401
dated April 2, 2019, dated August 31, 2022, the manufacturer is
2333-18 dated prequalified for POWER CABLE, XLPE
February 02, 2019 & INSULATED, COPPER CONDUCTOR, SINGLE
1815-18 dated CORE, 110 TO 132 kV type: 76/132 (145) KV
March 22, 2019 1x2500mm² CU/XLPE/LC/HDPE HV Power Cable
respectively. (Optimized Design) as confirming to National Grid
SA specification # 11-TMSS-02, with the
Type test conducted following conditions:
in KEMA
Lab-Netherland from WARRANTY
31st May to 10th Ten (10) years extended warranty from the date
June 2022 of PAC of the first turnkey project (in case of
Type Test Reports # contract award) or date of first delivery (in case
2161-22, 1123-22 & of direct material supply order), as confirmed,
1122-22 through their Letter #Nil dated August 29, 2022,
SGS Report # shall be applicable for the equipment to be
01.15208 Rev.02 supplied to SEC/National Grid SA.

2. 2 Page 46 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 19

CONDUCTOR, INSULATED
2. 3
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE, 230 kV Applicable Standards: 11-TMSS-02

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Tests performed at: WARRANTY:
KOREA, Republic of Co., Ltd. Branch KEMA Ten (10) years extended warranty/guarantee in
P. O. Box 300201, Netherlands respect of defects due to design, manufacture,
Plant -Dangjin Factory Riyadh 11372, Office No. installation & workmanship from the date of
18, Commercial Complex Provisional Acceptance Certificate (PAC) of the
317, Simin Daero, Dongan-gu Building, King Abdulaziz first turnkey project in case of contract award or
Rd. Exit 5, Kingdom of date of first delivery in case of direct material
Anyang-si Saudi Arabia supply order.
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected]
Phone - +82 2 316 9190
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.taihan.com

JEDDAH CABLE CO. 1x2500mm2 CU/XLPE, 230kV Type test performed PQ Letter
Saudi Arabia in DNV-GL (KEMA) – Based on S&SD letter # 18-03331-02-30504401
Netherland testing dated September 18, 2018 Jeddah Cable Co ,
Plant -RABIGH laboratory, report # Rabigh, Saudi Arabia is pre-qualified for 230kV,
1377-16 1x2500mm2 CU/XLPE Cables as conforming to
Exit 294, Rabigh Industrial area, Rabibh Prequalification Test National Grid SA specification # 11-TMSS-02
K.S.A performed in
DNV-GL (KEMA) – Warranty
RABIGH Netherland testing Ten (10) years extended warranty/guaranty
laboratory, report # from the date of (PAC) of the Turnkey project (In
Contact Person - Mr. Alaa Dandachi, 1404-18 case of contract award) and from the date of
Mohammad Said delivery for the direct material supply order. The
Phone - 012 636 0770 , 0541462998 guarantee/warranty shall be applicable from first
Contact Person Email ID - project and shall cover all the cost of materials
[email protected], and labor as per warranty/guarantee of materials
[email protected] - and workmanship and subsequently reduced
Website - www.cables.energya.com yearly in case of future project award. This was
confirmed in writing by Jeddah cable. Co. through
their letter # nil dated # nil.

2. 3 Page 47 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RIYADH CABLES 230KV Cable CU/XLPE, 1X2500sqmm Type test performed PQ Letter
Saudi Arabia in DNV-GL (KEMA) –
Netherland testing Based on S&SD Letter # 22-01397-30504401
Plant -Riyadh laboratory, report # dated 20.10.2022, the manufacturer is
1821-18 & 2123-18, prequalified for 230KV Cable as conforming to
P.O. Box 26862- Riyadh, 11496 Riyadh Prequalification Test National Grid SA specification # 11-TMSS-02,
, Saudi Arabia performed in with the following conditions:
2nd Industrial City, Al Kharj Road, street DNV-GL (KEMA) –
No. 175, 3rd Lane Zone D. Riyadh, Netherland testing Warranty:
Kingdom of Saudi Arabia laboratory, report # Ten (10) years extended warranty from the date
1702-19 for 380 kV, of PAC of the first turnkey project (in case of
Contact Person - Mr. Dr. Abdulmohsen Extended to cover contract award) or date of first delivery (in case
Aliheraish – Vice Executive Director; 230 kV. of direct material supply order). as confirmed,
Mr. Mohammad Al-Shmoury, through their letter No. TMN-10/0665, dated
Phone - +966 11 2650850 Ext:238 ; October 10, 2020, shall be applicable for the
+966 11 2651415 equipment to be supplied to SEC/National Grid SA.
Email ID - [email protected];
[email protected];
[email protected]
Website -
http://www.riyadh-cables.com/

SAUDI CABLE XLPE 1x 630 mm2 , Tests performed at: PQ Letter


Saudi Arabia 1 x 2500 mm2 KEMA Based on TS&SD letter# 09-01366-03032301
230 kV Netherlands (Aug. dated 10th. May 2009, it is pre-qualified with the
Plant -Jeddah, Saudi Arabia 2010 to following conditions:
June 2011& March
Saudi Cable Company 2011 to WARRANTY:
P.O. BOX 4403 Jeddah 21491 Aug. 2012). Ten (10) years extended warranty/guarantee in
Industrial Area-Jeddah, Saudi Arabia Report # respect of defects due to design, manufacture,
TIC-1010-11, & installation & workmanship from the date of
Fax Number: +966 12 637 9877 TIC1030-12, TIC Provisional Acceptance Certificate (PAC) of the
2535-12 first turnkey project in case of contract award or
Jeddah date of first delivery in case of direct material
supply order as confirmed by the manufacturer
Contact Person - Ammar R. Qari through their letter no.nil, dt: 12 may, 2008..
Phone - +966 12 608 7666
Email ID - [email protected] ,
[email protected]
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

2. 3 Page 48 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES & SYSTEMS LTD. PREVIOUSLY LG;


SOUTH KOREA
WARRANTY:
Contact Person - Mr. H.S.JO (General Ten (10) years extended warranty/guarantee in
Manager) Mr. Young Min Seo respect of defects due to design, manufacture,
Email ID - [email protected] installation & workmanship from the date of
Website - http://www.lscable.com/ ? Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

BRUGG CONDITION:
SWITZERLAND All type/design and routine/sample tests shall be
conducted at SEC approved independent
Contact Person - Mr. Amr Soudi; laboratory in presence of representative of 3rd
Regional Sales Manager party inspection agency & three engineers of
Phone - +41 79 9135155 SEC for first contract.
Email ID -
[email protected] WARRANTY:
Contact Person Email ID - Ten (10) years extended warranty/guarantee in
[email protected] respect of defects due to design, manufacture,
Website - www.bruggcables.com installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

2. 3 Page 49 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN

DEMIRER KABLO
TURKEY

Demirer Kablo, Tesisleri San. Ve Tic


A.S. 4 Eylul Mahallesi Ismet Inonu
Caddesi No. 279 Bozuyuk/ Bilecik-
Turkey

Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=

FURUKAWA ELECTRIC CO. LTD.


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

SUDKABEL PREVIOUSLY ABB.


GERMANY

Website - http://
http://www.suedkabel.de/index e.htm

FUJIKURA
JAPAN

Website - http://www.ffcpg.com.my/

Total = 12

CONDUCTOR, INSULATED
2. 4
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE 380 kV Applicable Standards: 11-TMSS-02

2. 4 Page 50 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution 1x2500mm2 Tests performed at: PQ Letter
KOREA, Republic of Co., Ltd. Branch CWS Type, KEMA Based on S&SD letter # 14-08139-01-30504401
P. O. Box 300201, 380 kV with the following drawing Netherlands (Jan. dated: January 07, 2015, the manufacturer is
Plant -Dangjin Factory Riyadh 11372, Office No. numbers: 2014 to prequalified to supply 380kV 1x2500mm2 CWS
18, Commercial Complex May, 2014) Type power cables:
317, Simin Daero, Dongan-gu Building, King Abdulaziz - Power cable: Report # TIC
Rd. Exit 5, Kingdom of TXCCD-3802500-130501. 3094-14 WARRANTY:
Anyang-si Saudi Arabia Ten (10) years extended warranty in respect of
+966 11 410 1773 the defects due to design, manufacturing,
Contact Person - Jang Hee Lee [email protected] installation and workmanship from the date of the
Phone - +82 2 316 9190 Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] first turnkey project (in case of contract award)
Contact Person Email ID - or from the date of first delivery in case of direct
[email protected] material supply order shall be provided as
Website - www.taihan.com confirmed by the manufacturer through their
letter # Nil dated September 02, 2014.

2. 4 Page 51 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JEDDAH CABLE CO. • 1x2500mm2 CU/XLPE, 380kV For 380kV, PQ Letter


Saudi Arabia • 1x2500mm2 CU/XLPE/SAS/HDPE, 1x2500mm2 Based on S&SD letter # 18-03331-02-30504401
380kV CU/XLPE Cables: dated September 18, 2018 Jeddah Cable Co ,
Plant -RABIGH Type test performed Rabigh, Saudi Arabia is pre-qualified for 380kV,
in DNV-GL (KEMA) – 1x2500mm2 CU/XLPE Cables as conforming to
Exit 294, Rabigh Industrial area, Rabibh Netherland testing National Grid SA specification # 11-TMSS-02.
K.S.A laboratory, report
#1184-16 Based on S&SD letter # 22-00267-30504401
RABIGH Prequalification Test dated March 08, 2022 Jeddah Cable Co , Rabigh,
performed in Saudi Arabia is pre-qualified for 380kV,
Contact Person - Mr. Alaa Dandachi, DNV-GL (KEMA) – 1x2500mm2 CU/XLPE/SAS/HDPE Cables as
Mohammad Said Netherland testing conforming to National Grid SA specification #
Phone - 012 636 0770 , 0541462998 laboratory, report 11-TMSS-02.
Contact Person Email ID - #1406-18
[email protected], Warranty
[email protected] - For 380kV,
Website - www.cables.energya.com 1x2500mm2 For 380kV, 1x2500mm2 CU/XLPE Cables:
CU/XLPE/SAS/HDPE Ten (10) years extended warranty/guaranty from
Cables: the date of (PAC) of the Turnkey project (In case
Type test performed of contract award) and from the date of delivery
satisfactory in for the direct material supply order. The
DNV-GL (KEMA) – guarantee/warranty shall be applicable from first
Netherland resting project and shall cover all the cost of materials
laboratory, report and labor as per warranty/guarantee of materials
#1603-21 dated 05 and workmanship and subsequently reduced
July to 01 December yearly in case of future project award. This was
2021 & 1607-21 confirmed in writing by Jeddah cable. Co. through
dated 26 October to their letter # nil dated # nil.
09 November, 2021
(Electrical and Non For 380kV, 1x2500mm2 CU/XLPE/SAS/HDPE
electrical tests) and Cables:
report #2358-21 Ten (10) years extended warranty from the date
dated 05 to 09 of PAC of the first turnkey project (in case of
November, 2021 contract award) or date of first delivery (in case
(short circuit test). of direct material supply order). as confirmed,
through their letter No. JCC-EP-TT-21-004-03,
dated April 22, 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

2. 4 Page 52 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ILJIN ELECTRIC CO. LTD. Dopa Co. for Trading and 380kV XLPE Cable 1x2500mm² Based on S&SD letter# 16-2299-02-30504401
SOUTH KOREA industry CU/XLPE/LEAD/HDPE dated May 02, 2016, it is prequalified for380kV
Al Nuzha District Riyadh, XLPE Cable 1x2500mm² CU/XLPE/LEAD/HDPE as
Plant -South KOREA Saudi Arabia P.O. Box conforming to National Grid SA Material
87017 Code No. 11462 Specification 11-TMSS-02, Rev 01 with the
905-64, Mannyeon-ro, Hwaseong-si, Mr. Abdullah Alabdullah following conditions:
Gyeonggi-do Email /
alabdullah@dopacompan • Ten (10) years extended warranty from the
Contact Person - Mr. Tony Lim, Mr. y.com date of PAC of the turnkey project in case of
Daniel Park TEL / (+966) 11 2694609 contract award and date of delivery in case of
Phone - +82-2-707-9253 , Mobile / (+966) direct material supply order, as confirmed by the
Email ID - [email protected]; 504122831 manufacturer through letter # ILJHC-160412 A
[email protected] dated 12/04/2016.

RIYADH CABLES 1X2500 mm2 CU/XLPE, 380kV Type test performed PQ Letter:
Saudi Arabia in DNV-GL (KEMA) –
Netherland testing Based on S&SD letter# 20-00230-01-30504401
Plant -Riyadh laboratory, report # dated January 30, 2020, the manufacturer is
1821-18 & 2123-18, prequalified for EHV Cable 380kV 1X2500mm2,
P.O. Box 26862- Riyadh, 11496 Riyadh Prequalification Test CU/XLPE, as confirming to National Grid SA
, Saudi Arabia performed in specification # 11-TMSS-02, with the following
2nd Industrial City, Al Kharj Road, street DNV-GL (KEMA) – conditions:
No. 175, 3rd Lane Zone D. Riyadh, Netherland testing
Kingdom of Saudi Arabia laboratory, report # WARRANTY:
1702-19
Contact Person - Mr. Dr. Abdulmohsen Ten (10) years extended warranty from the date
Aliheraish – Vice Executive Director; of PAC of the first turnkey project (in case of
Mr. Mohammad Al-Shmoury, contract award) or date of first delivery (in case
Phone - +966 11 2650850 Ext:238 ; of direct material supply order), as confirmed,
+966 11 2651415 through their Letter No. TNN-02/1001 dated
Email ID - [email protected]; January 22, 2020 shall be applicable for the
[email protected]; equipment to be supplied to SEC/National Grid SA.
[email protected]
Website -
http://www.riyadh-cables.com/

2. 4 Page 53 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES & SYSTEMS LTD. Type/Model: Tests performed at PREVIOUSLY LG;


SOUTH KOREA KEMA
380 kV cable Netherlands (Aug, PQ Letter
Contact Person - Mr. H.S.JO (General 1x2500 mm2, CU/XLPE/LEAD/PE 2014 to Based on S&SD letter # 15-3193-30504401 dated
Manager) Mr. Young Min Seo Dec, 2014) May 03, 2015, the manufacturer is prequalified to
Email ID - [email protected] Test Report Nos. supply the Power Cables with the specified
Website - http://www.lscable.com/ ? 1066-14 & TIC designations only:
1564-14
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

BRUGG CONDITION:
SWITZERLAND All type/design and routine/sample tests shall be
conducted at SEC approved independent
5201 Brugg Switzerland,28 Ch5201 laboratory in presence of representative of 3rd
Brugg Switzerland, party inspection agency & three engineers of
SEC for first contract.
Contact Person - Mr. Amr Soudi;
Regional Sales Manager WARRANTY:
Contact Person Email ID - Ten (10) years extended warranty/guarantee in
[email protected], respect of defects due to design, manufacture,
[email protected] installation & workmanship from the date of
Website - www.bruggcables.com Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

2. 4 Page 54 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NEXANS Benoit Rollet Tests performed PQ Letter


BELGIUM Phone - (19-12-2013 to Based on S&SD letter # 14-07330-030504401,
+33-6-14-99-00-54 16-04-2014) dated 22/10/2014, it is prequalified for 380kV
Charleroi , Belgium Email - XLPE Cables with following condition:
[email protected]
m WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter # Nil, dt:.12/02/2013

NKT, GERMANYTEMPELHOFER WEG


39/41
GERMANY

Tempelhofer Weg 39/41, 10829 Berlin ,


Germany

Contact Person - Mr. Mrs. Patricia Wei


Phone - +49 (0)30 60009 -0
Website - http://www.nktcables.com/

VISCAS FUJIKURA
JAPAN

Website - http://
http://www.viscas.com/e contact.html

2. 4 Page 55 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN

DEMIRER KABLO PQ Letter


TURKEY Based on TS&SD letter 11-01374-03032301
dated April 27, 2011. It is DISQUALIFIED for
Demirer Kablo, Tesisleri San. Ve Tic 380KV XLPE Cable.
A.S. 4 Eylul Mahallesi Ismet Inonu
Caddesi No. 279 Bozuyuk/ Bilecik-
Turkey

Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=

SUDKABEL PREVIOUSLY ABB.


GERMANY

Website - http://
http://www.suedkabel.de/index e.htm

Total = 13

CONDUCTOR, INSULATED
2. 5
POWER CABLE, LPOF, CU, 1-CORE, CABLE –110 kV TO 132 kV Applicable Standards: 11-TMSS-03

2. 5 Page 56 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Rating - 132kV KEMA, Netherlands Including Joints & Terminations
KOREA, Republic of Co., Ltd. Branch July 2000
P. O. Box 300201,
Plant -Dangjin Factory Riyadh 11372, Office No.
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected]
Phone - +82 2 316 9190
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.taihan.com

CANADA WIRE Including Joints & Terminations


CANADA

Website - http://
http://www.transcanadawireandcable.
com

KABEL RHEYDT (AEG) Including Joints & Terminations


GERMANY

SHOWA CABLE Including Joints & Terminations


JAPAN

Website - http://
http://www.swcc.co.jp/eng/index.htm

ALCATEL Including Joints & Terminations


FRANCE

Website - http://www.alcatel.fr/

KABEL WERK BRUGG AG Including Joints & Terminations


SWITZERLAND

Website - http://
http://www.bruggcables.com/index/ind
ex.cfm?page=home&sprache=de

2. 5 Page 57 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NEXAN(CORTALLIOD) Including Joints & Terminations


SWITZERLAND

Website -
http://www.nexans.com/eservice/Navi
gate.nxnavigationRef=
-10&CZ=Corporate

PIRELLI Including Joints & Terminations


ITALY

DATWYLER Including Joints & Terminations


United Kingdom

Website - http://
http://www.daetwyler.net/e/index.htm

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan Including Joints & Terminations

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

DAINICHI-NIPPON CABLES Including Joints & Terminations


(MITSUBISHI)
JAPAN

FURUKAWA ELECTRIC CO. LTD. Including Joints & Terminations


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

2. 5 Page 58 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SUDKABEL PREVIOUSLY ABB


GERMANY
Including Joints & Terminations
Website - http://
http://www.suedkabel.de/index e.htm

FUJIKURA Including Joints & Terminations


JAPAN

Website - http://www.ffcpg.com.my/

LS CABLES PREVIOUSLY LG
SOUTH KOREA
Including Joints & Terminations
Plant -Gumi/Korea

13 F Ls Tower ,127, Ls-Ro,


Dongan-Gu, Anyang-Si, Gyeonggi-Do,
Korea

Contact Person - Jiyup Baik


Phone - +82-544697602
Email ID - [email protected]
Website - http://www.lscns.com

Total = 15

CONDUCTOR, INSULATED
2. 6
POWER CABLE, LPOF, CU, 1-CORE, 230 kV Applicable Standards: 11-TMSS-03

2. 6 Page 59 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Feb. 2006 Including Joints & Terminations.
KOREA, Republic of Co., Ltd. Branch
P. O. Box 300201, CONDITION:
Plant -Dangjin Factory Riyadh 11372, Office No. All type/design and routine/sample tests shall be
18, Commercial Complex conducted at SEC approved independent
317, Simin Daero, Dongan-gu Building, King Abdulaziz laboratory in presence of representative of 3rd
Rd. Exit 5, Kingdom of party inspection agency & three engineers of
Anyang-si Saudi Arabia SEC for first contract.
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected] WARRANTY:
Phone - +82 2 316 9190 Ten (10) years extended warranty/guarantee in
Email ID - [email protected] respect of defects due to design, manufacture,
Contact Person Email ID - installation & workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
Website - www.taihan.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

CANADA WIRE Including Joints & Terminations


CANADA

Website - http://
http://www.transcanadawireandcable.
com

KABEL RHEYDT (AEG) Including Joints & Terminations


GERMANY

ALCATEL Including Joints & Terminations


FRANCE

Website - http://www.alcatel.fr/

2. 6 Page 60 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan Including Joints & Terminations

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

DAINICHI-NIPPON CABLES Including Joints & Terminations


(MITSUBISHI)
JAPAN

FURUKAWA ELECTRIC CO. LTD. Including Joints & Terminations


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

SUDKABEL PREVIOUSLY ABB.


GERMANY
Including Joints & Terminations
Website - http://
http://www.suedkabel.de/index e.htm

FUJIKURA Including Joints & Terminations


JAPAN

Website - http://www.ffcpg.com.my/

Total = 9

CONDUCTOR, INSULATED
2. 7
POWER CABLE, LPOF, CU, 1-CORE,380 kV Applicable Standards: 11-TMSS-03

2. 7 Page 61 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Including Joints & Terminations.
KOREA, Republic of Co., Ltd. Branch
P. O. Box 300201, CONDITION:
Plant -Dangjin Factory Riyadh 11372, Office No. All type/design and routine/sample tests shall be
18, Commercial Complex conducted at SEC approved independent
317, Simin Daero, Dongan-gu Building, King Abdulaziz laboratory in presence of representative of 3rd
Rd. Exit 5, Kingdom of party inspection agency & three engineers of
Anyang-si Saudi Arabia SEC for first contract.
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected] WARRANTY:
Phone - +82 2 316 9190 Ten (10) years extended warranty/guarantee in
Email ID - [email protected] respect of defects due to design, manufacture,
Contact Person Email ID - installation & workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
Website - www.taihan.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

STANDARD TELEFON OG Including Joints & Terminations


KABELFABRIK,
NORWAY

CANADA WIRE Including Joints & Terminations


CANADA

Website - http://
http://www.transcanadawireandcable.
com

KABEL RHEYDT (AEG) Including Joints & Terminations


GERMANY

HITACHI CABLE LTD. Including Joints & Terminations


JAPAN

Website -
http://www.hitachi-?cable.co.jp/en/inde
x.html

2. 7 Page 62 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MITSUBISHI CABLE INDUSTRIES LTD Including Joints & Terminations


JAPAN

Website -
http://www.mitsubishi-cable.co.jp/inde
x e.html

PIRELLI GENERAL Including Joints & Terminations


United Kingdom

SHOWA CABLE Including Joints & Terminations


JAPAN

Website - http://
http://www.swcc.co.jp/eng/index.htm

SIEMENS Including Joints & Terminations


GERMANY

Plant -Berlin. Germany

Freyeslebenstr 1 91058 Erlangen

Contact Person - Mr. Yaser Salih


Phone - +49-9131725216
Email ID - [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

ALCATEL Including Joints & Terminations


FRANCE

Website - http://www.alcatel.fr/

PIRELLI Including Joints & Terminations


ITALY

2. 7 Page 63 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan Including Joints & Terminations

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

DAINICHI-NIPPON CABLES Including Joints & Terminations


(MITSUBISHI)
JAPAN

FURUKAWA ELECTRIC CO. LTD. Including Joints & Terminations


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

FUJIKURA Including Joints & Terminations


JAPAN

Website - http://www.ffcpg.com.my/

2. 7 Page 64 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES PREVIOUSLY LG
SOUTH KOREA
Including Joints & Terminations.
Plant -Gumi/Korea
WARRANTY:
13 F Ls Tower ,127, Ls-Ro, Ten (10) years extended warranty/guarantee in
Dongan-Gu, Anyang-Si, Gyeonggi-Do, respect of defects due to design, manufacture,
Korea installation & workmanship from the date of PAC
of the First turnkey project in case of contract
Contact Person - Jiyup Baik award or date of the First delivery in case of
Phone - +82-544697602 directmaterial supply order.
Email ID - [email protected]
Website - http://www.lscns.com

Total = 16

CONDUCTOR, INSULATED
2. 8
MEDIUM VOLTAGE POWER CABLE -XLPE –13.8 kV Applicable Standards: 11-TMSS-04

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution KEMA, Netherlands Including Joints & Terminations
KOREA, Republic of Co., Ltd. Branch (Nov. 2007)
P. O. Box 300201,
Plant -Dangjin Factory Riyadh 11372, Office No.
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected]
Phone - +82 2 316 9190
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.taihan.com

2. 8 Page 65 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY CABLES Up to 630 mm², 13.8 KV Same for MEDIUM PQ Letter:


Saudi Arabia VOLTAGE POWER Based on S&SD letter # 17-07027-2-30504401
CABLE - XLPE , 33 & dated October 17, 2017, Elsewedy Cables,
Plant -Yanbu, Saudi Arabia 34.5 kV reports Yanbu - KSA is pre-qualified for MV Cables as
• 34.5kV 1x630mm2: conforming to National Grid SA specification #
P.O Box 31670 Yanbu Al Sinaiyah Tests performed at 11-TMSS-04, with the following conditions:
41912, Saudi Arabia KEMA, Netherlands
(August,2017) WARRANTY:
Contact Person - Hassan A. Hassan, Report # 1114-17 Ten (10) years extended warranty/guarantee in
Maher Mohamed • 34.5kV 1x630mm2: respect of defects due to design, manufacture,
Phone - Tel : +966 14 3570166, Mobile: Tests performed at installation and workmanship from the date of
+966 540069254, Fax : +966 KEMA, Netherlands Provisional Acceptance Certificate (PAC) of the
143572223 (August,2017) first turnkey project in case of contract award or
Email ID - [email protected] Report # 1130-17 date of first delivery in case of direct material
[email protected] • 34.5kV 3x500mm2: supply order, as confirmed by the manufacturer
Contact Person Email ID - (Al) Tests performed vide letter # Nil, dated January 11, 2016.
[email protected] at KEMA,
[email protected] Netherlands
Website - (August,2017)
http://www.elsewedyelectric.com/FE/C Report # 1122-17
ommon/Companies.aspx?ID=27&g=3 • 34.5kV 3x500mm2:
(Al) Tests performed
at KEMA,
Netherlands
(August,2017)
Report # 1129-17

2. 8 Page 66 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Gaon Cables CO., LTD. Abdulaziz M. AlSuwaiket MV Power Cable up to 1000 mm² Type Tests PQ letter:
SOUTH KOREA (AlSuwaiket) conducted in KEMA Based on S&SD letter # 18-01986-030504401
AlSuwaiket during 01 to 09 dated May 24, 2018 for Gaon Cables. Gunpo,
Plant -Gunpo +966-13-857-1155 March 2018 Korea is pre-qualified for Medium Voltage Power
[email protected] Report no 01 14440 Cables as conforming to latest National Grid SA
120, LS-ro 45beon-gil, Gunpo-si, om A (by SGS) specification # 11-TMSS-04, with the following
Gyeonggi-do, 15841, Republic of Korea conditions:

Contact Person - 1.SeongJun Kim WARRANTY:


(GAON CABLE CO., LTD.) Ten (10) years extended warranty/guarantee in
Phone - +82-2-6921-3880 respect of defects due to design, manufacture,
Email ID - [email protected] installation and workmanship from the date of
Contact Person Email ID - Provisional Acceptance Certificate (PAC) of the
[email protected] first turnkey project in case of contract award or
Website - www.gaoncable.com date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated April 12, 2016.

SAUDI CABLE
Saudi Arabia

Plant -Jeddah, Saudi Arabia

Saudi Cable Company


P.O. BOX 4403 Jeddah 21491
Industrial Area-Jeddah, Saudi Arabia

Fax Number: +966 12 637 9877

Jeddah

Contact Person - Ammar R. Qari


Phone - +966 12 608 7666
Email ID - [email protected] ,
[email protected]
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

2. 8 Page 67 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL SYSTEMS Type Tests have PQ Letter


Saudi Arabia been successfully Based on S&SD Letter 13-05014-2-3050440
conducted in dated September 08, 2013, it is pre-qualified for
Plant -Riyadh Saudi Arabia KINETRIC-Canada in Insulated Conductor Cable (XLPE) with the
the presence of following condition:
Po Box 301 , Riyadh 11411 ,North Righ National Grid SA
Road Between Exit 5 & 6 Engineers on WARRANTY:
1x630mm2 Ten (10) years extended warranty/guarantee in
Riyadh CU/XLPE/ATA/PVC respect of defects due to design, manufacture,
20/35 KV MV Cable installation & workmanship from the date of
Contact Person - Sultan Alghamdi " VIP during 9th to 22nd Provisional Acceptance Certificate (PAC) of the
key Account Manegr "; Saleh April 2013. first turnkey project in case of contract award or
Almehaijeen "Projects Sales Engineer " However, any MV date of first delivery in case of direct material
Phone - 920006111 Power Cable supply order, as confirmed by the manufacturer
Contact Person Email ID - beyond cable size vide letter#Nil, dt: Mar 10, 2013.
[email protected]; of 630 mm2 to be
[email protected] supplied to
Website - www.alfanar.com SEC/National Grid
SA shall fully type
tested at an
accredited
laboratory in the
presence of National
Grid SA Engineers &
third party inspector.

2. 8 Page 68 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RIYADH CABLES 13.8 KV Tests performed at


Saudi Arabia KSU,
Riyadh KSA (Jan.
Plant -Riyadh 2012)
Report #
P.O. Box 26862- Riyadh, 11496 Riyadh TRC-0011433
, Saudi Arabia
2nd Industrial City, Al Kharj Road, street
No. 175, 3rd Lane Zone D. Riyadh,
Kingdom of Saudi Arabia

Contact Person - Mr. Dr. Abdulmohsen


Aliheraish – Vice Executive Director;
Mr. Mohammad Al-Shmoury,
Phone - +966 11 2650850 Ext:238 ;
+966 11 2651415
Email ID - [email protected];
[email protected];
[email protected]
Website -
http://www.riyadh-cables.com/

LS PREVIOUSLY LG
SOUTH KOREA Including Joints & Terminations

Website - http://www.lscable.com/

DUBAI CABLE CO.


United Arab Emirates

P.O.Box 683, Dubai - U.A.E

Contact Person - Mr. Ahmed Abou


Elenien
Phone - (+9714) 815 8600
Email ID - [email protected]
Contact Person Email ID -
[email protected],
[email protected],
[email protected]
Website - www.ducab.com

2. 8 Page 69 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY EGYTECH CABLE CO.


EGYPT

Egytec Cables- El Sewedy, 3Rd


Industrial Zone A3, 10Th Of Ramadan
City Egypt P.O. Box: 1748 - Post Code:
10505- , Egypt

Contact Person - Mr. Eng Eslam Aly


Phone - +20227599732
Email ID - [email protected]
Website - http://
http://www.elsewedycables.com/

OMAN CABLE INDUSTRIES Ref# is 08-02531/01-0303230 dated 08/ 11/2008


Oman No Accessories are pre-qualified

muscat

Website -
http://www.omancables.com/

JEDDAH CABLE CO.


Saudi Arabia

Plant -jeddah

Po Box 31248 , Jeddah 21497 Jeddah ,


Saudi Arabia

jeddah

Contact Person - Mr. Alaa Dandachi ,


Mohammad Said Minkara
Phone - +966-126360770, 0541462998
Email ID -
[email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.cables.energya.com

2. 8 Page 70 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Bahra Advance Cable Manufacture Co. Up to 630 mm2 KEMA – Netherlands PQ Letter
Ltd Up to 13.8kV during April 15, 2016
Saudi Arabia to May 31, 2016. Based on S&SD Letter # 16-07712-1-30504401
Report No.: 1261-16 dated October 04, 2016, Bahra Advanced Cable
Po Box 5989 Jeddah 21432 , Saudi & 1257-16 for single Manufacture Co. Ltd – Jeddah KSA is
Arabia core & Multi Core pre-qualified for MV Cables as conforming to
Medium Voltage National Grid SA Specification # 11-TMSS-04 with
Contact Person - Mr. Loai Taha Al-Bar, Cables. the following conditions:
Sale Manager
Phone - +966-2-591-1115 • Ten (10) years extended warranty from the
Email ID - [email protected] date of PAC of the first turnkey project (in case
of contract award) or date of first delivery (in
case of direct material supply order), as
confirmed through Bahra Advanced Cable
Manufacture Co. Ltd – Jeddah KSA letter # nil
dated September 06, 2016.

• Previously Bahra Cable Co.

Total = 12

CONDUCTOR, INSULATED
2. 9
MEDIUM VOLTAGE POWER CABLE - XLPE , 33 & 34.5 kV Applicable Standards: 11-TMSS-04

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Tests performed at: Including Joints & Terminations
KOREA, Republic of Co., Ltd. Branch KEMA,
P. O. Box 300201, Netherlands
Plant -Dangjin Factory Riyadh 11372, Office No. (Dec. 1986)
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected]
Phone - +82 2 316 9190
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.taihan.com

2. 9 Page 71 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY CABLES Up to 630 mm², 34.5 KV • 34.5kV 1x630mm2: PQ Letter:


Saudi Arabia Tests performed at
KEMA, Netherlands Based on S&SD letter # 17-07027-2-30504401
Plant -Yanbu, Saudi Arabia (August,2017) dated October 17, 2017, Elsewedy Cables,
Report # 1114-17 Yanbu - KSA is pre-qualified for MV Cables as
P.O Box 31670 Yanbu Al Sinaiyah • 34.5kV 1x630mm2: conforming to National Grid SA specification #
41912, Saudi Arabia Tests performed at 11-TMSS-04, with the following conditions:
KEMA, Netherlands
Contact Person - Hassan A. Hassan, (August,2017) WARRANTY:
Maher Mohamed Report # 1130-17
Phone - Tel : +966 14 3570166, Mobile: • 34.5kV 3x500mm2: Ten (10) years extended warranty/guarantee in
+966 540069254, Fax : +966 (Al) Tests performed respect of defects due to design, manufacture,
143572223 at KEMA, installation and workmanship from the date of
Email ID - [email protected] Netherlands Provisional Acceptance Certificate (PAC) of the
[email protected] (August,2017) first turnkey project in case of contract award
Contact Person Email ID - Report # 1122-17 or date of first delivery in case of direct material
[email protected] • 34.5kV 3x500mm2: supply order, as confirmed by the manufacturer
[email protected] (Al) Tests performed vide letter # Nil, dated January 11, 2016.
Website - at KEMA,
http://www.elsewedyelectric.com/FE/C Netherlands
ommon/Companies.aspx?ID=27&g=3 (August,2017)
Report # 1129-17

Gaon Cables CO., LTD. Abdulaziz M. AlSuwaiket MV Power Cable up to 1000 mm² Type Tests PQ letter:
SOUTH KOREA (AlSuwaiket) conducted in KEMA Based on S&SD letter # 18-01986-030504401
(AlSuwaiket) during 01 to 09 dated May 24, 2018 for Gaon Cables. Gunpo,
Plant -Gunpo +966-13-857-1155 March 2018 Korea is pre-qualified for Medium Voltage Power
[email protected] Report no 01 14440 Cables as conforming to latest National Grid SA
120, LS-ro 45beon-gil, Gunpo-si, om A (by SGS) specification # 11-TMSS-04, with the following
Gyeonggi-do, 15841, Republic of Korea conditions:

Contact Person - 1.SeongJun Kim WARRANTY:


(GAON CABLE CO., LTD.) Ten (10) years extended warranty/guarantee in
Phone - +82-2-6921-3880 respect of defects due to design, manufacture,
Email ID - [email protected] installation and workmanship from the date of
Contact Person Email ID - Provisional Acceptance Certificate (PAC) of the
[email protected] first turnkey project in case of contract award or
Website - www.gaoncable.com date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated April 12, 2016.

2. 9 Page 72 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL 1x 630 mm2, 36kV Tests performed at: PQ Letter


Saudi Arabia Kinectrics Based on S&SD Letter 13-05014-2-30504401
Canada (Mar. 2013 dated September 08, 2013, it is pre-qualified for
Plant -Saudi Arabia to April, Insulated Conductor Cable (XLPE) with the
2013) following conditions:
Po Box 301 , Riyadh 11411 ,North Righ Report:
Road Between Exit 5 & 6 K-422869-RC-0001- WARRANTY:
R01 Ten (10) years extended warranty/guarantee in
Riyadh respect of defects due to design, manufacture,
installation & workmanship from the date of
Contact Person - Sultan Alghamdi " VIP Provisional Acceptance Certificate (PAC) of the
key Account Manegr "; Saleh first turnkey project in case of contract award or
Almehaijeen "Projects Sales Engineer " date of first delivery in case of direct material
Phone - 920006111 supply order, as confirmed by the manufacturer
Contact Person Email ID - vide letter#Nil, dt: Mar 10, 2013.
[email protected];
[email protected] Note:
Website - www.alfanar.com MV Power Cable beyond cable size of 630 mm2
to be supplied to National Grid SA shall be fully
type tested at an accredited laboratory in the
presence of National Grid SA Engineers & third
party inspector.

2. 9 Page 73 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SAUDI CABLE
Saudi Arabia

Plant -Jeddah, Saudi Arabia

Saudi Cable Company


P.O. BOX 4403 Jeddah 21491
Industrial Area-Jeddah, Saudi Arabia

Fax Number: +966 12 637 9877

Jeddah

Contact Person - Ammar R. Qari


Phone - +966 12 608 7666
Email ID - [email protected] ,
[email protected]
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

RIYADH CABLES Up to 1x1000 mm², 33 KV 1. Tests performed


Saudi Arabia at: KSU,
Riyadh, K.S.A (Jan.
Plant -Riyadh 2012)
Report #
P.O. Box 26862- Riyadh, 11496 Riyadh TRC-0011433
, Saudi Arabia
2nd Industrial City, Al Kharj Road, street 2. Tests performed
No. 175, 3rd Lane Zone D. Riyadh, at: Riyadh Cable's
Kingdom of Saudi Arabia RCB Laboratory,
Riyadh, K.S.A (30
Contact Person - Mr. Dr. Abdulmohsen April -20 May, 2017)
Aliheraish – Vice Executive Director; Report #
Mr. Mohammad Al-Shmoury, T/RCC/0441-17
Phone - +966 11 2650850 Ext:238 ;
+966 11 2651415
Email ID - [email protected];
[email protected];
[email protected]
Website -
http://www.riyadh-cables.com/

2. 9 Page 74 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS PREVIOUSLY LG; Including Joints & Terminations


SOUTH KOREA

Website - http://www.lscable.com/

DUBAI CABLE CO. Including Joints & Terminations


United Arab Emirates

P.O.Box 683, Dubai - U.A.E

Contact Person - Mr. Ahmed Abou


Elenien
Phone - (+9714) 815 8600
Email ID - [email protected]
Contact Person Email ID -
[email protected],
[email protected],
[email protected]
Website - www.ducab.com

ELSEWEDY EGYTECH CABLE CO.


EGYPT

Egytec Cables- El Sewedy, 3Rd


Industrial Zone A3, 10Th Of Ramadan
City Egypt P.O. Box: 1748 - Post Code:
10505- , Egypt

Contact Person - Mr. Eng Eslam Aly


Phone - +20227599732
Email ID - [email protected]
Website - http://
http://www.elsewedycables.com/

OMAN CABLE INDUSTRIES Ref# is 08-02531/01-0303230 dated 08/ 11/2008


Oman No Accessories are pre-qualified

muscat

Website -
http://www.omancables.com/

2. 9 Page 75 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SHOWA CABLE Including Joints & Terminations


JAPAN

Website - http://
http://www.swcc.co.jp/eng/index.htm

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan Including Joints & Terminations

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

DAINICHI-NIPPON CABLES Including Joints & Terminations


(MITSUBISHI)
JAPAN

DEMIRER KABLO
TURKEY

Demirer Kablo, Tesisleri San. Ve Tic


A.S. 4 Eylul Mahallesi Ismet Inonu
Caddesi No. 279 Bozuyuk/ Bilecik-
Turkey

Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=

FUJIKURA CABLES Including Joints & Terminations


JAPAN

Website - http://www.ffcpg.com.my

2. 9 Page 76 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MKM Including Joints & Terminations


HUNGARY

Email ID - lang=en
Website -
http://www.mkm-?mediline.de/index.ph
p/edv-und-software-?entwicklung/mkm
-computer-network-?ungarn?lang=en?

JEDDAH CABLE CO.


Saudi Arabia

Plant -jeddah

Po Box 31248 , Jeddah 21497 Jeddah ,


Saudi Arabia

jeddah

Contact Person - Mr. Alaa Dandachi ,


Mohammad Said Minkara
Phone - +966-126360770, 0541462998
Email ID -
[email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.cables.energya.com

2. 9 Page 77 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Bahra Advance Cable Manufacture Co. Up to 630 mm2 KEMA – Netherlands PQ Letter
Ltd Up to 33kV during April 15, 2016
Saudi Arabia to May 31, 2016. Based on S&SD Letter # 16-07712-1-30504401
Report No.: 1261-16 dated October 04, 2016, Bahra Advanced Cable
Po Box 5989 Jeddah 21432 , Saudi & 1257-16 for Single Manufacture Co. Ltd – Jeddah KSA is
Arabia Core & Multi Core pre-qualified for MV Cables as conforming to
Medium Voltage National Grid SA Specification #11-TMSS-04 with
Contact Person - Mr. Loai Taha Al-Bar, Cables. the following conditions:
Sale Manager
Phone - +966-2-591-1115 • Ten (10) years extended warranty from the
Email ID - [email protected] date of PAC of the first turnkey project (in case
of contract award) or date of first delivery (in
case of direct material supply order), as
confirmed through Bahra Advanced Cable
Manufacture Co. Ltd – Jeddah KSA letter # nil
dated September 06, 2016

• Previously Bahra Cable Co.

Total = 18

CONDUCTOR, INSULATED
2. 10
Distributed Temperature Sensing (DTS) System for U/G Power Cable Applicable Standards: 11-TMSS-06

2. 10 Page 78 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Yokogawa Electric Corporation Yokogawa Saudi Arabia DTSX200 and DTSX3000 Yokogawa Electric PQ Letter
JAPAN Company, Saudi Corporation, Japan Based on S&SD letter # 17-02871-5-30504401
Arabia-Dhahran has successfully dated April 19,2017 , Yokogawa Electric
Plant -Japan Ibn Rushd Street, completed type tests Corporation, Japan is pre-qualified for Distributed
Dhahran Techno-Valley - on Distributed Temperature Sensing System (Type: DTSX200
Yokogawa Manufacturing Corporation Dhahran, P.O.Box 3368, Temperature and DTSX3000) as conforming to National Grid
Koufu Factory 155, Takamurocho, Al-Khobar 31952, Sensors (DTS) Type SA specification # 11-TMSS-06, with the
Kofu-City, Yamanashin 400-8558- Kingdom of Saudi Arabia DTSX200 and following conditions:
Japan +966 (13) 331 9600 DTSX3000 in
[email protected] presence of three WARRANTY:
Kofu ogawa.com SEC/National Grid Ten (10) years extended warranty in respect of
SA Engineers and defects due to design, manufacturing and
Contact Person - Mr. Teichi Matsumoto third party inspector workmanship from the date of PAC of the first
& Mr. Hazem A. Hassan at Independent turnkey project (in case of contract award) or
Phone - +81-55-243-0480 testing laboratory UL from the date of first delivery (in case of direct
Email ID - – Japan on 30 May material supply order), as confirmed, through
[email protected] 2016 & Yokogawa their Letter No. SSD-PDZZ21-G15-25-3 dated
Contact Person Email ID - Electric Corporation 20/01/2016.
[email protected] Laboratory- Japan
Website - WWW.yokogawa.co.jp during 26 to 27 May
2016.

AP SENSING GmbH Adwan Marketing N43, N44 & N45 Series DTS units Type test performed PO Letter
GERMANY Company in Keysight Based on S&SD Letter No. 16-01996-1-30504401
PO Box: 64273, Riyadh technologies dated 21 March 2016, AP Sensing Gmbh
Plant -Boblingen Germany 11536, Kingdom of Saudi Deutschland GmbH Boblingen, Germany is Pre-qualified for
Arabia Germany hardware Distributed Temperature sensing (DTS) with the
Herrenbergerstr 130 71034 B +966 11495 5332 ext 112 test center following condition.
Boblingen Germany sohail@adwanmarketing Herrenberger Strabe
.com 130 70034 Extended Warranty:
Contact Person - Mr. Mujaheed Ahmed Boblingen . Test Ten (10) Years extended warranty as confirmed
Phone - Tel: +49 7031 309 6610 Fax: report No. through AP SENSING Letter No. Nil dated 28 Feb
+49 7031 309 6611 GHTC-2015-005-TI 2014 shall be applicable for all supplies made to
Email ID - dated 05-02-2015 the company by the Manufacturer.
[email protected], accredited by
[email protected] DAKKS Deutsche
Contact Person Email ID - Akkreditierungsstelle
[email protected] D-PL-19882-01.
Website - www.apsensing.com

Total = 2

2. 10 Page 79 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CONDUCTOR, INSULATED
2. 11
DTS System Integration, Assembly and Factory Acceptance Testing (FAT) Applicable Standards:

Yokogawa Saudi Arabia Company PQ Letter


Saudi Arabia Based on S&SD letter # 17-02871-4-30504401
dated April 19,2017 , Yokogawa Electric Saudi
Plant -Saudi Arabia-Dhahran Arabia-Dhahran is pre-qualified for Integration,
Assembly and Factory Acceptance Testing (FAT)
Dhahran of Distributed Temperature Sensing System from
Original Equipment Manufacturer (OEM) type
Contact Person - Mr. Teichi Matsumoto tested & approved by SEC/National Grid SA as
& Mr. Hazem A. Hassan conforming to National Grid SA specification #
Phone - +966 (13) 331 9600 11-TMSS-06, with the following conditions:
Contact Person Email ID -
[email protected] CONDITION
Website - WWW.yokogawa.co.jp Only for Integration, Assembly & Factory
Acceptance Testing of DTS System from original
equipment manufacturer (OEM) type tested and
approved by SEC/National Grid SA.

WARRANTY
Ten (10) years extended warranty in respect of
defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), as confirmed, through
their Letter No. NIL dated 13/10/2016.

Total = 1

CONDUCTOR, INSULATED
2. 12
POWER AND/OR CONTROL CABLES COPPER OR ALUMINUM CONDUCTOR 600/1000V Applicable Standards: 11-TMSS-10
RATING

2. 12 Page 80 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

United Cable Industries Company Low Voltage Cables (1X630mm2 0.6/1 kV PQ Letter
(UCIC) Cu/XLPE/AWA/PVC & 48x2.5 mm2 Based on S&SD letter #MPQ1359162-Class I(b)
Jordan Cu/PVC/SWA/PVC). -1x630mm2: Type -2017 dated July 29, 2021, the manufacturer is
Tests successfully prequalified for LV power & Control Cables as
Plant -Jordan completed at DEKRA confirming to National Grid SA specification
- Report# - #11-TMSS-10, with the following conditions:
Zarka-Mafraq Highway Thaghret Aljob 2253356.51-CAT
Jaber Highway Mafraq dated 11-May-2021 WARRANTY
Ten (10) years extended warranty from the date
Contact Person - Mr. E.Marwan -48x2.5mm2: Type of PAC of the first turnkey project (in case of
Karawan , QA/QC Section Head Tests successfully contract award) or date of first delivery (in case
Phone - 00962-6-5549292 completed at DEKRA of direct material supply order), as confirmed,
Email ID - [email protected] - Report# - through their Letter #Nil dated January 23, 2018,
Website - http://www.uciccables.com 2253356.52-CAT shall be applicable for the equipment to be
dated 11-May-2021 supplied to SEC/National Grid SA.

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Tests performed
KOREA, Republic of Co., Ltd. Branch (March 2008)
P. O. Box 300201,
Plant -Dangjin Factory Riyadh 11372, Office No.
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected]
Phone - +82 2 316 9190
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.taihan.com

2. 12 Page 81 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY CABLES Up to 630 mm², 1 KV • 0.6/1kV PQ Letter:


Saudi Arabia 1x630mm2: Tests Based on S&SD letter # 17-07027-2-30504401
performed at KEMA, dated October 17, 2017, Elsewedy Cables,
Plant -Yanbu, Saudi Arabia Netherlands Yanbu - KSA is pre-qualified for LV Power &
(September,2017) Control Cables as conforming to National Grid SA
P.O Box 31670 Yanbu Al Sinaiyah Report # 1102-17 specification # 11- TMSS-10, with the following
41912, Saudi Arabia • 0.6/1kV conditions:
12x2.5mm2: Tests
Contact Person - Hassan A. Hassan, performed at KEMA, WARRANTY:
Maher Mohamed Netherlands Ten (10) years extended warranty/guarantee in
Phone - Tel : +966 14 3570166, Mobile: (September,2017) respect of defects due to design, manufacture,
+966 540069254, Fax : +966 Report # 1109-17 installation and workmanship from the date of
143572223 Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] first turnkey project in case of contract award or
[email protected] date of first delivery in case of direct material
Contact Person Email ID - supply order, as confirmed by the manufacturer
[email protected] vide letter # Nil, dated January 11, 2016.
[email protected]
Website -
http://www.elsewedyelectric.com/FE/C
ommon/Companies.aspx?ID=27&g=3

Gaon Cables CO., LTD. Abdulaziz M. AlSuwaiket LV Power and/or Control Cable up to Type Tests PQ letter:
SOUTH KOREA (AlSuwaiket) 630 mm² conducted in KEMA Based on S&SD letter # 18-01986-030504401
(AlSuwaiket) during 01 to 09 dated May 24, 2018 for Gaon Cables. Gunpo,
Plant -Gunpo +966-13-857-1155 March 2018 Korea is pre-qualified for Low Voltage Power &
[email protected] Report no 01 14440 Control Cables as conforming to latest National
120, LS-ro 45beon-gil, Gunpo-si, om B (by SGS) Grid SA specification # 11-TMSS-10, with the
Gyeonggi-do, 15841, Republic of Korea Report no 01 14440 following conditions:
C (by SGS)
Contact Person - 1.SeongJun Kim WARRANTY:
(GAON CABLE CO., LTD.) Ten (10) years extended warranty/guarantee in
Phone - +82-2-6921-3880 respect of defects due to design, manufacture,
Email ID - [email protected] installation and workmanship from the date of
Contact Person Email ID - Provisional Acceptance Certificate (PAC) of the
[email protected] first turnkey project in case of contract award or
Website - www.gaoncable.com date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated April 12, 2016.

2. 12 Page 82 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL XLPE Cable Tests performed at: PQ Letter


Saudi Arabia Rating - 0.4kV/1kV , KEMA, Netherlands Based on TS&SD letter# 09-01432-03032301
0.6 k/1.0 kV & 3.6 kV (Nov, 2011) dated 16th. May 2009 is pre-qualified for Low
Plant -Saudi Arabia Report # TIC 1485 to Voltage Power & Control Cables 0.6/1kV with the
91 (Coaxial cable) following conditions:
Po Box 301 , Riyadh 11411 ,North Righ
Road Between Exit 5 & 6 WARRANTY:
Ten (10) years extended warranty/guarantee in
Riyadh respect of defects due to design, manufacture,
installation & workmanship from the date of PAC
Contact Person - Sultan Alghamdi " VIP of the turnkey project in case of contract award
key Account Manegr "; Saleh or date of delivery in case of direct material
Almehaijeen "Projects Sales Engineer " supply order.
Phone - 920006111
Contact Person Email ID -
[email protected];
[email protected]
Website - www.alfanar.com

BELDEN
United States

Website - http://www.belden.com/

MIDDLE EAST SPECIALIZED CABLE CO. Previously JORDAN NEW CABLE COMPANY-
MESC, JORDAN-
JORDAN AMMAN [The name has been changed based on
S&SD/P&SFD letter # 14-01869-30504401 dated
Jordan March 24, 2014].

2. 12 Page 83 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TEKAB CO. LTD. LV Power & Control Cables upto 630 TEKAB Certificate # PQ letter:
United Arab Emirates mm² Size with Copper Conductor ( TCL/TTC-1810300 Based on S&SD letter# 13-07588-30504401
except clause 4.3.5c for corrugated dated 16.10.2018 dated December 11, 2013 & S&SD letter#
Sharjah , United Arab Emirates armors) for LV Power Cable 18-4055-01-30504401 dated November 04, 2018,
KEMA TEST REPORT it is pre-qualified for Power and/or Control Cable
Website - http://www.tekab.com/ # 1633-17 dated Copper 600/1000 Volts for All LV power & control
22.01.2018 for LV cables upto 630 mm² size
Power Cable
KEMA TEST REPORT WARRANTY:
# 3188-17 dated Ten (10) years extended warranty/guarantee in
25.06.2018 for LV respect of defects due to design, manufacture,
Control Cable installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #0580/SO/13, dt: Nov 17, 2013

SAUDI CABLE
Saudi Arabia

Plant -Jeddah, Saudi Arabia

Saudi Cable Company


P.O. BOX 4403 Jeddah 21491
Industrial Area-Jeddah, Saudi Arabia

Fax Number: +966 12 637 9877

Jeddah

Contact Person - Ammar R. Qari


Phone - +966 12 608 7666
Email ID - [email protected] ,
[email protected]
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

2. 12 Page 84 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RIYADH CABLES Tests performed at:


Saudi Arabia KEMA,
Netherlands (Nov.
Plant -Riyadh 2011)
Report # TIC
P.O. Box 26862- Riyadh, 11496 Riyadh 1501-11 &
, Saudi Arabia TIC 1502-11
2nd Industrial City, Al Kharj Road, street
No. 175, 3rd Lane Zone D. Riyadh,
Kingdom of Saudi Arabia

Contact Person - Mr. Dr. Abdulmohsen


Aliheraish – Vice Executive Director;
Mr. Mohammad Al-Shmoury,
Phone - +966 11 2650850 Ext:238 ;
+966 11 2651415
Email ID - [email protected];
[email protected];
[email protected]
Website -
http://www.riyadh-cables.com/

MIDDLE EAST SPECIALIZED CABLE


(MESC)
Saudi Arabia

Riyadh , Saudi Arabia

Website -
http://www.mesccables.com/

2. 12 Page 85 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY EGYTECH CABLE CO. PQ Letter


EGYPT Based on TS&SD fax ref#
09-00303/01-03032301 dated 18/02/2009.
Egytec Cables- El Sewedy, 3Rd
Industrial Zone A3, 10Th Of Ramadan
City Egypt P.O. Box: 1748 - Post Code:
10505- , Egypt

Contact Person - Mr. Eng Eslam Aly


Phone - +20227599732
Email ID - [email protected]
Website - http://
http://www.elsewedycables.com/

OMAN CABLE INDUSTRIES PQ Letter


Oman Based on TS&SD letters # 10-02435-03032301,
dated 06/09/2010 & 10-02611-03032301 dated
muscat 02/10/2010, it is pre-qualified for LV Power&
Control Cables (0.6/1kV) with the following
Website - condition:
http://www.omancables.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 21/08/2010.

2. 12 Page 86 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JEDDAH CABLE CO.


Saudi Arabia

Plant -jeddah

Po Box 31248 , Jeddah 21497 Jeddah ,


Saudi Arabia

jeddah

Contact Person - Mr. Alaa Dandachi ,


Mohammad Said Minkara
Phone - +966-126360770, 0541462998
Email ID -
[email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.cables.energya.com

Bahra Advance Cable Manufacture Co. Low Voltage Cables (1X630mm2 & KEMA –Netherland PQ Letter
Ltd 4x300 mm2 CU/XLPE/PVC-FR 1KV) & during 18th to 25th Based on S&SD letter # 15-01562-1-30504401
Saudi Arabia April 2014 & dated March 18 2015 nd S&SD letter #
KINECTRICS-Canada 16-00558-1-30504401 dated February 15 2016,
Po Box 5989 Jeddah 21432 , Saudi during 18th to 24th the manufacturer is prequalified for LV power
Arabia Aug 2014 Report cables with the following condition:
No.TIC 1018-14 for
Contact Person - Mr. Loai Taha Al-Bar, multi-core power WARRANTY:
Sale Manager cable, TIC 1019-14 Ten (10) years extended warranty/guarantee in
Phone - +966-2-591-1115 for single-core respect of defects due to design, manufacture,
Email ID - [email protected] power cable installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order as confirmed by the manufacturer
through their letter # (BCC/AQ/GSM/MZ dated
August 20,2011) for LV cables and letter # ( 1005
/ BH / 2016 dated 14/02/2016) for control cable.

Previously Bahra Cable Co.

Total = 15

2. 12 Page 87 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CONDUCTOR, INSULATED
2. 13
SHIELDED INSTRUMENTATION CABLE Applicable Standards: 11-TMSS-11

SAUDI CABLE PQ Letter


Saudi Arabia Based on TS&SD fax ref.#08-02969-3-03032301
dated 07/01/2009. Pre-Qualified for Shielded
Plant -Jeddah, Saudi Arabia Instrumentation & Thermocouple Cables with this
conditions:
Saudi Cable Company
P.O. BOX 4403 Jeddah 21491 CONDITION:
Industrial Area-Jeddah, Saudi Arabia All type, design, special & routine tests as per
SEC specifications/standards shall be carried out
Fax Number: +966 12 637 9877 on the first batch to be supplied to SEC in the
presence of three (3) SEC engineers & one (1)
Jeddah approved independent inspection agency
Inspector.
Contact Person - Ammar R. Qari
Phone - +966 12 608 7666 WARRANTY:
Email ID - [email protected] , Ten (10) years extended warranty/guarantee in
[email protected] respect of defects due to design, manufacture,
Contact Person Email ID - installation & workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
Website - www.saudicable.com first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.nil, dt: 20th july, 2008.

BELDEN
United States

Website - http://www.belden.com/

2. 13 Page 88 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TEKAB CO. LTD. Instrumentation Cables without Metallic KEMA TEST REPORT PQ letter:
United Arab Emirates Sheath # 3187-17 dated Based on S&SD letter# 18-4055-01-30504401
25.06.2018 for LV dated November 04, 2018, it is pre-qualified for
Sharjah , United Arab Emirates Instrumentation instrumentation Cables without Metallic Sheath
Cables
Website - http://www.tekab.com/ WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

ALPHA
United States

Website - http://www.alpha.com/

AT & T
United States

New York , United States

Website - http://www.att.com/

MIDDLE EAST SPECIALIZED CABLE


(MESC)
Saudi Arabia

Riyadh , Saudi Arabia

Website -
http://www.mesccables.com/

Total = 6

CONDUCTOR, INSULATED
2. 14
EARTHING AND BONDING CABLE Applicable Standards: 11-TMSS-12

2. 14 Page 89 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSEWEDY CABLES i. Coaxial Bonding Cable 600/1000V & Type test report # PQ Letter
Saudi Arabia 1800/3000V up to 500mm2 ii. Single 1102-17 conducted Based on S&SD letter # 22-01157-30504401
Core Bonding Cable 600/1000V & in KEMA-Netherland. dated September 18, 2022, the manufacturer is
Plant -Yanbu, Saudi Arabia 1800/3000V up to 500 mm2 iii. Earthing prequalified for EARTHING AND BONDING CABLE
Cable 600/1000V & 1800/3000V up to as confirming to National Grid SA specification
P.O Box 31670 Yanbu Al Sinaiyah 500 mm2 #11-TMSS-12, with the following conditions:
41912, Saudi Arabia

Contact Person - Hassan A. Hassan, WARRANTY:


Maher Mohamed Ten (10) years extended warranty from the date
Phone - Tel : +966 14 3570166, Mobile: of PAC of the first turnkey project (in case of
+966 540069254, Fax : +966 contract award) or date of first delivery (in case
143572223 of direct material supply order), as confirmed,
Email ID - [email protected] through their Letter #Nil dated September 1, 2022,
[email protected] shall be applicable for the equipment to be
Contact Person Email ID - supplied to SEC/National Grid SA.
[email protected]
[email protected]
Website -
http://www.elsewedyelectric.com/FE/C
ommon/Companies.aspx?ID=27&g=3

ALFANAR ELECTRICAL Bonding Cable Tests performed at: PQ Letter


Saudi Arabia KEMA, Netherlands Based on TS&SD letter# 09-01432-03032301
(Nov, 2011) dated 16th. May 2009 is pre-qualified for bonding
Plant -Saudi Arabia Report # TIC 1502- cables:

Po Box 301 , Riyadh 11411 ,North Righ WARRANTY:


Road Between Exit 5 & 6 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Riyadh installation & workmanship from the date of PAC
of the turnkey project in case of contract award
Contact Person - Sultan Alghamdi " VIP or date of delivery in case of direct material
key Account Manegr "; Saleh supply order.
Almehaijeen "Projects Sales Engineer "
Phone - 920006111
Contact Person Email ID -
[email protected];
[email protected]
Website - www.alfanar.com

2. 14 Page 90 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FUJIKURA VISCAS CORP


JAPAN

Website - http://www.ffcpg.com.my/

PIRELLI
GERMANY

Berlin , Germany

Website - http://
http://www.pirelli.com/splash/index.htm
l

SAUDI CABLE
Saudi Arabia

Plant -Jeddah, Saudi Arabia

Saudi Cable Company


P.O. BOX 4403 Jeddah 21491
Industrial Area-Jeddah, Saudi Arabia

Fax Number: +966 12 637 9877

Jeddah

Contact Person - Ammar R. Qari


Phone - +966 12 608 7666
Email ID - [email protected] ,
[email protected]
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

2. 14 Page 91 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RIYADH CABLES
Saudi Arabia

Plant -Riyadh

P.O. Box 26862- Riyadh, 11496 Riyadh


, Saudi Arabia
2nd Industrial City, Al Kharj Road, street
No. 175, 3rd Lane Zone D. Riyadh,
Kingdom of Saudi Arabia

Contact Person - Mr. Dr. Abdulmohsen


Aliheraish – Vice Executive Director;
Mr. Mohammad Al-Shmoury,
Phone - +966 11 2650850 Ext:238 ;
+966 11 2651415
Email ID - [email protected];
[email protected];
[email protected]
Website -
http://www.riyadh-cables.com/

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

2. 14 Page 92 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES PREVIOUSLY LG
SOUTH KOREA

Plant -Gumi/Korea

13 F Ls Tower ,127, Ls-Ro,


Dongan-Gu, Anyang-Si, Gyeonggi-Do,
Korea

Contact Person - Jiyup Baik


Phone - +82-544697602
Email ID - [email protected]
Website - http://www.lscns.com

JEDDAH CABLE CO. PQ Letter


Saudi Arabia Based on S&SD letter # 15-04684-02-30504401
dated June 18, 2015, the manufacturer is
Plant -jeddah prequalified to supply coaxial bonding/ earthing
cable, as conforming to National Grid SA
Po Box 31248 , Jeddah 21497 Jeddah , specification # 11-TMSS-12.
Saudi Arabia
WARRANTY:
jeddah Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
Contact Person - Mr. Alaa Dandachi , installation and workmanship from the date of the
Mohammad Said Minkara Provisional Acceptance Certificate (PAC) of the
Phone - +966-126360770, 0541462998 project (in case of contract award) and from the
Email ID - date of delivery in case of direct material supply
[email protected] order shall be provided as confirmed by the
Contact Person Email ID - manufacturer through their extended warranty
[email protected] letter attached with the letter #
Website - JCC-EP-PQ-0105-14-05 dated May 24, 2015.
http://www.cables.energya.com

2. 14 Page 93 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Bahra Advance Cable Manufacture Co. i. Coaxial Bonding Cable 600/1000V Type test report #TIC PQ Letter
Ltd & 1800/3000V up to 500mm2 1019-14 conducted Based on S&SD letter # 17-00912-1-30504401
Saudi Arabia ii. Single Core Bonding Cable in KEMA-Netherland. dated February 16, 2017, BAHRA ADVANCE
600/1000V & 1800/3000V up to 500 CABLE MANUFACTURE Co. Ltd –JEDDAH, KSA is
Po Box 5989 Jeddah 21432 , Saudi mm2 pre-qualified for the proposed Coaxial Bonding
Arabia iii. Earthing Cable 600/1000V & and Earthing Cable as conforming to National
1800/3000V up to 500 mm2 Grid SA specification # 11-TMSS-12 rev.0, with
Contact Person - Mr. Loai Taha Al-Bar, the following conditions:
Sale Manager
Phone - +966-2-591-1115 WARRANTY:
Email ID - [email protected] Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their letter # Nil, dated October 25, 2016
shall be applicable for all proposing Coaxial,
Bonding Earthing Cable to be supplied to
SEC/National Grid SA.

Total = 10

CONDUCTOR, INSULATED
2. 15
Submarine Power Cables, XLPE Insulated 69kV up to 500kV Rating Applicable Standards: 11-TMSS-05

2. 15 Page 94 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hengtong Submarine Power cable Co., • 132 kV XLPE Submarine Power


Ltd & Hengtong Marine Cable System Cables Land Cable is considered to be approved for
Co., Ltd • Submarine Fiber Optic Cables Submarine Cable Projects only.
CHINA •132kV Cu/XLPE/CWS/LEAD/HDPE
Land Cables PQ Letter
Plant -China
Based on S&SD letter #23-001348/01-30504401
Hengtong Submarine Power cable Co., dated August 13, 2023, the manufacturer is
Ltd & Hengtong Marine Cable System prequalified for 132 kV XLPE Submarine Power
Co., Ltd Cables, Submarine Fiber Optic Cables and
132kVCu/XLPE/CWS/LEAD/HDPE Land Cables as
Suzhou confirming to National Grid SA specification #
11-TMSS-05, with the following conditions:
Contact Person - Eric Fan; Jimmy
Sheng; Emma Hu TYPE TEST:
Phone - +86 51263957850
Email ID - [email protected] M/s Hengtong China has submitted type test
Contact Person Email ID - confirmation to conduct complete type test in the
[email protected]; presence of SEC/National Grid SA engineers &
[email protected]; third party inspector during first project awarded
[email protected] through their Letter Ref. below
Website - +86 51263957850
• For 132 kV XLPE Submarine Power Cables
Letter ref# 4000074183 dated 28.04.2023
• For Submarine Fiber Optic Cables Letter ref#
20230413 dated 06.05.2023
• 132kVCu/XLPE/CWS/LEAD/HDPE Land Cables
Letter ref# 4000074183 dated 17.05.2023

WARRANTY
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered 132 kV
XLPE Submarine Power Cables, Submarine Fiber
Optic Cables and
132kVCu/XLPE/CWS/LEAD/HDPE Land Cables in
respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as

2. 15 Page 95 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

confirmed by the manufacturer, through their


Letter Ref. below:

• For 132 kV XLPE Submarine Power Cables


Letter ref# 4000074183 dated 28.04.2023
• For Submarine Fiber Optic Cables Letter ref#
20230413 dated 06.05.2023
• 132kVCu/XLPE/CWS/LEAD/HDPE Land Cables
Letter ref# 4000074183 dated 17.05.2023

2. 15 Page 96 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Zhongtian Technology Submarine Cable • For 132 kV XLPE Submarine Power PQ Letter
Co., Ltd (ZTT) Cables
CHINA • For Submarine Fiber Optic Cables Based on S&SD letter #23-001364/01-30504401
dated August 13, 2023, the manufacturer is
Plant -China prequalified for 132 kV XLPE Submarine Power
Cables and Submarine Fiber Optic Cables as
No.1, Xinkai South Road, Nantong confirming to National Grid SA specification #
ETDZ, Jiangsu Province, China. 11-TMSS-05, with the following conditions:

Nantong TYPE TEST:


M/s ZTT China has submitted type test
Contact Person - Lary Gu confirmation to conduct complete type test in the
Phone - +86 513 83599774 presence of SEC/National Grid SA engineers
Email ID - [email protected] &third party inspector during first project
Contact Person Email ID - awarded through their Letter Ref. below.
[email protected]
Website - www.zttcable.com • For 132 kV XLPE Submarine Power Cables
Letter ref# ZTTPQLS00032501 dated 25.03.2023
• For Submarine Fiber Optic Cables Letter ref#
ZTTPQLS00032509 dated 25.03.2023

WARRANTY
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered 132 kV
XLPE Submarine Power Cables, Submarine Fiber
Optic Cables in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. below.

• For 132 kV XLPE Submarine Power Cables


Letter ref# ZTTPQLS00032201 dated 22.03.2023
• For Submarine Fiber Optic Cables Letter ref#
ZTTPQLS00071201 dated 12.07.2023

2. 15 Page 97 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sumitomo Electric industries, Ltd • For 132 kV XLPE Submarine Power PQ Letter
JAPAN Cables
Based on S&SD letter #23-001471/01-30504401
Plant -Minato dated August 13, 2023, the manufacturer is
prequalified 132 kV XLPE Submarine Power
Akasaka Center Building, 1-3-13, Cables as confirming to National Grid SA
Motoakasaka, Minato-ku, Tokyo specification # 11-TMSS-05, with the following
107-8468 conditions:

Contact Person - Amjad Abdelaziz TYPE TEST:


Phone - +81364062790 M/s Sumitomo Electric industries Japan has
Email ID - [email protected] submitted type test confirmation to conduct
Website - https://sumitomoelectric.com complete type test in the presence of
SEC/National Grid SA engineers &third party
inspector during first project awarded through
their Letter Ref. below

• For 132 kV XLPE Submarine Power Cables


Letter ref# KDE-RF22-123 dated 10th July. 2023

WARRANTY
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered 132 kV
XLPE Submarine Power Cables in respect of the
defects due to design, manufacturing, installation
and workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. below

• For 132 kV XLPE Submarine Power Cables


Letter ref# KDE-RF22-129 dated 10th July. 2023

Total = 3

CONDUCTOR FITTINGS
3. 1
LINE HARDWARE Applicable Standards: 12-TMSS-01

3. 1 Page 98 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALCOA
United States

Website -
http://www.alcoa.com/usa/en/home.as
p

JOSLYN
United States

Website -
http://www.joslynhivoltage.com/

A SALVI & C S.r.l Line Hardware up to380 kV - Tests performed Previous location was "Italy", the location has
FRANCE - Spacer Damper type (Twin) with at: SVEPPI, been change to "France" based on letter #
drawing #3931B456D9277 Rev.0 DEMONT, VEIKI 20-00200-030504401 dated 21.1.2020.
Le Chambon plant, France - Spacer Damper type (Quad) with (2013) Report # RP
drawing # 3931QS456D927 Rev.0 LS 13/131, RP LS
Contact Person - Mr. Giovanni Sangalli 13/202E, 7307/VNL,
(Technical Manager) 7117/VNL, RP LS
Phone - +3902.376715.1, Fax +39 13/127C&D, RP LS
02.376715.222 13/202 A&D, 14/035,
Email ID - [email protected] 14/059, 14/037 &
Contact Person Email ID - 14/052-1
[email protected] - Type tests were
Website - http://www.salvi.eu conducted on
spacer dampers
(Nut Cracker type)
at ( Salvi, Italy &
EGU HV Lab, Czech
),from 21/11/2016G,
to 25/11/2016G. with
test report No.
16/110,10549/A/16,
and 10549/B/16 .

Type test lab: Salvi


test lab, Le
Chambon France.
Date of Tests: 21st
to 22nd October
2019.

3. 1 Page 99 of 763
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CAROBENI
ITALY

PROIZVODNJA MK I OSO d.o.o Innovative Systems Line Hardware up to Tests performed at: PQ Letter
CROATIA (isys) 380 kV Koncar Based on TS&SD fax # 10-01179-03032301
PO Box 60606 Riyadh Croatia, EGU Czech dated April 20, 2010, this manufacturer is
Croatia, Europe, Vukomericka 9, 10410 11555,KSA Republic, pre-qualified for Line Hardware except Spacer
Velika Gorica Zagreb , Croatia/Hrvatska Phone - ZKU, KERI & Bazet Dampers with the following conditions:
+966-11-460-8161 HV
Contact Person - Mr. Davor Maljkovic, Email - [email protected] Laboratories WARRANTY:
B.Sc. M.E. Ten (10) years extended warranty/guarantee in
Phone - +385 1 62 29 900 respect of defects due to design, manufacture,
Email ID - installation & workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
Website - first turnkey project in case of contract award or
http://www.dalekovod-proizvodnja.co date of first delivery in case of direct material
m , http://www.dalekovod.hr supply order.

PreviouslyDALEKOVOD-Croatia. The name has


been changed based on S&SD/P&SFD letter #
12-01292-30504401 dated April 10, 2012.

Previously Dalekovod Proizvodnja [The name has


been changed based on letter #
19-01423-30504401 dated 16 May 2019].

3. 1 Page 100 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DAMP - Spacer Dampers & Vibration Dampers - Tests performed


ITALY upto 380kV at: Demont, EGU &
- Spacer Damper type (Twin) with manufacturer’s lab.
Ia Leonardo Da Vinci 15 24060 drawing # 2.45.33.02 Rev.01 (2010) Report #
Carobbio Degli Angeli Bergamo -Italy - Spacer Damper type (Quad) with 750-AB10-50024,
drawing # 4.45.33.09 Rev.03 954-AB13-50039,
Contact Person - Mr. Francesco Santelli 392-801699,
Phone - +39-35-959390 335-629, 608-860,
Email ID - [email protected] 793-AB11- 50003,
Website - http://www.damp.it 824-AB12-50005,
945-AB13-50039.
- Type tests were
conducted on
spacer dampers
(Nut Cracker type)
at ( Damp, Italy &
Demont Lab,
Italy),from
28/11/2016G, to
01/12/2016G. with
test report No.
1050-SEC Quad
NCK and No.
1051-SEC Twin
NCK.

DERVAUX Previously "SM-CI-France", the name has been


FRANCE change to DERVAUX-France based on
DERVAUX-France letter # Nil dated 13/10/2009.
Le Chambon

Website -
http://www.dervaux-distribution.fr/

3. 1 Page 101 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MOSDORFER GMBH Innovative Systems 1) 380kV Strings


AUSTRIA (ISys) i) Power arc test
Mr. Kamal M. AL reports
Mosdorfergasse 1, 8160 Weiz, Austria MUHANNA; CEO 12-116, 12-117
Phone: +43 3172 2505-341 +966 11 460 8161 Ext. 14-222, 5202-17
Fax: +43 3172 2505-29 111; +966 5 054 91067 5016-20, 5015-20
[email protected]
Contact Person - Darijo Kusanovic ii) Electrical test
(Area Sales Manager) reports
Contact Person Email ID - 9836/A/12,
[email protected] 9836/B/12
Website - www.mosdorfer.com 10154/D/14,
10702/A/17
10702/B/17,
11311/A/20

2) 132kV Strings
i) Power arc test
reports
8630/VNL,
8631/VNL
8711/VNL,
8717/VNL
13-035, 13-036
5008-16, 5009-16

ii) Electrical test


reports
8602/VNL,
8605/VNL
8742/VNL,
8743/VNL
9844/A/12,
9844/B/12

3) 115kV Strings
i) Power arc test
reports
8628/VNL,
8629/VNL

ii) Electrical test

3. 1 Page 102 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

reports
8600/VNL,
8601/VNL

NUOVA ELETTROMECCANICA SUD Dopa Co. for Trading and - Line Hardware upto 380kV Some of tests PQ Letter
S.P.A, industry - Spacer Damper type (Twin) with mutually ageed Based on S&SD letter # 15-06603-030504401
ITALY Al Nuzha District Riyadh, drawing # 8.40.N2.888 Rev.05 between National dated August 13, 2015 it is pre-qualified for
Saudi Arabia P.O Box - Spacer Damper type (Quad) with Grid SA & NES were Hardware Fittings, as conforming to National Grid
Zona Industriale - 89052 Campo 87017 Code No. 11462 drawing # 8.40.N4.864 Rev.05 conducted during SA specification12-TMSS-01 with the following
Calabro (Rc) - Italy Mr. Abdullah Alabdullah plant survey visit conditions:
Deputy General Manager from 8th to 11th
Phone - +39 0965.792.111 (6 line) - Email/ June, 2015. NOTE:
Telefax +39 0965.792.222 alabullah@dopacompany Each new design of Line Hardware & Fittings
Email ID - [email protected] .com which has not been tested before, shall be type
Website - http://www.nesspa.it (+966) 11 2694609 , Type tests were tested per latest revision of 12-TMSS-01.
Mobile:(+966) 50 conducted on
4449933 spacer dampers WARRANTY:
(Nut Cracker type) Ten (10) years Extended Warranty from the date
at NES Factory Italy of PAC of the first turnkey project in case of
and Demont contract award or date of first delivery in case of
Laboratory, Italy direct material supply order shall be applicable for
from 24th July to the Line Hardware to be supplied to SEC/National
28th July, 2016 with Grid SA, as confirmed through letter # Rome,
Test Report No. TR dated 14.11.2014.
SPAT 16/024, dt:
July, 2016

3. 1 Page 103 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFISTERER Line Hardware up to 380 kV 1) 380kV Strings PREVIOUSLY SEFAG AG


SWITZERLAND i) Power arc test
reports Location has been changed from Malters to
Kussnacht 5074-19, 5075-19 Kussnacht
5065-20, 5066-20
Contact Person - Mr. Thomas 5052-18, 5083-19
Bachmann
Phone - Phone: +41 41 499 74 07, Fax: ii) Electrical test
+41 41 497 34 73 reports
Contact Person Email ID - 11109/A/19,
[email protected] 11109/B/19
Website - http://www.pfisterer.com/ 11294/A/19,
11294/B/19

2) 132kV Strings
i) Power arc test
reports
5229-17, 5230-17

ii) Electrical test


reports
10675/A/17,
10675/B/17,
10675/C/17

3. 1 Page 104 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PREFORMED LINE PRODUCTS (PLP) M/s Al Abdulkarim - AGS Suspension Clamp & Spacer Type tests PQ Letter
United Kingdom Holding Co. Riyadh Damper(Twin/Quad) up to 380 kV performed during Based on S&SD letter # 15-09419-1-30504401
Riyadh KSA - Spacer Dampers type (Quad) with plant survey visit dated November 18, 2015, it is pre-qualified for
East Portway, Andover, Hampshire drawing # SDNCU 8044527V Rev. E from 08th to 11th AGS Suspension Clamp & Spacer Damper
Sp10 3Lh England September 2015 at (Twin/Quad) up to 380KV as conforming to
[email protected] Preformed Line National Grid SA specification # 12-TMSS-01.
Product Lab
Contact Person - Mr. Mohamed Atif and Hampshire, England WARRANTY:
Mr. Stephen (Report Ten (10) years extended warranty from the date
Email ID - [email protected], #TR(GB)No:3060) , of PAC of the first turnkey project in case of
[email protected] # TR- 3061 Rev.2) & contract award or date of first delivery in case of
[email protected] 8730/VNL. direct material supply order.
Website - http://www.preformed.com
Type tests were
conducted on
spacer dampers
(Nut Cracker type)
at PLP (GB) Ltd. ,
ANDOVER UK, from
31 Oct 2016,to 1st
Nov 2016.with test
report No. TR(GB)
No. 3314-E dated
1st Nov 2016 ,TR
(GB) No. 3312-E
dated 31 Oct 2016
and TR(GB) No.
3313-E dated 31 Oct
2016.

PREFORMED LINE PRODUCTS (PLP)


United States

SICAMEX
FRANCE

Feugerolle & Pompadour , France

Website - http://
http://www.sicame.com/HTML
FR/filiales sicamex.htm

3. 1 Page 105 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

INDUSTRIAS ARRUTI
SPAIN

Website -
http://www.grupoarruti.com/empresa.a
sp

ISELFA Disqualified due to failure in type testing and


ITALY serious quality control issues.

Website - http://www.iselfa.it/

SA RA ENERGY, CONSTRUCTION, Line Hardware up to 380kV & Tests performed at: Based on S&SD letter# 14-09052-01-30504401
TRADE AND INDUSTRY CO. INC. Twin Spacer Dampers up to 132kV Veiki-VNL Lab. dated 11th December 2014 ,TS&SD fax #
TURKEY Budapest, Hungary 09-00087-03032301 dated 11/01/2009
(Corona/RIV, Power pre-Qualified for Line Hardware up to 380kV and
Plant -Polatli (Ankara) & Adana Arc & Tensile Twin Space Damper up to 132kV with the
(Aadna), Turkey Strength with following conditions:
4-bundle ACAR &
2-bundle ACSR/AW
Conductors WARRANTY:
(Dec. 2012 & April, Ten (10) years extended warranty/guarantee in
2013) respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order

HUBBELL POWER SYSTEMS, INC. Previously A B CHANCE [The name has been
United States changed based on S&SD/P&SFD letter#
14-010193-30504401 dated January 06, 2015
Plant -Columbia , United States and based on Hubbell Power System Grid Letter
# Nil dated December 18, 2014]

3. 1 Page 106 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

POWER TRANSMISSION AND Nutcracker Type Quad Spacer Damper Type Tests PQ Letter
TELECOMMUNICATION EQUIPMENTS Drawing No.182 954-454 Performed: Based on S&SD 18-02112/02-30504401 dated
FACTORY (P.T.E. CO.) (CEPCO) VEIKI Test Report # October 01, 2019, the manufacturer is
Saudi Arabia Nutcracker Type Twin Spacer Dampers 10876/VNL dated prequalified for Spacer Damper and Stockbridge
Drawing No.182 954-114 & 182 15-07-2019 Vibration Damper as conforming to National Grid
Plant -Jeddah Industrial City : P.O Box 954-115 SGS Inspection SA specification # 12-TMSS-01 Rev.02, with the
8234 Jeddah 21482 Plant: Plot No. Report # 109556 following conditions:
1&2, Al-Mahjar Street, Industrial Stock bridge vibration dampers
182-025-252 (OPGW) Laboratory: EGU HV CONDITION:
Marketing Office: 182-025-352 (Conductor) Type test Report : Fresh Type Tests shall be conducted on
M/s Pfisterer Switzerland 182-025-362 (OPGW) 11576/21 dated Stockbridge Vibration Damper and each new
Werkstrasse 7, 6102 Malters, Schweiz, 22-01-2021 design of Spacer Dampers per latest standard
Switzerland 12-TMSS-01 at an independent testing laboratory
VEIKI VNL in the presence of (03) SEC/National Grid SA
Contact Person: Laboratory Reports: representatives and one approved third party
Mr. Thomas Bachmann 13073/VNL, inspector during first SEC/ National Grid SA
Phone: +41 41 499 7407 13074/VNL & project/ order and all cost pertaining to tests shall
Cell: +41 79 686 3691 13075/VNL dt: July be borne by the manufacturer. This has been
[email protected] 17, 2023 confirmed in writing by the manufacturer through
12909/VNL dt: June letter # PTE/TT/SDSD-190909 dated 16
Jeddah 12, 2023 September 2019.

Contact Person - Eng. Mohammad WARRANTY:


Saleem Mir (General Manager); Mr. Ten (10) years extended warranty from the date
Faisal Jandali of PAC of the first turnkey project (in case of
Phone - +966 1260 95165; +966 595 contract award) or date of first delivery (in case
3323 74; +966126608629; of direct material supply order), as confirmed,
+966504661072 through their Letter No. PTE/TT/SDSD-190908
Email ID - [email protected] dated 16 September 2019. shall be applicable for
Website - www.pte-sa.com the equipment to be supplied to SEC/National Grid
SA

Total = 18

CONDUCTOR FITTINGS
3. 2
COMPRESSION TYPE CONNECTORS FOR OVERHEAD TRANSMISSION LINES Applicable Standards: 12-TMSS-02

3. 2 Page 107 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALCOA
United States

Website -
http://www.alcoa.com/usa/en/home.as
p

A SALVI & C S.r.l Type test lab: Salvi Previous location was "Italy", the location has
FRANCE test lab, Le been change to "France" based on letter #
Chambon France. 20-00200-030504401 dated 21.1.2020.
Le Chambon plant, France Date of Tests: 21st
to 22nd October
Contact Person - Mr. Giovanni Sangalli 2019.
(Technical Manager)
Phone - +3902.376715.1, Fax +39
02.376715.222
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - http://www.salvi.eu

CAROBENI
ITALY

3. 2 Page 108 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PROIZVODNJA MK I OSO d.o.o Innovative Systems PQ Letter


CROATIA (isys) Based on TS&SD fax # 10-01179-03032301
PO Box 60606 Riyadh dated April 20, 2010, this manufacturer is
Croatia, Europe, Vukomericka 9, 10410 11555 pre-qualified for Compression Type Connectors
Velika Gorica Zagreb , Croatia/Hrvatska Phone - with the following conditions:
+966-11-460-8161
Contact Person - Mr. Davor Maljkovic, Email - [email protected] CONDITION:
B.Sc. M.E. Each new design of Compression Type
Phone - +385 1 62 29 900 Connectors for OHTL which has NOT been type
Email ID - tested/supplied to SEC before, shall be type
[email protected] tested as per 12-TMSS-02.
Website -
http://www.dalekovod-proizvodnja.co WARRANTY:
m , http://www.dalekovod.hr Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of PAC
of the first turnkey project in case of contract
award or date of first delivery in case of direct
material supply order.

Previously DALEKOVOD – Croatia. [The name


has been changed based on S&SD/P&SFD letter
# 12-01292-30504401 dated April 10, 2012].

Previously Dalekovod Proizvodnja [The name has


been changed based on letter #
19-01423-30504401 dated 16 May 2019].

3. 2 Page 109 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NUOVA ELETTROMECCANICA SUD Dopa Co. for Trading and Overhead Line Compression type PQ Letter
S.P.A, industry connectors Based on S&SD letter # 15-06603-030504401
ITALY Al Nuzha District Riyadh, dated August 13, 2015 it is pre-qualified for
Saudi Arabia P.O Box Overhead line compression type Connectors, as
Zona Industriale - 89052 Campo 87017 Code No. 11462 conforming to National Grid SA specifications #
Calabro (Rc) - Italy Mr. Abdullah Alabdullah 12-TMSS-02
Deputy General Manager
Phone - +39 0965.792.111 (6 line) - Email/ Note:
Telefax +39 0965.792.222 alabullah@dopacompany Each new design of Overhead Line Compression
Email ID - [email protected] .com type Connectors which has not been tested,
Website - http://www.nesspa.it (+966) 11 2694609 shall be type tested as
,Mobile:(+966) 50 per latest revision of 12-TMSS-02.
4449933
WARRANTY:
Ten (10) years Extended Warranty from the date
of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order shall be applicable for
the Compression type Connectors, to be supplied
to SEC/National Grid SA as confirmed through
letter # Nil dated 14.11.2014.

PFISTERER PREVIOUSLY SEFAG AG


SWITZERLAND
Location has been changed from Malters to
Kussnacht Kussnacht

Contact Person - Mr. Thomas


Bachmann
Phone - Phone: +41 41 499 74 07, Fax:
+41 41 497 34 73
Contact Person Email ID -
[email protected]
Website - http://www.pfisterer.com/

SICAMEX
FRANCE

Feugerolle & Pompadour , France

Website - http://
http://www.sicame.com/HTML
FR/filiales sicamex.htm

3. 2 Page 110 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BURNDY
United States

Website -
http://portal.fciconnect.com/portal/page/
portal/FcicntPublic/BurndyWeldMenu

ABB Installation products INC Ahmed Hussain Shaik. ; Previously ELASTIMOLD [The name has been
United States Product Marketing changed based on letter # 19-02239-30504401
Manager dated 02.09.2019].
Plant -Hackettstown +966 122242700 Ext.
2708; +966 59 4788038
1 Esna Drive. ZIP Code 07840 [email protected]
.com
Hackettstown, New Jersey

Contact Person - Steve Wright, Plant


Manager - Hackettstown
Phone - +1 (908) 813 2108
Contact Person Email ID -
[email protected]
Website -
https://clicktime.symantec.com/3AZ685
M1D5FgLQKugPeKq3b6H2?u=www.ab
b.com

HOMAC
United States

Website - http://www.homac.com/

INDUSTRIAS ARRUTI
SPAIN

Website -
http://www.grupoarruti.com/empresa.a
sp

3. 2 Page 111 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SBI Corona/RIV, Heat PQ Letter


SPAIN Cycle/CCT, Based on S&SD letter # 15-04947-30504401
Mechanical, Short dated June 09, 2015, it is prequalified for
Circuit and Substation Connectors (Bolted, Welded &
Temperature Rise Compression type up to 380kV).
Tests were
conducted at
various laboratories
including BAZET,
ZKU, KEMA and
L.C.O.E.

SM-CI PREVIOUSLY AS FCI(SAAE), FRANCE.


FRANCE

Le Chambon

Website - http://www.smci-fc.fr/

ISELFA Disqualified due to failure in type testing and


ITALY serious quality control issues.

Website - http://www.iselfa.it/

LORUNSER AUSTRIA GMBH Substation Connectors (Bolted, Tests performed at PQ Letter


AUSTRIA Welded, and Compression type) Veiki-VNL Budapest Based on S&SD letter# 13-062982-2-30504401
Hungary Lab & dated December 04, 2013, it is pre-qualified for
Bahnhofstrasse 9 6824 Schlins City – Manufacturer’s lab Substation Connectors (Bolted, Welded, &
Austria Factory Location: Ml Production in 2013 (Corona/RIV, Compression types) upto 380kV, with the
Myjava - Slovakia Schlins , Slovakia Fault Current, Heat following conditions
Cycle & Electrical
Contact Person - Mr. Abderrahim Resistance Tests, WARRANTY:
kahkah Mechanical tests) Ten (10) years extended warranty/guarantee in
Phone - +43 5524 829 147 Report No. EN respect of defects due to design, manufacture,
Email ID - [email protected] 10204-2.2 , S30032, installation & workmanship from the date of
Website - 7215/VNL, Provisional Acceptance Certificate (PAC) of the
http://www.loruenser-substations.com 7216/VNL, first turnkey project in case of contract award or
7244/VNL, date of first delivery in case of direct material
7245/VNL, supply order, as confirmed by the manufacturer
7246/VNL, thru letter #nil, dt: Nov 02, 2009..
7247/VNL,
7248/VNL,

3. 2 Page 112 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MOSDORFER Innovative Systems


AUSTRIA (ISys)
Mr. Kamal M. AL
Mosdorfergasse 1, 8160 Weiz, Austria MUHANNA; CEO
+966 11 460 8161 Ext.
Contact Person - Darijo Kusanovic 111; +966 5 054 91067
(Area Sales Manager) [email protected]
Phone - Phone: +43 3172 2505-341
,Fax: +43 3172 2505-29
Contact Person Email ID -
[email protected]
Website - http://www.mosdorfer.com/

SA RA ENERGY, CONSTRUCTION, Compression Connectors up to 380kV Tests performed at: PQ Letter


TRADE AND INDUSTRY CO. INC. Veiki-VNL lab Based on S&SD letter# 14-09052-01-30504401
TURKEY Budapest, Hungary dated 11th December 2014 & TS&SD fax #
(Corona/RIV, Heat 09-00087-03032301 dated 11/01/2009
Plant -Polatli (Ankara) & Adana Cycle, Fault Current prequalified for Compression Connectors up to
(Aadna), Turkey & Tensile Strength 380kV with the following conditions:
with ACAR &
ACSR/AW WARRANTY:
conductors Ten (10) years extended warranty/guarantee in
(November, 2012 & respect of defects due to design, manufacture,
June, 2013) installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

Total = 17

CONDUCTOR FITTINGS
3. 3
OBSTRUCTION MARKERS AND WARNING LIGHTS Applicable Standards: 12-TMSS-03

3. 3 Page 113 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DERVAUX Spherical Marker The first batch of obstruction markers and


FRANCE warning lights shall be type tested in the
Phase Conductor Warning Lights presence of (03) National Grid Saudi Arabia / SEC
Le Chambon Engineers and one approved third party
Tower Beacon Warning Lights inspector. All cost pertaining to tests shall be
Website - borne by the manufacturer.
http://www.dervaux-distribution.fr/
WARRANTY

Ten (10) years extended warranty in respect of


defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), shall be provided by
manufacturer against first supply.

SM-CI Spherical Marker PREVIOUSLY AS FCI (SAAE), FRANCE.


FRANCE
Phase Conductor Warning Lights The first batch of obstruction markers and
Le Chambon warning lights shall be type tested in the
Tower Beacon Warning Lights presence of (03) National Grid Saudi Arabia / SEC
Website - http://www.smci-fc.fr/ Engineers and one approved third party
inspector. All cost pertaining to tests shall be
borne by the manufacturer.

WARRANTY

Ten (10) years extended warranty in respect of


defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), shall be provided by
manufacturer against first supply.

3. 3 Page 114 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BP SOLAR ARABIA LTD Spherical Marker The first batch of obstruction markers and
Saudi Arabia warning lights shall be type tested in the
Phase Conductor Warning Lights presence of (03) National Grid Saudi Arabia / SEC
Website - Engineers and one approved third party
http://www.bpsarabia.com.sa/ Tower Beacon Warning Lights inspector. All cost pertaining to tests shall be
borne by the manufacturer.

WARRANTY

Ten (10) years extended warranty in respect of


defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), shall be provided by
manufacturer against first supply.

OBSTA Innovative Systems Spherical Marker CITEL Test Report # WARRANTY


FRANCE (isys) LER-21-018_B dated
PO Box 60606, Riyadh Phase Conductor Warning Lights February 10, 2021 Ten (10) years extended warranty in respect of
Website - http://www.obsta.com 11555 KSA (Spherical Marker). defects due to design, manufacturing and
+966-11-460-8161 Tower Beacon Warning Lights workmanship from the date of PAC of the first
Email - [email protected] VEIKI VNL Test turnkey project (in case of contract award) or
Report # 10856/VNL from the date of first delivery (in case of direct
dated June 04, 2019 material supply order), shall be provided by
(Phase Conductor manufacturer against first supply.
warning light).

STAC Test Report #


RES/STAC/SE/E/VIS/
OBA-OBS03-18/18-
5516 (Tower
Beacon Light)

3. 3 Page 115 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

P&R TECHNOLOGIES Spherical Marker The first batch of obstruction markers and
United States warning lights shall be type tested in the
Phase Conductor Warning Lights presence of (03) National Grid Saudi Arabia / SEC
Website - http://www.pr-tech.com/ Engineers and one approved third party
Tower Beacon Warning Lights inspector. All cost pertaining to tests shall be
borne by the manufacturer.

WARRANTY

Ten (10) years extended warranty in respect of


defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), shall be provided by
manufacturer against first supply.

PFISTERER SEFAG Spherical Marker (600 mm) Pfisterer Type Test PREVIOUSLY SEFAG AG
SWITZERLAND Report # 04/987
Rev. C dated WARRANTY
Contact Person - Mr. Thomas December 13, 2006
Bachmann (Spherical Marker) Ten (10) years extended warranty in respect of
Contact Person Email ID - defects due to design, manufacturing and
[email protected] workmanship from the date of PAC of the first
Website - http://www.pfisterer.com/ turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), shall be provided by
manufacturer against first supply.

3. 3 Page 116 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Shin Seong Elrex Corp. Spherical Marker (SW-600/500) KERI Test Reports # WARRANTY
SOUTH KOREA 2018TS02263 &
Phase Conductor Warning Lights 2018TS02264 dated Ten (10) years extended warranty in respect of
Phone - Tel : +82 31 493 2911 Fax : November 16, 2018 defects due to design, manufacturing and
+82 31 491 1875 Tower Beacon Warning Lights (Spherical Markers). workmanship from the date of PAC of the first
Contact Person Email ID - turnkey project (in case of contract award) or
[email protected] KERI Test Report # from the date of first delivery (in case of direct
2018TC00664 dated material supply order), shall be provided by
September 21, 2018 manufacturer against first supply.
(Conductor Warning
Lights).

KIL Test Report #


T2104-F02735 dated
April 08, 2021
(Tower Beacon
Warning Lights).

TANA WIRE MARKER Spherical Marker The first batch of obstruction markers and
United States warning lights shall be type tested in the
Phase Conductor Warning Lights presence of (03) National Grid Saudi Arabia / SEC
Website - Engineers and one approved third party
http://www.tanawiremarker.com/ Tower Beacon Warning Lights inspector. All cost pertaining to tests shall be
borne by the manufacturer.

WARRANTY

Ten (10) years extended warranty in respect of


defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), shall be provided by
manufacturer against first supply.

Total = 8

CONDUCTOR FITTINGS
3. 4
Splice & Termination Kits for Power Cable up to 132 KV Applicable Standards: 12-TMSS-10

3. 4 Page 117 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES Transition Joint •Testing Dates : 29th PREVIOUSLY LG


SOUTH KOREA Drawing # : UEMD13Q001 of June to 29th of
Size : 630-1200 mm2 August 2017 PQ letter:
Plant -Gumi/Korea Rating: 123kV •Witness Dates: Based on S&SD letter # 17-08209-30504401
21st to 29th of dated December 03, 2017, LS Cables- South
13 F Ls Tower ,127, Ls-Ro, August 2017 Korea is pre-qualified for Splice and Termination
Dongan-Gu, Anyang-Si, Gyeonggi-Do, 1. GIS Termination : •Test Laboratory : Kits as conforming to latest National Grid SA
Korea Kinetrics, Canada specification # 12-TMSS-10
a. Model Name: UEPG13Q002 (Dry •Report Nos :
Contact Person - Jiyup Baik Type) Kinetrics : WARRANTY:
Phone - +82-544697602 Drawing # : UEPG13Q002 K-423688-DOC-000 •Ten (10) years extended warranty/guarantee in
Email ID - [email protected] Revision : 0 0 R00 respect of defects due to design, manufacture,
Website - http://www.lscns.com Size : 2500 mm² SGS : installation and workmanship from the date of
B-50/2017-0047/014 Provisional Acceptance Certificate (PAC) of the
b. Model Name: UEPG13Q003 (Dry -IR01 first turnkey project in case of contract award or
Type Plugin) date of first delivery in case of direct material
Drawing # : UEPG13Q003 supply order, as confirmed by the manufacturer
Revision : 0 vide letter # LSOF-20150727/00, dated July 27,
Size : 2500 mm² 2017.

2. Transformer Termination :

a. Model Name: UEPO13Q001 (Dry


Type)
Drawing # : UEPO13Q001
Revision : 0
Size : 2500 mm²

b. Model Name: UEPO13Q002 (Dry


Type Plugin)
Drawing # : UEPO13Q002
Revision : 0
Size : 2500 mm²

3. Outdoor Termination:

a. Model Name: UEMA13Q002


(Porcelain)
Drawing # : UEMA13Q002
Revision : 0
Size : 2500 mm²

3. 4 Page 118 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

4. Cross Bonding Joint:

a. Model Name: UEMK13Q001


Drawing # : UEMK13Q001
Revision : 0
Size : 2500 mm²

3. 4 Page 119 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SUDKABEL Mass Power Contracting Termination ( Dry Type Plugin) Type Tests PQ Letter
GERMANY Co. successfully Model: EHFV 170
Unit 2, Building 6429, a. Model Name: EHSVS 123 (A) completed at (IPH Based on S&SD Letter # 21-01247-30504401
Website - http:// Sybawyah Street, Drawing No. : 0.360.88.1a Berlin - Germany) – dated November 23, 2021, Manufacturer is
http://www.suedkabel.de/index e.htm Al-Dana District, Size : Up to 1600 mm² from 10/08/2020 to pre-qualified for Splice & Termination Kits for
Dammam, Saudi Arabia Rating : 123 kV 17/03/2021, Test Power Cable up to 132 KV as conforming to
report No. National Grid SA Specification # 12-TMSS-10 with
Mr. Syed Ali Baqar b. Model Name: EHSVS 123 (B) (11293-20-0478-1). the following conditions:
(Director Business Drawing No. : 0.360.88.1a
Development) Size : 630 to 2500 mm²
+966-13-8462336/ Rating : 123 kV Warranty:
+966-50-6818743 Ten (10) years extended warranty from the date
[email protected] c. Model Name: EHSVS 123 (A) of PAC of the first turnkey project (in case of
Drawing No. : 0.360.88.7a contract award) or date of first delivery (in case
Size : Up to 1600 mm² of direct material supply order). as confirmed,
Rating : 123 kV through their letter No. Nil dated June 05, 2021,
shall be applicable for the equipment to be
d. Model Name: EHSVS 123 (B) supplied to SEC/National Grid SA.
Drawing No. : 0.360.88.7a
Size : 630 to 2500 mm²
Rating : 123 kV PQ Letter
Based on S&SD letter # OMPQ4580213-Class I(a)
e. Model Name: EHSVS 145 (A) -2018 dated August 15, 2021, the manufacturer
Drawing No. : 0.360.88.1a is prequalified for Splice & Termination Kits for
Size : Up to 1600 mm² Power Cable up to 132kV confirming to National
Rating : 145 kV Grid SA specification # 12-TMSS-10 with the
following conditions:
f. Model Name: EHSVS 145 (B)
Drawing No. : 0.360.88.1a WARRANTY
Size : 630 to 2500 mm² Ten (10) years extended warranty from the date
Rating : 145 kV of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
g. Model Name: EHSVS 145 (A) of direct material supply order), as confirmed,
Drawing No. : 0.360.88.7a through their Letter No. Nil dated July 14, 2020
Size : 0 to 1600 mm² shall be applicable for the equipment to be
Rating : 145 kV supplied to SEC/National Grid SA.

h. Model Name: EHSVS 145 (B)


Drawing No. : 0.360.88.7a
Size : 630 to 2500 mm² PREVIOUSLY ABB.
Rating : 145 kV Including Joints & Terminations

3. 4 Page 120 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

i. Model Name: EHSVS 123 (D)


Drawing No. : 0.350.87.9a
Size : Up to 800 mm²
Rating : 123 kV

j. Model Name: EHSVS 145 (D)


Drawing No. : 0.350.87.9a
Size : Up to 800 mm²
Rating : 145 kV

2. GIS Termination (Fluid Filled)

a. Model Name: EHSDV 123


Drawing No. : 0.360.90.0a
Size : Up to 800 mm²
Rating : 123 kV

b. Model Name: EHSDV 145


Drawing No. : 0.360.90.0a
Size : Up to 800 mm²
Rating : 145 kV

c. Model Name: EHSDV 123


Drawing No. : 0.360.90.1a
Size : 1000 to 1600 mm²
Rating : 123 kV

d. Model Name: EHSDV 145


Drawing No. : 0.360.90.1a
Size : 1000 to 1600 mm²
Rating : 145 kV

e. Model Name: EHSDV 123


Drawing No. : 0.360.06.0a
Size : 1600 to 2500 mm²
Rating : 123 kV

f. Model Name: EHSDV 145


Drawing No. : 0.360.06.0a
Size : 1600 to 2500 mm²
Rating : 145 kV

3. 4 Page 121 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

3. Transformer Termination ( Dry


Type Plugin)

a. Model Name: EHTVS 123 (A)


Drawing No. : 0.360.95.0a
Size : Up to 1600 mm²
Rating : 123 kV

b. Model Name: EHTVS 123 (B)


Drawing No. : 0.360.95.0a
Size : 630 to 2500 mm²
Rating : 123 kV

c. Model Name: EHTVS 145 (A)


Drawing No. : 0.360.95.0a
Size : Up to 1600 mm²
Rating : 145 kV

d. Model Name: EHTVS 145 (B)


Drawing No. : 0.360.95.0a
Size : 630 to 2500 mm²
Rating : 145 kV

e. Model Name: EHTVS (D) 123


Drawing No. : 0.350.96.0a
Size : Up to 800 mm²
Rating : 123 kV

f. Model Name: EHTVS (D) 145


Drawing No. : 0.350.96.0a
Size : Up to 800 mm²
Rating : 145 kV

g. Model Name: EHTVS 123 (A)


Drawing No. : 0.360.95.2a
Size : Up to 1600 mm²
Rating : 123 kV

h. Model Name: EHTVS 123 (B)


Drawing No. : 0.360.95.2a
Size : 630 mm² to 2000 mm²

3. 4 Page 122 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Rating : 123 kV

i. Model Name: EHTVS 123 (B-2500)


Drawing No. : 0.360.95.2a
Size : Up to 2500 mm²
Rating : 123 kV

j. Model Name: EHTVS 145 (A)


Drawing No. : 0.360.95.2a
Size : Up to 1600 mm²
Rating : 145 kV

k. Model Name: EHTVS 145 (B)


Drawing No. : 0.360.95.2a
Size : 630 mm² to 2000 mm²
Rating : 145 kV

l. Model Name: EHTVS 145 (B-2500)


Drawing No. : 0.360.95.2a
Size : Up to 2500 mm²
Rating : 145 kV

4. Transformer Termination ( Fluid


Filled)

a. Model Name: EHTV 123


Drawing No. : 0.360.85.0a
Size : Up to 1600 mm²
Rating : 123 kV

b. Model Name: EHTV 145


Drawing No. : 0.360.85.0a
Size : Up to 1600 mm²
Rating : 145 kV

c. Model Name: EHTV 123


Drawing No. : 0.360.86.0a
Size : 1600 to 2500 mm²
Rating : 123 kV

d. Model Name: EHTV 145


Drawing No. : 0.360.86.0a

3. 4 Page 123 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Size : 1600 to 2500 mm²


Rating : 145 kV

5. Outdoor Termination (Porcelain)

a. Model Name: EHFV 145


Drawing No. : 0.36.72.13a
Size : Up to 2500 mm²
Rating : 145 kV
Creepage Distance : 4610 mm

b. Model Name: EHFV 123


Drawing No. : 0.36.72.0a
Size : Up to 2500 mm²
Rating : 123 kV
Creepage Distance : 3860 mm

c. Model Name: EHFV 145


Drawing No. : 0.36.72.0a
Size : Up to 2500 mm²
Rating : 145 kV
Creepage Distance : 4610 mm

d. Model Name: EHFV 145


Drawing No. : 0.36.74.1a
Size : Up to 2500 mm²
Rating : 145 kV
Creepage Distance : 4610 mm

e. Model Name: EHFV 170


Drawing No. : O.36.74.1A
Size : Up to 2500 mm²
Rating : 170 kV
Creepage Distance : 6100 mm

6. Cross Bonding Joint

a. Model Name: SEHDVCB 123


Drawing No. : 0.3600.36.0a
Size : Up to 2500 mm²
Rating : 123 kV

3. 4 Page 124 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

b. Model Name: SEHDVCB 145


Drawing No. : 0.3600.36.0a
Size : Up to 2500 mm²
Rating : 145 kV

c. Model Name: SEHDVCB 123


Drawing No. : 0.3600.36.2a
Size : Up to 2500 mm²
Rating : 123 kV

d. Model Name: SEHDVCB 145


Drawing No. : 0.3600.36.2a
Size : Up to 2500 mm²
Rating : 145 kV

e. Model Name: SEHDVCB 123


Drawing No. : 0.3600.36.4a
Size : Up to 2500 mm²
Rating : 123 kV

f. Model Name: SEHDVCB 145


Drawing No. : 0.3600.36.4a
Size : Up to 2500 mm²
Rating : 145 kV

7. GIS Termination ( Dry Type Plugin


– Fluid Interface)

a. Model Name: EHSVS 123 (A)


Drawing No. : 0.360.88.8a
Size : Up to 1600 mm²
Rating : 123 kV

b. Model Name: EHSVS 123 (B)


Drawing No. : 0.360.88.8a
Size : 630 to 2500 mm²
Rating : 123 kV

c. Model Name: EHSVS 145 (A)


Drawing No. : 0.360.88.8a
Size : Up to 1600 mm²

3. 4 Page 125 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Rating : 145 kV

d. Model Name: EHSVS 145 (B)


Drawing No. : 0.360.88.8a
Size : 630 to 2500 mm²
Rating : 145 kV

DRAKA NK
FINLAND

Website - http://www.draka.com/

DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN

FURUKAWA ELECTRIC CO. LTD.


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

3. 4 Page 126 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB Installation products INC 1. Cross Bonding Joint: Previously ELASTIMOLD [The name has been
United States Model Name : 138TCJS4 changed based on letter # 19-02239-30504401
dated 02.09.2019].
Plant -Hackettstown 2. Cross Bonding Joint:
Model Name : 138TCJS46
1 Esna Drive. ZIP Code 07840 Size : Up to 1200mm²
Drawing # : SD-SEC-1200mm2
Hackettstown, New Jersey Rating: 145kV

Contact Person - Steve Wright, Plant


Manager - Hackettstown
Phone - +1 (908) 813 2108
Contact Person Email ID -
[email protected]
Website -
https://clicktime.symantec.com/3AZ685
M1D5FgLQKugPeKq3b6H2?u=www.ab
b.com

PIRELLI
GERMANY

Berlin , Germany

Website - http://
http://www.pirelli.com/splash/index.htm
l

G&W SUSPENDED FOR ALL ONGOING & FUTURE


United States PROJECTS DUE TO FREQUENT FAILURE & VERY
POOR FOLLOWUP RESPONSE FROM THE
Website - http://www.gwelec.com/ MANUFACTURER.

3. 4 Page 127 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NEXAN Benoit Rollet 1. GIS Termination: Tests performed:


SWITZERLAND Phone - Model Name : TF-1.145 (19-12-2013 to
+33-6-14-99-00-54 Rating: 145kV 16-04-2014)
Website - Email -
http://www.nexans.com/eservice/Navi [email protected] 2. Outdoor Termination:
gate.nxnavigationRef= m Model Name : SOA 1.145
-10&CZ=Corporate Size : Up to 2000 mm²
Rating: 145kV

3. Transformer Termination:
Model Name : SOA 1.145
Rating: 145kV

4. Cross Bonding Joint:


Model Name : MP-123-31
Rating: 123kV

5. Cross Bonding Joint:


Model Name : MP1.145-31
Size : Up to 2000 mm²
Rating: 145kV

6. Transformer Termination (Dry Type ):


Model Name : DTT1.145
Rating: 145kV

7. GIS Termination (Dry Type ):


Model Name : DTF1.145
Rating: 145kV

8. GIS Termination (Fluid-Filled):


Model Name : SFY1.145
Size : Up to 2000 mm²
Rating: 145kV

9. Transformer Termination
(Fluid-Filled):
Model Name : STY1.145
Rating: 145kV

10. Transition Joint:


Model Name : OTSI.145/31

3. 4 Page 128 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Drawing # OTSF31005
Rating: 145kV

NKT (COLOGNE PLANT)NKT CABLES METS Riyadh 1. Outdoor Termination: Type test witnessed PQ Letter
GROUP Mr. Won Koo Kown Model Name : FEV 170-P during 03rd-7th Based on S&SD letter # 15-05202-01-30504401
GERMANY General Manager Size : Up to 2500 mm² November 2014 & 8 dated
,[email protected] Drawing # : 3. 7 5056-04 August,2014 and 14 September 15, 2015, it is pre-qualified as per
Düsseldorfer Strasse 400 Chempark [email protected] Rev: 1 July 2015. KEMA 12-TMSS-10.
51061 Cologne Germany Rating: 170kV Nederland
Test Report WARRANTY:
Phone - +49-0-221-6-760 2. GIS Termination: No1211-15 Ten (10) Extended Warranty/Guarantee for the
Email ID - [email protected] , Model Name : SEV 170 proposed 132 kV cables accessories shall be
[email protected] Size : Up to 2500 mm² provided in respect of the defectsdue to design,
Website - http://www.nktcable.com Drawing # : 3. 7 0264-01 manufacturing, installation and workmanship from
Rev: 1 the date of Provisional Acceptance Certificate
Rating: 170kV (PAC) of the project (in case of contract award)
and from the date of delivery for the direct
3. Transformer Termination: material supply order as confirmed through the
Model Name : TEV 170 manufacturer letter # nil dated June 04, 2013.
Size : Up to 2500 mm²
Drawing # : 3. 7 0263-01
Rev: 1
Rating: 170kV

4. Cross Bonding Joint:


Model Name : SME 145-S-P

Drawing # : 3. 7 8122-01
Rating: 145kV

3. 4 Page 129 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFISTERER IXOSIL 1-Fluid Filled GIS Termination: Type tests were 1- Fluid Filled GIS Termination:
SWITZERLAND conducted in KEMA
a. Model Name : ESG123-V laboratory – a. Approved model as per the range of type
Plant -Pfisterer Ixosil Size : Up to 2000 mm² Netherland from approval from 1121-22 and 1143-22 Type Test
Altdorf/Switzerland Drawing # : PRO2235 09.05.2012 to Reports
Rating: 123kV 19.08.2012.
Pfisterer Ixosil Ag Gotthardstrasse 31 (SGS Type Test
Ch-6460 Altdorf Switzerland b. Model Name : ESG145-V Report 01.13288.02 b. Approved model as per the range of type
Size : Up to 2000 mm² Rev.2 dated 20th of approval from 1121-22 and 1143-22 Type Test
Contact Person - Mr. Nicolas Drawing # : PRO2225 September 2012) Reports.
Stocker/Ms Monika Haensli, Sales and Rating: 145kV
Project Management
Email ID - [email protected] c. Model Name : ESG145-V c. Approved model as per the range of type
Website - http://www.ixosil.ch Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2236 Reports.
Rating: 145kV

d. Model Name : ESG170-V d. Approved model subject to successfully


Size : Up to 2000 mm² performing the required type test.
Drawing # : PR02227
Rating: 170kV

e. Model Name : ESG123-V e. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 Type Test Report.
Drawing # : PRO2226
Rating: 145kV

f. Model Name : ESG123-H f. Approved model as per the range of type


Size: Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2228 Reports.
Rating: 123 kV

g. Model Name : ESG170-V g. Approved model subject to successfully


Size : 1600 - 2500 mm² performing the required type test.
Drawing # : PR02501
Rating: 170kV

h. Model Name : ESG145-H h. Approved model as per 1567-18 and 1121-22


Size : Up to 2000 mm² Type Test Reports
Drawing # : PRO2229 Previous drawing # is PRO00171
Rating: 145kV

3. 4 Page 130 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

i. Model Name : ESG145-V i. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 Type Test Reports
Drawing # : PRO80652
Rating: 145kV

j. Model Name : ESG145-V j. Approved model as per the range of type


Size: 1600-2500 mm² approval from 1121-22 Type Test Reports.
Drawing # : PRO80659
Rating: 145kV

k. Model Name : ESG 123-V k. Approved model as per the range of type
Size : 1600-2500 mm² approval from 1121-22 Type Test Report.
Drawing # : PRO2494
Rating: 123 kV

l. Model Name : ESG123-H l. Approved model as per the range of type


Size : 1600-2500 mm² approval from 1121-22 Type Test Report.
Drawing # : PRO2503
Rating: 123 kV

m. Model Name : ESG123-H m. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 Type Test Report.
Drawing # : PRO2313
Rating: 123 kV

n. Model Name : ESG145-V n. Approved model as per the range of type


Size : 1600-2500 mm² approval from 1121-22 Type Test Report.
Drawing # : PRO2488
Rating: 145 kV

o. Model Name : ESG145-H o. Approved model as per 1121-22 Type Test


Size : 1600-2500 mm² Reports Previous drawing # is PRO 2025->2195
Drawing # : PRO2504
Rating: 145 kV

p. Model Name : ESG145-H p. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2312 Reports
Rating: 145 kV

3. 4 Page 131 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

2- Cross Bonding Joint: 2- Cross Bonding Joint:

a. Model Name : MSA123-XKG a. Approval model as per the range of type


Size : Up to 2500 mm² approval from 1121-22 Type Test Report.
Drawing # : 880111333A006 Previous drawing # is PRO 2192.
Rating: 123 kV

b. Model Name : MSA145-XKG b. Approved model as per 1121-22 and 1819-18


Size : Up to 2500 mm² Type Test Reports
Drawing # : 880111333A011 Previous drawing # is PRO 2025->2195
Rating: 145kV

c. Model Name : MSA123-XLG c. Approved model as per the range of type


Size : Up to 2500 mm² approval from 1121-22 Type Test Report.
Drawing # : 880111333A007
Rating: 123 kV

d. Model Name : MSA145-XLG d. Approved model as per the range of type


Size : Up to 2500 mm² approval from 1121-22 Type Test Report.
Drawing # : 880111333A012
Rating: 145 kV

e. Model Name: MSA72-XKG e. Approved model as per the range of type


Size: up to 1600 mm2 approval from 1121-22 Type Test Report.
Drawing #: 880111333A002

f. Model Name: MSA72-XLG f. Approved model as per the range of type


Size: up to 1600 mm2 approval from 1121-22 Type Test Report.
Drawing #: 880111333A003

g. Model Name: MSA170-XKG g. Approved model subject to successfully


Size: up to 2500 mm2 performing the required type test.
Drawing #: 880111333A014

h. Model Name: MSA170-XLG h. Approved model subject to successfully


Size: up to 2500 mm2 performing the required type test.
Drawing #: 880111333A015

3-Straight Through Joint: 3. Straight Through Joint:

a. Model Name : MSA145-DOG a. Approved model as per the range of type


Size : UP to 2500 mm² approval from 1121-22 Type Test Report.

3. 4 Page 132 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Drawing # : 880111333A010 Previous drawing # is PRO 2013-> PRO 2197.


Rating: 145kV

b. Model Name : MSA123-DOG b. Approved model as per the range of type


Size : Up to 2500 mm² approval from 1121-22 Type Test Report.
Drawing # : 880111333A004
Rating: 123 kV

c. Model Name: MSA72-DOG c. Approved model as per the range of type


Size: up to 1600 mm2 approval from 1121-22 Type Test Report.
Drawing #: 880111333A001

d. Model Name: MSA170-DOG d. Approved model subject to successfully


Size: up to 2500 mm2 performing the required type test
Drawing #: 880111333A013

4- Fluid Filled Outdoor Termination: 4- Fluid Filled Outdoor Termination:

a. Model Name : ESP145-C73 a. Approved model as per 1121-22 and 1143-22


Size : 1000 to 2500 mm² Type Test Reports
Drawing # : 880111666A029 Previous drawing # is PRO 2497
Rating: 145kV
b. Approved model as per the range of type
b. Model Name : ESP145-C58 approval from 1819-18 and 1242-15 Type Test
Size : UP to 1200 mm² Reports up to 1200 mm² only. Supplying this
Drawing # : 880111666A027 model on conductor more than 1200 mm² shall be
Rating: 145kV type tested on the 1st project. Previous
drawing # is PRO 2512
c. Model Name : ESP170-C58
Size : UP to 2000 mm² c. Approved model subject to successfully
Drawing # : 880111666A030 performing the required type test.
Rating: 170kV Previous drawing # is PRO 00302

d. Model Name : ESP170-C73 d. Approved model subject to successfully


Size : 1000-2500 mm² performing the required type test.
Drawing # : 880111666A032 Previous drawing # is PRO 2330
Rating: 170kV
e. Approved model as per the range of type
e. Model Name : ESP145-C58 approval from 1819-18 and 1242-15 Type Test
Size : Up to 1200 mm² Reports up to 1200 mm² only. Supplying this
Drawing # : PRO80675 model on conductor more than 1200 mm² shall be
Rating: 145kV type tested on the 1st project.

3. 4 Page 133 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

f. Model Name : ESP145-C58 f. Approved model as per the range of type


Size : Up to 1200 mm² approval from 1819-18 and 1242-15 Type Test
Drawing # : PRO80363 Reports up to 1200 mm² only. Supplying this
Rating: 145kV model on conductor more than 1200 mm² shall be
type tested on the 1st project.

g. Model Name : ESP145-C58 g. Approved model as per the range of type


Size : Up to 1200 mm² approval from 1819-18 and 1242-15 Type Test
Drawing # : 880111666A027 Reports up to 1200 mm² only. Supplying this
Rating: 145kV model on conductor more than 1200 mm² shall be
type tested on the 1st project.

h. Model Name : ESP145-C50 h. Approved model as per the range of type


Size : Up to 1200 mm² approval from 1041-14 Type Test Report up to
Drawing # : 880111666A026 1200 mm² 110 kv only. Supplying this model on
Rating: 145kV conductor more than 1200 mm² and more than
110 KV shall be type tested on the 1st project.
i. Model Name : ESP145-C73
Size : Up to 2000 mm² i. Approved model as per 1567-18 and
Drawing # : 880111666A028 1121-22Type Test Reports
Rating: 145kV Previous drawing # is PRO 00303.

J. Model Name : ESP145-C50 j. Approved model as per the range of type


Size : Up to 1200 mm² approval from 1041-14 Type Test Report up to
Drawing # : PRO80667 1200 mm² 123 kv only. Supplying this model on
Rating: 123 kV conductor more than 1200 mm² and more than
123 KV shall be type tested on the 1st project.
k. Model Name : ESP145-C50
Size : Up to 1200 mm² k. Approved model as per the range of type
Drawing # : PRO80663 approval from 1041-14 Type Test Report up to
Rating: 123 kV 1200 mm² 123 kv only. Supplying this model on
conductor more than 1200 mm² and more than
l. Model Name : ESP145-C73 123 KV shall be type tested on the 1st project.
Size : Up to 2000 mm²
Drawing # : PRO80364 l. Approved model as per the range of type
Rating: 145 kV approval from 1121-22 and 1143-22 Type Test
Reports.
m. Model Name : ESP145-C73
Size : 2000-2500 mm² m. Approved model as per the range of type
Drawing # : PRO 80664 approval from 1121-22 and 1143-22 Type Test
Rating: 145 kV Reports.

3. 4 Page 134 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

5. Fluid Filled Transformer Termination: 5. Fluid Filled Transformer Termination:

a. Model Name : ESU145-V a. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO80661 Reports
Rating: 145kV

b. Model Name : ESU123-H b. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO00231 Reports
Rating: 123 kV

c. Model Name : ESU123-H c. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2289 Reports
Rating: 123 kV

d. Model Name : ESU123-V d. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO00175 Reports
Rating: 123 kV

e. Model Name : ESU123-V e. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2287 Reports
Rating: 123 kV

f. Model Name : ESU123-V f. Approved model as per the range of type


Size : 1600-2500 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2495 Reports
Rating: 123 kV

g. Model Name : ESU145-V g. Approved model as per the range of type


Size : 1600-2500 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2496 Reports
Rating: 145 kV

h. Model Name : ESU145-H h. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2288 Reports

3. 4 Page 135 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Rating: 145 kV

i. Model Name : ESU145-H i. Approval extended as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO00232 Reports
Rating: 145 kV

j. Model Name : ESU145-V j. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO00176 Reports
Rating: 145 kV

k. Model Name : ESU145-V k. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO2286 Reports
Rating: 145 kV

l. Model Name : ESU145-V l. Approved model as per the range of type


Size : Up to 2000 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO80660 Reports
Rating: 145 kV

m. Model Name : ESU145-V m. Approved model as per the range of type


Size : 1600- 2500 mm² approval from 1121-22 and 1143-22 Type Test
Drawing # : PRO80662 Reports
Rating: 145 kV

n. Model Name : ESU170-V n. Approved model subject to successfully


Size : up to 2000 mm² performing the required type test
Drawing # : PRO00177
Rating: 170 kV

o. Model Name : ESU170-V o. Approved model subject to successfully


Size : 1600- 2500 mm² performing the required type test
Drawing # : PRO2502
Rating: 170 kV

RAYCHEM, GERMANY / TE
CONNECTIVITY
GERMANY

Website - http://www.raychem.com/

3. 4 Page 136 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BRUGG CABLE 1. GIS Termination : Tests performed at:


SWITZERLAND KEMA, Netherlands
a. Model Name: TFD1.170-11 (Plugin (2006/2014)
Contact Person - Mr. Amr Soudi; Dry Type)
Regional Sales Manager Drawing # : S 1867-4
Contact Person Email ID - Size : Up to 2500 mm²
[email protected],rolf.aregg Rating : 170 kV
[email protected] Remarks : Test performed at:
Website - KEMA B.V., Netherlands
http://www.bruggcables.com/index/ind Date of tests:
ex.cfmsprache=en 22 March to 25 June, 2018
Test report #1360-18, rev.03

b. Model Name: TF1.170-11


(Fluid-Filled)
Drawing # : S1917-4
Size : 240 mm² to 1200 mm²
Rating : 170 kV

c. Model Name: TF1.170-11


(Fluid-Filled)
Drawing # : S1620-4
Size : Up to 2500 mm²
Rating : 170 kV

d. Model Name: TF1.170-12


(Fluid-Filled)
Drawing # : S1573-4
Size : Up to 2000 mm²
Rating : 170 kV

e. Model Name: TF1.170-12


(Fluid-Filled)
Drawing # : S1916-4
Revision : 2
Size : 1000 mm² to 2500 mm²
Rating : 170 kV

2. Transformer Termination :

a. Model Name: TT1.170-11


Drawing # : S1929-4

3. 4 Page 137 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Size : 240 mm² to 1200 mm²


Rating : 170 kV

b. Model Name: TT1.170-12


Drawing # : S1928-4
Size : 1000 mm² to 2500 mm²
Rating : 170 kV

c. Model Name: TTD 1.170-11 (Plugin


Dry Type)
Drawing # : S 1867-4
Size : Up to 2500 mm²
Rating : 170 kV
Remarks : Approved based on
TFD1.170-11 as there is no difference.

3. Outdoor Termination:

a. Model Name: TE1.145-11


Drawing # : S1919-4
Size : 240 mm to 2500 mm²
Min. Creepage Distance : 4700 mm
Rating : 145 kV
Remarks : Replaced the old model TE
1.145-01 (Drawing # S1538-4 Revision
2)

b. Model Name: TE1.145-12


Drawing # : S1920-4
Size : 240 mm to 2500 mm²
Min. Creepage Distance : 5950 mm
Rating : 145 kV
Remarks : Replaced the old model TE
1.145-01 (Drawing # S1538-4 Revision
2)

c. Model Name: TE1.170-01


Drawing # : S1625-4
Size : Up to 2500 mm²
Min. Creepage Distance : 5950 mm
Rating : 170 kV

3. 4 Page 138 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

4. Straight Through Joint:

a. Model Name: MPP1.145-21


Drawing # : S1379-4
Size : Up to 2000 mm²
Rating : 145 kV

b. Model Name: MPP1.145-22


Drawing # : S1863-4
Revision : 2
Size : Up to 2500 mm²
Rating : 145 kV

5. Cross Bonding Joint:

a. Model Name: MPP1.145-31


Drawing # : S1380-4
Size : Up to 2000 mm²
Rating : 145 kV

b. Model Name: MPP1.145-32


Drawing # : S1862-4
Revision : 2
Size : Up to 2500 mm²
Rating : 145 kV

c. Model Name: MPCC 1.170-31


Drawing # : HM2905
Revision : A0
Rating : 170 kV

6. Transition Joint:

a. Model Name: MPPCC1.170.31


Drawing # : S11973-4
Rating : 170 kV

DAITWEILER
United Kingdom

Website - http://www.duttweiler.de/

3. 4 Page 139 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FUJIKURA VISCAS CORP


JAPAN

Website - http://www.ffcpg.com.my/

ABB
SWITZERLAND

Contact Person - Mr. Klaus Lohse


Phone - +41 58 588 33 50
Email ID - [email protected]
Website - http://www.abb.ch/

3. 4 Page 140 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Electric Wire Co. 1.GIS Termination (Dry Type Plugin): Type tests were PQ Letter:
Saudi Arabia Model Name : GPPS-145-L conducted in KERI Based on S&SD letter # 18-04569-01-30504401
Drawing # : EBG-132-PPS01 laboratory – South dated December 11, 2018, Taihan Electric Wire
Plant -Riyadh Korea. Test Report Co. – Saudi Arabia, Riyadh is pre-qualified for
2.GIS Termination (Fluid Filled) : No. 2019TC00095 132kV Cable Splice & Termination Kits as
Riyadh, Kingdom of Saudi Arabia Model Name : GMFS-145-O dated 04.04.2019. conforming to National Grid SA specification #
P.O. Box 519- Riyadh 11383 Size : 200-1600 mm2 (SGS Type Test 12-TMSS-10, with the following condition:
Drawing # : EBG-132-S02 Rev: A Report 01.14842
Contact Person - Mr. Seung IL, Kim Rev.01 dated Warranty:
(General Manager) 3.GIS Termination (Fluid Filled) : 01.04.2019)” Ten (10) years extended warranty/guaranty
Phone - +966 593 836 444; Model Name : GMFS-145-O from the date of (PAC) of the Turnkey project (In
Email ID - [email protected]; Size : 1600 ~ 2500 mm² case of contract award) and from the date of
Website - www.sauditaihan.com Drawing # : EBG-132-S03 Rev: A delivery for the direct material supply order. The
guarantee/warranty shall be applicable from first
4.Transformer Termination (Fluid Filled) project and shall cover all the cost of materials
: and labor as per warranty/guarantee of materials
Model Name : OMFS-145-O and workmanship and subsequently reduced
Size : 200 ~ 1600 mm² yearly in case of future project award. This was
Drawing # : EBO-132-S02 Rev. A confirmed in writing by Taihan Electric Wire Co.,
Riyadh, Saudi Arabia through their letter #
5.Transformer Termination (Fluid Filled) STL-091/17/K dated # August 28, 2017.
:
Model Name : OMFS-145-O
Size : 1600 ~ 2500 mm²
Drawing # : EBO-132-S03 Rev. A

6.Outdoor Termination:
Model Name : AMPS-145-66
Size : 200 ~ 2500 mm²
Drawing # : EBA-P132-S01 Rev. A

7.Insulation Joint:
Model Name : SMI-145-CS
Size : 200 ~ 2500 mm²
Drawing # : PMJ-132-IJC-CS Rev. A

8.Straight Through Joint:


Model Name : SMN-145-CS
Drawing # : PMJ-132-NJS-CS Rev. A

9.Transformer Termination (Dry Type


Plugin):

3. 4 Page 141 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Model Name: OPPS-145-L


Drawing #: EBO-132-PPS01

PFISTERER Kontaktsysteme GmbH M/s CEPCO Civil & 132KV HV Connex Plug in Dry Type PFISTERER PQ letter:
GERMANY Electrical Projects termination size 6 (including socket) Kontaktsysteme Based on S&SD letter # 17-07474-2-30504401
Contracting Co. with drawing # 866999999A1.3 Rev GmbH-Germany dated November 01, 2017, PFISTERER
Plant -GERMANY P.O Box 8234, Jeddah .01 successfully Kontaktsysteme GmbH-Germany is pre-qualified
21482, KSA conducted type for 132KV Plug-in Dry Type GIS termination
Rosenstrasse 44 73650 Winterbach +966 26634331 tests on 132KV HV conforming to latest National Grid SA
[email protected] Connex 6 GIS Plug in specification # 12-TMSS-10, with the following
Winterbach m Dry Type termination conditions :
(including socket) in
Contact Person - Mr. Andre Goessler, independent test WARRANTY:
Sales Manager & Mr.Stephane wope, laboratory Ten (10) years extended warranty/guarantee in
Technical Advisor (KEMA-Netherland respect of defects due to design, manufacture,
Phone - +49718170050 with report # TIC installation and workmanship from the date of
Email ID - 1072-12) in the Provisional Acceptance Certificate (PAC) of the
[email protected], presence of first turnkey project in case of contract award or
[email protected] SEC/National Grid date of first delivery in case of direct material
Website - www.Pfisterer.de SA Engineers & supply order, as confirmed by the manufacturer
Third Party inspector vide letter # Nil, dated October 24, 2016.

3. 4 Page 142 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution 1. GIS Termination:
KOREA, Republic of Co., Ltd. Branch Model Name : GMF-123-O
P. O. Box 300201, Size : 200-1600 mm2
Plant -Dangjin Factory Riyadh 11372, Office No. Drawing # : EBG-115-S
18, Commercial Complex Rev: A
317, Simin Daero, Dongan-gu Building, King Abdulaziz Rating: 123kV
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia 2. GIS Termination:
+966 11 410 1773 Model Name : GMF-123-O
Contact Person - Jang Hee Lee [email protected] Size : 1600-2500 mm2
Phone - +82 2 316 9190 Drawing # : EBG-115-S01
Email ID - [email protected] Rev: A
Contact Person Email ID - Rating: 123kV
[email protected]
Website - www.taihan.com 3. GIS Termination:
Model Name : GMF-145-O
Size : Up to 1200 mm²
Drawing # : EBG-132-S
Rev: A
Rating: 145kV

4. GIS Termination:
Model Name : CVC-GWO-110-BD
Size : Up to 2500 mm²
Rev: A
Rating: 123kV

5. GIS Termination:
Model Name : CVC-GWO-132-BD
Rating: 145kV

6. Outdoor Termination:
Model Name : AMP-145
Rating: 145kV

7. Outdoor Termination:
Model Name : CVC-APS-1322000A-BD
Rating: 145kV

8. Outdoor Termination:
Model Name : CVC-APS-1322410A-BD
Size : Up to 2500 mm²

3. 4 Page 143 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Rev: A
Rating: 145kV

9. Cross Bonding Joint:


Model Name : CVC-MIP-132-BD
Size : Up to 2500 mm²
Rating: 145kV

10. Cross Bonding Joint:


Model Name : SMI-123-C
Size : 200-2500 mm2
Drawing # : PMJ-115-IJC-C
Rev: A
Rating: 123kV

11. Cross Bonding Joint - Compression


Type :
Model Name : SMI-145-C
Size : Up to 1200 mm²
Drawing # : PMJ-132-IJC-C
Rev: A
Rating: 145kV

12. Cross Bonding Joint - Bolted Type :


Model Name : SMI-145-CS
Drawing # : PMJ-132-IJC-CS
Rev: A
Rating: 145kV

13. Straight Through Joint


-Compression Type:
Model Name : SMN-145-C
Rating: 145kV

14. Straight Through Joint - Bolted


Type:
Model Name : SMN-145-CS
Drawing # : PMJ-132-NJS-CS
Rev: A
Rating: 145kV

15. Cross Bonding Joint:

3. 4 Page 144 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Model Name : SMI-145-X


Drawing # : PMJ-132-15C-C
Rev: A
Rating: 145kV

16. Outdoor Termination:


Model Name : AMC-145
Size : 1200-2500 mm2
Drawing # : EBA-C32-S
Rev: A
Rating: 145kV

17. GIS Termination:


Model Name : GPF-123-C
Size : 1200-2500 mm2
Drawing # : EBG-115-P01
Rating: 123kV

18. Transition joint:


Model Name : SPIC-123-X
Size : 630-1200 mm2
Drawing # : PJ-132-IJC-C
Rating: 123kV

19. GIS Termination - Compression


Type:
Model Name : GMF-145-O
Drawing # : CP-1321200-SG00 ,
CP-132400-SG00
Rating: 145kV

20. GIS Termination - Bolted Type:


Model Name : GMFS-145-O
Drawing # : EBG-132-S03
Rev: A
Rating: 145kV

21. Outdoor Termination - Compression


Type:
Model Name : AMP-145-60
Size : Up to 2500 mm²
Drawing # : CP-1312-SA00

3. 4 Page 145 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Rating: 145kV

22. Outdoor Termination - Compression


Type:
Model Name : AMP-145-70
Size : Up to 2500 mm²
Drawing # : EBA-P132-S01
Rev: A
Rating: 145kV

23. Outdoor Termination - Bolted Type:


Model Name : AMPS-145-46
Size : 200-2500 mm2
Drawing # : EBA-P132-S01
Rev: A
Rating: 145kV

24. Outdoor Termination - Bolted Type:


Model Name : AMPS-145-66
Size : 200-2500 mm2
Drawing # : EBA-P132-S01
Rev: A
Rating: 145kV

25. Transformer Termination:


Model Name : OMF-145-O
Size : Up to 2500 mm²
Drawing # : CP-1312-QSA00
Rating: 145kV

26. Cross Bonding Joint:


Model Name : SMI-145-C
Size : Up to 2500 mm²
Drawing # : XM-1312-SI00
Rating: 145kV

27. Outdoor Termination :


Model Name : AMP-123-60
Size : 200-2500 mm2
Drawing # : EBA-P115-S
Rev: A
Rating: 123kV

3. 4 Page 146 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

28. Transition Joint:


Model Name : CF132T0I
Drawing # : CF132T0I
Rating: 132kV

Total = 20

CONDUCTOR FITTINGS
3. 5
Splice & Termination Kits for Power Cable up to 230 KV Applicable Standards: 12-TMSS-10

SUDKABEL Mass Power Contracting PREVIOUSLY ABB.


GERMANY Co.
Unit 2, Building 6429,
Website - http:// Sybawyah Street,
http://www.suedkabel.de/index e.htm Al-Dana District,
Dammam, Saudi Arabia

Mr. Syed Ali Baqar


(Director Business
Development)
+966-13-8462336/
+966-50-6818743
[email protected]

3. 5 Page 147 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BRUGG 1. Porcelain Outdoor Termination Type test performed Models are accepted and uploaded as per the
SWITZERLAND in DNV-GL (KEMA)– range of type approval of IEC 62067.
a. Model Name: TE1.245-11 Netherland testing
Contact Person - Mr. Amr Soudi; Size: Up to 2500 mm² laboratory, report WARRANTY:
Regional Sales Manager Drawing Number : S1947-4 #1821-18 & Ten (10) years extended warranty/guarantee in
Phone - +41 79 9135155 Date: 29.03.20 2123-18, respect of defects due to design, manufacture,
Email ID - Prequalification Test installation & workmanship from the date of
[email protected] b. Model Name: TE1.245-12 performed in Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - Size: Up to 2500 mm² DNV-GL (KEMA) – first turnkey project in case of contract award or
[email protected] Drawing Number : S1948-4 Netherland testing date of first delivery in case of direct material
Website - www.bruggcables.com Date: 29.03.2019 laboratory, report supply order.
#1702-19.
c. Model Name: TE1.245-13
Size: Up to 2500 mm²
Drawing Number : S1949-4
Date: 29.03.2019

2. Fluid-Filled GIS Termination


Model Name: TF1.245-11
Size: Up to 2500 mm²
Drawing Number : S1943-4
Date: 16.05.2019

3. Fluid-Filled Transformer Termination


Model Name: TT1.245-11
Size: Up to 2500 mm²
Drawing Number : S1945-4
Date: 29.03.2019

4. Straight Through Joint


Model Name: MPSP 1.245-21
Size: Up to 2500 mm²
Drawing Number : S1329-4
Date: 30.08.2019

5. Cross Bonding Joint


Model Name: MPSP 1.245-31
Size: Up to 2500 mm²
Drawing Number : S1557-4
Date: 09.08.2019

3. 5 Page 148 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN

FUJIKURA
JAPAN

Website - http://www.ffcpg.com.my/

FURUKAWA ELECTRIC CO. LTD.


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

PIRELLI KABEL AND SYSTEM GMBH


GERMANY

Berlin , Germany

3. 5 Page 149 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES & SYSTEMS LTD. PREVIOUSLY LG;


SOUTH KOREA
WARRANTY:
Contact Person - Mr. H.S.JO (General Ten (10) years extended warranty/guarantee in
Manager) Mr. Young Min Seo respect of defects due to design, manufacture,
Email ID - [email protected] installation & workmanship from the date of
Website - http://www.lscable.com/ ? Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

ABB AG
GERMANY

Mannheim, Germany , Brown Boveri


Street 30, 63457 Hannau, Germany

Contact Person - Mr. Josef Hanson


Email ID - [email protected]
Website - http://
http://www.abb.de/cawp/deabb200/ea
b4f33d72c264bec1256fb90037eeaa.as
px

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution 230 kV Tests performed at: WARRANTY:
KOREA, Republic of Co., Ltd. Branch KEMA Ten (10) years extended warranty/guarantee in
P. O. Box 300201, Netherlands respect of defects due to design, manufacture,
Plant -Dangjin Factory Riyadh 11372, Office No. installation & workmanship from the date of
18, Commercial Complex Provisional Acceptance Certificate (PAC) of the
317, Simin Daero, Dongan-gu Building, King Abdulaziz first turnkey project in case of contract award or
Rd. Exit 5, Kingdom of date of first delivery in case of direct material
Anyang-si Saudi Arabia supply order.
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected]
Phone - +82 2 316 9190
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.taihan.com

Total = 10

3. 5 Page 150 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CONDUCTOR FITTINGS
3. 6
Splice & Termination Kits for Power Cable up to 380 KV Applicable Standards: 12-TMSS-10

SUDKABEL Mass Power Contracting PREVIOUSLY ABB.


GERMANY Co.
Unit 2, Building 6429, SÜDKABLE is not allowed to supply unless
Website - http:// Sybawyah Street, successfully performing the required type test
http://www.suedkabel.de/index e.htm Al-Dana District,
Dammam, Saudi Arabia

Mr. Syed Ali Baqar


(Director Business
Development)
+966-13-8462336/
+966-50-6818743
[email protected]

3. 6 Page 151 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BRUGG 1. Porcelain Outdoor sealing end Type test performed WARRANTY:


SWITZERLAND a. Model Name: TE 1.420-02 in DNV-GL (KEMA)– Ten (10) years warranty in respect of defects
Drawing Number: S1718-4 Netherland testing extended warranty/guarantee in respect of
5201 Brugg Switzerland,28 Ch5201 Date: 06.12.2013 laboratory, report defects due to design, manufacture, installation &
Brugg Switzerland, #1821-18 & workmanship from the date of Provisional
b. Model Name: TE 1.420-03 2123-18, Acceptance Certificate (PAC) of the first turnkey
Contact Person - Mr. Amr Soudi; Drawing Number: S1624-4 Prequalification Test project in case of contract award or date of first
Regional Sales Manager Size: Up to 2500 mm2 performed in delivery in case of direct material supply order.
Contact Person Email ID - Creepage Distance: 21000 mm DNV-GL (KEMA) –
[email protected], Netherland testing
[email protected] 2. GIS Wet Type Termination laboratory, report
Website - www.bruggcables.com Model Name: TF 1.420-11 #1702-19.
Drawing Number: S1640-4
Date: 13.11.2013

3. Cross-bonding Joint
Model Name: MPSP 1.420-31
Drawing Number: S1458-4
Date: 10.12.2013

4. Transformer Termination (Wet Type)


Model Name: TT 1.420-11
Drawing Number: S1687-4
Date: 14.11.2013

5. Straight Through Joint


Model Name: MPSP 1.420-21
Drawing Number: S1377-4
Date: 10.12.2013

DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN

3. 6 Page 152 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NKT, GERMANYTEMPELHOFER WEG


39/41
GERMANY

Tempelhofer Weg 39/41, 10829 Berlin ,


Germany

Contact Person - Mr. Mrs. Patricia Wei


Phone - +49 (0)30 60009 -0
Website - http://www.nktcables.com/

VISCAS FUJIKURA
JAPAN

Website - http://
http://www.viscas.com/e contact.html

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

3. 6 Page 153 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NEXANS, COSSONNAY , 380 kV PQ Letter


SWITZERLAND Based on S&SD letter # 14-07330-030504401,
1. GIS Termination (Dry Type) dated 22/10/2014, it is prequalified for 380kV
a. Model Name: DTF 1.380 XLPE Cable Accessories as confirming to
National with the specified designations only.
2. Outdoor Termination
a. Model Name: SOA 1.380 WARRANTY:
Ten (10) years extended warranty/guarantee in
3. Transformer Termination respect of defects due to design, manufacture,
a. Model Name: SFY 1.380 installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
4. Cross Bonding Joint first turnkey project in case of contract award or
a. Model Name: SMP 1.380 date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt:12/02/2013.

PIRELLI
GERMANY

Berlin , Germany

Website - http://
http://www.pirelli.com/splash/index.htm
l

3. 6 Page 154 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS CABLES & SYSTEMS LTD. 380 kV cable Tests performed at PREVIOUSLY LG;
SOUTH KOREA 1. Outdoor Termination KEMA
1x2500 mm2, CU/XLPE/LEAD/PE Netherlands (Aug,
Contact Person - Mr. H.S.JO (General a. Model Name: UEMA40Q004, 2014 to PQ Letter
Manager) Mr. Young Min Seo b. Model Name: UMEMA40Q004 from Dec, 2014) Based on S&SD letter # 15-3193-30504401 dated
Email ID - [email protected] PPC insulators (Germany). Test Report Nos. May 03, 2015, the manufacturer is prequalified to
Website - http://www.lscable.com/ ? 1066-14 & TIC supply the Power Cables & Accessories with the
2. Transformer Termination 1564-14 specified designations only:
a. Model Name: WC-114022 with
Drawing # WC-114022 rev. 00 Tests performed at WARRANTY:
KEMA , Netherlands Ten (10) years extended warranty/guarantee in
3. GIS Termination (Dry Type) (5th of July to 1st of respect of defects due to design, manufacture,
a. Model Name: UEPG40Q001 with Dec, 2021) Test installation & workmanship from the date of
Drawing # UEPG40Q001 rev. 00 Report No. 1603-21. Provisional Acceptance Certificate (PAC) of the
b. Model Name: UEPG40Q003 with first turnkey project in case of contract award or
Drawing Number: UEPG40Q003 date of first delivery in case of direct material
supply order.
4. Cross Bonding Joint
a. Model Name: UEMK40Q002 with Based on S&SD letter #22-00873-30504401
Drawing # UEMK40Q002 rev. 00 dated July 21, 2022, the manufacturer is
prequalified for Splice & Termination Kits for
Note: For all future SEC/National Grid Power Cable up to 380 KV as confirming to
SA projects/direct purchase orders, National Grid SA specification # 12-TMSS-10,
porcelain bushings for outdoor with the following conditions:
terminations shall be procured from our
approved list. WARRANTY

Ten (10) years extended warranty from the date


of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter #LSC-SAU-WC-20210609
dated June 09, 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

3. 6 Page 155 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution 380 kV Tests performed at: PQ Letter
KOREA, Republic of Co., Ltd. Branch 1x2500mm2 KEMA Based on S&SD letter # 14-08139-01-30504401
P. O. Box 300201, Netherlands (Jan. dt: January 07, 2015, the manufacturer is
Plant -Dangjin Factory Riyadh 11372, Office No. 1. Outdoor Termination 2014 to prequalified to supply power cables &
18, Commercial Complex a. Model Name: May, 2014) accessories with the specified designations only:
317, Simin Daero, Dongan-gu Building, King Abdulaziz CVC-APS-3804605N-BD rev. A Report # TIC
Rd. Exit 5, Kingdom of 3094-14 WARRANTY:
Anyang-si Saudi Arabia 2. GIS termination (Fluid-Filled ) Ten (10) years extended warranty in respect of
+966 11 410 1773 a. Model Name: CVC-GWO-380-BD rev. the defects due to design, manufacturing,
Contact Person - Jang Hee Lee [email protected] A installation and workmanship from the date of the
Phone - +82 2 316 9190 Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] 3. GIS termination (Dry Type) first turnkey project (in case of contract award)
Contact Person Email ID - a. Model Name: CVC-GWBS-380-BD or from the date of first delivery in case of direct
[email protected] rev. A material supply order shall be provided as
Website - www.taihan.com confirmed by the manufacturer through their
4. Transformer Termination letter # Nil dated September 02, 2014.
a. Model Name: CVC-OWO-380-BD
with Drawing # WD-433884 rev. 01

5. Cross Bonding Joint


a. Model Name: CVC-MIP-380-BD rev.
A

6. Cross Bonding Joint (Type A)


a. Model Name: CVC-MIP-380-R1-BD
rev. A

7. Straight Through Joint


a. Model Name: CVC-MNP-380-BD rev.
A

3. 6 Page 156 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ILJIN ELECTRIC CO. LTD. Dopa Co. for Trading and 380kV Based on S&SD letter# 16-2299-02-30504401
SOUTH KOREA industry 1. Outdoor Termination: dated May 02, 2016, it is prequalified for380kV
Al Nuzha District Riyadh, a. Model Name : APS(CE-W) 420-S, Accessories [Outdoor Termination-Porcelain Type
Plant -South KOREA Saudi Arabia P.O. Box with Drawing # : APS(CE-W)420-S rev. APS(CE-W) 420-S, Outdoor Termination-Porcelain
87017 Code No. 11462 1 Type APWA(CE-W) 420-S, Dry Type GIS
905-64, Mannyeon-ro, Hwaseong-si, Mr. Abdullah Alabdullah b. Model Name : APWA(CE-W) 420-S, Termination GDEO(CE-W) 420S, Premold
Gyeonggi-do Email / with Drawing # : APWA (CE-W) 420-S Insulation Joint Type MIDFD(CE-W) 420-S,
alabdullah@dopacompan rev. 1 Premold Straight Joint Type MNDFD(CE-W) 420-S]
Contact Person - Mr. Tony Lim, Mr. y.com 2. GIS Termination (Dry Type ) with the following conditions:
Daniel Park TEL / (+966) 11 2694609 a. Model Name : GDEO(CE-W) 420S,
Phone - +82-2-707-9253 , Mobile / (+966) with Drawing # : GDEO(CE-W)420-S • Ten (10) years extended warranty from the
Email ID - [email protected]; 504122831 rev. 1 date of PAC of the turnkey project in case of
[email protected] 3. Cross Bonding Joint: contract award and date of delivery in case of
a. Model Name: MIDFD(CE-W)420-S, direct material supply order, as confirmed by the
with Drawing #: MIDFD(CE-W)420-S manufacturer through letter # ILJHC-160412 A
rev. 0 dated 12/04/2016.
4. Straight Through Joint:
a. Model Name: MNDFD(CE-W) 420-S,
with Drawing #: MNDFD(CE-W)420-S
rev. 0

Total = 11

CONDUCTOR FITTINGS
3. 7
LINK BOXES FOR GROUNDING OF U/G POWER CABLE Applicable Standards: 12-TMSS-11

LS CABLES PREVIOUSLY LG
SOUTH KOREA

Plant -Gumi/Korea

13 F Ls Tower ,127, Ls-Ro,


Dongan-Gu, Anyang-Si, Gyeonggi-Do,
Korea

Contact Person - Jiyup Baik


Phone - +82-544697602
Email ID - [email protected]
Website - http://www.lscns.com

3. 7 Page 157 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DEMIRER KABLO
TURKEY

Demirer Kablo, Tesisleri San. Ve Tic


A.S. 4 Eylul Mahallesi Ismet Inonu
Caddesi No. 279 Bozuyuk/ Bilecik-
Turkey

Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

PIRELLI
GERMANY

Berlin , Germany

Website - http://
http://www.pirelli.com/splash/index.htm
l

FUJIKURA VISCAS CORP


JAPAN

Website - http://www.ffcpg.com.my/

3. 7 Page 158 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AARTCO UP TO 230KV.
Saudi Arabia

Al-Khobar , Saudi Arabia

Website - http://www.aartco.com.sa/

Insulect Australia PTE- Power Previously HAYCOLEC SWITCHGEAR PTY –


AUSTRALIA Transmission and Australia-NSW [The name has been changed to
Telecommunication AK POWER SOLUTONS PTY LTD-
Huntingwood, Nsw , Australia Equipment Co Australia-Huntingwood, NSW based on
8131 Modon 3 Jeddah S&SD/P&SFD letter # 13-07444-30504401 dated
Industrial City Plot No 25: December 11, 2013 and based on AK POWER
P.O Box 8234 Jeddah SOLUTONS PTY LTD-
22772-2478 Australia-NSW-Huntingwood Letter # NG251113
Tel: +966 1260 95165: dated November 25, 2013]
Cell Ph: +966 595 33 23
74
[email protected] ,
[email protected]

Abdullah Mohammed Hassan


Al-Shahrani Factory
Saudi Arabia

Plant -Riyadh

P.O. Box 86820 Near Ice Cone Zone


183 Riyadh Saudi Arabia.

Contact Person - Mr. MOHAMMAD


ABDUL SAMAD , Operation and Sales
Phone - 00966 11 2653414
Email ID - [email protected];
[email protected]

3. 7 Page 159 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EM ELEKTRIK MALZERMELERI Gulf Trade Link Est. Type tests were PQ Letter
YUKLENIM SAN.TIC. A.S. PO Box 20362 Riyadh conducted in KEMA Based on S&SD letter # 15-07259-2-30504401 dt:
TURKEY 11455 Netherland in Sept17, 2015, the manufacturer is prequalified to
Mr. Ahmed Qazi presence of supply Link box, Up to 132kV with Stainless Steel
(Itosb)No:25 34959 Tepeören-Tuzla Commercial Manager SEC/National Grid Material as conforming to National Grid SA
Istanbul / Turkey [email protected] SA Engineers during specification # 12-TMSS-11
1st to 5th June
Phone - +90 216 593 37 15 & 2015.This Test was WARRANTY:
19(Pbx),Fax: +90 216 593 37 21 repeated on this link Ten (10) years extended warranty in respect of
Email ID - [email protected] box during 30th the defects due to design, manufacturing,
June and 1st July installation and workmanship from the date of the
2015 in DNV-GL . Provisional Acceptance Certificate (PAC) of the
Type Test Report No. project (in case of contract award) and from the
1206-15 VI, 1207-15 date of delivery in case of direct material supply
VI, 1208-15 VI, order shall be provided as confirmed by the
1209-15 VI manufacturer through their extended warranty
letter attached with the letter #EM-011-/031 dated
January 25, 2012.

Advanced Technical Solutions Previously " MOHAMMAD AL –OJAIMI FACTORY


Company for Industry (MATCO) ", the name has been changed to Advanced
Saudi Arabia Technical Solutions Company for Industry
(MATCO)
Plant -Riyadh , Saudi Arabia
PAD MOUNTED STAINLESS STEEL BOXES AND
Website - http://www.alojaimi.com/Our UNDER GROUND FIBER GLASS BOXES UP TO
Companies/Introduction - Mohammed 132KV ACCEPTABLE.
Al-Oja/introduction - mohammed
al-oja.html WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

3. 7 Page 160 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

POWER TRANSMISSION AND PQ Letter


TELECOMMUNICATION EQUIPMENTS Based on TS&SD fax ref# 09-00396-1-03032301,
FACTORY (P.T.E. CO.) (CEPCO) dt: 17/02/2009 P.T.E is prequalified for Link Boxes
Saudi Arabia rated up to 380kV.

Jeddah Industrial City : P.O Box 8234 WARRANTY:


Jeddah 21482 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Plant: Plot No. 1&2, Al-Mahjar Street, installation & workmanship from the date of
Industrial Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Contact Person - Eng. Mohammad date of first delivery in case of direct material
Saleem Mir (General Manager); Mr. supply order as confirmed by the manufacturer
Faisal Jandali through their letter no.CEP/SCECO/L/019, dt: 11th
Phone - +966 1260 95165; +966 595 June, 2007.
3323 74; +966126608629;
+966504661072
Email ID - [email protected]
Website - www.pte-sa.com

STEINER
GERMANY

Website -
http://www.steiner-binoculars.com/ind
ex.html

ABB-Ludvika
SWEDEN

Plant -Sweden

Ludvika, Sweden

Contact Person - Mr. Magnus


Johansson
Phone - +46 240 783228
Email ID -
[email protected]
Website - http://www.abb.se/

Total = 13

3. 7 Page 161 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CONDUCTOR FITTINGS
3. 8
Splice and Termination for Medium Voltage Power Cables Applicable Standards: 12-TMSS-04

3. 8 Page 162 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Prysmian Indoor termination Type Tests PQ Letter


FRANCE 13.8kV, Model: CDTO-1C-15-Nd-T3 A~I successfully Based on S&SD letter #21-00793-01-30504401
(Drawing No. 42116, Rev. A) completed at CABLE dated August 02, 2021, the manufacturer is
Plant -Cornimont Plant 13.8kV, Model: CDTO-3C-15-Nd-T3 A~I TECHNOLOGY prequalified for Splice and Termination for Medium
(Drawing No. 42116, Rev. A) LABORATORIES - Voltage Power Cables as confirming to National
Cornimont Plant, Z.I. Le Plein de Report# 14-103a Grid SA specification # 12-TMSS-04, with the
Xoulces; 88 310 Cornimont Outdoor termination (Inland area) dated following conditions:
13.8kV, Model: CDTO-1C-15-Nd-T3 A~I 28-October-2014.
Cornimont (Drawing No. 42116, Rev. A) for the following WARRANTY
13.8kV, Model: CDTO-3C-15-Nd-T3 A~I termination: Ten (10) years extended warranty from the date
Contact Person - Victor Romera (Drawing No. 42116, Rev. A) -Model: of PAC of the first turnkey project (in case of
Contact Person Email ID - 33kV, Model: CDTO-1C-35-Nd-T3 E~I CDTO-1C-15-Nd-T3 contract award) or date of first delivery (in case
[email protected] (Drawing No. 42118, Rev. A) A~I (Drawing No. of direct material supply order), as confirmed,
Website - www.prysmiangroup.com 33kV, Model: CDTO-3C-35-Nd-T3 E~I 42116, Rev. A) , through their Letter #Nil dated 22 March 2024,
(Drawing No. 42118, Rev. A) -Model: shall be applicable for the equipment to be
CDTO-3C-15-Nd-T3 supplied to SEC/National Grid SA.
Outdoor termination (Coastal area) A~I (Drawing No.
13.8kV, Model: CDTO-1C-15-Ne-T3 A~I 42116, Rev. A)
(Drawing No. 42117, Rev. A) -Model: *EC: Multi-section mechanical conductor contact
13.8kV, Model: CDTO-3C-15-Ne-T3 A~I CDTO-1C-15-Ne-T3 *T2: Copper tapes metallic screen cable
(Drawing No. 42117, Rev. A) A~I (Drawing No. *T3: Copper wires metallic screen cable
33kV, Model: CDTO-1C-35-Ne-T3 E~I 42117, Rev. A) *AR: Armored cable
(Drawing No. 42119, Rev. A) -Model: *A/C: Aluminium or Copper conductor cable
33kV, Model: CDTO-3C-35-Ne-T3 E~I CDTO-3C-15-Ne-T3 *rA~rH: Adapter size linked to cable diameter
(Drawing No. 42119, Rev. A) A~I (Drawing No. over insulation
42117, Rev. A) *nC~nF: Adapter size linked to cable diameter
Elbow Separable Connectors - over insulation
Interface A / 250A
Drawing No: N42264 Type Tests
Models: successfully
Unarmored Cables completed at
11 kV and 13.8kV: Prysmian Lab -
MSCE/EC-250-A-24-T2/T3-25/95 Report#
11 kV and 13.8kV: RQ-R&D-ELAB-ET-1
MSCE/EC-250-A-17-T2/T3-25/95 5-156 dated
11 kV: 29-April-2016. for
MSCE/EC-250-A-12-T2/T3-25/95 the following
Armored Cables termination:
11 kV and 13.8kV: -Model:
MSCE/EC-250-A-24-T2/T3-AR-25/95 CDTO-1C-35-Nd-T3
11 kV and 13.8kV: E~I (Drawing No.
MSCE/EC-250-A-17-T2/T3-AR-25/95 42118, Rev. A)

3. 8 Page 163 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

11 kV: -Model:
MSCE/EC-250-A-12-T2/T3-AR-25/95 CDTO-3C-35-Nd-T3
Remark: Approved model up to size 95 E~I (Drawing No.
mm² only. To supply model on size 42118, Rev. A)
more than 95 mm², it shall be type -Model:
tested with the 1st project CDTO-1C-35-Ne-T3
E~I (Drawing No.
Straight Separable Connectors – 42119, Rev. A)
Interface / A250A -Model:
Drawing No: N42265 CDTO-3C-35-Ne-T3
Models: E~I (Drawing No.
Unarmored Cables 42119, Rev. A)
11 kV and 13.8kV:
MSCS/EC-250-A-24-T2/T3-25/95 Type Tests
11 kV and 13.8kV: successfully
MSCS/EC-250-A-17-T2/T3-25/95 completed at IPH
11 kV: Berlin ,Type Test
MSCS/EC-250-A-12-T2/T3-25/95 reports No. :
Armored Cables -
11 kV and 13.8kV: 2636.2090171.0649
MSCS/EC-250-A-24-T2/T3-AR-25/95 (2009)
11 kV and 13.8kV: -
MSCS/EC-250-A-17-T2/T3-AR-25/95 2636.2090170.1078
11 kV: (2010)
MSCS/EC-250-A-12-T2/T3-AR-25/95 - 2636.2080549.936
Remark: Approved model up to size 95 (2008)
mm² only. To supply model on size -
more than 95 mm², it shall be type 2636.2090173.0912
tested with the 1st project (2009)
- 2636.2080549.937
Elbow Separable Connectors - (2009)
Interface B / 400A
Drawing No: N42266
Models:
Unarmored Cables
33kV:
MSCE/EC-400-B-36-rE-T2/T3-95/240
11 kV and 13.8kV:
MSCE/EC-400-B-24-rB-T2/T3-95/150
11 kV and 13.8kV:
MSCE/EC-400-B-24-rC-T2/T3-95/240
11 kV and 13.8kV:

3. 8 Page 164 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MSCE/EC-400-B-24-rD-T2/T3-95/240
11 kV and 13.8kV:
MSCE/EC-400-B-17-rC-T2/T3-95/240
11 kV:
MSCE/EC-400-B-12-rB-T2/T3-95/240
Armored Cables
33kV: MSCE/EC-400-B-36-rE-T2/T3-AR
-95/240
11 kV and 13.8kV:
MSCE/EC-400-B-24-rB-T2/T3-AR
-95/150
11 kV and 13.8kV:
MSCE/EC-400-B-24-rC-T2/T3-AR-95/24
0
11 kV and 13.8kV:
MSCE/EC-400-B-24-rD-T2/T3-AR-95/24
0
11 kV and 13.8kV:
MSCE/EC-400-B-17-rC-T2/T3-AR-95/24
0
11 kV:
MSCE/EC-400-B-12-rB-T2/T3-AR-95/24
0
Remark: Approved model are 95 to 240
mm² only. To supply model on size
more than 240 mm² OR less than 95
mm² , it shall be type tested with the
1st project

Tee Separable Connectors - Interface


C /630A (Symmetric)
Drawing No: 42268
Models:
Unarmored Cables
33kV:
MSCT/EC-630-C-36-rF-T2/T3-150/300
33kV:
MSCT/EC-630-C-36-rE-T2/T3-95/240
11 kV and 13.8kV:
MSCT/EC-630-C-24-rB-T2/T3-95/150
11 kV and 13.8kV:
MSCT/EC-630-C-24-rC-T2/T3-95/240

3. 8 Page 165 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

11 kV and 13.8kV:
MSCT/EC-630-C-24-rD-T2/T3-95/240
11 kV and 13.8kV:
MSCT/EC-630-C-24-rE-T2/T3-185/300
11 kV and 13.8kV:
MSCT/EC-630-C-17-rC-T2/T3-95/240
11 kV and 13.8kV:
MSCT/EC-630-C-17-rE-T2/T3-185/300
11 kV:
MSCT/EC-630-C-12-rB-T2/T3-95/240
11 kV:
MSCT/EC-630-C-12-rD-T2/T3-185/300
Armored Cables
33kV:
MSCT/EC-630-C-36-rF-T2/T3-AR-150/3
00
33kV:
MSCT/EC-630-C-36-rE-T2/T3-AR-95/24
0
11 kV and 13.8kV:
MSCT/EC-630-C-24-rB-T2/T3-AR-95/15
0
11 kV and 13.8kV:
MSCT/EC-630-C-24-rC-T2/T3-AR-95/24
0
11 kV and 13.8kV:
MSCT/EC-630-C-24-rD-T2/T3-AR-95/24
0
11 kV and 13.8kV:
MSCT/EC-630-C-24-rE-T2/T3-AR-185/3
00
11 kV and 13.8kV:
MSCT/EC-630-C-17-rC-T2/T3-AR-95/24
0
11 kV and 13.8kV:
MSCT/EC-630-C-17-rE-T2/T3-AR-185/3
00
11 kV:
MSCT/EC-630-C-12-rB-T2/T3-AR-95/24
0
11 kV:
MSCT/EC-630-C-12-rD-T2/T3-AR-185/3

3. 8 Page 166 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

00
Remark: Approved model are 95 to 300
mm² only. To supply model on size
more than 300 mm² OR less than 95
mm² , it shall be type tested with the
1st project

Tee Separable Connectors - Interface


C / 630A (Asymmetric)
Drawing No: N42270
Models:
Unarmored Cables
33kV:
MSCEA/EC-630-C-36-rF-T2/T3-150/300
33kV:
MSCEA/EC-630-C-36-rE-T2/T3-95/240
11 kV and 13.8kV:
MSCEA/EC-630-C-24-rB-T2/T3-95/150
11 kV and 13.8kV:
MSCEA/EC-630-C-24-rC-T2/T3-95/240
11 kV and 13.8kV:
MSCEA/EC-630-C-24-rD-T2/T3-95/240
11 kV and 13.8kV:
MSCEA/EC-630-C-24-rE-T2/T3-185/300
11 kV and 13.8kV:
MSCEA/EC-630-C-17-rC-T2/T3-95/240
11 kV and 13.8kV:
MSCEA/EC-630-C-17-rE-T2/T3-185/300
11 kV:
MSCEA/EC-630-C-12-rB-T2/T3-95/240
11 kV:
MSCEA/EC-630-C-12-rD-T2/T3-185/300
Armored Cables
33kV:
MSCEA/EC-630-C-36-rF-T2/T3-AR-150/
300
33kV:
MSCEA/EC-630-C-36-rE-T2/T3-AR-95/2
40
11 kV and 13.8kV:
MSCEA/EC-630-C-24-rB-T2/T3-AR-95/
150

3. 8 Page 167 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

11 kV and 13.8kV:
MSCEA/EC-630-C-24-rC-T2/T3-AR-95/
240
11 kV and 13.8kV:
MSCEA/EC-630-C-24-rD-T2/T3-AR-95/
240
11 kV and 13.8kV:
MSCEA/EC-630-C-24-rE-T2/T3-AR-185/
300
11 kV and 13.8kV:
MSCEA/EC-630-C-17-rC-T2/T3-AR-95/
240
11 kV and 13.8kV:
MSCEA/EC-630-C-17-rE-T2/T3-AR-185/
300
11 kV:
MSCEA/EC-630-C-12-rB-T2/T3-AR-95/
240
11 kV:
MSCEA/EC-630-C-12-rD-T2/T3-AR-185
/300
Remark: Approved model are 95 to 300
mm² only. To supply model on size
more than 300 mm² OR less than 95
mm² , it shall be type tested with the
1st project

3. 8 Page 168 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Nexan Nexan Heat shrinkable Termination 1.a Tests performed PQ Letter


ITALY +390292910211 1. Indoor Termination at University of
a. Model Name: 17TTGI1/17TTGI3 Karlsruhe (Jan, Based on S&SD letters # 20-01254-30504401
Plant -Italy Drawing No. : 17TTGI1…/ 17TTGI3… 2014) Test Report dated August 27, 2020, the manufacturer is
Date: 10.9.18 Nos. 2014-02 prequalified for SPLICE & TERMINATIONS FOR MV
Offida, Italy Voltage Rating: 13.8 kV POWER CABLES as confirming to National Grid
Size : 50 Up to 1000 mm2 (CU) 1.b Tests performed SA specification # 12-TMSS-04, with the
Offida 70 Up to 300 mm2 (AL) at Euromold France following conditions:
(July, 2014 to Sep,
Contact Person - Mohammed Nabeel b. Model Name: 36TTGI1/ 36TTGI3 2014) Test Report WARRANTY
Phone - +966549452401 Drawing No. : 36TTGI1…/ 36TTGI3… Nos. TE 413 14 18
Email ID - Date: 10.9.18 Five (5) years extended warranty from the date
[email protected] Voltage Rating: 33 kV 1.c Tests performed of first delivery under direct material supply
Contact Person Email ID - Size : 70 Up to 1000 mm2 (CU) at KEMA – order, as confirmed, through their Letter No. Nil
[email protected] 50 Up to 500 mm2 (AL) Netherland dated Nil shall be applicable for the equipment to
Website - nexan.com (Feb.,2015 to be supplied to SEC/National Grid SA.
c. Model Name: 24MONOi1/ 24MONOi3 October 2015) Test
Drawing No. : DVA1405/ DVA1407 Report Nos. 1321-15 Remarks:
Date: 24.03.2020 1. c. Approved for models up to size 300 mm². To
Voltage Rating: 13.8 kV 1.d Tests performed supply these approved models on sizes more
Size : 50 Up to 1000 mm2 (CU) at RWE Euro test than 300 mm², it shall be type tested with the 1st
70 Up to 300 mm2 (AL) Lab. – Germany project
(March 2015 to Sep. 1. d. Approved for models up to size 300 mm². To
d. Model Name: 36MONOi1/ 36MONOi3 2015) Test Report supply these approved models on sizes more
Drawing No. : DVA1405/ DVA1407 Nos. 14-379-2 than 300 mm², it shall be type tested with the 1st
Date: 24.03.2020 Version:2/2 project
Voltage Rating: 33 kV 1. e. Approved for models up to size 300 mm². To
Size : 70 Up to 1000 mm2 (CU) 1.e Tests performed supply these approved models on sizes more
50 Up to 500 mm2 (AL) at IPH – Germany than 300 mm², it shall be type tested with the 1st
(Nov., 2017 to Sep. project
e. Model Name: 42MONOi1 2018) Test Report 2. c. Approved for models up to size 300 mm². To
Drawing No. : DVA1405 Nos. 07319-18-0708 supply these approved models on sizes more
Date: 24.03.2020 than 300 mm², it shall be type tested with the 1st
Voltage Rating: 33 kV 2.a Tests performed project
Size : 70 Up to 1000 mm2 (CU) at University of 2. d. Approved for models up to size 300 mm². To
50 Up to 500 mm2 (AL) Karlsruhe (Jan, supply these approved models on sizes more
2014) Test Report than 300 mm², it shall be type tested with the 1st
F. Model Name: 24TTGI1 (for 1-Core) Nos. 2014-02 project
Date: 20.01.2014 2. e. Approved model subject to Type Test for 1st
Voltage Rating: 24 kV 2.b Tests performed Project.
Size : max 630 mm² at KEMA –
Netherland (Jan.,

3. 8 Page 169 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

G. Model Name: 24TTGI3 (for 3-Cores) 2015 to Nov. 2015)


Date: 10.09.18 Test Report Nos.
Voltage Rating: 24 kV 1500-15
Size : max 300 mm²
2.c Tests performed
2. Outdoor Termination at KEMA –
a. Model Name: 17TTGE1/17TTGE3 Netherland
Drawing No. : 17TTGE1…/ 17TTGE3… (Feb.,2015 to
Date: 10.9.18 October 2015) Test
Voltage Rating: 13.8 kV Report Nos. 1320-15
Size : 50 Up to 1000 mm2 (CU)
70 Up to 300 mm2 (AL) 2.d Tests performed
at IPH – Germany
b. Model Name: 36TTGE1/ 36TTGE3 (Nov., 2017 to Sep.
Drawing No. : 36TTGE1…/ 36TTGE3… 2018) Test Report
Date: 10.9.18 Nos. 07319-
Voltage Rating: 33 kV 18-0755
Size : 70 Up to 1000 mm2 (CU)
50 Up to 500 mm2 (AL)

c. Model Name: 24MONOe1/


24MONOe3
Drawing No. : DVA1406/ DVA1408
Date: 24.03.2020
Voltage Rating: 13.8 kV
Size : 50 Up to 1000 mm2 (CU)
70 Up to 300 mm2 (AL)

d. Model Name: 36MONOe1/


36MONOe3
Drawing No. : DVA1406/ DVA1408
Date: 24.03.2020
Voltage Rating: 33 kV
Size : 70 Up to 1000 mm2 (CU)
50 Up to 500 mm2 (AL)

e. Model Name: 42MONOe1


Drawing No. : DVA1406
Date: 24.03.2020
Voltage Rating: 33 kV
Size : 70 Up to 1000 mm2 (CU)
50 Up to 500 mm2 (AL)

3. 8 Page 170 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

F. Model Name: 24TTGE1 (for 1-Core)


Date: 20.01.2014
Voltage Rating: 24 kV
Size : max 630 mm²

G. Model Name: 24TTGE3 (for 3-Cores)


Date: 10.09.18
Voltage Rating: 24 kV
Size : max 300 mm²

Nexan Nexan Premolded Termination 1.a Tests performed PQ Letter


BELGIUM +390292910211 1. Indoor Termination at Elab (June, 2016
a. Model Name: AIN20 to July 2016) Test Based on S&SD letters # 20-01254-30504401
Plant -Belgium Drawing No. : SD 859/E Rev.0 Report Nos. TE 113 dated August 27, 2020, the manufacturer is
Date: July 2017 16 03 prequalified for SPLICE & TERMINATIONS FOR MV
Divisie Euromold Zuid III Industrielaan Voltage Rating: 13.8 kV 1.b Tests performed POWER CABLES as confirming to National Grid
12, 9320 Erembodegem, Belgium Size : 50 Up to 1000 mm2 (CU) at Elab (Jan., 2012 SA specification # 12-TMSS-04, with the
70 Up to 300 mm2 (AL) to Feb. 2012) Test following conditions:
Erembodegem Report Nos. TE 113
b. Model Name: AIN30 11 04 WARRANTY
Contact Person - Mohammed Nabeel Drawing No. : SD 859/E Rev.0 2.a Tests performed
Phone - +966549452401 Date: July 2017 at Elab (Jan., 2012 Five (5) years extended warranty from the date
Email ID - Voltage Rating: 33 kV to Feb. 2012) Test of first delivery under direct material supply order
[email protected] Size : 70 Up to 1000 mm2 (CU) Report Nos. TE 113 as confirmed, through their Letter No. Nil dated Nil
Contact Person Email ID - 50 Up to 500 mm2 (AL) 11 04 shall be applicable for the equipment to be
[email protected] 2.b Tests performed supplied to SEC/National Grid SA.
Website - nexan.com 2. Outdoor Termination at Elab (Jan., 2012
a. Model Name: AFN20 to Feb. 2012) Test
Drawing No. : SD 741/E Rev.0 Report Nos. TE 113
Date: September 2012 11 04
Voltage Rating: 13.8 kV
Size : 50 Up to 1000 mm2 (CU)
70 Up to 300 mm2 (AL)

b. Model Name: AFN30


Drawing No. : SD 741/E Rev.0
Date: September 2012
Voltage Rating: 33 kV
Size : 70 Up to 1000 mm2 (CU)
50 Up to 500 mm2 (AL)

3. 8 Page 171 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Nexan Nexan Cold shrinkable Termination 1.a Tests performed PQ Letter


FRANCE +390292910211 1. Indoor Termination at Euromold France
a. Model Name: ITK224 (Nov, 2000 to Apr, Based on S&SD letters # 20-01254-30504401
Plant -France Drawing No. : ITK 2001) Test Report dated August 27, 2020, the manufacturer is
Date: 05/2017 Nos. TE 113 00 17 prequalified for SPLICE & TERMINATIONS FOR MV
ZI DE 08350, Donchery, France Voltage Rating: 13.8 kV 1.b Tests performed POWER CABLES as confirming to National Grid
Size : 50 Up to 300 mm2 (CU) at Euromold France SA specification # 12-TMSS-04, with the
Donchery 70 Up to 300 mm2 (AL) (Feb, 2003) Test following conditions:
Report Nos. TE 113
Contact Person - Mohammed Nabeel b. Model Name: ITK324 03 02 WARRANTY
Phone - +966549452401 Drawing No. : ITK 2.a Tests performed
Email ID - Date: 05/2017 at Euromold France Five (5) years extended warranty from the date
[email protected] Voltage Rating: 13.8 kV (Nov, 2000 to Apr, of first delivery under direct material supply
Contact Person Email ID - Size : 50 Up to 630 mm2 (CU) 2001) Test Report order, as confirmed, through their Letter No. Nil
[email protected] 70 Up to 300 mm2 (AL) Nos. TE 113 00 18 dated 27/03/2019 shall be applicable for the
Website - nexan.com 2.b Tests performed equipment to be supplied to SEC/National Grid SA.
2. Outdoor Termination at Euromold France
a. Model Name: OTK224 (Feb, 2003) Test Remarks
Drawing No. : OTK Report Nos. TE 113 1.b. Approved for models up to size 400 mm². To
Date: 05/2017 03 01 supply these approved models on sizes more
Voltage Rating: 13.8 kV than 400 mm², it shall be type tested with the 1st
Size : 50 Up to 300 mm2 (CU) project.
70 Up to 300 mm2 (AL)
2.b. Approved for models up to size 400 mm². To
b. Model Name: OTK324 supply these approved models on sizes more
Drawing No. : OTK than 400 mm², it shall be type tested with the 1st
Date: 05/2017 project.
Voltage Rating: 13.8 kV
Size : 50 Up to 630 mm2 (CU)
70 Up to 300 mm2 (AL)

3. 8 Page 172 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sudkable Sudkable Premolded Termination 1.a Tests performed PQ Letter


GERMANY +966506818743 1. Indoor Termination at University of
a. Model Name: SEI24 Karlsruhe (May, Based on S&SD letters # 20-01253-30504401
Plant -Mannheim, Germany Drawing No. : 100.17.52 1998) Test Report dated August 27, 2020, the manufacturer is
Rev.6 Nos. 2001-69/1 prequalified for SPLICE & TERMINATIONS FOR MV
Rhenaniastrasse 12 - 30 | 68199 Voltage Rating: 13.8 kV 1.b Tests performed POWER CABLES as confirming to National Grid
Mannheim | Germany Size : 50 Up to 300 mm2 (CU) at ABB Energie SA specification # 12-TMSS-04, with the
70 Up to 300 mm2 (AL) Kabel GmbH following conditions:
Mannheim (27.05.98) Test
b. Model Name: SEHDI 20.2 Report No. GAX-NE WARRANTY
Contact Person - Ali Baqar, Syed Drawing No. : 100.17.51 1.c Tests performed
Phone - +49 621 8507 01 Rev.4 at University of Five (5) years extended warranty from the date
Email ID - [email protected] Voltage Rating: 13.8 kV Karlsruhe (April, of PAC of the project (in case of contract award)
Contact Person Email ID - Size : 400 Up to 630 mm2 (CU) 1997) Test Report or max 5.5 years after delivery, whichever
[email protected] Nos. 97014/E occurs first, as confirmed, through their Letter
Website - suedkabel.de c. Model Name: SEHDI 30.1 2.a Tests performed No. Nil dated 16/09/2019 shall be applicable for
Drawing No. : 100.19.50 at University of the equipment to be supplied to SEC/National Grid
Rev.1 Karlsruhe (Dec, SA.
Voltage Rating: 33 kV 2001) Test Report
Size : 70 Up to 630 mm2 (CU) Nos. 2001-70 Remarks
50 Up to 500 mm2 (AL) 2.b Tests performed 1.b. Approved model subject to Type Test for 1st
at ABB lab (Feb. Project as discussed and agreed.
2. Outdoor Termination 1991) Test Report 1.c. Approved for models up to size 300 mm². To
a. Model Name: SEF24 Nos. 1/G 281 f supply these approved models on sizes more
Drawing No. : 100.18.83 2.c Tests performed than 300 mm², it shall be type tested with the 1st
Rev.6 at FGH Lab. (Aug. project.
Voltage Rating: 13.8 kV 1993) Test Report 2.b. Approved for models up to size 300 mm². To
Size : 120 Up to 300 mm2 (CU) Nos. HV 930 113 11 supply these approved models on sizes more
185 Up to 300 mm2 (AL) 04 than 300 mm², it shall be type tested with the 1st
3.a Tests performed project.
b. Model Name: SEHDF 20.2 at ABB lab (Jan. 2.c. Approved for models up to size 300 mm². To
Drawing No. : 100.18.81 2007) Test Report supply these approved models on sizes more
Rev.5 Nos. 33/S 245 than 300 mm², it shall be type tested with the 1st
Voltage Rating: 13.8 kV 4.a Tests performed project.
Size : 50 mm2 (CU) at University of 4.b. Approved model subject to Type Test for 1st
400 Up to 630 mm2 (CU) Karlsruhe (June Project as discussed and agreed
2003) Test Report 5.c. Approved for models up to size 400 mm². To
c. Model Name: SEHDF 30.1 Nos. 2003-51 supply these approved models on sizes more
Drawing No. : 100.19.46 4.b Tests performed than 400 mm², it shall be type tested with the 1st
Rev.3 at Sudkabel GmbH project.
Voltage Rating: 33 kV (April 4, 2012~June 5.f. Approved for models up to size 400 mm². To
Size : 70 Up to 630 mm2 (CU) 6,2012) Test Report supply these approved models on sizes more

3. 8 Page 173 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

50 Up to 500 mm2 (AL) No. 02/G276 than 400 mm², it shall be type tested with the 1st
5.a Tests performed project.
3. Straight Plug Termination at University of
a. Model Name: SEHDG23 Karlsruhe (May
Drawing No. : 100.310.32 1996) Test Report
Rev.1 Nos. 96035
Voltage Rating: 13.8 kV 5.b Tests performed
Size : 50 Up to 185 mm2 (CU) at University of
70 Up to 240 mm2 (AL) Karlsruhe (Sep.
2010) Test Report
4. Elbow Plug Termination Nos. 2010-27
a. Model Name: SEW24 5.c Tests performed
Drawing No. : 100.310.126 at University of
Rev.6 Karlsruhe (July
Voltage Rating: 13.8 kV 2003) Test Report
Size : 50 mm2 (CU) Nos. 2003-52
70 mm2 (AL) 5.d Tests performed
at University of
b. Model Name: SEHDW21 Karlsruhe (May
Drawing No. : 100.310.25 1996) Test Report
Rev.4 Nos. 96035
Voltage Rating: 13.8 kV 5.e Tests performed
Size : 120 mm2 (CU) at University of
Karlsruhe (Sep.
5. Inner Cone Plug Termination 2010) Test Report
a. Model Name: SEIK23 Nos. 2010-27
Drawing No. : 100.310.71 5.f Tests performed
Rev.15 at University of
Voltage Rating: 13.8 kV Karlsruhe (July
Size : 50 Up to 240 mm2 (CU) 2003) Test Report
70 Up to 240 mm2 (AL) Nos. 2003-52

b. Model Name: SEIK24


Drawing No. : 100.310.72
Rev.18
Voltage Rating: 13.8 kV
Size : 50 Up to 300 mm2 (CU)
70 Up to 300 mm2 (AL)

c. Model Name: SEIK25


Drawing No. : 100.310.73
Rev.18

3. 8 Page 174 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Voltage Rating: 13.8 kV


Size : 50 Up to 630 mm2 (CU)
70 Up to 300 mm2 (AL)

d. Model Name: SEIK33


Drawing No. : 100.310.71
Rev.15
Voltage Rating: 33 kV
Size : 70 Up to 95 mm2 (CU)
50 Up to 120 mm2 (AL)

e. Model Name: SEIK34


Drawing No. : 100.310.72
Rev.18
Voltage Rating: 33 kV
Size : 70 Up to 300 mm2 (CU)
50 Up to 300 mm2 (AL)

f. Model Name: SEIK35


Drawing No. : 100.310.73
Rev.18
Voltage Rating: 33 kV
Size : 70 Up to 630 mm2 (CU)

3. 8 Page 175 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NKT GmbH Pre-molded Termination: Tests performed at PQ Letter


GERMANY 1: Outdoor Termination NKT Nordenham/IPH Based on S&SD letter # 23-1257-1-30504401
a. Model Name: TO 36 Berlin (Feb, 2023 to dated August 14, 2023 & letter
Plant -Nordenham Size : Up to 240 mm² July, 2023) Test 23-02652-30504401 dated December 07, 2023
Rating : 33 kV Report Nos. the manufacturer is prequalified for Medium
Contact Person - +971505819959; 202302-14 Voltage indoor & outdoor termination as
+971506265187 b. Model Name: TO 36 CA confirming to National Grid SA specification #
Phone - +97143929848 Size : Up to 240 mm² Tests performed at 12-TMSS-04, with the following conditions:
Contact Person Email ID - Rating : 33 kV IPH, Type Test
[email protected]; Remark : Approved model up to size Report No. : WARRANTY
[email protected] 240 mm² only. To supply model on size (11803-20-0237) Five (5) years extended warranty/guarantee to
Website - www.NKT.com more than 240 mm², it shall be type (01319-22-0106) SEC/National Grid SA for the offered Medium
tested with the 1st project (1447.0712.3.371) Voltage indoor & outdoor termination in respect of
(05566-17-0126) the defects due to design, manufacturing,
c. Model Name: TO 24 (1447.1409.7.891) installation and workmanship from the date of
Size : Up to 240 mm² (1447.1391.6.961) Provisional Acceptance Certificate (PAC) of the
Rating : 24 kV (1447.2120897.0517 first turnkey project (in case of contract award)
) or from the date of first delivery (in case of
d. Model Name: TO 24 CA direct material supply order), as confirmed by the
Size : Up to 240 mm² manufacturer, through their Letter Ref. # CSc-ds
Rating : 24 kV dated 22.06.2023
Remark : Approved model up to size
240 mm² only. To supply model on size
more than 240 mm², it shall be type
tested with the 1st project

2: Indoor Termination
a. Model Name: TI 36
Size : Up to 240 mm²
Rating : 33 kV

b. Model Name: TI 36 CA
Size : Up to 240 mm²
Rating : 33 kV
Remark : Approved model up to size
240 mm² only. To supply model on size
more than 240 mm², it shall be type
tested with the 1st project

c. Model Name: TI 24
Size : Up to 240 mm²

3. 8 Page 176 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Rating : 24 kV

d. Model Name: TI 24 CA
Size : Up to 240 mm²
Rating : 24 kV
Remark : Approved model up to size
240 mm² only. To supply model on size
more than 240 mm², it shall be type
tested with the 1st project

Cold Shrink Termination:


1: Indoor/Outdoor Termination
a. Model Name: TC Size E
Size : Up to 240 mm²
Rating : 33 kV

Remark : Approved model up to size


240 mm² only. To supply model on size
more than 240 mm², it shall be type
tested with the 1st project

Pre-molded Plug-in Elbow Connectors

Model Name: CB 24-630


Drawing No. : 26 242 01 / 05.03.2020 /
DE-EN
Size : 95 to 300 mm²
Rating : 24kV

Model Name: CB 24-1250


Drawing No. : 26 286 38 / 14.09.2022 /
DE-EN
Size : 240 to 630 mm²
Rating : 24kV

Model Name: CB 36-630


Drawing No. : 26 286 34 / 08.05.2019 /
DE-EN

3. 8 Page 177 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Size : 95 to 300 mm²


Rating : 36kV

Model Name: CE 24-250


Drawing No. : 26 386 15 / 19.08.2016
Size : 50 to 95 mm²
Rating : 24kV

Model Name: CE 24-400


Drawing No. : 26 242 46 / 04.05.2017
Size : 95 to 240 mm²
Rating : 24kV

Pre-molded Plug-in straight Connectors

Model Name: CPI 2


Drawing No. : 26 361 03 / 11.01.2019 /
DE-EN
Size : 150 to 400 mm²
Rating : 36kV

Model Name: CPI 3


Drawing No. : 26 361 04 / 06.04.2019 /
DE-EN
Size : 240 to 630 mm²
Rating : 36kV

Total = 6

INSULATORS
4. 1
INSULATORS, STATION POST TYPE, PORCELAIN, INDOOR/OUTDOOR, 69 KV THROUGH 380 Applicable Standards: 15-TMSS-01
KV

4. 1 Page 178 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LAPP INSULATORS REDWITZ GMBH Rating 69kV-380kV M/s Lapp Insulators Redwitz GmbH Germany
GERMANY Plant Closed as per manufacturer letter dated
October 27, 2021
Plant -Bahnhofstrasse 43, 96257
Redwitz, Germany

LAPP INSULATORS LLC Rating 69kV-380kV The first batch of station post insulators shall be
United States type tested at an independent testing laboratory
in the presence of (03) National Grid Saudi Arabia
Plant -130 Gilbert Street, LeRoy, New / SEC Engineers and one approved third party
York, USA inspector. All cost pertaining to tests shall be
borne by the manufacturer.
Website - http://www.lappusa.com/

WARRANTY

Ten (10) years extended warranty in respect of


defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), shall be provided by
manufacturer against first supply.

W.S.I, Approved up to 132kV only On Hold


INDIA

Website - http://www.wsi.com/

NGK INSULATORS LTD Mitsubishi Corporation Type/Model: Tests performed:


JAPAN 5th Floor Tower A4, 8A-230202UG June 6/8, 2005, Jul.
Granada Business Park, 8A-235104MM 15, 1999, Mar 16-18,
Plant -Aichi Japan, Exit 9, Riyadh DA-222062UU 1998 & Aug. 24,
Po Box . 3254 Riyadh Rating: 380kV, 230kV & 2004
Contact Person - Mr. H. Nakane & Mr. Y 11471 KSA 115 kV Report # 053318T,
Ogawa Mr. Hahim Ibrahim 993075T, 982524T,
Email ID - [email protected] & Phone - 073727T, & 980054T
[email protected] +966-11-511-7516
Website - http://www.ngk.com/ Email: hashim.a.ibrahim@
mitsubishicorp.com

4. 1 Page 179 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LAPP INSULATORS GMBH Rating: 69kV Type tests PQ Letter


GERMANY Models: performed in Lapp Based on S&SD letter #21-01237-30504401
7.032106, 7032107 Germany lab. (2000 dated November 16 ,2021, the manufacturer is
Plant -Bahnhofstrasse 5, 95632 – 2009) prequalified for INSULATORS, STATION POST
Wunsiedel Germany Rating: 110kV Lapp Test Report TYPE, PORCELAIN, INDOOR/OUTDOOR, 69 KV
Model: 7.031906 Nos.3/00, 10/02, THROUGH 380 KV as conforming to National Grid
Contact Person - Mr. i.A. Thomas 17/09, 18/09, 19/9, SA specification #15-TMSS-01, with the following
Zembsch Rating: 115kV 20/09 conditions:
Phone - +49 (0) 92 32 / 50 15 5 Model: 7.031748
Email ID - Type Tests WARRANTY
[email protected] Rating: 132kV successfully Ten (10) years extended warranty from the date
Website - Model: 7.032310 completed at EGU & of PAC of the first turnkey project (in case of
http://www.lappinsulators.com Lapp Laboratory, contract award) or date of first delivery (in case
Rating: 230kV Test report No. of direct material supply order), as confirmed,
Model: 7.035142 11249/19 & 81/19 through their Letter # Nil dated November 15
,2021 shall be applicable for the equipment to be
Rating: 380kV supplied to SEC/National Grid SA.
Models: 7.035478, 7.035471

Rating: 380kV
Model: #7.036021.01.01.00

PPC INSULATORS (ELEKTROKERAMIK Rating: 132kV - Model 12134-518400 132kV: EGU Report Previous location was "Austria", the location has
SONNEBERG) Rating: 230kV - Model 12134-718100 no. 11382/A/20; PPC been changed to "Germany" based on
GERMANY Rating: 380kV - Model 12145-939600 Report MV manufacturer letter # Nil dated July 7, 2020
2883/2020
Plant -Sonneberg 230kV: EGU Report WARRANTY:
no. 11382/B/20; PPC Ten (10) years extended warranty from the date
Werkingstrasse 11, 96515 Report MV of PAC of the first turnkey project (in case of
Sonnenberg/Germany 2882/2020 contract award) or date of first delivery (in case
380kV: EGU Report of direct material supply order). as confirmed,
Contact Person - Mr. J.Gebhart no. 11382/C/20; PPC through their letter No. Nil dated 7 July 2020, shall
Phone - +49 3675 8730 Report MV be applicable for the equipment to be supplied to
Email ID - 2881/2020 SEC/National Grid SA.
[email protected],
[email protected]
Website -
https://www.ppcinsulators-eks.com/en
/

Total = 6

4. 1 Page 180 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

INSULATORS
4. 2
INSULATORS, PORCELAIN SUSPENSION TYPE UP TO 380kV Applicable Standards: 15-TMSS-02

Dalian Insulator Group T&D Co.,Ltd RADYA INTERNATIONAL Porcelain Cap & Pin Insulators EGU Test Reports: PQ Letter
CHINA Mohammad Afzal
Sales & Marketing U120BLD 12370/A/24 Based on S&SD letter reference OMPQ #
Plant -Dalian Manager U160BD dt.25.03.2024 10026264 dated July 09, 2023, the manufacturer
U210BD is prequalified for Porcelain Cap & Pin Insulators
No.88 East Liaohe Road, DD Port Al-Rayyan Area –Riyadh 12370/B/24dt. up to 380kV as conforming to National Grid SA
14211, K.S.A U160BP 25.03.2024 specification # 15-TMSS-02, Rev.02, with the
Dalian 00966-551611241 U210BP following conditions:
afzal.mohammad@kfbgr 12370/C/24 dt.
Contact Person - Flora Wang oup.com.sa 25.03.2024 WARRANTY
Phone - +86-0411-82168888 Ext-7017
Email ID - [email protected], 12370/D/24 dt. Ten (10) years extended warranty from the date
Contact Person Email ID - 25.03.2024 of PAC of the first turnkey project (in case of
[email protected] contract award) or date of first delivery (in case
Website - https://www.insulators.cn/ 12370/E/24 of direct material supply order), as confirmed,
dt.25.03.2024 through their Letter # Dalian/PQ/WS/001 dated
October 26, 2021 shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

4. 2 Page 181 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NGK INSULATORS LTD Mitsubishi Corporation Porcelain Fog type Disc Insulator Tests performed:
JAPAN 5h Floor tower A4, Models: May 25-June 01,
Granada Business park 132 kV 111KN 2011, March 01-13,
Plant -Aichi Japan, Exit 9 CA-825MW 2007, and March
Phone - CA-825EZ, 20-22, 2007
Contact Person - Mr. H. Nakane & Mr. Y +966-11-511-7516
Ogawa Email: hashim.a.ibrahim@ 132 kV 160KN Report # 110023T,
Email ID - [email protected] & mitsubishicorp.com CA-839MX 110024T,
[email protected] CA-839EX,
Website - http://www.ngk.com/ 070011T, 070012T,
380 kV 160 KN 120025T,
CA833MZ
CA833EX, 080027T, 080030T,
080031T
380 kV 210 KN
CA845MY 110021T, 110022T,
CA-845 EZ,

Porcelain Aero type Disc


Nsulator

230 kV, 111KN


CA-625MY
CA-625EZ

380 kV,160 KN
CA-635MZ
CA-635EZ
CA-635EW

380 kV,210 KN
CA640MY, CA640EY

Total = 2

INSULATORS
4. 3
INSULATORS, GLASS, SUSPENSION TYPE TYPE UP TO 380kV Applicable Standards: 15-TMSS-02

4. 3 Page 182 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Sediver Insulators (Shanghai) Co. Ltd. Suspension (Cap & Pin Glass) Cap & Pin Aero form PQ Letter
CHINA Insulators type (glass) Based on S&SD letter # 23- 01449/01-30504401
Insulators dated August 14, 2023, the manufacturer is
Plant -China Catalogue # 120kN, 160 kN, and prequalified for Suspension type (Cap & Pin
210 kN Glass) Insulators up to 380kV conforming to
Address: 338 Minle Road, Fengxian F-120AA/127Z National Grid SA specification # 15-TMSS-02,
Spark Zone, Shanghai 201419, China F-120AA/146Z Catalogue No. Rev.02, with the following conditions:
+86-21-57505000 F-160AD/146Z # F120AA/146Z
F-210A1/170Z # F160AD/146Z WARRANTY
Sales Office: F-120PB/146Z # F210AI/170Z •Ten (10) years extended warranty from the date
Tour Egée – 9/11 allée de l’ Arche – F-160PF/156Z of PAC of the first turnkey project (in case of
92671 Courbevoie Cedex – France F-210PP/170Z Elect. Test: contract award) or date of first delivery (in case
T037X23FM of direct material supply order), as confirmed,
Contact Person - Mohamed Gdhami dt.25.09.2023, through Letter # Nil dated July 19, 2023 shall be
Phone - +33146141548; +33652350055 T038X23FM applicable for the equipment to be supplied to
Contact Person Email ID - dt.26.09.2023, SEC/National Grid SA.
[email protected] T039X23FM
dt.25.09.2023

Pollution Test:
2101-23
dt.14.09.2023;
2102-23
dt.14.09.2023;
2103-23
dt.14.09.2023

Power Arc Test:


5161-23
dt.22.09.2023,
5162-23
dt.22.09.2023,
5163-23
dt.22.09.2023

EGU Czech Republic


Test Report
(Electrical):
12268/A/23
dt.22.12.2023
12268/B/23
dt.30.01.2024

4. 3 Page 183 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

12268/C/23
dt.22.12.2023
&12268/D/23
dt.07.02.2024

KEMA Prague Test


Reports (Power
Arc):
5223-23
dt.15.12.2023
5224-23
dt.15.12.2023
5225-23
dt.15.12.2023

4. 3 Page 184 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

YuAIZ AO – Yuzhnouralsk Insulators Energy Engineer Toughened Glass Insulators U120AD, Power Arc Tests PQ Letter
and Fitting Plant AL (JSC) Establishment Riyadh U120BP, U160AD, U160BP, U210AD, Performed: Based on S&SD letter# 19-00094-30504401
Russian Federation (EEE) U210BP VEIKI Test Report # dated January 20, 2019, the manufacturer is
Abdullah Fahhad K. 9356/VNL dated July prequalified for Toughened Glass Insulators up to
Plant -Chelyabinsk Al-Jofan (General 19-21, 2016. 380KV as confirming to National Grid SA
Manager) (U210AD) specification # 15-TMSS-02, Rev.01, with the
1 , Zavodskaya Street Yuzhnouralsk, 00966-544002245 VEIKI Test Report following conditions:
Chelyabinsk Region 457040, Russia [email protected] #9357/VNL dated
July 22, 2016 CONDITIONS
Contact Person - Mr. Vladimir (U160BP) Power Arc Test shall be performed on each
Kuznetsov VEIKI Test Report production lot at time of actual supply for models
Phone - +735134-98-5-64 #9359/VNL dated U120AD & U120BP based on S&SD letter #
July 22, 2016. 21-00175-2021 dated 04/02/2021.
(U120BP) Remaining Type & Special Tests which were not
VEIKI Test Report conducted during prequalification stage shall be
#9360/VNL dated performed on the first production lot of each type
July 22, 2016 of insulator at the time of actual supply (e.g., Low
(U120AD) Frequency Flashover, Critical Impulse, RIV,
Kema Test Report Thermal Shock, Residual Strength, Impact
DNV-GL # 5314-18 Strength, Cotter Key, Mechanical Failing Load,
dated November 02, Thermal Mechanical Performance & Pollution
2018 (U160AD) Tests etc.)
Kema Test Report All costs related to inspection & witnessing
DNV-GL # 5315-18 above mentioned tests by SEC/National Grid SA
dated November 02, engineers & Independent Inspection Agency (in
2018 (U210BP) case of contract award or direct purchase
orders shall be borne by the manufacturer.
Steep Manufacturer’s improvements /corrective
Front-of-Wave Test measures will be evaluated during sample testing
Performed: for first project supply order.
Kema Test Report
DNV-GL # 1724-18 WARRANTY
dated November 03, Ten (10) years extended warranty from the date
2018 (210BP) of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
OAO "YuAIZ of direct material supply order), as confirmed,
Factory Test Report through their Letter No. Nil dated 09/01/2019 shall
# 5601-122-2018 be applicable for the equipment to be supplied to
dated July 02 to 07, SEC/National Grid SA.
2018 (Mechanical
Failing Load,
Thermal Mechanical

4. 3 Page 185 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Performance &
Steep Wave Front
Tests for U160AD &
U210BP)

Test Report #
5601-71-2019 dated
July 29, 2019 &
5601-73-2019 dated
August 02, 2019

SEDIVER Toughened Glass (Aero form/Fog) Tests performed at:


ITALY 120kN, 160 kN, and 210 kN at Italy (Seves,
Salvi, Sveppi,
Plant -Nusco, Italy Models: Sediver Saint yore)
F12D-A/127 DC & EGU Czech
79 Avenue François Arago 92017 F12D-A/146 DC Republic
Nanterre Cedex - France F160D/146DC F21D/170DC (2006/2011/2012)
F120P/146DC Report # T048x06
Contact Person - Mr. Ibrahim Zudjelovic F160P/F210P SP/IR, T016/026x12 ,
Phone - +33 1 46 14 15 12 T054/056x11, RP LS
Email ID - [email protected] 12/043/123B/125B/1
Website - http://www.sediver.com 74. TR 26/12 & 12-1,
TR 27/12, TR 05/13,
T022x12, RP LS
11/167A, TR 23/11

4. 3 Page 186 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

VERESCENCE La Graja SL Innovative Systems Toughened Glass (Aero form/Fog) Tests performed at: PQ Letter
SPAIN (isys) 120kN, 160KN, and 210kN EGU & ZKU labs Based on S&SD letter# 13-07206-01-30504401
PO Box 60606 riyadh Models: (Czech republic). dated November 09, 2013, it is pre-qualified for
Sgd La Granja Vidrieria, S. L. Paseo Del 11555 KSA E-120DZ-146 (March 4-15, 2013) Glass insulators with the following condition:
Pocillo S/N 40100 B Granja De San Phone - E-160GDZ-146
Ildefonso (Segovia) Spain Segovia , +966-11-460-8161 E-210GDZ-170 Report # 9886/A/13, WARRANTY:
Spain Email - [email protected] E-120PPZ-146 9886/B/12, Ten (10) years extended warranty/guarantee in
E-160PZ-156 9886/D/13, and respect of defects due to design, manufacture,
Contact Person - Mr. Elias Py Rodriguez E-210PZ-170 13/044 installation & workmanship from the date of
Phone - +(+34) 917707516 E-120DZ-127 Provisional Acceptance Certificate (PAC) of the
Email ID - insulators@sgdgroup. corn first turnkey project in case of contract award or
Website - date of first delivery in case of direct material
http://www.sgdinsulators.com supply order, as confirmed by the manufacturer
thru letter #nil, dt: Nov 08, 2012.

Previously SGD LA GRANJA VIDRIERA, S.L. [The


name has been changed based on P&SFD letter
#17-03243-30504401 dated May 22, 2017].

Total = 4

INSULATORS
4. 4
INSULATORS, PORCELAIN HORIZONTAL LINE POST TYPE Applicable Standards: 15-TMSS-03

LAPP INSULATORS REDWITZ GMBH Rating 69kV-132kV M/s Lapp Insulators Redwitz GmbH Germany
GERMANY Plant Closed as per manufacturer letter dated
October 27, 2021
Plant -Bahnhofstrasse 43, 96257
Redwitz, Germany

NGK INSULATORS LTD Mitsubishi Corporation Rating: Tests performed:


JAPAN 5h Floor tower A4, 132 kV May 25-June 01,
Granada Business park 2011, March 01-13,
Plant -Aichi Japan, Exit 9 8A-69506A, 2007, and March
Phone - 20-22, 2007
Contact Person - Mr. H. Nakane & Mr. Y +966-11-511-7516 115 kV,
Ogawa Email: hashim.a.ibrahim@ 8A-69038A, 8A-69038Y Report # 102217T &
Email ID - [email protected] & mitsubishicorp.com 993499T
[email protected]
Website - http://www.ngk.com/

4. 4 Page 187 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LAPP INSULATORS GMBH Rating 69kV-132kV The first batch of horizontal line post insulators
GERMANY shall be type tested at an independent testing
laboratory in the presence of (03) National Grid
Plant -Bahnhofstrasse 5, 95632 Saudi Arabia / SEC Engineers and one approved
Wunsiedel Germany third party inspector. All cost pertaining to tests
shall be borne by the manufacturer.
Contact Person - Mr. i.A. Thomas
Zembsch
Phone - +49 (0) 92 32 / 50 15 5 WARRANTY
Email ID -
[email protected] Ten (10) years extended warranty in respect of
Website - defects due to design, manufacturing and
http://www.lappinsulators.com workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), shall be provided by
manufacturer against first supply.

Total = 3

INSULATORS
4. 5
INSULATORS, PORCELAIN, LONG ROD TYPE UP TO 380 kV Applicable Standards: 15-TMSS-04

4. 5 Page 188 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Lapp Insulators SA Porcelain Long rod Insulators Tests performed: PQ Letter


Romania Based on S&SD letter reference MPQ # 11126284
Rating : 160kN EGU Test Report # dated August 06, 2023, the manufacturer is
Plant - Romania Material / Drawing Numbers : 12119/23 dated prequalified for Porcelain long rod Insulators up to
April 05, 2023 380kV conforming to National Grid SA
Str. 22, Decembrie 1989, 7.012395.00.07.00T / 101.708.00.05 specification # 15-TMSS-04, Rev.02, with the
Nr. 31 Cluj, VEIKI Test Report # following conditions:
12963/VNL dated
Contact Person - Thomas Zembsch May 11, 2023 WARRANTY
Phone - +49 (0) 92 32 / 50 15 5 Ten (10) years extended warranty from the date
Email ID - of PAC of the first turnkey project (in case of
[email protected] contract award) or date of first delivery (in case
Website - of direct material supply order), as confirmed,
http://www.lappinsulators.com through their Letter # WC-MPQ 11126284-class
1(b) 2022 dated December 14, 2022 shall be
applicable for the equipment to be supplied to
SEC/National Grid SA.

TYPE TEST:
The first batch of each Insulator model to be
supplied to SEC/National Grid SA (other than type
tested already) as per 15-TMSS-04, shall be type
tested (Type / Special tests) at an accredited
independent laboratory in the presence of three
(3) SEC/National Grid SA Engineers and one (1)
SEC/National Grid SA approved IIA Inspector as
confirmed through manufacturer Letter #
TTC-MPQ 11126284-class 1(b) 2022 dated
December 14, 2022. All cost of which shall be
borne by manufacturer.

4. 5 Page 189 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Zapel SA Innovative Systems 132kV Long Rod Porcelain Insulators Type test performed PQ Letter:
Poland (ISys) 160KN at KEMA Laboratory Based on S&SD letter # 17-04625-01-030504401
P.O.Box 60606, Riyadh Dwg. # 032Z-15 & 033Z-15 Prague dated June 07,2017, Zapel SA Poland is
Plant -Poland 11555 120KN Report# 5024-17 & pre-qualified for 132kV Long Rod Porcelain
Dwg. # 158Z-15 & 159Z-15 5025-17 dated Insulators as conforming to National Grid SA
Zapel SA Techniczna 1 36-40, local Contact Person: 10-03-17 specification # 15-TMSS-04, with the following
Boguchwala, Poland Mr. Kamal Al Muhanna Drawing # 032Z-15 conditions:
Mobil# +966 -505491067 & 033Z-15
Contact Person - Mr. Wojciech Sztaba +966 (11) 4608160, +966 WARRANTY:
Phone - +48178720100 (11) 4608161 Type test performed • Ten (10) years extended warranty from the
Email ID - [email protected] [email protected] at EGU HV date of PAC of the first turnkey project (in case
Contact Person Email ID - laboratory Praha of contract award) or date of first delivery (in
[email protected] dated 10.03.2017 case of direct material supply order), as
Website - confirmed, through their Letter No. NIL dated
http://www.zapel.com.pl/en/products/i Report #10573/A/17 30/05/2016 shall be applicable for the equipment
nsulators/ Report #10573/B/17 to be supplied to SEC/National Grid SA.
Report #10573/C/17
Report #10573/D/17
Report #10576/A/17
Report #10576/B/17

Drawing #
032Z-15
033Z-15
159Z-15
158Z-15
032Z-15
033Z-15

LAPP INSULATORS REDWITZ GMBH Rating 69kV-380kV M/s Lapp Insulators Redwitz GmbH Germany
GERMANY Plant Closed as per manufacturer letter dated
October 27, 2021
Plant -Bahnhofstrasse 43, 96257
Redwitz, Germany

4. 5 Page 190 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NGK INSULATORS LTD Models: Tests performed:


JAPAN Nov. 13-Dec. 03
380 kV,160 kN 2008/March 23-27,
Plant -Aichi Japan, CA45469A 2009 & March
CA45578A 12-21, 2012
Contact Person - Mr. H. Nakane & Mr. Y CA45461A, CA45570A Report # 080040T,
Ogawa CA45473A 090008T,
Email ID - [email protected] & CA45568A 090009T, 080041T,
[email protected] 090006T, 080041T,
Website - http://www.ngk.com/ 380 kV, 330 KN 090007T, 120015T,
CA45471A,
CA45579A,
CA45434C
CA45569A
CA45472A, CA45571A

132kV, 120 KN

CA45501A
CA45503A
CA45514A
CA45516A

132 KV, 160 KN

CA45502A
CA45504A
CA45515A
CA45517A

4. 5 Page 191 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LAPP INSULATORS GMBH • Rating : 160kN Tests performed at: Based on S&SD letter # 18-01028-30504401
GERMANY Material / Drawing Numbers: dated February 27, 2018, Type/Model Rating for
7.012395.00.07.00 / 101.708.00.05; EGU HV LAPP Insulators Germany is updated.
Plant -Bahnhofstrasse 5, 95632 7.012397.00.07.00 / 101.710.00.05; (2009/2010/2011/20
Wunsiedel Germany 7.012724.00.07.00 / 101.740.00.05; 13)
7.012700.01.07.00 / 101.713.01.05; Report #
Contact Person - Mr. i.A. Thomas 7.012725.00.07.00 / 101.741.00.05 01/09, 02/09, 46/13,
Zembsch 41/13, 75a/09,
Phone - +49 (0) 92 32 / 50 15 5 • Rating : 210kN 9763/11, 40/13,
Email ID - Material / Drawing Numbers: 42/11, 21/10,
[email protected] 7.012396.00.07.00 / 101.709.00.05 10129/A/14 dated
Website - July, 2014,
http://www.lappinsulators.com • Rating : 330kN 10614/A/17
Material / Drawing Numbers: (18-02-17),
7.012719.01.07.00 / 101.735.01.05; 10702/B/17
7.012398.00.07.00 / 101.711.00.05; (13-07-17)
7.012716.01.07.00 / 101.731.01.05;
7.012754.01.07.00 / 101.771.01.05 Type tests
7.012753.01.07.00 / 101.770.01.05 performed in
Lapp Germany lab.
(2009-2013)
Lapp Test Report
Nos.01/09, 02/09,
46/13,41/13,
75a/09, 9763/11,
40/13,42/11, 21/10,
40/13, 15/17
(24-01-17),

KEMA DNV-GL:
5275-18 (26-10-18)

Type tests
performed in
EGU Laboratory,
Czech Republic
26.04.2021
Lab Test Report:
11630/A/21 &
11630/B/21

4. 5 Page 192 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PPC INSULATORS (ELEKTROKERAMIK Rating: Tests performed at: PQ Letter


SONNEBERG) 160, 330kN EGU HV, Kloknar Based on TS&SD/ESD e-mail 07/07/2010 & PPC
GERMANY 31/40/50 mm/kV Institute & ZKU Insulators (ELEKTROKERAMIK SONNEBERG,
(May/June, 2012) Germany) Letter # Nil dated 4th July 2010, it is
Plant -Sonneberg Models: Report # 9807/A & pre-qualified for Long Rod Porcelain Insulators up
75/18+17/1450 B/12, 9829/A, B, C, to 380 kV with following conditions:
Werkingstrasse 11, 96515 105/18+17/1545 D, E/12 152 &
Sonnenberg/Germany 85/22+21/1760 153/12/AL, 169 & WARRANTY:
105/21+21/1760 183/12/AL, 12-081 & Ten (10) years extended warranty/guarantee in
Contact Person - Mr. J.Gebhart 95/23+22/1860 082, 2014-0789 & respect of defects due to design, manufacture,
Phone - +49 3675 8730 790, 12-118, 14-222 installation & workmanship from the date of
Email ID - & 223, 10154 A, B, Provisional Acceptance Certificate (PAC) of the
[email protected], C, D, E & F, first turnkey project in case of contract award or
[email protected] 2012-0473 & 74, date of first delivery in case of direct material
Website - 9844/A, B, C, D/12, supply order.
https://www.ppcinsulators-eks.com/en 13-035, 036 & 037.
/

Total = 6

INSULATORS
4. 6
INSULATORS, COMPOSITE, HORIZONTAL LINE POST, SUSPENSION AND TENSION TYPE (UP Applicable Standards: 15-TMSS-05
TO 230 KV)
PFISTERER Insulators Wunseidel GmbH MODULAR DESIGN Type tests Prequalified for MODULAR TYPE DESIGN
GERMANY 115 kV 120/160 kN conducted at LAPP insulators
Germany lab
Plant -Wunsiedel - Germany Model:
14K3349 & 50 Test Report No. Previously "’Lapp Insulators GmbH"
Bahnhofstrasse 5 28/13 & 29/13
95632 Wunsiedel 230 kV
Germany 120/160 kN

Wunsiedel - Germany Model:


7.09538 & 39
Contact Person - Alexandra Schlecht
Phone - +49718170050
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.pfisterer.com

4. 6 Page 193 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

E.B. REBOSIO S.R.L MOLDED DESIGN Prequalified for MOLDED TYPE DESIGN insulators
ITALY up to 132 kV

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

-------------
PQ Letter
Based on S&SD letter# 18-03367-02-30504401
dated October 29, 2018 M/s E.B. Rebosio S.r.l,
Italy (previously prequalified up to 132kV) is
prequalified for Composite Suspension and
Tension Insulators up to 230kV as conforming to
National Grid Saudi Arabia Material Specification
15-TMSS-05, Rev.02 with the following condition:
Type Test:
The first project of 230kV Composite Insulators,
per 15-TMSS-05, to be supplied to SEC/National
Grid SA shall be type, special and routine tested
in presence of three (3) SEC/National Grid SA
and one (1) SEC/National Grid SA approved IIA
Inspector as confirmed through Manufacturer
Letter # Nil dated September 13, 2018. All cost of
which shall be borne by E.B. Rebosio S.r.l, Italy.

Warranty
Ten (10) years extended warranty from the date
of PAC of the turnkey project for 230kV in case
of contract award or date of delivery in case of
direct material supply order, as confirmed by the
manufacturer through letter # Nil dated
September 04, 2018.

4. 6 Page 194 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FCI (FURUKAWA COMPOSITE LSR DESIGN Prequalified for LSR TYPE DESIGN insulators
INSULATORS LTD)
HUNGARY

Budapest , Hungary

Website - http://www.fcifurukawa.hu

MACLEAN POWER SYSTEM MODULAR DESIGN Prequalified for MODULAR TYPE DESIGN
United States insulators

Plant -7801 Park Place Road

York, South Carolina


29745, USA

Contact Person - Mr. Ms. Anabel


Gdriozola
Contact Person Email ID -
[email protected]
Website - http://
http://www.macleanpower.com/

NGK LOCKE INC. Mitsubishi Corporation MOLDED DESIGN Tests performed: Prequalified for MOLDED TYPE DESIGN insulators
United States 5h Floor tower A4, 111 kN,160 kN (2011 & 2012)
Granada Business park Report # 120014T
Virginia Beach, Va, Usa Exit 9
Phone -
Contact Person - Mr. H. Enomoto +966-11-511-7516
Email ID - [email protected] Email -
Website - http://www.ngk-locke.com/ hashim.a.ibrahim@mitsu
bishicorp.com

4. 6 Page 195 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

XIANGYANG GUOWANG COMPOSITE RADYA International Molded Design KEMA Test Report # Prequalifed for MOLDED TYPE DESIGN insulators
INSULATORS CO. PO Box: 61891 Riyadh TIC 2659-13 dated up to 132 kV only.
CHINA 14211 K.S.A. Rating March 21, 2014
+966-11-4966667 69kV-132kV WARRANTY:
Plant -Xiangyang city, China. afzal.mohammad@kfbgr KEMA Test Report # Ten (10) years extended warranty/guarantee in
oup.com.sa Model # FXB5-132/111SB (111kN) TIC 2660-13 dated respect of defects due to design, manufacture,
No.10, Dengman Road, High & New March 21, 2014 installation & workmanship from the date of
Tech Park, Industry District, Xiangyang, Model # FXB5-132/160SB (160kN) Provisional Acceptance Certificate (PAC) of the
Hubei 441057, P.R China EGU Test Report # first turnkey project in case of contract award or
9963/A/13 dated date of first delivery in case of direct material
Contact Person - Mr. Wang Xin November 29, 2013 supply order shall be given for the proposed 132
Phone - Tel: 0086-710-3262531,Fax: kV composite insulators
0086-710-3250621 EGU Test Report #
9963/B/13 dated The warranty/ guarantee shall be applicable from
November 29, 2013 first project and shall cover all the cost of
materials and labor as per warranty / guarantee
of materials and subsequently reduced yearly in
case of future project award. This was agreed
through the manufacturer letter # GCR-06-02
dated 2015-07-08.

Note:
Previously “XIANGFAN GUOWANG”, the name
has been changed to “Xiangyang Guowang
Composite Insulators Co. Ltd.” based on the
manufacturer letter # RI/PQ/
XYGW/TT132/2015/008 dt: August 09, 2015 and
the supporting documents approved by the
concerned authorities in China.

Total = 6

INSULATORS
4. 7
INSULATORS, COMPOSITE, HORIZONTAL LINE POST, SUSPENSION AND TENSION TYPE (UP Applicable Standards: 15-TMSS-05
TO 380 KV)

4. 7 Page 196 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFISTERER Insulators Wunseidel GmbH MODULAR DESIGN Prequalified for modular type design insulators
GERMANY Rating: Tests Performed: CONDITION:
160 kN-380 kV Type tests Any new type of Insulators (other than the types
Plant -Wunsiedel - Germany conducted at LAPP already tested) offered by Lapp, Germany shall
Model – Germany lab, EGU & be Type Tested in presence of three (3) SEC
Bahnhofstrasse 5 Rodurflex CS160SB30/79 ZKU Engineers and one (1) Approved Independent
95632 Wunsiedel (195/163)4900 Agency Inspector.
Germany 7.095670.80.01.00/ Lapp Germany Test
7.095670.80.22.00 Report No. 29/13, dt: WARRANTY:
Wunsiedel - Germany 09/04/2013 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Contact Person - Alexandra Schlecht EGU Test Report installation & workmanship from the date of
Phone - +49718170050 No.9898/A/13 from Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] 03/04/2013 to first turnkey project in case of contract award or
Contact Person Email ID - 08/04/2013. date of first delivery in case of direct material
[email protected] supply order
Website - www.pfisterer.com ZKU Test Report No.
13-059, dated:
05/04/2013 Previously "’Lapp Insulators GmbH"

4. 7 Page 197 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFISTERER Czech s.r.o CEPCO Molded design Type Tests PQ Letter


CZECH REPUBLIC Jeddah, KSA 160kN, Performed: Based on S&SD letters # MPQ1243304-Class I(b)
+966 503659251 Drawing No. -2017 dated 07th July, 2019 it is pre-qualified for
Plant -Kadan 138 206 588 BC EGU Test Report # composite insulators suspension and tension
beshrdawalibi@cepco-s 11109/A/19 dated type (up to 380kV) as conforming to National Grid
Kadan - Kralovsky Vrch 1977 a.com April 10, 2019 SA with specification # 15-TMSS-05 Rev.02 with
EGU Test Report # the following conditions:
Phone - +41 41 499 74 71 ; +41 79 318 11109/B/19 dated
17 32 April 10, 2019 WARRANTY
Email ID - [email protected] EGU Test Report # Ten (10) years extended warranty from the date
; [email protected] ; 11109/C/19 dated of PAC of the first turnkey project (in case of
[email protected] ; April 10, 2019 contract award) or date of first delivery (in case
[email protected] Kema Test Report of direct material supply order), as confirmed,
Website - www.pfisterer.com DNV.GL # 5074-19 through their Letter No. Nil dated April 6, 2018
dated April 04, 2019 shall be applicable for the equipment to be
Kema Test Report supplied to SEC/National Grid SA.
DNV.GL # 5075-19
dated April 04, 2019 Any new type of Insulators (other than the types
Klokner Institute Test already tested) offered by manufacturer shall be
Report # 67/19/AL type tested in presence of three (3) SEC / NG SA
dated March 18, Engineers and one (1) Approved Independent
2019 Agency Inspector.
Pfisterer Test Report
# PI 1076 dated Previous Plant located at Werkstrasse 7, 6102
March 13, 2019. Malters, Switzerland (prequalified vide TS&SD
letter # 10-02374-03032301, dated August 18,
2010) has been shifted to new location in Kadan
Czech Republic.

4. 7 Page 198 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

E.B. REBOSIO S.R.L Molded design PQ Letter


ITALY
Based on S&SD letter# 18-03367-01-30504401
dated October 01, 2018 M/s E.B. Rebosio S.r.l,
Italy (previously prequalified up to 132kV) is
prequalified for Composite Suspension and
Tension Insulators as conforming to National Grid
Saudi Arabia Material Specification 15-TMSS-05,
Rev.02 with the following condition:

Type Test:
The first project of 380kV Composite Insulators,
per 15-TMSS-05, to be supplied to SEC/National
Grid SA shall be type, special and routine tested
in presence of three (3) SEC/National Grid SA
and one (1) SEC/National Grid SA approved IIA
Inspector as confirmed through Manufacturer
Letter # Nil dated September 13, 2018. All cost of
which shall be borne by E.B. Rebosio S.r.l, Italy

Warranty
Ten (10) years extended warranty/guarantee
from the date of (PAC) of the Turnkey project (In
case of contract award) and from the date of
delivery for the direct material supply order. The
guarantee/warranty shall be applicable from first
project and shall cover all the cost of materials
and labor as per warranty/guarantee of materials
and workmanship and subsequently reduced
yearly in case of future project award. This was
confirmed in writing by E.B.REBOSIO S.r.L, Italy
through their letter # nil dated # September 04,
2018.

4. 7 Page 199 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MACLEAN POWER SYSTEM Yousif Al Hobays Office MODULAR DESIGN Type tests Prequalified for MODULAR TYPE DESIGN
United States for Trading Service conducted at EGU, insulators
PO Box 301134 Riyadh Model: ZKU,Klokar &
Plant -7801 Park Place Road 11372 Saudi Arabia Cat./Drawing S678192 VG03 KFUPM WARRANTY:
Email:[email protected] Ten (10) years extended warranty/guarantee in
York, South Carolina m EGU Test Report respect of defects due to design, manufacture,
29745, USA No.9447/08 dt: installation & workmanship from the date of
18/11/2008. Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. Ms. Anabel first turnkey project in case of contract award or
Gdriozola EGU Test Report date of first delivery in case of direct material
Contact Person Email ID - No.9449/08 dt: supply order, as confirmed by the manufacturer
[email protected] 16-17/12/2008 through their letter no.RI/MCLN/SEC/AS, dt: 5th
Website - http:// April, 2007.
http://www.macleanpower.com/ ZKU Test Report No.
08-109, dt:
21/10/2008)

Kolkar Test Report


No. 465/08/AL, dt:
19/11/2008)

KFUPM Test Report


No. QCER2059, dt:
06/01/2009)

4. 7 Page 200 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NGK LOCKE INC. Mitsubishi Corporation MOLDED DESIGN Tests performed: Prequlified for MOLDED TYPE DESIGN insulators
United States 5h Floor tower A4, July 01-05, 2008,
Granada Business park 380 kV,178 kN July 25-27, 2011 and PQ Letter
Virginia Beach, Va, Usa Exit 9 April 20-27, 2005 Based on TS&SD letter #
Phone - 402-SL1370-SK-95 10-F02356/02-03032301 dated 22/11/2010, it is
Contact Person - Mr. H. Enomoto +966-11-511-7516 Report # pre-qualified for 380 kV Composite Insulators:
Email ID - [email protected] Email:hashim.a.ibrahim@ 380 kV,222 kN 080022T (For 380
Website - http://www.ngk-locke.com/ mitsubishicorp.com Models: kV, 178 kN WARRANTY:
Insulators) Ten (10) years extended warranty/guarantee in
50B-SL1370-SK-95 110036T & 050028T respect of defects due to design, manufacture,
50B-SL1370-SK-59 (For 380kV, 222kN installation & workmanship from the date of PAC
502-SL1770-SK-95 Insulators) of the turnkey project in case of contract award
502-SE1570-SK-15 or date of delivery in case of direct material
230 kV,160 kN 120014T, supply order.
36B-SS1140-SK-08 PO3031T,
230 kV,111 kN 030058T,
251-SL970-3J-09 TN-NCI-98143
TN-NCI-2000009 R1
132 kV, 160 kN

36B-SS620-SK-0A

132 kV 111 kN

25A-SL540-SJ-0A

115 kV,160 kN

36B-SL510-SK-0A

115 kV,111 kN
25A-SL440-SJ-0A

Total = 5

INSULATORS
4. 8
RTV SILICON RUBBER INSULATOR COATING Applicable Standards: 15-TMSS-07

4. 8 Page 201 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MIDSUN GROUP, Inc. Desert World Company Midsun HVIC G W/ATH (Part No. Type Tests PQ Letter
United States 122 St., Road# 23,2nd S2622MMS-G-ATH) Performed: Based on S&SD letter # 19-03636-30504401
Industrial City, Dammam, - ITE Test Report # dated December 30, 2019, MPQ110914-Class I(b)
Plant -USA Kingdom of Saudi Arabia IE-ITE-200316-01/M2 -2016 the manufacturer is prequalified for RTV
+966 50262 2222; +966 / EN dated Silicon Rubber Insulator Coating as conforming to
GACO Western Factory (owned by 549228800 September 09, 2021 National Grid SA specification # 15-TMSS-07
Firestone Building ProductsCompany [email protected] (Tracking and Rev.01, with the following conditions:
LLC, manufactures RTV Coating for Erosion / 1000hrs
M/s Midsun), 1245 Chapman Drive, Salt fog) WARRANTY
Waukesha, WI 53186, Wisconsin, USA - ITE Test Report # Ten (10) years extended warranty from the date
IE-ITE-200316-02/M2 of PAC of the first turnkey project (in case of
Contact Person - Mr. Robert F. Vojtila / EN dated contract award) or date of first delivery (in case
Phone - +1 860-378-0100 Ext. 112 September 09, 2021 of direct material supply order), as confirmed,
Contact Person Email ID - (Tracking and through their Letter No. Nil dated December 13,
[email protected] Erosion Resistance) 2016 shall be applicable for the equipment to be
- ITE Test Report # supplied to SEC/National Grid SA.
IE-ITE-200316-03/M2
/ EN dated
September 09, 2021
(Dry arc
Resistance)
- ITE Test Report #
IE-ITE-200316-04/M2
/ EN dated
September 09, 2021
(High Pressure
Water Withstand)
- ITE Test Report #
IE-ITE-200316-05/M2
/ EN dated
September 09, 2021
(Adhesion)
- ITE Test Report #
IE-ITE-211045/EN
dated December 03,
2021 (Contact
Angle)

4. 8 Page 202 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

M/s BRB International Saudi Conduit Coating & BRB Si-COAT 570hs HVIC Type Tests PQ Letter
NETHERLANDS Contracting Company Performed: Based on S&SD letter # MPQ8860314 dated
P O Box 41044, First • EGU Test January 04, 2022, the manufacturer is
Plant -Ittervoort - Netherlands Industrial City, Dammam Report # 11762/21 prequalified for RTV Silicon Rubber Insulator
31521 dated December 20, Coating Material BRB Si-COAT 570hs HVIC as
Europastraat 5 - 6014 CD +966554551283 2021 (Tracking and conforming to National Grid SA specification #
Ittervoort, The Netherlands [email protected]. Erosion / 1000hrs 15-TMSS-07 Rev.01, with the following
sa Salt fog, Tracking conditions:
Ittervoort and Erosion
Resistance and Dry WARRANTY
Contact Person - Marc Ladreyt Arc Resistance) Ten (10) years extended warranty from the date
Phone - +31 646 757 078 • BRB Lab Test of PAC of the first turnkey project (in case of
Email ID - [email protected] Report # contract award) or date of first delivery (in case
Contact Person Email ID - HVIC570hs-001- of direct material supply order), as confirmed,
[email protected] 122021 dated through their Letter No. Nil dated September 11,
Website - www.brb-international.com December 02, 2021 2020 shall be applicable for the equipment to be
(Adhesion) supplied to SEC/National Grid SA.
• BRB Lab Test
Report #
HVIC570hs-002-
122021 dated
December 02, 2021
(High Pressure
Water Withstand).
• Material
Xpertise Report #
20211115-1 dated
December 06, 2021
(Contact Angle)
• ITE Test Report
# IE-ITE-230269/EN
dated May 22, 2023
(Finger Printing by
Thermogravimetric
Analysis /TGA,
Fourier Transform
Infrared
Spectroscopy /FTIR
& Density
Measurement).
• EGU Test
Report # 12150/23

4. 8 Page 203 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

dated May 29, 2023


(Hydrophobicity
Transfer).

WACKER Chemie AG WACKER Chemicals POWERSIL® N552 Type Tests Based on S&SD letter # 22-00600-30504401
GERMANY Middle East FZE (Local Performed: dated May 19, 2022, the manufacturer is
sales office) prequalified for RTV Silicon Rubber Insulator
Plant -Burghausen, Germany Contact Person: • EGU Report # Coating Material POWERSIL® N552 as conforming
Mohammed Sanaobar 11702/21 dated to National Grid SA specification # 15-TMSS-07
Johannes-Hess-Str. 24 Regional Technical October 04, 2021 Rev.01, with the following conditions:
84489 Burghausen, Germany Director - Dubai (Tracking and
mohammed.sanaobar@ Erosion / 1000hrs • Ten (10) years extended warranty from the
Munich, Germany ( Head office) wacker.com Salt fog) date of PAC of the first turnkey project (in case
Mobile: • CPRI Report # of contract award) or date of first delivery (in
Contact Person - Dr. Martin +971 50 4514272 CPRIBLRHVDMISC20 case of direct material supply order), as
Bortenschlager T0572 dated confirmed, through their Letter No. Nil dated
Phone - +49 8677 83-0 or +49 89 PO Box 341071, Dubai December 29, 2020 March 19, 2020 shall be applicable for the
6279-0 Silicon Oasis (Tracking and equipment to be supplied to SEC/National Grid SA.
Email ID - Dubai - U.A.E. Erosion Resistance)
[email protected] Tel.: +971 4 709 9999 • CPRI Report #
Contact Person Email ID - Fax: +971 4 709 9911 CPRIBLRCDDMATMI
[email protected] +971 4 7099999 SC20T0090 dated
Website - www.wacker.com October 15, 2020
mohammed.sanaobar@ (Dry arc
wacker.com Resistance)
• Intertek Report
# IR 03 Rev.02 dated
November 8, 2020
(High Pressure
Water Withstand)
• Intertek Report
# IR 03 Rev.02 dated
November 8, 2020
(Adhesion)
• University of
Applied Sciences
Germany Report #
VB 28/18 dated
December 14, 2018
(Contact Angle)

4. 8 Page 204 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CSL SILICONES INC. Saudi Conduit Coating & Si-Coat 570hs SGS Test Report # PQ Letter
CANADA Contracting Company SUR-15135-02_rev0 Based on S&SD letter# 15-06643-01-30504401
PO Box 41044 3 dated January 06, dated August 26, 2015, it is pre-qualified for RTV
Plant -Canada First Industrial City 2016 (High Silicone Rubber Insulator Coating Material
Dammam 31521 Pressure Water “Si-Coat 570hs” as conforming to National Grid
144 Woodlawn Road West Kingdom of Saudi Arabia Withstand Test, SA specification # 15-TMSS-07, with the
+966138473288, Adhesion Test and following conditions:
Guelph +966554551283 Contact Angle Test)
[email protected] WARRANTY:
Contact Person - Abdus Samad Hashmi a Ten (10) years extended Warranty for the
- Project Managment Supervisor ; proposed RTV Silicone Rubber Insulator Coating
Bharat Poojara - Indigo FZC Material “Si-Coat 570hs” in respect of the defects
Phone - +1 519 836 9044 due to design, manufacturing and workmanship
Email ID - from the date of the Provisional Acceptance
[email protected] Certificate (PAC) of the project (in case of
Contact Person Email ID - Abdus Samad contract award) and from the date of delivery for
Hashmi: [email protected] ; the direct material supply order shall be provided
Bharat Poojara: as confirmed through the manufacturer letter # Nil
[email protected] dated 05-08-2015.
Website - www.cslsilicones.com

4. 8 Page 205 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DOW CORNING CORPORATION Saudi Conduit Coating & Xiameter” ECE-3650 SGS Report # PQ Letter
AUBURN Contracting Company 3508910#10 dated Based on S&SD letter# 16-01841-02-30504401
United States PO Box 41044, November 09 & 25, dated April 10, 2016 , S&SD letter #
First Industrial City 2015 and Dec 08, 14-04590-02-30504401, dated 16th September
Pike Rd Industrial Estate, Tilmanstone, Dammam 31521, 2015 (Contact Angle 2014, it is prequalified for RTV Silicone Rubber
Kent CT15 4NL Kingdom of Saudi Arabia Test, Dry Arc Insulator Coating Material “Xiameter” ECE-3650
Auburn , United States Tel: +966 13 847 3288, Resistance Test, Sylgard HVIC with the following conditions:
+966554551283 Tracking and
Email ID - [email protected] Mr. Hisham Koya, Email: Erosion Resistance WARRANTY:
[email protected] Test, Tracking and Ten (10) years extended warranty/guarantee in
a Erosion Test / Salt respect of defects due to design, manufacture,
fog 1000 hrs). installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
SGS Report # first turnkey project in case of contract award or
R/051/IND/JD/12 date of first delivery in case of direct material
dated May 27, 2012 supply order.
(Adhesion Test).

SGS Report #
R/099/IND/JD/11
dated June 14, 2011
(High Pressure
Water Withstand
Test).

Total = 5

POLES, TOWERS, STRUCTURES AND LINE SUPPORTS


5. 1
TRANSMISSION LINE AND SUBSTATION LATTICED STEEL STRUCTURES UP TO 380KV Applicable Standards: 20-TMSS-01

AL-BABTAIN POWER&TELECOM CO. Pre-qualified for Transmission Line & Substation


EGYPT Steel Structures up to 380kV with the following
conditions:
Website -
http://www.al-babtain.com.sa/ WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

5. 1 Page 206 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AL-SALAM INSDUTRIES AND TRADING Only one trial 110/132kV transmission line project
EST./ADVANCE TECHNOLOGIES. only (short line)
Saudi Arabia

Jeddah , Saudi Arabia

AL BABTAIN POWER&TELECOM CO Change of location from Al-Sulai Industrial area,


Saudi Arabia Riyadh to 3rd Industrial City, Dammam

Plant -3rd Industrial City, Dammam

P.O. Box: 589, Abqaiq 31992

DAMMAM

Contact Person - Mr. Fawaz Zain


Al-Abidin
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.al-babtain.com.sa/

AL YAMAMAH ELECTRIC POWERS PQ Letter


FACTORY Based on TS&SD letter # 11-03472-03032301
Saudi Arabia dated 09/01/2011, letter # 13-05834-30504401-01
dated September 29, 2013 and letter #
Al Khurma King Faisal Street 12-0054-30504401 dated January 10, 2012, it is
Jeddah,P.O.Box – 30844, Jeddah pre-qualified for Transmission Line Steel
21487, Structures (Latticed) up to 380 kV & Substation
Steel Structures (Latticed) up to 132 kV with the
Contact Person - Mr. Yousef El Sayed following condition:
Phone - +966-12-2889323
Email ID - [email protected] WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 21 Oct, 2009 and letter no. nil.
Dt: 07 Jan, 2012.

5. 1 Page 207 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AL ZAMIL STEEL SUSPENDED based on S&SD letter #


Saudi Arabia 22-00512-30504401 dated April 17, 2022.

1St Industrial City , 2Nd Industrial City


Dammam,P.O.Box – 877, Dammam
31421

Contact Person - Mr. Annoni Giovanni


(Sale Manager)
Phone - +966-13-8121120 x 6868
Email ID -
[email protected]

ALASHHOURY INDUSTRY PQ Letter


Saudi Arabia Based on S&SD letter # 15-09504-01-30504401
dated December 14, 2015, it is pre-qualified for
Riyadh, Saudi Arabia fabrication & galvanization of latticed steel
structures for Substation Gantries and Equipment
Support Structures up to 380 kV as conforming
to National Grid SA specification # 20-TMSS-01,
with the following conditions:

WARRANTY
Ten (10) years Extended Guarantee / Warranty
from the date of PAC of first Project (in case of
contract award) or from the date of delivery for
the direct material supply order,as confirmed
through their Letter # Nil dated 04/01/2015.

5. 1 Page 208 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SA RA ENERGY, CONSTRUCTION, PQ Letter


TRADE AND INDUSTRY CO. INC. Based on S&SD letter# 14-09052-01-30504401
TURKEY dated 11th December 2014, it is pre-qualified for
Transmission Line and Substation Steel
Plant -Polatli (Ankara) & Adana Structures up to 380 kV with the following
(Aadna), Turkey conditions:

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

5. 1 Page 209 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ENERGYA STEEL SOLUTION (HESHAM latticed steel Based on S&SD letter # 15-10909-02-30504401
HELAL EL SEWEDY & PARTNERS FOR structures up to 380 kV dated February 10, 2016 , TS&SD letter#
STEEL INDUSTRIES CO.) 09-2179/07-03032301 dated November 11, 2009,
Saudi Arabia approval of Executive Directive for TS&SD letter#
09-02179/06-03032301 dated November 11, 2009
Rabigh – Yanbu High Way Exit 927 & based on S&SD letter# 13-01978/01-30504401
Industrial Zone Aramco Road dated June 10, 2013, it is pre-qualified for

Contact Person - Mr. Ahmed Khan , Mr. - Substation Steel Structures up to 380 kV
Rayan A. Taj
Phone - +966-5609678655 Tel: +966 - Transmission Towers for projects up to 380
500150706 ,Fax: +966 500576159 kV(Except design)
Email ID - [email protected]
Contact Person Email ID - and
[email protected], - Communication Towers for Transmission
[email protected] Sector
,[email protected]
with the following condition:

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order
This was confirmed, through their Letter # nil
dated October 14, 2014.

GEYARD FOR COMMERCE AND IMPORT Prequalified for Substation Steel Structures only
CO.
Saudi Arabia

Al Khobar , Saudi Arabia

5. 1 Page 210 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HIDADA SUSPENDED for all SEC/National Grid SA ongoing


Saudi Arabia and forthcoming projects based on VP,
Engineering letter # 21-00877-30504401 dated
Plant -Phase 2 Jeddah Industrial City August 03, 2021.
Jeddah

Po Box 11809 , Jeddah 21463 Saudi


Arabia

Phone - +966- 12-637-4450


Email ID - [email protected]
Website - http://www.hidada.com.sa/

KEC INTERNATIONAL LTD. Pre-qualified for Transmission Line & Substation


INDIA Steel Structures up to 380kV with the following
conditions:
Plant -Nagpur-Butipori, Jabalpur And
Jaipur CONDITION:
Only NAGPUR-BUTIPORI, JABALPUR & JAIPUR
Website - http://www.kecrpg.com/ Plants areacceptable.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

5. 1 Page 211 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KALPATARU POWER TRANSMISSION Based on TS&SD letter 09-00665/1-03032301


LTD. dated 16th. March 2009 it is pre-qualified for
INDIA Galvanized Transmission Line Lattice Steel
Structures with the following conditions:
Gujarat , India
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
through their letter no.nil, dt: 01.12.2008..

LARSEN & TOUBRO LTD


INDIA

Chennai , India

Website -
http://www.larsentoubro.com/

NAJEM Prequalified for Substation Steel Structures only


Saudi Arabia

5. 1 Page 212 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR STEEL SUSPENDED - Manufacturer changed location to


Saudi Arabia Jubail - Saudi Arabia

Riyadh , Saudi Arabia PQ Letter


Based on TS&SD letter# 08-1058/1-03032301
Riyadh dated 25th May 2009 it is pre-qualified for
Transmission Towers for projects up to 132 kV,
Contact Person - Sultan Alghamdi " VIP Substation & Gantry Steel Structures up to 380
key Account Manegr "; Saleh kV and Communications Towers for transmission
Almehaijeen "Projects Sales Engineer " sector with the following conditions:
Phone - 920006111
Contact Person Email ID - WARRANTY:
[email protected]; Ten (10) years extended warranty/guarantee in
[email protected] respect of defects due to design, manufacture,
Website - installation & workmanship from the date of
http://www.alfanarconstruction.com Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
through their letter no. AS/2009/0704/001, dt: 7th
April, 2009..

ARABIAN INTERNATIONAL CO.


Saudi Arabia

Jeddah , Saudi Arabia

Email ID - [email protected].
Website - http://www.aicsteel.com/

5. 1 Page 213 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Alfanar Steel Type tests PQ Letter:


Saudi Arabia successfully Based on TS&SD letter#
completed for 132kV 08-1058/1-03032301dated 25th May 2009 &
Plant -Al Jubail Industrial City Tower type S&SD Letter #MPQ1342325-Class I(a)-2017
D132E1/F1 at Al dated January 12, 2022, Manufacturer is
Jubail industrial area Main Road no. 138 Babtain Tower pre-qualified for transmission line and substation
Link Road no. 150 Testing Station, latticed steel structures up to 380kV conforming
Riyadh KSA, to National Grid SA Specification # 20-TMSS-01
(+966) 56 308 6695; (+966) 92 000 Rev.01 for less than 50 km transmission line
6111 Ext 4218 Test Report no. route lengths with the following conditions:
ABPT/368/2012
Jubail dated Oct. 16, 2012 Type Tests:
All type tests for Transmission Line Steel
Contact Person - Mustafa Eltayeb/ Structures (Latticed) up to 380 kV as per latest
Walid Mohamed Eliwa; Mohamed revisions of 20-TMSS-01 shall be carried out for
Munavarudeen the first Contract/Project in the presence of three
Phone - Tel : (+966) +966-920006111 (3) SEC / National Grid SA Engineers and
Email ID - [email protected] approved IIA Inspector.
Contact Person Email ID -
[email protected]; Warranty:
[email protected] Ten (10) years extended warranty from the date
; [email protected] of PAC of the first turnkey project (in case of
Website - www.alfanarsteel.com contract award) or date of first delivery (in case
of direct material supply order) as confirmed,
through their letter No. Nil, dated January 05,
2022, shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

5. 1 Page 214 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MAHMOUD SAEED STEEL INDUSTRIES PQ Letter


CO.LTD. Based on S&SD letter # MPQ5725325 dated April
Saudi Arabia 19, 2021, the manufacturer is prequalified for
fabrication and galvanization of latticed steel
Plant -Jeddah structures for substation Gantries and Equipment
Support Structures Up To 380 kV, as conforming
3rd Industrial Area to National Grid SA specification # 20-TMSS-01,
with the following condition:
Contact Person - Mr. Amr Eid
Phone - +966 12 2880717 Ext.2101 WARRANTY
Email ID - [email protected] ; Ten (10) years extended warranty from the date
Website - www.saeed-steel.com of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter No. Nil dated April 17, 2021
shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

5. 1 Page 215 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KEC Towers LLC Latticed steel structures up to 380 kV PQ Letter:


United Arab Emirates Based on S&SD letter # MPQ9995325-Class I(b)
-2021 dated February 15, 2024, the
Plant -Dubai manufacturer is prequalified for TRANSMISSION
LINE AND SUBSTATION LATTICED STEEL
P.O. Box 452083, Plot No. 597-653, STRUCTURES UP TO 380KV as confirming to
DIP-2 National Grid SA specification # 20-TMSS-01,
with the following conditions:
Sumeet Daga/ Aakash Deep Gupta
[email protected]/guptaad1@kecrpg TYPE TEST CONDITION:
.com All type tests for Transmission Line Steel
+971 56 2160384/+971 56 1998479 Structures (Latticed) up to 380 kV as per the
latest revisions of 20-TMSS-01 shall be carried
Phone - +971 4 8042824/+971 4 out for the first contract/Project in the presence
8042825 of three (3) SEC Engineers and one (1) SEC
Website - www.kecrpg.com approved IIA inspector. All costs of which shall
be borne by KEC TOWERS L.L.C., UAE. This was
confirmed in writing by the manufacturer through
their letter Ref. KEC/TT/CL/001 dated 07th August
2021.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the TRANSMISSION LINE
AND SUBSTATION LATTICED STEEL
STRUCTURES UP TO 380KV in respect of the
defects due to design, manufacturing, installation
and workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # KEC/PQ/WL/001 dated
07.08.2021

Total = 19

POLES, TOWERS, STRUCTURES AND LINE SUPPORTS


5. 2
POLES, STEEL, TAPERED, TUBULAR, FOR TRANSMISSION LINES (UP TO 230KV) Applicable Standards: 20-TMSS-02

5. 2 Page 216 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ENERGYA STEEL SOLUTION (HESHAM PQ Letter


HELAL EL SEWEDY & PARTNERS FOR Based on TS&SD Letter # 10-0331/06-03032301
STEEL INDUSTRIES CO.) dated 28/06/2010, it is pre-qualified for Steel
Saudi Arabia Poles, Tubular up to 230kV as confirming to SEC
specification # 20-TMSS-02. Rev.0 with the
Rabigh – Yanbu High Way Exit 927 following conditions:
Industrial Zone Aramco Road
WARRANTY:
Contact Person - Mr. Ahmed Khan , Mr. Ten (10) years extended warranty/guarantee in
Rayan A. Taj respect of defects due to design, manufacture,
Phone - +966-5609678655 Tel: +966 installation & workmanship from the date of
500150706 ,Fax: +966 500576159 Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] first turnkey project in case of contract award or
Contact Person Email ID - date of first delivery in case of direct material
[email protected], supply order, as confirmed by Hesham Helal EL
[email protected] Sewedy & Partners for Steel Industries Co.
,[email protected] (Energya Steel Solutions) letter #
SEC/WK/100524 dated 24th May 2010.

HIDADA
Saudi Arabia

Plant -Phase 2 Jeddah Industrial City


Jeddah

Po Box 11809 , Jeddah 21463 Saudi


Arabia

Phone - +966- 12-637-4450


Email ID - [email protected]
Website - http://www.hidada.com.sa/

PETIT JEAN
FRANCE

Website - http://www.petitjean.fr/uk/ec
gm.php

5. 2 Page 217 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SUMMIT MANUFACTURING
United States

Pa , United States

Website - http://www.summitmc.com/

TECHNOPALI
ITALY

Website - http://www.technopali.co.uk

VALMONT
United States

Website - http://www.valmont.com/

AL BABTAIN POWER&TELECOM CO
Saudi Arabia

Plant -Riyadh

P O Box: 88373, Riyadh - 11662,

Riyadh

Contact Person - Fawaz Zain


Al-Abedin
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.al-babtain.com.sa

Total = 7

POLES, TOWERS, STRUCTURES AND LINE SUPPORTS


5. 3
PRE ENGINEERED STEEL BUILDING AND SUPPORT STRUCTURES FOR SUBSTATIONS UP TO Applicable Standards: 71-TMSS-03
380 KV S/S

5. 3 Page 218 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Alfanar Steel Pre engineered Structures for PQ Letter


Saudi Arabia buildings, Lattice steel and support Based on S&SD REF.NO MPQ100072235-Class
structure – up to 380 KV I(a)-2021 dated October 23, 2023, the
Plant -Al Jubail Industrial City manufacturer is prequalified for Pre-Engineered
Steel Building And Support Structures For
Jubail industrial area Main Road no. 138 Substations Up To 380 kV S/S as confirming to
Link Road no. 150 National Grid SA specification # 71-TMSS-03,
with the following conditions:
(+966) 56 308 6695; (+966) 92 000
6111 Ext 4218 WARRANTY
Ten (10) years extended warranty/guarantee to
Jubail SEC/National Grid SA for the offered
Pre-Engineered Steel Building And Support
Contact Person - Mustafa Eltayeb/ Structures For Substations Up To 380 kV S/S
Walid Mohamed Eliwa; Mohamed supplies made by Alfanar Steel - Jubail in respect
Munavarudeen of the defects due to design, manufacturing,
Phone - Tel : (+966) +966-920006111 installation and workmanship from the date of
Email ID - [email protected] Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - first turnkey project (in case of contract award)
[email protected]; or from the date of first delivery (in case of
[email protected] direct material supply order), as confirmed by the
; [email protected] manufacturer, through their Letter Ref. # Nil dated
Website - www.alfanarsteel.com 02nd September, 2021

5. 3 Page 219 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Kirby Building Systems Kirby Building Systems Design, Fabricate and Supply of Pre PQ Letter
Kuwait 7477 Prince Muhammed Engineered Steel Buildings and Based on S&SD REF.NO MPQ99312235-Class
Bin Fahd Rd- Structural Steel Up To 380 kV S/S I(b)-2021 dated August 23, 2023, the
Plant -Kuwait AlMazruiyah Dist.Unit manufacturer is prequalified for Pre-Engineered
No(2209)- Dammam Steel Building And Support Structures For
Mina Abdullah Industrial Area P.O.Box 32414-4171-KSA Substations Up To 380 kV S/S as confirming to
23933 Safat Main Street Kuwait +966 505867387 National Grid SA specification # 71-TMSS-03,
[email protected] with the following conditions:
Contact Person - Eng. Ahmed Al Nufaily m
Phone - +96523262800 WARRANTY
Email ID - [email protected] Ten (10) years extended warranty/guarantee to
Contact Person Email ID - SEC/National Grid SA for the offered
[email protected] Pre-Engineered Steel Building And Support
Website - www.kirbyinternational.com Structures For Substations Up To 380 kV S/S
supplies made by Kirby Building Systems –
Kuwait in respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # Nil dated 16th July, 2023

Total = 2

CONDUITS, FITTINGS & ACCESSSORIES


6. 1
DUCT SEALING UNITS Applicable Standards: 23-TMSS-02

6. 1 Page 220 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TECHNO RUBBER COMPANY LTD Duct Sealing Units Type Tests PQ Letter
Saudi Arabia successfully
completed at Al-Hoty Based on S&SD letter # MPQ1111346-Class 1 (a)
Plant -Saudi Arabia Laboratories – -2016-I(b)dated October 29, 2019, the
Dammam, KSA (4 manufacturer is prequalified for Duct Sealing
Dammam, Saudi Arabia July 2019), Bureau Units as confirming to National Grid SA
2ND INDUSTRIAL CITY Veritas Report No. specification # 23-TMSS-02, with the following
12/4072019-01 & conditions:
P.O.BOX 3508 DAMMAM 34326 12/19022018-01
dated 15.7.2019 WARRANTY
Dammam
Ten (10) years extended warranty from the date
Contact Person - Mr. Rajashekaran / of PAC of the first turnkey project (in case of
Mr.Chand Mubarak contract award) or date of first delivery (in case
Phone - +966 13 812 3333 Ext.-215 of direct material supply order), as confirmed,
Email ID - [email protected] through their Letter #Nil dated May 24, 2017, shall
Contact Person Email ID - be applicable for the equipment to be supplied to
[email protected] / SEC/National Grid SA.
[email protected]
Website - www.technorubber.com.sa

AMIANTIT RUBBER IND. (ARIL)


Saudi Arabia

Dammam , Saudi Arabia

Website -
http://www.amiantit.com/en/default.php

UM- AL QUWAIN RUBBER INDUSTRIES


United Arab Emirates

Total = 3

CONDUITS, FITTINGS & ACCESSSORIES


6. 2
Cable clamps for Power Cables (Up to 380 kV) Applicable Standards: 23-TMSS-04

6. 2 Page 221 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

POWER TRANSMISSION AND Cable Clamps for Power Cables up to CPRI ( Central PQ Letter:
TELECOMMUNICATION EQUIPMENTS 380 kV Power Research Based on S&SD letter # 18-04057-01-30504401
FACTORY (P.T.E. CO.) (CEPCO) Institute ) Report # dated November 11, 2018, Power Transmission
Saudi Arabia CPRIBLRHPL1819T0 and Telecommunication Equipment Factory Co. -
104 dated 16.7.2018 (P.T.E. ..Co.), Jeddah, Saudi Arabia is
Jeddah Industrial City : P.O Box 8234 and Report # pre-qualified for Cable Clamps up to 380kV as
Jeddah 21482 CPRIBLRMEDMISC18 conforming to National Grid SA specification #
19T0014 dated 23-TMSS-04, with the following condition:
Plant: Plot No. 1&2, Al-Mahjar Street, 13.7.2018 for Flat
Industrial Clamps Warranty:
Ten (10) years extended warranty/guaranty
Contact Person - Eng. Mohammad CPRI ( Central from the date of (PAC) of the Turnkey project (In
Saleem Mir (General Manager); Mr. Power Research case of contract award) and from the date of
Faisal Jandali Institute ) Report # delivery for the direct material supply order. The
Phone - +966 1260 95165; +966 595 CPRIBLRHPL1819T0 guarantee/warranty shall be applicable from first
3323 74; +966126608629; 107 dated 16.7.2018 project and shall cover all the cost of materials
+966504661072 and Report # and labor as per warranty/guarantee of materials
Email ID - [email protected] CPRIBLRMEDMISC18 and workmanship and subsequently reduced
Website - www.pte-sa.com 19T0014c dated yearly in case of future project award. This was
13.7.2018 for Trefoil confirmed in writing by Power Transmission and
Clamps Telecommunication Equipment Factory Co. -
(P.T.E. ..Co.), Jeddah, Saudi Arabia through their
SGS Inspection letter # PTE/PQ/Clamps/2016/L-097R1 dated #
Report # August 13, 2018.
BRD/GHV/34/2018

6. 2 Page 222 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Abdullah Mohammed Hassan Type tests in PQ Letter


Al-Shahrani Factory CPRI-Bangalore, Based on S&SD letter# MPQ34961856-Class I(b)
Saudi Arabia India Laboratory and -2018 dated June 29, 2020, the manufacturer is
witness by prequalified for Cable clamps for Power Cables
Plant -Riyadh SEC/National Grid as confirming to SEC specification # 23-TMSS-04,
SA approved third with the following conditions:
P.O. Box 86820 Near Ice Cone Zone party inspector.
183 Riyadh Saudi Arabia. CPRI Bangalore India WARRANTY
Type Test Report # Ten (10) years extended warranty in respect of
Contact Person - Mr. MOHAMMAD CPRIBLRHPLMISC19 the defects due to design, manufacturing,
ABDUL SAMAD , Operation and Sales T0275 Dated 14.5.20 installation and workmanship from the date of the
Phone - 00966 11 2653414 SGS Report # Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected]; VRT/MUM/2020/23 first project (in case of contract award) and from
[email protected] Dated 23.1.20 the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter
#SEC/ASF/CC/004-R2/2020 dated June 24, 2020.

Total = 2

CONDUITS, FITTINGS & ACCESSSORIES


6. 3
PVC Conduits & Fittings for Underground Cables Applicable Standards: 23-TMSS-01

6. 3 Page 223 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

B.C for Manufacturing Plastic Electrical Type DB, EB, and EPC-40 PVC Pipes Type Test Report # PQ Letter
Conduits JPQ22000022 (
Saudi Arabia Tested on March 29, Based on S&SD letter # MPQ12271964-Class
30, 31, 2022, May IV(b)- 2017 dated September 27, 2022, the
Plant -Bahra 28, 2022 & June 28 , manufacturer is prequalified for PVC Conduits &
2022 at ACES Fittings for UG Cables under as confirming to
Bahra – CPC industry area LABORATORY – National Grid SA specification # 23-TMSS-01,
JEDDAH, SAUDI with the following conditions:
Jeddah ARABIA)

Contact Person - Loai Taha WARRANTY


Albar/Abdullah Abdulwahab Rawah/
Karim Ahmed M Nour Ten (10) years extended warranty from the date
Phone - 012-5111159 Ext. 1050 /1040/ of PAC of the first turnkey project (in case of
5680 contract award) or date of first delivery (in case
Contact Person Email ID - of direct material supply order), as confirmed,
[email protected] / through their Letter #17042017/BC dated April 17,
[email protected] / 2017, shall be applicable for the equipment to be
[email protected] supplied to SEC/National Grid SA.
Website - www.bahra-electric.com

ISAM M. KHAIRY KABBANI & National Marketing Est. Type DB, EB, and EPC-40-PVC Type tests PQ Letter:
INSULATION FACTORY COMPANY Co. Ltd. Conduits (NAMCODUCT) conducted at ACES Based on S&SD letter #MPQ4561946-Class IV(b)
Saudi Arabia P. O. Box 16375, Jeddah (Arab Company for -2018_Class I(b) dated April 05, 2022, ISAM M.
21464. Kingdom of Saudi Laboratories & Soil), KHAIRY KABBANI & INSULATION FACTORY
Plant -Dammam 2nd industrial City Arabia. Jeddah, Saudi COMPANY – is pre-qualified for PVC Conduits
0 50 365 1754 Arabia dated August and Fittings for underground Cables as
Street No 95, 7202- Unit No. 3520, Ad [email protected] 19, August 21, conforming to National Grid SA specification
Dammam 34332-2770 m October 19 and 23-TMSS-01, Rev.01, with the following
November 17, 2021 conditions:
Dammam
WARRANTY:
Contact Person - MR. Omar Al-Sasa, Ten (10) year Extended Warranty as confirmed,
Mr. Mahmoud Awwad/ through letter # Nil, dated 06/03/2022 shall be
Phone - +966 138342544,+966 13 892 applicable for all supplies made by M/S ISAM M.
3543 KHAIRY KABBANI & INSULATION FACTORY
Email ID - COMPANY, DAMMAM, KSA
[email protected]
Contact Person Email ID -
[email protected],
[email protected]
Website - www.ikkgroup.com

6. 3 Page 224 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 2

CONDUITS, FITTINGS & ACCESSSORIES


6. 4
Underground Cable Trench Materials Applicable Standards: 70-TMSS-04

AL SAMIR PLASTIC FACTORY LLC Power Lines Contracting PQ letter:


United Arab Emirates Wasel 3164, Riyadh Based on S&SD letter # 18-00229/01-30504401,
12471-6203 dated January, 28 2018, for Al-Samir Plastic
Plant -SHARJAH 0112692142 Factory LLC, Sharjah, UAE is pre-qualified for
[email protected] Polyethylene Cable Protection Tiles for
INDUSTRIAL AREA # 6, P.O. Box: 22820 Underground buried cables as conforming to
National Grid SA with specification # 70-TMSS-04
Contact Person - MR, OSAMA AL Rev.1 with the following conditions:
MASRI
Phone - +9716-65420254/ 9716-542 0 WARRANTY:
254 Ten (10) years extended warranty from the date
Email ID - [email protected] of PAC of the project (in case of contract award)
/[email protected] or date of delivery (in case of direct material
Website - www.alsamirplast.com supply order), as confirmed to SEC/National Grid
SA, through their Letter No # Nil, dated June 01,
2015.

Total = 1

WIRE WAYS, CABLE TRAYS, BOXES AND ENCLOSURES


7. 1
METALLIC CABLE TRAY SYSTEMS Applicable Standards: 24-TMSS-01

7. 1 Page 225 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALASHHOURY INDUSTRY PQ Letter


Saudi Arabia Based on TS&SD letter # 11-0036/04-03032301
dated 06/06/2011 prequalified for Cable Trays &
Riyadh, Saudi Arabia Cable Ladders.

For any new design of Cable Trays or Cable


Ladders proposed by Al-Ashouri Industries
(other than the test proven SEC designs), Type,
Special, routine and Sample test as per the SEC
standards/Specification shall be conduct on the
first batch to be supplied to SEC in presence of
three (03) SEC Engineers in an SEC approved
independent test laboratory

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by Al-Ashouri
Industries through letter # 2010/4-03/0003 dated
01/08/2010.

Legrand Saudi Electric Industries Co. ON HOLD


Ltd.
Saudi Arabia
Note:
Jeddah , Saudi Arabia Previously " Saudi Electric Industries Company
Ltd. (SEICO) ", the name has been changed to "
Jeddah Legrand Saudi Electric Industries Company Ltd".
based on their letter # Nil dated October 30,
Contact Person - Muhammad Anwar Ul 2017.
Haq (Business Development Manager)
Contact Person Email ID -
muhammad.anwarulhaq@legrand-seic
o.sa
Website -
http://www.legrand-seico.sa/

7. 1 Page 226 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

3M
United States

Website - http://solutions.3m.com/en
US/

AB WIRE
SWEDEN

Website - http://www.moorlink.com/

ABAHSAIN-COPE
Saudi Arabia

Dhahran , Saudi Arabia

Website -
http://www.abahsain.net/Abcope.htm

AL-AMAL CO. Type / Model: FOR LADDERS & Type Tests FOR LADDERS & ACCESSORIES
Saudi Arabia ACCESSORIES conducted in King
Saud University on WARRANTY:
Riyadh, Saudi Arabia 14th July, 2008 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order as confirmed by the manufacturer
vide their letter no. IMD-CR-955, dt: October 29th,
2007.

7. 1 Page 227 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AL-MISBAH HOUSE FOR STEEL Type / Model: Metallic Cable Tray PQ Letter
WORKS Systems Based on TS&SD letter 09-00509/1-03032301
Saudi Arabia dated 16th. March 2009 for Metallic Cable Tray
Rating: Systems.
Riyadh , Saudi Arabia
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

EFCOR
United States

ELECTROLINK CO. LTD. Electrolink Company Type / Model: Metallic Cable Tray PQ Letter
Saudi Arabia Limited Systems Based on TS&SD letter 09-00524/1-03032301
dated 16th. March 2009 for Metallic Cable Tray
Plant -2nd Industrial Area, Riyadh City Rating: Systems.

PO Box 771, Street # 155, 2nd WARRANTY:


Industrial Area, Riyadh 11312 Eight (8) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Riyadh installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Numan Nisar Raja first turnkey project in case of contract award or
(Sales Manager), Abid Siraj (Sales date of first delivery in case of direct material
Coordinator) supply order as confirmed by the manufacturer
Phone - +966 11 265 5473 through their letter no.nil, dt: 2nd Aug, 2008.
Contact Person Email ID -
([email protected]),
([email protected])
Website - http://hig-sa.com/ecl.php

7. 1 Page 228 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FAS AL-JAZEERA Type test conducted PQ Letter


Saudi Arabia in independent Based on S&SD letter # 15-00242/01-30504401
testing lab , Al-Hoty dated March 19 2015, the manufacturer is
Dammam, Saudi Arabia Calibration Services prequalified for ‘Cable trays, Cable Ladders and
during 28th to 30th Accessories’ as conforming to National Grid SA
Dec 2014. specification # 24-TMSS-01, Rev.01 with the
Test Report NO. following conditions:
4786159732.1.1 For new designs of cable trays or cable ladders
proposed by FAS Al Jazeera (other than the test
proven SEC/National Grid SA designs), All type,
special, routine tests shall be conducted on the
first batch to be supplied to SEC/National Grid SA,
in the presence of three (3) SEC/National Grid SA
engineers at SEC/National Grid SA approved
independent testing laboratory

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 2nd Dec, 2012.

HIDADA
Saudi Arabia

Website - http://www.hidada.com.sa/

MECSS - MID EAST CABLE SUPPORT


SOLUTIONS
Saudi Arabia

Al-Khobar , Saudi Arabia

Website -
http://mecss.com.sa/contact.html

7. 1 Page 229 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

O-Z GEDNEY
United States

Website - http://www.o-zgedney.com/

SPECIALIZED FACTORY FOR STEEL Type tested at KSU PQ Letter


PRODUCTS (SFSP) Riyadh, Al-Futtaim Based on S&SD Letter # 15-01409-01-30504401,
Saudi Arabia Exova, Dubai & at dated 18th March 2015 the manufacturer is
Al-Hoty Calibration prequalified for Cable trays, Cable Ladders and
Plant -Industrial Ara Phase-3 Services Al Khobar Accessories as conforming to National Grid SA
on 7th January Material Specification 24-TMSS-01, Rev.01, with
Po Box 50533 Jeddah 21533 Saudi 2015. the following conditions:
Arabia For any new design of cable trays or cable
ladders proposed by Specialized Factory for
Contact Person - Mr. Waleed Al-Aseeri Steel Products (SFSP) (other than the test proven
Phone - +966-2-637-4482 SEC/National Grid SA designs), Type, Special,
Email ID - routine and Sample test as per the SEC/ National
[email protected],Unimetal.riya Grid SA
[email protected],Yusuf.reda@ikkgrou standards/ Specification shall be conducted on
p.com the first batch to be supplied to SEC/ National Grid
Website - http://www.sfsp.ikk.com SA in presence of three (03) SEC/ National Grid
SA Engineers in an SEC National Grid SA
approved independent test laboratory

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #NIL, DT: 15th Jan, 2013.

TOLARTOIS
FRANCE

Website -
http://www.tole-perforee.com

7. 1 Page 230 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ARABIAN INTERNATIONAL CO.


Saudi Arabia

Jeddah , Saudi Arabia

Email ID - [email protected].
Website - http://www.aicsteel.com/

WESCOSA
Saudi Arabia

Plant -Dammam , Saudi Arabia

First Industrial City of Dammam, P.O.


Box 2389, Dammam 31451, Saudi
Arabia

Contact Person - +966500594704


Phone - +966138100234 Ext 3267
Email ID - [email protected] ,
[email protected]
Website - http://www.wescosa.com/

7. 1 Page 231 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB Electrical Industries Company Ltd Test conducted at Note:


Saudi Arabia Al-hoty Stanger Previously " Thomas & Betts ", the name has
Laboratories been changed to "
Plant -Dammam, Saudi Arabia Khobar, KSA. Test ABB Electrical Industries Company Ltd ". based
Report # 50358-1. on their letter # TNB/DAMM/SECTD/009 dated
Mecca Road 67 Cross 8 - st. 75 / 77, February 15,
Dammam Industrial City– Dammam, 2018.
Saudi Arabia

P.O. Box 514 Al-Khobar 31952 PQ letter:


Based on S&SD letter # 17-08226-02-30504401
Dammam dated January 10, 2018, ABB Electrical Industries
Company Ltd, Saudi Arabia is pre-qualified for
Contact Person - Ahmed Hussain Aluminum & Galvanized Cable Trays and Ladders
Phone - +966 (0) 13 8121222 as conforming to latest National Grid SA
Email ID - [email protected] specification # 24-TMSS-01Rev.01 with the
, following conditions:
Contact Person Email ID -
[email protected] WARRANTY:
Website - www.abb.com Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated April 26, 2016.

7. 1 Page 232 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Power Solution Industries (PSI) Test conducted at Al PQ Letter:


Saudi Arabia hoty Stanger Based on S&SD letter # 17-07120-02-30504401
Laboratories Dubai, dated January 10, 2018 Power Solution
Plant -Riyadh, KSA UAE. Test Report # Industries - Riyadh, KSA is pre-qualified for Cable
EF 17055. Support Systems (Cable Trays, Cable Ladders,
Obeikan Industrial City, Industrial Cable Trunking, Strut Metal Framing Etc.) as
Area-2, New Al Kharj Road conforming to latest National Grid SA
specification # 24-TMSS-01, Rev.01 with the
Riyadh following conditions:

Contact Person - Amr El Zahed WARRANTY:


Phone - 00966-112422511 Ten (10) years extended warranty/guarantee in
Email ID - [email protected] respect of defects due to design, manufacture,
Contact Person Email ID - installation and workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
Website - www.powersolutionme.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated March 26, 2015.

Ba’amer Electric Factory Galvanized Carbon Steel Cable Trays Type Test PQ letter:
Saudi Arabia and Ladders Report/Inspection Based on S&SD letter # 18-01054/01-030504401
Certificate # dated April 24, 2018, for Ba`Amer Electric
Plant -Jeddah, 2nd Industrial City R/013/SA/RYD/18 Factory Jeddah, KSA is pre-qualified for Cable
dated 10.2.2018 Support Systems (Cable Trays, Cable Ladders,
P.O. Box 30066 Jeddah 21477 conducted at Cable Trunking, Strut Metal Framing Etc.) as
Al-Hoty Calibration conforming to latest National Grid SA
Jeddah Services Khobar specification # 24-TMSS-01, Rev.01 with the
KSA following conditions:
Contact Person - Engr. Mohammad
Al-Shareef WARRANTY:
Phone - 012 6610 260 - 012 608 1999 Ten (10) years extended warranty/guarantee in
Email ID - [email protected] respect of defects due to design, manufacture,
Contact Person Email ID - installation and workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
Website - www.baamerelectric.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated April 05, 2018.

7. 1 Page 233 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KHEREIJI SHOWROOMS COMPANY Cable Trays & Cable Ladders Steel Test conducted at Al PQ Letter
Saudi Arabia HDG. Hoty Lab, Dammam, Based on S&SD letter #MPQ9967357-Class I(b)
Cable Trays & Cable Ladders KSA. Test Report # -2021 dated March 16, 2023, the manufacturer is
Plant -Al Fozan Industrial Area, Sulay Aluminium IR -258129877-100 prequalified for METALLIC CABLE TRAY
Dist. Dated: 28-Jan-2023 SYSTEMS as confirming to National Grid SA
specification #24-TMSS-01, with the following
Al Fozan Industrial Area, Sulay Dist. conditions:
P.O. BOX 27312 RIYADH 11417
WARRANTY
RIYADH Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered METALLIC
Contact Person - Mohammed Emara, CABLE TRAY SYSTEMS in respect of the defects
Tamer Fathi & Abdullah Shaban due to design, manufacturing, installation and
Phone - +966 1 242 8324 EXT:233 workmanship from the date of Provisional
Email ID - [email protected] Acceptance Certificate (PAC) of the first turnkey
Contact Person Email ID - project (in case of contract award) or from the
[email protected] , date of first delivery (in case of direct material
[email protected] & supply order), as confirmed by the manufacturer,
[email protected] through their Letter Ref. # Nil, dated May 30,
Website - www.ksc.com.sa 2022.

DAR METAL INDUSTRIES COMPANY Cable Trays and Ladder ( HDG Steel Type Test PQ Letter
Saudi Arabia and Aluminum) performed in AL
HOTY LAB – Al Based on S&SD letter # MPQ9960357-Class I(b)
Plant -AlKharj Khobar, KSA on -2021 dated January 01, 2024, the manufacturer
November 7, 8, 9 & is prequalified for METALLIC CABLE TRAY
Dar Metal Industries - Modon Industrial 13 2023 with AICO SYSTEMS as confirming to National Grid SA
city street No. 14 14 Al-Kharj - Saudi Test report: DAR specification #24-TMSS-01, with the following
Arabia Metal/Al-Hoty/01 conditions:

Contact Person - Eng. Baraa Ismail


Alamro, Eng. Nabeel Shoshara, WARRANTY
Phone - 920000242 - (+966)
112421401 Ten (10) years extended warranty from the date
Email ID - [email protected] of PAC of the first turnkey project (in case of
Contact Person Email ID - contract award) or date of first delivery (in case
[email protected], +966 555 of direct material supply order), as confirmed,
186 283, [email protected], through their Letter #Nil dated May 18, 2021, shall
+966593444707 be applicable for the equipment to be supplied to
Website - darmetal.com.sa SEC/National Grid SA.

Total = 22

7. 1 Page 234 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LINE SWITCHES AND DISCONNECTING DEVICES


8. 1
AIR BREAK DISCONNECT SWITCHES AND GROUNDING SWITCHES, 33KV THROUGH 380KV Applicable Standards: 30-TMSS-01

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

S&C
United States

Website - http://www.sandc.com/

SOUTHERN STATES SOUTHERN STATES/ USA HAS ACQUIRED


United States SIEMENS SWITCH FACTORY

Website -
http://www.southernstates.com/

ALPHA NIDAU
SWITZERLAND

8. 1 Page 235 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE Grid Solutions S. P .A Type / Model: Disconnect switch; PQ Letter:


ITALY S3CD, S3CDT & S3CD2T) and S&SD letter# 13-04035-02-30504401 dated July
Standalone Grounding Switches (STB) 22, 2013, for disconnect switches 420kV, 4000 A
Venice, Noventa Di Piave , Italy (S3CD, S3CDT & S3CD2T) only and Standalone
Rating: 420kV, 4000A, 63kA Grounding Switches (STB)

CONDITION:
All type/special and routine tests for Disconnect
Switches 420kV, 4000A (S3CD, S3CDT &
S3CD2T) only and Standalone Grounding
Switches (STB) 420kV, 63kA only shall be
conducted at in an Independent testing laboratory
on one switch before supplied to SEC system in
the presence of three (3) SEC/National Grid SA
engineers & one (1) National Grid SA approved
independent inspection agency Inspector, all the
related costs for witnessing the tests will be
borne by the manufacturer. This was confirmed
by Alstom Grid S. p .A, ITALY through their letter
# 323/11/C/RP.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #136/11/CO/RP.

EFACEC
PORTUGAL

Contact Person - Mr. Abílio Rodrigues


Phone - +351 968331386; +351
229562300
Email ID - [email protected];
[email protected];
Website -
http://www.efacec.pt/en/switchgear/

8. 1 Page 236 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HAPAM Suspended, based on TS&SD letter


NETHERLANDS 10-00402-03032301, dated February 08, 2010.

Website - http://www.hapam.nl/

MG/EGIC
FRANCE

SDCEM SUSPENDED for all SEC/National Grid SA


FRANCE ongoing and forthcoming projects based on VP,
Engineering letter # 17-01852-30504401 dated
Website - http://www.sdcem.com/ March 05, 2017.

SIEMENS
GERMANY

Website - http://
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx

AREVA
FRANCE

Plant -France

Website - http://www.areva.com/

HITACHI LTD Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

Total = 12

8. 1 Page 237 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SUBSTATION PANELS
9. 1
RELAY & CONTROL PANEL Applicable Standards: 31-TMSS-01

JAL INTERNATIONAL Upto 380kV Based on S&SD letter# 16-05501-30504401


Saudi Arabia dated August 17, 2016, the manufacturer is
prequalified for Relay and Control Panels as
Khobar , Saudi Arabia confirming to SEC specification # 31-TMSS-01,
with the following condition:
Contact Person - Mr. Muhammad Sajjad
Manzoor. Sales Manager (A) • Ten (10) years extended warranty from the
Contact Person Email ID - date of PAC of the turnkey project in case of
[email protected] contract award and date of delivery in case of
Website - direct material supply order, as confirmed by the
http://www.jalinternational.com.sa/V2/j manufacturer through letter #JAL/ED/C&R-PQ/13
al/ dated December 22, 2015

ABB S.R.O (RFF) ABB Automation Co. Ltd. Type tested in PQ Lettter
CZECH REPUBLIC PO Box.414 Riyadh Independent Lab Based on S&SD letter# 15-09012-1-30504401
11383 EZU Parague, Czech dated November 05, 2015, it is pre-qualified for
Stetkova 1638/18,140 00 Praha 4Czech republic/EVPU Nova Relay & Control Panels as conforming to National
Republic-Trutnov Dubnica, Slovakia on Grid SA specification # 31-TMSS-01, with the
5th to 15th may following condition:
Contact Person - Mr. Essam 2015
Bashraheel & Mr Aref Al-Arrak Report#08.220.985. WARRANTY
Email ID - Ten (10) year Extended Warranty as confirmed
[email protected] through
&[email protected] their Letter No. 14-05231-01-30504401 dated
November 10,
2014 shall be applicable for all supplies by ABB
s.r.o (RFF), Trutnov-Czech Republic.

9. 1 Page 238 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Switzerland AB ABB Automation Co. Ltd. Type tested in Mfr. Name change from ABB SWITZERLAND LTD
SWITZERLAND Hitachi Energy Ltd. Independent Lab to Hitachi Energy Sweden AB
Riyadh, Saudi Arabia EZU Parague, Czech
Bruggerstrasse 72, 5400 Baden Republic /EVPU
Nova Dubnica, PQ Lettter
Contact Person - Mr. Ahmed Abubasha, Slovakia on 5th to Based on S&SD letter# 15-09013-1-30504401
Mr. Abdulmajeed Alothman 15th may 2015 dated November 05, 2015, it is pre-qualified for
Email ID - Relay & Control Panels, as conforming to National
[email protected] , Report#08.220.986. Grid SA specification # 31-TMSS-01 with the
[email protected] following condition:
om
Contact Person Email ID - WARRANTY
[email protected] , Ten (10) years Extended Warranty as confirmed
[email protected] through
om their Letter #14-05230-01-30504401 NIL dated
Website - www.hitachienergy.com 4th November 2014 shall be applicable for all
supplies made by ABB Switzerland Ltd -
Switzerland.

ACRASTYLE
United Kingdom

Website - http://www.acrastyle.co.uk/

AEL –SIEMENS SIEMENS Ltd IC SG EA Rating:Relay and control panel up to


Saudi Arabia SYS 380kV
CONTACT PERSON:
Plant -Jeddah , Saudi Arabia Gani. Saleem,
Jeddah,21412, Baladiyah
Siemens Factory - Jeddah Modon Street, P.O. Box 4621
Oasis Industrial Zone - Asfan Road Phone: +966 (12)
661-8966
Jeddah [email protected]
om
Contact Person - Aslam Jameel
Phone - +966 (12) 661-8972 ; +966 56
790 6195
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.siemens.com.sa/cms/sa/ho
me/Pages/Default.aspx

9. 1 Page 239 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CRUINKSHANK & PARTNERS LTD.


United Kingdom

Website -
http://www.kerrcruickshank.com/

ELECTRICAL RELAYS FACTORY CO. Type test were PQ Letter


(ERFC) conducted at KSU Based on S&SD letter# 15-09095-030504401
Saudi Arabia on 12th October dated November 09, 2015, it is pre-qualified for
2015 in the Relay & Control Panels, as conforming to National
Po Box 101709 Riyadh 11665 presence of SGS Grid SA specification # 31-TMSS-01 with the
3rd party Inspectors following condition:
Contact Person - Mr. Talal M. Al-Huribi and SEC/ National
ERFC General Manager Grid SA engineers. WARRANTY:
Phone - +966-11-498-6479 Type Test Ten (10) years extended warranty/guarantee in
Email ID - Report#SGS/DAM/M respect of defects due to design, manufacture,
[email protected] -15/778 installation & workmanship from the date of
Website - Provisional Acceptance Certificate (PAC) of the
http://www.erelaysgroup.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru Letter # NIL dated 30th August 2014.

AG PCS SWITCHGEAR It is pre-qualified for Relay & Control Panels as


MANUFACTURING L.L.C conforming to SEC specification # 31-TMSS-01,
United Arab Emirates Rev.0 with the following condition:

Plant -Ajman /U.A.E WARRANTY


Ten (10) years extended warranty/guarantee in
U.A.E P.O.Box - 5239 Dubai , United respect of defects due to design, manufacture,
Arab Emirates installation & workmanship from the date of PAC
of the turnkey project in case of contract award
Contact Person - Mr. Zia ul haq or date of delivery in case of direct material
GENERAL MANAGER supply order.
Phone - +971 55 300 35 36
Email ID - [email protected] Enclosures are manufactured in STAR
Contact Person Email ID - ELEVATOR SYSTEM & METAL TECHNOLOGY
[email protected] LLC (former ETA-PCS) Dubai .
Website - http://www.etapcs.com/

9. 1 Page 240 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR ELEKTRICNI UREDAJI D.D Nesma Telecom& Rating - upto 380 kv PQ Lettter
CROATIA Technology Co. Ltd. Based on S&SD letter# 14-1456-03-30504401
Jeddah Asfan Road dated April 15, 2014, it is pre-qualified for Relay &
Plant -Zagreb/Croatia - Hrvatska inside azzam compound Control Panel up to 380 kV as conforming to
Tel:012-2727637,Phone - National Grid SA specification # 31-TMSS-01,
Končar-Električni Uređaji D.D. Prisoje 0500000582 with the following condition:
29A, 21232, Dicmo, Hr Email - WARRANTY
[email protected] Ten (10) years extended warranty/guarantee in
Contact Person - Mr. Ljubomir Zubčić, om respect of defects due to design, manufacture,
Phone - +385 21 778 512; +385 91 374 installation & workmanship from the date of
2009 ; +385 021 778 516 Provisional Acceptance Certificate (PAC) of the
Email ID - Email first turnkey project in case of contract award or
:[email protected] date of first delivery in case of direct material
Website - Web: supply order.
http://www.koncareu.hr

LS, Innovative Systems PREVIOUSLY LG


KOREA, Republic of (ISys),
CONTACT PERSON:
Plant - Korea, , Republic Of Cheongju Kamal Al Muhanna, P O
Box 60606,
13F Ls Tower, 127, Ls-Ro, Dongan-Gu, Riyadh-11555
Anyang-Si, Gyeonggi-Do, Korea Phone: +966 11 460
8161
Contact Person - Mr. Jiyup Balk E-mail: [email protected]
Phone - +82 54 469 7602
Website - http://www.lscable.com/

9. 1 Page 241 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

META Switchgear a branch of MEMF Rating: up to 132kV PQ Lettter


Electrical Industries Co Based on S&SD Letter 13-03789-03-30504401
Saudi Arabia dated January 28, 2013. It is prequalified for
Relay & Control Panel up to 132kV as conforming
Plant -Riyadh , Saudi Arabia (Branch Of to National Grid SA specification # 31-TMSS-01,
Memf Electrical Industries Co.) Rev.0, with the following condition:

P.O. 6189, 2nd industrial city Al-Kharj WARRANTY


road Riyadh Saudi Arabia Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Riyadh installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. Fahad Alharkan first turnkey project in case of contract award or
/MEMF, Nasser Alenezy / MEMF date of first delivery in case of direct material
Phone - +966 11 4966667 Ext.119 supply order, as confirmed by the manufacturer
Email ID - thru letter #META/12/AM, dt: Mar 23, 2011.
[email protected],
[email protected] Previously MEMF-ETA Switchgear Manufacturing
Contact Person Email ID - Company, Riyadh, Saudi Arabia [The name has
[email protected] been changed based on P&SFD letter #
Website - www.kfbgroup.com.sa 15-10879-30504401 dated December 23, 2015].

MOHD. AL-OJAIMI LTD, SAUDI ARABIA WARRANTY


Saudi Arabia Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Plant -Riyadh , Saudi Arabia installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Website - http://www.alojaimi.com/Our first turnkey project in case of contract award or
Companies/Introduction - Mohammed date of delivery in case of direct material supply
Al-Oja/introduction - mohammed order.
al-oja.html

9. 1 Page 242 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PROTEA/AREVA T&D PQ Lettter


FRANCE Based on TS&SD Letter # 08-02176-03032301,
dt:20th Aug, 2008 for Relay & Control Panel as
Website - conforming to National Grid SA specification #
http://www.protea-pierrelatte.com 31-TMSS-01, Rev.0, with the following condition:

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.nil, dt: 18th July, 2008.

REYROLLE LTD.
United Kingdom

Website -
http://www.reyrolle-protection.com/

SCHNEIDER H.V FACTORY


FRANCE

Grenoble France

SIEMENS ,GERMANY Siemens Ltd IC SG EA Type/Model - Protection , control and


GERMANY Pro Automation Devices
Contact Person:Mr. Rating - 380 kV-13.8 kV
Plant -Berlin Germany Khaleel Al-Adani,Jeddah
21412 Baladiyah Street
Ic Sg Ea Mf, Wernerwekdamm 5 13629, PO Box 4621
Berlin Germany Contact Person: Phone -
+966-12-6618831
Contact Person - Mr. Hartmut. Von Email -
Zandeer khaleel.al-adani@siemen
Phone - +49(30)386-26688 s.com
Email ID - Hartmut.von
[email protected]
Website -
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

9. 1 Page 243 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SYSTEM HOUSE FACTORY FOR Rating: PQ Lettter


ELECTRIC PANELS (SEP,) Relay and control panel up to 380kV Based on TS&SD letter# 09-01500-03032301
Saudi Arabia dated May 25, 2009, 10-01055/02-03032301
dated May 03, 2010 & S&SD Letter
Plant -New Industrial Area No:1, Riyadh 12-03596-02-30504401 dated April 29, 2012. It is
prequalified for Relay & Control Panel up to
P O Box 355950, New Industrial Area 380kV as conforming to SEC specification #
No:2, Riyadh -11383 31-TMSS-01, with the following condition:

Contact Person - Mr. Bruno Stocchi, WARRANTY


Muhannad Alshehri Ten (10) years extended warranty/guarantee in
Phone - +966- 0535754302 , +966- respect of defects due to design, manufacture,
0505278491 installation & workmanship from the date of
Email ID - E-mail [email protected], Provisional Acceptance Certificate (PAC) of the
[email protected] Aburajab, first turnkey project in case of contract award or
Contact Person Email ID - date of first delivery in case of direct material
[email protected] supply order, as confirmed by the manufacturer
thru letter #nil, dt: Dec 11, 2012.

9. 1 Page 244 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GRID SOLUTION ARABIA LIMITED PQ Letter


Saudi Arabia Based on S&SD letter # 14-04579-2-030504401,
dated 30/06/2014, it is prequalified for Integration
Plant -Alkhobar , Saudi Arabia & Testing of Relay & Control Panels confirming to
National Grid SA Material Specification
Saudi Arabia 31-TMSS-01, Rev.0, with the following
conditions:-

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #NIL, DT: 03/10/2013.

Previously ALSTOM GRID INTEGRATION &


TESTING FACILITY, SAUDI ARABIA, the name has
been changed to GRID SOLUTION ARABIA
LIMITED - SAUDI ARABIA based on their letter #
Nil, dated October 06, 2019.

TIEPCO
Saudi Arabia

Plant -Tiepco Factory Die-Ii Dammam


Saudi Arabia,

Post Box 2705 Dammam Saudi Arabia,


Dammam , Saudi Arabia

Contact Person - Mr. Aamar Saeed GM


Sales
Phone - +966-6380080
Email ID - [email protected]
Website - http://www.tiepco.com

9. 1 Page 245 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

VA TECH Rating up to 132kV ASSEMBLING UP TO 132KV ONLY,


Saudi Arabia ENCLOSURES SHALL BE PROCURED FROM
MESCO (RIYADH)
Riyadh , Saudi Arabia

EPS LTD. (GROUPE SCHNEIDER) Rating: up to 380kV


Saudi Arabia

Po Box 89249, 2Nd Industrial City


Riyadh - 11682, Saudi Arabia

Contact Person - Mr.Mr. Ahmed


Majrashi Mr. Bhaskar Sahu
Phone - +966-551304199
Email ID -
[email protected]
m
Website -
http://www.schneider-electric.com.sa

9. 1 Page 246 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

WESCOSA Rating: up to 380kV PQ Lettter


Saudi Arabia Based on TS&SD letter # 11-F02715-03032301
dated 17/09/2011, it is prequalified for Relay &
Plant -Dammam , Saudi Arabia Control Panels, 230kV and above as confirming
to SEC specification # 31-TMSS-01, Rev.0 with
First Industrial City of Dammam, P.O. the following conditions:
Box 2389, Dammam 31451, Saudi
Arabia All type, special, routine and sample tests as per
SEC specifications/standards shall be carried out
Contact Person - +966500594704 on the first batch of Relay & Control Panels to be
Phone - +966138100234 Ext 3267 supplied to SEC, in case of securing an order, in
Email ID - [email protected] , the presence of three (3) SEC Engineers & one
[email protected] (1) approved Independent Inspection Agency
Website - http://www.wescosa.com/ Inspector in an Independent Testing Laboratory .
All the related costs for witnessing the tests will
be borne by the manufacturer. This was
confirmed by WESCOSA-Dammam through letter
# Nil dated 16/06/2010.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 16th june, 2010.

9. 1 Page 247 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL SYSTEMS Rating: Type tests PQ Letter


Saudi Arabia Relay and control panel up to 380kV conducted in King Based on TS&SD letter# 09-01251-03032301
Saud University dated 03rd. May 2009 UP TO 380KV as
Plant -Riyadh Saudi Arabia confirming to SEC specification # 31-TMSS-01.

Po Box 301 , Riyadh 11411 ,North Righ WARRANTY:


Road Between Exit 5 & 6 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Riyadh installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Sultan Alghamdi " VIP first turnkey project in case of contract award or
key Account Manegr "; Saleh date of first delivery in case of direct material
Almehaijeen "Projects Sales Engineer " supply order as confirmed by the manufacturer
Phone - 920006111 through their letter no.AES-380kV-PQA 2009/07,
Contact Person Email ID - dt: 10th March, 2009..
[email protected];
[email protected]
Website - www.alfanar.com

ABB-Ludvika
SWEDEN

Plant -Sweden

Ludvika, Sweden

Contact Person - Mr. Magnus


Johansson
Phone - +46 240 783228
Email ID -
[email protected]
Website - http://www.abb.se/

9. 1 Page 248 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NOUR INDUSTRIES Stud welded/ NISAP/ Rating up to Tests performed at PQ letter:


Saudi Arabia 132kV DEKRA Certifications Based on S&SD letter MPQ # 1211379 dated
Laboratory in August 09, 2018, Nour Industries, Riyadh, KSA is
Plant -Riyadh Netherland during pre-qualified for Relay & Control Panels as
25th and 26th June conforming to National Grid SA specification #
Riyadh – KSA, exit 18. Al Manakh 2018, report no. – 31-TMSS-01 with the following conditions:
industrial area, P.O. Box 21557, Riyadh 127000125-340-IR-0
11485 Kingdom of Saudi Arabia 1 Rev.01 WARRANTY:
Ten (10) years extended warranty/guarantee in
Contact Person - Eng. Tariq Azzam respect of defects due to design, manufacture,
Phone - +966114776555, installation & workmanship from the date of
+966114787171 Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] first turnkey project in case of contract award or
Contact Person Email ID - date of delivery in case of direct material supply
[email protected] order, as confirmed in writing by Nour Industries,
Website - [email protected] Riyadh, KSA through their letter # Nil dated May
21, 2017.

Ingenious Network FZC Power Flow Contracting NGSA-RCP-16001-B / Up to 132KV Ingenious Network PQ Letter
United Arab Emirates Siteen Street, Al-Malaz, FZC- Sharjah, UAE Based on S&SD letter # 17-00160-1-30504401
Dsitrict P.O Box 325917, successfully dated January 19, 2017, Ingenious Network FZC-
Plant -Saif Free Zone, Sharjah, UAE Riyadh-11371, KSA completed type Sharjah, UAE is pre-qualified for Relay & Control
+966 11 4734876 Panels up to 132kV as conforming to National
Q3-047 Sharjah Airport International Rami.azzam@powerflo Grid SA specification # 31-TMSS-01, with the
Free Zone (SAIF Zone) Al Dhaid Road, w-sa.com following conditions:
P.O Box 120110, Sharjah, United Arab
Emirates WARRANTY:
Ten (10) years extended warranty from the date
Sharjah of PAC of the first project (in case of contract
award) or date of first delivery (in case of direct
Contact Person - Mr. Tabish M. Ismail, material supply order), as confirmed, through
Sales & Marketing their Letter No. PQN-SEC-15001-RCP-6A dated
Phone - +971 6 5579471 June 6,2015 shall be applicable for all Relay &
Email ID - Control Panels to be supplied to SEC/National Grid
[email protected] SA.
Contact Person Email ID -
[email protected]
Website -
www.ingenious-network.com

9. 1 Page 249 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. Type/Model - Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.

Plant -2Nd Industrial Area,Riyadh,, Previous name was ABB Electrical Industries
Company Ltd, and change to ABB Contracting Co.
Po Box 325841 Riyadh,11371 KSA Ltd based on S&SD letter #20-01681-30504401
dated October 01, 2020
Riyadh

Contact Person - Mr. Ahmed Abubasha


Contact Person Email ID -
[email protected]

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Innovative Systems Co. Ltd. PQ Letter


Saudi Arabia Based on S&SD letter # MPQ8812379 dated
January 03, 2022, the manufacturer is
Plant -Riyadh KSA prequalified for Integration and Testing Facility for
RELAY & CONTROL PANEL as conforming to
Innovative Systems - Street No. 20 National Grid SA specification #31-TMSS-01, with
Along Street 59 Al Kharj Industrial City the following conditions:
Riyadh Saudi Arabia
WARRANTY
Riyadh Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
Contact Person - Kamal Al Muhanna, contract award) or date of first delivery (in case
CEO Rameez Mulki Substation of direct material supply order), as confirmed
Automation BU Manager through their Letter #Nil dated May 21, 2020, shall
Phone - +966114608160/61 be applicable for the equipment to be supplied to
Email ID - [email protected] SEC/National Grid SA.
[email protected]

Total = 29

9. 1 Page 250 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SUBSTATION PANELS
9. 2
AUXILIARY AC/DC PANELS Applicable Standards: 31-TMSS-02

AG PCS SWITCHGEAR WARRANTY


MANUFACTURING L.L.C Ten (10) years extended warranty/guarantee in
United Arab Emirates respect of defects due to design, manufacture,
installation & workmanship from the date of
Plant -Ajman /U.A.E Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
U.A.E P.O.Box - 5239 Dubai , United date of first delivery in case of direct material
Arab Emirates supply order
Enclosures are manufactured in STAR
Contact Person - Mr. Zia ul haq ELEVATOR SYSTEM & METAL TECHNOLOGY
GENERAL MANAGER LLC (former ETA-PCS) Dubai .
Phone - +971 55 300 35 36
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - http://www.etapcs.com/

KONCAR ELEKTRICNI UREDAJI D.D Nesma Telecom & AC Distribution Board , 400/230 V, AC Distribution PQ Letter
CROATIA Technology Co. Ltd. 4500 A, 85kA for 1Sec. and rated Board type test Based on S&SD letter#18-04543-30504401.
(NESMA ELECTRIC) Insulation voltage 1000 V. performed on dated January 02, 2019, the manufacturer is
Plant -Zagreb/Croatia - Hrvatska Asfan Road, Azzam DC Distribution Board , 125 V, 1000A , September 18 to prequalified for AUXILIARY AC/DC PANELS as
Compound Building # 1 25kA for 1Sec. and rated Insulation October 20-2017 in confirming to NG/SEC specification #
Končar-Električni Uređaji D.D. Prisoje P.O. Box 7195, City : voltage 800 V. CESI-IPH Berlin 31-TMSS-02, with the following condition:
29A, 21232, Dicmo, Hr Jeddah,Saudi Arabia Germany testing
+966 5360 24245 , Engr. laboratory Report # WARRANTY
Contact Person - Mr. Ljubomir Zubčić, Ahmed Elafifi 06992-17-0658-2 Ten (10) years extended warranty in respect of
Phone - +385 21 778 512; +385 91 374 [email protected] DC Distribution the defects due to design, manufacturing,
2009 ; +385 021 778 516 m Board type test installation and workmanship from the date of the
Email ID - Email performed on Provisional Acceptance Certificate (PAC) of the
:[email protected] September 18 to first project (in case of contract award) and from
Website - Web: October 20-2017 in the date of first delivery in case of direct material
http://www.koncareu.hr CESI-IPH Berlin supply order shall be provided as confirmed by
Germany testing the manufacturer through their letter #Nil dated
laboratory Report # January 12, 2018.
06993-17-0659-1

9. 2 Page 251 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EAST & WEST FACTORY


Saudi Arabia

Dammam , Saudi Arabia

Website -
http://www.atco.com.sa/en/manufactu
ring east west factory.asp

ELECTRICAL PANEL BOARD


FACTORY/HAWA TRADING
Saudi Arabia

Dammam , Saudi Arabia

Website - http://www.hawaepbf.com

EPS LTD. (GROUPE SCHNEIDER)


Saudi Arabia

Po Box 89249, 2Nd Industrial City


Riyadh - 11682, Saudi Arabia

Contact Person - Mr.Mr. Ahmed


Majrashi Mr. Bhaskar Sahu
Phone - +966-551304199
Email ID -
[email protected]
m
Website -
http://www.schneider-electric.com.sa

9. 2 Page 252 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ELECTRICAL INDUSTRIES CO. LTD ABB Electrical Ind. Co


(ABB/AEIL) Ltd. (ABB EIL)
Saudi Arabia CONTACT PERSON:
Ahmad Ibrahim, Head
Plant -2Nd Industrial Area, Corner No. Office, Riyadh; KSA
61, 224 Street Riyadh Phone: +966 11 484
5600 Mobile: 055 4040
Saudi Arabia 593
[email protected].
Contact Person - Mr. Naiem Sharqaui com
Phone - +966-0504 206 711
Email ID - [email protected]
Website - http://www.abb.com.sa/

META SWITCHGEAR COMPANY Rating: The tests have been Previously MEMF-ETA Switchgear Manufacturing
Saudi Arabia ACDB 230/400 Vac, upto 3200 A, 75 conducted at CPRI, Company, Riyadh, Saudi Arabia [The name has
kA, 1 sec. India, witnessed by been changed based on S&SD letter #
P. O. Box 61891, Riyadh 11575, Saudi UL & SGS Engineers 14-02218-01-30504401 dated March 23, 2014].
Arabia,Near 2Nd New Industrial, 2Nd DCDB 800 A, 25 kA, 1sec. and certificates and
Phase Riyadh 11575, Saudi Arabia test reports are PQ Letter:
(Branch Of Memf Electrical Industries issued by UL. SGS S&SD letter # 14-02218-01-30504401 dated
Co.) inspection report March 23, 2014 & TS&SD letter
CHN/VCS/014/2014 #11-F03210/01-03032301 dated 29/11/2011
dated 24/01/2014 pre-qualified for AC&DC Panels.
for ACDB & DCDB
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by MEMF-ETA
Switchgear Manufacturing Company through
letter # META/11/13/AM, dated 21st Feb, 2011.

MUSAID SWITCHGEAR,
Saudi Arabia

9. 2 Page 253 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Rawabi Electric Co.


Saudi Arabia

Dammam Saudi Arabia , Second


Industrial City

Contact Person - Mohammed Alsaihati,


Sales & Marketing Manager; Fawzi
Al-Alwan, General Manager
Contact Person Email ID -
[email protected]
om; [email protected]
Website - http://www.remal.com/

SIEMENS
Saudi Arabia

Plant -Jeddah

Website - http://www.siemens.com.sa

9. 2 Page 254 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

WAHA ELECTRIC SUPPLY CO. OF PQ Letter:


SAUDI ARABIA-(WESCOSA) Rating: Based on TS&SD Letter #
Saudi Arabia up to 132kV 11-01751/01-03032301, dated 27/06/2011, it is
pre-qualified for Auxiliary AC & DC Panels up to
Plant -Dammam Saudi Arabia 132kV only.

CONDITION:
All type, special, routine and sample tests as per
SEC specifications/standards shall be carried out
on the first batch of each type of Auxiliary
AC&DC Panels to be supplied to SEC in case of
securing an order in the presence of three (3)
SEC engineers & one (1) approved independent
inspection agency Inspector in an independent
testing laboratory. All the related costs for
witnessing the tests will be borne by the
manufacturer. This was confirmed by
WESCOSA-Dammam through letter # Nil dated
18/05/2010.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by
WESCOSA-Dammam through letter # Nil dated
30/08/2010.

Advanced Technical Solutions Previously " MOHAMMAD AL –OJAIMI FACTORY


Company for Industry (MATCO) ", the name has been changed to Advanced
Saudi Arabia Technical Solutions Company for Industry
(MATCO)
Plant -Riyadh , Saudi Arabia

Website - http://www.alojaimi.com/Our
Companies/Introduction - Mohammed
Al-Oja/introduction - mohammed
al-oja.html

9. 2 Page 255 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL Type / Model: AC & DC


Saudi Arabia
Rating: up to 5000A
Plant -Saudi Arabia

Po Box 301 , Riyadh 11411 ,North Righ


Road Between Exit 5 & 6

Riyadh

Contact Person - Sultan Alghamdi " VIP


key Account Manegr "; Saleh
Almehaijeen "Projects Sales Engineer "
Phone - 920006111
Contact Person Email ID -
[email protected];
[email protected]
Website - www.alfanar.com

NOUR INDUSTRIES Type test completed Based on S&SD letter# 16-04708-1-30504401


Saudi Arabia dated June 6, 2016, it is prequalified for Auxiliary
AC/DC Panels as conforming to National Grid SA
Plant -Riyadh Material Specification
#31-TMSS-02 with the following conditions:
Riyadh – KSA, exit 18. Al Manakh
industrial area, P.O. Box 21557, Riyadh • Ten (10) years extended warranty from the
11485 Kingdom of Saudi Arabia date of PAC of the turnkey project in case of
contract award and date of delivery in case of
Contact Person - Eng. Tariq Azzam direct material supply order, as confirmed
Phone - +966114776555, by the manufacturer through letter
+966114787171 #NI/PQ/2016/05/15/001
Email ID - [email protected] dated May 15, 2016
Contact Person Email ID -
[email protected]
Website - [email protected]

Total = 14

SUBSTATION PANELS
9. 3
TERMINAL BLOCKS Applicable Standards: 31-TMSS-06

9. 3 Page 256 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CONNECTWELL INDUSTRIES PVT. LTD. Completed for PQ Lettter


INDIA approved types Based on S&SD letter# 13-07512-030504401
dated December 09, 2013, it is pre-qualified for
Plant -Dombivli , India terminal blocks as conforming to National Grid SA
specification # 31-TMSS-06, Rev.0 with the
D-7, Phase-2, M.I.D.C, Dombivli-421 204 following condition:

Contact Person - Mr.Sandeep Saheta WARRANTY


Phone - +91 251 3980 800 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: Nov 27, 2012.

ELMEX ELECTRIC PVT. LTD. Type test completed PQ Lettter


INDIA Based on S&SD letter # 15-00579-04-30504401
dated December January 7th, 2016, it is
134-135 GIDC Estate Por – pre-qualified for Terminal
Ramangamdi Vadodara 391 243 Blocks as conforming to National Grid SA
Gujarat – India specification # 31-TMSS-06, with the following
conditions:
Contact Person - Mr.Daxay Soni,
Territory Manager WARRANTY
Contact Person Email ID - Ten (10) years Extended Guarantee / Warranty
[email protected] from the date of PAC of first Project (in case of
contract award) or from the date of delivery for
the direct material supply order. This was
confirmed, through their Letter #
EEPL/2015-16/PQ/001 dated 21/12/2015.

PHOENIX
GERMANY

Website -
http://www.phoenixcontact.com/termin
al-blocks/26840.htm

9. 3 Page 257 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

WEIDMULLER
GERMANY

Website - http://www.weidmuller.com/

WIELAND ELECTRIC GMBH PQ Lettter


GERMANY Based on S&SD letter# 13-05908-30504401
dated December 04, 2013, it is pre-qualified for
Plant -Bamberg , Germany, terminal blocks as conforming to National Grid SA
specification # 31-TMSS-06, Rev.0 with the
He&S Gmbh, Karl-Weinmair-Str 8, following condition:
D-80807, Munchen, Germany
WARRANTY
Contact Person - Mr. Dipl. Ing Haysam Ten (10) years extended warranty/guarantee in
El-Tibi respect of defects due to design, manufacture,
Email ID - installation & workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #bamberg dt: july 20, 2012.

Cabur PQ Letter:
ITALY • Based on S&SD letter # 17-0071-030504401
dated January 09,2017, Cabur, Altare- Italy is
Plant -Altare- Italy pre-qualified for Terminal Blocks as conforming to
National Grid SA specification # 31-TMSS-06,
Contact Person - JAL International, Mr. with the following conditions:
Muhammad Sajjad Manzoor
Contact Person Email ID - WARRANTY:
[email protected] • Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter No. NIL
dated 18/12/2015.

9. 3 Page 258 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KLEMSAN ELEKTRIK ELEKTRONIK Terminal Based on S&SD letter # 16-01206-1-30504401


SANAYI VE TICARET AS Block (type WGO 4, WGO PB6 & WGO dated 21st February 2016, the manufacturer is
TURKEY Y6) prequalified for Terminal Block with the following
condition:
Plant -. • Ten (10) years Extended Guarantee / Warranty
from the date of PAC of first Project (in case of
Kemalpasa Yolu contract award) or from the date of delivery for
3. Km the direct material supply order. This was
Kemalpasa 35170 confirmed, through their Letter # Nil dated
Izmir – Turkey January 06, 2014.

Contact Person - Mr. Uygar Ertek


,Regional Manager
Phone - Tel: +90232 8770800 , Fax:
+90232 8770806
Contact Person Email ID -
[email protected]
,[email protected]

TE CONNECTIVITY - ENTRELEC
FRANCE - Previously ABB ENTRELEC

Plant -Lyon - France - Previously ENTRELEC

3 rue jean Perrin, 69680 CHASSIEU

Lyon

9. 3 Page 259 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Phoenix Contact GmbH & Co.KG Terminal Block (USST series, OTTA PQ Letter
INDIA series and RSC 5)
Based on S&SD letter S&SD letter
Plant -Haryana, India #MPQ8885399-Class IV(b)- 2020 _Class I(b).
dated September 12, 2022 is pre-qualified for
PHOENIX CONTACT Pvt. Ltd. Terminal Blocks as conforming to National Grid SA
Prithla – Dhatir Road specification # 31-TMSS-06, with the following
Village Dudhola, Palwal. P.O Baghola conditions:
Tehsil 2 District Palwal
Pin-121102 WARRANTY
Haryana-India
Ten (10) years extended warranty from the date
Haryana of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
Contact Person - Mr. Ahmad Alewaidat, of direct material supply order), as confirmed,
Area Sales Manager through their Letter #PxC/ME/AE/21/00200, dated
Phone - +971 4 437 0324 May 4, 2021, shall be applicable for the
Email ID - equipment to be supplied to SEC/National Grid SA.
[email protected],
[email protected],
[email protected]
Website -
http://www.phoenixcontact.com

9. 3 Page 260 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Phoenix Contact GmbH & Co.KG Terminal Block (USST series & OTTA PQ Letter
Poland series) Based on S&SD letter # MPQ8886399-Class IV(b)
-2020_Class I(b) dated December 23, 2021, the
Plant -Tomysl Poland manufacturer is prequalified for TERMINAL
BLOCKS as conforming to National Grid SA
PHOENIX CONTACT Wiel - Nowy specification #31-TMSS-06, with the following
Tomysl Poland conditions:

Tomysl WARRANTY
Ten (10) years extended warranty from the date
Contact Person - Ahmad Alewaidat, of PAC of the first turnkey project (in case of
Area Sales Manager contract award) or date of first delivery (in case
Phone - +971 4 437 0324 of direct material supply order), as confirmed,
Email ID - through their Letter #ST(11-18) dated November
[email protected], 07, 2018 shall be applicable for the equipment to
[email protected], be supplied to SEC/National Grid SA.
[email protected]
Contact Person Email ID -
[email protected],
[email protected],
[email protected]
Website -
https://www.phoenixcontact.com

Total = 10

SWITCHGEAR
10. 1
METAL – ENCLOSED AIR INSULATED SWITCHGEAR 11 KV THROUGH 34.5 KV Applicable Standards: 32-TMSS-01

10. 1 Page 261 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EFACEC ENERGIA MAQUINAS E Bandariyah International 33kV Switchgear: 33kV SWGR: On HOLD based on VP, Engineering letter #
EQUIPAMENTOS ELECTRICOS, S.A Co. Ltd, SWGR type: QBN7 & CB type DIVAC KEMA- Dielectric 23-01260-1-30504401 dated July 26, 2023.
PORTUGAL CONTACT PERSON:Raid Incomer, Bus Section and Bus Riser tests, temperature
Shabsough or Rejith Rating; 2500A @ 40°C, 60Hz, rise test, Short time PQ letter:
Plant -Porto/Portugal Rami , 3rd Floor Building 25kAp(3s) / 65kAp, natural cooled - and Peak withstand Based on S&SD letter # 17-07121/02-030504101
3 Mutlaq complex, P.O. Dimension (W-1300xD-2768xH-2858 current test, CB dated October 24, 2017 EFACEC Portugal is
Parque Empresarial Da Arroteia 4296, Al Khobar-31952, mm). making & breaking pre-qualified for 13.8kV Switchgear Type
(Poente), Apartado 1018 4468-952 S. KSA Outgoing feeder (630 & 1250A) & test, Capacitor bank NORMACEL & CB type DIVAC as conforming to
Mameda De Infesta- Portugal Phone: 966-555010864 Capacitor feeder (1250A) @ 40°C, 60 switching current, latest National Grid SA specification #
& Phone: Hz, 25kA(3s) / 65kAp- natural cooled. ES SC making 32-TMSS-01.
Contact Person - Mr. Abílio Rodrigues: : 966-553712308 Dimension (W-1000xD-2768xH-2858 performance
+351 968331386;+351 229562300, Mr. rshabsough@bandariya mm) CESI: Temperature PQ letter:
Filipe Vila Real: +351 939236215; +351 h.com Or rise test, Arcing due Based on S&SD letter # 17-07122/02-030504101
229562300 [email protected] Circuit Breaker: to internal fault, dated October 10, 2017, EFACEC Portugal is
Email ID - Metal Clad Switchgears: : Incomer & Bus section: 2500A @ 40°C, EFACEC: Mechanical pre-qualified for 33KV Switchgear Type QBN7 &
[email protected]; 60Hz, 25kAp(3s) / 65kAp, EFACEC, endurance test of CB type DIVAC as conforming to latest National
[email protected] & Power Portugal –Type CB DIVAC 3625G, CB & ES. Grid SA specification # 32-TMSS-01
Transformers: Interrupter-(VG6), Opr. Mech: Spring
:[email protected]; charged - CDV2M 13.8kV SWGR:
[email protected] Outgoing feeder: 630A @ 40°C, 60Hz, KEMA- Dielectric
Website - 25kAp(3s) / 65kAp; EFACEC, Portugal – tests, temperature
http://www.efacec.pt/en/switchgear/ Type CB DIVAC 3625B, Interrupter- rise test, Short time
& (VG6), Opr. Mech: Spring charged - and Peak withstand
http://www.efacec.pt/en/transformers/ CDV2M current test, CB
Outgoing feeder: 1250A @ 40°C, 60Hz, making & breaking
25kAp(3s) / 65kAp; EFACEC, Portugal – test, Capacitor bank
Type CB DIVAC 3625D, Interrupter- switching current,
(VG6), Opr. Mech: Spring charged - ES SC making
CDV2M performance
Capacitor feeder: 1250A@ 40°C, 60Hz, CESI: Temperature
25kAp(3s) / 65kAp; EFACEC, Portugal – rise test, Arcing due
Type CB DIVAC 3625D-K, Interrupter- to internal fault,
(VG6-K), Opr. Mech: Spring charged - EFACEC: Mechanical
CDV2M, Capacitor switching current: endurance test of
500A CB & ES.
Earthing switch: EFACEC, Portugal –
Type Qbn7, 25kA (3s)/65kAp.
CT: ALCE Turkey or ABB Czech
Republic lower side of CB of O/G & I/C,
Upper side CB for B/S & B/R .
VT: ALCE Turkey or ABB Czech
Republic

10. 1 Page 262 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

13.8kV Switchgear:
SWGR type: Normacel & CB type
DIVAC
Incomer, Bus Section and Bus Riser
Rating; 3150A @ 40°C, 60Hz,
25kAp(3s) / 65kAp, natural cooled &
3600A/ 4000A @ 40°C, 60Hz,
25kAp(3s) / 65kAp with forced
cooling- Dimensions; Incomer
(W-1000xD-1566xH-2619 mm), Bus
tie (W-1000xD-1666xH-2619 mm) &
Bus riser
(W-1000xD-1566/1666xH-2619 mm).
Outgoing feeder (630 & 1250A) &
Capacitor feeder (1250A) @ 40°C, 60
Hz, 25kA(3s) / 65kAp- natural cooled.
Dimension (W- 750xD-1566xH-2619
mm)

Circuit Breaker:
Incomer & Bus section: 3150@ 40°C,
60Hz, 25kAp(3s) / 65kAp, EFACEC,
Portugal –Type CB DIVAC 1725H,
Interrupter-(VG7), Opr. Mech: Spring
charged - CDV2M
Outgoing feeder: 630A @ 40°C, 60Hz,
25kAp(3s) / 65kAp; EFACEC, Portugal –
Type CB DIVAC 1725B , Interrupter-
(VG4-S), Opr. Mech: Spring charged –
CDV1M
Outgoing feeder: 1250A @ 40°C, 60Hz,
25kAp(3s) / 65kAp; EFACEC, Portugal –
Type CB DIVAC 1725D, Interrupter-
(VG4-S), Opr. Mech: Spring charged –
CDV1M
Capacitor feeder: 1250A@ 40°C, 60Hz,
25kAp(3s) / 65kAp; EFACEC, Portugal –
Type CB DIVAC 1725D-K, Interrupter-
(VG6), Opr. Mech: Spring charged -
CDV2M, Capacitor switching current:
630 A

10. 1 Page 263 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Earthing switch: EFACEC, Portugal –


Normacel, 25kA (3s)/65kAp.
CT: ALCE Turkey or ABB Czech
Republic lower side of CB of O/G & I/C,
Upper side CB for B/S & B/R.
VT: ALCE Turkey or ABB Czech
Republic

10. 1 Page 264 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS Siemens Ltd. 13.8 kV AIS: Type/Model: NXAIR, Type Tests PQ letter:
TURKEY P.O. Box 4621, Jeddah 3600A conducted at IPH Based on S&SD letter # 17-04571-02-30504401
21412, K.SA. CESI-Berlin and dated June 22, 2017, SIEMENS -Turkey is
Plant -Turkey 02 661 8972 For Incomer: KEMA & PEHLA pre-qualified for 13.8KV Switchgear Type NXAIR
Aslam.jameel@siemens. 13.8kV, 3008A, @40 °C, 60Hz, as conforming to latest National Grid SA
Gebze Organize Sanayi Bolgesi, 1000. com 25kA(3s)/65kAp, AFLR with Natural specification # 32-TMSS-01, with the following
Cd. No. 1004, 41480-Gebze, Kocaeli, cooling, Dimensions (2500H X 1000W X conditions:
Turkey 2250D), CT Upper & Lower of CB
13.8kV, 3600A @40 °C, 60Hz, 25kA Warranty :
Gebze, Kocaeli (3s)/65kAp, AFLR with Forced cooling • Ten (10) years extended warranty/guarantee in
(4-fans), Dimensions (2500H X 1000W respect of defects due to design, manufacture,
Contact Person - Mr. Ediz Gizlier X 2250D), CT Upper & Lower of CB installation & workmanship from the date of
Phone - +90 (262) 676 2000 Circuit Breaker: 3AE1666-7, 13.8kV, Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] 3150A, @40 °C, 60Hz , 25kA first turnkey project in case of contract award or
Contact Person Email ID - (3s)/65kAp, Vacuum Interrupter: date of delivery in case of direct material supply
[email protected] VS17040, Opr. Mechanism: SION order, as confirmed in writing by the
Website - www.siemens.com.tr 3AE1666 manufacturer through their letter #
Earthing Switch: Siemens, Turkey, AEL-E/PQ/NXAIR/02/2013 dated July 25, 2014.
Type: 174-3138.3
CT & VT: ALCE, Turkey/Pfiffner, Turkey
For Bus Section:13.8kV, 3008A, @40 °
C, 60Hz, 25kA(3s)/65kAp, AFLR with
Natural cooling, Dimensions (2500H X
1000W X 2250D), CT Upper & Lower
of CB
13.8kV, 3600A @40 °C, 60Hz, 25kA
(3s)/65kAp, AFLR with Forced cooling
(4-fans), Dimensions (2500H X 1000W
X 2250D), CT Upper & Lower of CB
Circuit Breaker: 3AE1666-7, 13.8kV,
3150A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VS17040, Opr. Mechanism: SION
3AE1666
CT & VT: ALCE, Turkey/Pfiffner, Turkey
For Bus Riser:
13.8kV, 3008A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2300H X 1000W X
1750D)
13.8kV, 3600A @40 °C, 60Hz, 25kA
(3s)/65kAp, AFLR with Natural

10. 1 Page 265 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Ventilation, Dimensions (2300H X


1000W X 1750D)
VT: ALCE, Turkey/Pfiffner, Turkey
For Outgoing Capacitor Bank Feeder:
13.8kV, 1250A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2350H X 800W X
1750D), CT Upper & Lower of CB;
Circuit Breaker: 3AE5664-3, 13.8kV,
1250A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VSS12-1-31-K4, Opr. Mechanism:
SION 3AE5664, Capacitor Bank back to
back switching current: 684A
Earthing Switch: Siemens, Turkey,
Type: 174-3138.3;
CT & VT: ALCE, Turkey/Pfiffner,
Turkey.
For Outgoing Feeder:
13.8kV, 800A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2300/2350H X
800W X 1750D), CT Upper & Lower of
CB;
Circuit Breaker: 3AE5664-1, 13.8kV,
1250A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VSS12-1-31-K4, Opr. Mechanism:
SION 3AE5664;
Earthing Switch: Siemens, Turkey,
Type: 174-3138.3
For Outgoing Feeder (With Bus Bar
Earthing Switch):
13.8kV, 800A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2350H X 800W X
1750D), CT Upper & Lower of CB;
Circuit Breaker: 3AE5664-1, 13.8kV,
1250A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VSS12-1-31-K4, Opr. Mechanism:
SION 3AE5664;

10. 1 Page 266 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Earthing Switch: Siemens, Turkey,


Type: 174-3138.3;
CT & VT: ALCE, Turkey/Pfiffner,
Turkey.
For Metering Panel:
13.8kV, up to 3600A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
Ventilation, Dimensions (2300H X 800W
X 1750D);
VT: ALCE, Turkey/Pfiffner, Turkey

13.8 kV AIS: Type/Model: NXAIR,


2500A
For Incomer:
13.8kV, 2500A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2300H X 1000W X
1750D), CT Upper & Lower of CB;
Circuit Breaker: 3AE1666-6, 13.8kV,
2500A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VS17040, Opr. Mechanism: SION
3AE1666;
Earthing Switch: Siemens, Turkey,
Type: 174-3138.3;
CT & VT: ALCE, Turkey/Pfiffner,
Turkey.
For Bus Section:
13.8kV, 2500A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2300H X 1000W X
1750D), CT Upper & Lower of CB;
Circuit Breaker: 3AE1666-6, 13.8kV,
2500A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VS17040, Opr. Mechanism: SION
3AE1666;
CT: ALCE, Turkey/Pfiffner, Turkey.
For Bus Riser:
13.8kV, 2500A, @40 °C, 60Hz,

10. 1 Page 267 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

25kA(3s)/65kAp, AFLR with Natural


cooling, Dimensions (2300H X 800W X
1750D);
VT: ALCE, Turkey/Pfiffner, Turkey.
For Outgoing Capacitor Bank Feeder:
13.8kV, 1250A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2300H X 800W X
1750D), CT Upper & Lower of CB;
Circuit Breaker: 3AE5664-3, 13.8kV,
1250A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VSS12-1-31-K4, Opr. Mechanism:
SION 3AE5664, Capacitor Bank back to
back switching current: 684A;
Earthing Switch: Siemens, Turkey,
Type: 174-3138.3;
CT & VT: ALCE, Turkey/Pfiffner,
Turkey.
For Outgoing Feeder:
13.8kV, 800A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2300/2350H X
800W X 1750D), CT Upper & Lower of
CB;
Circuit Breaker: 3AE5664-1, 13.8kV,
1250A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VSS12-1-31-K4, Opr. Mechanism:
SION 3AE5664;
Earthing Switch: Siemens, Turkey,
Type: 174-3138.3;
CT & VT: ALCE, Turkey/Pfiffner,
Turkey.
For Outgoing Feeder (With Bus Bar
Earthing Switch):
13.8kV, 800A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2350H X 800W X
1750D), CT Upper & Lower of CB;
Circuit Breaker: 3AE5664-1, 13.8kV,
1250A, @40 °C, 60Hz , 25kA

10. 1 Page 268 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

(3s)/65kAp, Vacuum Interrupter:


VSS12-1-31-K4, Opr. Mechanism:
SION 3AE5664;
Earthing Switch: Siemens, Turkey,
Type: 174-3138.3;
CT & VT: ALCE, Turkey/Pfiffner,
Turkey.
For Metering Panel:
13.8kV, up to 3600A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
Ventilation, Dimensions (2350H X 800W
X 1750D);
VT: ALCE, Turkey/Pfiffner, Turkey.

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

10. 1 Page 269 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL SYSTEMS 13.8kV SWGR: Type tests were PQ Letter:


Saudi Arabia conducted in PT&T TS&SD letter # 09-02613-01-03032301 dated
1. Type / Model: NES-H Power Testing 13th September 2009 for 13.8kV AIS Natural
Plant -3Rd Industrial Area, Al Kharaj Technology Institute cooled.
Road, Riyadh Saudi Arabia RATING: – Korea from 6-31
13.8kV, 3150A @ 40°C, 60Hz, july, 2009 S&SD Letter 11-01668-03032301 dated June 01,
Po Box 301 , Riyadh 11411 , North Righ 25kA(3s)/65kAp, IP4X, with NATURAL 2011 for 13.8kV AIS Forced cooled
Road Between Exit 5 & 6 Riyadh , COOLING. PT & TI, Korea #
Saudi Arabia R49-1244, dated WARRANTY
Incomer (CT upper & lower side of CB): July 06-22, 2009, PT Ten (10) years extended warranty/guarantee in
Riyadh (1000x2793x1880mm), Bus riser & TI, Korea # respect of defects due to design, manufacture,
(1000x2793x1880mm): 3150 @ 40°C, R49-1245, dated installation & workmanship from the date of
Contact Person - Sultan Alghamdi " VIP 60Hz, 25kA (3s)/65kAp, Bus Section July 06-29, 2009, PT Provisional Acceptance Certificate (PAC) of the
key Account Manegr "; Saleh (1000x2600x1880mm) & TI, Korea # first turnkey project in case of contract award or
Almehaijeen "Projects Sales Engineer " R49-1246, dated date of first delivery in case of direct material
Phone - 920006111 Outgoing feeder (CT upper & lower July 08-15, 2009, PT supply order, as confirmed by the manufacturer
Contact Person Email ID - side of CB) (800x2793x1880mm): & TI, Korea # through their letter no. MVS PQR 801-06, dt:
[email protected]; 1250A @ 40°C, 60Hz, 25kA(3s)/65kAp. R49-1247, dated 28.01.2009.
[email protected] July 08-15, 2009, PT
Website - www.alfanar.com CIRCUIT BREAKERS: & TI Korea # PQ Letter
3150A Incomer & Bus Section: R49-1248, dated
LVB-17M-40D/30-1E2H (vacuum July 22-29, 2009, PT Based on S&SD letter #22-00866-30504401.
interrupter LV10403). &T, Korea # dated July 18, 2022, the manufacturer is
LVB-17M-32D/30-1E2H-DB (interrupter R210-2183, dated prequalified for METAL – ENCLOSED AIR
LV 12503BC) 28 & 29 Nov: 2010, INSULATED SWITCHGEAR 13.8kV Type “Alfa-12”
PT &T, Korea # as confirming to National Grid SA specification #
1250A Outgoing Feeder: R210-2499, dated 32-TMSS-01, with the following conditions:
LVB-17M-25D/12-1E2H (vacuum 30 Nov: 2010, PT&T
Interrupter LV10252). # R214-0235,
March,26 to April WARRANTY
Capacitor Bank: 15, -2014, KERI #
LVB-17M-25D/12-1E2H-DB (Vacuum 2014TC00794, dated Ten (10) years extended warranty from the date
Interrupter LV12503), 630A, Class C2 28 Aug: to 26 Sept: of PAC of the first turnkey project (in case of
2014, CESI # contract award) or date of first delivery (in case
Circuit Breaker from LSIS, Korea B8011791, dated of direct material supply order), as confirmed,
May 18, 2018 & CESI through their Letter # Nil dated July 28, 2020,
Earthing Switch: SEH/ MH31M & SEH/ # C1006812 dated shall be applicable for the equipment to be
MH31SM from LSIS, Korea April 14, 2021. supplied to SEC/National Grid SA.

CT & VT: ALCE, Turkey For Type/Model:


Alfa-12
TYPE/MODEL: NES-H 1. CESI 1021286-

10. 1 Page 270 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

1, dt: 18-11-2021 TR
FORCED COOLED IAC 1250A
Rating: 2. CESI 200218,
13.8kV, 4000A @ 40°C, 60Hz, dt: 15-01-2022 TR
25kA(3s)/65kAp, IP4X, with FORCED IAC 3150A
COOLING, with CT upper & lower side 3. CESI
of CB. C1019437, dt: 12-11
-2021, TTR
Incomer (1000×2793x1880mm), DIELECTRIC LINEUP
VCB-LVB-17M-40D/301E2H, 4. CESI C1020284
Interrupter-10403 dt: 23-11-2021- TTR
DIELECTRIC BUS
Bus section (1000×2793x1880mm), EARTHING
VCB-LVB-17M-40D/301E2H, 5. CESI
Interrupter-10403 C1019677, dt: 12-11
-2021- TTR PARTIAL
• Bus riser (1000×2793x1880mm) DISCHARGE
6. CESI
C1019717, dt: 16-11
2. Type/Model - Alfa-12 -2021- TEMP RISE
3150/1250A
Rating: I/C, B/S, B/R-13.8kV, 3150A 7. CESI
(Natural cooled), 3600A (forced C1020459, dt: 18-11
cooled- fan in Incomer/BS/BR panels) -2021- TEMP RISE
@40°C, 60Hz, 25kV (3s), IP4X, AFLR, 3600A
25kA (1s) 8. CESI
C1020068, dated 19
Outgoing/ Consumer/capacitor feeders -11-2021- Short time
- 1250A @40°C, 60Hz, 25kV (3s), IP4X, peak withstand
AFLR, 25kA (1s) current
9. CESI C1020811
Incomer/Bus section/Bus Riser/Bus TTR STC Main Earth
metering Panels: 2500 (Swgr) / 2823 31.5kA - Short time
mm (Swgr with LV Compartment + peak withstand
Control duct) (H) X 1850mm (D) X current
1000mm (W), CT on both side of CB 10. CESI
for I/C & B/S C1019877, dt: 18-11
Outgoing/ Consumer/capacitor feeders: -2021 TTR 1250A
2500 (Swgr) / 2823 mm (Swgr with LV CB T10, T30, T60,
Compartment + Control duct) (H) X T100s(a,b), T100a,
1850mm (D) X 650mm (W), CT on both OP2
side of CB. 11. KERI #

10. 1 Page 271 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

2016TC00421, dated
Circuit Breaker type: 12-12-2016 1250A
Incomer/BS: VH-17H32D32 CB -SP/DEF
(Interrupter- LV8A)-LSIS/Korea – 12. KERI #
Vacuum type, Opr. Mech: SUSOL, 2016TC00421, dated
Capacitor bank back to back switching 12-12-2016 1250A
current: 830A, Inrush current 20kA, CB-CC2
Inrush frequency 4250Hz, Class-C2, 13. CESI C1019555
M2 TR BACK TO BACK
CAPACITIVE 1250A
Outgoing/Consumer/capacitor feeders: 14. CESI C1019577
VL-17H32A13 (Interrupter-LV6) TTR CB Mechanical
-LSIS/Korea - Vacuum type, Opr. Mech: Endurance 1250A
SUSOL, Capacitor bank back to back 15. CESI C1019878
switching current: 830A, Inrush TTR 3150A T10,
current 20kA, Inrush frequency T30, T60,
4250Hz, Class-C2, M2 T100s(a,b), T100a,
OP2
Earthing switch: AES 31.5 (Alfanar 16. KERI #
Electrical System/KSA), 17.5kV-25kA 2015TS03146, dated
(3s)-M1 03-12-2015 3150A
CB- SP/DEF
17. KERI #
2015TS03146, dated
03-12-2015 3150A
CB- CC2
18. CESI C1019299
TR BACK to BACK
CAPACITIVE 3150A
19. CESI C1019578
TTR CB Mechanical
Endurance 3150A
20. CESI
C1020003, dt: 19-11
-2021 TTR ES
Making
21. CESI #
C2001600, Dt: 25-11
-2021 ES
Mechanical
Endurance
22. CESI

10. 1 Page 272 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

C2001601, dt: 14-11


-2021 TTR Interlock
Testing
23. CESI #
C1021004, dt: 01-12
-2021 – IP coding

10. 1 Page 273 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ELECTRICAL INDUSTRIES CO. LTD 33kV AIS: PQ Letter:


(ABB/AEIL) Type / Model: Classic ZS3 TS&SD letter # 06-037-03032300, dated April 16,
Saudi Arabia 2006 for 13.8kV AIS natural cooled, UniGear ZS1
Rating: 33kV, up to 2500A@ 40°C with
Plant -2Nd Industrial Area, Corner No. natural cooling, IP4X, CT lower side of TS&SD letter # 09-02169/01-03032301, dated
61, 224 Street Riyadh CB August 15, 2009 for CB Capacitor switching.

Saudi Arabia CB type: S&SD Letter 12-03120-01-30504401 dated


VD43620-25(2000A), August 14, 2012 for 13.8kV AIS Forced cooled,
Contact Person - Mr. Naiem Sharqaui VD43612-25(1250A & 800A) UniGear ZS1.
Phone - +966-0504 206 711
Email ID - [email protected] ES type: EK5, 3007N280 S&SD Letter 13-01329-30504401 dated March
Website - http://www.abb.com.sa/ 13, 2013 for VD4 vacuum interrupter factor
13.8kV AIS: location.
NEW VERSION:
CONDITION:
TYPE/MODEL: UniGear ZS1 All VD4 Poles and vacuum Interrupters are from
ABB Calor Emg, Germany (DECMS).
Rating: 13.8kV, 3003A @ 40°C, 60Hz,
25kA(3s)/65kAp with natural cooling, CB Operating Mechanism: EL Operating
IP4X Mechanism form ABB-SACE Italy (ITABB).

Incomer (CT upper & lower side of CB): Circuit breaker up to 24kV, 4000A, 40kA from
(1000x2200/2595x1400/1780mm), ABB-SACE-Italy (ITABB).
Bus Section
(1000x2200/2595x1400mm) &,
Bus riser (800x2200/2595x1400mm):
3003 @ 40°C, 60Hz, 25kA (3s)/65kAp.

Outgoing feeder (CT upper & lower


side of CB):
(800x2200/2595x1400mm): 924A @
40°C, 60Hz, 25kA(3s)/65kAp and
(800x2200/2595x1400mm): 682A @
40°C, 60Hz, 25kA(3s)/65kAp.

Outgoing feeder (CT lower side of CB):


(800x2200/2595x1400mm): 991A @
40°C, 60Hz, 25kA(3s)/65kAp and
(800x2200/2595x1400mm): 648A @
40°C, 60Hz, 25kA(3s)/65kAp.

10. 1 Page 274 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

1600A SWGR:
1600A Incomer
(800x2200/2595x1400mm) ; Bus
Section (800x2200/2595x1400mm, Bus
Riser (650x2200/2595x1400mm: 1607A
@ 40°C, 60Hz, 25kA(3s)/65kAp

CIRCUIT BREAKERS:
Incomer, Bus Section: VD4 17.31-25
(vacuum interrupter VG6), ABB Italy
(embedded pole)

Outgoing Feeders: VD4 17.16-25


(vacuum interrupter VG4/S), VD4
17.12-25 (vacuum interrupter VG4) &
VD4 17.06-25 (vacuum interrupter
VG4), ABB, Italy.

Earthing switch type EK6, ABB-EJF,


Czech.

CT & VT: ABB-EJF, Czech or RITZ


Instrument Transformers GmbH,
Germany

CB FOR CAPACITOR SWITCHING:


VD4 17.12-40 (vacuum interrupter
VG6), 630A, Class C2

HD4 17.12-25 (interrupter SF6), 630A,


Class C2

HD4 17.16-25 (interrupter SF6), 900A,


Class C2

HD4 24.12-25 (interrupter SF6), 630A,


Class C2

FORCED COOLED
Rating:

10. 1 Page 275 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

13.8kV, 3600/4000A @ 40°C, 60Hz,


25kA(3s) / 65kAp, IP4X, with FORCED
COOLING, with CT upper and lower
side of CB.

TYPE/MODEL:
UniGear ZS1 13.8kV SWGR with CT
upper & lower side of CB.

Incomer (1000×2595x1780mm),
VCB-VD4 1731-25,Vacuum
Interrupter-VG6

Bus section (1000×2595x1780mm),


VCB-VD4 1731-25, Vacuum
Interrupter-VG6

Bus riser (800×2595x1400mm)

OLD VERSION:

Type / Model: Classic ZS1

Rating: 13.8kV

ABB-CALOR EMAG CALOR EMAG


GERMANY

Plant -Germany

Website -
http://www.alibaba.com/member/smilja
nmusic/contactinfo.html

AREVA (MACON CEDEX 9)


FRANCE

Website - http://www.areva.com/

10. 1 Page 276 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELEKTROBUDOWA SA 13.8kV SWGR: PQ Lettter


Poland TS&SD letter # 09-01092-03032301 dated 18th.
Type / Model: D-17P April 2009 for 13.8kV AIS Natural cooled.
Plant -Konin , Poland
Rating: WARRANTY
13.8kV, 3000A @ 40°C, 60Hz, Ten (10) years extended warranty/guarantee in
25kA(3s)/65kAp, IP4X, with NATURAL respect of defects due to design, manufacture,
COOLING, CT lower side of CB for installation & workmanship from the date of
Outgoing feeders. Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Incomer (1000x2200x1350mm), Bus date of first delivery in case of direct material
Section (1000x2591x1350mm), Bus supply order.
riser (400x2591x1350mm): 3000@
40°C, 60Hz, 25kA (3s)/65kAp.

Outgoing feeder (750x2591x1350mm):


630A @ 40°C, 60Hz, 25kA(3s)/65kAp.

Outgoing feeder (750x2591x1350mm):


1250A @ 40°C, 60Hz, 25kA(3s)/65kAp.

CIRCUIT BREAKERS:
Incomer, Bus Section: VD4 17.31-25
(vacuum interrupter VG6), ABB Italy
(embedded pole)

Outgoing Feeders: VD4 17.06-25,VD4


17.12-25 (vacuum interrupter VG4),
ABB, Italy

CT & VT: ABB-EJF, Czech

EARTHING SWITCH:
UMR, ELEKTROBUDOWA SA, Poland

10. 1 Page 277 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LSIS METS Middle East Solution Power V17 & CB type LVB17 Type test were PQ Letter:
KOREA, Republic of Technical Services 13.8 kV successfully S&SD letter# 15-03781-2-30504401 dated June
Contact Person:Mr. conducted in KERI 04, 2015,for for MV Switchgear Type “ Solution
Plant -Republic Of Cheongju, Korea Abdul Majeed Atiyyah Incomer, Bus Section and Bus Riser Korea during 16th Power V17” & CB type “ LVB17” rated for 13.8
Vice President & Mr. ratings June to 17th July kV.
Ls Tower, 127 Ls-Ro Dongan-Gu Won Koo Kwon General (W-950xD-2000xH-2620 mm); 3000A 2014 in Presence of
Anyang-Si Syeonnggi-Do 431-848 Manager , P.O. Box: @ 40°C, 60Hz, 25kAp Approved IIA WARRANTY:
Korea 4323 Riyadh - 11491 (3s) / 65kAp, natural cooled. Inspector. Ten (10) years extended warranty/guarantee will
Kingdom of Saudi Arabia. Type Test Report be applicable for all 13.8 kV Medium Voltage
Contact Person - Mr Je Woo Lee Power Tel: +966 1 2424923,Fax: Outgoing feeder & Capacitor feeder #2014TC00634 Switchgear type Solution Power V17 to be
Grid Business Group & +966 1 2424924 (630 A / 1250A) - supplied to SEC/National Grid SA as confirmed
Mr.Kui-Joong,Yun General Manager PQ [email protected] , (W-750xD-2000xH-2620 mm); 1250A through LSIS Letter #013/LSIS-PQ/2015 dated
Dept Powr Grid Business Group [email protected] @ 40°C, 60 Hz, 25kA 26th May 2015.
Phone - +82-2-2034-4541 , (3s) / 65kAp, natural cooled.
82-2-2034-4918 • Circuit Breaker:
Email ID - [email protected] Incomer & Bus section: LSIS, Korea –
,[email protected] Type
(LVB-17M-40D/30-1E2H, Interrupter:
LV10403, Opr. Mech:
Motor-spring, LVB Pro-MEC)
Outgoing feeder: LSIS, Korea-Type
(LVB-17M-25D/12-1E2H,
Interrupter: LV10252, Opr. Mech:
Motor-spring, LVB Pro-MEC)
Capacitor feeder: LSIS, Korea-Type
(LVB-17M-25D/12-1E2H-DB,
Interrupter: LV12503, Opr. Mech:
Motor-spring, LVB Pro-MEC), Capacitor
Bank back to back
switching current-630A.
• Earthing switch Type SEH/MH31SM &
SEH/MH31M.
• CT: ABB, Czech (CT located in upper
& lower side of CB for
I/C, O/G, B/S).
• VT: ABB, Czech

10. 1 Page 278 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR ELECTRICAL EQUIPMENT 33kV SWGR LIMITED TO DTA ONLY; FOR CTA
(KONCAR), SPLIT Type / Model: BVK-s-38 PREQUALIFICATION UNDER PROGRESS
CROATIA
Rating: 33kV,
Plant -Split/Croatia – Hrvatska
CIRCUIT BREAKER:
Koncar Elektricni Uredaji D.D Prisoje
29A, 21232 Dicmo Hr CT & VT:

Contact Person - Mr.Ljubomir Zubcic


Phone - +38521778512, +385 91 374
2009 13.8kV SWGR
Email ID - [email protected]
Website - http://www.koncareu.hr Type/Model: BVK-S-17.5

Rating:

CIRCUIT BREAKER

MITSUBISHI ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Plant -Power Distribution System


Center, Marugame City, Japan

Mitsubishi Electric Corporation Pdsc,


Marketing Department 8 Horai-Cho,
Marugame City, Kagawa, 763-8516,
Japan

Contact Person - Mr. Mitsunori


Yoshizato
Phone - +81-877-24-8012
Email ID -
[email protected]
ric.co.jp
Website -
http://global.mitsubishielectric.com/

POWER CON SWITCHGEAR CONDITION:


United States SWITCHGEAR NOT YET TYPE TESTED

Plant -United States

10. 1 Page 279 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

S&C
United States

Website - http://www.sandc.com/

SIEMENS
United States

Website -
http://www.usa.siemens.com/entry/en/

VA TECH
FRANCE

Plant -France

Website - http://www.vatech-hydro.at

WESCOSA
Saudi Arabia

Plant -Dammam , Saudi Arabia

First Industrial City of Dammam, P.O.


Box 2389, Dammam 31451, Saudi
Arabia

Contact Person - +966500594704


Phone - +966138100234 Ext 3267
Email ID - [email protected] ,
[email protected]
Website - http://www.wescosa.com/

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

10. 1 Page 280 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EPS LTD. (GROUPE SCHNEIDER) 33kV SWGR: PQ Letter:


Saudi Arabia NEW VERSION: TS&SD fax ref. # 09-00073-2-03032301 dated
Type / Model: F400NL 04/02/2009 for 33kV AIS Natural cooled
Po Box 89249, 2Nd Industrial City
Riyadh - 11682, Saudi Arabia Rating: WARRANTY
33kV , 2500A @ 40°C, 60Hz, Ten (10) years extended warranty/guarantee in
Contact Person - Mr.Mr. Ahmed 25kA(3s)/65kAp, IP4X, with NATURAL respect of defects due to design, manufacture,
Majrashi Mr. Bhaskar Sahu COOLING, CT lower side of CB installation & workmanship from the date of
Phone - +966-551304199 Provisional Acceptance Certificate (PAC) of the
Email ID - Incomer (1100x2300x3274mm), Bus first turnkey project in case of contract award or
[email protected] Section (1100x2300x3274mm), Bus date of first delivery in case of direct material
m Riser (1100x2300x3274mm): 2500A @ supply order.
Website - 40°C, 60Hz, 25kA (3s)/65kAp.
http://www.schneider-electric.com.sa PQ Letter:
Outgoing Feeder (900x2300x3274mm): S&SD Letter 12-02860-01-30504401 dated July
1250A @ 40°C, 60Hz, 25kA 24, 2012 for 13.8kV AIS FORCED COOLED
(3s)/65kAp:
PQ Letter:
CIRCUIT BREAKER: Pre-qualified since 24/02/1420H for 13.8kV SWG
SF2(France), Interrupter: 889038 SF2 type MC-Set
(France)

ES type: SMALT TFCM(France)

OLD VERSION:
Type / Model: F400G

Rating: 33kV, up to 2500A @ 40°C,


IP4X, Natural cooled.

CIRCUIT BREAKER
SF1 & SF2

13.8kV SWGR:

Type / Model: Mcset

Rating:
13.8kV, 2500A @ 55°C, 60Hz,

10. 1 Page 281 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

25kA(3s)/65kAp, IP4X, NATURAL


COOLING, CT lower side of CB.

Incomer (900x2400x1800mm), Bus


Section (900x2400x1800mm), Bus
riser (900x2400x1800mm): 2500A@
55°C, 60Hz, 25kA (3s)/65kAp.

Outgoing feeder (700x2400x1800mm):


400A @ 55°C, 60Hz, 25kA(3s)/65kAp.

Outgoing feeder (700x2400x1800mm):


800A @ 55°C, 60Hz, 25kA(3s)/65kAp.

CIRCUIT BREAKERS:
2500 (3150A) Incomer, Bus Section:
LF3 -3150@ 40°C, 60Hz) Interrupter
SF6

2000 (2500A) feeder: LF2-2500,


Interrupter SF6

800A (1250A) Outgoing: LF2-1250,


Interrupter SF6

400A (630A) Outgoing: LF2-630,


Interrupter SF6

Type / Model: Mcset

FORCED COOLED
Rating:
13.8kV, 3600A @ 40°C, 60Hz,
25kA(3s)/65kAp, IP4X, FORCED
COOLED, CT lower side of CB.

Incomer (900×2500X1700), CB-LF3,


Interrupter SF6-LF3-3150A

Bus section (900×2500X1700),


CB-LF3,
Interrupter SF6-LF3-3150A

10. 1 Page 282 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Bus riser (900×2500X1700)

10. 1 Page 283 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AEL –SIEMENS 13.8kV SWGR: 33kV AIS:


Saudi Arabia Type 8BT2 is not acceptable, as the VT is located
TYPE/MODEL: 8BK20 in a separate compartment and connected by
Plant -Jeddah , Saudi Arabia cable.
RATING: 13.8kV, 25kA(3s)/65kAp with
Siemens Factory - Jeddah Modon natural cooling, IP4X PQ Letter
Oasis Industrial Zone - Asfan Road Based on S&SD letter # 24-00483-01-30504401
CB type: 3AH dated February 19, 2024, the manufacturer is
Jeddah prequalified for 13.8kV NXAIR Switchgear as
confirming to National Grid SA specification #
Contact Person - Aslam Jameel Type/Model: 13.8 kV AIS - NXAIR 32-TMSS-01, with the following conditions:
Phone - +966 (12) 661-8972 ; +966 56
790 6195 INCOMER rating: TYPE TEST CONDITION:
Email ID - [email protected] Siemens Jeddah has confirmed to conduct
Contact Person Email ID - 13.8kV, 3600A @40 °C, 60Hz, 25kA complete type test in an accredited test lab in the
[email protected] (3s)/65kAp, AFLR with Forced cooling presence of three (03) SEC/National Grid SA
Website - (4-fans) engineers and one (01) SEC/National Grid SA
http://www.siemens.com.sa/cms/sa/ho approved 3rd party Independent Inspection. All
me/Pages/Default.aspx Outgoing rating: 13.8kV, 800A/125A cost of which shall be borne by the
@40 °C, 60Hz, 25kA manufacturer. This was confirmed in writing by
(3s)/65kAp, AFLR the manufacturer through their letter Ref.
GEN/PQ/SIE-AEL-E/NXAIR/PQ/L2 dated
B/S rating: 18.02.2020
13.8kV, 3600A @40 °C, 60Hz, 25kA
(3s)/65kAp, AFLR with Forced cooling WARRANTY
(4-fans) Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the 13.8kV NXAIR
CIRCUIT BREAKERS Switchgear in respect of the defects due to
design, manufacturing, installation and
Incomer & B/C CB: SION 3AE5666-8, workmanship from the date of Provisional
13.8kV, 3150A, @40 °C, 60Hz , 25kA Acceptance Certificate (PAC) of the first turnkey
(3s)/65kAp, Vacuum Interrupter: project (in case of contract award) or from the
VSA17-1-40, Opr. Mechanism: date of first delivery (in case of direct material
Electrical/SION 3AE5664 / SION supply order), as confirmed by the manufacturer,
3AE1666 3AE1666 through their Letter Ref. #
GEN/PQ/SIE-AEL-E/NXAIR/PQ/L1 dated
Outgoing CB: SION-3AE5664-1 (800A) 17.02.2020
/ 3AE5664-3 (1250A), 25kA
(3s)/65kAp, Vacuum Interrupter VSS
12-1-31K4, Opr. Mechanism:
Electrical/SION 3AE5664 / SION
3AE1666 3AE1666

10. 1 Page 284 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Earthing Switch: Siemens, Turkey,


Type: 174-3138.3

CT & VT: ALCE, Turkey/Pfiffner, Turkey

CT location: Both sides of CB

SWGR dimension: Incomer: 2500 (H) x


2250 (D)x 1000(W)mm, (3600A); B/C:
2500 x 1750 x 1000 mm, (3600A); B/R:
2300 x 1750 x 1000mm; O/G: 2300 x
1750 x 1000mm (up to 1250A); Bus
metering: 2300 x 1750 x 1000mm.

HITACHI LTD 33kV SWGR: Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/Model: letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
Rating:
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, 13.8kV
Tokyo, 101-8608, Japan
Type/Model:
Contact Person - Mr. Masaharu Tsumori
Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

Total = 21

SWITCHGEAR
10. 2
SF6 GAS INSULATED SWITCHGEAR & HYBRID SF6 GAS INSULATED SWITCHGEAR 110kV to Applicable Standards: 32-TMSS-02
132kV

10. 2 Page 285 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens High Voltage Switchgear Co., Siemens Energy Limited 145kV GIS type 8DN8 PQ Letter:
Ltd. Shanghai Saudi Arabia Based on S&SD letter #23-00822/01-30504401
CHINA Business Gate, Building Ratings: 145kV, 3150A@40°C, 60Hz, dated 09-05-2023, the manufacturer is
C-1, 40kA (1s)/104kAp prequalified for 145kV GIS (type 8DN8) as
Plant -Shanghai, P.R. China Airport Road, Qurtubah confirming to National Grid SA specification #
District. CB: 8DN8, 145kV, 3150A@40°C, 60Hz, 32-TMSS-02, with the following conditions:
No. 299 Tian Ning Road, Min Hang P.O. Box 39582, Riyadh 40kA (1s)/104kAp, CB Opr. Mech: FA2
District, Shanghai, P.R. China 11489, (common opr. Mech) TYPE TEST:
Saudi Arabia CB capability: Inductive load switching Fresh Type Tests shall be conducted in an
Shanghai 00966566375966 and Capacitor bank back to back independent testing laboratory in the presence of
kaisar.langoo@siemens- switching: NO (03) SEC/National Grid SA representatives and
Contact Person - 1rst Contact: Mr. Xu energy.com one approved third party inspector during first
Feng Yu- Stan 2nd Contact: Mr. Cai Chi Busbar & Line DS: SEC/ National Grid SA project/ order and all cost
Xiang- Jason 8DN8-TPS-3150A@40°C, 60Hz, 40kA pertaining to tests shall be borne by the
Phone - +86 (21) 24085606 (1s)/104kAp, Opr. Mech: manufacturer. This has been confirmed in writing
Email ID - 8DN8-TPS-47910135 by the manufacturer through letter #
[email protected] SHVS230406KSAPQ01, dated 06 April, 2023.
Contact Person Email ID - 1st Contact: MES: 8DN8-ES- 60Hz, 40kA
[email protected] 2nd (1s)/104kAp, Opr. Mech:
Contact: 8DN8-ES-47910135 WARRANTY:
[email protected] Ten (10) years extended warranty/guarantee to
Website - www.siemens-energy.com HES: 8DN8-HSES- 60Hz, 40kA SEC/National Grid SA for the offered 145kV GIS
(1s)/104kAp, Opr. Mech: type 8DN8 in respect of the defects due to
8DN8-HSES-47915172 design, manufacturing, installation and
workmanship from the date of Provisional
VT: 8DN8 Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # SEC Bulk Tender_
Prequalification, dated February 18, 2022.

10. 2 Page 286 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd 145kV GIS 145kV GIS 145kV GIS
SOUTH KOREA LATEST VERSION LATEST VERSION LATEST VERSION
Type/Model: 145SP-3 Type/Model: Type/Model: 145SP-3
Plant -Ulsan 145SP-3
Rating: 145kV, 2000A/3150A@40 ºC, PQ letter:
1000, Bangeojinsunhwan-doro, 60HZ, 40kA (3s)/104kAp. Type Test performed Based on S&SD letter MPQ #11424110 dated
Dong-gu, Ulsan, South Korea, in KERI, Korea # October 01, 2018, Hyundai Electric & Energy
CB type: 145SP-K3, 145kV, 2018TC00434 Systems Co. Ltd., Korea is pre-qualified for 145
Ulsan 2000A/3150A@40 ºC, 60HZ, 40kA (2018), kV GIS type 145SP-3 as conforming to latest
(3s)/104kAp, Operating mechanism: 2018TC00439 National Grid SA specification # 32-TMSS-02,
Contact Person - Mr. J.W(Jin) Lee 145M-MSCB(Spring charged) . (2018), with the following conditions:
Phone - +966-11-293-2026, CB Capability: Inductive load switching: 2018TC00441
+82-10-4818-0822 YES, Capacitor bank back to back (2018), WARRANTY:
Contact Person Email ID - Switching: YES. 2018TC00442 Ten (10) years extended warranty/guarantee
[email protected] (2018), from the date of (PAC) of the Turnkey project (In
Website - DS type: BDS type: 145SP-BD3 & LDS 2018TC00448 case of contract award) and from the date of
http://www.hyundaielectric.com type: 145SP-LD3 - 2000A/3150A@40 (2018), delivery for the direct material supply order. The
ºC, 60HZ, 40kA (3s) /104kAp, 2018TC00449 guarantee/warranty shall be applicable from first
Operating mechanism: 145M-M3P. (2018), project and shall cover all the cost of materials
2018TC00450 and labor as per warranty/guarantee of materials
MES type: 145SP-ME3, 40kA (3s) (2018), and workmanship and subsequently reduced
/104kAp, Operating mechanism: 2018TC00455 yearly in case of future project award. This was
145M-M3P. (2018), confirmed in writing by Hyundai Electric & Energy
2018TC00456 Systems Co. Ltd., Korea through their letter #
HES type: 145SP-HE3, 40kA(3s) (2018), S370-1703-LSH1 dated # March 29, 2017.
/104kAp, Operating mechanism: 2018TC00458
145M-MSES (spring charged). (2018),
2018TC00459
(2018), NEW VERSION
145kV GIS 2018TC00510 Type/Model: 145SP-1
NEW VERSION (2018),
Type/ Model: 145SP-1 2018TC00511 PQ Letter:
(2018), TS&SD # 04-0692-030320, dated 15-03-2004,
Rating: 145KV, 2500A @40°C, 2017TC00070 pre-qualified GIS type 145SP-1
60Hz,40kA (3s)/ 104kAp (2017),
2016TC00558 PQ Letter
CB type: 145SP-K1, Motor spring (2016), KEMA # Based on S&SD letter # 23-0223-30504101 dated
mechanism 2515-15 (2015). July 26, 2023, the manufacturer is prequalified
for 145kV SF6 Hybrid GIS type 145SP-3 as
CB Capability: confirming to National Grid SA specification #
Inductive load switching: YES 32-TMSS-02, with the following conditions:
Capacitor bank back to back Switching:

10. 2 Page 287 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NO WARRANTY
BDS type: 145SP-3PS1 Ten (10) years extended warranty/guarantee to
LDS type: 145SP-3PS2 SEC/National Grid SA for the offered 145kV SF6
MES type: 145-3PS2 Hybrid GIS type 145SP-3 from the date of
HES type: 145SP-LES2 Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
OLD VERSION: or from the date of first delivery (in case of
Type/ Model: 145SP direct material supply order), as confirmed by the
manufacturer, through their Letter Ref. # Nil dated
Rating: 145kV 21.04.2023

CB type: 145SP-K Hydraulic Previously Hyundai Heavy Industries Co. Ltd [The
mechanism name has been changed based on P&SFD letter
#17-04234/01-030504401 dated May 24, 2017].
CB Capability:
Inductive load switching: NO Previously Hyundai Electric & Energy Systems
Capacitor bank back to back Switching: Co., Ltd., the name has been changed to HD
NO Hyundai Electric Co., Ltd

DS type: 145SP-DS
MES: Type 145SP-ES
HES type: 145SP-LES

145kV HGIS
Type/Model: 145SP-3 (Same model as
pre-qualified 145kV GIS type 145SP-3)
Rating: 145kV – 3150A/2000A@40 ºC,
60HZ, 40kA (3s)/104kAp

10. 2 Page 288 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ILJIN ELECTRIC CO. LTD. META Switchgear GIS Type test completed Based on S&SD letter# 16-2020-01-030504401
SOUTH KOREA Company dated 31.03.2016 it is pre-qualified for 145kV GIS
(Branch of MEMF 145kV GIS type IJS1440-60, type IJS1440-60, 40kA(3s), 3150A as conforming
905-17, Mannyeon-ro, Hwaseong-si, Electrical Industries co) 40kA(3s), 3150A to National Grid SA specification # 32-TMSS-02,
Gyeonggi, KOREA 2nd New Industrial Area with the following conditions:
P.O. Box: 355988, CB type IJC1440-60, Opr. Mech: • Ten (10) years Extended Guarantee / Warranty
Contact Person - Mr. Jeong Kyung Woo Riyadh 11383 IJCM1440-60 (Motor Spring) from the date of PAC of first Project (in case of
, Mr. Jaeho Kim Kingdom of Saudi Arabia contract award) or from the date of delivery for
Phone - +82-2-707-9161 • CB Capability for: the direct material supply order. This was
Contact Person Email ID - Mr.Ahmed Elafifi Induced current switching: YES confirmed by the manufacturer through their
[email protected] , [email protected] +966536024245 Capacitor Bank back to back switching: Letter # ILJHK20160217W dated 17.02.2016
Website - http://www.iljinelectric.co.kr [email protected] YES
.sa
Busbar DS type:IJBDE1440-60
(Opr. Mech: IJBDEM1440-60)

Line DS type: IJBDE1440-60


(Opr. Mech: IJBDEM1440-60)

MES type: IJME1440-60 (Opr.


Mech: IJMEM1440-60)

HES type: IJHE1440-60 (Opr. Mech:


IJHEM1440-60)

Cable compartment type: IJS1440-60

10. 2 Page 289 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. Equipment designations & Ratings: Hitachi Energy Ltd - Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia a) GIS: ELK-04C, 145kV, 3150A @40 Dammam, KSA has and changed to Hitachi Energy Ltd.
ºC, 60HZ, 40kA (3s)/108kAp. successfully
Plant -Dammam b) Circuit Breaker: SD04 completed type tests Previous name was ABB , and changed to ABB
(2GHV010550M0001), 145kV, 3150A on 145kV GIS Type Contracting Co. Ltd based on S&SD letter
PO: 41022, Street 39 cross 144, 2nd @40 ºC, 60HZ, 40kA (3s)/108kAp with ELK-04 at #20-01681-30504401 dated October 01, 2020
Industrial City, Dammam 31521, Saudi spring charge operating mechanism Independent testing
Arabi type: “MSD1 ((2GHV003600)” laboratories KEMA –
CB Capability: Inductive: YES, Netherlands & Based on S&SD letter # 17-06695-01-30504401
Dammam Capacitor Bank: NO PEHLA – dated August 30, 2017, ABB - Al-Dammam, KSA
c) Busbar DS: TX04 Switzerland. is pre-qualified for 145 kV GIS Type ELK-04C as
Contact Person - Abdulmajeed (2GHV010550M0001), 145kV, 3150A conforming to National Grid SA specification #
Alothman ; Mr. Abdullah Hamidaldin ; @40 ºC, 60HZ, 40kA (3s)/108kAp with Type Test reports: 32-TMSS-02 rev.02, with the following
Mr. Jochen Kiefer operating mechanism type “DHS conditions:
Phone - +966 11 2181703; +966 (1HC0070676)”. PEHLA # 22082Ba-3,
500414555 d) Line DS: TX04 Dt: 07-09-2022,
Email ID - (2GHV010550M0001), 145kV, 3150A PEHLA # WARRANTY:
[email protected] @40 ºC, 60HZ, 40kA (3s)/108kAp with 22082Ba-4-0, Dt: Ten (10) years extended warranty from the date
m; operating mechanism type “DHS 07-09-2022, PEHLA of PAC of the project (in case of contract award)
[email protected] (1HC0070676)”. # 20013Ba-1, dated or date of delivery (in case of direct material
m; [email protected] e) Maintenance ES: EM04 07/02 to 24/03-2020, supply order), as confirmed to SEC/National Grid
(2GHV002340), 145kV, 60HZ, 40kA PEHLA # 20014Ba-1, SA, through their Letter No # Nil, dated July 12,
(3s)/108kAp with operating mechanism dated 13/02 to 2017.
type “DHS (1HC0070676)”. 24/03-2020, PEHLA
f) High Speed Earthing Switch: EB04 # 20060Ba-1, dated
(2GHV006000), 145kV, 60HZ, 40kA 02/04 to 17/04-2020, PQ Letter
(3s)/108kAp with operating mechanism PEHLA # 20079Ba-1, Based on S&SD letter # MPQ885018343 dated
type “EB04/2GHV006000)” Spring dated 12/06 to August 20, 2023, the manufacturer is prequalified
charged. 17/06-2020, PEHLA for 145KV GIS type ELK-04 as confirming to
g) CT: CN04 (2GHV010550M0001) # 23048Ba-1, Dt: National Grid SA specification # 32-TMSS-02,
h) VT: PI04 (2GHV010550M0001) 10-03-2023, PEHLA with the following conditions:
i) Cable compartment : HK04F # 22076Ba, Dt:
(2GHV010550M0001), 2500A @40 ºC, 23-09-2022, PEHLA WARRANTY
60HZ, 40kA (3s)/108kAp. # 22097Ba-4, dt: Ten (10) years extended warranty/guarantee to
26-10-2022, PEHLA SEC/National Grid SA for GIS Type ELK-04, 145kV
# 21010Ba, Dt: (Product ID 1HDG008100M0040) rated up to
For 145kV GIS type ELK-04, 145kV 16-04-2021, PEHLA 145kV in respect of the defects due to design,
(1HDG008100M0040) # 19056BA-2, dated manufacturing, installation and workmanship from
24/10-18/12 – 2019, the date of Provisional Acceptance Certificate
Ratings: 145kV, 3150A@40°C, PEHLA # 22132Ba-0, (PAC) of the first turnkey project (in case of
2400A@55°C, 60Hz, 40kA (3s)/108kAp Dt: 27-01-2023 , contract award) or from the date of first delivery
VDE # (in case of direct material supply order), as

10. 2 Page 290 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CB: ELK-04 CB0 (1HDG008100M0040) 281193-TL7-2, dt: confirmed by the manufacturer, through their
(2GHV941502), 145kV, 3150A@40°C, 11-03-2021, KEMA # Letter Ref. # Nil dated 27th December 2020.
60Hz, 40kA (3s)/108kAp, CB Opr. 2526-19, dated:
Mech: HMB 1.6 (common opr. Mech) 29/10 to
Hydro Mechanic Spring 12-12-2019, KEMA # PQ Letter
2092-22, Dt: Based on S&SD letter # 23-02428-30504401,
CB capability: Inductive load switching: 29-03-2022, KEMA # dated November 19, 2023, the manufacturer is
Yes 2331-22, Dt: prequalified for HGIS type ELK-04 as confirming
Capacitor bank back to back switching: 10-11-2022, KEMA to National Grid SA specification # 32-TMSS-02,
Yes # 2529-19, dated with the following conditions:
25-2809/11/2019,
KEMA # 2527-19, WARRANTY
Disconnect and Grounding Switches dated Ten (10) years extended warranty/guarantee to
Designation / Model Number : 22-23/11/2019, SEC/National Grid SA for the offered HGIS in
1HC0071250M0040 PEHLA # 19069Ba-1, respect of the defects due to design,
dated 20-11-2019 to manufacturing, installation and workmanship from
Busbar & Line DS: DE0 26-03-2020, DEKA # the date of Provisional Acceptance Certificate
(1HDG008100M0040)(2GHV961000) 2214475-INC, dated (PAC) of the first turnkey project (in case of
with drive -3150A@40°C, 60Hz, 40kA 23-01-2017, PEHLA contract award) or from the date of first delivery
(3s)/108kAp, Opr. Mech: BAC0 # 22097Ba-1, Dt: (in case of direct material supply order), as
(1HDG571555) 26-10-2022, PEHLA confirmed by the manufacturer, through their
# 22097Ba-2, Dt: Letter Ref. # HV-AO/08-01-2023/002 dated 08th
MES: DE0 (1HDG008100M0040) 26-10-2022, PEHLA January 2023.
(2GHV961000) with drive - 60Hz, 40kA # 20001Ba, dated
(3s)/108kAp, Opr. Mech: BAC0 25-27/05/2020,
(1HDG571555) PEHLA # 20004 Ba,
Dated 09/01 to
HES: ES0 (1HDG008100M0040) 30/06-2020, PEHLA
(2GHV9210002) with drive - 60Hz, # 22097Ba-3-0, Dt:
40kA (3s)/108kAp, Opr. ES0 26-10-2022, KEMA #
(2GHG9210002) 2523-19, dated
03-04/12/2019
CT : CT0 (1HDG008100M0040) –
(2GHV981000 & 2GHV181600)

VT: PI0 (1HDG008100M0040)

Sub-supplier List: HE Doc. No.


12146632_Rev-AN, Dt: 13-08-2023

145kV HGIS type ELK-04, 145kV

10. 2 Page 291 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

(1HDG008100M0040) – same as GIS


and
Ratings: 145kV, 2400A@55°C 60Hz,
40kA (3s)/108kAp

Hitachi Power Systems Indonesia Walid Jufalli Corporation GIS: CFTA-145, 145kV, 3150A @40 ºC, 145kV GIS Type PQ letter:
(HPSI) (WJCO) 60HZ, 40kA (1s)/104kAp. CFTA with CB, Based on S&SD letter # 17-03689-03-30504401
Indonesia P.O Box#1380, Jeddah DS/ES & cable dated May 18, 2017, it is pre-qualified for 145kV
21493, Kingdom of Saudi Circuit Breaker: compartment has GIS Type CFTA with CB CFPTB-40LB, FAR3 as
Plant -Indonesia Arabia. CFPTB-120-40LB-FAR3, 145kV, 3150A successfully conforming to National Grid SA with specification
Mr. Yuichi Wakabayashi, @40 ºC, 60HZ, 40kA (1s)/104kAp with completed the type # 32-TMSS-02 with the following conditions:
EJIP Industrial Park Plot 8E, Cikarang +966 (12) 2637600 & spring charge operating mechanism tests in laboratories;
Selatan, Bekasi, 17750 Indonesia +966 500338276 type: “FA”. KERI – Korea during WARRANTY:
yuichi.wakabayashi@hit 25 July to 10 August •Ten (10) years extended Guarantee/warranty
Contact Person - Mr. Hendrawan, achi-td.com Busbar DS: CFL-EEA, 145kV, 3150A 2016 & Hitachi from the date of PAC of the project (in case of
Phone - Phone: +62-21-8970350, @40 ºC, 60HZ, 40kA (1s)/104kAp with Laboratory- Japan contract award) or date of delivery (in case of
Mobile: +62 815 11536388 operating mechanism type “CA”. during 14 November direct material supply order), as confirmed to
Email ID - to 17 December SEC/National Grid SA, through their Letter No #
[email protected] Line DS: CFL-EEA, 145kV, 3150A @40 2016 HPSI-BD/02/VIII/2014 R3 dated March 22, 2017.
d& ºC, 60HZ, 40kA (1s)/104kAp with
yoshikazu.hirotani@hitachipowersyste operating mechanism type “CA”.
ms.co.id
Contact Person Email ID - Mr. MS: CFL-EEA, 145kV, 60HZ, 40kA
Hendrawan, (1s)/104kAp with operating mechanism
Website - type “CA”.
http://www.hitachi.com/products/powe
r/TandD/location/index.html HSES: CFGM-FA, 145kV, 60HZ, 40kA
(1s)/104kAp with operating mechanism
type “MSG” Spring charged.

Cable compartment: CFTA

10. 2 Page 292 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE GRID GMBH GIS Type test completed Based on S&SD letter# 13-4433-01-30504401,
SWITZERLAND 145kV GIS type F35 with dated 16 January 2013, it is pre-qualified for
rated current, 3150A @40°C, 60Hz, 145kV GIS type F35 with rated current, 3150A
Plant -. @40°C, 60Hz, against specification #
CB type- F35-CB4 / Opr. 32-TMSS-02, Rev.1 with the following condition:
Oberentfelden Switzerland Mech: FK3-2 (spring charged),
CB Capability for: 1. Eight (8) years extended warranty from the
Inductive load switching: YES date of PAC of the first turnkey project (in case
of contract award) or from the date of first
Capacitor bank back to back Switching: delivery of direct material supply order. This was
YES confirmed through manufacturer lletter ref:
Q1F35_210409 dated 21 April 2009.
Line & Busbar DS-F35-DES-4/
Opr. Mech: ME1-3, Old Version:
145kV GIS type B65 with CB type B65-
MES-F35-DES-4/ Opr. Mech: ME1-3, Previously " Areva T &D AG,
SWITZERLAND-Oberentfelden ", the name has
HES-F35-EFZ/Opr. Mech:MF-3 (spring been changed to ALSTOM Grid AG,
charged), Oberentfelden, Switzerland, based on ALSTOM
Grid Letter # Nil dated July 11, 2012.
CT-F35-CT4, Previously " ALSTOM Grid AG Switzerland,
Oberentfelden ", the name has been changed to "
OLD GE Grid Switzerland GmbH,Oberentfelden ".
based on GE Grid letter # Nil dated June 01, 2016.
145kV GIS type B65

CB type B65-CB Motor spring


mechanism

DS type B65-DS

ES type B65-ES

HES type B65-EF

10. 2 Page 293 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES 145 kV GIS Type test was LATEST VERSION:
CORPORATION (HICO) LATEST VERSION conducted at Based on S&SD letter # 15-07077-01-30504401
SOUTH KOREA Type HSG-144D independent testing dated September 07, 2015, it is pre-qualified for
40kA, 2500A/ 3150 A labs like CESI- 145kV GIS Type
Plant -Republic of Changwon, Korea Italy,KERI – Korea, HSG-144D, 40 kA, 2500A/3150A
CB type HCSP-144D/ MELCO-Japan,
Eric Rhie, 450, Gongdeok-Dong, Opr. Mechanism HMSP-500 (spring HYOSUNG For latest WARRANTY
Mapo-Gu, Seoul , Korea charged); version Ten (10) years Extended Guarantee / Warranty
Tel:82-707-6180 from the date of PAC of the Project (in case of
CB Capability for: contract award) or from the date of delivery for
Contact Person - Mr. Jason Kang; Sale Inductive current switching: YES the direct material supply order. This is applicable
Manager & Mr. Young Kim; Sales Capacitor bank back to back switching: from first project and subsequently reduced
Manager YES yearly in case of future project. This was
Contact Person Email ID - confirmed, through their Letter No.SB/TDS/AK/
[email protected] , Busbar DS type 120 930/2100A dated 01/04/2013.
[email protected] HDMO-144D/ Opr. Mech: HM3P-710;
Website - Line DS type
http://www.hyosung.co.kr/eng/index.js HDMO-144C / Opr. Mech. HM3P-710;
p?, www.hyosung.com MES type HEMO-144C
/ Opr. Mech. HM3P-710; HES type
HEMS-144C / Opr. Mech.
HMMS-500 (Spring charged), Cable
compartment
type-HSG-144D

NEW VERSION Model Type HSG-144A


145KV GIS with CB type HCSP-144A
Motor spring mechanism;
CB Capability for:
Inductive load switching: YES
Capacitor bank back to back Switching:
YES

DS type HDMO-144A; MES type


HDMO-144A, HES type HEMS-144A

OLD VERSION: 145kV GIS type


145HGS40 with CB type
145HCB,145PL40; DS type
145SDSV/SDSH; MES type
145SESM; HES type 145SESA

10. 2 Page 294 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB AG NEW VERSION (TYPE ELK-04C ) NEW VERSION NEW VERSION (TYPE ELK-04C )
GERMANY Equipment designations & Ratings: (TYPE ELK-04C ) PQ letter:
a) GIS: ELK-04C, 145kV, 3150A @40 ABB, AG Germany Based on S&SD letter # 18-01225-2-30504401
Mannheim, Germany , Brown Boveri ºC, 60HZ, 40kA (3s)/108kAp. has successfully dated April 01, 2018, for ABB, AG Germany is
Street 30, 63457 Hannau, Germany completed type tests pre-qualified for 145 kV GIS Type ELK-04C as
b) Circuit Breaker: SD04 on 145kV GIS Type conforming to latest National Grid SA
Contact Person - Mr. Josef Hanson (2GHV010550M0001), 145kV, 3150A ELK-04C at specification # 32-TMSS-02, with the following
Email ID - [email protected] @40 ºC, 60HZ, 40kA (3s)/108kAp with Independent testing condition:
Website - http:// spring charge operating mechanism laboratories KEMA –
http://www.abb.de/cawp/deabb200/ea type: “MSD1 ((2GHV003600)” Netherland & PEHLA WARRANTY:
b4f33d72c264bec1256fb90037eeaa.as CB Capability: Inductive: YES, – Switzerland Ten (10) years extended warranty from the date
px Capacitor Bank: NO of PAC of the project (in case of contract award)
or date of delivery (in case of direct material
c) Busbar DS: TX04 supply order), as confirmed to SEC/National Grid
(2GHV010550M0001), 145kV, 3150A SA, through their Letter No #
@40 ºC, 60HZ, 40kA (3s)/108kAp with PGHV-180115/GIS-1, dated March 02, 2018.
operating mechanism type “DHS
(1HC0070676)”.
OLD VERSION (TYPE ELK-04 )
d) Line DS: TX04 PQ Letter: TS&SD letter # 11-00455-5-03032301
(2GHV010550M0001), 145kV, 3150A dated April 04, 2011, for new version 145kV GIS
@40 ºC, 60HZ, 40kA (3s)/108kAp with type ELK-04.
operating mechanism type “DHS
(1HC0070676)”. WARRANTY
Ten (10) years extended warranty/guarantee in
e) Maintenance ES: EM04 respect of defects due to design, manufacture,
(2GHV002340), 145kV, 60HZ, 40kA installation & workmanship from the date of
(3s)/108kAp with operating mechanism Provisional Acceptance Certificate (PAC) of the
type “DHS (1HC0070676)”. first turnkey project in case of contract award or
date of first delivery in case of direct material
f) High Speed Earthing Switch: EB04 supply order , as confirmed by the manufacturer
(2GHV006000), 145kV, 60HZ, 40kA through letter no. PTPH/GVS-Nb, 10, dt: 14th May
(3s)/108kAp with operating mechanism 2010.
type “EB04/2GHV006000)” Spring
charged. OLD VERSION
PQ Letter: DM # 011/63000/KB/168, dated
g) CT: CN04 (2GHV010550M0001) 18-08-1422 (H) prequalified GIS type ELK-04

h) VT: PI04 (2GHV010550M0001)

i) Cable compartment : HK04F


(2GHV010550M0001), 2500A @40 ºC,

10. 2 Page 295 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

60HZ, 40kA (3s)/108kAp.

OLD VERSION (TYPE ELK-04 )


Type/Model: ELK-04

Rating: 145kV, 2500A/ 3150A@ 40°C,


60Hz, 40kA(1s)/104kAp.

Circuit Breaker: ELK-CB0 (Hydraulic


Spring Mech. HMB-1.

CB Capability:
Inductive load switching: YES
Capacitor bank back to back Switching:
YES

DS type: ELK-DE0-3POS,

MES type: ELK-DE0

HSES type: ELK-ES0 (Motor Spring


Mech.)

OLD VERSION:
Type/ Model: ELK-04

CB type: ELK-SW04, Hydraulic spring


mechanism

DS type: ELK-TE0 (3 POS)

MES type: ELK-TE0 (3 POS)/


TE03-DR04

HES type: ELK-EB03.

10. 2 Page 296 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR HIGH VOLTAGE 145kV GIS GIS & ADAPTORS ONLY TO DTA.
SWITCHGEAR INC, Type/ Model: K8D.6
CROATIA PQ Letter: As per existing
Rating: 132kV
Plant -Zagreb/Croatia-Hrvatska
CB Capability:
Borongajska Cesta 81C 10000 Zagreb Inductive load switching: NO
Capacitor bank back to back Switching:
Contact Person - Mr. Toni Delić NO
Phone - +385 (0)99 2475 663, +385
(0)1 235 4606
Email ID - [email protected]
Website - http://www.koncareu.hr

10. 2 Page 297 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS INDUSTRIAL SYSTEM CO. 145kV GIS Type test completed PQ Letter:


KOREA, Republic of S&SD letter# 13-07921-2-30504401 dated
Type/ Model: GESG-1440NHS January 06, 2014,for 145kV GIS type
Plant -Cheongju Plant 1, GESG-1440NHS
Songjeong-Dong Heungdeok-Gu, Rating: 145KV, 3150A @40°C,
Cheongju-Si, 361-720, Republic Of 60Hz,40kA (3s)/ 104kAp WARRANTY:
Korea Ten (10) years extended warranty/guarantee in
CB type: GEDB-1440NHS / Opr. Mech. respect of defects due to design, manufacture,
Ls Industrial Systems Co., Head Office, Type: GGA204155 (spring charged) installation & workmanship from the date of
Seok-Won Jang, Sales Rep. Yeonsei Provisional Acceptance Certificate (PAC) of the
Jaedan Severance Bld; 84-11, CB Capability: first turnkey project in case of contract award or
Namdaemun-Ro-5Ga, Jung-Gu, Seoul, Inductive load switching: YES date of delivery in case of direct material supply
100-753, Republic Of Koreat&D Capacitor bank back to back Switching: order, as confirmed in writing by the
Business Division, Pre-Qualification YES manufacturer through their letter #Nil dated
Team, Ls Tower, 127, Ls-Ro, November 25, 2013.
Dongan-Gu, Anyang-Si, G LDS type: GESG 1440-ACSF/ Opr.
Mech: Motor
Contact Person - Mr. Je-woo, Lee
Phone - +82-2-2034-4541 BDS type: GESG 1440-ACSB / Opr.
+82-10-2711-6342 Mech:
Email ID - [email protected] Motor
Website - Web: http://www.lsis.com
MES type: GESG 1440-ACSB/ Opr.
Mech: Motor

HES type: GESG 1440-MSES /Opr.


Mech: Motor spring

CT: JK

10. 2 Page 298 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS AG, LATEST VERSION: Type test conducted LATEST VERSION:


GERMANY at KEMA Lab
145 KV 8DN8-5 , 40 kA 3150A,@40° Netherland & PEHLA Based on S&SD letter# 15-06390-02-30504401
Plant -Berlin C,60Hz Lab Germany for dated August 13, 2015, it is pre-qualified for
145 kV GIS type 145kV GIS type 8DN8-5 with rated current,
Freyeslebenstr. 1 91058 Erlangen, CB type- 8DN8-5 / Opr. Mech. Type: 8DN8-5 3150A, 60Hz,
Germany FA2 (spring charged),
CB Capability for: CONDITION: Nil
Contact Person - Mr. Yaser Salih , Inductive load switching: YES
Juergen Wolff Capacitor bank back to back Switching: WARRANTY
Phone - +49 9131 7 25216, +49 9131 7 No Ten (10) years extended warranty from the date
31625 Short line fault: Minimum 5.2m length of PAC of the first turnkey project in case of
Email ID - bus duct between feeder contract award or date of first delivery in case of
[email protected],Juergen.wol Bay and OHL shall be used in case the direct material supply order & subsequently
[email protected] bay is directly reduced yearly in case of future project, as
connected to OHL lines confirmed in writing by the manufacturer through
LDS type- 8DN8-5-3PS / Opr. Mech: their letter # Nil dated May 30, 2012.
Motor,
BDS type- 8DN8-5-3PS / Opr. Mech:
Motor,
MES type- 8DN8-5-ES / Opr. Mech:
Motor,
HES type- 8DN8-5-HES / Opr.
Mech:Motor spring

NEW VERSION
Type/Model: 8DN8-II

Rating: 145kV

CB type: 8DN8, Motor spring


mechanism

CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO

DS type 8DN8; ES type 8DN8.

OLD VERSION: 8DN8

10. 2 Page 299 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Rating: 145kV

CB type: 8DN6(P1), Motor spring


mechanism

CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO

DS type: 8DN8

ES type: 8DN8

FUJI ELECTRIC CO. 145kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
OLD VERSION letter # XAE-VR-121213, dated 13-12-2012 and
Type/ Model: SDA5 (SDA514), 145kV FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

CB type: BAK5, Hydraulic mechanism.

CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO

10. 2 Page 300 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MITSUBISHI ELECTRIC CORPORATION Yuji KOBAYASHI / 145kV GIS Type Test performed PQ letter:
JAPAN General Manager LATEST VERSION in Based on S&SD letter #18-03818-030504401
Power Transmission & Type/Model: 100-GMKD-1 KERI, Korea # dated October 30, 2018, Mitsubishi Electric,
Plant -T&D Systems Center, Amagasaki Distribution Division, Rating 145kV, 3150A@40 ºC, 2017TC00557, dated Japan is pre-qualified for 145 kV GIS type
City, Japan MITSUBISHI ELECTRIC 60Hz,40kA (3s)/ 104kAp 15-17/03/2017, 100-GMKD-1 as conforming to latest National Grid
SAUDI, LTD. P.O. box: CB type: 120-SFMT-40CJ, 145kV, KERI, Korea # SA specification # 32-TMSS-02, with the
Mitsubishi Electric Corporation, Tdsc, 2391, Riyadh 11451 3150A@40 ºC, 60HZ, 40kA 2017TC00559, dated following conditions:
Marketing Department, 8-1-1 +966 11 477 7947 (3s)/104kAp. Operating mechanism: 08-09/03/2017,
Tsukaguchi-Honmachi, Amagasaki City, (Ext.260) / +966 55 547 BM-J4 (spring motor charged) KERI, Korea # WARRANTY:
Hyogo, 661-8661, Japan 5316 CB Capability: 2017TC00085, dated Ten (10) years extended warranty/guarantee
[email protected] Inductive load switching: YES 20/03-16 to from the date of (PAC) of the Turnkey project (In
Contact Person - Mr. Yohei Okada a.com.sa Capacitor bank back to back Switching: 26-07-17, case of contract award) and from the date of
Phone - +81-6-6497-8288 YES KERI, Korea # delivery for the direct material supply order. The
Email ID - BDS /LDS type: 120-GRD, 3150A@40 2017TC00468, dated guarantee/warranty shall be applicable from first
[email protected]. ºC, 60HZ, 40kA (3s) /104kAp, 21-03-2017, project and shall cover all the cost of materials
jp Operating mechanism: MDE and labor as per warranty/guarantee of materials
Website - MES type: 120GRED, 40kA (3s) KEMA, Netherland # and workmanship and subsequently reduced
http://global.mitsubishielectric.com/ /104kAp , Operating mechanism: MDE 2049-18, dated 1-23 yearly in case of future project award. This was
HES type: 120-GRE-A, 40kA(3s) Feb to 09-14 March confirmed in writing by Mitsubishi Electric, Japan
/104kAp Operating mechanism: MBE 2018, through their letter # Nil dated July 08, 2018.
(spring motor charged) KEMA, Netherland #
Cable compartment: H60F392, 2050-18, dated 28
3150A@40 ºC, 60HZ, 40kA (3s) Feb to 02 March
/104kAp 2018, -ORIGINALLY TMT&D CORP. & DISSOLVED
KEMA, Netherland # DURING APRIL 2005.
2051-18, dated 1-23
145kV GIS Feb to 09-05 March
NEW VERSION 2018,
Type/Model: 100GMKD
Mitsubishi, Japan #
Rating 145kV, 60Hz,40kA (xs)/ 104kAp HKT-29504, dated
CB type: 120-SFMT-40CJ 23-24/01/2017,
CB Capability: Mitsubishi, Japan #
Inductive load switching: YES HKT-29474, dated
Capacitor bank back to back Switching: 10/11/2017,
NO Mitsubishi, Japan #
DS type: 120GRD/GLD HKT-29530, dated
MES type: 120GRED/GRE 04-08/08/2017,
HES type: 120 GRED/GRE-A Mitsubishi, Japan #
HKT-29472, dated
OLD VERSION: 26-30/09/2016,
Type/Model: 120GMKM Mitsubishi, Japan #

10. 2 Page 301 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HKT-29475, dated
Rating: 145kV 15-30/09/2016,
CB type: 120-SFMT-40, Pneumatic Mitsubishi, Japan #
mechanism HKT-29470, dated
DS type 120-GR-20, 120-GL-20 24/08-13/09/2016,
MES type: 120-GRE, 120-GREC Mitsubishi, Japan #
HES type: 120-GREA HKT-29478, dated
07-08/11/2016,
OLD VERSION: Mitsubishi, Japan #
Type/ Model: 100GMKD HKT-28699, dated
Nil,
Rating:145kV, Mitsubishi, Japan #
CB type: 120-SFMT-40CE, Motor spring HKT29397, dated
mechanism 13-01-2015,
DS type: 120GLD Mitsubishi, Japan #
HES type: 120-GREA HKT29398, dated
13-01-2015,
Mitsubishi, Japan #
HKT29397, dated
13-01-2015,
Mitsubishi, Japan #
HKT-28699-A, dated
13-01-2015,
Mitsubishi, Japan #
HKT-29346, dated
08-06-2013,
Mitsubishi, Japan #
HKT-29365, dated
5-08- 2013,
Mitsubishi, japan #
HKT-29510-A, dated
20-24 June, 2013

10. 2 Page 302 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HITACHI LTD 145kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN NEW VERSION: subsequent change affected as per HITACHI
Type/ Model: CFTA letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
Rating: 145kV,
Akihabara Daibiru Building, 18-13, NEW VERSION:
Soto-Kanda 1-Chome, Chiyoda-Ku, CB type: CFPT-120-40L, FAR3 Motor PQ Letter:
Tokyo, 101-8608, Japan spring mechanism MD # 011/63000/KB/169, dated 18-08-1422 (H),
pre-qualified GIS type CFTA.
Contact Person - Mr. Masaharu Tsumori CB Capability:
Phone - +81-3-4564-4741 Inductive load switching: NO
Email ID - Capacitor bank back to back Switching:
[email protected] NO
Website - http://www.hitachi.com
DS type: CFL-120

ES type: CFL-120

OLD VERSION
Type/ Model: CFT

Rating: 145kV

CB type: CFPT-140-40L, FAR3,C


Pneumatic mechanism

DS type: SFL-EA

HES type: SFGM-FA

10. 2 Page 303 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TOSHIBA CORPORATION, T&D 145kV GIS Type Tested at ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN Toshiba lab during DURING APRIL 2005.
NEW VERSION 25th March to 12th 2005.
Website - April 204 & 18th to
http://www.toshiba.co.jp/index j3.htm GIS Type 20th Aug 2014 and NEW VERSION
G3A-b with CB type GSPK-145FPW / repeated internal arc
Opr. Mechanism tests in KEMA PQ Lettter
GSPK-145FW (spring charged); Netherland during Based on S&SD letter # 15-09018-2-30504401
CB Capability for: 8th to 10th April dated November 10, 2015, it is pre-qualified for
Inductive current switching: YES 2015 & 10th to 12th 145kV GIS Type
Capacitor bank back to back switching: June 2015. G3A-b, as conforming to National Grid SA
YES Report Nos. specification # 32-TMSS-02,
2238-15,30-07,29-0
Busbar DS type DAM-145W2 / 7,27-07, WARRANTY
Opr. Mech: DAM; Line DS type Ten (10) years Extended Guarantee / Warranty
DBM-145W2 / Opr. Mech. DBM; from the date of PAC of first Project (in case of
MES type EBM-145W2 / Opr. Mech. contract award) or from the date of first delivery
EBM; for the direct material supply order. This was
HES type confirmed, through their Letter No. TSB/TDS/AK/
EAP-145W2 / Opr. Mech. EAP (Spring 120930/2100A dated 01/04/2013.
charged)

OLD VERSION
Type/ Model:
Rating: 145kV

CB type: GSPK-145AP

CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO

BDS type: KTM-120PW, DTM-120PW,


DLM-120PW

LDS type: KTM-120PW, DTM-120PW

MES type: EBM-120W

HES type: EAP-120W.

10. 2 Page 304 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS GIS Type test completed GIS from Siemens, Germany


FRANCE New version: Based on S&SD letter # 15-9615-30504401 dated
145kV GIS type TH7m December 16, 2015 and Siemens letter # Nil,
Plant -Grenoble, France dated May o5, 2015, 145KV
CB type TH7m AF8ER(Motor GIS type 8DN8-II incorporated under Siemens,
Siemens S.A.S., 2 rue de la Neva - BP spring) France with
178 38004 Grenoble, France CB Capability for: following conditions:
Inductive load switching: NO
Contact Person - Lyons Laurent Capacitor bank back to back Switching: • Ten (10) years extended warranty from the
Contact Person Email ID - NO date of PAC of turnkey project in case of contract
[email protected] award or from date of delivery in case of direct
BDS type CM002, CM003 (3-position) material supply order. This is
applicable from first project and subsequently
LDS type reduced yearly in case of future project. This
CM002, CM003 (2-position) was confirmed by the manufacturer through
letter #Nil, dated November 04, 2015
MES type CM002,CM003; HES
type CM002, CM003.

• Old version:
145kV GIS type HEXABOLIC-TH7

CB type
DTH7 Hydraulic mechanism

BDS type SITH7

LDS type ITH7,


SI TH7

ES type ST TH7.

145kV GIS type 8DN8-II

CB type 8DN8 Motor spring Mechanism

DS type 8DN8

ES type 8DN8.

Total = 16

10. 2 Page 305 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SWITCHGEAR
10. 3
SF6 GAS INSULATED SWITCHGEAR & HYBRID SF6 GAS INSULATED SWITCHGEAR 230kV Applicable Standards: 32-TMSS-02

GE Grid Solution SAS (GE & Alstom 245kV GIS Previously ALSTOM GRID SAS, FRANCE, the
Joint Venture) name has been changed to GE Grid Solutions /
FRANCE Type/Model: B105 GE & ALSTOM joint Venture - Francebased GE
Grid Solutions / GE & ALSTOM joint Venture letter
Plant -Aix-Les Bains, France Rating: 245kV # Nil, dated October 13, 2016.

GE Grid Solution SAS (GE & Alstom CB type: B105-CB


Joint Venture), 1, Rue Paul Doumer Previously "AREVA T&D– FRANCE-(AIX-LES
73100 Aix-Les-Bains (France) CB Capability: BAINS) ", the name has been changed to
Inductive load switching: xx ALSTOM Grid SAS-France based on ALSTOM
Aix-Les Bains Capacitor bank back to back Grid-France letter # Nil, dated December 07,
Switching:xx 2012.
Contact Person - Mr. Zinedine RABAH
Phone - +33(0) 4 79 88 79 80 + 971 4 DS type: CLT
4299 651

10. 3 Page 306 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Switzerland Ltd. 245kV GIS Mfr. Name change from ABB Switzerland Ltd to
SWITZERLAND NEW VERSION Hitachi Energy Switzerland AB
Type / Model: ELK-14/300
Toto Building, Brown Boveri Strasse 5 1HC0071250M0040) PQ Letter:
8050, Zurich, Switzerland S&SD letter # 14-00064-30504101 dated January
Rating: 245kV, 4000A, 40°C, @ 60Hz, 26, 2014 and ABB Letter # PPHV-300GIS CH-05
Contact Person - MR. Dieter 63kA(1s)/163.8kAp dated February 02, 2014 the designation has
Fuechsle(Global Qualification and been corrected.
Certification Manager for GIS.), Mr. CB Type: ELK-SP14/300
Abdulmajeed Alothman (1HC0071250M0040) / Opr. Mech: CONDITION:
Email ID - HMB4 (1HC0071250M0040) Capacitor Bank Back to Back switching type test
[email protected], will be performed when required in the project,
[email protected] confirmed by ABB letter # PPHV-140120/GIS-1,
om dated 21-01-2014.
Contact Person Email ID - CB Capability:
[email protected], Inductive load switching: xx
[email protected] Capacitor bank back to back Switching:
om No
Website - www.hitachienergy.com
LDS & BDS Type: ELK-TK14/300
(1HC0071250M0040) / Opr. Mech: BAC
(1HC0071250M0040)

MES Type: ELK-TK14/300


(1HC0071250M0040) / Opr. Mech: BAC
(1HC0071250M0040)

HES Type: ELK-EB14/300


(1HC0071250M0040) / Opr. Mech: BAE
(1HC0071250M0040)

CT Type: ELK-CN14/300
(1HC0071250M0040)

Cable compartment Type:


ELK-HK 14/300 (1HC0071250M0040)

OLD VERSION
Type/ Model: ELK-1
Rating: 245kV
CB Type: ELK SP2-1.

10. 3 Page 307 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FUJI ELECTRIC CO. 245kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/Model: letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
CB:

CB Capability:
Inductive load switching: xx
Capacitor bank back to back Switching:
xx

MITSUBISHI ELECTRIC CORPORATION 245kV GIS ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Type / Model: 200GPS
Plant -T&D Systems Center, Amagasaki
City, Japan Rating: 245kV

Mitsubishi Electric Corporation, Tdsc, CB:


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City, CB Capability:
Hyogo, 661-8661, Japan Inductive load switching: xx
Capacitor bank back to back Switching:
Contact Person - Mr. Yohei Okada xx
Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

10. 3 Page 308 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HITACHI LTD 245kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type / Model: MFPT MFPTB-300-63L letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
Rating: 245kV
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, CB type: MFPTB-300-63LA,
Tokyo, 101-8608, Japan HAR/MFTB-300-563L

Contact Person - Mr. Masaharu Tsumori CB Capability:


Phone - +81-3-4564-4741 Inductive load switching: xx
Email ID - Capacitor bank back to back Switching:
[email protected] xx
Website - http://www.hitachi.com
BDS type: FL-EA

LDS type: FMG-FA/FG

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

10. 3 Page 309 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS 245kV GIS PQ Letter:


GERMANY S&SD letter # 13-05708-1-30504401, dated
Type/ Model: 8DN9 October 10, 2013 for 245kV GIS type 8DN9
Plant -Berlin
Rating: 245kV, 3150A @40°C, 60Hz, CONDITION:
Siemens Ag Freyeslebenstr. 1 91058 50kA(1s)/130kAp CB capability for Capacitor bank back to back
Erlangen, Germany switching (BC1/BC2) is applicable for 145kV
CB type: 8DN9-245kV-50kA/Opr. Mech: only.
Contact Person - Mr. Yaser Salih spring charged
Juergen Wolff WARRANTY:
Phone - +49 9131 7 25216, +49 9131 7 CB Capability: Ten (10) years extended warranty/guarantee in
31625 Inductive load switching: xx respect of defects due to design, manufacture,
Email ID - [email protected] Capacitor bank back to back Switching: installation & workmanship from the date of
400A for 132kV application Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Line & Busbar type: date of delivery in case of direct material supply
DS-8DN9-245kV-50kA/Opr. Mech: order, as confirmed in writing by SIEMENS,
Motor Germany-Berlin through their letter # Nil dated
June 19, 2010.
MES-8DN9-245kV-50kA/Opr. Mech:
Motor PQ Letter:
TS&SD letter # 11-00267/01-03032301 dated
HES-8DN9-245kV-50kA/Opr. Mech: 02/02/2011, for 300kV GIS type 8DN9
spring charged
CONDITION:
Type/Model:8DN9-300kV This GIS shall only be used for 245kV, 63kA
applications.
Rating: 300kV, 4000A@40°C, 60Hz,
63kA(1s)/164kAp WARRANTY:
Ten (10) years extended warranty/guarantee in
CB (Single Break) type: respect of defects due to design, manufacture,
8DN9-300-63-4000 with motor spring installation & workmanship from the date of
mechanism Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
CB Capability: date of delivery in case of direct material supply
Inductive load switching: xx order, as confirmed through SIEMENS letter #
Capacitor bank back to back Switching: PQ_8DN9_02 dated 26/06/2010..
xx
OLD VERSION
Busbar & line DS type:
8DN9-300-63-4000 with motor drive Based on SIEMENS letter# 30179023-A1 dated
mechanism 02/05/2011, this type 8DN40-DN4) is already

10. 3 Page 310 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

obsolete/ phased out.


MES type: 8DN9-300-63-with motor
drive mechanism

HES type: 8DN9-300-63-4000 with


motor drive mechanism

SIEMENS Type / Model:


FRANCE

Plant -Grenoble, France

Siemens S.A.S., 2 rue de la Neva - BP


178 38004 Grenoble, France

Contact Person - Lyons Laurent


Contact Person Email ID -
[email protected]

Total = 8

SWITCHGEAR
10. 4
SF6 GAS INSULATED SWITCHGEAR & HYBRID SF6 GAS INSULATED SWITCHGEAR, 380 KV Applicable Standards: 32-TMSS-02

10. 4 Page 311 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens High Voltage Switchgear Co., Siemens Energy Limited 420kV GIS/HGIS type 8DQ1 PQ Letter
Ltd. Shanghai Saudi Arabia Based on S&SD letter #22-008282/03-30504401
CHINA Business Gate, Building Ratings: GIS- 420kV, 4000A@40°C, dated 17-05-2023, the manufacturer is
C-1, 60Hz, 63kA (3s)/164kAp prequalified for 420kV GIS and 420kV HGIS type
Plant -Shanghai, P.R. China Airport Road, Qurtubah HGIS- 420kV, 3150A@55°C, 8DQ1 as confirming to National Grid SA
District. 60Hz, 63kA (3s)/164kAp specification # 32-TMSS-02, with the following
No. 299 Tian Ning Road, Min Hang P.O. Box 39582, Riyadh conditions:
District, Shanghai, P.R. China 11489, CB: 8DQ1: 420kV, 4000A@40°C, 60Hz,
Saudi Arabia 63kA (3s)/164kAp TYPE TEST:
Shanghai 00966566375966 CB Opr. Mech: FA5 (spring type) Fresh Type Tests shall be conducted in an
kaisar.langoo@siemens- independent testing laboratory in the presence of
Contact Person - 1rst Contact: Mr. Xu energy.com CB capability: Inductive load switching: (03) SEC/National Grid SA representatives and
Feng Yu- Stan 2nd Contact: Mr. Cai Chi YES one approved third party inspector during first
Xiang- Jason Capacitor bank back to SEC/ National Grid SA project/ order and all cost
Phone - +86 (21) 24085606 back switching: NO pertaining to tests shall be borne by the
Email ID - manufacturer. This has been confirmed in writing
[email protected] Busbar & Line DS: by the manufacturer through letter #
Contact Person Email ID - 1st Contact: 8DQ1-DS-4000A@40°C, 60Hz, 63kA SHVS230406KSAPQ01, dated 06 April, 2023.
[email protected] 2nd (3s)/164kAp, Opr. Mech:
Contact: 8DQ1-DS-47557139
[email protected] WARRANTY:
Website - www.siemens-energy.com MES: 8DQ1-6 ES- 60Hz, 63kA Ten (10) years extended warranty/guarantee to
(3s)/164kAp, Opr. Mech: SEC/National Grid SA for the offered 420kV
8DQ1-ES-47557142 GIS/HGIS type 8DQ1 in respect of the defects
due to design, manufacturing, installation and
HES: 8DQ1-6HSES- 60Hz, 63kA workmanship from the date of Provisional
(3s)/164kAp, Opr. Mech: Acceptance Certificate (PAC) of the first turnkey
8DQ1-HSES-47557187 project (in case of contract award) or from the
date of first delivery (in case of direct material
VT: 8DQ1 supply order), as confirmed by the manufacturer,
through their Letter Ref. # SEC Bulk Tender
Prequalification, dated February 18, 2022.

10. 4 Page 312 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd HYBRID: HYBRID: HYBRID:


SOUTH KOREA Hybrid GIS Type: 550SR/2016, 420kV, Tests performed at: PQ letter:
4000A@55 ºC, 60HZ, 63kA (3s). CESI # B5003626-1 Based on S&SD letter # 18-02107-01-30504401
Plant -Ulsan in 2015/ KEMA # dated May 10, 2018, Hyundai Electric & Energy
CB: 550SR-K/2016, 4000A@55 ºC, 2127-15 in 2015 / Systems Co. Ltd. – Korea is pre-qualified for
1000, Bangeojinsunhwan-doro, 60Hz, 63kA (3s)/163.8kAp, Operating KERI # 420kV HYBRID SF6 Gas Insulated Switchgear as
Dong-gu, Ulsan, South Korea, mechanism: HA-4, Hydraulic; 2014TC00684in conforming to latest National Grid SA
2014 / 2016TC specification # 32-TMSS-02, with the following
Ulsan CB capability: 00638 in conditions:
Inductive switching: YES, Capacitor 2016/2017TC00614
Contact Person - Mr. J.W(Jin) Lee Back to back switching: YES in 2017 / WARRANTY:
Phone - +966-11-293-2026, 2018TC0015 in 2018 Ten (10) years extended warranty/guarantee in
+82-10-4818-0822 DS: BDS type 550DRM2/2016, LDS / MELCO # respect of defects due to design, manufacture,
Contact Person Email ID - type-550 DRM1/2016, 4000A@55 ºC, C10-I4F35 in 2014. installation & workmanship from the date of
[email protected] 60HZ, 63kA (3s) /163.8kAp, Operating Provisional Acceptance Certificate (PAC) of the
Website - mechanism: MMF-4 (for both DS). first turnkey project in case of contract award or
http://www.hyundaielectric.com date of delivery in case of direct material supply
MES: 550ERM/2016, 63kA (3s) New Version: order, as confirmed in writing by Hyundai Electric
/163.8kAp , Operating mechanism: Tests performed at: & Energy Systems Co. Ltd. – Korea through their
MMF-5. CESI # B5003626-1 letter # S350-20180201-3 dated February 01,
in 2015/ KEMA # 2018.
HSES: 550 LES/2016, 63kA(3s) 2127-15 in 2015 /
/163.8kAp Operating mechanism: KERI #
MSF-4 (spring charged). 2014TC00684in New Version:
2014 / 2016TC PQ letter:
Cable compartment: CH-550SR/2016 , 00638 in 2016/ Based on S&SD letter # 18-0728-02-30504401
4000A@55 ºC, 60HZ, 63kA (3s) 2017TC00614 in dated March 06, 2018, Hyundai Electric & Energy
/163.8kAp. 2017 / 2018TC0015 Systems Co. Ltd. – Korea is pre-qualified for
in 2018 / MELCO # 420kV GIS Type 550SR/2016 as conforming to
Current transformer: CT-550SR/2016. C10-I4F35 in 2014. latest National Grid SA specification #
32-TMSS-02, with the following conditions:
New Version:
Switchgear: 550SR/2016, 420kV, WARRANTY:
4000A@55 ºC, 60HZ, 63kA (3s). Old version: Ten (10) years extended warranty/guarantee in
Tests performed at: respect of defects due to design, manufacture,
CB: 550SR-K/2016, 4000A@55 ºC, Electro technology installation & workmanship from the date of
60Hz, 63kA (3s)/163.8kAp, Operating Research Institute, Provisional Acceptance Certificate (PAC) of the
mechanism: HA-4, Hydraulic; Korea # first turnkey project in case of contract award or
W2006003-K24-0.1/ date of delivery in case of direct material supply
CB capability: 12-10-2007, KERI order, as confirmed in writing by Hyundai Electric
Inductive switching: YES, Capacitor #2007TC00575/15-1 & Energy Systems Co. Ltd. – Korea through their
Back to back switching: YES 0-2007, KERI # letter # 20180226-1 dated February 26, 2018.

10. 4 Page 313 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

2007TC00603/09-04
DS: BDS type 550DRM2/2016, LDS -2007, KEMA #
type-550 DRM1/2016, 4000A@55 ºC, 56-07/ 23 Feb-4 May Old version:
60HZ, 63kA (3s) /163.8kAp, Operating 2007. PQ Letter:
mechanism: MMF-4 (for both DS). TS&SD Letter # 08-01807-03032301, Dated 16
July, 2008 for 380kV GIS.
MES: 550ERM/2016, 63kA (3s)
/163.8kAp , Operating mechanism: CONDITION:
MMF-5. Back to back capacitor switching test for C.B.
shall be done in independent laboratory in the
HSES: 550 LES/2016, 63kA(3s) presence of SEC Engineers whenever there is a
/163.8kAp Operating mechanism: requirement for this test in the PTS of forthcoming
MSF-4 (spring charged). SEC projects.

Cable compartment: CH-550SR/2016 , WARRANTY:


4000A@55 ºC, 60HZ, 63kA (3s) Ten (10) years extended warranty/guarantee in
/163.8kAp. respect of defects due to design, manufacture,
installation & workmanship from the date of
Current transformer: CT-550SR/2016. Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
Old version: order.
420kV GIS

Type/ Model: 550 SR -Previously Hyundai Heavy Industries Co. Ltd


[The name has been changed based on P&SFD
Rating: 420kV, 4000A @40°C, 60Hz, letter #17-04234/01-030504401 dated May 24,
63kA(3s)/170kAp 2017].

CB-550 SR-K: (Single Break) Previously Hyundai Electric & Energy Systems
Co., Ltd., the name has been changed to HD
CB Capability: Hyundai Electric Co., Ltd
Inductive load switching: xx YES
Capacitor bank back to back
Switching:xx NO

DS-550 DRM 1&2

ES-550 ERM

HES-550 LES

10. 4 Page 314 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB 420kV GIS PQ letter:


SWITZERLAND Type/ Model: ELK-3C 420kV Based on S&SD letter # 17-05539-2-30504401
(1HC0071250M0080) dated August 03, 2017, ABB – Switzerland is
Plant -Toto Building, Brown Boveri pre-qualified for 420kV GIS as conforming to
Strasse 5 8050, Zurich, Switzerland Rating: 420kV, 4000A @40°C, 60Hz, National Grid SA with specification # 32-TMSS-02
63kA(3s)/164kAp Rev.02 with the following conditions:
Contact Person - Mr. Klaus Lohse
Contact Person Email ID - CB: ELK- SP3-1 (1HC0071250M0080) WARRANTY:
[email protected] (Single break), 420kV, 5000A @40°C, • Ten (10) years extended warranty/guarantee in
Website - http://www.abb.ch/ 60Hz, 63kA(3s)/164kAp, Operating respect of defects due to design, manufacture,
Mechanism- HMB-4.3 Hydraulic installation & workmanship from the date of
spring Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
CB Capability: date of delivery in case of direct material supply
Inductive load switching: Yes order, as confirmed in writing by the
Capacitor bank back to back Switching: manufacturer through their letter #
Yes PHGV-170112/GIS-1 dated January 12, 2017.

Bus DS: TX3 (1HC0071250M0080),


420kV, 5000A @40°C, 60Hz,
63kA(3s)/164kAp Opr. Mech: DHS,

Line DS: TY3 (1HC0071250M0080) ,


420kV, 5000A @40°C, 60Hz,
63kA(3s)/164kAp Opr. Mech: DHS,

MES: EM3 (1HC0071250M0080), Opr.


Mech: DHS,

HES: EB3 (1HC0071250M0080), Opr.


Mech: DBS,

CT: CN3 (1HC0071250M0080),

VT: PI3 (1HC0071250M0080),

Cable compartment: HK3


(1HC0071250M0080), 420kV, 3150A
@40°C, 60Hz, 63kA(3s)/164kAp

10. 4 Page 315 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. Type of GIS: ELK-3/420 The type test were Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia (1HC0071250M0070) performed in 2021 & and changed to Hitachi Energy Ltd.
2022 at PEHLA &
Plant -Dammam Ratings: 420kV / 60Hz /3150A@55˚ KEMA Testing PQ Letter
C/63kA (1s)/163.8kA laboratories, Based on S&SD letter # MPQ77694310 dated
PO: 41022, Street 39 cross 144, 2nd following are the March 29, 2021, manufacturer is prequalified for
Industrial City, Dammam 31521, Saudi Designations: type test reports: SF6 GAS INSULATED SWITCHGEAR 420KV, as
Arabi CB: SP3-1(1HC0071250M0080)- Single PEHLA # 21054Ba, confirming to National Grid SA specification #
break with Opr. Mech: HMB4 PEHLA # 22062Ba-1, 32-TMSS-02, with the following conditions:
Dammam (1HC0071250M0080 / SP3 PEHLA # 22062Ba-3,
(1HC0071250M0070)- Double break PEHLA # 22062Ba-4 Type Tests
Contact Person - Abdulmajeed with Opr. Mech: HMB8 , PEHLA # 21061Ba, Confirmation / commitment as per ABB letter #, Nil,
Alothman ; Mr. Abdullah Hamidaldin ; (1HC0071250M0070) PEHLA # 21055Ba-0, dated 11.03.2021 to conduct the type tests at the
Mr. Jochen Kiefer PEHLA # 22051Ba, earliest or in case of failure of any type tests or
Phone - +966 11 2181703; +966 Rating: 3150A@55˚C/63kA PEHLA # 21124Ba, incompletion of the type tests, they shall supply
500414555 (1s)/163.8kA PEHLA # 22053Ba, the required equipment from SEC/National Grid SA
Email ID - ABB # 1HC0134336, approved Manufacturers.
[email protected] CB Capability of SP3-1 & SP-3: PEHLA # 18036Ba-2,
m; Inductive load switching: Yes PEHLA # 17040Ba, WARRANTY
[email protected] Capacitor bank back-to-back KEMA # 2188-21, Ten (10) years extended warranty from the date
m; [email protected] Switching: Yes KEMA # 2317-21, of PAC of the first turnkey project (in case of
KEMA # 2188-21, contract award) or date of first delivery (in case
BDS/LDS/MES: KEMA # 2318-21, of direct material supply order), as confirmed,
TK3/420(1HC0071250M0070) with Opr. KEMA # 2190-21, through their Letter No. Nil, dated June 23, 2019
Mech: BAC/Drawing 1HC0027461 KEMA # 2187-21, shall be applicable for the equipment to be
PEHLA # 21081Ba, supplied to SEC/National Grid SA.
HES: EB3/420(1HC0071250M0070) PEHLA # 21067Ba,
with Opr. Mech: BAE/Drawing PEHLA # 21065Ba,
1HC0024638 PEHLA # 21123Ba PQ Letter
Based on S&SD letter # 23-00742-30504401
CT: CN3(1HC0071250M0070) dated April 17, 2023, the manufacturer is
VT: PI3(1HC0071250M0070) prequalified for Hitachi Energy Ltd- Dammam,
Cable box: HK3(1HC0071250M0070) 380kV HGIS type ELK-3, 420kV
SF6 to Air Bushing: (1HC0071250M0070), as confirming to National
HD3(1HC0071250M0070) Grid SA specification # 32-TMSS-02, with the
SF6-oil termination: following conditions:
HT3(1HC0071250M0070)
Surge Arrester:
AZ3(1HC0071250M0070) WARRANTY
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered 380kV
HGIS type: ELK-3, 420kV Hybrid GIS (HGIS type ELK-3, 420kV

10. 4 Page 316 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

(1HC0071250M0070), 4000A at 55oc, (1HC0071250M0070) in respect of the defects


60Hz, 63kA (1s)/163.8kAp due to design, manufacturing, installation and
workmanship from the date of Provisional
CB: SP3-1 (1HC0071250M0070) – Acceptance Certificate (PAC) of the first turnkey
Single break & SP3 project (in case of contract award) or from the
(1HC0071250M0070) Double break- date of first delivery (in case of direct material
4000A at 55 oc, 60Hz, 63kA supply order), as confirmed by the manufacturer,
(1s)/163.8kAp through their Letter Ref. #
CB Opr. Mech: Hydraulic HV-AO/17-01-2023/001, dated January 17, 2023.
spring-SP3-1:HMB-4.2/HMB-4.3 &
SP3:HMB-8.2/HMB-8.3

CB capability: Inductive load switching:


YES
Capacitor bank back to back switching:
YES

Busbar & Line DS:


ELK-TK3/420(1HC0071250M0070) -
4000A@55°C, 60Hz, 63kA
(1s)/163.8kAp, Opr. Mech: ELK-BAC
(1HC0071250M0070) (Electronic /
Electronic free)

MES:
ELK-TK3/420(1HC0071250M0070) -
63kA (1s)/163.8kAp, Opr. Mech:
ELK-BAC (1HC0071250M0070)
(Electronic / Electronic free)

HES:
ELK-EB3/420(1HC0071250M0070) -
63kA (1s)/163.8kAp, Opr. Mech:
ELK-DBX or ELK-BAE
(1HC0071250M0070)

CT: ELK-CN3 (1HC0071250M0070)

VT: ELK-PI3(1HC0071250M0070)

Cable Sealing End: HK3


(1HC0071250M0070)

10. 4 Page 317 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

OHL termination: ELK-HD3 –for


porcelain Bushing or HB3
(1HC0071250M0070)- for composite
bushing

SF6-oil termination: ELK-HT3


(1HC0071250M0070)

10. 4 Page 318 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE Grid Solution SAS (GE & Alstom GIS Type test completed Previously "AREVA T&D– FRANCE-(AIX-LES
Joint Venture) 420kV GIS type T155 FOR NEW TYPE: GE BAINS) ", the name has been changed to
FRANCE CB type T155, FB2T (Hydraulic Mech.) Grid Solution SAS ALSTOM Grid SAS-France based on ALSTOM
(GE & Alstom Joint Grid-France letter # Nil, dated December 07,
Plant -Aix-Les Bains, France FOR NEW TYPE: Venture) – France 2012, and again the name has been changed to
GIS: T155-420kV (Mono), 3150A @ 40° has successfully GE Grid Solution SAS (GE & Alstom Joint
GE Grid Solution SAS (GE & Alstom C , 60Hz , 63kA(1Sec) completed type tests Venture) -France based on their letter # Nil, dated
Joint Venture), 1, Rue Paul Doumer Circuit breaker: T155-CB3, 3150A@40° on 420kV GIS Type October 13, 2016.
73100 Aix-Les-Bains (France) C, 60HZ, 63kA (1s), T155- 420KV
Operating mechanism:FK3-6 (Mono) at FOR NEW TYPE:
Aix-Les Bains BDS/LDS: T155-DS3, 3150A@40°C, Independent testing PQ letter:
60HZ, 63kA (1s), laboratories; CREDA Based on S&SD letter # 18-01638-01-30504401
Contact Person - Mr. Zinedine RABAH Operating mechanism: ME2-2 or ME4 - France, KEMA – dated April 17, 2018, for GE Grid Solution SAS
Phone - +33(0) 4 79 88 79 80 + 971 4 MES: T155-ES3, Netherland & CESI – (GE & Alstom Joint Venture) – France is
4299 651 Operating mechanism: ME2-2 or ME4 Italy. pre-qualified for GIS Type T155- 420kV (Mono)
HES: T155-EF3, Operating mechanism: as conforming to latest National Grid SA
ME2-2 (spring charged) or ME4 ME4 DS/ES Opr. specification # 32-TMSS-02.
Cable compartment: T155, , Mechanism Type
3150A@40°C, 60HZ tests: CERDA # WARRANTY:
Current transformer: T155-CT3 8143-2, dated Ten (10) years extended warranty/guarantee
Bus duct: T155-420kV: 3150A@55°C, 09/06/2015, CERDA from the date of Provisional Acceptance
60HZ, 63kA (1s) # 8143-3, dated Certificate (PAC) of the first turnkey project in
09/06/2015, GE # case of contract award or date of first delivery in
2019-069, dated case of direct material supply order, as
18/10/2019, RUAG # confirmed to SEC/National Grid SA, through their
Hybrid GIS: 7169, dated letter # BHT14032017, dated March 14, 2017.
420kV GIS type T155 Mono with its 24/01/2014.
components up to current rating
3150A, @55 ͦC, 60Hz PQ letter (ME4):
Hybrid GIS: Based on S&SD letter # 19-01461-01-30504401
Type test completed dated November 26, 2019, ME4 Operating
for Hybrid GIS as Mechanism for 420kV DS/MES/HES is accepted
indicated in GIS Type for GE Grid Solution SAS (GE & Alstom Joint
T155 Mono. Venture) – France for the pre-qualified GIS Type
T155- 420kV (Mono).
For SF6-Air
Bushing; CERDA #
10113_1/17-22/06/2 WARRANTY (ME4 Opr. Mech.):
020 & Ten (10) years extended warranty/guarantee
10114/02-11-2020, from the date of (PAC) of the Turnkey project (In
GE # case of contract award) and from the date of
TS0792/22-12-2020, delivery for the direct material supply order. The

10. 4 Page 319 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Elektroeramix # guarantee/warranty shall be applicable for ME4


MV2857/2019/28-03 Operating Mechanism for 420kV DS/MES/HES
-2019 from first project and shall cover all the cost of
materials and labor as per warranty/guarantee of
materials and workmanship and subsequently
reduced yearly in case of future project award.
This was confirmed in writing by GE Grid
Solutions, France through their letter #
BHT27032019 dated March 27, 2019.

Hybrid GIS type T155


PQ Letter

Based on S&SD letter # 21-00716-30504401


dated June 14, 2021, the manufacturer is
prequalified for 380kV Hybrid GIS type T155
mono, as confirming to National Grid SA
specification # 32-TMSS-02 Rev. 02, with the
following conditions:

WARRANTY

Ten (10) years extended warranty from the date


of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter No. Nil dated May 25, 2021
shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

10. 4 Page 320 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Switzerland Ltd. 420kV GIS Mfr. Name change from ABB Switzerland Ltd to
SWITZERLAND Type/ Model: ELK-3/420 Hitachi Energy Switzerland AB
(1HC0071250M0070)
Toto Building, Brown Boveri Strasse 5 PQ letter:
8050, Zurich, Switzerland Rating: 420kV, 4000A @40°C, 60Hz, S&SD letter # 13-00748-30504101 dated
63kA(1s)/164kAp November 06, 2013, 420kV GIS type ELK-3/420
Contact Person - MR. Dieter (1HC0071250M0070) @ 4000A, 60Hz.
Fuechsle(Global Qualification and CB: ELK-SP3/420 (double break),
Certification Manager for GIS.), Mr. PQ letter:
Abdulmajeed Alothman Operating Mechanism-HMB8 (Hydraulic Based on S&SD letter #17-5541-1-30504401
Email ID - spring charged) dated July 27, 2017, ABB Switzerland is
[email protected], permitted to use Single Break Circuit Breaker
[email protected] CB Capability: Type SP3-1 (1HC0071250M0080) in the already
om Inductive load switching: Yes Prequalified 380kV GIS Type ELK-3/420 in
Contact Person Email ID - Capacitor bank back to back Switching: addition to the Double Break Circuit Breaker Type
[email protected], Yes SP3 (1HC0071250M0070) as conforming National
[email protected] Grid SA with specification # 32-TMSS-02 Rev.02
om CB: ELK- SP3-1 (1HC0071250M0080) with the following conditions:
Website - www.hitachienergy.com (Single break), Warranty :
•Ten (10) years extended warranty/guarantee in
Rating: 420kV, 5000A @40°C, 60Hz, respect of defects due to design, manufacture,
63kA(3s)/164kAp, installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Operating Mechanism-HMB-4.3 first turnkey project in case of contract award or
(Hydraulic spring) date of delivery in case of direct material supply
order, as confirmed in writing by the
CB Capability: manufacturer through their letter #
Inductive load switching: YES PGHV-160826/GIS-1 dated August 26, 2017.
Capacitor bank back to back switching:
YES HYBRID GIS:
PQ Letter:
Line & Busbar DS: ELK-TK3/420, S&SD letter # 14-03182-01-30504401, dated
Operating Mechanism-ELK-BAC 29-01-2015, Pre-qualified ABB, Switzerland GIS
type ELK-3/420 (1HC0071250M0070) with its
MES: ELK-TK3/420, components are acceptable for Hybrid GIS upto
Operating Mechanism-ELK-BAC current rating @ 3150A, 55°C, 60Hz.

HES: ELK-EB3 420,


Operating Mechanism-ELK-BAE

CT : ELK-CN3

10. 4 Page 321 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Cable compartment: ELK-HK3

420kV HYBRID GIS


Type/ Model: ELK-3/420
(1HC0071250M0070)

Rating: 420kV, 3150A @55°C, 60Hz,


63kA(1s)/164kAp

10. 4 Page 322 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES 420kV GIS 420kV GIS 420kV GIS


CORPORATION (HICO) Type/ Model: HSG 426A 1 Type/ Model: HSG Type/ Model: HSG 426A 1
SOUTH KOREA 426A 1
Ratings: 4000 A@40˚C, 60Hz (indoor), PQ letter:
Plant -Republic of Changwon, Korea Outdoor Exit Bus duct – 4000 A @55˚ Type tests Based on S&SD Letter # MPQ45724310 dated
C, 60Hz, 63kA (1s)/163.4kAp performed at KERI # January 19, 2022, Manufacturer is pre-qualified
Eric Rhie, 450, Gongdeok-Dong, 19 TC101221-R1, for SF6 GAS INSULATED SWITCHGEAR 380 KV
Mapo-Gu, Seoul , Korea CB type: HCHY 426A 1, Single break DT: 02-06/09/2019, as conforming to National Grid SA Specification #
Tel:82-707-6180 without Grading capacitor, Opr. Mech: KERI # 20 32-TMSS-02 rev.02 with the following conditions:
Hydraulic Type HMHY 110C TC100151, DT:
Contact Person - Mr. Jason Kang; Sale 21-08-2019 to Warranty:
Manager & Mr. Young Kim; Sales Capability: Capacitor Bank back- to- 07-02- 2020, KERI # Ten (10) years extended warranty from the date
Manager back switching: YES, Induced current 20 STL00039-R1, of PAC of the first turnkey project (in case of
Contact Person Email ID - switching: YES DT: 10/09 to contract award) or date of first delivery (in case
[email protected] , 17-1-2/2019, KERI # of direct material supply order). as confirmed,
[email protected] DS Type: Busbar DS- HDMO 426A 1b, 20 STL0042, DT: through their letter No. Nil, dated May 30, 2018,
Website - Opr. Mech: HMMO 340, Line DS- HDMO 04-09-2019, KEMA, shall be applicable for the equipment to be
http://www.hyosung.co.kr/eng/index.js 426A 1a, Opr. Mech: HMMO 340 NL # 2075-21, DT: supplied to SEC/National Grid SA.
p?, www.hyosung.com MES Type: HEMO 426A 1, Opr. Mech: 02nd Feb: to 22nd
HMMS 340, Oct: 2021, ISERC #
HES Type: HEMS 426A 1, Opr. Mech: 2019-0099, DT:
HMMS360 (Motor-spring) 13/12 to 17/01-2022, 420kV GIS
KEMA, NL # Type/ Model: HSG 426A
CT: HSG-426 A1_BCT 2351-21, DT: 27th
Sept: to 08th Oct: PQ Letter
Cable sealing end box Type: 2021, KEMA, NL # Based on TS&SD letter
HSG-426A1 CSE 2076-21, DT: 06 #10-F-02299/02-03032301 dated 25/10/2010, it is
Feb: 2021, ISERC # pre-qualified for 420kV GIS with the following
2019-100, DT: conditions:
03-04/12-2019, • Ten (10) years extended warranty for the
420kV GIS Melco # C10-A9N17, proposed 420kV GIS type HSG 426A from the
Type/ Model: HSG 426A DT: 19-29 Aug: date of PAC of the turnkey project in case of
2019, ISERC # contract award or date of delivery in case of
Rating: 420kV, 4000A @55°C, 60Hz, 2019-101, DT: direct material supply order. This was confirmed
63kA(1s)/164kAp 03-04/12-2019 & in writing by Hyosung Corp (Korea) through letter
KERI # 20 #HS-420GIS- 100830-1 dated 30th August 2010.
CB: (Single Break) type HCHY 426A STL00041, DT: CONDITION:
with Hydraulic Mechanism 03/09 to Type Test: Back to back switching tests for the
17-12-/2019 capacitor bank shall be conducted in an
CB Capability: independent test laboratory whenever there is
Inductive load switching: YES project requirement. This was confirmed in
Capacitor bank back to back Switching: writing by Hyosung Corp (Korea) through letter #

10. 4 Page 323 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NO 420kV GIS HS-420GIS-100830-1 dated 30th August 2010.


Type/ Model: HSG
Busbar DS: HDMO426A 426A HYBRID GIS:
Based on S&SD letter #16-02585-02-30504401
Line DS: HDMO 426B CESI-Italy (2009), dated April 10, 2016, pre-qualified Hyosung,
KERI- Korea (2010), Korea 420kV GIS type HSG 426A has
ES: HEMO426A Mitsubishi Electric pre-qualified for Hybrid GIS with following
(MELCO)- Japan, conditions:
H-ES: HEMS 426A Hyosung • Ten (10) years extended warranty from the
corporation, Korea date of PAC of the turnkey project in case of
HYBRID GIS: (2012) contract award and date of delivery in case of
420kV GIS type HSG 426A with its direct material supply order. This is applicable
components, up to current rating from first project and subsequently reduced
4000A, 55 °C, 60Hz yearly in case of future project. This was
confirmed by the manufacturer through letter
#HG-NG-HGIS-160221-420 dated February
21,2016.

10. 4 Page 324 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS AG, 420kV GIS: 420KV New version:


GERMANY PQ Letter:
NEW VERSION: S&SD letter# 14-00569-2-30504401 dated
Plant -Berlin Type/ Model: 8DQ1-6 February 09, 2014 pre-qualified for 420KV GIS
type 8DQ1-6.
Freyeslebenstr. 1 91058 Erlangen, Rating: 420kV, 4000A @40°C, 60Hz,
Germany 63kA(3s)/164kAp WARRANTY:
Ten (10) years extended warranty/guarantee in
Contact Person - Mr. Yaser Salih , CB: CB: 8DQ1- 6-P1 (Single break)/ respect of defects due to design, manufacture,
Juergen Wolff Opr. Mech. Type: Spring type (FA5) installation & workmanship from the date of
Phone - +49 9131 7 25216, +49 9131 7 Provisional Acceptance Certificate (PAC) of the
31625 CB Capability: first turnkey project in case of contract award or
Email ID - Inductive load switching: YES date of delivery in case of direct material supply
[email protected],Juergen.wol Capacitor bank back to back Switching: order, as confirmed in writing by the
[email protected] Yes manufacturer (Siemens AG-Germany) through
LDS: 8DQ1 6 DS / Opr. Mech: Motor their letter # Nil dated May 30, 2012.

BDS: 8DQ1 6 DS / Opr. Mech: Motor 420KV Old Version:

MES: 8DQ1 6 ES / Opr. Mech: Motor 420kV HYBRID GIS:


PQ Letter:
HES: 8DQ1 6 HSES /Opr. Mech: Motor S&SD letter # # 15-05204-01-30504401, dated
spring 28-01-2015, for 420 kV GIS type 8DQ1-6 with its
components are acceptable for Hybrid GIS up to
CT: 8DQ1 6 current rating 3150A, 55 °C, 60Hz.

OLD VERSION: WARRANTY: As per GIS type 8DQ1-6


Type/ Model: 8DQ1

Rating: 420kV

CB: 8DQ1-T2, DOUBLE BREAK,


Hydraulic mechanism
DS Type : 8DQ1

CB Capability:
Inductive load switching: xx
Capacitor bank back to back Switching:
xx

DS: 8QD1

10. 4 Page 325 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

420kV Hybrid GIS:


Type/ Model: 8DQ1-6 with its
components,

Rating: 420kV, 3150A @55°C, 60Hz,


63kA(3s)/164kAp

MITSUBISHI ELECTRIC CORPORATION 420kV GIS ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Type/ Model: 400-GPS
Plant -T&D Systems Center, Amagasaki
City, Japan Rating: 420kV, 4000A @40°C, 60Hz,
63kA(1s)/164kAp
Mitsubishi Electric Corporation, Tdsc,
Marketing Department, 8-1-1 CB:
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan CB Capability:
Inductive load switching: xx
Contact Person - Mr. Yohei Okada Capacitor bank back to back Switching:
Phone - +81-6-6497-8288 xx
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

HITACHI LTD 420kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/ Model: IFT letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
Rating: 420kV, 3150A @40°C, 60Hz
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, CB: Double break
Tokyo, 101-8608, Japan
CB Capability:
Contact Person - Mr. Masaharu Tsumori Inductive load switching:xx
Phone - +81-3-4564-4741 Capacitor bank back to back
Email ID - Switching:xx
[email protected]
Website - http://www.hitachi.com

10. 4 Page 326 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TOSHIBA CORPORATION, T&D 420kV GIS: On HOLD based on VP, Engineering letter #
JAPAN 19-00222-30504401 dated January 24, 2019.
NEW VERSION:
Website - TOSHIBA CORPORATION, T&D JAPAN-
http://www.toshiba.co.jp/index j3.htm Type/ Model: GID ORIGINALLY TMT&D CORP. & DISSOLVED
DURING APRIL 2005.
Rating: 420kV, 3150A @40°C, 60Hz,
63kA(3s)/164kAp PQ Letter:
S&SD letter # 14-05807-2-30504401, dated
CB: GSRK-420CHK (Single break) with September 08, 2014, it is pre-qualified for 420 kV
internal grading capacitor 860pF, GIS type GID.
Operating Mechanism: Hydraulic
GSRK-420CHK
WARRANTY:
CB Capability: Ten (10) years extended warranty/guarantee in
Inductive load switching: YES respect of defects due to design, manufacture,
Capacitor bank back to back Switching: installation & workmanship from the date of
YES Provisional Acceptance Certificate (PAC) of the
Busbar & Line DS: DTM, Operating first turnkey project in case of contract award or
Mechanism DTM (motor) date of delivery in case of direct material supply
order and subsequently reduced yearly in case
MES: EBM, Operating Mechanism EBM of future project award., as confirmed by the
(motor) manufacturer through their letter # TSB/TDS
/AK/130206/2145-R1 dated August 12, 2014
HES: EYP, Operating Mechanism EAP
(motor spring charged)

OLD VERSION:
Type/ Model: GID CB type GSR
400R2B/GSRK, DOUBLE BREAK,
Hydraulic mechanism

Rating: 420kV

10. 4 Page 327 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS Type / Model: YGII


FRANCE
Rating: 420kV
Plant -Grenoble, France
CB: SPD
Siemens S.A.S., 2 rue de la Neva - BP
178 38004 Grenoble, France DS: YGII

Contact Person - Lyons Laurent


Contact Person Email ID -
[email protected]

SIEMENS 420kV GIS


United Kingdom
Type/ Model: YGII (YG2)
Plant -Hebburn
Rating: 420kV, 4000A @40°C, 60Hz,
Tyne & Wear, North Farm Road, Ne31 63kA(1s)/164kAp
1Up Hebburn
CB: SPD
Contact Person - Mr. Russell Elliott
Phone - +44 1914015686 DS: YGII
Email ID - [email protected]

Total = 13

SWITCHGEAR
10. 5
SF6 GAS INSULATED SWITCHGEAR & HYBRID SF6 GAS INSULATED SWITCHGEAR, 550 KV Applicable Standards: 32-TMSS-02
GIS

10. 5 Page 328 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE Grid Solution SAS (GE & Alstom GIS: T155-550kV, 550kV, 63kA Type Tests were PQ letter:
Joint Venture) (1s)/163.8kAp, 3150A, 40ºC, 60Hz performed in Based on S&SD letter # 18-00209/01-30504101
FRANCE CERDA, France, dated July 11, 2018, GE Grid solutions SAS -
Circuit Breaker: T155-CB2, 550kV, KEMA, Netherland France is pre-qualified for 550kV GIS as
Plant -Aix-Les Bains, France 63kA (1s)/ 163.8kAp, 3150A, 40ºC, and CESI, Italy conforming to latest National Grid SA
60Hz with operating mechanism: specification # 32-TMSS-02, with the following
GE Grid Solution SAS (GE & Alstom T155-CI2 (Hydraulic), Capacitor bank conditions:
Joint Venture), 1, Rue Paul Doumer back to back switching: 1000A (C2),
73100 Aix-Les-Bains (France) Inductive current switching: 315A WARRANTY:
Ten (10) years Guarantee/Warranty in respect of
Aix-Les Bains Busbar Disconnector: T155-DS, 550kV, defects due to design, manufacture, installation &
63kA (1s)/ 163.8kAp, 3150A, 40ºC, workmanship from the date of Provisional
Contact Person - Mr. Zinedine RABAH 60Hz, Operating Mechanism: T155-ME Acceptance Certificate (PAC) of the project in
Phone - +33(0) 4 79 88 79 80 + 971 4 case of contract award and from the date of
4299 651 Line side Disconnector: T155-DS, delivery in case of direct material supply order,
550kV, 63kA (1s)/ 163.8kAp, 3150A, as confirmed by the manufacturer vide letter #
40ºC, 60Hz, Operating Mechanism: Nil, dated August 18, 2015
T155-ME

Maintenance Earthing switch:


T155-ES, 550kV, 63kA(1s)/ 163.8kAp,
Operating mechanism: T155-ME

High Speed Earthing Switch: T155-EF,


550kV, 63kA(1s)/ 163.8kAp, Operating
mechanism: T155-ME

Current transformer: T155-CT

Voltage Transformer: T155-VT

10. 5 Page 329 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Switzerland Ltd. 550kV GIS Type test completed Mfr. Name change from ABB Switzerland Ltd to
SWITZERLAND Hitachi Energy Switzerland AB
Type/ Model: ELK-3/550
Toto Building, Brown Boveri Strasse 5 (1HC0071250M0100) 550kV GIS
8050, Zurich, Switzerland
Rating: 550kV, @ 4000A, 40 º C, 60Hz PQ Letter
Contact Person - MR. Dieter S&SD letters 14-00741-30504101dated
Fuechsle(Global Qualification and CB: ELK-SP3/550 (1HC0071250M0100) December 08, 2014 & 14-00043-30504101, dated
Certification Manager for GIS.), Mr. (double break), Operating January 20, 2015, pre-qualified for 550 kV GIS
Abdulmajeed Alothman Mechanism-HMB8 type ELK3/550(1HC0071250M0100).
Email ID - (1HC0071250M0100)
[email protected], WARRANTY:
[email protected] CB Capability: Ten (10) years extended warranty/guarantee in
om Inductive load switching: Yes respect of defects due to design, manufacture,
Contact Person Email ID - Capacitor bank back to back Switching: installation & workmanship from the date of
[email protected], Yes (1000A) Provisional Acceptance Certificate (PAC) of the
[email protected] first turnkey project in case of contract award or
om Busbar DS: ELK- date of delivery in case of direct material supply
Website - www.hitachienergy.com TE3/550(1HC0071250M0100), order and subsequently reduced yearly in case
Operating of future project and shall be applicable for all
Mechanism-DH(1HC0071250M0100) Substations to be supplied to SEC/National Grid
SA as confirmed through ABB, Switzerland Letter
Line DS: # PPHV-550kV dated 02-05-2014.
ELK-TV3/550(1HC0071250M0100),
Operating
Mechanism-DH(1HC0071250M0100)

MES:
ELK-EM3/550(1HC0071250M0100),
Operating
Mechanism-DH(1HC0071250M0100)

HES:
ELK-EB3/550(1HC0071250M0100),
Operating
Mechanism-DB(1HC0071250M0100)

Cable compartment:
ELK-HK3/550(1HC0071250M0100)

10. 5 Page 330 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES 550kV GIS KERI-Korea (2012), 550kV GIS


CORPORATION (HICO) Type/ Model: 550 HSG @ 4000A, 40ºC, KEMA- Netherland PQ Letter:
SOUTH KOREA 60Hz, 63kA(3s)/164kAp (2013), S&SD letters 14-00743-30504101 dated
CB: 550 SPR50 (Single break), FGH-Mannheim December 08, 2014 & 14-00783-30504101, dated
Plant -Republic of Changwon, Korea Operating Mechanism-HOM-110 (2011) 23 December, 2014, pre-qualified for 550 kV GIS.
CB Capability:
Eric Rhie, 450, Gongdeok-Dong, Inductive load switching: Yes CONDITION:
Mapo-Gu, Seoul , Korea Capacitor bank back to back Switching: Type test: 1000A capacitor bank back to back
Tel:82-707-6180 to be performed for 1000A switching current test to be performed in the first
Busbar and Line DS: 550 SDSV, order before delivery of the GIS in the project
Contact Person - Mr. Jason Kang; Sale Operating vide Hyosung, Korea letter # HS-5GIS-1406-1,
Manager & Mr. Young Kim; Sales Mechanism-Motor/DYA0400134 dated 11-06-2014.
Manager MES type 550 SESM, Operating
Contact Person Email ID - Mechanism-Motor DYA0400134 WARRANTY:
[email protected] , HES type 550 HESA, Operating Ten (10) years extended warranty/guarantee in
[email protected] Mechanism-Motor-Spring/DYA0400133 respect of defects due to design, manufacture,
Website - Cable compartment: DYA0208017 installation & workmanship from the date of
http://www.hyosung.co.kr/eng/index.js Provisional Acceptance Certificate (PAC) of the
p?, www.hyosung.com HYBRID GIS: first turnkey project in case of contract award or
550kV GIS type 550HSG with its date of delivery in case of direct material supply
components, up to current rating order and subsequently reduced yearly in case
4000A, 40 °C, 60Hz. of future project and shall be applicable for all
Substations to be supplied to SEC/National Grid
SA as confirmed by M/s. HYOSUNG, Korea
through Letter # Nil, dated Nil.

HYBRID GIS:
Based on S&SD letter #16-02585-02-30504401
dated April 10, 2016, pre-qualified Hyosung,
Korea 550kV GIS type 550 HSG has pre-qualified
for Hybrid GIS with following conditions:
• Ten (10) years extended warranty from the
date of PAC of the turnkey project in case of
contract award and date of delivery in case of
direct material supply order. This is applicable
from first project and subsequently reduced
yearly in case of future project. This was
confirmed by the manufacturer through letter #
HG-NG-HGIS-160221-550 dated February
21,2016

10. 5 Page 331 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS AG, 550kV GIS: Type test are


GERMANY Type/ Model: 8DQ1 completed Except 550kV GIS
Capacitor bank Back PQ Letter:
Plant -Berlin Rating: 550kV, 5000A @40°C, 60Hz, to back switching S&SD letter # 14-00742-30504101, dated
63kA(3s)/164kAp test for 1000A December 08, 2014 the GIS type 8DQ1 is
Freyeslebenstr. 1 91058 Erlangen, approved for 550kV.
Germany CB: 8DQ1-P2 (double break), Opr.
Mech: 3xFA5-Spring charged CONDITION:
Contact Person - Mr. Yaser Salih , Type test for 1000A capacitor bank back to back
Juergen Wolff CB Capability: switching current test to be performed in the first
Phone - +49 9131 7 25216, +49 9131 7 Inductive load switching: YES order before delivery of the GIS in the project as
31625 Capacitor bank back to back Switching: per Siemens letter # E T HP GS/SAR/PQ-GIS
Email ID - to be performed for 1000A 8DQ1-NG 87, dated 06-05-2014.
[email protected],Juergen.wol DS: 8DQ1
[email protected] WARRANTY:
ES: 8DQ1 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
550kV Hybrid GIS: Provisional Acceptance Certificate (PAC) of the
Type/ Model: 8DQ1 first turnkey project in case of contract award or
date of delivery in case of direct material supply
Rating: 550kV, 3150A @55°C, 60Hz, order and subsequently reduced yearly in case
63kA(3s)/164kAp of future project award as confirmed by Siemens
letter # Nil, dated 31-03-2009.

550kV Hybrid GIS


Base on S&SD letter # 15-05204-01-30504401,
dated 28-01-2015, Pre-qualified Siemens,
Germany 550kV GIS type 8DQ1 with its
components are acceptable for Hybrid GIS up to
current rating 3150A, 55 °C, 60Hz.

CONDITION:
As per 550kV GIS type 8DQ1

WARRANTY:
As per 550kV GIS type 8DQ1

Total = 4

10. 5 Page 332 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SWITCHGEAR
10. 6
METAL CLAD GAS INSULATED MEDIUM VOLTAGE SWITCHGEAR (11KV,13.8KV.33KV OR Applicable Standards: 32-TMSS-03
34.5KV)
SIEMENS 33kV GIS PQ Letter:
GERMANY S&SD letter # 15-0186-01-30504401, dated
Type/ Model: 8DA10 January 22, 2015 and TS&SD Letter #
Berlin, Germany 10-02461-02-03032301, dated August 31, 2010,
IC SG EA MF Rating: 36kV, 2500A @40°C, 60Hz, the manufacturer is prequalified for 36kV GAS
Wernerwerkdamm 5, 25kA(3s)/65kAp Insulated Medium Voltage SWGR Type 8DA10.
13629, Berlin, Germany
CB: 3AH49 with vacuum interrupter CONDITION:
Phone - +49 (911) 433 8321 type VSG 40040, rated current up to
Website - 2500A, 40°C, 60Hz WARRANTY:
www.siemens.com/ingenuityforlife Seven (7) years extended warranty/guarantee in
CB: 3AH49 with vacuum interrupter respect of defects due to design, manufacture,
type VS 30040 (40kA), rated current installation & workmanship from the date of
up to 2375A 40°C, 60Hz Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
CB: 3AH49 with vacuum interrupter date of delivery in case of direct material supply
type VS 30040 (40kA), rated current order, as confirmed by Siemens trough letter #
up to 2375A 40°C, 60Hz 8DA10_PQR_R1 dated 24/08/2010

CB Capability:
Capacitor bank back to back Switching:
400A with CB type 3AH49, interrupter
VSG40040

Total = 1

SWITCHGEAR
10. 7
SF6 Non-Extensible Ring Main Unit, 11 KV through 34.5 KV Applicable Standards: 32-TMSS-07

10. 7 Page 333 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ELECTRICAL INDUSTRIES CO. LTD Rating Voltage : 17.5kV


(ABB/AEIL)
Saudi Arabia

Plant -2Nd Industrial Area, Corner No.


61, 224 Street Riyadh

Saudi Arabia

Contact Person - Mr. Naiem Sharqaui


Phone - +966-0504 206 711
Email ID - [email protected]
Website - http://www.abb.com.sa/

AREVA Rating Voltage : 17.5kV


FRANCE

Plant -France

Website - http://www.areva.com/

EPS LTD. (SCHNEIDER GROUPE) Rating Voltage : 17.5kV


Saudi Arabia

Plant -Riyadh, Saudi Arabia

Contact Person - Mr. Rene Datuin


Website -
http://www.schneider-electric.com.sa

FRITZ DRIESHER KG Rating Voltage : 17.5kV


GERMANY

Website -
http://www.driescher.de/home/index.ht
m

GULF REYROLLE LTD Rating Voltage : 17.5kV


Saudi Arabia

Plant -Dammam , Saudi Arabia

10. 7 Page 334 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MERLIN GERIN Rating Voltage : 17.5kV


FRANCE

Website -
http://www.schneider-electric.fr/

SIEMENS AG EVM Rating Voltage : 17.5kV


GERMANY

Plant -Frankfurt , Germany

Website -
http://w1.siemens.com/entry/cc/en/

THE INTERNATIONAL ELECTRICAL Rating Voltage : 17.5kV


PRODUCTS CO.
Saudi Arabia

Plant -Dammam , Saudi Arabia

W. LUCY Rating Voltage : 17.5kV


United Kingdom

Website -
http://www.lucyswitchgear.com/T

Total = 9

SWITCHGEAR
10. 8
LOAD BREAK SWITCHES UPTO 34.5kV Applicable Standards:

10. 8 Page 335 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ELECTRICAL INDUSTRIES CO. LTD


(ABB/AEIL)
Saudi Arabia

Plant -2Nd Industrial Area, Corner No.


61, 224 Street Riyadh

Saudi Arabia

Contact Person - Mr. Naiem Sharqaui


Phone - +966-0504 206 711
Email ID - [email protected]
Website - http://www.abb.com.sa/

KONCAR ELECTRICAL EQUIPMENT


(KONCAR), SPLIT
CROATIA

Plant -Split/Croatia – Hrvatska

Koncar Elektricni Uredaji D.D Prisoje


29A, 21232 Dicmo Hr

Contact Person - Mr.Ljubomir Zubcic


Phone - +38521778512, +385 91 374
2009
Email ID - [email protected]
Website - http://www.koncareu.hr

FRITZ DRIESCHER
GERMANY

HITACHI
JAPAN

EPS LTD. (SCHNEIDER GROUPE)


Saudi Arabia

Plant -Riyadh, Saudi Arabia

Contact Person - Mr. Rene Datuin


Website -
http://www.schneider-electric.com.sa

10. 8 Page 336 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AREVA
FRANCE

SIEMENS
GERMANY

Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany

Phone - +49 (911) 433 8321


Website -
www.siemens.com/ingenuityforlife

Total = 7

SWITCHGEAR
10. 9
Gas Insulated transmission Lines (GIL) for rated voltage 110kV and above Applicable Standards: 32-TMSS-05

10. 9 Page 337 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens High Voltage Switchgear Co., Siemens Energy Limited 420kV GIB/GIL type: 8DQ1 PQ Letter
Ltd. Shanghai Saudi Arabia Based on S&SD letter #22-008282/02-30504401
CHINA Business Gate, Building Rating: 420kV -3150A@55°C, 60Hz, dated 17-05-2023, the manufacturer is
C-1, 63kA (3s)/164kAp prequalified for 420kV GIL type 8DQ1 as
Plant -Shanghai, P.R. China Airport Road, Qurtubah confirming to National Grid SA specification #
District. 32-TMSS-05, with the following conditions:
No. 299 Tian Ning Road, Min Hang P.O. Box 39582, Riyadh
District, Shanghai, P.R. China 11489, TYPE TEST:
Saudi Arabia Fresh Type Tests shall be conducted in an
Shanghai 00966566375966 independent testing laboratory in the presence of
kaisar.langoo@siemens- (03) SEC/National Grid SA representatives and
Contact Person - 1rst Contact: Mr. Xu energy.com one approved third party inspector during first
Feng Yu- Stan 2nd Contact: Mr. Cai Chi SEC/ National Grid SA project/ order and all cost
Xiang- Jason pertaining to tests shall be borne by the
Phone - +86 (21) 24085606 manufacturer. This has been confirmed in writing
Email ID - by the manufacturer through letter #
[email protected] SHVS230406KSAPQ01, dated 06 April, 2023.
Contact Person Email ID - 1st Contact:
[email protected] 2nd
Contact: WARRANTY
[email protected] Ten (10) years extended warranty/guarantee to
Website - www.siemens-energy.com SEC/National Grid SA for the offered 420kV
GIB/GIL type 8DQ1 in respect of the defects due
to design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. #SEC Bulk Tender
Prequalification, dated April 10, 2023.

10. 9 Page 338 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd Model: 550SR/2016 Type tests Previously Hyundai Electric & Energy Systems
SOUTH KOREA Ratings: 420kV / 60Hz /4000A@55˚C successfully Co., Ltd., the name has been changed to HD
/63kA (3s)/163.8kAp completed at KERI– Hyundai Electric Co., Ltd
Plant -Ulsan South Korea;
Model: 550SR/2016-10 Reports KERI #
1000, Bangeojinsunhwan-doro, Rating: 420kV / 60 Hz / 4000A @ 55 °C 20TC100133, dated PQ Letter
Dong-gu, Ulsan, South Korea, / 63kA (1s)/163.8kAp 01 April-2020, KERI
# 20TB100037, Based on S&SD letter # MPQ466720410 dated
Ulsan dated 30 March August 20, 2020, the manufacturer is prequalified
2020 & KERI # for Gas Insulated Transmission Lines (GIL) for
Contact Person - Mr. J.W(Jin) Lee 20TB100037, dated rated voltage 420KV, as confirming to National
Phone - +966-11-293-2026, 30 March 2020. Grid SA specification # 32-TMSS-05, with the
+82-10-4818-0822 following conditions:
Contact Person Email ID - KERI # 22TB100266,
[email protected] DT: 22-09-2022, WARRANTY
Website - KERI # 22TB100265,
http://www.hyundaielectric.com DT: 29-09-2022, Ten (10) years extended warranty from the date
KERI # 21TB10032, of PAC of the first turnkey project (in case of
dt: 01-06-2021, KERI contract award) or date of first delivery (in case
# 21TC100173, dt: of direct material supply order), as confirmed,
20-23/07-2021, KERI through their Letter No. S370-20191111-WL1
# 21TC100172, dt: dated November 11, 2019 shall be applicable for
20-23/07-2021, KERI the equipment to be supplied to SEC/National Grid
# 21TB10031, dt: SA.
14-06-2021

PQ Letter

Based on S&SD letter MPQ1000420410-Class


III-2021 dated March 30, 2023, the manufacturer
is prequalified for Gas Insulated Transmission
Lines (GIL) for rated voltage 420KV, type
550SR/2016-10, as confirming to National Grid SA
specification # 32-TMSS 05, with the following
conditions:

WARRANTY

Ten (10) years extended warranty from the date


of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,

10. 9 Page 339 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

through their Letter No. S370 20210827-WL1


dated August 27, 2021 shall be applicable for the
equipment to be supplied to SEC/National Grid SA

10. 9 Page 340 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. ELK-3/420 (1HC0071250M0070), Type Tests were Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia 420kV, 63kA(1s)/170kAp, 4000A @ 40 performed on July and changed to Hitachi Energy Ltd.
°C and 3150A @ 55°C, 60Hz along with 2017 at PEHLA
Plant -Dammam the following components: Testing Laboratory Previous name was ABB , and changed to ABB
i. VP3 – Parallel Compensator Baden, Switzerland Contracting Co. Ltd based on S&SD letter
PO: 41022, Street 39 cross 144, 2nd ii. VQ3 – Lateral Dismantling Unit and following are #20-01681-30504401 dated October 01, 2020
Industrial City, Dammam 31521, Saudi iii. VQL3 – Lateral Dismantling Unit the type test
Arabi with Axial Compensation reports:
iv. VG3 & VI3 – Connecting Bus PQ Letter:
Dammam v. VL3, VT3 & VX3 – Connecting 17072Ba_HASH651 Based on S&SD letter # 17-07181-2-30504401
Piece 061 dated November 13, 2017, ABB, Dammam - KSA
Contact Person - Abdulmajeed vi. VW3 – Angle Piece 17073Ba_HASH670 is pre-qualified as production factory for GIL &
Alothman ; Mr. Abdullah Hamidaldin ; vii. HD3 (1HC0071250M0070)– SF6 555 ABB s.r.o-PPHV, Czech Republic as feeder
Mr. Jochen Kiefer Insulated Bushing with Porcelain 17074Ba_HASH641 factory as conforming to National Grid SA
Phone - +966 11 2181703; +966 Insulator 659 specification # 32-TMSS-05, with the following
500414555 viii. HK3 (1HC0071250M0070)– Cable 17070Ba_HASH660 conditions:
Email ID - end Termination 877
[email protected] ix. HT3 (1HC0071250M0070)– WARRANTY:
m; Transformer Direct Connection The type test were Ten (10) years extended warranty/guarantee in
[email protected] performed in respect of defects due to design, manufacture,
m; [email protected] June/July 2022 at installation and workmanship from the date of
ELK-3, 420KV (1HC0071250M0070), PEHLA Testing Provisional Acceptance Certificate (PAC) of the
5000A at 40oc laboratory – first turnkey project in case of contract award or
Switzerland, date of first delivery in case of direct material
Ratings: 420kV- 4000A@55˚C, 60Hz & following are the supply order, as confirmed by the manufacturer
5000A@40˚C, 60Hz - /63kA type test reports: vide letter # Nil, dated September 18, 2016.
(3s)/170kAp with following PEHLA # 22062Ba
components PEHLA # 22062Ba-3
VP3 – Parallel Compensator PEHLA # 22062Ba-4 PQ Letter
VQ3 – Lateral Dismantling Unit PEHLA # 22069Ba-1
VQL3 – Lateral Dismantling Unit with PEHLA # 22069Ba-2 Based on S&SD letter # MPQ1000820510 dated
Axial Compensation PEHLA # 22051Ba April 12, 2023, the manufacturer is prequalified
VG3 & VI3 – Connecting Bus PEHLA # 22053Ba, for Hitachi Energy Ltd-Dammam 380kV GIL type
VL3, VT3 & VX3 – Connecting Piece PEHLA # 20090Ba-1 420KV (1HC0071250M0070, as confirming to
VW3 – Angle Piece. PEHLA # 17070Ba, National Grid SA specification # 32-TMSS-05,
HD3 (1HC0071250M0070) – SF6 – to – PEHLA # 17040Ba. with the following conditions:
air termination
HB3 (1HC0071250M0070) – SF6 – to –
air termination WARRANTY
HK3 (1HC0071250M0070) – Cable Ten (10) years extended warranty/guarantee to
sealing end SEC/National Grid SA for the offered 380kV GIL
HT3 (1HC0071250M0070) – SF6-Oil- Type ELK-3, 420KV (1HC0071250M0070) in

10. 9 Page 341 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

termination for TRF/Reactor respect of the defects due to design,


manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # Nil dated October 13, 2021.

GE Grid Solution SAS (GE & Alstom Type: T155 Type Tests were PQ Letter
Joint Venture) Ratings: 420kV / 60Hz /3150A@55˚ successfully Based on S&SD letter # 21-00341-30504401
FRANCE C/63kA (3s)/163.8kAp completed at dated March 25, 2021, GE GRID SOLUTION
CREDA/France SAS/France is prequalified for Gas Insulated
Plant -Aix-Les Bains, France Report # 8158, dt: transmission Lines (GIL/GIB), 420kV, Type: T155,
28-05-2015, 7859-2, as confirming to National Grid SA specification #
GE Grid Solution SAS (GE & Alstom dt: 06-09-2013, 32-TMSS-05, with the following conditions:
Joint Venture), 1, Rue Paul Doumer 6791, dated
73100 Aix-Les-Bains (France) 30-03-2010 & 8858, WARRANTY
dated 30-08-2016, Ten (10) years extended warranty from the date
Aix-Les Bains CESI, Milan Report # of PAC of the first turnkey project (in case of
B5024295-2, dated contract award) or date of first delivery (in case
Contact Person - Mr. Zinedine RABAH 19/20-11-2015 & of direct material supply order), as confirmed,
Phone - +33(0) 4 79 88 79 80 + 971 4 8734-2, dated through their Letter No. SEC_GIB_warranty dated
4299 651 15-01/2016, January 06, 2021 shall be applicable for the
ALSTOM Report # equipment to be supplied to SEC/National Grid SA.
TS0296, dt.
10-03-2014 &
TS0198, dated
01/2012 and
VOLTA/France
Report #
201404522_001,
dated 05-06-02014
respectively.

10. 9 Page 342 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES Type: HSG 426A 1 Type Tests were PQ Letter:
CORPORATION (HICO) successfully Based on S&SD letter # 20-00923-30504401
SOUTH KOREA Ratings: 420kV / 60Hz /4000A@55˚C completed at KERI, dated March 30, 2020, the manufacturer is
/63kA (3s)/163.8kAp South Korea - prequalified for 420 KV Gas Insulated
Plant -Republic of Changwon, Korea Report Transmission Lines (GIL) as confirming to
#19TB101032-R2 & National Grid SA specification # 32-TMSS-05,
Eric Rhie, 450, Gongdeok-Dong, Report with the following conditions:
Mapo-Gu, Seoul , Korea #20TC100023-R1,
Tel:82-707-6180 dated 04.12.2019 WARRANTY:
and 29.01.2020 Ten (10) years extended warranty from the date
Contact Person - Mr. Jason Kang; Sale Respectively. of PAC of the first turnkey project (in case of
Manager & Mr. Young Kim; Sales contract award) or date of first delivery (in case
Manager of direct material supply order), as confirmed,
Contact Person Email ID - through their Letter #HS-SEC-420GIL-200306-01
[email protected] , dated March 06, 2020, shall be applicable for the
[email protected] equipment to be supplied to SEC/National Grid SA.
Website -
http://www.hyosung.co.kr/eng/index.js
p?, www.hyosung.com

SIEMENS AG, 8DQ1- 6 GIB/GIL 420-1ph PEHLA #: 19168 PQ Letter


GERMANY 4000A, @60Hz, 40 ˚C (3150A, @60Hz, Bs-1, Rev.01, dt; 17 Based on S&SD letter # MPQ573620410dated
55 ˚C), 63kA (3s)/170kAp June 2019, 19279 January 06, 2022, the manufacturer is
Plant -Berlin Bs-1, dt; 07 Jan. prequalified for Gas Insulated transmission Lines
2020, 20021Be-1, (GIL) for rated voltage 420kV as confirming to
Freyeslebenstr. 1 91058 Erlangen, dated 31 Jan. 2020, National Grid SA specification # 32-TMSS-05 with
Germany 18073 Bs-1, Rev.01, the following conditions:
dt; 28 June 2018,
Contact Person - Mr. Yaser Salih , 12119Bs-1, Rev.01, WARRANTY
Juergen Wolff dt; 03 July 2012, Ten (10) years extended warranty from the date
Phone - +49 9131 7 25216, +49 9131 7 21050Be, dated 09 of PAC of the first turnkey project (in case of
31625 June, 2021 &19261 contract award) or date of first delivery (in case
Email ID - Bs-1, dt; 25 Oct. of direct material supply order), as confirmed,
[email protected],Juergen.wol 2019 & Siemens # through their Letter No. SE GP T SP BD BD SE -
[email protected] AP94640 dated; GIS dated 18 October, 2021 shall be applicable
05-08-2019 for the equipment to be supplied to SEC/National
Grid SA.

Total = 6

10. 9 Page 343 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SWITCHGEAR
10. 10
CONDENSER BUSBAR SYSTEM 11 kV through 34.5 kV Applicable Standards: 32-TMSS-08

Ritz Instrument Transformers GmbH 36 kV condenser busbar (Indoor): IPH # PQ Letter


GERMANY Designation: SIS 02663-22-0331,
Ratings: 36kV, 2500A @ 40°C, 60Hz, dt:14-07-2022, RST Based on S&SD letter # 23-00004-30504101
Plant -Germany 25kA (1s), IP54, IK10 # P50-22-0244-en, dated January 04, 2023, the manufacturer is
Outer sleeve: Polymeric dt: 29-06-2022, RITZ prequalified for Condenser Busbar as confirming
Mühlberg 1 No. UB 86 to National Grid SA specification # 32-TMSS-08,
97514 Oberaurach-Kirchaich 36 kV condenser busbar (Outdoor): 066/0771-e_R01, with the following conditions:
Designation: SISES IPH #
Contact Person - Nadeem Anjum; Ratings: 36kV, 2500A @ 55°C, 60Hz, 02664-22-0329,
Regional Sales Manager 25kA (1s), IP65, IK10 dt:14-07-2022, RST WARRANTY
Phone - +49 (0)40 511 23-0 Outer sleeve: Stainless steel V4A # P50-22-0242-en,
Email ID - info[at]ritz-international.com dt: 28-06-2022, RST Ten (10) years extended warranty from the date
Contact Person Email ID - 17.5 kV condenser busbar (Indoor): # P50-22-0159, Dt: of PAC of the first turnkey project (in case of
[email protected] Designation: SIS 14-04-2022, RST # contract award) or date of first delivery (in case
Website - www.ritz-international.com Ratings: 17.5kV, 3600A @ 40°C, 60Hz, P50-22-0158, Dt: of direct material supply order), as confirmed,
25kA (1s), IP54, IK10 14-04-2022, RST # through their Letter # Nil dated January 12, 2022,
Outer sleeve: Polymeric. P50-22-0160, Dt: shall be applicable for the equipment to be
14-04-2022, IPH # supplied to SEC/National Grid SA.
17.5 kV condenser busbar (Outdoor): 02666-22-0321,
Designation: SISES dt:12-07-2022, RST
Ratings: 17.5kV, 3600A @ 55°C, 60Hz, # P50-22-0241-en,
25kA (1s), IP65, IK10 dt: 01-07-2022, , IPH
Outer sleeve: Stainless steel V4A # 02666-22-0328,
dt:13-07-2022, RST
# P50-22-0243-en,
dt: 29-06-2022

Total = 1

SWITCHGEAR
10. 11
SF6 GAS FREE INSULATED SWITCHGEAR 110kV to 132kV Applicable Standards: 32-TMSS-02

10. 11 Page 344 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS AG, Siemens Energy Ltd, Designation: 8VN1 (Clean air) PQ Letter
GERMANY Business Gate, Building Ratings: 145kV, 3150A (@ 40 °C, Based on S&SD letter # 22-00513-30504101
C-1, 60Hz, 40kA (3s)/104kAp dated December 29, 2022, the manufacturer is
Plant -Berlin Airport Road, Qurtubah prequalified for SF6 GAS FREE INSULATED
District. CB: 8VN1, Opr. Mech: FA2 (Spring SWITCHGEAR 110kV to 132kV Type 8VN1 as
Freyeslebenstr. 1 91058 Erlangen, P.O. Box 39582, Riyadh Charged), M2 confirming to National Grid SA specification
Germany 11489, Capacitor switching capability: NO, #32-TMSS-02, with the following conditions:
Reactive current switching capability:
Contact Person - Mr. Yaser Salih , Thamer Alghafees NO CONDITION:
Juergen Wolff +966542222596 Fresh Type Tests shall be conducted in an
Phone - +49 9131 7 25216, +49 9131 7 Thamer.alghafees@siem BDS & LDS: 8VN1-3PS, Opr. Mech: independent testing laboratory in the presence of
31625 ens-energy.com motor operated, M2 (03) SEC/National Grid SA representatives and
Email ID - MES: 8VN1-ES. Opr. Mech: motor one approved third party inspector during first
[email protected],Juergen.wol operated M1 (2000 Opr.) SEC/ National Grid SA project/ order and all cost
[email protected] HES: 8VN1-HSES, Spring charged, M1 pertaining to tests shall be borne by the
(2000 Opr.) manufacturer. This has been confirmed in writing
Cable sealing end box: 8VN1 Z1 by the manufacturer through letter #
GIS to oil TRF termination (GIB): 8DN8 SEC-PQ-8VN1-001, dated 27 December, 2022.

WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter # SE GP T SP PRO DE OM FIN
dated September 23, 2022, shall be applicable for
the equipment to be supplied to SEC/National Grid
SA.

Total = 1

SWITCHGEAR
10. 13
SF6 Gas Free transmission Lines (GIL) for rated voltage 110kV and above Applicable Standards: 32-TMSS-05

10. 13 Page 345 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. EconiQ ELK-3, 420 kV (1 PEHLA # 22037Ba, PQ Letter


Saudi Arabia HC0071250M0570) dt: 27-04-2022, Based on S&SD letter # 23-02047-01-30504401
SATS # 15-A18, dt: dated October 18, 2023, Hitachi Energy SA,
Plant -Dammam Ratings: 420kV, 63kA(3s)/170kAp, 15-04-2011, PEHLA Dammam – KSA is pre-qualified as production
5000A @ 40°C and 4000A @ 55°C, # 21086Ba, dt: factory & Hitachi Energy s.r.o, Czech Republic as
PO: 41022, Street 39 cross 144, 2nd 60Hz along with following components; 21-07-2021, PEHLA feeder factory for SF6 Gas free Gas Insulated
Industrial City, Dammam 31521, Saudi # 17070Ba, dt: transmission Lines (GIL) for rated voltage 420kV
Arabi VP3, VG3, VQ3, VR, VT3, ZX3, VX3, 28-07-2017, PEHLA as confirming to National Grid SA specification #
VL3 – Connecting pieces # 21118Ba, dt: 32-TMSS-05 with following conditions:
Dammam ZX3 – End cover 10-12-2021, PEHLA
VQL3 – Lateral Dismantling Unit with # 21120Ba-1, dt: TYPE TEST CONDITION:
Contact Person - Abdulmajeed Axial Compensation 02-12-2021, PEHLA Hitachi Energy SA will perform Dielectric and
Alothman ; Mr. Abdullah Hamidaldin ; VW3 – Angle Piece # 21120Ba-1, dt: Temperature rise test for the product from KSA in
Mr. Jochen Kiefer SF6 Air bushing: HD3 02-12-2021, PEHLA an accredited test lab in the presence of three
Phone - +966 11 2181703; +966 (1HC0071250M0570)- Porcelain # 22045Ba-1, dt: (03) SEC/National Grid SA engineers and one
500414555 type-SF6 & HB3 (1HC0071250M0570) 10-06-2022 (01) SEC/National Grid SA approved 3rd party
Email ID - – composite - SF6 Independent Inspection Agency (IIA) inspector
[email protected] HK3 (1HC0071250M0570) – Cable during first project awarded. All cost of which
m; sealing end shall be borne by the manufacturer. This was
[email protected] HT3 (1HC0071250M0570) – SF6-Oil- confirmed in writing by the manufacturer through
m; [email protected] termination for TRF/Reactor their letter Ref. # HV-AO/18-01-23/002 dated 18
January.2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for SF6 Gas free Gas
Insulated transmission Lines (GIL) for rated
voltage 420kV in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # HV-AO/10-10-22/001
dated 10.October.2022.

Total = 1

LIGHTNING & SURGE PROTECTION DEVICES


11. 1
SURGE ARRESTERS, (11 KV THROUGH 380 KV) Applicable Standards: 35-TMSS-01

11. 1 Page 346 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AREVA
FRANCE

Plant -France

Website - http://www.areva.com/

JAPAN AE POWER SYSTEMS CORP.


JAPAN

Website - http://www.jaeps.com/eng/

SIEMENS ,GERMANY
GERMANY

Plant -Berlin Germany

Germany

Website -
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

11. 1 Page 347 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Switzerland Ltd Hitachi Energy Type/Model: Change name from ABB HV TECHNOLOGIES
SWITZERLAND Hitachi Energy Ltd. SWITZERLAND to Hitachi Energy Switzerland
Riyadh, Saudi Arabia Rating: 420kV
Plant -Jurastrasse 45,Ch-5430 Phone: +966 11 2181703
Wettingen, Switzerlandaddress: Doser, Mobile: +966 500414555 Type/Model:
Jurastrasse 45, Ch-5430 Wettingen, abdulmajeed.alothman@
Switzerland hitachienergy.com Type/Model:

Esentepe Mahallesi, Milangaz Cad No. Rating: 245kV


52 Kartal 34870, Istanbul -Turkey
Type/Model:
Contact Person - Mr. Yasser Mahfouz,
Mr. Abdulmajeed Alothman () Rating: 145kV
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

TE ENERGY / TYCO ELECTRONIC MDAE4-120 Class 4 up to 132 kV Type tested in CESI PQ Lettter
United Kingdom Lab Italy in the Based on S&SD letter # 15-09503-01-030504401,
presence of TE Witham Uk is prequalified for Surge Arrester
Plant -Witham Uk (Plant) SEC/National Grid type MDAE4-120 Class 4 up to 132 kV.
SA engineers & SGS
Bowthorpe Emp Stevenson Road Inspector on 7th to WARRANTY:
Brighton East Sussex Bn2 0Df 19th April 20414 Ten (10) years Guarantee / warranty for the in
.Seal Leak Test on respect of defects due to design, manufacture,
Contact Person - Mr. Oday M. Hindi conducted in TYCO installation & workmanship from the date of
Transmission Support Manager,Mr. Electronics test Provisional Acceptance Certificate (PAC) of the
Graeme Currie, Product Manager Laboratory (Whitam, first turnkey project in case of contract award or
Phone - +44-0-1273-692591 UK) in the presence date of delivery in case of direct material supply
Email ID - [email protected], of SGS Inspector order, as confirmed by the manufacturer thru
[email protected] and CESI letter #nil, dt: Sep 14, 2011.
representative on
15th to 16th Sep
2015.
Report, General
report No.
TE-MDAE4-120

11. 1 Page 348 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELPRO INTL. LTD Rating: up to 132kV only PQ Letter:


INDIA
CONDITION:
Plant -India Complete Type, Routine /Acceptance tests for
first order
Website - http://www.elpro.co.in
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

HUBBELL POWER SYSTEMS, INC. Previously OHIO BRASS [The name has been
United States changed based on S&SD/P&SFD letter#
14-07802-30504401 dated October 22, 2014 and
Plant -Columbia , United States based on Hubbell Power System Grid Letter # Nil
dated October 06, 2014]

TRIDELTA MEIDENSHA GMBH Previously " TRIDELTA ", the name has been
GERMANY changed to TRIDELTA Meidensha GmbH -
Germany, based on TRIDELTA Meidensha GmbH
Website - http://www.tridelta.de/ Letter #Nil dated August 10, 2016.

HITACHI LTD Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

11. 1 Page 349 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MITSUBISHI ELECTRIC CORPORATION ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Plant -T&D Systems Center, Amagasaki


City, Japan

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

EATON Previously “COOPER (MCGRAW-ED)”, the name


United States has been changed to “Eaton” based on
S&SD/P&SFD letter # 15-04107-30504401 dated
Plant -Olean, NY May 19, 2015 and COOPER (MCGRAW-ED) letter
# 01110502015 dated May 11, 2015.
1648 Dugan Road
Olean, NY 14760

Contact Person - John Voukelatos


Phone - +1 877-277-4636; +30 210 964
6332
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website -
https://www.eaton.com/us/en-us/catal
og/medium-voltage-power-distribution-
control-systems/station-class-arrester
s.html

11. 1 Page 350 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

Total = 14

CIRCUIT BREAKERS
12. 1
CIRCUIT BREAKER, SF6, DEAD TANK, 69 KV Applicable Standards: 37-TMSS-01

Hitachi Energy USA Inc. Hitachi Energy Mfr. Name change from ABB T&D to Hitachi
United States Hitachi Energy Ltd. Energy USA Inc
Riyadh, Saudi Arabia
Plant -United Stated Phone: +966 11 2181703
Mobile: +966 500414555
100 Distribution Circle, Moint Pleasant abdulmajeed.alothman@
PA 15666 USA hitachienergy.com

Contact Person - Mr. Abdulmajeed


Alothman
Email ID -
[email protected],
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

12. 1 Page 351 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Hitachi T&D Solutions Previously GE-Hitachi HVB


United States

Plant -Georgia , United States

Georgia

Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m

MITSUBISHI ELECTRIC CORPORATION ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Plant -T&D Systems Center, Amagasaki


City, Japan

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

ALSTOM Grid LLC Previously AREVA [The name has been changed
United States to ALSTOM Grid LLC].

Plant -Charleroi , United States

Website - http://www.areva.com/

12. 1 Page 352 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HITACHI LTD Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

SIEMENS, GERMANY Type / Model: 3AP1-DT PQ Letter:


GERMANY S&SD Letter 12-2202-01-30504401 dated July
24, 2012, it is pre-qualified for Dead Tank Circuit
Plant -Berlin Germany Rating: 72.5 kV Breaker type 3AP1 DT 72.5KV & 145KV

Nonnendammallee 104 13629 Berlin, CB Capability: WARRANTY:


Germany Inductive load switching: No Ten (10) years extended warranty/guarantee in
Capacitor bank back to back Switching: respect of defects due to design, manufacture,
Contact Person - Mr. Andre NO installation & workmanship from the date of
HolldorfPhone,Jens Klaua Provisional Acceptance Certificate (PAC) of the
Phone - +49 (30) 386-57542, 49 174 confirmed by Siemens through their first turnkey project in case of contract award or
1533118 letter# E T HP CB B SL/MTH dated April date of delivery in case of direct material supply
Email ID - [email protected] 27, 2012. order, as confirmed by the manufacturer thru
, [email protected] letter #E T HP CB BSL/MTH dt: Dec 18, 2012.
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

Total = 8

12. 1 Page 353 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CIRCUIT BREAKERS
12. 2
CIRCUIT BREAKER, SF6, DEAD TANK, ,110 - 132 KV Applicable Standards: 37-TMSS-01

Hitachi Energy USA Inc. Hitachi Energy Mfr. Name change from ABB T&D to Hitachi
United States Hitachi Energy Ltd. Energy USA Inc
Riyadh, Saudi Arabia
Plant -United Stated Phone: +966 11 2181703
Mobile: +966 500414555
100 Distribution Circle, Moint Pleasant abdulmajeed.alothman@
PA 15666 USA hitachienergy.com

Contact Person - Mr. Abdulmajeed


Alothman
Email ID -
[email protected],
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

SIEMENS Type / Model: 3AP1 DT 72.5KV &


United States 145KV

Website - Rating: 145kV


http://www.usa.siemens.com/entry/en/
CB Capability:
Inductive load switching: No
Capacitor bank back to back Switching:
NO
confirmed by Siemens through their
letter# E T HP CB BSL/MTH dated April
27, 2012

12. 2 Page 354 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM Grid LLC Type / Model: DT1-145FK Previously AREVA [The name has been changed
United States to ALSTOM Grid LLC].
Rating: 132kV, 2000A, 40kA
Charleroi, United States PQ Letter:
TS&SD letter # 10-02708-02-03032301 dated
25/10/2010, it is pre-qualified for 145kV Dead
Tank Circuit Breaker type DT1-145FK, 40KA,
2000A.

CONDITION:

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter as confirmed by the manufacturer thru
letter #nil, dt: 6th Mar, 2009.

Hitachi T&D Solutions Previously GE-Hitachi HVB


United States

Plant -Georgia , United States

Georgia

Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m

12. 2 Page 355 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MITSUBISHI ELECTRIC CORPORATION Type / Model: 120-SFMT-40E ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 145kV, 40kA 2000A
Plant -T&D Systems Center, Amagasaki
City, Japan

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

HITACHI LTD Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

12. 2 Page 356 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB
SWITZERLAND

Contact Person - Mr. Klaus Lohse


Phone - +41 58 588 33 50
Email ID - [email protected]
Website - http://www.abb.ch/

SIEMENS, GERMANY Type / Model: 3AP1 DT 145KV PQ Letter:


GERMANY S&SD Letter 12-2202-01-30504401 dated July
Rating: 145kV, 24, 2012, pre-qualified for Dead Tank Circuit
Plant -Berlin Germany Breaker type 3AP1 DT 72.5KV & 145KV.
CB Capability:
Nonnendammallee 104 13629 Berlin, Inductive load switching: No WARRANTY:
Germany Capacitor bank back to back Switching: Ten (10) years extended warranty/guarantee in
NO respect of defects due to design, manufacture,
Contact Person - Mr. Andre confirmed by Siemens through their installation & workmanship from the date of
HolldorfPhone,Jens Klaua letter# E T HP CB BSL/MTH dated April Provisional Acceptance Certificate (PAC) of the
Phone - +49 (30) 386-57542, 49 174 27, 2012 first turnkey project in case of contract award or
1533118 date of delivery in case of direct material supply
Email ID - [email protected] order, as confirmed by the manufacturer thru
, [email protected] letter #E T HP CB BSL/MTH dt: Dec 18, 2012.
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

Total = 10

CIRCUIT BREAKERS
12. 3
CIRCUIT BREAKER, SF6, DEAD TANK, 230 KV Applicable Standards: 37-TMSS-01

12. 3 Page 357 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy USA Inc. Hitachi Energy Mfr. Name change from ABB T&D to Hitachi
United States Hitachi Energy Ltd. Energy USA Inc
Riyadh, Saudi Arabia
Plant -United Stated Phone: +966 11 2181703
Mobile: +966 500414555
100 Distribution Circle, Moint Pleasant abdulmajeed.alothman@
PA 15666 USA hitachienergy.com

Contact Person - Mr. Abdulmajeed


Alothman
Email ID -
[email protected],
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Hitachi T&D Solutions Previously GE-Hitachi HVB


United States

Plant -Georgia , United States

Georgia

Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m

12. 3 Page 358 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MITSUBISHI ELECTRIC CORPORATION Type / Model: 200-SFMT-40E ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 245 kV, 40kA, 3150 A
Plant -T&D Systems Center, Amagasaki
City, Japan

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

ALSTOM Grid LLC Type / Model: DT1-245 F3 Previously AREVA [The name has been changed
United States to ALSTOM Grid LLC].
Rating: 230kV, 2500A, 60Hz
Plant -Charleroi , United States PQ Letter:
Type DT1-245 F3
Website - http://www.areva.com/
CONDITION:
Di-electric test, riv test, continuous current
temperature rise test @ 2500 A, 60Hz is to be
carried out in the first batch in the presence of 3
SEC engineers and 1 IIA inspector.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

12. 3 Page 359 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HITACHI LTD Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

Total = 7

CIRCUIT BREAKERS
12. 4
CIRCUIT BREAKER, SF6, LIVE TANK, 69 KV Applicable Standards: 37-TMSS-02

12. 4 Page 360 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden

Contact Person - Mr. Anders L


katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

ABB
SWITZERLAND

Contact Person - Mr. Klaus Lohse


Phone - +41 58 588 33 50
Email ID - [email protected]
Website - http://www.abb.ch/

SIEMENS, GERMANY
GERMANY

Plant -Berlin Germany

Nonnendammallee 104 13629 Berlin,


Germany

Contact Person - Mr. Andre


HolldorfPhone,Jens Klaua
Phone - +49 (30) 386-57542, 49 174
1533118
Email ID - [email protected]
, [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

12. 4 Page 361 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AREVA
SWITZERLAND

Plant -Oberentfelden , Switzerland

Website - http://www.areva.com/

AREVA
FRANCE

Plant -Villeur Banne, France

Website - http://www.areva.com/

Total = 5

CIRCUIT BREAKERS
12. 5
CIRCUIT BREAKER, SF6, LIVE TANK, 110 - 132 KV Applicable Standards: 37-TMSS-02

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

12. 5 Page 362 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS, GERMANY
GERMANY

Plant -Berlin Germany

Nonnendammallee 104 13629 Berlin,


Germany

Contact Person - Mr. Andre


HolldorfPhone,Jens Klaua
Phone - +49 (30) 386-57542, 49 174
1533118
Email ID - [email protected]
, [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

AREVA
FRANCE

Plant -Villeur Banne, France

Website - http://www.areva.com/

AREVA
GERMANY

Website - http://www.areva.com/

Total = 4

CIRCUIT BREAKERS
12. 6
CIRCUIT BREAKER, SF6, LIVE TANK, 230 KV Applicable Standards: 37-TMSS-02

12. 6 Page 363 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

SIEMENS, GERMANY
GERMANY

Plant -Berlin Germany

Nonnendammallee 104 13629 Berlin,


Germany

Contact Person - Mr. Andre


HolldorfPhone,Jens Klaua
Phone - +49 (30) 386-57542, 49 174
1533118
Email ID - [email protected]
, [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

AREVA
FRANCE

Plant -Villeur Banne, France

Website - http://www.areva.com/

12. 6 Page 364 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 3

POWER LINE CARRIER, SUPERVISORY CONTROL


13. 1
LINE TRAP Applicable Standards: 38-TMSS-01

HAEFELY-TRENCH ELECTRIC
CANADA

Website -
http://www.electricityforum.com/produ
cts/htg.htm

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

Total = 2

POWER LINE CARRIER, SUPERVISORY CONTROL


13. 2
LINE TUNER Applicable Standards: 38-TMSS-02

ABB HV TECHNOLOGIES
Swaziland

Plant -Jurastrasse 45,Ch-5430


Wettingen, Switzerlandaddress: Doser,
Jurastrasse 45, Ch-5430 Wettingen,
Switzerland

Esentepe Mahallesi, Milangaz Cad No.


52 Kartal 34870, Istanbul -Turkey

Contact Person - Mr. Bernhard


Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - http://www.abb.ch/

13. 2 Page 365 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 1

POWER LINE CARRIER, SUPERVISORY CONTROL


13. 3
REMOTE TERMINAL UNIT (RTU) Applicable Standards: 38-TMSS-03

ALSTOM GRID AUTOMATION UNIT PQ Lettter


COGELEX Based on S&SD letter # 15-00240-02-30504401
Saudi Arabia dated March 03, 2015, the manufacturer is
prequalified for Integration (assembly) & Testing
Plant -Jeddah , Saudi Arabia of Communication & SCADA equipment as
conforming to National Grid SA specification #
PO Box 8535 Jeddah 21492 Saudi 48-TMSS-06, Rev.0 with the following conditions:
Arabia
CONDITION
Contact Person - Mr.Firas Salman ,Unit Only for integration (assembly) & testing of
Commercial Director –NMs communication & SCADA equipment from original
Phone - +966-02-6518610 ,6513476 equipment manufacturer (OEM) type tested and
Contact Person Email ID - approved by SEC/National Grid SA.
[email protected]
Website - http://www.Alstom.com WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design,
manufacture,installation & workmanship from the
date of Provisional Acceptance Certificate (PAC)
of the first turnkey project in case of contract
award or date of delivery in case of direct
material supply order, as confirmed by the
manufacturer thru letter #RN-2013-12-3 NMS/1
dated December 03, 2013.

13. 3 Page 366 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.

Plant -2Nd Industrial Area,Riyadh, Previous name was ABB Electrical Industries
Company Ltd, and changed to ABB Contracting
Po Box 325841 Riyadh,11371 KSA Co. Ltd based on S&SD letter
#20-01681-30504401 dated October 01, 2020
Contact Person - Mr. Essam
Bashraheel & Mr. Ahmed Abubasha
Phone - Tel:+966-011-476-2644 PQ Letter
Fax:+966-011-476-9622 Based on S&SD Letter No. 16-06734-30504401
Contact Person Email ID - dated 31 Aug 2016. It is Prequalified for
[email protected] Integration (Assembly) & Testing of
& SCADA/RTU560 Equipment from Original
[email protected] Equipment Manufacturer (OEM) type tested and
approved by SEC/National Grid SA Specification
38-TMSS-03 Rev.01 with the following Conditions

*.Only for Integration (Assembly) & Testing of


SCADA/RTU560 Equipment from Original
Equipment Manufacturer (OEM) type tested and
approved by SEC/National Grid SA.

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # PSN/SCA/08022016/ 2016, dt: 06/11/2016.

13. 3 Page 367 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EFACEC SISTEMAS DE ELCTRONICA, Bandariyah International Type/Model - CLP500 Institue Electro PQ Lettter
S.A Co. Ltd Tecnico Portugues Based on TS&SD letter# 09-01819-03032301
PORTUGAL 3rd Fllor, Building 3 Portugal, Labecm dated 23rd June 2009, it is prequalified for for
Mutlaq Office comple Al Laboratoriao De. RTU type CLP500 as confirming to SEC
Plant -Maia/Portugal Khobar KSA compatibbilidate specification # 38-TMSS-03, rev.0 with the
Phone - 0553712308 electromagnet ica. following condition:
Rua Eng Frederico Ulrich, Ap 3078 Email - Test Date - jan 2010,
,4471-907 Maia Portugal Maia , Portugal [email protected] July 2010 WARRANTY
Test Report No. - Ten (10) years extended warranty/guarantee in
Contact Person - Mr. Ricardo Cunha, E-2009-1004.02 , respect of defects due to design, manufacture,
Mr. André Cruz 09-12-119-022a installation & workmanship from the date of
Phone - +351 932025959; +351 Provisional Acceptance Certificate (PAC) of the
229402000; +351 939333313 first turnkey project in case of contract award or
Email ID - [email protected]; date of delivery in case of direct material supply
[email protected]; [email protected]. order.
Website -
http://www.efacec.pt/en/automation/

FOXBORO
AUSTRALIA

Website - http://www.foxboro.com/

GE HARRIS HARRIS D20


CANADA

Website - http://www.harris.com/view
pressrelease.aspact=lookup&pr id=318

HARRIS CORPORATION HARRIS MICROPLEX 5000


United States

Melbourne, Florida , United States

Website - http://www.harris.com/

13. 3 Page 368 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JAL INTERNATIONAL ASSEMBLING ONLY


Saudi Arabia

Khobar , Saudi Arabia

Contact Person - Mr. Muhammad Sajjad


Manzoor. Sales Manager (A)
Contact Person Email ID -
[email protected]
Website -
http://www.jalinternational.com.sa/V2/j
al/

SAT
AUSTRIA

SIEMENS Siemens Ltd IC SG EA Type/Model - RTU's


GERMANY Pro Siemens - DE 712
Contact Person: Mr.
Plant -Berlin Germany Ahmad Ainousah, 10:14
AMJeddah 21412
Siemens Ltd Ic Sg Ea Mf Werner Baladiyah Street
Werkdamm 5 13629 Berlin Germany Phone -
+966-12-6618869
Phone - +49(30)386-26688 Email -
Email ID - [email protected] ahmad.ainousah@sieme
Website - ns.com
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx

SIEMENS (LANDYS) - TELEGYR TELEGYR 5700


United States

San Jose, Ca , United States

Website -
http://w1.siemens.com/entry/cc/en/

VA TECH
AUSTRIA

13. 3 Page 369 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LSIS , PQ Lettter
SOUTH KOREA Based on TS&SD letter# 08-00492/1--03032301
dated 24th March, 2008, it is prequalified for for
Ls Tower, 127, Ls-Ro, Dongan-Gu, RTU, SOE and associated transducers with the
Anyang-Si, Gyeonggi-Do, following condition

Contact Person - Mr. Je-woo, Lee WARRANTY


Assistant Manager Seven (7) Years extended warranty/guarantee in
Phone - +82-2-2034-4541 respect of defects due to design, manufacture,
Email ID - [email protected] installation & workmanship from the date of
Website - http://www.lsis.com Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.OS755-013, dt: 15th feb, 2008..

AREVA
FRANCE

Plant -France

Website - http://www.areva.com/

ABB AG RTU-560, SPIDER 200,232 & 233


GERMANY

Mannheim, Germany , Brown Boveri


Street 30, 63457 Hannau, Germany

Contact Person - Mr. Josef Hanson


Email ID - [email protected]
Website - http://
http://www.abb.de/cawp/deabb200/ea
b4f33d72c264bec1256fb90037eeaa.as
px

Total = 14

POWER LINE CARRIER, SUPERVISORY CONTROL


13. 4
SEQUENCE OF EVENTS RECORDER SYSTEM Applicable Standards: 38-TMSS-04

13. 4 Page 370 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID AUTOMATION UNIT PQ Lettter


COGELEX Based on S&SD letter # 15-00240-02-30504401
Saudi Arabia dated March 03, 2015, the manufacturer is
prequalified for Integration (assembly) & Testing
Plant -Jeddah , Saudi Arabia of Communication & SCADA equipment as
conforming to National Grid SA specification #
PO Box 8535 Jeddah 21492 Saudi 48-TMSS-06, Rev.0 with the following conditions:
Arabia
CONDITION
Contact Person - Mr.Firas Salman ,Unit Only for integration (assembly) & testing of
Commercial Director –NMs communication & SCADA equipment from original
Phone - +966-02-6518610 ,6513476 equipment manufacturer (OEM) type tested and
Contact Person Email ID - approved by SEC/National Grid SA.
[email protected]
Website - http://www.Alstom.com WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design,
manufacture,installation & workmanship from the
date of Provisional Acceptance Certificate (PAC)
of the first turnkey project in case of contract
award or date of delivery in case of direct
material supply order, as confirmed by the
manufacturer thru letter #RN-2013-12-3 NMS/1
dated December 03, 2013.

13. 4 Page 371 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.

Plant -2Nd Industrial Area,Riyadh, Previous name was ABB Electrical Industries
Company Ltd, and changed to ABB Contracting
Po Box 325841 Riyadh,11371 KSA Co. Ltd based on S&SD letter
#20-01681-30504401 dated October 01, 2020
Contact Person - Mr. Essam
Bashraheel & Mr. Ahmed Abubasha
Phone - Tel:+966-011-476-2644 PQ Letter
Fax:+966-011-476-9622 Based on S&SD Letter No.
Contact Person Email ID - 16-06734-30504401dated 31 Aug 2016. It is
[email protected] Prequalified for Integration (Assembly) & Testing
& of SCADA/RTU560 Equipment from Original
[email protected] Equipment Manufacturer (OEM) type tested and
approved by SEC/National Grid SA Specification
38-TMSS-03 Rev.01 with the following
Conditions

*.Only for Integration (Assembly) & Testing of


SCADA/RTU560 Equipment from Original
Equipment Manufacturer (OEM) type tested and
approved by SEC/National Grid SA.

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # PSN/SCA/08022016/ 2016, dt: 06/11/2016.

GE HARRIS HARRIS D20


CANADA

Website - http://www.harris.com/view
pressrelease.aspact=lookup&pr id=318

13. 4 Page 372 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JAL INTERNATIONAL SOE RECORDING SYSTEM AND INTERFACE &


Saudi Arabia CONTROL CABINET / MARSHALING PANELS

Khobar , Saudi Arabia

Contact Person - Mr. Muhammad Sajjad


Manzoor. Sales Manager (A)
Contact Person Email ID -
[email protected]
Website -
http://www.jalinternational.com.sa/V2/j
al/

LSIS , WARRANTY
SOUTH KOREA Seven (7) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Ls Tower, 127, Ls-Ro, Dongan-Gu, installation & workmanship from the date of
Anyang-Si, Gyeonggi-Do, Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Contact Person - Mr. Je-woo, Lee date of delivery in case of direct material supply
Assistant Manager order.
Phone - +82-2-2034-4541
Email ID - [email protected]
Website - http://www.lsis.com

ABB AG RTU 560


GERMANY

Mannheim, Germany , Brown Boveri


Street 30, 63457 Hannau, Germany

Contact Person - Mr. Josef Hanson


Email ID - [email protected]
Website - http://
http://www.abb.de/cawp/deabb200/ea
b4f33d72c264bec1256fb90037eeaa.as
px

13. 4 Page 373 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RONAN ENGINEERING X500E/1000


United States

Los Angeles, Ca , United States

Website - http://www.ronan.com/

Total = 7

POWER LINE CARRIER, SUPERVISORY CONTROL


13. 5
ANNUNCIATOR SYSTEMS Applicable Standards: 38-TMSS-05

AMETEK POWER INSTRUMENTS


United States

United States

Website -
http://www.ametekpower.com/

NEXANS
SWITZERLAND

PAN ALARM
United States

RONAN ENGINEERING
United Kingdom

Website - http://www.ronan.com/

13. 5 Page 374 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Eaton Electric Ltd Previously RTK ENGINEERING Ltd, United


United Kingdom Kingdom, name has been changed based on their
letter # Nill. dated September 08, 2018.
Great Marlings, Butterfield Luton,
Bedfordshire LU2 8DL

Contact Person - Peter Cartmell


Phone - +44 1582 723633
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.rtkinstruments.com

STEINER
JAPAN

Website -
http://www.steiner-binoculars.com/ind
ex.html

ABB SUBSTATION AUTOMATION OY


FINLAND

Website - http://www.abb.fi/

Sumitomo Electric Industries Based on S&SD letter#20-02008-30504401 dated


JAPAN 13 December 2020, the name was changed from
J-Power Systems to Sumitomo Electric Industries
3-13-16 Mita- Minato-Ku, Tokyo
108-0073 , Japan

Contact Person - Shiro Nomura & Mr.


Amjad Abdelaziz
Contact Person Email ID -
[email protected] &
[email protected]
Website -
http://www.jpowers.co.jp/english/inde
x.html

13. 5 Page 375 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LS PREVIOUSLY LG
SOUTH KOREA

Website - http://www.lscable.com/

SIEMENS
GERMANY

Plant -Berlin. Germany

Freyeslebenstr 1 91058 Erlangen

Contact Person - Mr. Yaser Salih


Phone - +49-9131725216
Email ID - [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

FUJIKURA VISCAS CORP


JAPAN

Website - http://www.ffcpg.com.my/

PIRELLI
GERMANY

Berlin , Germany

Website - http://
http://www.pirelli.com/splash/index.htm
l

Total = 12

POWER LINE CARRIER, SUPERVISORY CONTROL


13. 6
DYNAMIC SYSTEM MONITORING EQUIPMENT Applicable Standards: 38-TMSS-06

13. 6 Page 376 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AMETEK (ROCHESTER) SAUDI ARABIAN Multifunction Recorders TR-2200, Type Tests PQ Letter
United States INDUSTRIAL & TRADING 57-120V RMS, 1A or 5A RMS performed at RETLIF Based on S&SD letter#18-04456-030504401.
CO. LTD. (SAIT) Test Lab, New York, dated January 06, 2019, the manufacturer is
Plant -ROCHESTER, NY 00-966-13-8344122 USA , February prequalified for Dynamic System Monitoring
[email protected] , 28-March 2, 2018 Equipments as confirming to SEC specification #
255 North Union Street [email protected] with Retest on 38-TMSS-06, Rev.0, with the following
Rochester, N.Y. 14605 Failed Bump Test on conditions:
United States March 5-8, 2018

ROCHESTER, NY WARRANTY
Ten (10) years extended warranty in respect of
Contact Person - Sal Cardella- Product the defects due to design, manufacturing,
Marketing Manager, Steve Bleier - installation and workmanship from the date of the
Director of Marketing and Business Provisional Acceptance Certificate (PAC) of the
Development first project (in case of contract award) and from
Phone - 001-585-263-7700 the date of first delivery in case of direct material
Email ID - [email protected] supply order shall be provided as confirmed by
Contact Person Email ID - the manufacturer through their letter #Nil dated
[email protected] , January 06, 2016.
[email protected]
Website - www.ametekpower.com

ERL PHASE POWER TECHNOLOGIES Based on S&SD letter # 16-01354-030504401


LTD dated March 16, 2016, it is pre-qualified for
CANADA DYNAMIC SYSTEM
MONITORING EQUIPMENTS confirming to
74 Scurfield Blvd, Winnipeg, Mb SEC/National Grid SA Specification 38-TMSS-06,
Canada R3Y 1G4 with the following conditions: -

Contact Person - Mr. Ramaswami • Ten (10) years extended warranty in respect of
Bharath defects due to design , manufacturing, installation
Phone - +204-477-0591 , and workmanship from the date of PAC of the
Email ID - [email protected] first turnkey project (in case of contract award)
Website - http://www.erlphase.com or from the date of first delivery of direct material
supply order as confirmed by the manufacturer
through their letter # Nil dated February 19, 2014.

13. 6 Page 377 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KoCos Messtechnik Germany Mohammed Al-Ojaimi SHERLOG CRX •Fault Record PQ letter:
GERMANY Contracting Est. System Report # Based on S&SD letter # 17-06723-030504401
KoCoS Messtechnik AG (E170309E1) by dated October 31, 2017, KoCos Messtechnik
Plant -Korbach, Germany Suedring 42 Phoenix TestLab – Germany is pre-qualified for Dynamic System
D-34497 Korbach, Germany Monitor (DSM) as conforming to latest National
KoCoS Messtechnik AG Germany •DFR & DSM Report Grid SA specification # 38-TMSS-06
Suedring 42 Tel. +49 5631 9596-0 # (U170309E1) by
D-34497 Korbach, Germany [email protected] Phoenix TestLab – WARRANTY:
Germany Ten (10) years extended warranty/guarantee in
Korbach •Functional Test respect of defects due to design, manufacture,
Report # Nill by installation and workmanship from the date of
Contact Person - KoCos Germany KoCos Messtechnik Provisional Acceptance Certificate (PAC) of the
(Lea-Sophie Kotthoff, Sales), Local - Germany first turnkey project in case of contract award or
Agent- Mohammed Al-Ojaimi date of first delivery in case of direct material
Contracting Est. (Abbad S. Ahmed, supply order, as confirmed by the manufacturer
Manager Energy Services.) vide letter # Nil, dated October 08, 2015.
Phone - Tel. +49 5631 9596-0
Email ID - [email protected]
Contact Person Email ID -
[email protected]
[email protected]
Website - www.kocos.com

DIGSILENT GMBH
GERMANY

Website - http://www.digsilent.de/

POWER TECHNOLOGY INC. (PTI)


United States

Website -
http://www.powertechnology.com/

13. 6 Page 378 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

QUALITROL HATHAWAY Adwan Marketing Co. PQ Letter


NORTHERN IRELAND (AMC) Based on S&SD Letter 12-03055-01-30504401
PO Box 64273, Riyadh dated August 26, 2012, it is pre-qualified for
Plant -Belfast 11536 Dynamic System Monitoring (DSM) as conforming
Kingdom of Saudi Arabia to SEC Specification # 38-TMSS-06, with the
15 Wildflower Way, Belfast, BT12 6TA. +966-11-495-5332 following condition.
UK Ext:112
[email protected] WARRANTY
Belfast om Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Contact Person - Craig Sommerville installation & workmanship from the date of
Phone - +44 1415 721251; +44 7703 Provisional Acceptance Certificate (PAC) of the
685829; first turnkey project in case of contract award or
Contact Person Email ID - date of delivery in case of direct material supply
[email protected] order, as confirmed by the manufacturer thru
Website - www.qualitrolcorp.com letter #nil, dt:May 18, 2010.

Total = 6

POWER LINE CARRIER, SUPERVISORY CONTROL


13. 7
ON-LINE PARTIAL DISCHARGE MONITORING SYSTEM Applicable Standards: 38-TMSS-07

13. 7 Page 379 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

POWER DIAGNOSTIX SYSTEMS GMBH PDM PEHLA # 16005Ba, Based on S&SD letter # 16-05170/01-30504401
GERMANY dated 17-02-2016, dated June 23, 2016, it is prequalified for Partial
Type PDMAR 120S, PDMAR56S, PD system dated Discharge Monitoring System without UHF
Plant -. PDMCR 12-02-2016, PD Sensors as conforming to National Grid SA
system dated Material Specification 38-TMSS-07 with the
Vaalser Strasse 250, D-52064 16-02-2016, following condition:
Aachen Germany TUV Rheinland #
21248037-002, •Ten (10) years extended warranty from the date
Contact Person - Mr. Markus Soller dated of PAC of the turnkey project in case of contract
Contact Person Email ID - 19-23-02-2016, award and date of delivery in case of direct
[email protected] [email protected] TUV Rheinland # material supply order, as confirmed by the
Website - WWW.pdix.com 21248033_003, manufacturer through letter # Nil dated
dated 31-03-2014.
23-24-02-2016,
EMC Test NRW #
P12-Z-00353-002,
dated 25-02-2016,
KERI #
2014TS02444, dated
18-09-2014

13. 7 Page 380 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE Grid Solution SAS (GE & Alstom UHF sensor type: G6 GE # TR 02/2019, PQ Letter
Joint Venture) dated 18-02-2019, Based on S&SD letter # 22-00883/01-30504401
FRANCE PD Monitoring System: PD watch GE # TS0708, dated December 27, 2022, the manufacturer is
UHF100 DATED 07-09-2018, prequalified for PD Monitoring system Type “PD
Plant -Aix-Les Bains, France AEMC lab # watch UHF100 & UHF Sensor type G6” as
R1803122C-E-A2,, confirming to National Grid SA specification
GE Grid Solution SAS (GE & Alstom dated 21 Nov: 2018, #38-TMSS-07, with the following conditions:
Joint Venture), 1, Rue Paul Doumer ADETESTS #
73100 Aix-Les-Bains (France) R-ADE-ENN-18-3002
02-2/A(02), dated WARRANTY
Aix-Les Bains 25/10/2018, AEMC Ten (10) years extended warranty from the date
lab # of PAC of the first turnkey project (in case of
Contact Person - Mr. Zinedine RABAH R1803122C-E-A2, contract award) or date of first delivery (in case
Phone - +33(0) 4 79 88 79 80 + 971 4 21 Nov: 2018, LCIE # of direct material supply order), as confirmed,
4299 651 13182352-774299-A through their Letter #Nil dated March 1, 2022,
, dated 17-12-2021, shall be applicable for the equipment to be
ADETESTS # supplied to SEC/National Grid SA.
R-ADE-ENN-18-3001
77-3/A (02), dated
13th July, 2018,
Environne’tech,
France #
RENV-ENN-18-4001
19-3/A (00), dated
29-11-2018,
Environne’tech,
France # AREV L
18865-11, dated
21-11-2011 & KEMA
# 74104603-OPE/INC
14-1540, dated
09-05-2014

13. 7 Page 381 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB Power Equipment (Xiamen) ABB Electrical Industries UHF Partial Discharge Sensor Type ABB, China has PQ letter:
Company Limited, Zhangzhou Branch. Co. Ltd. WB14 rated for 145kV successfully Based on S&SD letter # 18-00461-2-30504401
CHINA P.O. Box 8796 Riyadh completed type tests dated February 25, 2018, ABB Power Equipment
11492 – Kingdom of on 1 Partial (Xiamen) Company Limited, Zhangzhou Branch -
Plant -China Saudi Arabia discharge Sensors China is pre-qualified for UHF Partial Discharge
+966 11 2653030 Type WB14 rated for Sensor Type WB14 rated for 145kV as
Wenpu Industrial Park, Taiwanese [email protected] 145kV at conforming to latest National Grid SA
Investment Zone, bb.com Independent testing specification # 38-TMSS-07
Zhangzhou, Fujian, P.R.China Postal laboratory PEHLA –
code: 363107 Germany during 09 WARRANTY:
to 12 May 2016. • Ten (10) years extended warranty/guarantee in
Zhangzhou respect of defects due to design, manufacture,
installation and workmanship from the date of
Contact Person - Ms. Jocelyn-Lihua Provisional Acceptance Certificate (PAC) of the
Ying first turnkey project in case of contract award or
Phone - +86 (0)596 5022001 , +86 date of first delivery in case of direct material
(0)18150892388 supply order, as confirmed by the manufacturer
Email ID - Jocelyn-Lihua Ying vide letter # Nil, dated January 23, 2018.
@cn.abb.com
Contact Person Email ID - Jocelyn-Lihua
Ying @cn.abb.com

13. 7 Page 382 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TECHIMP Mejdaf Group External UHF sensor: “045HRH30” Type Test PQ letter:
ITALY Riyadh Data acquisition unit: “PD Hub 12 CH” Conducted during Based on S&SD letter # 18-01963-30504401
Hossam Elkady, Senior Control unit: “Rack 42U” November 2016 and dated May 09, 2018, TECHIMP– Italy is
Plant -Bologna Technical Sales Engineer January/February pre-qualified for On-line Partial Discharge
+966 (0) 583549862 & 2017 in independent Monitoring System as conforming to latest
VIA Toscana, 11c, 40069 Zola Predosa, 4109912 Ext: 119 laboratories namely National Grid SA specification # 38-TMSS-07,
Bologna, [email protected] CREI Ven S.c.a.r.l, with the following conditions:
Italy & SIQ Ljubljan,
Contact Person - Stephan Heberer Slovenia WARRANTY:
Phone - +3905119986050 Ten (10) years extended warranty/guarantee in
Email ID - [email protected] CERI Ven S.c.ar.l , respect of defects due to design, manufacture,
Contact Person Email ID - Italy # 170516LP, installation & workmanship from the date of
Stephan.heberer@ altanova-group.com dated 27-02-2017, Provisional Acceptance Certificate (PAC) of the
Website - www.techimp.com CERI Ven S.c.ar.l , first turnkey project in case of contract award or
Italy # 163402LP, date of delivery in case of direct material supply
dated 02-12-2016 order, as confirmed by TECHIMP – Italy through
SIQ Ljubljan, their letter # Nil dated February 24, 2013.
Slovenia #
T211-0003/17, dated
06-01-2017,
SIQ Ljubljan,
Slovenia #
T223-0027/17, dated
16-01-2017,
SIQ Ljubljan,
Slovenia #
T251-0004/17, dated
05-01-2017

13. 7 Page 383 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd PDMS KERI, Korea # Based on S&SD letter # 16-05296-2-30504401
SOUTH KOREA Type HiPDS-G (HiDAS) 2016TS00609, dated dated July 28,2016, it is prequalified for On-Line
09-03-2016, Partial Discharge Monitoring System (PDMS) and
Plant -Ulsan Internal Sensor KERI, Korea # Internal Sensor as conforming to National Grid SA
Type HiUC-P140 2016TS00627, dated Material Specification 38-TMSS-07 with the
1000, Bangeojinsunhwan-doro, 18 Jan: - 23 Feb: following condition:
Dong-gu, Ulsan, South Korea, 2016,
KERI # •Ten (10) years extended warranty from the date
Ulsan 2016TS00755, dated of PAC of the turnkey project in case of contract
03 -04 March, 2016. award and date of delivery in case of direct
Contact Person - Mr. J.W(Jin) Lee material supply order, as confirmed by the
Phone - +966-11-293-2026, manufacturer through letter # S370-1504-LSH3
+82-10-4818-0822 dated 31-07-2015.
Contact Person Email ID -
[email protected]
Website - Previously Hyundai Heavy Industries Co. Ltd [The
http://www.hyundaielectric.com name has been changed based on P&SFD letter
#17-04234/01-030504401 dated May 24, 2017].

Previously Hyundai Electric & Energy Systems


Co., Ltd., the name has been changed to HD
Hyundai Electric Co., Ltd

13. 7 Page 384 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

QUALITROL HATHAWAY Mr. Joudeh, Fadi Type / Model: PDMG-RH Type test witnessing Previous location was "Glasgow, Scotland", the
NORTHERN IRELAND +971 4 560 700; +971 4 with UHF sensor was successfully location has been changed to "Belfast, Ireland,
560 7955; +971 56 conducted during UK" based on letter # 23-02840-30504401 dated
Plant -Belfast 5070501 09th to 13th June 14.01.2024.
[email protected] 2014.
15 Wildflower Way, Belfast, BT12 6TA. m In following Labs, PQ Letter:
UK DMS # DR01979, S&SD letter # 15-02752-1-30504401 dated April
dated 10-06-2014, 15, 2015, the manufacturer is approved to supply
Belfast York EMC services PARTIAL DISCHARGE MONITORING SYSTEM.
# 3939TR1, dated
Contact Person - Craig Sommerville 30-09-2014, WARRANTY:
Phone - +44 1415 721251; +44 7703 Selex ES # 071408, Ten (10) years extended warranty/guarantee in
685829; dated 16-08-2014, respect of defects due to design, manufacture,
Contact Person Email ID - Selex ES # installation & workmanship from the date of
[email protected] 121407_2, dated Provisional Acceptance Certificate (PAC) of the
Website - www.qualitrolcorp.com 13-08-2014, first turnkey project in case of contract award or
CRANAGE # E8909, date of delivery in case of direct material supply
dated 26-08-2014, order, as confirmed by the manufacturer thru
CRANAGE # letter #nil, dt: Jan 14, 2013.
E8922R, Dated
09-10-2014,
TUV # 75927584,
dated August, 2014
KEMA # 30107057-
dated 11-01-2011

13. 7 Page 385 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

APM TECHNOLOGIES INC APM Technologies KSA Type / Model: (PDMS) APM5000 & KERI # PQ Letter:
SOUTH KOREA APM Technologies KSA - APM2000 (Portable) 2014TS02416, dated S&SD letter # 14-08866-2-30504401 dated
Riyadh Second Industrial with UHF sensor 05 Aug, 2014, KERI December 11, 2014, it is pre-qualified for Partial
Plant -Seoul, Korea Republic Of City, # 2014TS02423, Discharge Monitoring System (PDMS).
Riyadh Saudi Arabia dated 05 Aug, 2014,
Mercedes-Benz Building 5F, 225-5, +966 53 66 77 212 KERI # WARRANTY:
Nonhyeon-Dong, Gangnam-Gu, Seoul [email protected] 2014TS02444, dated Ten (10) years extended warranty/guarantee in
135-829, Korea 18-09-2014, KERI # respect of defects due to design, manufacture,
2014TS02568, dated installation & workmanship from the date of
Contact Person - Mr. JAY PARK 18 Aug. – 17 Sept. Provisional Acceptance Certificate (PAC) of the
Phone - + 82 2 545 6286,Mobile: +82 10 2014, KERI # first turnkey project in case of contract award or
5157 1255 2014TS02569, dated date of delivery in case of direct material supply
Email ID - [email protected] 11 Aug- 15 Sept, order, as confirmed by the manufacturer thru
[email protected] 2014, letter #nil, dt: May 12, 2014.
Website - http://www.apmtech,co,kr KOLAS #
STC-B14-375-01,
dated 18-22 –
09-2014, KOLAS,
Korea #
STC-B14-375-02,
dated 15-09-2014,
STC-B14-375-03,
dated
18-19-09-2014.

13. 7 Page 386 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES PD Monitoring System ,Type: GM-3000 Type tested in the PQ letter
CORPORATION (HICO) UHF Internal sensor presence of Based on S&SD letter # 15-09060-02-30504401
SOUTH KOREA type HiCMS-GM-IS, external Sensors SEC/National Grid dated December 09, 2015, it is pre-qualified for
type HiCMS-GEP-S-2, SA Engineers and PDM & Sensors with the following conditions:
Plant -Republic of Changwon, Korea UHF Noise sensor third party inspector
Type HiCMS-GNP-S-2 at KERI WARRANTY:
Eric Rhie, 450, Gongdeok-Dong, KERI, Korea # Ten (10) years Extended Guarantee / Warranty
Mapo-Gu, Seoul , Korea 2015TS02273, dated from the date of PAC of first Project (in case of
Tel:82-707-6180 10-11, August, contract award) or from the date of delivery for
2015, KERI, Korea # the direct material supply order. This is applicable
Contact Person - Mr. Jason Kang; Sale 2015TS02274, dated from first project and subsequently reduced
Manager & Mr. Young Kim; Sales 10-11, August, yearly in case of future project. This was
Manager 2015, KERI, Korea # confirmed, through their Letter No.
Contact Person Email ID - 2015TS02275, dated HS-PQ-150511-PDM-001 dated 17/07/2015.
[email protected] , 10, August, 2015,
[email protected] Keri # 2015TS02508
Website - DATED 05-27
http://www.hyosung.co.kr/eng/index.js august, 2015, Korea
p?, www.hyosung.com testing & Research
Institute,
Korea #
CUS2015-3092,
dated 17-19 August,
2015, Korea testing
& Research Institute,
Korea #
KOMERI-0306-15T24
16-1, dated 20-21,
August, 2015

13. 7 Page 387 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB S.R.O (RFF) ABB Automation CO. Ltd. UHF Sensor Type WB3 (1HC0034454) PHELA # 15020Ba PQ Letter:
CZECH REPUBLIC Saudi Arabia rated for 300/420 kV dated 14-16 April, Based on S&SD letter # 17-03926-2-30504401
PO Box # 414: 2015, PHELA # dated August 03, 2017, ABB S.R.O LBU Brno
Stetkova 1638/18,140 00 Praha 4Czech Riyadh-11383 15015Ba-1, dated Factory – Czech Republic is pre-qualified for
Republic-Trutnov +966 (11) 2653030, 08-17 April, 2015, Partial Discharge Sensor (UHF Sensor) type WB3
+966504401696 ABB, Switzerland # (1HC0034454) rated for 300/420 kV as
Contact Person - Mr. Essam [email protected] HASH650969E, conforming to National Grid SA specification #
Bashraheel & Mr Aref Al-Arrak bb.com dated 04-06, March, 38-TMSS-07 Rev.0 with the following conditions:
Email ID - 2014
[email protected] WARRANTY:
&[email protected] •Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #
PGHV-17-04-26/GIS-1 dated June 16, 2017.

Total = 9

POWER LINE CARRIER, SUPERVISORY CONTROL


13. 8
COUPLING CAPACITOR VOLTAGE TRANSFORMER (CCVT)/ CAPACITOR VOLTAGE Applicable Standards: 38-TMSS-08,50-TMSS-02
TRANSFORMER (CVT) up to 380KV
NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

13. 8 Page 388 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELECTROTECNICA ARTECHE HNOS. Type / Model: Capacitive Voltage 1- For type 1- Type DDB-170
S.L./ E.A.H.S.L Transformer DDB-170, Test PQ Letter:
SPAIN Report # 2010 10 3D S&SD Letter 12-03192-02-30504001 dated
1 - DDB-72 0571 February 19, 2012, pre-qualified for CVT
Plant -Mungia, Spain Rating Capacitor Voltage Transformer up to 132 kV.
69 kV 2- For type
Electrotecnica Arteche Hnos. S.L./ DFK-420, " The first WARRANTY:
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea 2 - DDB-170 batch of 380kV Ten (10) years extended warranty/guarantee in
Nº28 48100/ Rating: Capacitor Voltage respect of defects due to design, manufacture,
132kV, CCVT Transformer (CVTs) installation & workmanship from the date of
Contact Person - Mr. Roberto Antuñano type DFK-420 per Provisional Acceptance Certificate (PAC) of the
Phone - +946011200 3 - DFK-245 50-TMSS-01, Rev.01 first turnkey project in case of contract award or
Email ID - [email protected] Rating: to be supplied to date of delivery in case of direct material supply
Website - http://www.arteche.es 230kV, CVT SEC/National Grid order, as confirmed by the manufacturer thru
SA shall be type letter #nil, dt: jan 11, 2010.
4 - DFK-420 tested in an
Rating: accredited test 2- Type DFK-420
up to 380kV, CVT laboratory in PQ Letter
presence of three Based on S&SD letter MPQ # 10816213 dated
(3) SEC/National January 7, 2018, Electrotecnica ARTECHE
Grid SA and one (1) Hermanos, S.L. - Mungia, Spain is pre-qualified
SEC/National Grid for 380kV Capacitor Voltage Transformers
SA approved IIA (CVTs), type DFK-420 as conforming to National
Inspector as Grid SA specification # 50-TMSS-0,Rev.0, with
conformed through the following conditions:
Manufacturer Letter
# Nil dated Warranty
December 03,2017." Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
3. For type DFK-245, contract award) or date of first delivery (in case
Test Report # 2020 of direct material supply order), as confirmed,
01 3D 0021 through their letter # Nil, dated July 21, 2016 shall
be applicable for all 380kV Capacitor Voltage
4. For type DDB-72, Transformers (CVTs), type DFK-420 to be
The first batch of supplied to SEC/National Grid SA.
type DDB-72 to be
supplied to 3- Type DFK-245
SEC/National Grid PQ Letter:
SA shall be type Based on S&SD letter # 18-02331-030504401
tested in an dated July 8, 2018 Electrotecnica ARTECHE
accredited test Hermanos, S.L. - Mungia, Spain is pre-qualified
laboratory in for 230kV Capacitor Voltage Transformers

13. 8 Page 389 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

presence of three (CVTs), type DFK-245 as conforming to National


(3) SEC/National Grid SA specification # 50-TMSS-02 , with the
Grid SA and one (1) following conditions:
SEC/National Grid
SA approved IIA Warranty:
Inspector Ten (10) years extended warranty/guaranty from
the date of PAC of the first turnkey project (in
case of contract award) and from the date of
delivery (in case of direct material supply order),
as confirmed, through their letter # Nil, dated July
2, 2018 shall be applicable for all 230kV
Capacitor Voltage Transformers (CVTs), type
DFK-245 to be supplied to SEC/National Grid SA.

4.

PFIFFNER Type / Model: CT & CVT PQ Letter:


SWITZERLAND TS&SD letter# 09-01105-03032301 dated 24th
Rating: up to 380kV June 2009, pre-qualified for CT (50-TMSS-01)&
Website - http://www.pfiffner.com/ CVT (50-TMSS-02) rated up to 380Kv

CONDITION:
All type, routine & special tests including the load
test shall be carried out on the first batch to be
supplied to SEC in securing an order in an
independent testing laboratory in the presence of
three (3) SEC engineers & one (1) approved
independent inspection agency Inspector.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

13. 8 Page 390 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE
United States

Plant -United States

Website - http://www.ge.com/

KONCAR INSTRUMENT Nesma Telecom & Type / Model: PQ Letter:


TRANSFORMERS INC. Technology Co. Ltd. Limited up to 132kV only.
CROATIA Nesma Telecom & Rating: Limited up to 132kV
Technology Co. Ltd. CONDITION:
Plant -Zagreb, Hrvatska, Croatia (NESMA ELECTRIC), All Type, Special, Routine tests per SEC
Jeddah, Asfan Road Standards and IEC to be performed at
Josipa Mokrovica 10; HR-10090 inside azzam compound KONCAR-Electrical Institute Inc. as independent
Zagreb, Croatia +966 12 422 9750 Ext. and accredited testing laboratory
3522 +966506513637
Contact Person - Mr. Marcel Folnović , Rayan Alamoudi WARRANTY:
Area Manager- Sales & Marketing [email protected] Ten (10) years extended warranty/guarantee in
Department respect of defects due to design, manufacture,
Phone - +385 1 379 5240, +385 1 379 installation & workmanship from the date of
4112 Mob: +385 99 249 3039 Provisional Acceptance Certificate (PAC) of the
Email ID - first turnkey project in case of contract award or
[email protected] date of delivery in case of direct material supply
Website - http://www.koncar-mjt.hr order.

HAEFELY-TRENCH ELECTRIC
CANADA

Website -
http://www.electricityforum.com/produ
cts/htg.htm

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

13. 8 Page 391 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PASSONI & VILLA


ITALY

Website -
http://www.passoni-villa.com

RITZ TYPE TEST REQUIRED IN FIRST SUPPLY


United States

Website - http://www.ritzusa.com/

TRENCH ITALIA PREVIOUSLY AS VA TECH (NOUVA MAGRINI


ITALY GALILEO)

Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html

ABB HV TECHNOLOGIES
Swaziland

Plant -Jurastrasse 45,Ch-5430


Wettingen, Switzerlandaddress: Doser,
Jurastrasse 45, Ch-5430 Wettingen,
Switzerland

Esentepe Mahallesi, Milangaz Cad No.


52 Kartal 34870, Istanbul -Turkey

Contact Person - Mr. Bernhard


Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - http://www.abb.ch/

13. 8 Page 392 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Hitachi Energy Sweden AB Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

Total = 12

METERS
14. 1
METERING DEVICES (KILOWATT HOUR METER ENERGY METER) Applicable Standards: 40-TMSS-02

Elster Rometrics SRL ITS – Ideal Technical Meters type A1800 with models A1884 Type tests PQ Letter:
Romania Solutions RALNC, A1822 RALNC, A1860 RALC. successfully Based on S&SD letter # MPQ #13226714 dated
3135 Prince Sultan Bin completed on 22-29 March 17, 2022., the manufacturer is prequalified
Plant -Romania Abdulaziz Rd, As April 2019 in for METERING DEVICES (KILOWATT HOUR
Sulimaniyah, Riyadh DNV-GL (KEMA) METER ENERGY METER), as conforming to
Timisoara Airport Park 12232 7908 report #1019-20 & National Grid SA specification #40-TMSS-02, with
307210 Giarmata +966 56 666 2660 72129424. the following conditions:
Timis county [email protected]
Romania WARRANTY:
Ten (10) years extended warranty from the date
Contact Person - Maritass Comia of PAC of the first turnkey project (in case of
Phone - +40 256 49 98 99 contract award) or date of first delivery (in case
Email ID - [email protected] of direct material supply order), as confirmed,
Contact Person Email ID - through their Letter # Nil dated April 10, 2017 shall
[email protected] be applicable for the equipment to be supplied to
Website - www.elstersolutions.com SEC/National Grid SA.

14. 1 Page 393 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Secure Meters Limited Rezayat Trading Model: APEX 200 PQ Letter


INDIA Company Limited Type: P3E Based on S&SD letter # MPQ#99346714 dated
Sudhagar Nadarajan, October 22, 2023, the manufacturer is
Plant -India Commercial Manager – prequalified for Revenue Meters as confirming to
E&I Division National Grid SA specification # 40-TMSS-03 with
SECURE METERS LIMITED, PO Box 90, Al Khobar following conditions:
PRATAPNAGAR INDUSTRIAL AREA , 31952, KSA
UDAIPUR-313003, RAJASTHAN Phone: TYPE TEST:
+966-13-663-6000 Ext. Fresh Type Test to be conducted for the First
Contact Person - Sandeep Jadhav 4009 Project in Independent accredited laboratory in
Phone - +971561718333/ +971 4 Mobile: 00966 the presence of three (3) SEC/National Grid SA
2045311 555737286 Engineers and one (1) SEC/ National Grid SA
Email ID - Web: approved 3rd Party Inspector for which the entire
[email protected] www.rezayat-commerci cost shall be borne by manufacturer. Fresh Type
Contact Person Email ID - al.com Test was confirmed by manufacturer through
[email protected] their Letter # SEC/SECURE/PQL/PR/BEJ-1006-02
Website - www.securemeters.com dated 05.March.2021.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for Revenue Meters in
respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # SEC/SECURE/PQL/PR/BEJ-1005-02
dated 17.October.2021.

14. 1 Page 394 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS
GERMANY

Plant -Berlin. Germany

Freyeslebenstr 1 91058 Erlangen

Contact Person - Mr. Yaser Salih


Phone - +49-9131725216
Email ID - [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

ADVANCE ELECTRONICS CO., LTD. Type: USM-1 Type tests were PQ Letter
Saudi Arabia conducted in NMI Based on S&SD letter#19-00093-1-30504401
laboratory – dated January 27, 2019, the manufacturer is
Riyadh , Saudi Arabia Netherland prequalified for Metering Devices (Kilowatt Hour
30/04-11/05,2018 Meter, Energy Meter) as confirming to SEC
[email protected] and 19-22/11,2018. specification #40-TMSS-02 Rev.0, with the
+966 11 220 1350 EX. 2357 following conditions:

WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #Nil dated
January 09, 2019.

14. 1 Page 395 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELSTER , ITS A3RAQ meters with configuration kEMA, Elster PREVIOUSLY ABB (T &D)
United States Riyadh KSA ZD3D44F00LD-16, ZD3E44F00LD-16, Engineering report
Phone - ZD3D46000LD-16. Test Date - Aug Based on S&SD Letter 12-00932-1-30504401
Plant -Raleigh, Nc,USA +966-56-666-2660 2011, Feb 2005 dated March 25, 2012, it is pre-qualified for
Email - A1860RALC meters with configuration Test Report No. - A3RAQ, A1860RALC and A1860RAL meters as
Elster Gmbh Otto-Hahn-Strasse 25 [email protected] ZE3KM4CF5LK-EL. 71240276-TIC confirming to SEC Specification # 40-TMSS-02,
D-68623 Lampertheim, Germany 6996-11, Rev.0 with the following condition:
Raleigh, Nc , United States A1860RAL meters with configuration PAKR-8ZNRH
ZE3KM4CF0LH-EL. Free Supply of Meter Type A3RAQ: Five (5)
Contact Person - Mr. Ali Mouslmani Revenue Meters Type A3RAQ shall be supplied
Email ID - [email protected] free of cost to SEC as confirmed through ELSTER
Website - http://www.elster.com/ letter # L1-ST12-001 dated January 21, 2012.

WARRANTY
Five (5) extended warranty/guarantee in respect
of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: 12-01-2012.

GEC MEASUREMENT
United Kingdom

Website -
http://www.gecinstruments.com/

14. 1 Page 396 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LANDIS + GYR AG-ZUG Saudi Masar High Tech Type/Model - [(E650 (ZXD) & E850 ZXQ Test Report No. - Based on S&SD Letter 14-04075-30504401 dated
SWITZERLAND Marketing Co. Rating - Cl 0.2s Active Cl 0.5 Reactive Yes April 2014 July 01, 2014, it is pre-qualified for Revenue
Industrial City, Phase 3, Meters Type E650 (ZXD) & E850 (ZXQ)
Landis+Gyr Ag Zug/Switzerland Jeddah CR No conforming to National Grid SA specifications #
Theilerstr. 1 63O1 Zug,Switzerland. 4030118442, 40-TMSS-03, Rev.1 and 40-TMSS-02 Rev.0 with
Zug , Switzerland Phone - 0096612608 the following conditions:
0581
Contact Person - Mr. Akhlak WARRANTY
Husain,Area Manager. Ten (10) years extended warranty/guarantee in
Phone - +971 558854159 respect of defects due to design, manufacture,
Email ID - [email protected] installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 30, 2014.

Software for both meters [(E650 (ZXD) & E850


(ZXQ)] shall be MAP120 and MAP110 .

ISKRA MIS Acceptance subjected to successful product


SLOVENIA evaluation / acceptance by sec concerned end
user department for each purchase order /
Kranj , Slovenia project during tender/bidding stage.

LANDIS + GYR AG SAUDI MASAR E650-ZMD402CT44.0459 S3 Landis + Gyr AG - PQ letter:


Greece HIGH-TECH & Software for E650 meter are MAP120 Greece Based on S&SD letter # 17-04020-1-30504401
MARKETING CO. and MAP110 successfully dated May 16, 2017, Landis + Gyr AG- Greece is
Plant -Greece P.O Box 990, Jeddah conducted type pre-qualified for Revenue Meters (type
21421, KSA tests on Revenue E650-ZMD402CT44.0459 S3) as conforming to
78km National Road Athens-Corinth, P. +966 Meters (type National Grid SA specification # 40-TMSS-02,
O Box 207 GR- 201 00 Corinth, Greece 920005711/6133099 E650-ZMD402CT44. Rev.0, with the following conditions:
[email protected] 0459 S3) in
Contact Person - Mr. Akhlak Husain m.sa independent test
Phone - +971 4 452 66 26 laboratory (Quinel & WARRANTY:
Email ID - Metas) in the •Ten (10) years extended warranty from the date
[email protected] presence of two (2) of PAC of the project (in case of contract award)
Contact Person Email ID - SEC/National Grid or date of delivery (in case of direct material
[email protected] SA Engineers & supply order), as confirmed, through their Letter
Website - www.landisgyr.com Third Party inspector No. NIL dated May 11, 2016 shall be applicable for
(test report copy all Revenue Meters (type
enclosed). E650-ZMD402CT44.0459 S3) to be supplied to
SEC/National Grid SA.

14. 1 Page 397 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TYCO ELECTRONICS LTD ( Type/Model: Based on TS&SD Letters


CROMPTON INSTRUMENTS) (08-F00975/01-03032301 dated June 04, 2008),
United Kingdom Integra (1530, 1540, &1630) (10-F00230/01-03032301 dated February 03,
2010) & (11-F03017/01-03032301 dated October
Website - 16, 2011). Integra (1530, 1540, &1630) are
http://www.tycoelectronics.com/ prequalified for Digital Metering Devices ( NOT
FOR BULK ENERGY METERS) as confirming to
SEC Specification # 40-TMSS-02, with the
following condition:

WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by TYCO Electronic UK
through their letter # INT-SEC-06 dated January
03, 2008 and its Amendment dated Nov 21, 2011.

Total = 10

METERS
14. 2
METERING DEVICES (AMMETER, VOLTMETER, MW, MVAR) Applicable Standards: 40-TMSS-02

AREVA
FRANCE

Plant -France

Website - http://www.areva.com/

CELSA, ITALY
ITALY

Italy

Website - http://www.celsa.com/

14. 2 Page 398 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Secure Meters (Sweden) AB Previously CEWE Sweden, the name has been
ITALY changed to SECURE METERS (Sweden) AB

Piazza Manifattura, 1
38068 Rovereto (TN)

Rovereto

Contact Person - Sandeep Jadhav


Phone - +971561718333/ +971 4
2045618
Email ID -
[email protected]
Contact Person Email ID -
[email protected]
Website - www.securemeters.com

ISKRA MIS ACCEPTANCE SUBJECTED TO SUCCESSFUL


SLOVENIA PRODUCT EVALUATION / ACCEPTANCE BY SEC
CONCERNED END USER DEPARTMENT FOR EACH
Kranj , Slovenia PURCHASE ORDER / PROJECT DURING
TENDER/BIDDING STAGE.

ENTES Type/Model PQ Letter


TURKEY Based on TS&SD letter # 10-F2298/03-03032301
Digital Ammeter type (EPM-34) and dated 02/10/2010, it is pre-qualified for Digital
Istanbul , Turkey Digital Voltmeter type (EVM-35) Ammeter type (EPM-34) and Digital Voltmeter type
(EVM-35) as conforming to SEC specification #
40-TMSS-02, Rev.0 with the following condition:

WARRANTY
ENTES (Turkey) has agreed to give SEC a
Guarantee/ Warranty on the proposed digital
meters for a period of two (02) years and eight
(08) years (for maintenance) for total of ten (10)
years from the date of PAC of the turnkey project
in case of contract award or date of delivery in
case of direct material supply order.

14. 2 Page 399 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SCHNEIDER ELECTRIC Schneider Electric Type/Model - ION 6200 DIGITAL POWER METERS TYPE ION 6200 (0.5%
CANADA Contact Rating - upto 600V 0-5 amps 0.5 ACCURACY CLASS);
Person:Senthilkumar Kp accuracy class
Plant -Victoria, Canada senthilkumar.kp@schnei WARRANTY
der-electric.com ( and ) Ten (10) years extended warranty/guarantee in
2195 Keating Cross Road Saanichton ahm respect of defects due to design, manufacture,
British Columbia Canada V8M 2A5 installation & workmanship from the date of
Canada Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Email ID - date of delivery in case of direct material supply
[email protected] order.
Website -
http://www.schneider-electric.ca/
http://www/en/html/frontpage.htm

TYCO ELECTRONICS LTD ( Type/Model: PQ Letter


CROMPTON INSTRUMENTS) Based on TS&SD Letters
United Kingdom Integra (1530, 1540, &1630) (08-F00975/01-03032301 dated June 04, 2008),
(10-F00230/01-03032301 dated February 03,
Website - 2010) & (11-F03017/01-03032301 dated October
http://www.tycoelectronics.com/ 16, 2011). Integra (1530, 1540, &1630) are
prequalified for Digital Metering Devices as
confirming to SEC Specification # 40-TMSS-02,
Rev.0 with the following condition:

WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by TYCO Electronic UK
through their letter #INT-SEC-06 dated January
03, 2008 and its Amendment dated Nov 21, 2011.

Total = 7

METERS
14. 3
AUTOMATIC METER READING (AMR) SYSTEM INTEGRATOR, AUTOMATIC METER READING Applicable Standards: 40-TMSS-03 (Rev.0)
(AMR) SYSTEM

14. 3 Page 400 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ADVANCE ELECTRONICS CO., LTD. Based on approval of Executive Directive for


Saudi Arabia TS&SD Letter # 08-1105-03032301 dated
20/10/2008, it is pre-qualified for Quality Meters
Riyadh , Saudi Arabia Type(SEL-734).

[email protected]
+966 11 220 1350 EX. 2357

MEMF Ideal Technical Solutions Previously " Ideal Technical Solutions (ITS)", the
(MEMFITS) name has been changed to "MEMF Ideal Technical
Saudi Arabia Solutions (MEMFITS)"

Saudi Arabia-Riyadh PQ Letter


Based on S&SD Letter 13-00971-1-30504401
dated May 15, 2013, it is pre-qualified for AMR
system with Revenue Meter & Power Quality
Meter as conforming to National Grid SA
Specification # 40-TMSS-03, Rev.0 with the
following conditions:

WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery in case
of direct material supply order as confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter # W1-NG01-J13-001 dated January
08, 2013 and L1-ST12-020 dated December 03,
2012.

ITS Integration & Test Facility: as per item# 3.a of


ITS letter# L1-NG01-J13-003 dated January 26,
2013.

Total = 2

METERS
14. 4
ADVANCED METERING INFRASTRUCTURE (AMI) SYSTEM INTEGRATOR Applicable Standards: 40-TMSS-03 (Rev.01)

14. 4 Page 401 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Innovative Systems Co. Ltd. PQ Letter


Saudi Arabia
Based on S&SD Letter #MPQ88136614-Class I(b)
Plant -Riyadh KSA -2020 dated January 03, 2022, the manufacturer
is prequalified for ADVANCED METERING
Innovative Systems - Street No. 20 INFRASTRUCTURE (AMI) SYSTEM INTEGRATOR
Along Street 59 Al Kharj Industrial City as conforming to National Grid SA specification
Riyadh Saudi Arabia #40-TMSS-03 (Rev.01), with the following
conditions:
Riyadh
Warranty:
Contact Person - Kamal Al Muhanna, Ten (10) years extended warranty from the date
CEO Rameez Mulki Substation of PAC of the first turnkey project (in case of
Automation BU Manager contract award) or date of first delivery (in case
Phone - +966114608160/61 of direct material supply order). as confirmed,
Email ID - [email protected] through their letter No. Nil, dated October 28,
[email protected] 2020, shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

TIEPCO AMI System Successfully PQ letter:


Saudi Arabia complete evaluation Based on S&SD letter # 17-07807-1-30504401
of field Demo in dated December 07, 2017, TIEPCO Dammam is
Plant -Tiepco Factory Die-Ii Dammam TIPCO factory, pre-qualified for AMI System as conforming to
Saudi Arabia, Dammam during 27 latest National Grid SA specification #
& 28 September 40-TMSS-03 Rev.01
Post Box 2705 Dammam Saudi Arabia, 2017 in presence of
Dammam , Saudi Arabia SEC/National Grid SUB SUPPLIERS:
SA. Power Quality Meters, Revenue Meters, Ethernet
Contact Person - Mr. Aamar Saeed GM Switches & other subassemblies of AMI shall be
Sales procured from SEC/National Grid SA Approved
Phone - +966-6380080 Manufacturers list.
Email ID - [email protected]
Website - http://www.tiepco.com WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated November 22, 2017.

14. 4 Page 402 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

WESCOSA Revenue Meters type E850 from PQ letter:


Saudi Arabia LANDIS & GYR Switzerland & Power Based on S&SD letter # 18-00961-2-30504401
Quality Meters type Nexus 1500 from dated March 12, 2018 WESCOSA-Dammam, KSA
Plant -Dammam , Saudi Arabia ElG Tech USA is pre-qualified for Advance Metering
Infrastructure (AMI) System as conforming to
First Industrial City of Dammam, P.O. National Grid SA specification # 40-TMSS-03,
Box 2389, Dammam 31451, Saudi Rev.01 with the following conditions:
Arabia
WARRANTY:
Contact Person - +966500594704 •Ten (10) years extended warranty/guarantee in
Phone - +966138100234 Ext 3267 respect of defects due to design, manufacture,
Email ID - [email protected] , installation and workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
Website - http://www.wescosa.com/ first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # APSS-WI-10-15-008 , dated October
20, 2015.

14. 4 Page 403 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ADVANCE ELECTRONICS CO., LTD. AMI Demo PQ Letter


Saudi Arabia conducted in AEC Based on S&SD letter # MPQ77936614 dated
Factory – Riyadh on December 30, 2021, the manufacturer is
Riyadh , Saudi Arabia 05 December 2021 prequalified for ADVANCED METERING
with the presence INFRASTRUCTURE (AMI) SYSTEM INTEGRATOR,
[email protected] of SEC/National Grid ADVANCED METERING INFRASTRUCTURE (AMI)
+966 11 220 1350 EX. 2357 SA. as conforming to National Grid SA specification
#40-TMSS-03 Rev.01, with the following
conditions:

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
or date of first delivery (in case of direct material
supply order), as confirmed, through their Letter
#AEC 65/2/16/298 dated August 08, 2020 shall be
applicable for the equipment to be supplied to
SEC/National Grid SA.

AMI Factory Acceptance Test


To conduct the FAT as per the submitted
compliance statement of ITP-AMI-02 Rev.0 and as
per approved test procedure and acceptance
criteria for each test. AEC to comply all the
comments raised during DEMO and
communicated through S&SD email dated
23.12.2021 which will be verified during AMI Pilot
Project.

14. 4 Page 404 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.

Plant -2Nd Industrial Area,Riyadh,, Previous name was ABB Electrical Industries
Company Ltd, and changed to ABB Contracting
Po Box 325841 Riyadh,11371 KSA Co. Ltd based on S&SD letter
#20-01681-30504401 dated October 01, 2020
Riyadh
Based on S&SD Letter 16-09613-1-30504401
Contact Person - Mr. Ahmed Abubasha dated Dec 12, 2016, it is pre-qualified for AMI
Contact Person Email ID - system with as conforming to National Grid SA
[email protected] Specification # 40-TMSS-03, Rev.01 with the
following conditions:

WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter #PSN/SAS/0429/2014 dated 29 April, 2014.

14. 4 Page 405 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

System House Factory for Electrical PQ Letter


Panels (SEP)-Riyadh • Based on S&SD letter # 16-09428-2-30504401
Saudi Arabia dated December 25, 2016, The manufacturer is
prequalified to supply Advance Metering
Plant -2nd Industrial City, Riyadh, Infrastructure (AMI) as conforming to National
Kingdom of Saudi Arabia. Grid SA specification # 40-TMSS-03, Rev.01with
the following condition:
Plant A: Building No. 8557, Street No.
5807, WARRANTY
2nd Industrial City, Riyadh, Postal Code • Ten (10) years extended warranty in respect of
14334-4906, the defects due to design, manufacturing,
Kingdom of Saudi Arabia. installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
Plant B: Building No. 6687, Street No. 3, first turnkey project (in case of contract award)
Unit No. 45, and from the date of first delivery in case of
2nd Industrial City, Riyadh, Postal Code direct material supply order shall be provided as
14331-3599, confirmed by the manufacturer through their
Kingdom of Saudi Arabia. letter No. SEP/AMI/2015/06 dated September
15,2015.
Riyadh

Contact Person - Bader Alhuthayli


Phone - +966 11 498 0822
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - https://sep.com.sa

14. 4 Page 406 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MEMF Ideal Technical Solutions Previously " Ideal Technical Solutions (ITS)", the
(MEMFITS) name has been changed to "MEMF Ideal Technical
Saudi Arabia Solutions (MEMFITS)"

Saudi Arabia-Riyadh PQ Letter


Based on S&SD Letter 14-00090-1-30504401
dated January 09, 2014, it is pre-qualified for
Advance Metering Infrastructure (AMI) systems
with Revenue Meter & Power Quality Meter from
pre-qualified manufacturers as conforming to
National Grid SA Specification # 40-TMSS-03,
Rev. 01 with the following conditions:

WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery in case
of direct material supply order as confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter #W1-NG01-J14-001 dated January
01,2014 and Letter#L1-NG01-J14-001 dated
December 03, 2013.

CONDITION
System Demo: Live Demo of the AMI System will
be conducted in presence of SEC/National Grid
SA Engineers on the first system to be
manufactured in SEP factory already confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter #L1-NG01-J14-002, dated January
06,2014.

14. 4 Page 407 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL SYSTEMS PQ Letter


Saudi Arabia Based on S&SD letter # 15-03460-30504401
dated April 22, 2015, The manufacturer is
Riyadh, Saudi Arabia prequalified to supply Advance
Metering Infrastructure (AMI) as conforming to
Riyadh National Grid
SA specification # 40-TMSS-03, Rev.01with the
Contact Person - Sultan Alghamdi " VIP following
key Account Manegr "; Saleh condition:
Almehaijeen "Projects Sales Engineer "
Phone - 920006111 WARRANTY
Contact Person Email ID - Ten (10) years extended warranty in respect of
[email protected]; the defects due to design, manufacturing,
[email protected] installation and workmanship from the date of the
Website - www.alfanar.com Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter # AES-AMI-PQA-2014/001 dated July 09,
2014.

Total = 8

METERS
14. 5
REVENUE METER Applicable Standards: 40-TMSS-03

14. 5 Page 408 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Elster Rometrics SRL ITS - Ideal Technical Meters type A1800 with models A1884 Type tests PQ Letter
Romania Solutions RALNC, A1822 RALNC, A1860 RALC. successfully Based on S&SD letter #MPQ 13226714 dated
3135 Prince Sultan Bin completed in March 17, 2020, the manufacturer is prequalified
Plant -Romania Abdulaziz Rd, As DNV-GL (KEMA) for Revenue Meter as conforming to National Grid
Sulimaniyah, Riyadh report #1019-20 & SA specification # 40-TMSS-03, with the
Timisoara Airport Park 12232 7908 72129424. following conditions:
307210 Giarmata +966 566662660
Timis county [email protected] CONDITIONS
Romania The manufacturer is not allowed to quote for any
SEC/National Grid SA , project/purchase order
Contact Person - Maritass Comia whenever there is change in plant location &
Phone - +40 256 49 98 99 change in design, till evaluated and approved by
Email ID - [email protected] SEC/National Grid SA.
Contact Person Email ID - Whenever there is a change of authorized
[email protected] contact person, SEC/National Grid SA shall be
Website - www.elstersolutions.com informed with new contact details to update our
database.
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter # Nil dated April 10, 2017 shall
be applicable for the equipment to be supplied to
SEC/National Grid SA.

14. 5 Page 409 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Secure Meters Limited Rezayat Trading Model: APEX 200 PQ Letter


INDIA Company Limited Type: P3E Based on S&SD letter # MPQ#99346714 dated
Sudhagar Nadarajan, October 22, 2023, the manufacturer is
Plant -India Commercial Manager – prequalified for Revenue Meters as confirming to
E&I Division National Grid SA specification # 40-TMSS-03 with
SECURE METERS LIMITED, PO Box 90, Al Khobar following conditions:
PRATAPNAGAR INDUSTRIAL AREA , 31952, KSA
UDAIPUR-313003, RAJASTHAN Phone: TYPE TEST:
+966-13-663-6000 Ext. Fresh Type Test to be conducted for the First
Contact Person - Sandeep Jadhav 4009 Project in Independent accredited laboratory in
Phone - +971561718333/ +971 4 Mobile: 00966 the presence of three (3) SEC/National Grid SA
2045311 555737286 Engineers and one (1) SEC/ National Grid SA
Email ID - Web: approved 3rd Party Inspector for which the entire
[email protected] www.rezayat-commerci cost shall be borne by manufacturer. Fresh Type
Contact Person Email ID - al.com Test was confirmed by manufacturer through
[email protected] their Letter # SEC/SECURE/PQL/PR/BEJ-1006-02
Website - www.securemeters.com dated 05.March.2021.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for Revenue Meters in
respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # SEC/SECURE/PQL/PR/BEJ-1005-02
dated 17.October.2021.

14. 5 Page 410 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ADVANCE ELECTRONICS CO., LTD. Type: USM-1 Type tests were PQ Letter
Saudi Arabia conducted in NMI Based on S&SD letter#19-00093-1-30504401
laboratory – dated January 27, 2019, the manufacturer is
Riyadh , Saudi Arabia Netherland prequalified for Revenue Meter as confirming to
30/04-11/05,2018 SEC specification #40-TMSS-03 Rev.01, with the
[email protected] and 19-22/11,2018. following conditions:
+966 11 220 1350 EX. 2357
WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #Nil dated
January 09, 2019.

LANDIS + GYR AG-ZUG Revenue Meters Type E650 (ZXD) & PQ Letter
SWITZERLAND E850 (ZXQ) Based on S&SD Letter 14-04075-30504401 dated
July 01, 2014, it is pre-qualified for Revenue
Landis+Gyr Ag Zug/Switzerland Meters Type E650 (ZXD) & E850 (ZXQ)
Theilerstr. 1 63O1 Zug,Switzerland. conforming to National Grid SA specifications #
Zug , Switzerland 40-TMSS-03, and 40-TMSS-02 with the following
conditions:
Contact Person - Mr. Akhlak
Husain,Area Manager. WARRANTY
Phone - +971 558854159 Ten (10) years extended warranty from the date
Email ID - [email protected] of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
by the manufacturer through their letter # Nil,
dated January 30, 2014.

E650 (ZXD) & E850 (ZXQ) [This meters are


approved for Revenue Meter application only].

Software for both meters [(E650 (ZXD) & E850


(ZXQ)] shall be MAP120 and MAP110 .

14. 5 Page 411 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LANDIS + GYR AG SAUDI MASAR E650-ZMD402CT44.0459 S3 Landis + Gyr AG - PQ letter:


Greece HIGH-TECH & Software for E650 meter are MAP120 Greece Based on S&SD letter # 17-04020-1-30504401
MARKETING CO. and MAP110 . successfully dated May 16, 2017, Landis + Gyr AG- Greece is
Plant -Greece P.O Box 990, Jeddah conducted type pre-qualified for Revenue Meters (type
21421, KSA tests on Revenue E650-ZMD402CT44.0459 S3) as conforming to
78km National Road Athens-Corinth, P. +966 Meters (type National Grid SA specification # 40-TMSS-03
O Box 207 GR- 201 00 Corinth, Greece 920005711/6133099 E650-ZMD402CT44. Rev.01, with the following conditions:
[email protected] 0459 S3) in
Contact Person - Mr. Akhlak Husain m.sa independent test
Phone - +971 4 452 66 26 laboratory (Quinel & WARRANTY:
Email ID - Metas) in the •Ten (10) years extended warranty from the date
[email protected] presence of two (2) of PAC of the project (in case of contract award)
Contact Person Email ID - SEC/National Grid or date of delivery (in case of direct material
[email protected] SA Engineers & supply order), as confirmed, through their Letter
Website - www.landisgyr.com Third Party inspector No. NIL dated May 11, 2016 shall be applicable for
(test report copy all Revenue Meters (type
enclosed). E650-ZMD402CT44.0459 S3) to be supplied to
SEC/National Grid SA.

ALPS TECHNOLOGIES PQ Lettter


FRANCE Based on TS&SD letter# 09-F00181/03-03032301
dated 06th. April 2009.
Annecy-Le-Vieux, France
WARRANTY
Five (5) years extended warranty from the date
of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order, as confirmed by the
manufacturer through their letter no.nil, dt: 10th
Feb, 2009.

ELSTER A1884RALNC meters with PQ Lettter


United States configuration ZE3KM4C4FLP-01 [ This Based on S&SD Letter 12-00932-1-30504401
Meter is approved for Revenue Meter dated March 25, 2012, it is pre-qualified for c as
Application only ]. confirming to SEC Specification # 40-TMSS-03,
with the following conditions:

WARRANTY
Five (5) years extended warranty from the date
of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order as confirmed through
ELSTER letter # NIL dated 12-01-2012.

14. 5 Page 412 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 7

METERS
14. 6
POWER QUALITY METER Applicable Standards: 40-TMSS-03

SEL Power Quality Meters Type (SEL-734) Yes PQ Letter


United States & SEL 734P Based on approval of Executive Directive for
TS&SD Letter # 08-1105-03032301 dated
Website - 20/10/2008, to AEC, Riyadh for the
http://www.selindustrial.com/ pre-qualification of AMR, Power Quality Meters
Type (SEL-734) & SEL 734P is pre-qualified as
per 40-TMSS-03,

14. 6 Page 413 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELECTRO INDUSTRIES / GAUGETECH Power Quality Meters type NEXUS Yes PQ Letter
United States 1500 Based on S&SD Letter 13-00862/03-030504401
dated April 20, 2013, Electro Industries/
New York United States GaugeTech, New York, USA is pre-qualified for
Power Quality Meters type NEXUS 1500 as
conforming to National Grid SA specification #
40-TMSS-03, Rev.0, with the following
conditions:

CONDITION:
Product Support: Continuous supply and product
support of Power Quality Meters type NEXUS
1500 to all SEC/ National Grid SA approved AMR
Manufacturers for a minimum period of ten (10)
years shall be ensured as confirmed through
their letter # Nil dated January 01, 2012.

Product Demo: EIG Tech USA in coordination with


their Local Agent (Ideal Technical Solutions,
Riyadh) shall demonstrate the hardware and
software capability and the features of NEXUS
1500 Power Quality Meters during the proposed
Live Demo of the AMR system to be conducted
on the first order in presence of SEC/National
Grid SA Engineers as already confirmed through
item # 8 of ITS letter # L1-NG01-J13-006 dated
February06, 2013.

WARRANTY:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or from the date of first delivery
of direct material supply order as confirmed by
Electro Industries /Gauge Tech -New York, USA
through their letter # L1-NG01-J13-004 dated
January 29, 2013.

Total = 2

PROTECTIVE RELAYS
15. 1
380 KV and Below Applicable Standards: 41-TMSS-01

15. 1 Page 414 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE Relay Type: L90


CANADA
Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
4CT+4VT+12BI’S+12BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS

L90-

Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF

74DC supply supervision


74 trip relay Coil Supervision

CT Supervision
60 VT Supervision
DFR/SOE /F locator

15. 1 Page 415 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hardware:
4CT+4VT+12BI’S+12BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS

L90-

Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS

Relay Type:
L90

L90-
CH2 to be attenuated to fit SDH

Function:
87L(Dual Combined Slope)

21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem

15. 1 Page 416 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

79(2CBs OR 1CB controlled)+25


50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS

L90

Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision

Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports

L90

Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision

15. 1 Page 417 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

50/51+50N/51N
Current Circuit Supervision

Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports

15. 1 Page 418 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Relay Type: Mfr. Name change from ABB Sweden AB to
SWEDEN Hitachi Energy Ltd. Hitachi Energy Sweden AB
Riyadh, Saudi Arabia RED670*1.2
Plant -Natverksgatan 3 Bnr 391: 721 36 Phone: +966 11 2181703
Vaesteras Mobile: +966 500414555 Function:
paulus.ralhana@hitachie 87L(Dual Combined Slope)
Contact Person - Mr. Paulus Ralhana nergy.com 21P&G(5 Zones,Quad+Mho+Bi)
(manager) 67DEF with comm. Schem
Email ID - 79(2CBs OR 1CB controlled)+25
[email protected] 50/51PH&GR/SEF/46
Contact Person Email ID - 67P/67N
[email protected] 49 Thermal overload
Website - www.hitachienergy.com 27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
4CT+4VT+12BI’s+12BO’s
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS

RED670*1.2

Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision

15. 1 Page 419 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DFR/SOE /F locator

Hardware:
4CT+4VT+12BI’s+12BO’s
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS

Relay Type:

RED670*1.2

Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF

74DC supply supervision


74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS

Relay Type:

RED670*1.2

Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25

15. 1 Page 420 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS

Type RET 670*1.2

Function:
87T (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE

Hardware:
2-WINDING:
14xCT(Ph)+4xCT(Gnd)
3-WINDING:
16xcontact inputs

15. 1 Page 421 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

8xcontact outputs
IEC 61850 2-ports

RET670*1.2-

Function:
87T (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)

87/50 Instan Diff


50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE

Hardware:
3-WINDING:
14xCT(Ph)+4xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports

REB500 CU

Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
CT Supervision
Intertrip facility
Selective Zone tripping and blocking

15. 1 Page 422 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HMI
DFR/SOE

Hardware:
CU: 8BI’s+8BO’s
24 PU connected to CU
IEC 61850, 2-PORTS

REB500

Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
CT Supervision
Intertrip facility
Selective Zone tripping and blocking
HMI
DFR/SOE

Hardware:
CU: 8BI’s+8BO’s
48 PU connected to CU
IEC 61850, 2-PORTS

:
REB500 PU

FP1-PD0-DR0-L0-T0+1MRB150073R00
52

Function:
50BF: stage1
50BF: stage2
End fault protection with Interntrip or
Dead Zone
HMI
DFR/SOE

Hardware:

15. 1 Page 423 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PU: 4CT+16BI’S+12BO’S

REC670

Functions:
27P
50/51 P&G
Undercurrent
50 2
59B&59N
59 2
Harmonic Overload
60P&N
87V phase&neutral
67 P&G
67 2
60 VT Supervision
DFR/SOE

Hardware:
6CT+6VT+16BI’s+24BO’s
IEC 61850,2-PORTS

RED670*1.2
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT+6VT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 850nm, CH-2 850nm (up to 3km)
IEC 61850 -2 Ports
Relay Type:
RED670

15. 1 Page 424 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RED670*1.2
-XE
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT+6VT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1310nm, CH-2 1310nm (up to
80km)
IEC 61850 -2 Ports

REC670

Function:
87 3-Phase High Z Differential
(based on Voltage)
50/51N
Internal CT Bus Wire Supervision
(based on voltage )
74TC Trip circuit Supervision
External Stabilizing
Resistor
External Metrosil
External CT Shorting

Hardware:
6I+6U
24BO
16BI
IEC 61850,2-Optical Ports (PRP)
REB650

Function:
87 3-Phase High Z Differential

15. 1 Page 425 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

(based on Voltage)
50/51N
Internal CT Bus Wire Supervision
(based on voltage )
74TC Trip circuit Supervision
External Stabilizing Resistor
External Metrosil
External CT Shorting

Hardware:
6I+4U
27BO

18BI
IEC 61850,2-Optical Ports (PRP)

REL670*1.2

Function:
Control & MIMIC
21 P&GD
50N/51 P&G
67P/67N
49 Thermal Overload
Phase unbalance 46
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

Hardware:
16 BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC

Other Type:

15. 1 Page 426 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

REQ 650
50/51/50N/51N/50BF/50BF/87 High

Machinefabrik Reinhausen GmbH (MR) 1- TAPCON 260 At TUV SUD - PQ Letter:


GERMANY AVC Germany and Based on S&SD letter # 20-01402-30504401
DNV.GL - dated July 26, 2020, Maschinenfabrik Reinhausen
Plant -Regensburg 2- TAPCON (Rating up to 380kV) Netherlands GmbH (MR), Germany is pre-qualified for
(Type Tests Ref. # Automatic Voltage Regulator Type TAPCON as
Falkensteinstrasse 8 TR-69469-72763-01 conforming to National Grid SA specification #
93059 Regensburg dated December 41-TMSS-01 with the following conditions:
2019 /
Contact Person - Onur Tufekci TR-69469-72591-01 WARRANTY:
Phone - +49 941 40909678 dated June 2020 / Ten (10) years extended warranty in respect of
Email ID - [email protected] Tests as per IEC the defects due to design, manufacturing,
Contact Person Email ID - 60255-5 & IEC installation and workmanship from the date of the
[email protected] 60255-27 with Ref. Provisional Acceptance Certificate (PAC) of the
Website - www.reinhausen.com # NIL dated June first turnkey project (in case of contract award)
2020 / 20-2457 & and from the date of first delivery in case of
20-2459 dated May direct material supply order shall be provided as
2020) confirmed by the manufacturer through their
letter # 201611_SEC
TAPCON_Extended/Warranty dated November
16, 2016.

15. 1 Page 427 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SEL Sel Khobar Type/Model - 411L


United States Contact Person: Omar
Yosef,PO Box 32191 Function:
Website - Khobar 31952 Line Differntial
http://www.selindustrial.com/ www.selinc.com 21P&G(5 Zones,Quad+Mho+Bi)
Email - omar 67DEF with comm. Schem
[email protected] 79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
27/59/59
50BF
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS

0411L

Function:
87L
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
27/59/59N
50BF
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS

15. 1 Page 428 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Type/Model - 487V
Rating - 380/132/115/110/69/33/13.8kV

Functions:
27P
50/51 P&G
Undercurrent
50 2
59B&59N
59 2
Harmonic Overload
60P&N
87V phase&neutral
67 P&G
67 2
60 VT Supervision
DFR/SOE

Hardware:
6CT+6VT+15BI’s+23BO’s
IEC 61850,2-PORTS

SEL411L

Function:
Line diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision

Hardware:
Analog Inputs (6CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports

15. 1 Page 429 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

0411L

Function:
Line diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision

Hardware:
Analog Inputs (6CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports

15. 1 Page 430 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

UK Grid Solutions Ltd-UK Relay Type:


United Kingdom MiCOM P546

United Kingdom Function:


87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
4CT+4VT+12BI’s+12BO’s
8CT+4VT+16BI’s+16BO’s
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS

P546

Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N

49 Thermal overload
27/59/59N
50BF

74DC supply supervision


74 trip relay Coil Supervision

15. 1 Page 431 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CT Supervision
60 VT Supervision
DFR/SOE /F locator

Hardware:
4CT+4VT+12BI’s+12BO’s
8CT+4VT+16BI’s+16BO’s
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS

Micom P643

Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instantaneous Diff
50/51PH&GR all windings
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC Supply Supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE

Hardware:
2-WINDING:
9xCT (Ph) + 4xCT (Gnd)
3-WINDING:
16xcontact inputs
8xcontact outputs
IEC 61850 2-ports

P645

Functions:

15. 1 Page 432 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

87L (dual combined slope)


87 REF (low impedance)
87 REF (High impedance)
87/50 Instantaneous Diff
50/51PH&GR all windings
67P/67N(All windings)

27/59/25
81 U/O
50 BF
49T
24
74 DC Supply Supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE

Hardware:
3-WINDING:
15xCT(Ph)+3xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports

MICOM P740 PU
P741
Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage2
CT Supervision
Intertrip facility
Selective Zone tripping and blocking
HMI
DFR/SOE

Hardware:
CU: 8BI’S+8BO’S
24 PU connected to CU
IEC 61850, 2-PORTS

15. 1 Page 433 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MICOM P740
P743
Function:
50BF: stage1
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
HMI
DFR/SOE

Hardware:
PU: 4CT+16BI’s+12BO’S
IEC 61850, 2-PORTS

MiCOM P543

Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision

Hardware:
Analog Inputs (5CT+4VT)
Binary Inputs – 16 Inputs
Binary Outputs 14
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports

P5433
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N

15. 1 Page 434 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Current Circuit Supervision

Hardware:
Analog Inputs (5CT+4VT)
Binary Inputs – 16 Inputs
Binary Outputs 14
CH-1 1300nm, CH-2 1300nm (up to
50km)
IEC 61850 -2 Ports

MCAG34

Function:
87 3-Phase High Z Differential (Current
Base)
External CT Bus Wire Supervision
External stabilizing Resistor
External Metrosil
External CT Shorting

Hardware:
3 CT Inputs
2 Output Contacts

Ordering code:
MCAG14SSD**** *A
Built in Function:
87 3-Phase High Z Differential
(Current Base)
External CT Bus Wire Supervision
External Stabilizing Resistor
External Metrosil
External CT Shorting

Hardware:
1 CT Phase Inputs
2 Output Contacts

MFAC

15. 1 Page 435 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Built in Function:
87 3-Phase High Z Differential.
(Based on Voltage)
External CT Bus Wire Supervision
Internal Stabilizing Resistor
External Metrosil
External CT Shorting

Hardware:
1 elements / phases voltage based
4 Output Contacts

Other Type:
MICOM P142
87 3-Phase High Z
50BF
Differential, 50/51N, CT Bus-wire
Supervision (95), TCS : Trip Circuit
Supervision, 74 DC supply supervision
27/59/59N,
Breaker Failure (50BF) 74DC DC
SUPPLY SUPERVISION, 67P/67N,
Under / Over
Frequency 81, Under current 37, 60VT
Supervision, DFR
/SOE/F Locator

MICOM P143
25

MICOM P443
Distance/85

MICOM P841
25/79

15. 1 Page 436 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB REF615 PQ Letter


FINLAND Function: Based on S&SD letter # 16-10663-030504401
Control & MIMIC dated January 09,2017, ABB - Finland is
50N/51 P&GD pre-qualified for PROTECTIVE RELAYS System
67P/67N as conforming to National Grid SA specification #
49 Thermal Overload 41-TMSS-01, with the following conditions:
Phase Unbalance 46
27/59 WARRANTY:
Auto reclosure 79 Ten (10) years extended warranty from the date
50BF of PAC of the first turnkey project (in case of
Trip circuit Supervision 74TC contract award) or date of first delivery (in case
Inrush Blocking of direct material supply order), as confirmed,
Under/Over frequency 81 through their Letter No. NIL dated 06/03/2014
CT Supervision shall be applicable for the ABB-Finland.
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
16BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC

- REF620

REF620

Function:
Multi-stage overcurrent and earth fault
50/51, 50N/51N
Undercurrent 37
Over and under voltage 59/27
synchrocheck 25
over and under frequency 81
Auto-reclose 79
CT and VT supervision 60
Trip circuit supervision 74TC
Circuit breaker failure 50CBF
High impedance bus bar protection,
External Stabilizing Resistor
External Metrosil
External CT Shorting
IEC 61850 Ed.2 with PRP

15. 1 Page 437 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SCHNEIDER ELECTRIC Schneider Electric EPS Type/Model - 8 Models of MICOM Test Date - April Old Comments:
United Kingdom Ltd P546 2014 PQ Letter
PO Box 89249 Riyadh Based on S&SD letter # 14-040883-2-30504401
Plant -United Kingdom-Stone 11682 Saudi Arabia Functions: 87L, Under current dated June 12, 2014, M/s Schneider Electric from
Phone - 37,Inrush Blocking, Under / over United Kingdom – stone is prequalified for MiCOM
Schneider Electric Energy Ltd Unit 9 +966-11-291-28-77 x Frequency 81,open conductor P546 as per the following conditions:
Opal Way Stone Business Park Stone 360 protection, Second harmonic detection,
St15 0Ss United Kingdom Stone , United Email - 21P&G, 67DEF, 79 (1 CB or 2 CB) CONDITION:
Kingdom padma.raja@schneider- controlled + 25, SEF, 50/51PH&GR / Type tests shall be carried out on the MiCOM
electric.com SEF/46, 67P/ 67N ,49 Thermal P546 relays as per new IEC 61850-10 (2012-12)
Contact Person - Mr. Paul Kerr Overload, 27/59/59N, 50BF, 74 DC edition 2 in the approved Independent Testing
Phone - +44 7917 534038 supply supervision, 74 Trip circuit laboratory witnessing by three (3) National Grid
Email ID - supervision, CT Supervision, 60 VT SA engineers and one (1) approved Independent
[email protected] Supervision, DFR/SOE / Fault Locator Agency Inspector (IIA). All costs of witnessing
Website - Hardware: 8xCT(Ph) + 5xVT, 32 Digital the tests shall be borne by the manufacturer as
http://www.schneider-electric.com Inputs, 24Digital Outputs, Protection per their confirmation through letter # Nil dated
data interface-1 850, October 23, 2013.
Protection data interface-2 850,
IEC61850, 2 x WARRANTY:
Ten (10) years extended warranty/guarantee in
port(PRP) respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Functions: 87L, Under current first turnkey project in case of contract award or
37,Inrush Blocking, Under / over date of delivery in case of direct material supply
Frequency 81,open conductor order.
protection, Second harmonic detection,
21P&G, 67DEF, 79 (1 CB or 2 CB) PQ Letter
controlled + 25, SEF, 50/51PH&GR / Based on S&SD letter # 14-040883-2-30504401
SEF/46, 67P/ 67N ,49 Thermal dated June 12, 2014, M/s Schneider Electric from
Overload, 27/59/59N, 50BF, 74 DC United Kingdom – stone is prequalified for MiCOM
supply supervision, 74 Trip circuit P543 as per the following conditions:
supervision, CT Supervision, 60 VT
Supervision, DFR/SOE / Fault Locator CONDITION:
Hardware: 8xCT(Ph) + 5xVT, 32 Digital Type tests shall be carried out on the MiCOM
Inputs, 24Digital Outputs, Protection P543 relays as per new IEC 61850-10 (2012-12)
data interface-1 1300, Protection data edition 2 in the approved Independent Testing
interface-2 850, IEC61850, 2 x laboratory witnessing by three (3) National Grid
port(PRP) SA engineers and one (1) approved Independent
Agency Inspector (IIA). All costs of witnessing
the tests shall be borne by the manufacturer as
Functions: 87L, Under current per their confirmation through letter # Nil dated

15. 1 Page 438 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

37,Inrush Blocking, Under / over October 23, 2013.


Frequency 81,open conductor
protection, Second harmonic detection, WARRANTY:
21P&G, 67DEF, 79 (1 CB or 2 CB) Ten (10) years extended warranty/guarantee in
controlled + 25, SEF, 50/51PH&GR / respect of defects due to design, manufacture,
SEF/46, 67P/ 67N ,49 Thermal installation & workmanship from the date of
Overload, 27/59/59N, 50BF, 74 DC Provisional Acceptance Certificate (PAC) of the
supply supervision, 74 Trip circuit first turnkey project in case of contract award or
supervision, CT Supervision, 60 VT date of delivery in case of direct material supply
Supervision, DFR/SOE / Fault Locator order.
Hardware: 8xCT(Ph) + 5xVT, 32 Digital
Inputs, 24Digital Outputs, Protection
data interface-1 1550, Protection data PQ Letter
interface-2 850, IEC61850, 2 x port Based on S&SD letter # 14-040883-2-30504401
(PRP) dated June 12, 2014, M/s Schneider Electric from
United Kingdom – stone is prequalified for MiCOM
P142 as per the following conditions:
Type/Model - 8 Models of MICOM : P543
CONDITION:
Functions: 87L(Dual Combined Slope), Type tests shall be carried out on the MiCOM
21P&G (5Zones,Quad+Mho+Bi), 67DEF P142 relays as per new IEC 61850-10 (2012-12)
with comm. Scheme, 79(2CBs OR 1CB edition 2 in the approved Independent Testing
controlled)+25, 50/51PH&GR / SEF/46, laboratory witnessing by three (3) National Grid
67P/ 67N, 49 Thermal Overload, SA engineers and one (1) approved Independent
27/59/59N, 50BF, 74 DC supply Agency Inspector (IIA). All costs of witnessing
supervision, 74 Trip circuit supervision, the tests shall be borne by the manufacturer as
CT Supervision, 60 VT Supervision, per their confirmation through letter # Nil dated
DFR/SOE / Fault Locator, October 23, 2013.
Hardware: 4CT+4VT+ 12BI's+12BO's,
CH-1 1300nm, CH-2 850nm, IEC61850, WARRANTY:
2 x port(PRP) Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
P543 installation & workmanship from the date of
Functions: 87L, Under current Provisional Acceptance Certificate (PAC) of the
37,Inrush Blocking, Under / over first turnkey project in case of contract award or
Frequency 81,open conductor date of delivery in case of direct material supply
protection, Second harmonic detection, order.
21P&G, 67DEF, 79 (1 CB or 2 CB)
controlled + 25, SEF, 50/51PH&GR /
SEF/46, 67P/ 67N ,49 Thermal PQ Letter
Overload, 27/59/59N, 50BF, 74 DC Based on S&SD letter # 14-040883-2-30504401
supply supervision, 74 Trip circuit dated June 12, 2014, M/s Schneider Electric from

15. 1 Page 439 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

supervision, CT Supervision, 60 VT United Kingdom – stone is prequalified for MiCOM


Supervision, DFR/SOE / Fault Locator P841 as per the following conditions:
Hardware: 4CT+4VT+ 12BI's+12BO's,
CH-1 1550nm, CH-2 850nm, IEC61850, CONDITION:
2 x port(PRP) Type tests shall be carried out on the MiCOM
P841 relays as per new IEC 61850-10 (2012-12)
edition 2 in the approved Independent Testing
Models of MICOM : P142 laboratory witnessing by three (3) National Grid
SA engineers and one (1) approved Independent
Functions: 87L High Impedance, 95 CT Agency Inspector (IIA). All costs of witnessing
bus wire supervision, 50/51PH&GR / the tests shall be borne by the manufacturer as
SEF/46, 67P/ 67N , SEF,49 Thermal per their confirmation through letter # Nil dated
Overload, 27/59/59N, 50BF, 74 DC October 23, 2013.
supply supervision, 74 Trip circuit
supervision, CT Supervision, 60 VT WARRANTY:
Supervision, DFR/SOE / Fault Locator Ten (10) years extended warranty/guarantee in
Hardware: 5xCT(Ph) + 3xVT, 16 Digital respect of defects due to design, manufacture,
Inputs, 7Digital Outputs, IEC61850, 2 x installation & workmanship from the date of
port(PRP) Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Ordering Code: P14231NC7M0468J date of delivery in case of direct material supply
Functions: 50/51PH&GR / SEF/46, 67P/ order.
67N , SEF,49 Thermal Overload,
27/59/59N, 50BF, 74 DC supply
supervision, 74 Trip circuit supervision, Old Comments:
CT Supervision, 60 VT Supervision, PQ Letter
DFR/SOE / Fault Locator Based on S&SD letter # 14-040883-2-30504401
Hardware: 5xCT(Ph) + 3xVT, 16 Digital dated June 12, 2014, M/s Schneider Electric from
Inputs, 7Digital Outputs, IEC61850, 2 x United Kingdom – stone is prequalified for MiCOM
port(PRP) P643 + MiCOM P849 as per the following
conditions:

Models of MICOM : P841 CONDITION:


Type tests shall be carried out on the MiCOM
Functions: 79 (1 CB or 2 CB) P643 + MiCOM P849 relays as per new IEC
controlled + 25, 50/51PH&GR / SEF/46, 61850-10 (2012-12) edition 2 in the approved
67P/ 67N , SEF,49 Thermal Overload, Independent Testing laboratory witnessing by
27/59/59N, 50BF, 74 DC supply three (3) National Grid SA engineers and one (1)
supervision, 74 Trip circuit supervision, approved Independent Agency Inspector (IIA). All
CT Supervision, 60 VT Supervision, costs of witnessing the tests shall be borne by
DFR/SOE / Fault Locator the manufacturer as per their confirmation
Hardware: 8xCT(Ph) + 5xVT, 24 Digital through letter # Nil dated October 23, 2013.

15. 1 Page 440 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Inputs, 32Digital Outputs, IEC61850, 2 x


port(PRP) WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Type/Model - 9 Models of MICOM P643 installation & workmanship from the date of
+ MiCOM P849 Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Functions: 87T ( Dual Combined Slope), date of delivery in case of direct material supply
87REF (low Impedance), 87REF (High order.
Impedance), 87/50 Instantaneous Diff,
50/51PH&GR All Windings, 67P/67N (All
Windings), 27/59/25, 81U/O, 50BF, 49T, PQ Letter
24, 74 DC supply supervision, 74 Trip Based on S&SD letter # 14-040883-2-30504401
circuit supervision, CT Super. (All dated June 12, 2014, M/s Schneider Electric from
Windings), 60 VT Supervision, United Kingdom – stone is prequalified for MiCOM
DFR/SOE, P642 + MiCOM P849 as per the following
Hardware: 15xCT(Ph) + 3xCT(Gnd) + conditions:
4xVT, 32+16 Digital Inputs, 16+16
Digital Outputs, IEC61850, 2 x port CONDITION:
(PRP) Type tests shall be carried out on the MiCOM
P642 + MiCOM P849 relays as per new IEC
61850-10 (2012-12) edition 2 in the approved
Functions: 87T ( Dual Combined Independent Testing laboratory witnessing by
Slope), 50/51PH&GR/SEF/46, 67P/67N, three (3) National Grid SA engineers and one (1)
49Therma l overload, 27/59/81/59N, approved Independent Agency Inspector (IIA). All
50BF74 DC supply supervision, CT costs of witnessing the tests shall be borne by
Supervision, 60 VT Supervision, the manufacturer as per their confirmation
DFR/SOE through letter # Nil dated October 23, 2013.
Hardware: 9xCT(Ph) + 3xCT(G) +
4xVT , 16+64 Digital Inputs, 16+16 WARRANTY:
Digital Outputs, IEC61850, 2 x port Ten (10) years extended warranty/guarantee in
(PRP) respect of defects due to design, manufacture,
installation & workmanship from the date of
MiCOM P642 – MiCOM P849 Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Functions: 87T ( Dual Combined Slope), date of delivery in case of direct material supply
87REF (low Impedance), 87REF (High order.
Impedance), 87/50 Instantaneous Diff,
50/51PH&GR All Windings, 67P/67N (All
Windings), 27/59/25, 81U/O, 50BF, 49T, PQ Letter
24, 74 DC supply supervision, 74 Trip Based on S&SD letter # 14-040883-2-30504401
circuit supervision, CT Super. (All dated June 12, 2014, M/s Schneider Electric from

15. 1 Page 441 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Windings), 60 VT Supervision, United Kingdom – stone is prequalified for MiCOM


DFR/SOE, 142 + MiCOM P849 as per the following
Hardware: 9xCT(Ph) + 3xCT(Gnd) + conditions:
4xVT, 32+12
CONDITION:
Digital Inputs, 16+12 Digital Outputs, Type tests shall be carried out on the MiCOM 142
IEC61850, 2 x port (PRP) + MiCOM P849 relays as per new IEC 61850-10
(2012-12) edition 2 in the approved Independent
MiCOM P142 + P849 Testing laboratory witnessing by three (3)
National Grid SA engineers and one (1) approved
Functions: 87 High Impedance Diff Independent Agency Inspector (IIA). All costs of
Protection, SEF, 50/51+50N/51N / 46, witnessing the tests shall be borne by the
49 Thermal Overload, 27/59/59N, manufacturer as per their confirmation through
Breaker Failure (50BF) 74DC DC letter # Nil dated October 23, 2013.
SUPPLY SUPERVISION, CT
Supervision, 67P/67N, Under / Over WARRANTY:
Frequency 81, Under current 37, 60VT Ten (10) years extended warranty/guarantee in
Supervision, DFR/SOE/F Locator respect of defects due to design, manufacture,
Hardware: 5xCT(Ph) + 3xVT 16+64 installation & workmanship from the date of
Digital Inputs, 7+16 Digital Outputs, Provisional Acceptance Certificate (PAC) of the
IEC61850, 2 x port (PRP) first turnkey project in case of contract award or
date of delivery in case of direct material supply
P142 order.
Functions: 87 High Impedance Diff
Protection, SEF, 50/51+50N/51N / 46,
49 Thermal Overload, 27/59/59N, PQ Letter
Breaker Failure (50BF) 74DC DC Based on S&SD letter # 14-040883-2-30504401
SUPPLY SUPERVISION, CT dated June 12, 2014, M/s Schneider Electric from
Supervision, 67P/67N, Under / Over United Kingdom – stone is prequalified for MiCOM
Frequency 81, Under current 37, 60VT P543 as per the following conditions:
Supervision, DFR
/SOE/F Locator CONDITION:
Type tests shall be carried out on the MiCOM P40
Hardware: 5xCT(Ph) + 3xVT , 16 Digital relays as per new IEC 61850-10 (2012-12)
Inputs, 7 Digital Outputs IEC61850, 2 x edition 2 in the approved Independent Testing
port (PRP) laboratory witnessing by three (3) National Grid
SA engineers and one (1) approved Independent
Agency Inspector (IIA). All costs of witnessing
Type/Model - MICOM P543 , the tests shall be borne by the manufacturer as
per their confirmation through letter # Nil dated
Functions: 21 P&GD / 87 L, October 23, 2013.
50/51PH&GR, 67P/ 67N, 49 Thermal

15. 1 Page 442 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Overload, Phase Unbalance 46, Under WARRANTY:


current 37, 27/59, Auto Re-closure 79, Ten (10) years extended warranty/guarantee in
50BF, 74 Trip circuit supervision, In respect of defects due to design, manufacture,
rush blocking, Under/over Frequency installation & workmanship from the date of
81, CT Supervision, 60 VT Supervision, Provisional Acceptance Certificate (PAC) of the
Open conductor protection, second first turnkey project in case of contract award or
harmonic detection, sensitive earth date of delivery in case of direct material supply
fault protection, DFR/SOE / Fault order.
Locator.
Hardware: 5CT + 4VT, 16BI+14BO,
IEC61850, 2 x optical port (PRP) PQ Letter
Based on S&SD letter # 14-040883-2-30504401
dated June 12, 2014, M/s Schneider Electric from
Type/Model - Three model of MICOM, United Kingdom – stone is prequalified for MiCOM
,MICOM P543, MiCOM P142 P142 as per the following conditions:

Functions: Cable Diff. Protection, CONDITION:


Breaker Failure (50BF), DC supply Type tests shall be carried out on the MiCOM P40
supervision, 50/51 + 50N/51N, Current relays as per new IEC 61850-10 (2012-12)
Circuit Supervision,. edition 2 in the approved Independent Testing
Hardware: 5 Analog Inputs CT, 4 laboratory witnessing by three (3) National Grid
Analog input VT, 16 Binary Inputs-14 SA engineers and one (1) approved Independent
outputs, CH-1 820nm, CH-2 820nm (up Agency Inspector (IIA). All costs of witnessing
to 1KM), IEC61850, 2 x port (PRP), the tests shall be borne by the manufacturer as
P5433 per their confirmation through letter # Nil dated
Functions: Cable Diff. Protection, October 23, 2013.
Breaker Failure (50BF), DC supply
supervision, 50/51 + 50N/51N, Current WARRANTY:
Circuit Supervision. Ten (10) years extended warranty/guarantee in
Hardware: 5 Analog Inputs CT, 4 respect of defects due to design, manufacture,
Analog input VT, 16 installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Binary inputs-14 outputs, CH-1 1300nm date of delivery in case of direct material supply
,CH-2 1300nm (up to 50KM), IEC61850, order.
2 x port (PRP),
MICOM P142
PQ Letter
Functions: High Impedance Diff Based on S&SD letter # 14-040883-2-30504401
Protection, Internal CT Bus-wire dated June 12, 2014, M/s Schneider Electric from
Supervision (95) , Breaker Failure United Kingdom – stone is prequalified for MiCOM
(50BF), DC Supply Supervision, P643 as per the following conditions:

15. 1 Page 443 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

50/51+50N/51N, Current Circuit


Supervision CONDITION:
Hardware: 5CT + 3 VT, 16 BI, 7 BO, Type tests shall be carried out on the MiCOM
IEC61850, (? 300m and GIB), 2 x port P643 relays as per new IEC 61850-10 (2012-12)
IEC61850 (PRP) edition 2 in the approved Independent Testing
laboratory witnessing by three (3) National Grid
Rating - for all voltage SA engineers and one (1) approved Independent
Agency Inspector (IIA). All costs of witnessing
the tests shall be borne by the manufacturer as
Type/Model - MICOM P142 per their confirmation through letter # Nil dated
Functions: 87 3-Phase High Z October 23, 2013.
Differential, 50/51N, CT Bus-wire
Supervision (95), TCS : Trip Circuit WARRANTY:
Supervision, 74 DC supply supervision, Ten (10) years extended warranty/guarantee in
External stabilizing resistor, External respect of defects due to design, manufacture,
Metrosil Resistor, External CT shorting installation & workmanship from the date of
Hardware: 5CT + 3 VT, 16 BI, 5CT Provisional Acceptance Certificate (PAC) of the
Input+3 VT input, 8 BI, 11 BO, first turnkey project in case of contract award or
IEC61850, 2 optical ports (PRP) date of delivery in case of direct material supply
order.

Type/Model - MICOM P142


Functions: 67P/67N, 50 N / 51PH&GR,
SEF, 49 Thermal Overload, 27/59/59N,
50BF, 74DC DC\ circuit supervision, 74
Trip circuit supervision, CT
Supervision, VT Supervision, Stub
protection, DFR/SOE / Fault Locator
Hardware: 5CT + 3 VT, 16 BI, 7 BO,
IEC61850, 2 x port (PRP)

Type/Model - MICOM P142


Functions: 2 CB breaker Failure, CBF
reset by Under current, CBF reset by
CB status, Pole discrepancy, 50BF, 74
Trip circuit supervision,
50/51/67+50N/51N/67N+46, 27/59/59N,
Fuse Fail supervision, DFT/SOE
Hardware: 5xCT(Ph) + 3xVT, 16 Digital
Inputs, 7 Digital Outputs, IEC61850, 2
portx (PRP)

15. 1 Page 444 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Type/Model - MICOM P142


Functions: 87 High Impedance,
50/51PH&GR / SEF/46, 67P/ 67N, 49
Thermal Overload, 27/59/59N, 50BF, 74
DC supply supervision, 74 Trip circuit
supervision, CT Supervision, 60 VT
Supervision, DFR/SOE / Fault Locator
Hardware: 5xCT(Ph) + 3xVT, 16 Digital
Inputs, 7 Digital Outputs, IEC61850, 2 x
(PRP)

Type/Model - MICOM P643


Rating - 132-115-110 KV

Functions: 87T ( Dual Combined Slope),


87REF (low Impedance), 87REF (High
Impedance), 87REF , 87/50
Instantaneous Diff, 67P/67N (All
Windings), 50/51PH&GR All Windings, ,
27/59, 81U/O, 50BF, 49T, 24, 74 DC
supply supervision, 74 Trip circuit
supervision, CT Super. (All Windings),
60 VT Supervision, DFR/SOE,
Hardware: 9xCT(Ph) + 3xCT(Gnd) +
4xVT, 16 Digital Inputs, 16 Digital
Outputs, IEC61850, 2 x port (PRP)

Type/Model - MICOM P543

Functions: Open Conductor , Protection


for primary cables, Second harmonic
detection, under/ over frequency, In
rush blocking, Under & Over
Frequency 81, 87L,21 P&G, 67DEF, 79
+ 25 (1CB), ,50/51 P&G + 46, SEF,
67P/67N, 49 Thermal Overload,
27/59/59N, 50 BF, 74 Trip circuit
supervision, 74DC DC circuit

15. 1 Page 445 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

supervision, CT Supervision, 60 VT
Supervision, DFR/SOE / Fault Locator
Hardware: 5xCT(Ph) + 4xVT, 16 Digital
Inputs, 14 Digital Outputs, Protection
data interface-1 1300, Protection data
interface-2 1300, IEC61850, 2 x optical
port(fiber) (PRP)

Other Type:
MICOM P139
27/59/UVLS/UFLS

15. 1 Page 446 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS SIEMENS Ltd Saudi (SIPROTEC 4); (SIPROTEC 5): (SIPROTEC 5):
GERMANY Arabia Relay Type: Type test Report # Based on S&SD letter # 17-00825-30504401
Khaleel.al-adani@siemen 7SD522 G0M-1412-4383-S0 dated March 14, 2017, Siemens Berlin, Germany
Berlin, Germany s.com C000-V01 is pre-qualified for Protective Relays as
IC SG EA MF Local: Mr. Khaleel Dated: December conforming to National Grid SA specification #
Wernerwerkdamm 5, Al-Adani Function: 2014 41-TMSS-0,Rev.0, with the following conditions:
13629, Berlin, Germany Mob: +966 505892043 87L(Dual Combined Slope) Laboratory: •Ten (10) years extended warranty from the date
+966126618831 21P&G(5 Zones,Quad+Mho+Bi) Eurofins Product of PAC of the first turnkey project (in case of
Phone - +49 (911) 433 8321 Khaleel.al-adani@siemen 67DEF with comm. Schem Service GmbH contract award) or date of first delivery (in case
Website - s.com 79(2CBs OR 1CB controlled)+25 of direct material supply order), as confirmed,
www.siemens.com/ingenuityforlife 50/51PH&GR/SEF/46 & RTDS Test Report through their letter # EA PRO/Pz, dated April 22,
67P/67N # EM DG PTI PSC / 2014 shall be applicable for all protective relays
49 Thermal overload pc200768 / VH to be supplied to SEC/National Grid SA.
27/59/59N Dated December
50BF 2016
74DC supply supervision Laboratory: (SIPROTEC 5):
74 trip relay Coil Supervision Siemens Germany PQ Letter:
CT Supervision AG Based on S&SD letter # 17-00825-30504401
60 VT Supervision dated March 14, 2017, Siemens Berlin, Germany
DFR/SOE /F locator (FOR TYPE 7SA8X) is pre-qualified for (SIPROTEC 5) as conforming
Type Tests to National Grid SA specification # 41-TMSS-0
Hardware: successfully
4CT+4VT+12BI’S+12BO’S completed at WARRANTY:
CH-1 1300nm, CH-2 850nm EUROFINS, Ten (10) years extended warranty from the date
IEC 61850,2-PORTS AUCOTEAM and of PAC of the first turnkey project (in case of
PRO-EMV Germany contract award) or date of first delivery (in case
from 17th to 26th of direct material supply order), as confirmed,
7SD522 February 2016 Test through their letter # EA PRO/Pz, dated April 22,
report No. 2014 shall be applicable for all (SIPROTEC 5
Function: 11635316. Relays) to be supplied to SEC/National Grid SA.
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi) PQ Letter:
67DEF with comm. Schem Type Tests Based on S&SD letter # 17-00825-30504401
79(2CBs OR 1CB controlled)+25 successfully dated March 14, 2017, Siemens Berlin, Germany
50/51PH&GR/SEF/46 completed at ( is pre-qualified for (SIPROTEC 5) as conforming
67P/67N KEMA, Aucoteam to National Grid SA specification # 41-TMSS-0
49 Thermal overload and SIEMENS )
27/59/59N WARRANTY:
50BF Ten (10) years extended warranty from the date
74DC supply supervision of PAC of the first turnkey project (in case of
74 trip relay Coil Supervision contract award) or date of first delivery (in case
of direct material supply order), as confirmed,

15. 1 Page 447 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CT Supervision through their letter # EA PRO/Pz, dated April 22,


60 VT Supervision 2014 shall be applicable for all (SIPROTEC 5
DFR/SOE /F locator Relays) to be supplied to SEC/National Grid SA.

Hardware: (FOR 7SA8x)


4CT+4VT+12BI’S+12BO’S Based on S&SD letter #21-01088-030504401
CH-1 1550nm, CH-2 850nm dated September 29, 2021, Siemens Berlin,
IEC 61850,2-PORTS Germany is pre-qualified for (7SA8x Siprotec 5)
as conforming to National Grid SA specification #
41-TMSS-01
(SIPROTEC 5): WARRANTY:
Type 7SL87 Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
Functions: of direct material supply order), as confirmed,
87L Dual Combined Slop through their Letter Ref. Distance Protection
21P&G 7SA8x dated September 21, 2021 shall be
67DEF with Comm. Scheme applicable for the equipment to be supplied to
79+25 SEC/National Grid SA.
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator
1/3 POLE

Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1550nm (100km)
Protection Interface 2:820nm (1.5km)
IEC61850 -PRP x 2 FO ports

15. 1 Page 448 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Type 7SL86

functions :
87L Dual Combined Slop
21P&G
67DEF with Comm. Scheme
79+25
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator

Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1300nm (60km)
Protection Interface 2:820nm (1.5km)
IEC61850 -PRP x 2 FO ports

Type 7SL86
Ordering code:
7SL86-P1C40594

Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1550nm (100km)

15. 1 Page 449 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Protection Interface 2:820nm (1.5km)


IEC61850 -PRP x 2 FO ports

(SIPROTEC 4):
7UT6

Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
CT Super (All windings)
60
DFR/SOE

Hardware:
2-WINDING:
9xCT(Ph)+4xCT(Gnd)
3-WINDING:
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports

7UT6

Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)

87/50 Instan Diff


50/51PH&GR all windings.

15. 1 Page 450 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

67P/67N(All windings)

27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
CT Super (All windings)
60
DFR/SOE

Hardware:
3-WINDING:
12xCT(Ph)+4xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports

(SIPROTEC 5):
Type 7UT85

functions:
87T Dual combined slop
87REF low Impedance
87REF High Impedance
87/50 Instantaneous Diff
50/51PH&GR All Windings
67/67N All Windings
27/59/25
81U/O
50BF
49T
24
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT

15. 1 Page 451 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DFR/SOE

Hardware:
9 PH CT + 3 GND CT
4 VT
21 BI
28 BO
IEC61850 -PRP x 2 FO ports

7SS52x CU
Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage1
50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
Selective Zone tripping and blocking
HMI
DFR/SOE

Hardware:
CU: 8BI’s+8BO’s
24 PU connected to CU
IEC 61850, 2-PORTS

Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage1
50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone

15. 1 Page 452 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Selective Zone tripping and blocking


HMI
DFR/SOE
Hardware:
CU: 8BI’s+8BO’s
48 PU connected to CU
IEC 61850, 2-PORTS
7SS52x PU

7SS5231-

Built in Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage1
50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
Selective Zone tripping and blocking
HMI
DFR/SOE

Hardware:

PU: 4CT+16BI’s+12BO’S

(SIPROTEC 4):
7SA6x

Function:
Control & MIMIC
21 P&GD
50N/51 P&G
67N
49 Thermal Overload
27/59
Auto reclosure 79

15. 1 Page 453 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

Hardware:
16 BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC

(SIPROTEC 5):
Type 7SL86

functions:
87L Dual Combined Slop
21P&G
67DEF with Comm. Scheme
79+25
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator

Hardware:
3 PH CT+ 1 SENSITIVE GND CT
4 VT
23 BI
22BO
Protection Interface 1:1300nm (24km)
Protection Interface 2:1300nm (24km)

15. 1 Page 454 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

IEC61850 -PRP x 2 FO ports

(SIPROTEC 4):
7SJ64

Function:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

Hardware:
15BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC

7SD52

Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision

Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24

15. 1 Page 455 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CH-1 820nm, CH-2 820nm (up to 1.5km)


IEC 61850 -2 Ports

Ordering code:
7SD5221

Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision

Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports

7SJ64

Function:
87 3-Phase High Z Differential
(based on current)50/51N
Internal CT Bus Wire Supervision
(based on current )
74TC Trip circuit Supervision
External Stabilizing Resistor
External Metrosil
External CT Shorting

Hardware:
4 CT Inputs
13BO
15BI
IEC 61850, 2-Optical Ports (PRP)

Type 7VK87

15. 1 Page 456 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Functions:
Breaker Failure 50BF
Synch Check 25
79
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE

Hardware:
4 CT
4 VT
11 BI
09 BO
IEC61850 -PRP x 2 FO ports

Type 7SL86

Functions:
87L
21P&G
50/51 PH&GR
49
PHASE UNBALANCE
79
50BF
Inrush Blocking
81
Sensitive Earth element
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision

15. 1 Page 457 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

60VT
DFR/SOE/F locator

Hardware:
3 PH CT+ 1 SENSITIVE GND CT
4 VT
23 BI
22 BO
Protection Interface 1:1300nm (24km)
Protection Interface 2:1300nm (24km)
IEC61850 -PRP x 2 FO ports

Type 7SJ82
Ordering code:
7SJ82-P1J66121

Functions:
SEND / RECEIVE remote/local
COMMANDS
Supervision & Monitoring Functions:
CT supervision
74TC
74DC Supervision
74 Lockout Supervision
DFR/SOE

Hardware:
4 CT
11 BI
09 BO
Protection Interface 1:1550nm (100km)
Protection Interface 2:1550nm (100km)
IEC61850 -PRP x 2 FO ports

Other Type:
6MD61
I/O

7UT6
50/51

15. 1 Page 458 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

7RW80
27/59/UVLS/UFLS

7SA522
85

7VK61
25/79/50BF/27/59

TYPE 7SA8X
Function
21
21N
68
78
85
50/50N /51/51N
50BF
67/67N/79/25
81
27
59

7SJ80
SIPROTEC 4 Compact
(50/51/50BF/50N/51N/67/67N/87N/79/2
5/81/27/59)

TYPE 7SJ8x
Function:

50N/51 P&GD
High Impedance Protection
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC

15. 1 Page 459 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

ZIV ZIV OEM /Al-Fanar • Functions: 50,51, 50N, 51N, 50G, Type test was PQ Letter
SPAIN Exit 18 – Riyadh - Saudi 51G, 50Q, 51Q, 50Ns, 51Ns, 51Ns conducted in
Arabia EPTR_C, 51Ni/c, 50V, 51V, 67, 67N, Tecnalia Lab in Based on S&SD letter S&SD letter
Plant -Zamudio, Biscay, Spain 0545722590 67G, 67Ns, 67P, 67Q, 67Ni/c, 85, 50FD, Spain as per EMC #MPQ46077915, MPQ46087215 and
ziad.najjar@zivautomatio Phase Selector, 46, 37, 27 (under test report # MPQ46097315 all dated January 01, 2023, the
Polígono Parque Tecnológico, 210, n.com voltage), 59 (over voltage), 59N, 64, B45-22-AL-11 dated manufacturer is pre-qualified for Protection Relay
48170 Zamudio, Biscay, Spain 47, 49, 81M (over frequency), 81m 30/06/2022, Climatic Type: IRF for rated voltage 380kV and below as
(under frequency),, 81D, Load test report # conforming to National Grid SA specification #
Bilbao Shedding, 25 (synch check relay), B45-22-AG-12 41-TMSS-01, with the following conditions:
32P/Q, 50BF, 78, cold load, 59V/Hz, dated 16/06/2022
Contact Person - Ziad Najjar 87N, 60VT, 60CT, 79, Sequence and Mechanical test WARRANTY
Phone - +34944522003 Coordination, Coil Supervision report #
Email ID - [email protected] (Depending on the Hardware B45-22-AG-11 dated Ten (10) years extended warranty/guarantee to
Contact Person Email ID - Selection), Breaker Supervision, Fault 15/06/2022. SEC/National Grid SA for the offered Protection
[email protected] Locator, Transducer Voltage Relay Type: IRF for rated voltage 380kV and
Website - Supervision 1, Pole Discrepancy, Open below in respect of the defects due to design,
https://www.zivautomation.com/ Pole Detector , Dead Line Detector, manufacturing, installation and workmanship from
Saturation Detector , Harmonics the date of Provisional Acceptance Certificate
Blocking., I/O. High Impedance Busbar (PAC) of the first turnkey project (in case of
protection, Bus Section/coupler & contract award) or from the date of first delivery
Feeder management relay (in case of direct material supply order), as
confirmed by the manufacturer, through their
Letters Ref. # MPQ 46077915-cycle 3 dated
• Communication : September 11 2022, MPQ 46087215-cycle 3
Bonding, RSTP, PRP and HSR dated September 11/ 2022, MPQ 46097315-cycle
Redundancy. 3 dated September 11/ 2022 and MPQ
IEC 61850 Ed.2, DNP3.0, Modbus RTU 56977715-cycle 12 dated January 29/ 2021.
and PROCOME Protocols.
Time synchronization by IRIG-B, SNTP
and PTP (Ordinary Clock / Transparent
Clock).

Total = 9

15. 1 Page 460 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PROTECTIVE RELAYS
15. 2
132 KV and Below Applicable Standards: 41-TMSS-01

15. 2 Page 461 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE MULTILIN T 60
CANADA

Markham , Canada Function:


87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE

Hardware:
2-WINDING:
15xCT(Ph)+5xCT(Gnd)
8xcontact inputs
4xcontact outputs
3-WINDING:
IEC 61850 2-ports

Ordering code:
T60-K22-HKH-F8F-H6L-M8N-P6T-U8N-
WXX

Built in Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff

50/51PH&GR all windings.


67P/67N(All windings)

15. 2 Page 462 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE

Hardware:
3-WINDING:
15xCT(Ph)+5xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports

C70

Functions:
27P
50/51 P&G
Undercurrent
50 2
59B&59N
59 2
Harmonic Overload
60P&N
87V phase&neutral
67 P&G
67 2
60 VT Supervision
DFR/SOE

Hardware:
6CT+6VT+16BI’s+20BO’s
IEC 61850,2-PORTS

15. 2 Page 463 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SEL Sel Khobar Type/Model - 487E


United States Contact Person: Omar
Yosef,PO Box 32191 Function:
Website - Khobar 31952 87L (dual combined slope)
http://www.selindustrial.com/ www.selinc.com 87 REF (low impedance)
Email - omar 87/50 Instan Diff
[email protected] 50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
60
DFR/SOE

Hardware:
2-WINDING:
8xcontact inputs
4xcontact outputs
3-WINDING:
15xCT(Ph)+3xCT(Gnd)

IEC 61850 2 ports

SEL421

Function:
Control & MIMIC
21 P&GD
50N/51 P&G
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking

15. 2 Page 464 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

Hardware:
15BI+23 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC

15. 2 Page 465 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ZIV Innovative Systems Type/Model - IDV-Protection IED for


SPAIN (isys) Transformer
PO Box 60606, Riyadh
Smart Grid Excellence Center Zamudio , 11555 Function:
Bizkaia/ Spain Parque Tecnologico 210. Phone - 87L (dual combined slope)
48170 Zamudio, Bizkaia -Spain Madrid , +966-11-460-8161 87 REF (low impedance)
Spain Email - 87/50 Instan Diff
[email protected] 50/51PH&GR all windings.
Contact Person - Mr. Ibon Bermejo 67N/67N(All windings)
Email ID - [email protected] 27/59/25
Website - 81 U/O
http://www.gridautomation.ziv.es 50 BF
49T
24
74 DC supply supervision.
74 Lockout Coil Supervision.
CT Super (All windings)
60
DFR/SOE
Hardware:
2-WINDING:
9xCT(Ph)+2xCT(Gnd)
8xcontact inputs
4xcontact outputs
3-WINDING
IEC 61850 2 ports

8IDV

Function:
87L (dual combined slope)
87 REF (low impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67N/67N(All windings)
50 BF
49T

74 DC supply supervision.
74 Lockout Coil Supervision.
CT Super (All windings)

15. 2 Page 466 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DFR/SOE

Hardware:
3-WINDING:
12xCT(Ph)+2xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports

Other Type:
6RTV
AVC

Total = 3

PROTECTIVE RELAYS
15. 3
33 KV and Below Applicable Standards: 41-TMSS-01

15. 3 Page 467 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SEL SEL-451
United States

Website - Function:
http://www.selindustrial.com/ Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

Hardware:
16BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC

15. 3 Page 468 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SCHNEIDER ELECTRIC Type/Model - Sepam-80,


(TELEMECANIQUE) Rating - 13.8 kV Test Date - April
FRANCE following optional modules needs to be 2009
ordered..
Website - 1. MES120 (59715) #2 nos.
http://www.schneider-electric.fr/ 2. ACE850F0 interface module
(59659) # 2 no.
3. ACE850 communication cable
(CCA614) # 2 no.

Function:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

Hardware:
14BI+6 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC

15. 3 Page 469 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS SIEMENS Ltd Saudi TYPE 7SJ8x PQ Letter:


GERMANY Arabia Function: Based on S&SD letter # 17-00825-30504401
Khaleel.al-adani@siemen dated March 14, 2017, Siemens Berlin, Germany
Berlin, Germany s.com Control & MIMIC is pre-qualified for (SIPROTEC 5) as conforming
IC SG EA MF Local: Mr. Khaleel High Impedance Protection to National Grid SA specification # 41-TMSS-0
Wernerwerkdamm 5, Al-Adani 50N/51 P&GD
13629, Berlin, Germany Mob: +966 505892043 67P/67N WARRANTY:
+966126618831 49 Thermal Overload Ten (10) years extended warranty from the date
Phone - +49 (911) 433 8321 Khaleel.al-adani@siemen Phase Unbalance 46 of PAC of the first turnkey project (in case of
Website - s.com Undercurrent 37 contract award) or date of first delivery (in case
www.siemens.com/ingenuityforlife 27/59 of direct material supply order), as confirmed,
Auto reclosure 79 through their letter # EA PRO/Pz, dated April 22,
50BF 2014 shall be applicable for all (SIPROTEC 5
Trip circuit Supervision 74TC Relays) to be supplied to SEC/National Grid SA.
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

Total = 3

PROTECTIVE RELAYS
15. 4
13.8 KV and Below Applicable Standards: 41-TMSS-01

15. 4 Page 470 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE MULTILIN F650
SPAIN
Functions:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE

Hardware:
16BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC

15. 4 Page 471 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NR ELECTRIC CO. LTD, PCS 9611 PQ Letter


CHINA Based on S&SD letter# 13-07186-1-30504401
Function: dated December 23, 2013, it is pre-qualified for
Nanjing , China Control & Mimic 13.8 kV Plain OH Feeder + UG + Incomer Relays,
50N/51 P&GD with the following condition:
67P/67N
49 Thermal Overload WARRANTY:
Phase unbalance 46 Ten (10) years extended warranty/guarantee in
Under Current 37 respect of defects due to design, manufacture,
27/59 installation & workmanship from the date of PAC
Auto reclosure 79 of the first turnkey project in case of contract
50BF award and subsequently reduced yearly in case
Trip Circuit Supervision 74TC of future project award. This was confirmed in
Inrush Blocking writing by the manufacturer through their letter #
Under / over frequency 81 NR-SEC-20110829-CL2 dated August 29, 2011.
CT Supervision
60 (VT Fuse Supervision )
Sensitive earth element function
Second harmonic detection
DFR / SOE

Hardware:
16 BI+ 07 BO
3CT(Ph) + 1CT(GD)+3VT
IEC 61850, 2-Optical Ports PRP

Total = 2

PROTECTIVE RELAYS
15. 5
Auxiliary Relays Applicable Standards: 41-TMSS-01

15. 5 Page 472 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Electrotecnica ARTECHE Hermanos, Auxiliary Relays Types: PQ Letter


S.L. VDF- 10 125 VDC Based on S&SD letter # 14-10095-030504401
SPAIN dated 31
built-in function: Trip circuit supervision December 2014, the manufacturer is prequalified
Plant -Mungia, Spain - single phase, LED for
indication and two contacts. Relay type VDF- 10,
Electrotecnica ARTECHE Hermanos, VDJ- 30 125 VDC Relay type VDJ- 30,
S.L. Relay type RTU-4,
DERIO BIDEA, 28 (Bº Zabalondo) built-in functions: Trip circuit Relay type RJ-8,
48.100 - MUNGIA Spain supervision-- three phase, Relay type RF-4,
LED indication and two contacts. Relay type BJ-8 RP,
Mungia Relay type BF-4 RP,
RTU-4 125 VDC Relay type TDJ-8,
Contact Person - LANDER ZUGAZAGA built-in Relay type TDF-4,
& Kamal Al Muhanna functions: Auxiliary supply supervision, with the following condition:
Phone - +34 94 601 1200 Self-Reset, LED
Email ID - [email protected] indication and (4) contacts. WARRANTY:
Contact Person Email ID - RJ-8 125 VDC Op: 01101 Ten (10) years extended warranty from the date
[email protected] & [email protected] of PAC of the first turnkey project in case of
Website - www.arteche.es built-in functions: Auxiliary Control, contract award and subsequently reduced
Self-Reset and (8) yearly (in case of future project award) . and
contacts. from the date of first delivery in case of direct
RF-4 125 VDC Op: 01101 material supply order. This was confirmed in
writing by the manufacturer through their letter
built-in functions: Auxiliary Control, SEC030214 Annex dated February 03, 2014.
Self-Reset and (4)
contacts.
code BJ-8 RP 125 VDC

built-in functions: CT shorting


application, flag indication,
electrical and hand reset and (8)
contacts.
BF-4 RP 125 VDC

built-in functions: CT shorting


application, flag indication,
electrical and hand reset and (4)
contacts.
TDJ-8 125 VDC
built-in
functions: time-lag, LED indication, (8)

15. 5 Page 473 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

timed contacts (10


functions,16 timing ranges from 30ms
to 99 hours).
&
Relay type TDF-4
built-in
functions: time-lag, LED indication, (4)
timed contacts (10
functions,16 timing ranges from 30ms
to 99 hours).

Hitachi Energy Sweden AB Hitachi Energy Type/Model – combiflex RXMVB2 Mfr. Name change from ABB Sweden AB to
SWEDEN Hitachi Energy Ltd. Hitachi Energy Sweden AB
Riyadh, Saudi Arabia Built in Function:
Plant -Natverksgatan 3 Bnr 391: 721 36 Phone: +966 11 2181703 CT Shorting
Vaesteras Mobile: +966 500414555 Hardware:
paulus.ralhana@hitachie
Contact Person - Mr. Paulus Ralhana nergy.com
(manager) Other Type:
Email ID - RXKL1
[email protected] Timer
Contact Person Email ID -
[email protected] RXMB1
Website - www.hitachienergy.com
RXMVB4
In/Out relay

RXSF1
DC supervision

SPER 1C1
Trip circuit supervision

15. 5 Page 474 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS AR 901
United Kingdom
Function:
Plant -New Castle CT Shorting

SIEMENS SPDL – REYROLLE UK Hardware:

Contact Person - Mr. Andrei Coman


Phone - +44 7921 876806 Other Type:
Email ID - [email protected] 2V68S
Website - CT Supervision
https://w3.siemens.com/smartgrid/glob
al/en/products-systems-solutions/prote Other Type:
ction/reyrolle/pages/overview.aspx AR111

DDB20
Timer

XR152
DC supervision

XR350
27TC

15. 5 Page 475 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

UK Grid Solutions Ltd-UK MVTP31


United Kingdom
Built in Function:
United Kingdom CT Supervision

Hardware:

Other Type:
MVAA
multiplication relay

MVAJ104
In/Out relay

MVAJ34
in/out relay

MVAX12
DC supervision

MVAX31
Trip circuit supervision

MVTT14
Timer

15. 5 Page 476 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Relay Monitoring Systems Pty Ltd Energy Shields Alpha-AR: Built-in functions; auxiliary Type Tests were PQ Letter
AUSTRALIA 7444 Uthman Ibn Affan relay with hand reset flag or without, successfully Based on S&SD letter #MPQ88587815 dated July
Branch Rd, 4333, At variants with 5, 10 or 12 contacts (any conducted on 15 16, 2023, the manufacturer is prequalified for
Plant -Australia Taawun, Riyadh7444 combination NO+NC) January 2023 in Auxiliary Relays as confirming to National Grid SA
Uthman Ibn Affan Branch Alpha-XR: Built-in functions; DC Alter Technology specification #41-TMSS-01, with the following
19 Southern Court, Keysborough Rd, 4333, At Taawun, supervision and trip circuit supervision TUV NORD conditions:
Riyadh relay with 5 contacts (any combination Laboratory, Madrid,
Melbourne +966503733222 NO+NC) Spain.
mohammed.almarzouq@ Delta-ARD: Built-in functions; auxiliary WARRANTY
Contact Person - G Venkat es-sp.com relay with hand reset flag or without, 4 Ten (10) years extended warranty/guarantee to
Phone - +61385441200 contacts SEC/National Grid SA for the offered Auxiliary
Email ID - [email protected] Delta-XRD: Built-in functions; DC Relays, Test Terminal Block and Test Plug in
Contact Person Email ID - supply supervision and trip circuit respect of the defects due to design,
[email protected] supervision relay with self-reset manufacturing, installation and workmanship from
Website - www.morssmitt.com contact, hand reset flag and LED, 2 or the date of Provisional Acceptance Certificate
4 contacts (PAC) of the first turnkey project (in case of
2V68-S-xxx: Built-in functions; CT contract award) or from the date of first delivery
supervision and shorting relay with (in case of direct material supply order), as
harmonic filter, 3 latching contacts confirmed by the manufacturer, through their
6RA206-xx: Built-in functions; CT Letter Ref. #AF/NG/01/2020, dated June 16,
shorting relay, 3 latching contacts 2020.
4M series: Built-in functions; Finger
save test terminal block with optional
automatic CT shorting.
4M series: Built-in functions; Finger
save test plug.

Total = 5

PROTECTIVE RELAYS
15. 6
Tripping and Lockout Relay Applicable Standards: 41-TMSS-01

15. 6 Page 477 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Electrotecnica ARTECHE Hermanos, Relay type BI-16R HB Type Tests PQ Letter


S.L. 125 VDC Standard Specification: High conducted in Based on S&SD letter # 14-10095-030504401
SPAIN burden, flag indication, electrical reset, Tecnalia (Derio) and dated 31 December 2014, the manufacturer is
16 Contacts Arteche (Mungia) - prequalified for Latched Tripping and lockout
Plant -Mungia, Spain make and carry (3 sec) AC/DC Spain from Relay type BI-16R HB, Latched Tripping and
7500VA/w with max 30A, 300V. 08/03/2020 to lockout Relay type BI-16RP HB
Electrotecnica ARTECHE Hermanos, Breaking capacity DC 125w resistive, 12/03/2021. Type Unlatched Tripping Relay type RI-16R HB,
S.L. 60w inductive (L/R = 40ms). tests report no. # ordering code: BI-16RP HB 125 VDC op: 01000,
DERIO BIDEA, 28 (Bº Zabalondo) B28-21-AF-01E. with the following condition:
48.100 - MUNGIA Spain BI-16R HB 125 VDC
ordering code: BI-16RP HB 125 VDC, WARRANTY:
Mungia Standard Ten (10) years extended warranty from the date
Specification: High burden, flag of PAC of the first turnkey project in case of
Contact Person - LANDER ZUGAZAGA indication, electrical and contract award and subsequently reduced
& Kamal Al Muhanna hand reset, 16 Contacts make and yearly (in case of future project award) . and
Phone - +34 94 601 1200 carry (3 sec) AC/DC from the date of first delivery in case of direct
Email ID - [email protected] 7500VA/w with max 30A, 300V. material supply order. This was confirmed in
Contact Person Email ID - Breaking capacity DC writing by the manufacturer through their letter
[email protected] & [email protected] 125w resistive, 60w inductive (L/R = SEC030214 Annex dated February 03, 2014.
Website - www.arteche.es 40ms).
&
RI-16RP HB 125 VDC op: 01000 PQ Letter
Standard Specification: Based on S&SD letter # OMPQ46497815 dated
High burden, LED indication, Self-reset, June 20, 2021, the manufacturer is prequalified
16 Contacts make for Auxiliary Relays (Tripping and Lockout
and carry (3 sec) AC/DC 7500VA/w Relays) confirming to National Grid SA
with max 30A, 300V. specification # 41-TMSS-01 with the following
make and carry continuous AC/DC conditions:
1250 VA/w with max of
5A, 300V. DC 80w resistive, 40w WARRANTY
inductive (L/R = 40ms) Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
BJ10RP HB (10 contacts) contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter No. SEC01210603 dated June
03, 2021, shall be applicable for the equipment to
be supplied to SEC/National Grid SA.

15. 6 Page 478 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS TR241
United Kingdom
Standard Specification :
Plant -New Castle Hand & Electrical Reset
High Burden
SIEMENS SPDL – REYROLLE UK Flag indication, hand reset
Up to 10 contracts (in any
Contact Person - Mr. Andrei Coman configuration)(8 NO & 2 NC)
Phone - +44 7921 876806 Standard Hand Reset Flag Available
Email ID - [email protected] Operating Time in ms. (10ms)
Website - Contact Ratings:
https://w3.siemens.com/smartgrid/glob (Make & Carry (3 sec))AC/DC:
al/en/products-systems-solutions/prote 7500VA/W with Max of 30A,300V
ction/reyrolle/pages/overview.aspx (Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Note-Withdrawable from Case
TR212

Standard Specification :
Self Reset
High Burden
Flag indication, hand reset
Up to 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)

Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with

Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Note-Withdrawable from Case

15. 6 Page 479 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

UK Grid Solutions Ltd-UK MVAJ


United Kingdom
MVAJ101
United Kingdom
Standard Specification :
Self Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)

Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)

Note-Withdrawable from Case

MVAJ105
Standard Specification :
Hand & Electrical Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)

Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w

15. 6 Page 480 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Inductive (L/R=0.04sec)
Note-Withdrawable from Case.

15. 6 Page 481 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELECTRO-SWITCH LOR/HR
United States
LOR/HR-
Website -
http://www.electroswitch.com/ Standard Specification :
Hand & Electrical Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)

Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)

LOR/SR-

Standard Specification :
Self Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)

Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)

15. 6 Page 482 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RELAY MONITORING SYSTEM (RMS) Relays group of High Speed Tripping Relay , Type test witnessed PQ Letter
AUSTRALIA Companies Type: 6RJ21 by three Based on S&SD letter # 15-02815-2-030504401
P.O. Box 101709 , SEC/National Grid dated 30 June 2015, the manufacturer is
6 Anzed Court Mulgrave 3170 Riyadh 11665 Kingdom High Burden Tripping Relay , SA Engineers during prequalified for: High Speed Tripping Relay, Type:
Melbourne Victoria Australia Po Box of Saudi Arabia Type: 6RJ25 25th May-3rd June 6RJ21
1166 Huntingdale Tel: 00 9661 Ordering Code: 6RJ25-10-D-8M2B 2015.
4727902/4724320/47324 Test were As conforming to National Grid SA specification #
Contact Person - Mr. Alphonse 61 - Fax: 00 966 Conducted in RMS 41-TMSS-01,
Fernandez Export Manager E-Mail: Lab and Report No. Rev.0 with the following condition:
Phone - +61-3-8544-1200 [email protected] 19301901001 (TUV)
Email ID - [email protected] , om, rbakshi@erelays SEC Report#Nil WARRANTY:
[email protected] Dated 14-10-2014 Ten (10) years extended warranty from the date
Website - http://www.rmspl.com.au of PAC of the first turnkey project in case of
contract award and subsequently reduced
yearly (in case of future project award). and
from the date of first delivery in case of direct
material supply order. This was confirmed in
writing by the manufacturer, as confirmed by the
manufacturer thru letter #nil dt: Nov 07, 2013.

Relay Monitoring Systems Pty Ltd Energy Shields Alpha-TR: Built-in functions; High Type Tests were PQ Letter
AUSTRALIA 7444 Uthman Ibn Affan burden, high speed trip & lockout relay successfully Based on S&SD letter #MPQ88587815 dated July
Branch Rd, 4333, At with hand reset flag or without flag, conducted on 15 16, 2023, the manufacturer is prequalified for
Plant -Australia Taawun, Riyadh variants with 5 or 12 contacts (any January 2023 in Auxiliary Relays as confirming to National Grid SA
+966503733222 combination NO+NC). Alter Technology specification #41-TMSS-01, with the following
19 Southern Court, Keysborough mohammed.almarzouq@ Delta-TRD: Built-in functions; trip & TUV NORD conditions:
es-sp.com lockout relay with hand reset flag or Laboratory, Madrid,
Melbourne without flag, variants with 4 or 8 Spain.
contacts. WARRANTY
Contact Person - G Venkat Ten (10) years extended warranty/guarantee to
Phone - +61385441200 SEC/National Grid SA for the offered Auxiliary
Email ID - [email protected] Relays, Test Terminal Block and Test Plug in
Contact Person Email ID - respect of the defects due to design,
[email protected] manufacturing, installation and workmanship from
Website - www.morssmitt.com the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. #AF/NG/01/2020, dated June 16,
2020.

Total = 6

15. 6 Page 483 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Fault Recorder/Locator
16. 1
DIGITAL/TRANSIENT FAULT RECORDERS Applicable Standards: 41-TMSS-02

QUALITROL HATHAWAY Adwan Marketing Co.


NORTHERN IRELAND (AMC)
PO Box 64273, Riyadh
Plant -Belfast 11536
Kingdom of Saudi Arabia
15 Wildflower Way, Belfast, BT12 6TA. +966-11-495-5332
UK Ext:112
[email protected]
Belfast om

Contact Person - Craig Sommerville


Phone - +44 1415 721251; +44 7703
685829;
Contact Person Email ID -
[email protected]
Website - www.qualitrolcorp.com

16. 1 Page 484 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KoCos Messtechnik Germany Mohammed Al-Ojaimi SHERLOG CRX •Fault Record PQ letter:
GERMANY Contracting Est. System Report # Based on S&SD letter # 17-06723-030504401
KoCoS Messtechnik AG (E170309E1) by dated October 31, 2017, KoCos Messtechnik
Plant -Korbach, Germany Suedring 42 Phoenix TestLab – Germany is pre-qualified for Digital Fault
D-34497 Korbach, Germany Recorder (DFR) as conforming to latest National
KoCoS Messtechnik AG Germany •DFR & DSM Report Grid SA specification # 41-TMSS-02
Suedring 42 Tel. +49 5631 9596-0 # (U170309E1) by
D-34497 Korbach, Germany [email protected] Phoenix TestLab – WARRANTY:
Germany Ten (10) years extended warranty/guarantee in
Korbach •Functional Test respect of defects due to design, manufacture,
Report # Nill by installation and workmanship from the date of
Contact Person - KoCos Germany KoCos Messtechnik Provisional Acceptance Certificate (PAC) of the
(Lea-Sophie Kotthoff, Sales), Local – Germany first turnkey project in case of contract award or
Agent- Mohammed Al-Ojaimi date of first delivery in case of direct material
Contracting Est. (Abbad S. Ahmed, supply order, as confirmed by the manufacturer
Manager Energy Services.) vide letter # Nil, dated May 27, 2015.
Phone - Tel. +49 5631 9596-0
Email ID - [email protected]
Contact Person Email ID -
[email protected]
[email protected]
Website - www.kocos.com

DIgSILENT Al Haider For Trading & PFM 300 Type tests were Letter
GERMANY Contracting conducted in Based on S&SD letter # 16-10016-030504401
P.O. Box 18. Ras Tanura, DigSILENT test lab dated December 25, 2016, DIgSILENT,
Plant -Gomaringen Germany 31941,m KSA and S-Team Gomaringen Germany is pre-qualified for Digital
+966 3 667 0552 / 667 Electronic test lab Fault Recorder type PFM 300 as conforming to
Heinrich-Hertz-Strabe 9 3700 / 667 1660 during 21st to 23rd National Grid SA specification # 41-TMSS-02
72810 Gomaringen alhaiderpersonnel@yaho September 2016 Rev.0, with the following condition:
o.com /
Contact Person - Dr. Martin Schmieg, [email protected] warranty
Managing Director •Ten (10) years extended warranty from the date
Contact Person Email ID - of PAC of the first turnkey project (in case of
[email protected] contract award) and date of first delivery (in
Website - http://www.digsilent.de case of direct material supply order), as
confirmed, through their Letter No. Nill dated 12
August 2014 shall be applicable for all supplies to
the Company by DIgSILENT, Gomaringen
Germany

16. 1 Page 485 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AMETEK (ROCHESTER)
United States

Plant -ROCHESTER, NY

255 North Union Street


Rochester, N.Y. 14605
United States

ROCHESTER, NY

Contact Person - Sal Cardella- Product


Marketing Manager, Steve Bleier -
Director of Marketing and Business
Development
Phone - 001-585-263-7700
Email ID - [email protected]
Contact Person Email ID -
[email protected] ,
[email protected]
Website - www.ametekpower.com

ERL PHASE POWER TECHNOLOGIES Diyar Al Mobtekroon Int. TESLA 4000 Based on S&SD letter # 15-01879/02-030504401
LTD Co.\PO Box 89109 dated April 28, 2015, the manufacturer is
CANADA Riyadh 11682 KSA prequalified to supply Fault Recorder with the
Eng. Ali Al Ameel following conditions:
74 Scurfield Blvd, Winnipeg, Mb [email protected]
Canada R3Y 1G4 [email protected] - Ten (10) years extended for the Fault recorder
from the date of PAC of the turnkey project in
Contact Person - Mr. Ramaswami case of contract award or date of delivery in
Bharath case of direct material supply order. as
Phone - +204-477-0591 , confirmed through the manufacturer letter # Nil
Email ID - [email protected] dated 18.10.2013.
Website - http://www.erlphase.com

Total = 5

CAPACITOR
17. 1
SHUNT CAPACITOR BANK, 13.8KV THROUGH 380KV Applicable Standards: 43-TMSS-01

17. 1 Page 486 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GRID SOLUTIONS OY LTD. Previously " Nokian Capacitors Ltd. –Finland", the
FINLAND name has been changed to Areva T&D Ltd. –
Finland based on TS&SD/ESD Letter #
Tampere , Finland 10-00145-03032301 dated January 16, 2010 and
P.O.Box 4, Kaapelikatu 3 fl-33331 Areva T&D Ltd.-Finland Letter # Nil dated January
Vehmaistenkatu 5 fl-33730 04, 2010, then the name has been changed again
to ALSTOM Grid Ltd. –Finland based on Dept Mgr,
Phone - +358 3 388311 S&SD E-mail dated February 26, 2012 and
Email ID - [email protected] ALSTOM Grid Ltd. letter # RN-2012-02-18 dated
Website - www.gegridsolutions.com February 18, 2012.

PREVIOUSLY ALSTOM GRID Oy (LTD.)

EATON UNITED STATES-GREENWOOD Previously “COOPER (MCGRAW-ED)”, the name


(SC STATE) has been changed to “Eaton” based on
United States S&SD/P&SFD letter # 15-04107-30504401 dated
May 19, 2015 and COOPER (MCGRAW-ED) letter
Website - # 01110502015 dated May 11, 2015
http://www.cooperindustries.com/inde
x.cfm

SAMWHA CAPACITOR CO. LTD Type / Model: Shunt Capacitor Banks PQ Letter:
KOREA, Republic of TS&SD Letter # 11-02016/01-03032301 dated
Rating: 13.8kV to 36kV Only 06/07/2011, it is pre-qualified for Substation Type
13.8kV to 36kV Only Shunt Capacitor Banks.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.nil, dt: 12/03/2010..

17. 1 Page 487 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SCHNEIDER ELECTRIC Electrical Power CP 229 Type Test conducted PQ Lettter


FRANCE Distribution Board & 13.8 kv in CESI/FGH Based on S&SD letter # 15-07331-07-30504401
Switchgear Ltd. 685 kBST 9930 V Manheim , Germany dated March 03, 2015, the manufacturer is
Plant -France-Pringy PO Box.89249 Riyadh Laboratory on 12th prequalified to supply MV capacitor banks Type #
11682 to 15th January CP 229 (13.8 kV) only, with the following
Contact Person - Mr. Ahmed Majrashi Tel:01-265-1515 2013 in FGH condition:
Email ID - Engineering & Test
[email protected] GmbH Laboratories WARRANTY
m Hallenweg Ten (10) years extended Warranty for the
Germany. proposed MV
Report#H 15002 Capacitor Bank in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of
the Provisional Acceptance Certificate (PAC) of
the project (in case of contract award) and from
the date of delivery for the direct material supply
order as confirmed through the Manufacturer
letter # Nil dated 11.09.2011.

VISHAY ELECTRONICS Suspended for all SEC/National Grid SA ongoing


CZECH REPUBLIC and forthcoming projects based on VP,
Engineering letter # 14-06522-30504401 dated
Blatna , Czech Republic September 03, 2014.

17. 1 Page 488 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. CHDX, CHDB/ Shunt Capacitor Bank (18 January to 11 Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia (Q-Bank) March 2021), FGH and changed to Hitachi Energy Ltd.
Rating: 13.8kV through 380kV CESI lab Germany
Plant -Dammam PQ Letter
Based on S&SD letter # OMPQ35358417 dated
PO: 41022, Street 39 cross 144, 2nd June 01, 2021, the manufacturer is prequalified
Industrial City, Dammam 31521, Saudi for Shunt Capacitor Bank , 13.8KV Through
Arabi 380KV confirming to National Grid SA
specification # 43-TMSS-01 with the following
Dammam conditions:

Contact Person - Abdulmajeed WARRANTY


Alothman ; Mr. Abdullah Hamidaldin ; Ten (10) years extended warranty from the date
Mr. Jochen Kiefer of PAC of the first turnkey project (in case of
Phone - +966 11 2181703; +966 contract award) or date of first delivery (in case
500414555 of direct material supply order), as confirmed,
Email ID - through their Letter No. CBGWC2020.02 dated
[email protected] February 04, 2020 shall be applicable for the
m; equipment to be supplied to SEC/National Grid SA.
[email protected]
m; [email protected]

17. 1 Page 489 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE Grid Solutions LLC Type / Model: Capacitor Bank PQ Letter:


United States TS&SD fax ref. # 08-F0623/01-03032301, dated
Rating: 13.8kV through 380kV 02/12/2008. Pre-Qualified for Capacitor Bank
Plant -Florida (13.8kV through 380kV) .

1925 Calumet Street CONDITION:


Clearwater, FL 33765 First batch shall be type test in an independent
laboratory in presence of (3) SEC engineers &
Phone - +1 678228 4169 (1) independent inspector.
Email ID - [email protected]
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

NEW WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of project award)
and from the date of delivery for the direct
material supply order, as confirmed by the
manufacturer vide letter # Nil, dated May 01,
2017.

Previously " GENERAL ELECTRIC


ENERGY-CPQP", the location has been changed
from NEW York-USA to Clearwater, Florida-USA ,
based on S&SD letter # 18-01810-1-30504401
dated June 10, 2018

Total = 7

BATTERIES AND POWER SUPPLIES


18. 1
VENTED TYPE LEAD ACID STATIONARY BATTERY Applicable Standards: 46-TMSS-01

18. 1 Page 490 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BAE BERLINER BATTERIE FABRIK- G


GERMANY

Website - http://www.bae-berlin.de/

Exide Technologies SAS Note:


FRANCE Previously " CEAC", the name has been changed
to "
Exide Technologies SAS ". based on their letter #
Nil dated November 28,
2017.

ENERSYS S.A.R.L. Vented Lead Acid Batteries


FRANCE PREVIOUSLY KNOWN AS HAWKER S.A.R.L –
FRANCE.
Plant -France
WARRANTY:
Enersys S.A.R.L, Z.T.Est- P O Box 962, Five (05) years extended warranty/guarantee in
62033 Arras-Frace respect of defects due to design, manufacture,
installation & workmanship from the date of
Contact Person - Mr. Gilles Provisional Acceptance Certificate (PAC) of the
Gourgouilhon first turnkey project in case of contract award or
Phone - +33(0)321 60 2525 date of delivery in case of direct material supply
Email ID - order.
[email protected]
Website - http://www.enersys.com

FIAMM
ITALY

Website -
http://www.fiamm.com/index.aspx

GOULD (GNB)
United States

Website - http://www.goulds.com/

HOPPECKE Cell
GERMANY Up to 24 OPzS

Website - http://www.hoppecke.com/.

18. 1 Page 491 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TOVARNA AKUMULATORSKIH BATERIJ


SLOVENIA

Website - http://www.tab.si/

TUNGSTONE (HAWKER TUNGSTONE)


United Kingdom

Website - http://tungstonepower.com/

YUASA
JAPAN

Website -
http://www.yuasabatteries.com/

C&D
United States

Website - http://www.cdtechno.com/

EXIDE
United States

Website - http://www.exide.com/

VARTA Battery Cell


GERMANY OPzS

Website - http://www.varta.com/

Total = 12

BATTERIES AND POWER SUPPLIES


18. 2
BATTERY CHARGERS Applicable Standards: 46-TMSS-02

18. 2 Page 492 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Eram Power Electronics Co. Model L3-12-350 PQ Letter


Saudi Arabia Based on S&SD letter#18-00008-01-30504401.
Rectifier type: SCR Controlled Rectifier dated January 06, 2019, the manufacturer is
3rd Industrial Area, Road No 22, 3rd prequalified for 125V DC Battery Charger Model
Industrial Area, Dammam 34856 Input: L3-12-350 as confirming to SEC specification #
Voltage: 400VAC, ±10%, 3Ø 46-TMSS-02, Rev.01, with the following
Dammam conditions:
Frequency: 60Hz, ±5%
Contact Person - Jacob CONDITION:
Thomas-Business Unit Manager Output: 125VDC All Type, Routine and Special testes shall be
Phone - +966138404500 carried out on the first batch of 125V DC Battery
Email ID - [email protected] Charger Model L3-12-350 in an Independent
Contact Person Email ID - Testing Laboratory in the presence of three (3)
[email protected] SEC Engineers & one (1) SEC approved
Website - www.apec.sa.com Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter # #APEC
01/01/01 dated January 01, 2019.

WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #APEC
01/01/02 dated January 01, 2019.

Location has been changed from Al-Khobar to


Dammam:

WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order). as confirmed,
through their letter No. APEC2021010301 dated
03 January 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

18. 2 Page 493 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LEVER S.R.L. 125Vdc-400A Battery Charger type Based on S&SD letter# 16-03205-02-30504401
ITALY SME 125/400/SEC dated May 08, 2016, it is prequalified for
125Vdc-400A Battery Charger type
Plant -. SME 125/400/SEC as conforming to National Grid
SA Material Specification 46-TMSS-02 with the
Viale del Lavoro , 17-37024 Arbizzano following conditions:
(VR), Italy
•Ten (10) years extended warranty from the date
Contact Person - Mr. Llamettin of PAC of first Project in case of contract award
Canimoglu ,Sales Manager or from the date of delivery for the direct material
Email ID - [email protected] supply order and shall be subsequently reduced
Contact Person Email ID - yearly in case of future project, as confirmed by
[email protected] the manufacturer through letter#
GG/nm/28042016 dated 28-04-2016.

AEG POWER SOLUTIONS SAS Originally was SAFT Power System SAS-France
FRANCE

BENNING ELEKTROTECHNIK & SUSPENDED for supply of DC Battery Chargers


ELEKTRONIK GMBH & CO.KG. to SEC/National Grid SA for all ongoing and all
GERMANY future SEC/National Grid SA projects/purchase
orders based on VP, Engineering letter #
18-03214-1-30504401 dated October 08, 2018.

Previously "Theo-Benning-Germany", the name


has been changed to Benning Elektrotechnik &
Elektronik GmbH & Co. KG -Germany based on
TS&SD/ESD letter # 11-00334-03032301 dated
30/01/2011.

BENNING SUSPENDED for supply of DC Battery Chargers


FRANCE to SEC/National Grid SA for all ongoing and all
future SEC/National Grid SA projects/purchase
Website - orders based on VP, Engineering letter #
http://www.benning.fr/Anglais/nfrance 18-03214-1-30504401 dated October 08, 2018.
.htm

18. 2 Page 494 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BORRI S.P.A M/s Abunayyan Trading Type/Model - RTB.e The type test have PQ Letter:
ITALY P.O. box 321, Riyadh been conducted on S&SD Letter # 14-03226-01-030504401 dated
11411 Input 400 Vac 125 Vdc, 300 A June 4, 2014, pre-qualified for Battery Charger
Plant -Bibbiena(Arezzo) Italy Fax : +966 11 4764684 Output 125 Vdc battery charger at (125VDC, Type RTB.e).
Website : CETACE
Bossir S.P,A Via 8 Marzo. 2-52010 - www.abunayyangroup. Laboratories, 50018 WARRANTY:
Soci-Bibbiena, Italy com Scandicci (FI) – Italy Ten (10) years extended warranty/guarantee in
+966 11 4779111 from 18/03/2014 to respect of defects due to design, manufacture,
Contact Person - Mr.Paolo como 19/03/2014. Test installation & workmanship from the date of
Phone - +39-0575-5351 Report No. Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] TRP _064_14, Date: first turnkey project in case of contract award or
19/03/2014. date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through letter # Nil, dated May 23,
2011.

18. 2 Page 495 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BRAGA MORO Itea International Ltd Rating: 125 V PQ Letter:


ITALY 21st Floor - Tamkeen S&SD Letter 12-03794-01-30504401 dated
Tower, Al Yasmin - November 18, 2012, Braga Moro- Italy is
Plant -Milan , Italy Riyadh 13325 - KSA pre-qualified for Battery Chargers 125V DC.
Phone: 011 4207555
Via Canzo 4 20068 Peschiera Fax: 011 4655305 CONDITION:
Borromeo, Milano, Milan ,Italy All Type, Routine and Special testes as per
Mr. Nabeel Huda; Mr. National Grid SA Specifications shall be carried
Email ID - Edoardo Lando out on the First unit to be supplied to SEC/National
[email protected]; +966550051979; Grid SA of Battery Chargers 125V DC in an
[email protected].; +966506273359 Independent Testing Laboratory in the presence
[email protected] [email protected]; of three (3) SEC/National Grid SA Engineers &
Website - http://www.bragamoro.com/ [email protected] one (1) SEC/National Grid SA approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by Braga
Moro-Italy. This was confirmed in writing by
Braga Moro-Italy through their letter # SEC
Prequalification dated April 13, 2011.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by Braga Moro- Italy through
their letter # SEC Prequalification dated April 13,
2011.

C&D
United States

Website - http://www.cdtechno.com/

ERSKINE
United Kingdom

Website -
http://www.erskine-systems.co.uk/

18. 2 Page 496 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EXIDE
United States

Website - http://www.exide.com/

GUTOR ELECTRONIC LTD.


SWITZERLAND

Website - http://www.gutor.com/

JESUS MARIA AGUIRRE SA (JEMA) PQ Letter:


SPAIN S&SD Letter 12-00193-030504001 dated January
17, 2012, prequalified for Battery Charger.
Lasarte-Oria , Spain
CONDITION:
All Type, Routine and Special testes shall be
carried out on the first batch of each types of
Battery Chargers in an Independent Testing
Laboratory in the presence of three (3) SEC
Engineers & one (1) SEC approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil dated June 17, 2011.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated June
17, 2011.

18. 2 Page 497 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

STATRON AG Type / Model: BDT Type test have been PQ Letter:


SWITZERLAND conducted for 125 V Based on S&SD letter # 15-10510-01-30504401
Rating: 125V DC Battery Charger dated January 10, 2016, it is pre-qualified for
Plant -Maegenwil 125BDT800 from Battery Chargers 125V DC (Models BDT) as
19th to 23rd May, conforming to National Grid SA specification #
Industrie Nord Ch-5506, Maegenwil , 2014 at Statron AG 46-TMSS-02, with the following remaining
Switzerland condition:

Contact Person - Mr. Marcel Bond WARRANTY:


Phone - + 41-62-887-4-887 Ten (10) years Extended Guarantee / Warranty
Email ID - [email protected] from the
date of PAC of first Project (in case of contract
award) or from
the date of delivery for the direct material supply
order is applicable. This has been confirmed by
the manufacturer
Statron AG through their Letter # bm dated
August 13, 2012.

CEG, BIBIENA PQ Letter:


ITALY TS&SD letter# 09-F001363/02-03032301 dated
2nd May 2009 & S&SD letter #
Website - 14-05308-01-30504401, dated 21st July, 2014.
http://www.cegelettronica.com
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

18. 2 Page 498 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Chloride S.A.S Project Execution Previously "AEES ", the name has been changed
FRANCE Development Co. Ltd to Emerson Network Power Industrial Systems -
(PEDCO) France based on Emerson Network Power
Plant -Previously AEES & Emerson 011 4648970, 2312462, Industrial Systems letter # nil dated 12/04/2013.
Network Power Industrial System 4169319 Then, the name has been changed again to
S.A.S Mr. Ilamettin Canimoglu, VERTIV Industrial Systems S.A.S based on
[email protected] VERTIV Industrial Systems S.A.S letter # nil dated
Lyon , France 29/06/2017.

Lyon

Contact Person - Mr.


Krishnendu.Chakrabarti , Mr.
Jean-Baptiste.Trolle
Contact Person Email ID -
[email protected],
[email protected]
Website - www.VertivCo.com

EMISA (ELECTRO MERCANTIL


INDUSTRIAL S.A. )
SPAIN

Website -
http://www.emisa.es/web/index.asp?l
ang=ing

18. 2 Page 499 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SALICRU S.A IBR-international DC POWER L series, Model: The type test have PQ Letter:
SPAIN Business Resources 2/DC-500-LP 125 EE635812-7 been conducted on Based on S&SD letter #MPQ45888618-Class I(b)
Mr. KHALID AL QUTHMI 125 V DC, 500 A -2018, dated March 05, 2023, the manufacturer is
Plant -HEADQUARTERS - Avinguda de PRINCE MOHAMMAD IBN battery charger, prequalified for Battery Charger as confirming to
la Serra 100 Avenue Barcelona Spain ABDELAZIZ (TAHLIA) Model: 2/DC-500-LP National Grid SA Specification # 46-TMSS-02,
ST. AL AZIZIYH 125 EE635812-7 at with the following conditions:
HEADQUARTERS - Avinguda de la DIST.JEDDAH. FLEX POWER GRID
Serra 100 Avenue Barcelona Spain SULIMANIA BLDG. 2ND LAB (FPGL) KEMA
FLR. RM. 202 NEAR IKEA B.V., WARRANTY:
Barcelona +966 505654978 Klingelbeekseweg Ten (10) years extended warranty/guarantee to
[email protected] 195, Arnhem, The SEC/National Grid SA for the offered Battery
Contact Person - MR. Toni Manzano Netherland, Test Chargers in respect of the defects due to design,
Technical director & Albert Gimenez Report No. manufacturing, installation and workmanship from
Phone - 938482400 & 620970402 2022-028, Date: the date of Provisional Acceptance Certificate
Email ID - [email protected], from 04-12/10/2022 (PAC) of the first turnkey project (in case of
[email protected] and Test Report No. contract award) or from the date of first delivery
Contact Person Email ID - 2022-039 (in case of direct material supply order), as
[email protected], Date:20-21/12/2022 confirmed by the manufacturer, through their
[email protected] Letter Ref. # Nil dated November 04, 2021.
Website - https://www.salicru.com

Total = 17

BATTERIES AND POWER SUPPLIES


18. 3
UPS 5 KVA THRU 100 KVA Applicable Standards: 46-TMSS-03

18. 3 Page 500 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Eram Power Electronics Co. Model: PQ Letter


Saudi Arabia S33100 Based on S&SD letter#18-00008-01-30504401.
dated January 06, 2019, the manufacturer is
3rd Industrial Area, Road No 22, 3rd prequalified for UPS as confirming to SEC
Industrial Area, Dammam 34856 specification # 46-TMSS-03, Rev.0, with the
following conditions:
Dammam
CONDITION:
Contact Person - Jacob All Type, Routine and Special testes shall be
Thomas-Business Unit Manager carried out on the first batch of UPS in an
Phone - +966138404500 Independent Testing Laboratory in the presence
Email ID - [email protected] of three (3) SEC Engineers & one (1) SEC
Contact Person Email ID - approved Independent Inspection Agency (IIA)
[email protected] Inspector. All costs of which shall be borne by
Website - www.apec.sa.com the manufacturer. This was confirmed in writing
by the manufacturer through their letter # #APEC
01/01/01
dated January 01, 2019.

WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #APEC
01/01/02 dated January 01, 2019.

Location has been changed from Al-Khobar to


Dammam:

WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order). as confirmed,
through their letter No. APEC2021010301 dated
03 January 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

18. 3 Page 501 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BORRI S.P.A M/s Abunayyan Trading Type / Model: UPS PQ Letter:


ITALY P.O. box 321, Riyadh S&SD Letter # 14-03226-01-030504401 dated
11411 Rating: , 5 THROUGH 100kVA June 4, 2014, it is pre-qualified for UPS, 5
Plant -Bibbiena(Arezzo) Italy Fax : +966 11 4764684 THROUGH 100kVA.
Website :
Bossir S.P,A Via 8 Marzo. 2-52010 - www.abunayyangroup. CONDITION:
Soci-Bibbiena, Italy com
+966 11 4779111 WARRANTY:
Contact Person - Mr.Paolo como Ten (10) years extended warranty/guarantee in
Phone - +39-0575-5351 respect of defects due to design, manufacture,
Email ID - [email protected] installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through letter # Nil, dated May 23,
2011.

18. 3 Page 502 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BRAGA MORO Itea International Ltd PQ Letter:


ITALY 21st Floor - Tamkeen Type / Model: On Line UPS S&SD Letter 12-03794-01-30504401 dated
Tower, Al Yasmin - November 18, 2012, Braga Moro- Italy is
Plant -Milan , Italy Riyadh 13325 - KSA Rating: pre-qualified for UPS.
Phone: 011 4207555
Via Canzo 4 20068 Peschiera Fax: 011 4655305 CONDITION:
Borromeo, Milano, Milan ,Italy All Type, Routine and Special testes as per
Mr. Nabeel Huda; Mr. National Grid SA Specifications shall be carried
Email ID - Edoardo Lando out on the First unit to be supplied to SEC/National
[email protected]; +966550051979; Grid SA of UPS in an Independent Testing
[email protected].; +966506273359 Laboratory in the presence of three (3)
[email protected] [email protected]; SEC/National Grid SA Engineers & one (1)
Website - http://www.bragamoro.com/ [email protected] SEC/National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by Braga Moro-Italy. This
was confirmed in writing by Braga Moro-Italy
through their letter # SEC Prequalification dated
April 13, 2011.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by Braga Moro- Italy through
their letter # SEC
Preq. dated April 13, 2011.

GUTOR ELECTRONIC LTD.


SWITZERLAND

Website - http://www.gutor.com/

18. 3 Page 503 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JESUS MARIA AGUIRRE SA (JEMA) Rating: UPS up to 100kVA. PQ Letter:


SPAIN S&SD Letter 12-00193-030504001 dated January
17, 2012. It is prequalified for UPS up to 100 kVA.
Lasarte-Oria , Spain
CONDITION:
All Type, Routine and Special testes shall be
carried out on the first batch of each types of
UPS up to 100kVA in an Independent Testing
Laboratory in the presence of three (3) SEC
Engineers & one (1) SEC approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil dated June 17, 2011.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated June
17, 2011.

18. 3 Page 504 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

STATRON AG Type / Model: UPS (S2000 series) PQ Letter:


SWITZERLAND S&SD Letter 12-03254-01-30504401 dated
August 29, 2012, it is pre-qualified for UPS
Plant -Maegenwil (S2000 series).

Industrie Nord Ch-5506, Maegenwil , CONDITION:


Switzerland All Type, Routine and Special testes shall be
carried out on the first batch of each types of
Contact Person - Mr. Marcel Bond UPS in an Independent Testing Laboratory in the
Phone - + 41-62-887-4-887 presence of three (3) SEC Engineers & one (1)
Email ID - [email protected] SEC approved Independent Inspection Agency
(IIA) Inspector. All costs of which shall be borne
by the manufacturer. This was confirmed in
writing by the manufacturer Statron AG through
their letter # bm dated August 13, 2012.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer
Statron AG through their letter # bm dated August
13, 2012.

CEG, BIBIENA PQ Letter:


ITALY TS&SD letter # 09-F001363/02-03032301 dated
2nd May 2009 & S&SD letter #
Website - 14-05308-01-30504401 dated 21st July 2014.
http://www.cegelettronica.com
CONDITION:

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

18. 3 Page 505 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HUAWEI TECHNOLOGIES CO.LTD. Huawei Technologies UPS 2000 & UPS 5000 (A&E) Type tests were PQ Letter
CHINA Investment Saudi Arabia conducted from 12 – Based on S&SD letter # 18-02334-03-30504401
Ltd. Co. 16 February 2017 at dated November 15, 2018, HUAWEI Technologies
Bantian, Longgang District, Shenzhen, Prince Mohammed Bin China Co. Ltd. - China is pre-qualified for Uninterrupted
P. R. China Postal Code : 518129 Abdulaziz Street (Tahliah Telecommunication Power Supply (UPS 2000 & UPS 5000) Used in
St.) Olaya – Riyadh Technology Telecom / Data Centers as conforming to National
Contact Person - Mr. Ryan Liu C-Center. P.O. Box Laboratory (CTTL) in Grid SA specification # 46-TMSS-03, with the
Phone - +966 507981437 295320, Riyadh 11351 Baoding, Beijing, following conditions:
Email ID - [email protected] +966 507981437 China and following
Mr. Ryan Liu; test reports have Warranty
[email protected] been issued vide: Ten (10) years extended warranty/guaranty
1) KEMA from the date of (PAC) of the Turnkey project (In
Inspection Report case of contract award) and from the date of
No. 1127-7 for delivery for the direct material supply order. The
Huawei UPS 5000 guarantee/warranty shall be applicable from first
(A&E), project and shall cover all the cost of material and
2) SGS Inspection labor as per warranty/guarantee of material and
Report No. IN-SUZ- workmanship and will be subsequently reduced
5802-17009 for the yearly in case of future project award. This was
type testing of confirmed in writing by HUAWEI Technologies Co.
Huawei UPS 5000 Ltd. - China through their letter #
(A&E). 18102402-Mrk-SEC/F dated October 25th, 2018.

Total = 8

BATTERIES AND POWER SUPPLIES


18. 4
VALVE REGULATED LEAD ACID (VRLA) STATIONARY BATTERY BANK Applicable Standards: 46-TMSS-04

FIAMM
ITALY

Website -
http://www.fiamm.com/index.aspx

HOPPECKE Cell
GERMANY 260SP.HC2730

Website - http://www.hoppecke.com/.

AEG POWER SOLUTIONS SAS Originally was SAFT Power System SAS-France
FRANCE

18. 4 Page 506 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

C&D
United States

Website - http://www.cdtechno.com/

CHLORIDE (HAWKER CHLORIDE)


United Kingdom

Website -
http://www.chloridepower.com

GNB
United States

HAWKER LTD
United Kingdom

Website - http://www.hawker.co.uk

SAB
GERMANY

Website - http://www.sab.com/

SEC
United States

Website - http://www.sec.gov/

VARTA
GERMANY

Website - http://www.varta.com/

YUASA EXIDE
United States

Website -
http://www.yuasabatteries.com/

Total = 11

18. 4 Page 507 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BATTERIES AND POWER SUPPLIES


18. 5
BATTERY CHARGERS- (Communication Battery Chargers 48 VDC) Applicable Standards: 46-TMSS-05

18. 5 Page 508 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Eram Power Electronics Co. Model L3-48-200 PQ Letter


Saudi Arabia Based on S&SD letter#18-00008-01-30504401.
Rectifier type: Switch mode, Modular dated January 06, 2019, the manufacturer is
3rd Industrial Area, Road No 22, 3rd Type prequalified for 48V DC Communication Battery
Industrial Area, Dammam 34856 Charger Model L3-48-200 as confirming to SEC
Input: specification # 46-TMSS-05, Rev.01, with the
Dammam Voltage: 400VAC, ±10%, 3Ø following conditions:

Contact Person - Jacob Frequency: 60Hz, ±5% CONDITION:


Thomas-Business Unit Manager All Type, Routine and Special testes shall be
Phone - +966138404500 Output: 48VDC carried out on the first batch of 48V DC
Email ID - [email protected] Communication Battery Charger in an
Contact Person Email ID - Independent Testing Laboratory in the presence
[email protected] of three (3) SEC Engineers & one (1) SEC
Website - www.apec.sa.com approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter # #APEC
01/01/01 dated January 01, 2019.

WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #APEC
01/01/02 dated January 01, 2019.

Location has been changed from Al-Khobar to


Dammam:

WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order). as confirmed,
through their letter No. APEC2021010301 dated
03 January 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

18. 5 Page 509 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AEG POWER SOLUTIONS SAS originally was SAFT Power System SAS-France
FRANCE

BENNING D220G48/BWru-TDG SUSPENDED for supply of DC Battery Chargers


FRANCE to SEC/National Grid SA for all ongoing and all
future SEC/National Grid SA projects/purchase
Website - orders based on VP, Engineering letter #
http://www.benning.fr/Anglais/nfrance 18-03214-1-30504401 dated October 08, 2018.
.htm

BRAGA MORO Itea International Ltd Type / Model: BATTERY CHARGER, Prequalified for BATTERY CHARGER, 48 VDC
ITALY 21st Floor - Tamkeen (For Telecom Applications) (For Telecom Applications).
Tower, Al Yasmin -
Plant -Milan , Italy Riyadh 13325 - KSA Rating: 48V DC
Phone: 011 4207555
Via Canzo 4 20068 Peschiera Fax: 011 4655305
Borromeo, Milano, Milan ,Italy
Mr. Nabeel Huda; Mr.
Email ID - Edoardo Lando
[email protected]; +966550051979;
[email protected].; +966506273359
[email protected] [email protected];
Website - http://www.bragamoro.com/ [email protected]

18. 5 Page 510 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ERSKINE Type / Model: Battery Charger PQ Letter:


United Kingdom TS&SD letter# 09-F02210/03-03032301 dated 1st
Rating: 48V DC. . September 2009, ERSKIN System Ltd. (a division
Website - of Dale Power Solution plc) from United
http://www.erskine-systems.co.uk/ Kingdom-Scarborough for 48V DC battery
Charger.

CONDITION:
All type, design, special & routine tests as per
SEC specifications/standards shall be carried out
on the first batch to be supplied to SEC in
securing an order in the manufacturer's
laboratory in the presence of three (3) SEC
engineers & one (1) approved independent
inspection agency Inspector as confirmed by the
manufacturer through their letter no. nil, dt:
05/02/2009.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no. nil, dt: 05/02/2009..

EXIDE Type / Model: SCR TYPE ONLY SCR TYPE ONLY


United States

Website - http://www.exide.com/

18. 5 Page 511 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

STATRON AG Type / Model: Battery Chargers PQ Letter:


SWITZERLAND MPS/BSS S&SD Letter 12-03254-01-30504401 dated
August 29, 2012, it is pre-qualified for Battery
Plant -Maegenwil Rating: 48V DC Chargers 48V DC.

Industrie Nord Ch-5506, Maegenwil , CONDITION:


Switzerland All Type, Routine and Special testes shall be
carried out on the first batch of each types of
Contact Person - Mr. Marcel Bond Battery Chargers 48V DC in an Independent
Phone - + 41-62-887-4-887 Testing Laboratory in the presence of three (3)
Email ID - [email protected] SEC Engineers & one (1) SEC approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer Statron AG through their letter #
bm dated August 13, 2012.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer
Statron AG through their letter # bm dated August
13, 2012.

COM 10 INTERNATIONAL PTY. LTD. Type / Model: SWITCH MODE SWITCH MODE RECTIFIERS / BATTERY
AUSTRALIA RECTIFIERS / BATTERY CHARGERS CHARGERS ONLY FOR TELECOM APPLICATION.
ONLY FOR TELECOM APPLICATION.
Alpha , Australia

Website - http://www.force10.com.au/

18. 5 Page 512 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Chloride S.A.S Project Execution Previously "Emerson Network Power Industrial


FRANCE Development Co. Ltd Systems", the name has been changed again to
(PEDCO) VERTIV Industrial Systems S.A.S based on
Plant -Previously AEES & Emerson 011 4648970, 2312462, VERTIV Industrial Systems S.A.S letter # nil dated
Network Power Industrial System 4169319 29/06/2017.
S.A.S Mr. Ilamettin Canimoglu,
[email protected]
Lyon , France

Lyon

Contact Person - Mr.


Krishnendu.Chakrabarti , Mr.
Jean-Baptiste.Trolle
Contact Person Email ID -
[email protected],
[email protected]
Website - www.VertivCo.com

EMISA (ELECTRO MERCANTIL 2SPE48-50T


INDUSTRIAL S.A. )
SPAIN

Website -
http://www.emisa.es/web/index.asp?l
ang=ing

HAMMER & SIMMONS


United Kingdom

Website -
http://www.harmerandsimmons.com/

T.D.I Type / Model: SWITCH MODE SWITCH MODE RECTIFIERS ONLY FOR TELECOM
United States RECTIFIERS ONLY FOR TELECOM APPLICATIONS
APPLICATIONS
Website - http://www.tdipower.com/

Total = 12

BATTERIES AND POWER SUPPLIES


18. 6
VENTED NICKEL - CADMIUM STATIONARY BATTERY BANK Applicable Standards: 46-TMSS-06

18. 6 Page 513 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EXIDE
United States

Website - http://www.exide.com/

GNB
United States

VARTA Battery cell


GERMANY VHB

Website - http://www.varta.com/

Chloride S.A.S Project Execution Previously "CHOLORIDE ", the name has been
FRANCE Development Co. Ltd changed to Emerson Network Power Industrial
(PEDCO) Systems - France based on Emerson Network
Plant -Previously AEES & Emerson 011 4648970, 2312462, Power Industrial Systems letter # nill dated
Network Power Industrial System 4169319 12/04/2013.
S.A.S Mr. Ilamettin Canimoglu, Then, the name has been changed again to
[email protected] VERTIV Industrial Systems S.A.S based on
Lyon , France VERTIV Industrial Systems S.A.S letter # nill
dated 29/06/2017.
Lyon

Contact Person - Mr.


Krishnendu.Chakrabarti , Mr.
Jean-Baptiste.Trolle
Contact Person Email ID -
[email protected],
[email protected]
Website - www.VertivCo.com

ALCAD
SWEDEN

EMISA
SPAIN

Website -
http://www.emisa.es/web/index.asp
lang=ing

18. 6 Page 514 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FRIWO MERGED WITH SAFT NIFE -SWEDEN


GERMANY

Website - http://www.friwo.de/

GAZ GERATE- UND Type / Model: Ni-cd Battery PQ Letter:


AKKUMULATORENWERK ZWICKAU TS&SD fax ref.#08-F02675/03-03032301 dated
GMBH, ZWICKAU 10/01/2009. Pre-Qualified for Ni-cd Battery.
GERMANY
CONDITION:
Website - http://www.gaz-gmbh.com/ First batch shall be type tested in Independent
Laboratory in presence of (3) SEC engineers &
(1) independent inspector, as confirmed by the
manufacturer through their letter no.nil, dt: 15th
Oct, 2008.

WARRANTY:
Seven (07) years extended warranty/guarantee
in respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.nil, dt: 9th June, 2008..

SAFT AB •Type: SBLE up to 1660AH (updated) Cell Type SBLE have SUSPENDED for all SEC/National Grid SA ongoing
SWEDEN •Type: SBM up to 1390AH been tested for and forthcoming projects based on VP,
•Type: SBH up to 920AH 1660 AH max. at Engineering letter # 20-01984-030504401 dated
Plant -Oskarshamn/ Sweden SAFT AB on Feb. December 02, 2020.
20, 2015. Report No.
Saft Ab, Jungnergatan,P.O. Box 709, REP 0927 Based on S&SD letter # 15-05875-30504401
Se-572 28 Oskarshamn Sweden dated September 17, 2015, the prequalification of
the manufacturer is updated for NICKEL
Contact Person - Mr. Stefhan Nomrén CADMIUM (NiCd) BATTERY .
Email ID -
[email protected] Previously " SAFT-NIFE, Sweden", the name has
Website - been changed to SAFT AB, Sweden, based on
http://www.saftbatteries.com/ SAFT AB Letter #Nil dated January 25, 2016.

Total = 9

18. 6 Page 515 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BATTERIES AND POWER SUPPLIES


18. 7
DC-DC Converter Applicable Standards: 46-TMSS-07

BRAGA MORO Itea International Ltd Type / Model: The type test PQ Letter:
ITALY 21st Floor - Tamkeen MDCCT conducted for Prequalified for DC-DC Converters, 48 Volts
Tower, Al Yasmin - MDCCT BM 48V, 30 based on S&SD Letter 15-11268-01-30504401
Plant -Milan , Italy Riyadh 13325 - KSA A, 1+1 at Tecnolab dated January 13, 2016.
Phone: 011 4207555 in Verbania, Italy
Via Canzo 4 20068 Peschiera Fax: 011 4655305 Rating: 48 Vdc Output from March 24 – 28, WARRANTY:
Borromeo, Milano, Milan ,Italy 2014. Ten (10) years Extended Guarantee / Warranty
Mr. Nabeel Huda; Mr. from the
Email ID - Edoardo Lando date of PAC of first Project (in case of contract
[email protected]; +966550051979; award) or from
[email protected].; +966506273359 the date of delivery for the direct material supply
[email protected] [email protected]; order. This was confirmed, through their Letter #
Website - http://www.bragamoro.com/ [email protected] SEC Preq. dated April 13, 2011.

Total = 1

SUBSTATION INDUSTRIAL LAN DEVICES/EQUIPMENT


19. 1
RUGGEDIZED INDUSTRIAL ETHERNET SWITCH FOR SUBSTATION AUTOMATION SYSTEM Applicable Standards: 47-TMSS-01
(SAS)

19. 1 Page 516 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens Jeddah Siemens Saudi Arabia RUGGEDCOM RST2228 and PQ Letter:


Saudi Arabia Jeddah -Asafan Road RUGGEDCOM RST2228P
fourth Industrial city Based on S&SD letter #MPQ890218820 dated
Plant -Jeddah -Asafan Road fourth (Modon Oasis) February 28, 2023, the manufacturer is
Industrial city (Modon Oasis) +966 55 757 4508 and prequalified for Industrial Ethernet Switch
+966 56 953 1618 RUGGEDCOM type RST2228 and RST2228P as
Jeddah -Asafan Road fourth Industrial Abdoulla.elgazzar@siem confirming to National Grid SA specification
city (Modon Oasis) ens.com #47-TMSS-01 & 47-TMSS-02, with the following
conditions:
Jeddah
Original plant-Siemens Canada and Final
Contact Person - Abdoulla Elgazzar & Assembly at Siemens Jeddah.
Farrukh Hassan
Phone - 012-6618888 Complying the requirements submitted through
Email ID - letter ref # 12012023 / DI PA DCP /RST2228 dated
[email protected], 12.01.2023.
[email protected]
Contact Person Email ID - Fresh Type Test to be conducted for the First
[email protected], Project in Independent accredited laboratory in
[email protected] the presence of three (3) SEC/National Grid SA
Website - Engineers and one (1) SEC/ National Grid SA
https://new.siemens.com/sa/en.html approved 3rd Party Inspector for which the entire
cost shall be borne by Siemens. Fresh Type Test
was confirmed by Siemens through their Letter
#20210610 / PA DCP /TechSupport dated June 15,
2021

WARRANTY:

Ten (10) years extended warranty from the date


of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter #DI/PA/Tech20212028 dated
February 28, 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

19. 1 Page 517 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS CANADA LIMITED RSG 2100, RSG2488 RX1500 for SAS Type test were PQ Lettter:
CANADA witnessed during Based on S&SD letter# 15-07416-030504401
19th to 26th dated October 28, 2015, it is pre-qualified for
I Ia Sc Ci Rc 300 Applewood Crescent Novmebr 2014.Test RUGGEDCOM Ethernet Switches and Routers
Concord On, L4K 5C7 Laboratories Ultra type RSG 2100, RSG 2488, RX 1500 for SAS as
Tech Oakville conforming to National Grid SA specification #
Contact Person - Mr. Mudassar Ahmed Canada and CRiQ 47-TMSS-01, with the following conditions:
Regional Sales Manager Montreal Canada
Phone - +905-856-5288 Letter Report No. WARRANTY:
Email ID - 3629159WT-03& 04 Ten (10) years Extended Warranty shall be
[email protected] applicable for the RUGGEDCOM Ethernet
Website - http://www.siemens.ca Switches and Routers type RSG 2100, RSG
2488, RX 1500 for SAS, to be supplied
toSEC/National Grid SA as confirmed through
Letter # Nil dated 26.08.2014.

BELDEN / HIRSCHMANN AUTOMATION MAR 1030 (MAR 1030, MAR 1032, All the type tests PQ Letter
AND CONTROL GMBH MAR 1130, MAR 1132) / AFS 675 were conducted in Based on S&SD Letter # 16-07249/02-30504401
GERMANY Series Phoenix test lab and dated 28th Nov 2016, it is pre-qualified
MAR 1040 (MAR 1040, MAR 1042, Hirschmann test lab
Plant -Plant Stuttgart, 72654, MAR 1140, MAR 1142) / AFS677 / during 14th April WARRANTY:
Neckartenzlingen, Germany AFR677 Series 2016 to 06th July Ten (10) years warranty shall be applicable for
RSP 35 / AFS 665 / RSP 30 Series 2016. the models of Ethernet Switches and Routers to
Contact Person - Joy Banerji , Vertical RSR 30 / AFS655 Series be supplied to SEC/National Grid SA as confirmed
Account Manager - O&G and Power , through Letter #Nil dated 20.03.2015.. This has
Belden been confirmed in writing by the manufacturer;
Contact Person Email ID - through letter # AIL/BRD/ SEC/PQ/19 dated 22nd
[email protected] May 2010
Website -
http://www.beldensolutions.com/

19. 1 Page 518 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SCHWEITZER ENGINEERING Ahmad Alanezi - Ethernet Switches type SEL 2730M Test conducted at PQ Letter:
LABORATORIES, INC (SEL) Business Development KEMA Laboratories,
United States Manager & Saad Bin Netherlands. Test Based on S&SD letter # 17-04021/02-30504401
Nawaz - Sales Account Report # dated May 28, 2017, SCHWEITZER ENGINEERING
SCHWEITZER ENGINEERING Manager 1172860831, LABORATORIES, INC (SEL), USA is pre-qualified
LABORATORIES, INC 2350 NE Hopkins +996556866625 1172860827, for Ethernet Switches type SEL 2730M as
Court, Pullman, WA 99163 - USA [email protected] 117286O828 conforming to National Grid SA specification #
om 47-TMSS-01 with the following conditions:
Pullman Saad_Bin_nawaz@selin
c.com
Phone - +1.509.332.1890 WARRANTY:
Email ID - [email protected]
Website - www.selinc.com Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter # NIL dated July 16, 2015.

Total = 4

SUBSTATION INDUSTRIAL LAN DEVICES/EQUIPMENT


19. 2
INDUSTRIAL ETHERNET SWITCH FOR ADVANCED METERING INFRASTRUCTURE (AMI) Applicable Standards: 47-TMSS-02

19. 2 Page 519 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens Jeddah Siemens Saudi Arabia RUGGEDCOM RST2228 and PQ Letter:


Saudi Arabia Jeddah -Asafan Road RUGGEDCOM RST2228P
fourth Industrial city Based on S&SD letter #MPQ890218820 dated
Plant -Jeddah -Asafan Road fourth (Modon Oasis) February 28, 2023, the manufacturer is
Industrial city (Modon Oasis) +966 55 757 4508 and prequalified for Industrial Ethernet Switch
+966 56 953 1618 RUGGEDCOM type RST2228 and RST2228P as
Jeddah -Asafan Road fourth Industrial Abdoulla.elgazzar@siem confirming to National Grid SA specification
city (Modon Oasis) ens.com #47-TMSS-01 & 47-TMSS-02, with the following
conditions:
Jeddah
Original plant-Siemens Canada and Final
Contact Person - Abdoulla Elgazzar & Assembly at Siemens Jeddah.
Farrukh Hassan
Phone - 012-6618888 Complying the requirements submitted through
Email ID - letter ref # 12012023 / DI PA DCP /RST2228 dated
[email protected], 12.01.2023.
[email protected]
Contact Person Email ID - Fresh Type Test to be conducted for the First
[email protected], Project in Independent accredited laboratory in
[email protected] the presence of three (3) SEC/National Grid SA
Website - Engineers and one (1) SEC/ National Grid SA
https://new.siemens.com/sa/en.html approved 3rd Party Inspector for which the entire
cost shall be borne by Siemens. Fresh Type Test
was confirmed by Siemens through their Letter
#20210610 / PA DCP /TechSupport dated June 15,
2021

WARRANTY:

Ten (10) years extended warranty from the date


of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter #DI/PA/Tech20212028 dated
February 28, 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

19. 2 Page 520 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS CANADA LIMITED RSG2100 RX1500 for metering System. Type test were PQ Lettter:
CANADA witnessed during Based on S&SD letter# 15-07416-030504401
19th to 26th dated October 28, 2015, it is pre-qualified for
I Ia Sc Ci Rc 300 Applewood Crescent Novmebr 2014.Test RUGGEDCOM Ethernet Switches and Routers
Concord On, L4K 5C7 Laboratories Ultra type RSG 2100, RX 1500 for Metering System as
Tech Oakville conforming to National Grid SA specification #
Contact Person - Mr. Mudassar Ahmed Canada and CRiQ 47-TMSS-02, with the following conditions:
Regional Sales Manager Montreal Canada
Phone - +905-856-5288 Letter Report No. WARRANTY:
Email ID - 3629159WT-03& 04 Ten (10) years Extended Warranty shall be
[email protected] applicable for the RUGGEDCOM Ethernet
Website - http://www.siemens.ca Switches and Routers type RSG 2100, RX 1500
for Metering System, to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 26.08.2014.

BELDEN / HIRSCHMANN AUTOMATION (MAR 1030, MAR 1032, MAR 1130, PQ Letter
AND CONTROL GMBH MAR 1132) / AFS 675 Series) Based on S&SD letter #21-01179-030504401
GERMANY dated November 02, 2021, the manufacturer is
prequalified for INDUSTRIAL ETHERNET SWITCH
Plant -Plant Stuttgart, 72654, FOR ADVANCED METERING INFRASTRUCTURE
Neckartenzlingen, Germany (AMI) as conforming to National Grid SA
specification #47-TMSS-02, with the following
Contact Person - Joy Banerji , Vertical conditions:
Account Manager - O&G and Power ,
Belden WARRANTY
Contact Person Email ID - Ten (10) years extended warranty from the date
[email protected] of PAC of the first turnkey project (in case of
Website - contract award) or date of first delivery (in case
http://www.beldensolutions.com/ of direct material supply order), as confirmed,
through their Letter # Nil dated September 12,
2021 shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

19. 2 Page 521 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SCHWEITZER ENGINEERING Schweitzer Engineering SEL 2730M Test conducted at PQ Letter:


LABORATORIES, INC (SEL) Laboratories Saudi Ltd. KEMA Laboratories, Based on S&SD letter # 20-01356-1-30504401
United States (SEL) Netherlands. Test dated July 26, 2020, SCHWEITZER ENGINEERING
Ahmad Alanezi - Report # LABORATORIES, INC (SEL), USA is pre-qualified
SCHWEITZER ENGINEERING Business Development 1172860831, for INDUSTRIAL ETHERNET SWITCH FOR
LABORATORIES, INC 2350 NE Hopkins Manager 1172860827, ADVANCED METERING INFRASTRUCTURE (AMI)
Court, Pullman, WA 99163 - USA Saad Bin Nawaz - Sales 1172860828 type SEL 2730M as conforming to National Grid
Account Manager SA specification # 47-TMSS-02 with the following
Pullman +996556866625 conditions:
[email protected]
Phone - +1.509.332.1890 om WARRANTY:
Email ID - [email protected] Saad_Bin_nawaz@selin Ten (10) years extended warranty in respect of
Website - www.selinc.com c.com the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter # NIL dated November 16, 2020.

Total = 4

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 1
PILOT WIRE CABLES & Accessories Applicable Standards: 48-TMSS-01,48-TMSS-03,48-TMSS-04,48-TMSS-05

DEMIRER KABLO CABLE & ACCESSORIES


TURKEY

Website -
http://www.masskablo.com/about us
company.asp?md=7

GOLDSTAR CABLE UP TO 100 PAIRS


KOREA, Republic of

KERPENWORK CABLE & ACCESSORIES


GERMANY

20. 1 Page 522 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SAUDI CABLE
Saudi Arabia

Plant -Jeddah, Saudi Arabia

Saudi Cable Company


P.O. BOX 4403 Jeddah 21491
Industrial Area-Jeddah, Saudi Arabia

Fax Number: +966 12 637 9877

Jeddah

Contact Person - Ammar R. Qari


Phone - +966 12 608 7666
Email ID - [email protected] ,
[email protected]
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

RIYADH CABLES
Saudi Arabia

Plant -Riyadh

P.O. Box 26862- Riyadh, 11496 Riyadh


, Saudi Arabia
2nd Industrial City, Al Kharj Road, street
No. 175, 3rd Lane Zone D. Riyadh,
Kingdom of Saudi Arabia

Contact Person - Mr. Dr. Abdulmohsen


Aliheraish – Vice Executive Director;
Mr. Mohammad Al-Shmoury,
Phone - +966 11 2650850 Ext:238 ;
+966 11 2651415
Email ID - [email protected];
[email protected];
[email protected]
Website -
http://www.riyadh-cables.com/

20. 1 Page 523 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS CABLE & ACCESSORIES


GERMANY

Plant -Berlin. Germany

Freyeslebenstr 1 91058 Erlangen

Contact Person - Mr. Yaser Salih


Phone - +49-9131725216
Email ID - [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

STEINER
GERMANY

Website -
http://www.steiner-binoculars.com/ind
ex.html

MIDDLE EAST SPECIALIZED CABLE


(MESC)
Saudi Arabia

Riyadh , Saudi Arabia

Website -
http://www.mesccables.com/

20. 1 Page 524 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JEDDAH CABLE CO.


Saudi Arabia

Plant -jeddah

Po Box 31248 , Jeddah 21497 Jeddah ,


Saudi Arabia

jeddah

Contact Person - Mr. Alaa Dandachi ,


Mohammad Said Minkara
Phone - +966-126360770, 0541462998
Email ID -
[email protected]
Contact Person Email ID -
[email protected]
Website -
http://www.cables.energya.com

LS CABLES Previously LG
SOUTH KOREA

Plant -Gumi/Korea

13 F Ls Tower ,127, Ls-Ro,


Dongan-Gu, Anyang-Si, Gyeonggi-Do,
Korea

Contact Person - Jiyup Baik


Phone - +82-544697602
Email ID - [email protected]
Website - http://www.lscns.com

20. 1 Page 525 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Rating - 500 V Test Date - Aug KTC Korea testing Certification
KOREA, Republic of Co., Ltd. Branch 2011
P. O. Box 300201,
Plant -Dangjin Factory Riyadh 11372, Office No.
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia.
+966 11 410 1773
Contact Person - Jang Hee Lee [email protected]
Phone - +82 2 316 9190
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.taihan.com

Total = 11

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 2
NON METALLIC FIBER OPTIC CABLES Applicable Standards: 48-TMSS-02

ALCATEL
SWEDEN

Website - http://www.alcatel.se/

B.V.TWENTSCHE KABELFABRIEK
NETHERLANDS

Naaksbergen Plant , Netherlands

Website - http://www.tkf.nl/

BICC
United Kingdom

Website -
http://www.generalcable.com/General
Cable/

20. 2 Page 526 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BRUGG TELECOM AG
SWITZERLAND

Website - http://www.brugg.com/

AMWAJ TELECOMMUNICATION Duct type 96 F Jelly filled (SM G. 652D) (Intertek type test PQ Letter:
MANUFACTURING CO. Report No. IR 02 Rev
Saudi Arabia 02 dated Based on S&SD letter#22-01765-30504401 dated
10.10.2022/ UL Type January 04 , 2023 the manufacturer is
Riyadh, Saudi Arabia test Report No. prequalified for NON METALLIC FIBER OPTIC
4790144805-1 Rev CABLE (NMFOC) as confirming to National Grid
E.1 dated SA specification # 48-TMSS-02, with the
31.10.2022 & AICO following conditions:
Letter No.
T/EMWAJ/255-22
dated 16.10.2022 WARRANTY:
for Type Test Report
No. WARRANTY Ten (10) years extended warranty
W-ATF-ATF-078-21 from the date of PAC of the first turnkey project
(Job No. 4/T/2/S) (in case of contract award) or date of first
with date of delivery (in case of direct material supply order),
intervention as confirmed, through their Letter No. NIL dated
25.10.2021 / Amwaj 04/12/2022 shall be applicable for the equipment
Type Test Report No. to be supplied to SEC/National Grid SA.
ATC-NG-FOC-96F-2
1-01 Rev. 01 dated
12.10.2022 )

CORNING CABLES
United Kingdom

Prescot Merseyside , United Kingdom

Website -
http://www.corningcablesystems.com/

FUJIKURA LTD.
JAPAN

Website - http://211.125.78.50/ie e.html

20. 2 Page 527 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FURUKAWA
JAPAN

Website -
http://www.furukawa.co.jp/english/ind
ex.htm

MIDDLE EAST OPTIC FIBER & CABLE 96 F G.652D Duct Type NMFOC Type Tests
MANUFACTURING CO. (MEFC) conducted at UL
Saudi Arabia Abu Dhabi, UAE
(Test Report No.
Riyadh , Saudi Arabia 4789725319-1 dated
31.12.2020)
Website - http://www.mefcf.com/
Type Test Report No.
QC.96 dated
07.01.2021

TUV Rheinland Type


Test Inspection
Report No.
258119318-100
dated 14.01.2021

NKF KABEL B.V,


NETHERLANDS

Website - http://www.nkf.nl/

20. 2 Page 528 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

OMAN FIBER OPTIC CABLE COMPANY PQ Lettter


Oman Based on TS&SD letter# 10-00909-2-03032300
dated April 06, 2010. It is pre-qualified for Non
Rusayl , Oman Metallic Fiber Optic Cable per SEC Specification
48-TMSS-02, with the following conditions:

CONDITION:
The first batch of each type of Non Metallic Fiber
Optic Cable to be supplied to SEC shall be type
tested per relevant International and SEC
Specifications in presence of three (3) SEC
Engineers and one (1) SEC approved IIA
Inspector and all cost pertaining to the test shall
be borne by the Manufacturer as confirmed
through Letter# Nil dated September 12, 2009.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.EU.SEC.PQ.01, dt: 17th June, 2009..

RIYADH TELEPHONE CABLES CO.


Saudi Arabia

Riyadh , Saudi Arabia

SUMITOMO
JAPAN

Yokohama

Website - http://www.sei.co.jp/

20. 2 Page 529 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TE CONNECTIVITY LTD. PQ Lettter


United States Based on S&SD Letter 12-03688-01-30504401
dated January 03, 2012. The name of the
manufacturer has been changed from ADC-
United States to TE Connectivity Ltd.-United
States.

HITACHI
JAPAN

SAUDI CABLE PQ Lettter


Saudi Arabia Based on S&SD Letter 12-03896-30504401 dated
November 10, 2012, SAUDI CABLE Co. - Saudi
Plant -Jeddah, Saudi Arabia Arabia-Jeddah is pre-qualified for Non-Metallic
Fiber Optic Cable (F/O) Cable & Accessories as
Saudi Cable Company conforming to SEC Specification # 48-TMSS-02,
P.O. BOX 4403 Jeddah 21491 with the following condition:
Industrial Area-Jeddah, Saudi Arabia
WARRANTY:
Fax Number: +966 12 637 9877 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Jeddah installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Ammar R. Qari first turnkey project in case of contract award or
Phone - +966 12 608 7666 date of delivery in case of direct material supply
Email ID - [email protected] , order, as confirmed by the manufacturer thru
[email protected] letter #nil, dt: June 12, 2011.
Contact Person Email ID -
[email protected]
Website - www.saudicable.com

LS PREVIOUSLY LG
SOUTH KOREA

Website - http://www.lscable.com/

20. 2 Page 530 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RIYADH CABLES 96 F G.652D/G.655 Direct Buried Type Tests PQ Letter


Saudi Arabia 96 F G.652D Duct Type conducted in UL Abu Based on S&SD letter # 21-00651-30504401
Dhabi & Riyadh dated May 23, 2021, the manufacturer is
Plant -Riyadh Cable Lab as follow: prequalified for NON METALLIC FIBER OPTIC
CABLES as confirming to National Grid SA
P.O. Box 26862- Riyadh, 11496 Riyadh SM 96F G.652D- DB specification # 48-TMSS-02 with the following
, Saudi Arabia (Direct Buried), conditions:
2nd Industrial City, Al Kharj Road, street Report #
No. 175, 3rd Lane Zone D. Riyadh, 4789721350-1, R2, WARRANTY
Kingdom of Saudi Arabia Testing Dates: Ten (10) years extended warranty from the date
12-12-2020 to of PAC of the first turnkey project (in case of
Contact Person - Mr. Dr. Abdulmohsen 10-02-2021 and contract award) or date of first delivery (in case
Aliheraish – Vice Executive Director; date of issue: of direct material supply order), as confirmed,
Mr. Mohammad Al-Shmoury, 01-3-2021. through their Letter No. C21R-05-0076-F dated 19
Phone - +966 11 2650850 Ext:238 ; May, 2021 shall be applicable for the equipment
+966 11 2651415 SM 96F G.655- DB to be supplied to SEC/National Grid SA.
Email ID - [email protected]; (Direct Buried),
[email protected]; Report #
[email protected] 4789721350-2, R2,
Website - Testing Dates:
http://www.riyadh-cables.com/ 09-12-2020 to
10-02-2021 and
date of issue:
01-3-2021.

SM 96F G.652D-
Duct Type, Report #
4789721350-3, R2,
Testing Dates:
14-12-2020 to
10-02-2021 and
date of issue:
01-3-2021.

Third Party
Independent
Inspector Intertek
Report # IR03Rev03
dated: 16-02-2021.

20. 2 Page 531 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS
GERMANY

Plant -Berlin. Germany

Freyeslebenstr 1 91058 Erlangen

Contact Person - Mr. Yaser Salih


Phone - +49-9131725216
Email ID - [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

MIDDLE EAST SPECIALIZED CABLE


(MESC)
Saudi Arabia

Riyadh , Saudi Arabia

Website -
http://www.mesccables.com/

PIRELLI
ITALY

AFL TELECOMMUNICATIONS EUROPE PREVIOUSLY ALCOA FUJIKURA LTD. (AFL)


LTD
United Kingdom

Website - http://www.afltele.com/

DRAKA NK
FINLAND

Website - http://www.draka.com/

20. 2 Page 532 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PRYSMIAN TELECOM Zamil Group Holding co, Model: Test Performed at PREVIOUSLY "PIRELLI"
SPAIN Commerical Div Kinectrics Canada in
6728, 48 Cores , May, 2014
Plant -Vilanova I La Geltru/Spain Report#
K-419533-RC-0003-
Ctra. C-15,Km, 2-P.I. Masia D’En Notari R01
08800 Vilanova I La Geltru ( Spain)

Contact Person - Mr. Toni Nieto


Phone - +34608749306
Email ID -
[email protected]
Website -
http://www.prysmiangroup.com

Total = 24

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 4
MEDIUM DENSITY FIBER OPTICS SYSTEM-FIBER OPTIC COMMUNICATION TERMINAL Applicable Standards: 48-TMSS-06
EQUIPMENT
ABB-Ludvika
SWEDEN

Plant -Sweden

Ludvika, Sweden

Contact Person - Mr. Magnus


Johansson
Phone - +46 240 783228
Email ID -
[email protected]
Website - http://www.abb.se/

PHILIPS
NETHERLANDS

Website -
http://www.philips.nl/index.page

20. 4 Page 533 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LOOP TELECOMMUNICATION Access DCS-Mux Type DXC (from PQ Lettter


INTERNATIONAL Loop Family - AM3440) Based on S&SD letter# 14-08552-01-30504401
Taiwan dated December 12, 2014 and S&SD letter #
Digital Cross Connect Equipment type 15-01248-01-30504401 dated February 19, 2015,
Taiwan-Hsinchu eDXC (from Loop family-O9500) it is pre-qualified for Access DCS-Mux Type DXC
(from Loop Family-AM3440) and Digital Cross
Connect Equipment type eDXC (from Loop
family-O9500), as conforming to National Grid SA
specification # 48-TMSS-06, with the following
condition:

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt:mar 15, 2013.

TELETTRA
FRANCE

AT & T (LUCENT TECHNOLOGIES)


United States

20. 4 Page 534 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DEDICATED NETWORK PARTNERS PQ Lettter


(DNWP) Based on S&SD letter# 15-08552-01-30504401
FINLAND dated March 18, 2015, Dedicated Network
Partners (DNWP) Oy (Espoo/Helsinki-Finland) is
OY Helsinki Finland pre-qualified for designing, marketing, servicing
of Connection Master - which is manufactured
and tested under license of DNWP by Sanmina
Corp (Oulu/Haukipudas-Finland) - conforming to
National Grid SA specification # 48-TMSS-06,
with the following condition:

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Nil dated June 18, 2014.

FUJITSU
JAPAN

GE INDUSTRIAL SYSTEM ONTARIO PQ Letter


CANADA Based on TADD letter# 09-0297-030225 dated
28th March 2009; (Note: GE Industrial System,
Ontario, Canada Canada has bought only the Lentronics business
from Nortel, Canada that manufactures TN1U
SHD Fiber Optic Terminal Equipment and MUX)

NORTEL
CANADA

Website - http://www.nortel.com/

ALCATEL
FRANCE

Website - http://www.alcatel.fr/

20. 4 Page 535 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Switzerland Ltd. Hitachi Energy FOX515 Access Multiplexer KEMA Inspection Mfr. Name change from ABB Switzerland Ltd. to
SWITZERLAND Hitachi Energy Ltd. Report reference Hitachi Energy Switzerland Ltd.
Riyadh, Saudi Arabia No. 1119-17
Plant -switzerland Based on TADD letter# 09-0576-030225 dated
FOX615 Access Multiplexer (With June 10, 2009, SCADA letter# SOCW/ DIV/97 and
Bruggerstrasse 72, 5400 Baden OPIC1 Card) Telecommunication Dep. letter#
09-136-03040001. ABB, Switzerland is
Baden pre-qualified for FOX515 Access Multiplexer.

Contact Person - Mr. Ahmed Abubasha,


Mr. Abdulmajeed Alothman, Mr. Michal Based on S&SD letter # 17-04894-01-30504401
Adamski , Mr. Mohammed Ilyas dated July 18, 2017, ABB, Switzerland is
Phone - +41 58 588 33 50,+41 58 585 pre-qualified for FOX615 Access Multiplexer
77 44 (With OPIC1 Card) as conforming to National Grid
Email ID - SA specification # 48-TMSS-06, with the
communication.networks@hitachienerg following conditions:
y.com
Contact Person Email ID - WARRANTY:
[email protected] •Ten (10) years extended warranty/Guarantee
om from the date of PAC as confirmed; through their
,[email protected] Letter No. 16-05762-01-030504401 dated
Website - www.hitachienergy.com 27/07/2016 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.

Total = 11

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 5
MEDIUM DENSITY FIBER OPTICS SYSTEM (FIBER OPTIC LOW DENSITY EQPT.) Applicable Standards: 48-TMSS-06

20. 5 Page 536 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Huawei Technologies Co., Ltd. Huawei Tech. Investment OSN 550 Huawei GCTC PQ Letter
CHINA Saudi Arabia Co,. LTD. OSN 580 (Global Compliance Based on S&SD letter# MPQ # 35489820 dated
Huawei Technologies Testing Center) May 28, 2019, the manufacturer is prequalified
Plant -Sonshan, Dongguan Investment Saudi Arabia Model E6600 series ( E6608, E6608T, Address NO.2 New for MEDIUM DENSITY FIBER OPTICS SYSTEM
Ltd. Co. E6616) City Avenue Song (FIBER OPTIC LOW DENSITY Equipment) as
Huawei - Song Shan Hu Technology Prince Mohammed Bin Shan Lake Sci. confirming to National Grid SA specification #
IndustrialPark NA dongguan China PRC Abdulaziz Street (Tahliah &Tech. Industry 48-TMSS-06, with the following conditions:
St.) Olaya – Riyadh Park, Dongguan,
Contact Person - Liu Yong C-Center. P.O. Box Guangdong, P.R.C. WARRANTY
Phone - 0507981437 295320, Riyadh 11351 Test Date Ten (10) years extended warranty from the date
Email ID - [email protected] +966 507981437 03.04.2019 – of PAC of the first turnkey project (in case of
Website - huawei.com [email protected] 11.04.2019 contract award) or from date of first delivery (in
case of direct material supply order), as
confirmed, vide Huawei Letter No. Nil dated
01/08/2018 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.

WARRANTY
Ten (10) years extended warranty/guarantee for
the offered DVM Model OSN 580 in respect of
defects due to design, manufacture, installation &
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project in case of contract award or date of
delivery in case of direct material supply order,
as confirmed vide Huawei Technologies Co., Ltd.
letter No. NIL Dated 01 August 2018

PQ Letter:
Based on S&SD letter #22-00370-30504401
dated March 23, 2022 the manufacturer is
prequalified for MEDIUM DENSITY FIBER OPTICS
SYSTEM (FIBER OPTIC LOW DENSITY EQPT.), as
conforming to National Grid SA specification
#48-TMSS-06, with the following conditions:

WARRANTY:
Ten (10) years Extended Warranty as confirmed
through Letter #Nil dated 19/05/2021 shall be
applicable for all supplies to the Company by
Huawei Technologies Co., Ltd. - China

20. 5 Page 537 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB INFOCOM LTD.


FRANCE

Turgi , France

Website - http://www.abb.fr/

LICOM
United States

Website - http://www.licom.net/

PRISM
CANADA

SIEMENS
GERMANY

Plant -Berlin. Germany

Freyeslebenstr 1 91058 Erlangen

Contact Person - Mr. Yaser Salih


Phone - +49-9131725216
Email ID - [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

Total = 5

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 6
Active & Passive Shelters for Telecommunication Facilities Applicable Standards: 48-TMSS-07

20. 6 Page 538 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RAWABI ELECTRIC COMPANY Previously was "RAWABI SPECIALIZED


Saudi Arabia ENCLOSURES"

Plant -Al Khobar - KSA PQ Letter


Based on S&SD letter # 17-00822-1-30504401
Al Khobar dated March 30, 2017, Rawabi Specialized
Enclosures - Al-Khobar, KSA is pre-qualified for
Contact Person - Mohammed Alsaihati , Active Telecommunication Shelters as conforming
Fawzi Al-Alwan & Fahad A. Othman to National Grid SA specification # 48-TMSS-07
Phone - +966138123282 rev.0, with the following conditions:
Contact Person Email ID -
[email protected] WARRANTY:
m , [email protected] & Ten (10) years extended warranty from the date
[email protected] of PAC of the first turnkey project (in case of
Website - www.rse.com.sa contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their letter # Nil, dated March 14, 2016
shall be applicable for all Active
Telecommunication Shelters to be supplied to
SEC/National Grid SA.

Refrigerated Containers Industrial Co. Type Tests PQ Letter


(REFCON) conducted in Based on S&SD letter # MPQ132319320 dated
Saudi Arabia Refrigerated October 07, 2019, the manufacturer is
Containers Industrial prequalified for Active And Passive Telecom
Plant -Al Kharj Co. (REFCON)- Shelters as confirming to National Grid SA
Al-Kharj, Saudi specification # 48-TMSS-07, with the following
New Industrial City, Industrial City Gate Arabia during 26-27 conditions:
2 , Street 59 June 2019
WARRANTY
Contact Person - Eng. Essam Allari Ten (10) years extended warranty from the date
Phone - +966 11 2659460 , 61 , 62 of PAC of the first turnkey project (in case of
Email ID - [email protected] contract award) or date of first delivery (in case
Contact Person Email ID - of direct material supply order), as confirmed,
[email protected] through their Letter No. Nil dated September 25,
Website - alinco.com.sa 2017 shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

Total = 2

20. 6 Page 539 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 7
OTN-DWDM (OPTICAL TRANSPORT NETWORK DENSE WAVELENGTH DIVISION Applicable Standards: 48-TMSS-08
MULTIPLEXING EQUIPMENT FOR BACKBONE NETWORK)
ZTE Corporation Landis + Gyr AG- ZXONE 9700 ZTE Corporation - PQ letter:
CHINA Greece China has Based on S&SD letter # MPQ 11819920-classI(a)
3rd floor, Tawaren successfully -2016-class I(b) dated November 08, 2017, ZTE
Plant -LiuXian Rd Xili Shenzhen China Center Building King completed the type Corporation - China is pre-qualified for DWDM as
PRC Fahad Road tests of DWDM conforming to latest National Grid SA
P.O.BOX#58970 Riyadh, Equipment at China specification # 48-TMSS-08
LiuXian Rd Xili Shenzhen China PRC Saudi Arabia Telecommunication
+966 539467479 Technology Labs WARRANTY:
Shenzhen [email protected] (CTTL). Bearing • Ten (10) years extended warranty/guarantee in
.cn report # B17X60154 respect of defects due to design, manufacture,
Contact Person - Eng. Fox Yang & B17X20741 during installation and workmanship from the date of
Phone - +966 539467479 August 14-26, 2017 Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected]; in the presence of first turnkey project in case of contract award or
[email protected]; SEC/National Grid date of first delivery in case of direct material
[email protected] SA Engineers and supply order, as confirmed by the manufacturer
Contact Person Email ID - SGS inspector vide letter # ZTE-20170402-SECDWDM-01, dated
[email protected] bearing report March 03, 2017.
Website - www.landisgyr.com #IN-SZ-5802-17082-
1&
IN-SZ-5802-17082-2
.

20. 7 Page 540 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NIPPON ELECTRIC CO. LTD (NEC) Type DW • NEC Corporation Based on S&SD letter # 16-04313-30504401
JAPAN 7000, (Japan) has dated May 30, 2016, NEC Corporation - Japan is
successfully pre-qualified for supply, installation and
Plant -. completed the type configuration of DWDM Equipment, as conforming
tests of DWDM to National Grid SA specifications # 48-TMSS-08
Aza-Raijin Yoshioka Daiwa-Cho Equipment at NEC with the following condition:
Kurokawa Miyagi 981-3681 Japan laboratory during
23rd of February to • Ten (10) years Extended Guarantee as agreed
Miyagi 4th of March, 2016 and confirmed by NEC Corporation (Japan)
in the presence of through their letter Ref. EMEA-ME2 dated 16th
Contact Person - Mr. Nemat Ullah Khan SEC/National Grid May 2016 shall be applicable for all supplies of
. Assistant General Manager , Mr. SA Engineers and DWDM Equipment Type DW 7000 made to the
Yoshikazu Matsushima Intertek inspector Company by NEC Corporation (Japan).
Contact Person Email ID - bearing Test Report
[email protected]. #
,[email protected] CVNWD-M15-0806,
issue 01 dated:
March 04, 2016 was
issued by Intertek
Industry Services
Japan Limited,
signed by 03
SEC/National Grid
SA Engineers.

20. 7 Page 541 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Flextronics Manufacturing Srl Nokia Arabia Limited Type 1830 PSS-32 Type tested during PREVIOUSLY Alcatel-Lucent
ITALY Abdullah AlDulaigan 20th -31st October
Riyadh 2014 and 4, 27-28 PQ Lettter
Via di Monte d’Oro, 14 CAP 34148 +966 55 4000 780 Nov, 2014. Based on S&SD letter # 15-0010-02-30504401
Trieste Abdullah.Aldulaigan@No dated 12th February 2015, the manufacturer is
kia.com Test Report Nos: prequalified for OTN-DWDM equipment Type 1830
Contact Person - Mr. Eric Saniard, 80SO00094, PSS-32 as conforming to National Grid SA
Account Sale Manager 80SO00096, CSi specification # 48-TMSS-08, Rev.0 with the
Email ID - Test Report following condition:
[email protected] No.0118/ME/CMP/14
Rev.2, WARRANTY
Centrotecnica SRL Ten (10) years extended warranty/guarantee in
report No. respect of defects due to design, manufacture,
VR1400223IMRK.do installation & workmanship from the date of
c. Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: 6th june, 2014.

20. 7 Page 542 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HUAWEI TECHNOLOGIES CO.LTD. Huawei Technologies Optix OSN 8800 Type tests were PQ Letter:
CHINA Investment Saudi Arabia OptiX OSN 9800 series (OSN 9800 conducted from 20 Based on S&SD letter # 18-07410-03-30504401
Ltd. Co. M12, OSN 9800 M24, OSN 9800 M05 to 29 January 2016 dated November 15, 2018, & S&SD letter
Bantian, Longgang District, Shenzhen, Prince Mohammed Bin and OSN 9800 Universal Platform at Huawei #21-00071/01-030504401 dated February 16,
P. R. China Postal Code : 518129 Abdulaziz Street (Tahliah Sub-rack) Technologies Co. Ltd 2021, HUAWEI Technologies Co. Ltd. - China is
St.) Olaya – Riyadh at Shenzhen, China pre-qualified for OTN-DWDM Equipment as
Contact Person - Mr. Ryan Liu C-Center. P.O. Box and from 21 – 22 conforming to National Grid SA specification #
Phone - +966 507981437 295320, Riyadh 11351 November 2016 at 48-TMSS-08, with the following conditions:
Email ID - [email protected] +966 507981437 Mr. China
Ryan Liu Telecommunication Warranty:
[email protected] Technology Ten (10) years extended warranty/guaranty
Laboratory (CTTL) in from the date of (PAC) of the Turnkey project (In
Baoding, China. The case of contract award) and from the date of
following test delivery for the direct material supply order. The
reports have been guaranty/warranty shall be applicable from first
issued vide: project and shall cover all the cost of material and
KEMA Inspection labor as per warranty/guaranty of material and
Report No. DNV- GL workmanship and will be subsequently reduced
1067-16 for Huawei yearly in case of future project award. This has
OTN-DWDM been confirmed in writing by HUAWEI
Equipment and Technologies Co. Ltd. - China through their letter
SGS Inspection Ref. 18102408-Mrk-SEC/F dated October 25,
Report No. 2018 & Letter # AJC/PQ-GW dated 31 December
IN-SUZ-5802-16066 2020.
for the type testing
of Huawei
OTN-DWDM
Equipment.

Total = 4

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 8
SYNCHRONOUS DIGITAL HIERARCHY (SDH) EQUIPMENT Applicable Standards: 48-TMSS-09

NIPPON ELECTRIC CO. LTD


JAPAN

Japan-Tokyo

20. 8 Page 543 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALCATEL-LUCENT PQ Lettter
CHINA Based on S&SD letter # 14-07395-30504401,
dated 23/10/2014, the test facility of Alcatel
Shanghai China Lucent in (Bydgoszcz, Poland) is allowed to
conduct Factory Routine test and Integration
testing of communication equipment
manufactured in Alcatel-Lucent Factory in
Shanghai China confirming to National Grid SA
requirements.

CONDITION
Based on TS&SD letter #10-03519/03-03032301
dated 17/04/2011, it is pre-qualified for Fiber
Optic Communication Terminal type
Optenix1660SM with the following conditions:

The first batch of each type of Optenix 1660SM


to be supplied to SEC shall be Type/Special &
Routine/Sample tested in an independent testing
laboratory in the presence of three (3) SEC
engineers & one (1) SEC approved independent
inspection agency Inspector and all cost
pertaining to the tests shall be borne by
Manufacturer. This was confirmed in writing by
the Alcatel-Lucent (ASB)-China through letter #
ALU/172/SI/2010 dated 12/12/2010.

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # ALU/172/SI/2010 dated 12/12/2010.

Alcatel-lucent (ASB)-China has confirmed that


after the successful resolution of the
prequalification process, configuration as well as
the drawings and details of the Trial Link to be
installed in SEC Network shall be submitted for

20. 8 Page 544 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SEC review and approval. The places and dates


of Trail Link installation will be sent to the
manufacturer.
-----------------------------------------------------------
----------- PQ Lettter

Based on TS&SD letter # 11-03458/02-03032301


dt 03/12/2011, it's prequalified for Fiber Optics
Terminal Equipment 1511MAX Series conforming
to SEC Specification # 48-TMSS-06 Rev.0 with
the following conditions:

CONDITION
Type, Special, sample & routine tests shall be
conducted on the first batch of 1511MAX Series
to be supplied to SEC, in the presence of three
(3) SEC Engineers & one (1) SEC approved
independent inspection agency Inspector in an
independent testing laboratory. All the related
costs for witnessing the tests will be borne by
the manufacturer. This was confirmed by Alcatel
Lucent (ASB) Shanghai China through response
letter # ALU/25/SI/2011 dated 30/01/2011 and
letter # Nil dated 27/04/2011.

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: 30/01/2011.

Alcatel-lucent (ASB)-China has confirmed that


after the successful resolution of the
prequalification process, configuration as well as
the drawings and details of the Trial Link to be
installed in SEC Network shall be submitted for
SEC review& approval. The places and dates of
Trail Link installation will be sent to the

20. 8 Page 545 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

manufacturer.

HUAWEI TECHNOLOGIES CO.LTD. OSNSeries:1500,2500,3500,7500,9500 PQ Lettter


CHINA and iManager T2000NMS Based on TS&SD Letter # 10
F01736/02-03032301 dt 18/08/2010 & S&SD
Bantian, Longgang District, Shenzhen, Letter # 14-06894-01-30504401 dated
P. R. China Postal Code : 518129 22/10/2014, it is prequalified for
OSNSeries:1500,2500, 3500,7500,9500 and
Contact Person - Mr. Ryan Liu iManager T2000NMS, with the following
Phone - +966 507981437 conditions:
Email ID - [email protected]
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # 70917174/MRK/SEC dated19/02/2008G.

CORIANT GMBH Previously Nokia Solutions and Network BV


GERMANY (NSN), Based on S&SD Letter
#15-02455-1-30504401 dated 15 June 2015,
St. Martin Str. 76 81541 Munich Name of the manufacturer has been changed
Germany from NSN siemens Germany to Coriant Berlin
Germany
Contact Person - Mr. Olaf Horsthemke
Managing Director - Approved for SDH equipment (hiT 7080, hiT
Phone - +49-89-540215006 7070, hiT 7065,
Email ID - hiT 7060, hiT 7035 and TNMS)
[email protected]

Total = 4

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 10
FIBER OPTIC INTERCONNECTING DEVICES & PASSIVE COMPONENTS Applicable Standards: 48-TMSS-12

NOKIA OPGW Joint Box


FINLAND

Website - http://www.nokia.com/

20. 10 Page 546 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AMWAJ TELECOMMUNICATION Type tested in UL PQ Letter


MANUFACTURING CO. India Based on S&SD letter # 15-00581-02-30504401
Saudi Arabia dated April 21, 2015 it is pre-qualified for
Telecommunication & Fiber Optic Passive
Riyadh, Saudi Arabia Products (Frame, Box, Rack, joint closure etc.)
with the following condition:

WARRANTY:
Seven (7) years extended warranty from the
date of PAC of the turnkey project in case of
contract award or date of delivery in case of
direct material supply order. This was confirmed
by Amwaj Telecom MFG. Co. letter dated
09/06/2010.

CORNING CABLES OFMR, FSTP and Optical accessories


United Kingdom

Prescot Merseyside , United Kingdom

Website -
http://www.corningcablesystems.com/

ERICSON OFMR and FSTP


SWEDEN

Website - http://www.ericson.com/

20. 10 Page 547 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

OPTOKON Tarasol Technology for 1. OFMR for Telecom 450 mm x 900 mm PQ Lettter
CZECH REPUBLIC Telecom & IT x 2200 mm OFMR for SAS 800 mm x Based on TS&SD letter# 06-F208-03032300
Bashar Mohammad 800 mm x 2200mm OFMR 16U dated Feb 21, 2006, it is prequalified only for the
Jihlava , Czech Republic Nawar Said specified accessories
+966 11 4765284; +966 2. Rack Mount Fiber Optic Patch
Website - http://www.optokon.cz/ 503522458 Panel/FSTP type MCNP & MFDC (TMVJ
[email protected] & OFDU) consisting of 12/24/36/48/96
m; ports.
[email protected]
3. Fiber Optic Wall Mount Box type of
MPIC consisting of 12/24/36/48/96
ports

4. Fiber Storage Shelf type MFSS

5. Optical Pig Tails/Patch cords,


equipped with LC/APC, LC/PC, FC/PC &
E2000 connectors.

Note: All the FO interconnecting and


Devices and Passive components shall
comply to 48-TMSS-12, Rev.01.

R & M REICHLE & DE-MASSARI AG PQ Lettter


SWITZERLAND Based on S&SD Letter 13-02127-030504401
dated May 19, 2013, R & M Reichle & De-Massari
Wetzikon , Switzerland AG, Wetzikon, Switzerland is pre-qualified for
"Accessories only" fiber optic and copper
Website - passive components (Structure Cabling) with the
http://www.qualitrolcorp.com/ following conditions:

WARRANTY:
Five (5) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Nil, dt: June 10, 2013.

20. 10 Page 548 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TE CONNECTIVITY LTD. OFMR, FSTP and Optical accessories PQ Lettter


United States Based on S&SD Letter 12-03688-01-30504401
dated January 03, 2012. The name of the
manufacturer has been changed from ADCUnited
States to TE Connectivity Ltd.-United
States.

TELECT PQ Lettter
Poland Based on TS&SD letter# 09-01095-03032301
dated 18th. April 2009 for the following
Wroclaw , Poland accessories:
- Management Rack E-9000 series
- Distribution & Termination Unit LCX.
- Wall mounted unit LanLinxs.

INDUSTRIAS ARRUTI
SPAIN

Website -
http://www.grupoarruti.com/empresa.a
sp

AFL TELECOMMUNICATIONS GMBH OPGW Joint Box Previously Draka Comteq Germany GmbH & KG.
GERMANY
WARRANTY:
Monchengladbach , Germany Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.

20. 10 Page 549 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PRYSMIAN TELECOM OPGW/NMFOC Joint Box, PREVIOUSLY "PIRELLI"


SPAIN Accessories (pigtails, Patch cords)

Plant -Vilanova I La Geltru/Spain

Ctra. C-15,Km, 2-P.I. Masia D’En Notari


08800 Vilanova I La Geltru ( Spain)

Contact Person - Mr. Toni Nieto


Phone - +34608749306
Email ID -
[email protected]
Website -
http://www.prysmiangroup.com

JIANGSU ZHONGTIAN TECHNOLOGY OPGW Joint Box, Type ST up to 192 Tests performed at: PQ Letter
CO.LTD (ZTT) splices China Based on S&SD Letter # 17-02628-01-30504401
CHINA Telecommunication dated May 09, 2017it is prequalified with the
Technology Labs following condition:
Chinanantong, China (January 09-13,
2017) WARRANTY:
Report # B17X70084 Ten (10) years extended warranty from the date
of PAC of the first turnkey in case of contract
award or date of first delivery in case of direct
material supply order as confirmed through ZTT
letter # ZTT-G-2016-06-10-01 dated 10/6/2016.

Total = 12

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 11
DIGITAL PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) & ACCESSORIES Applicable Standards: 48-TMSS-16

ALCATEL NV
FRANCE

Plant -Paris ,France

MITEL CORP.
CANADA

Website - http://www.mitel.com/

20. 11 Page 550 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NORTHERN TELECOM
CANADA

Website -
http://www.northerntelecom.com/

PHILIPS
NETHERLANDS

Website -
http://www.philips.nl/index.page

RAYCHEM
United States

United States-Ca

NORTEL
CANADA

Website - http://www.nortel.com/

ERICSON
SWEDEN

Website - http://www.ericson.com/

SIEMENS
GERMANY

Plant -Berlin. Germany

Freyeslebenstr 1 91058 Erlangen

Contact Person - Mr. Yaser Salih


Phone - +49-9131725216
Email ID - [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

20. 11 Page 551 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AT & T
United States

New York , United States

Website - http://www.att.com/

ALCATEL
FRANCE

Website - http://www.alcatel.fr/

Total = 10

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 12
TELEPROTECTION SYSTEM Applicable Standards: 48-TMSS-17

ISKRA Sistemi Adnan Omar Mohammed ISKARA Laboratory PQ Letter


Slovenia Sabban Const. Est. and SIQ Slovenia •Based on S&SD letter # 16-10655-30504401
Jeddah - K.S.A Laboratory Test dated January 19, 2017, the manufacturer ISKRA
Plant -Ljubljana - SLOVENIA Mr. Zakaria Buhaisi, 012 report no. Sistemi - Slovenia is pre-qualified for DZ9
662 9446 T251-1036/16 Tele-protection equipment as conforming to
ISKARA Sistemi d.d Zakaria National Grid SA specification # 48-TMSS-17
Stegne 21, 1000 Ljubljana, SLOVENIA [email protected] rev.0, with the following conditions:

Ljubljana WARRANTY
•Ten (10) years extended warranty in respect of
the defects due to manufacturing and
workmanship, from the date of PAC of the first
turnkey project (in case of contract award) or
date of first delivery (in case of direct material
supply order), as confirmed through their Letter
No. DTE349/14-KIP dated September 05,2014
shall be applicable.

20. 12 Page 552 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ZIV APLICACIONES Y TECNOLOGIA Innovative Systems Co. TPU-1 Note:


S.L. SOCIEDAD UNIPERSONAL Ltd. (ISys) Previously " DIMAT", the name has been changed
SPAIN Riyadh, Saudi Arabia to "
+966 11 460 8160 ZIV APLICACIONES Y TECNOLOGIA S.L.
Antonio Machado, 78-80 [email protected] SOCIEDAD UNIPERSONAL". based on their letter
Viladecans Business Park # KM28031811 dated March 28,
Edificio Australia - Planta Baja 2018.
08840, Viladecans

BARCELONA PQ Lettter
Based on TS&SD Letters# 09-01439-2-03032301
Contact Person - Marco Sensei dated 7th July 2009 & 10-00845-1-03032301
Phone - +34 944 522 003 dated April 04, 2010. It is pre- qualified for
Email ID - Tele-protection Equipment type TPU-1 with the
[email protected] following conditions:
Contact Person Email ID -
[email protected] WARRANTY
Website - www.zivautomation.com Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

SIEMENS
GERMANY

Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany

Phone - +49 (911) 433 8321


Website -
www.siemens.com/ingenuityforlife

20. 12 Page 553 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GE/ALSTOM POWER CONVERSION Branch of COGELEX DIP5000 Previously Areva, the name has been changed to
FRANCE Alkhobar, GE/ Alstom power conversation
[email protected]
Plant -Ludres 0096638579071
[email protected]
418 Rue Denis Papin
54712 Ludres Cedex

Contact Person - Nathalie souchet


Phone - +33 3 83265316
Email ID - [email protected]
Contact Person Email ID -
[email protected]
Website - www.ge.com

Hitachi Energy Switzerland Ltd. Hitachi Energy Ltd NSD570 Name has changed from ABB Switzerland to
SWITZERLAND Riyadh, Saudi Arabia Hitachi Energy Switzerland Ltd
+966 11 2181703 Mobile:
Plant -switzerland +966 500414555

Bruggerstrasse 72, 5400 Baden

Baden

Contact Person - Mr. Ahmed Abubasha,


Mr. Abdulmajeed Alothman, Mr. Michal
Adamski , Mr. Mohammed Ilyas
Phone - +41 58 588 33 50,+41 58 585
77 44
Email ID -
communication.networks@hitachienerg
y.com
Contact Person Email ID -
[email protected]
om
,[email protected]
Website - www.hitachienergy.com

Total = 5

20. 12 Page 554 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 13
Telecom Cabinets and Racks Applicable Standards: 48-TMSS-13

SYSTEM HOUSE FACTORY FOR Muhannad Alshehri Telecom cabinet 19’’ modular & ETSI TÜV Rheinland PQ Letter
ELECTRIC PANELS (SEP,) +966 11 498 0822 Rack ; 2200 x 800 x 600 mm (H x W x Arabia LLC, Report
Saudi Arabia [email protected] D). # 258129578-100, Based on S&SD letter #MPQ 991218720 dated
dated 19th January, May 03, 2023, the manufacturer System House
Plant -New Industrial Area No:1, Riyadh Type Test conducted Factory for Electric Panels(SEP) Riyadh, KSA is
on 2023 19th prequalified for Telecom Cabinets and Racks as
P O Box 355950, New Industrial Area September, 2022 confirming to National Grid SA specification #
No:2, Riyadh -11383 and 10th January, 48-TMSS-13, with the following conditions:
2023, at King Saud
Contact Person - Mr. Bruno Stocchi, University HV
Muhannad Alshehri Laboratory, Riyadh WARRANTY
Phone - +966- 0535754302 , +966-
0505278491 Ten (10) years extended warranty from the date
Email ID - E-mail [email protected], of PAC of the first turnkey project (in case of
[email protected] Aburajab, contract award) or date of first delivery (in case
Contact Person Email ID - of direct material supply order), as confirmed,
[email protected] through their Letter #SEP-Telecom-WAR-20-0002
dated December 20, 2020, shall be applicable for
the equipment to be supplied to SEC/National Grid
SA.

20. 13 Page 555 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL SYSTEMS ALFDASA-57.01, The Telecom GCC Electrical PQ Letter


Saudi Arabia Cabinet/Rack shall be as per equipment Power Lab, Based on S&SD letter # MPQ1110618720 dated
OEM approved design. Dammam, report No. February 28, 2024, the manufacturer is
Plant -3Rd Industrial Area, Al Kharaj C008 -01-23R0 prequalified for Telecom Cabinets and Racks as
Road, Riyadh Saudi Arabia Dated: 16th confirming to National Grid SA specification #
November 2023. 48-TMSS-13, with the following conditions:
Po Box 301 , Riyadh 11411 , North Righ
Road Between Exit 5 & 6 Riyadh ,
Saudi Arabia WARRANTY
Ten (10) years extended warranty/guarantee to
Riyadh SEC/National Grid SA for the Telecom Cabinets
and Racks in respect of the defects due to
Contact Person - Sultan Alghamdi " VIP design, manufacturing, installation and
key Account Manegr "; Saleh workmanship from the date of Provisional
Almehaijeen "Projects Sales Engineer " Acceptance Certificate (PAC) of the first turnkey
Phone - 920006111 project (in case of contract award) or from the
Contact Person Email ID - date of first delivery (in case of direct material
[email protected]; supply order), as confirmed by the manufacturer,
[email protected] through their Letter Ref. # Nil dated 19.02.2024
Website - www.alfanar.com

Total = 2

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 14
Ethernet Switch Applicable Standards: 48-TMSS-10

20. 14 Page 556 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Huawei Technologies Co., Ltd. Huawei Tech. Investment S5720-52X-PWR-SI-AC; Huawei GCTC PQ Letter
CHINA Saudi Arabia Co,. LTD. (Global Compliance Based on S&SD letter # 19-00756-30504401
Huawei Technologies S5731, S5732 and S5735 Testing Center) dated June 20, 2019, the manufacturer is
Plant -Sonshan, Dongguan Investment Saudi Arabia Address NO.2 New prequalified for Ethernet Switch as confirming to
Ltd. Co. City Avenue Song National Grid SA specification # 48-TMSS-10,
Huawei - Song Shan Hu Technology Prince Mohammed Bin Shan Lake Sci. with the following conditions:
IndustrialPark NA dongguan China PRC Abdulaziz Street (Tahliah &Tech. Industry
St.) Olaya – Riyadh Park, Dongguan, WARRANTY
Contact Person - Liu Yong C-Center. P.O. Box Guangdong, P.R.C. Ten (10) years extended warranty from the date
Phone - 0507981437 295320, Riyadh 11351 Test Date 2017.4.19 of PAC of the first turnkey project (in case of
Email ID - [email protected] +966 507981437 - 2017.4.24 contract award) or from date of first delivery (in
Website - huawei.com [email protected] case of direct material supply order), as
confirmed, vide Huawei Letter No. Nill dated
14/10/2016 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.

WARRANTY
Ten (10) years extended warranty/guarantee for
the offered Ethernet Switch with series S5731,
S5732 and S5735 in respect of defects due to
design, manufacture, installation & workmanship
from the date of Provisional Acceptance
Certificate (PAC) of the first turnkey project in
case of contract award or date of delivery in
case of direct material supply order, as
confirmed vide Huawei Technologies Co., Ltd.
letter No. NIL Dated 27 October 2020

20. 14 Page 557 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MICROSENS GmbH & Co. KG 1. MS400890MX-BS Type Tests PQ Letter


GERMANY 2. MS652119PM-BS successfully
3. MS650919PM-BS completed at Based on S&SD letter 23-00538-30504401 dated
Plant -Germany 4. MS400890MX-BS (48 ports) PHOENIX – May 01, 2023, the manufacturer is prequalified
Germany, Test for Ethernet Switch type MS400890MX-BS as
D-59067 Hamm report No. confirming to National Grid SA specification
U190996E1 & #48-TMSS-10, with the following conditions:
Contact Person - Mr. Dirk Herppich, E190996E1, and
Technical Consultant SGS report No. WARRANTY
Phone - +492381/9452-0 P1Z80001.
Email ID - [email protected] Ten (10) years extended warranty from the date
Contact Person Email ID - of PAC of the first turnkey project (in case of
[email protected]; contract award) or date of first delivery (in case
[email protected] of direct material supply order), as confirmed,
Website - www.microsens.com through their Letter # Nill dated April 17, 2023,
shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

PQ Letter
Based on S&SD letter # #MPQ 11749219 dated
January 19, 2020, the manufacturer is
prequalified for Ethernet Switch as confirming to
National Grid SA specification # 48-TMSS-10,
with the following conditions:

WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter #Nil dated March 28, 2018,
shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

Total = 2

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 15
Communication Services Router Applicable Standards: 48-TMSS-11

20. 15 Page 558 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Huawei Technologies Co., Ltd. Huawei Tech. Investment NE08E-S6 Huawei GCTC PQ Letter
CHINA Saudi Arabia Co,. LTD. (Global Compliance Based on S&SD letter# 19-00755-30504401
Huawei Technologies NE series ( 8000, 9000 and 40E series) Testing Center) dated June 20, 2019, the manufacturer is
Plant -Sonshan, Dongguan Investment Saudi Arabia Address NO.2 New prequalified for Communication Services Router
Ltd. Co. City Avenue Song as confirming to National Grid SA specification #
Huawei - Song Shan Hu Technology Prince Mohammed Bin Shan Lake Sci. 48-TMSS-11, with the following conditions:
IndustrialPark NA dongguan China PRC Abdulaziz Street (Tahliah &Tech. Industry
St.) Olaya – Riyadh Park, Dongguan, WARRANTY
Contact Person - Liu Yong C-Center. P.O. Box Guangdong, P.R.C. Ten (10) years extended warranty from the date
Phone - 0507981437 295320, Riyadh 11351 Test Date 2017.4.19 of PAC of the first turnkey project (in case of
Email ID - [email protected] +966 507981437 - 2017.4.24 contract award) or from the date of first delivery
Website - huawei.com [email protected] (in case of direct material supply order), as
confirmed, vide Huawei Letter No. Nill dated
14/10/2016 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.

WARRANTY
Ten (10) years extended warranty/guarantee for
the offered Routers in respect of defects due to
design, manufacture, installation & workmanship
from the date of Provisional Acceptance
Certificate (PAC) of the first turnkey project in
case of contract award or date of delivery in
case of direct material supply order, as
confirmed vide Huawei Technologies Co., Ltd.
letter No. NIL Dated 27 October 2020 & letter No.
NIL Dated 18 January 2021

Total = 1

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 16
OPTICAL FIBER AMPLIFIER (OFA) DEVICES, SUBSYSTEMS OR COMPONENTS Applicable Standards: 48-TMSS-20

20. 16 Page 559 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Huawei Technologies Co., Ltd. Mr. Ryan Liu Optix OSN 8800 Intelligent Optical July 02,2019, PQ Letter
CHINA +966 507981437 Transmission System; Model: OSN Huawei Global
[email protected] 8800 Compliance & Based on S&SD letter# MPQ459820020-Class I(a)
Plant -Sonshan, Dongguan OptiX OSN 9800 series (OSN 9800 Testing Center, SGS -2018 dated August 04, 2019, & S&SD letter
M12, OSN 9800 M24, OSN 9800 M05 Test Report No. #21-00071/01-030504401 dated February 16,
Huawei - Song Shan Hu Technology and OSN 9800 Universal Platform IN-SUZ-5301-19012, 2021 the manufacturer is prequalified for
IndustrialPark NA dongguan China PRC Sub-rack) Shanghai, China. OPTICAL FIBER AMPLIFIER (OFA) DEVICES,
SUBSYSTEMS OR COMPONENTS as confirming
Contact Person - Liu Yong to National Grid SA specification # 48-TMSS-20
Phone - 0507981437 rev.00, with the following conditions:
Email ID - [email protected]
Website - huawei.com WARRANTY

Ten (10) years extended warranty from the date


of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter No. AJC/PQ-GW(2010/01)
dated August 01/2018 & Letter # AJC/PQ-GW
dated 31 December 2020. shall be applicable for
the equipment to be supplied to SEC/National Grid
SA.

20. 16 Page 560 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

IPG PHOTONICS Al Salam Industrial & OSTP-DWDM Type Tests were PQ Lettter
United States Trdg Est Erbium Amplifier rack Mount(EAR) and conducted in VDE Based on S&SD letter # 15-05564-2-30504401
Head Office,PO Raman Amplifier Rack Mount(RAR) Germany in dated July 05, 2015, it is pre-qualified for supply,
50 Old Webster Road Oxford Ma01540 Box:17176 presence of three installation and configuration of Optical Service
T 508 373 1100 F 508.373.1101 Jeddah-21484 Saudi SEC/National Grid Transport Platform (OSTP-DWDM), Erbium
Arabia SA Engineers during Amplifier rack Mount (EAR) and Raman Amplifier
Contact Person - Mr. Mark Cannata Tel: +966 12 608 1028 8th to 19th Rack Mount (RAR) manufactured by IPG
Director & Marketing &Mr. Yasser Fax: +966 12 608 1035 December Photonics, Oxford, Massachusetts, USA plant as
Adnan Skik [email protected] 2014.Three Failed conforming to National Grid SA specification #
Website - test (EMC Emission 48-TMSS-08 with following condition:
http://www.ipgphotonics.com of
Enclosure,Dielectric/I WARRANTY
nsulation Resistance Ten (10) years Extended Warranty as confirmed
and Mechanical through
Operation tests) IPG Letter # NIL dated 2nd April 2014 shall be
were repeated applicable for all supplies made to the Company
during 13th to 17th by IPG Photonics Oxford, Massachusetts, USA.
April 2015.Test Lab
RMS and Type Test
Report # MI-1220-4
dated 09-05-2011

20. 16 Page 561 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

IPG PHOTONICS Al Salam Industrial & OSTP-DWDM Type Tests were PQ Lettter
ITALY Trdg Est Erbium Amplifier rack Mount(EAR) and conducted in VDE Based on S&SD letter # 15-05564-3-30504401
Head Office,PO Raman Amplifier Rack Mount(RAR) Germany in dated July 05, 2015, it is pre-qualified for supply,
50 Old Webster Road Oxford Ma01540 Box:17176 presence of three installation and configuration of Optical Service
T 508 373 1100 F 508.373.1101 Jeddah-21484 Saudi SEC/National Grid Transport Platform (OSTP-DWDM), Erbium
Arabia SA Engineers during Amplifier rack Mount (EAR) and Raman Amplifier
Contact Person - Mr. Mark Cannata Tel: +966 12 608 1028 8th to 19th Rack Mount (RAR) manufactured by IPG
Director & Marketing &Mr. Yasser Fax: +966 12 608 1035 December Photonics, Milan Italy conforming to National Grid
Adnan Skik [email protected] 2014.Three Failed SA specification # 48-TMSS-08 with following
Website - test (EMC Emission condition:
http://www.ipgphotonics.com of
Enclosure,Dielectric/I WARRANTY
nsulation Resistance Ten (10) years Extended Warranty as confirmed
and Mechanical through
Operation tests) IPG Letter # NIL dated 2nd April 2014 shall be
were repeated applicable for allSupplies made to the Company
during 13th to 17th by IPG Photonics Milan Italy.
April 2015. Type
Test
Report#MI-1220-4
dated 09-05-2011

Total = 3

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 17
PACKET TRANSPORT SYSTEM BASED ON MPLS-TP Applicable Standards: 48-TMSS-21

20. 17 Page 562 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Huawei Technologies Co., Ltd. Huawei Tech. Investment PTN990 Huawei GCTC PQ Letter
CHINA Saudi Arabia Co,. LTD. PTN 910 (Global Compliance Based on S&SD letter# MPQ 354920620 dated
Huawei Technologies PTN 7900-12 & Testing Center) May 28, 2019, the manufacturer is prequalified
Plant -Sonshan, Dongguan Investment Saudi Arabia PTN 990E Test Date for PACKET TRANSPORT SYSTEM BASED ON
Ltd. Co. 03.04.2019 – MPLS-TP as confirming to National Grid SA
Huawei - Song Shan Hu Technology Prince Mohammed Bin 11.04.2019 specification # 48-TMSS-21, with the following
IndustrialPark NA dongguan China PRC Abdulaziz Street (Tahliah conditions:
St.) Olaya – Riyadh
Contact Person - Liu Yong C-Center. P.O. Box WARRANTY
Phone - 0507981437 295320, Riyadh 11351 Ten (10) years extended warranty from the date
Email ID - [email protected] +966 507981437 of PAC of the first turnkey project (in case of
Website - huawei.com [email protected] contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed, vide Huawei Letter No. Nil dated
01/08/2018 which shall be applicable for the
equipment to be supplied to SEC/National Grid SA

WARRANTY
Ten (10) years extended warranty/guarantee for
the offered MPLS-TP model PTN 990E in respect
of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed vide Huawei Technologies
Co., Ltd. letter No. NIL Dated 27 October 2020

20. 17 Page 563 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CORIANT GMBH Mr. Mohammad Ibrahim MPLS-TP models 7090-240 M-1 and Type Tests were PQ Letter
GERMANY [email protected] 7090-100 CEM successfully
m completed at Based on S&SD letter # MPQ456320620 dated
St. Martin Str. 76 81541 Munich PHOENIX, Germany - May 05, 2020, the manufacturer Infinera (Coriant)
Germany SGS Report is prequalified for PACKET TRANSPORT SYSTEM
#5142914#10, dated BASED ON MPLS-TP as confirming to National
Contact Person - Mr. Olaf Horsthemke 22 November 2019. Grid SA specification # 48-TMSS-21, with the
Managing Director following conditions:
Phone - +49-89-540215006
Email ID - • Manufacturer confirm that
[email protected] manufactured/assembled and dispatched
equipments will be supplied from Coriant
GMBH/ML&S located in 17489 Greifswald,
Germany, as confirmed, through Letter #nill dated
#25.02.2020

WARRANTY

Ten (10) years extended warranty from the date


of PAC of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed, through their Letter
#SEC170316LTR32 dated #17.03.2016, shall be
applicable for the equipment to be supplied to
SEC/National Grid SA.

20. 17 Page 564 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

OTN Systems NV NESIC S.A. Co. LTD XT2210-A and XT2215-A Type Tests PQ Letter
BELGIUM NESIC SA successfully Based on S&SD letter # MPQ 460220620 dated
Mezzanine Flr. completed at January 21, 2020, the manufacturer OTN
Plant -Belgium Saudi Consolidated & Denayer – Belgium , Systems NV, Belgium is prequalified for PACKET
Contracting Bldg. Test report No. TRANSPORT SYSTEM BASED ON MPLS-TP as
Industrielaan 17b 2250 Olen 16B Cross Hafith Ibrahim PCC-CLI-5021, and confirming to National Grid SA specification #
Industrielaan Olen St. Type Test Report 48-TMSS-21, with the following conditions:
Al Khobar 34447 issued on October
Contact Person - Francis Baestaens; 17, 2019. WARRANTY
Khaled Abu Sharar Ten (10) years extended warranty from the date
Phone - +32 473653992; 0553581743 of PAC of the first turnkey project (in case of
Email ID - contract award) or date of first delivery (in case
[email protected]; of direct material supply order), as confirmed,
[email protected] through their Letter #MPQ460220620-Class I(b)
Website - http://www.otnsystems.com -2018 dated #March 11, 2020, shall be applicable
for the equipment to be supplied to SEC/National
Grid SA.

Hitachi Energy Switzerland Ltd. Hitachi Energy Ltd. FOX 615 (Hybrid Multi-Service The type test details PQ Letter
SWITZERLAND 2 Industrial Area 61 Platform) with CESM1/2/3 modules (Date, Test Based on S&SD Letter # MPQ675620620 dated
Corner, 224 Streets Laboratory, November 20, 2022., the manufacturer is
Plant -switzerland Riyadh 11643, Riyadh, Location) shall be prequalified for Packet Transport System Based
Saudi Arabia taken from the file on MPLS-TP as conforming to National Grid SA
Bruggerstrasse 72, 5400 Baden +966 11265 3030 Ext. “Final KEMA Report specification # 48-TMSS-21 Rev.01, with the
1798 +966 530156584 (FOX615 MPLS-TP)” following conditions:
Baden mohammed.ilyas@hitachi on an e-mail to
energy.com SEC/NG P&SFD Warranty:
Contact Person - Mr. Ahmed Abubasha, dated July 19, 2022 Ten (10) years extended warranty from the date
Mr. Abdulmajeed Alothman, Mr. Michal which was received of PAC of the first turnkey project (in case of
Adamski , Mr. Mohammed Ilyas from Hitachi Energy contract award) or date of first delivery (in case
Phone - +41 58 588 33 50,+41 58 585 (Middle East) with of direct material supply order). as confirmed,
77 44 the subject, ‘PQ - through their letter No. Nill, dated May 20, 2021,
Email ID - MPQ675620620-Cla shall be applicable for the equipment to be
communication.networks@hitachienerg ss III-2019 FOX615 supplied to SEC/National Grid SA.
y.com MPLS-TP Plant visit,
Contact Person Email ID - Type Test and
[email protected] Functionality
om Testing’.
,[email protected]
Website - www.hitachienergy.com

Total = 4

20. 17 Page 565 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

COMMUNICATIONS & FIBER OPTIC EQUIPMENT


20. 25
Remote Fiber Testing System Applicable Standards: 48-TMSS-14

EXFO Telecom Equipment (Shenzhen) Mr. Mirza Arsalan Baig Fiber Guardian FG-750 Type test performed PQ Letter
Ltd 6/F Raqtan Building, 159 in Intertek testing Based on S&SD letter # 23-02505-030504401
CHINA Dabbab St. P.O. Box services NA 731 dated November 23, 2023, the manufacturer is
7650, Riyadh 11472 Enterprise Drive prequalified for Remote Fiber Testing System
Plant -Shenzhen, China Saudi Arabia Lexington, KY (RFTS) as confirming to National Grid SA
M:0506228193, 40510, USA. specification # 48-TMSS-14 Rev.00 with
EXFO - F1 to F3 No. 71-3 Xintian 011-2161391 Ext 1400 following conditions:
Shenzhen Guangdong China PRC 011 2161939
[email protected] WARRANTY:
Shenzhen m Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for Remote Fiber Testing
Contact Person - Mr. Allen Rebello Mr. System (RFTS) in respect of the defects due to
David Watts design, manufacturing, installation and
Contact Person Email ID - workmanship from the date of Provisional
[email protected] Acceptance Certificate (PAC) of the first turnkey
[email protected] project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # NGSA _
FG_WRTY-10Y dated April 2nd , 2021.

Total = 1

TRANSFORMERS, CURRENT AND POTENTIAL


21. 1
CURRENT TRANSFORMER,(33 & 34.5 KV CTS) Applicable Standards: 50-TMSS-01

SIEMENS
United States

Website -
http://www.usa.siemens.com/entry/en/

21. 1 Page 566 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB EJF
CZECH REPUBLIC

Website -
http://www.abb.com/substation-autom
ation

ELEQ B.V. Hamid Nazar Malik Up to 380 kV Type Test were PQ Lettter
GERMANY Contracting Co. Ltd ( Split core and continuous Ring type witnessed Based on S&SD letter# 15-10406-01-30504401,
HNCC) CTs successfully by dated
Zweigniederlassung Deutschland , Contact Person:Mr. umer SEC/ National Grid December 10, 2015. the manufacturer is
Karl-Ferdinand-Braun-Strabe 150170 Shaikh, P.O.Box 132631 SA engineers during prequalified for Split Core and Continuous Ring
Kerpen Germany Jeddah 21382,Kingdom 20th to 24th October type CTs up to 380kV as conforming to National
of Saudi 2015 in IPH Germany Grid SA 50-TMSS-01 Rev.0 with the following
Contact Person - Dr. Andreas Roos, Arabia,http://hnccsa.com Type Test Report, condition
General Manager / SGS Germany
Phone - +49-0-2273-988-70 Tel : 00966 2 ref#3534308-10 WARRANTY:
Email ID - [email protected] 6752400,Tel : 00966 2 Ten (10) years Extended Warranty shall be
Website - http://www.eleq.com 6758838, Mobil applicable for Split Core and Continuous Ring
Email : type CTs up to 380kV to be supplied to
[email protected],sales SEC/National Grid SA as confirmed through Letter
@hnccsa.com # Nil dated 05.08.2015.

- Previously KWK Messwandler

21. 1 Page 567 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELECTROTECNICA ARTECHE HNOS. Type / Model: Current Transformer PQ Letter:


S.L./ E.A.H.S.L S&SD Letter 12-03192-02-30504001 dated
SPAIN Rating: 33kV & 34.5kV February 19, 2012, it is pre-qualified for 33 kV &
34.5 kV Current Transformers (CTs).
Plant -Mungia, Spain CA-36 / 33 & 34.5kV
CONDITION:
Electrotecnica Arteche Hnos. S.L./ All Type, Routine and Special testes shall be
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea carried out on the first batch of 33 kV & 34.5 kV
Nº28 48100/ Current Transformers (CTs) kV in an Independent
Testing Laboratory in the presence of three (3)
Contact Person - Mr. Roberto Antuñano SEC Engineers & one (1) SEC approved
Phone - +946011200 Independent Inspection Agency (IIA) Inspector.
Email ID - [email protected] All costs of which shall be borne by the
Website - http://www.arteche.es manufacturer. This was confirmed by the
manufacturer through their letter # Nil dated April
28, 2011G.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.

21. 1 Page 568 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MEMF Type / Model: CT (Blocktype) PQ Letter:


Saudi Arabia TS&SD letter# 09-00918-03032301 dated 29
Rating: up to 36kV March 2009 prequalified for CT up to 36kV.
Riyadh , Saudi Arabia
CONDITION:
Website - http://memf.com.sa/ TYPE TEST SHALL BE DONE AT AN INTL.
TESTING LAB IN PRESENCE OF 3RD PARTY
INSPECTOR

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.MEMF/YS/LET/08/180, dt: 21st Sep,
2008...

KONCAR INSTRUMENT Nesma Telecom & CONDITION:


TRANSFORMERS INC. Technology Co. Ltd. All Type, Special, Routine tests per SEC
CROATIA Nesma Telecom & Standards and IEC to be performed at
Technology Co. Ltd. KONCAR-Electrical Institute Inc. as independent
Plant -Zagreb, Hrvatska, Croatia (NESMA ELECTRIC), and accredited testing laboratory.
Jeddah, Asfan Road
Josipa Mokrovica 10; HR-10090 inside azzam compound WARRANTY:
Zagreb, Croatia +966 12 422 9750 Ext. Ten (10) years extended warranty/guarantee in
3522 +966506513637 respect of defects due to design, manufacture,
Contact Person - Mr. Marcel Folnović , [email protected] installation & workmanship from the date of
Area Manager- Sales & Marketing [email protected] Provisional Acceptance Certificate (PAC) of the
Department om first turnkey project in case of contract award or
Phone - +385 1 379 5240, +385 1 379 date of delivery in case of direct material supply
4112 Mob: +385 99 249 3039 order.
Email ID -
[email protected]
Website - http://www.koncar-mjt.hr

SADTEM Type / Model: RING/SPLIT CORE TYPE &


FRANCE BLOCK TYPE CTs

Website - http://www.sadtem.com/ Rating: UP TO 36kV

21. 1 Page 569 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

STE Type / Model: RING/SPLIT CORE TYPE


ITALY

KUHLMAN ELECTRIC CORPORATION Type / Model: RING/SPLIT CORE TYPE


United States

Website - http://www.kuhlman.com/

GE
United States

Plant -United States

Website - http://www.ge.com/

PFIFFNER Type / Model: RING/SPLIT CORE TYPE


SWITZERLAND

Website - http://www.pfiffner.com/

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 12

TRANSFORMERS, CURRENT AND POTENTIAL


21. 2
CURRENT TRANSFORMER, (69KV CTS) Applicable Standards: 50-TMSS-01

SIEMENS
United States

Website -
http://www.usa.siemens.com/entry/en/

21. 2 Page 570 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

TRENCH ITALIA Type / Model: PREVIOUSLY AS VA TECH (NOUVA MAGRINI


ITALY OIL TYPE GALILEO);

Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html

E. PFIFFNER
SWITZERLAND

Website -
http://www.pmw.ch/default.htm

ELECTROTECNICA ARTECHE HNOS. Type / Model: Current Transformer, PQ Letter:


S.L./ E.A.H.S.L CXH-72 S&SD Letter 12-03192-02-30504001 dated
SPAIN Rating: 69kV February 19, 2012, it is pre-qualified for 69 kV
Current Transformers (CTs).
Plant -Mungia, Spain CA-72
Rating: 69kV WARRANTY:
Electrotecnica Arteche Hnos. S.L./ Ten (10) years extended warranty/guarantee in
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea respect of defects due to design, manufacture,
Nº28 48100/ installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. Roberto Antuñano first turnkey project in case of contract award or
Phone - +946011200 date of delivery in case of direct material supply
Email ID - [email protected] order, as confirmed by the manufacturer thru
Website - http://www.arteche.es letter #nil, dt: Jan 11, 2010.

21. 2 Page 571 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
TYPE TEST SHALL BE DONE AT AN INTL.
TESTING LAB IN PRESENCE OF 3RD PARTY
INSPECTOR

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Trench. S.A.S Siemens SA, Riyad Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 2 Page 572 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR INSTRUMENT Nesma Telecom & CONDITION:


TRANSFORMERS INC. Technology Co. Ltd. All Type, Special, Routine tests per SEC
CROATIA Nesma Telecom & Standards and IEC to be performed at
Technology Co. Ltd. KONCAR-Electrical Institute Inc. as independent
Plant -Zagreb, Hrvatska, Croatia (NESMA ELECTRIC), and accredited testing laboratory.
Jeddah, Asfan Road
Josipa Mokrovica 10; HR-10090 inside azzam compound WARRANTY:
Zagreb, Croatia +966 12 422 9750 Ext. Ten (10) years extended warranty/guarantee in
3522 +966506513637 respect of defects due to design, manufacture,
Contact Person - Mr. Marcel Folnović , [email protected] installation & workmanship from the date of
Area Manager- Sales & Marketing [email protected] Provisional Acceptance Certificate (PAC) of the
Department om first turnkey project in case of contract award or
Phone - +385 1 379 5240, +385 1 379 date of delivery in case of direct material supply
4112 Mob: +385 99 249 3039 order.
Email ID -
[email protected]
Website - http://www.koncar-mjt.hr

SADTEM Type / Model: RING/SPLIT CORE TYPE


FRANCE

Website - http://www.sadtem.com/

STE Type / Model: RING/SPLIT CORE TYPE


ITALY

ELEQ B.V. Split core and continuous Ring type PQ Letter


GERMANY CTs up to 380kV. Based on S&SD letter# 15-10406-01-30504401,
dated December 10, 2015. the manufacturer is
Germany-Kerpen prequalified for Split Core and Continuous Ring
type CTs up to 380kV with the following
condition.

WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core and Continuous Ring
type CTs up to 380kV to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 05.08.2015.

- Previously KWK Messwandler

21. 2 Page 573 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KUHLMAN ELECTRIC CORPORATION Type / Model: RING/SPLIT CORE TYPE


United States
Rating:
Website - http://www.kuhlman.com/

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

GE
United States

Plant -United States

Website - http://www.ge.com/

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

PFIFFNER Type / Model: RING/SPLIT CORE TYPE


SWITZERLAND

Website - http://www.pfiffner.com/

ABB-Ludvika
SWEDEN

Plant -Sweden

Ludvika, Sweden

Contact Person - Mr. Magnus


Johansson
Phone - +46 240 783228
Email ID -
[email protected]
Website - http://www.abb.se/

21. 2 Page 574 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 19

TRANSFORMERS, CURRENT AND POTENTIAL


21. 3
CURRENT TRANSFORMER, 11 KV THROUGH 380 KV (110 - 132 KV CTS) Applicable Standards: 50-TMSS-01

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 3 Page 575 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TRENCH ITALIA Type / Model: OIL TYPE PREVIOUSLY AS VA TECH (NOUVA MAGRINI
ITALY GALILEO);

Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html

ELECTROTECNICA ARTECHE HNOS. Type / Model: Current transformer Tests done in LCOE PQ Letter:
S.L./ E.A.H.S.L Laboratoty (Spain) Based on S&SD letter # 16-010639-030504401
SPAIN •Type CA-170 in presence of dated February 16,2017, Electrotecnica Arteche,
Rating: 110 kV SEC/National Grid Spain-Mungia is pre-qualified for 110 kV CTS as
Plant -Mungia, Spain SA Engineers from conforming to National Grid SA specification #
11th to 19th July, 50-TMSS-01, with the following condition:
Electrotecnica Arteche Hnos. S.L./ 2016).
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea •Ten (10) years extended warranty from the date
Nº28 48100/ of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
Contact Person - Mr. Roberto Antuñano of direct material supply order), as confirmed
Phone - +946011200 through Electrotecnica Arteche letter # NIL dated
Email ID - [email protected] January 11, 2010 G.
Website - http://www.arteche.es

21. 3 Page 576 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All Type, Special, Routine tests per SEC
Standards shal be performed on the first batch,
at anaccredited testing laboratory in the
presence of 03 SEC/National Grid SA engineers
and one approved third party inspector and the
cost of which shall be borne by the
manufacturer.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Trench. S.A.S Siemens SA, Riyad Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 3 Page 577 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR INSTRUMENT Nesma Telecom & Type / Model: Report No. PQ Letter:
TRANSFORMERS INC. Technology Co. Ltd. 215841P9006&2158 Based on S&SD letter # 20-00850-30504401
CROATIA (NESMA ELECTRIC) Rating: 110 - 132KV 41K19007 dated dated July 5, 2020, the manufacturer is
Nesma Telecom & 16-01-2019 prequalified for 132kV current Transformer type
Plant -Zagreb, Hrvatska, Croatia Technology Co. Ltd. AGU-145 Report No. 018035 AGU-145 with following condition:
(NESMA ELECTRIC), dated 15-11-2018
Josipa Mokrovica 10; HR-10090 Jeddah, Asfan Road WARRANTY:
Zagreb, Croatia inside azzam compound Ten (10) years extended warranty/guarantee in
+966 12 422 9750 Ext. respect of defects due to design, manufacture,
Contact Person - Mr. Marcel Folnović , 3522 +966506513637 installation & workmanship from the date of
Area Manager- Sales & Marketing [email protected] Provisional Acceptance Certificate (PAC) of the
Department [email protected] first turnkey project in case of contract award or
Phone - +385 1 379 5240, +385 1 379 om date of delivery in case of direct material supply
4112 Mob: +385 99 249 3039 order.
Email ID -
[email protected]
Website - http://www.koncar-mjt.hr

PFIFFNER Type / Model: RING/SPLIT CORE


SWITZERLAND

Website - http://www.pfiffner.com/

SADTEM Type / Model: RING/SPLIT CORE RING/SPLIT CORE TYPE


FRANCE

Website - http://www.sadtem.com/

STE Type / Model: RING/SPLIT CORE RING/SPLIT CORE TYPE


ITALY

21. 3 Page 578 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELEQ B.V. Split core and continuous Ring type PQ Letter


GERMANY CTs up to 380kV Based on S&SD letter# 15-10406-01-30504401,
dated December 10, 2015. the manufacturer is
Germany-Kerpen prequalified for Split Core and Continuous Ring
type CTs up to 380kV with the following
condition:

WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core and Continuous Ring
type CTs up to 380kV to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 05.08.2015.

- Previously KWK Messwandler

KUHLMAN ELECTRIC CORPORATION Type / Model: RING/SPLIT CORE TYPE


United States

Website - http://www.kuhlman.com/

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 16

21. 3 Page 579 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TRANSFORMERS, CURRENT AND POTENTIAL


21. 4
CURRENT TRANSFORMER,( 230KV CTS) Applicable Standards: 50-TMSS-01

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

TRENCH ITALIA Type / Model: OIL TYPE PREVIOUSLY AS VA TECH (NOUVA MAGRINI
ITALY GALILEO);

Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html

21. 4 Page 580 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Trench. S.A.S Siemens SA, Riyad Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 4 Page 581 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFIFFNER Type / Model: RING/SPLIT CORE TYPE


SWITZERLAND

Website - http://www.pfiffner.com/

SADTEM Type / Model: RING/SPLIT CORE TYPE


FRANCE

Website - http://www.sadtem.com/

STE Type / Model: RING/SPLIT CORE TYPE


ITALY

ELEQ B.V. Split core / Ring type CTs up to 380kV PQ Letter


GERMANY Based on S&SD letter# 15-10406-01-30504401,
dated December 10, 2015. the manufacturer is
Germany-Kerpen prequalified for Split Core /Ring type CTs up to
380kV with the following condition:

WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core / Ring type CTs up to
380kV to be supplied to SEC/National Grid SA as
confirmed through Letter# Nil dated 05.08.2015.

- Previously KWK Messwandler

KUHLMAN ELECTRIC CORPORATION Type / Model: RING/SPLIT CORE TYPE


United States

Website - http://www.kuhlman.com/

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

21. 4 Page 582 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELECTROTECNICA ARTECHE HNOS. CA-245 rated for 230kV PQ Letter


S.L./ E.A.H.S.L Based on S&SD letter # 18-02331-030504401
SPAIN dated July 8, 2018 Electrotecnica ARTECHE
Hermanos, S.L. - Mungia, Spain is pre-qualified
Plant -Mungia, Spain for 230kV Current Transformers (CTs), type
CA-245 as conforming to National Grid SA
Electrotecnica Arteche Hnos. S.L./ specification # 50-TMSS-01 , with the following
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea Type Test conditions:
Nº28 48100/
Warranty:
Contact Person - Mr. Roberto Antuñano Ten (10) years extended warranty/guaranty from
Phone - +946011200 the date of PAC of the first turnkey project (in
Email ID - [email protected] case of contract award) and from the date of
Website - http://www.arteche.es delivery (in case of direct material supply order),
as confirmed, through their letter # Nil, dated July
2, 2018 shall be applicable for all 230kV Current
Transformers (CTs), type CA-245 to be supplied
to SEC/National Grid SA.

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 15

TRANSFORMERS, CURRENT AND POTENTIAL


21. 5
CURRENT TRANSFORMER, (380KV CTS) Applicable Standards: 50-TMSS-01

21. 5 Page 583 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 5 Page 584 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Electrotecnica ARTECHE Hermanos, Innovative Systems Co. CA-420 type test was PQ letter:
S.L. Ltd. performed in LCOE Based on S&SD letter # MPQ # 102210921 dated
SPAIN P.O. Box 60606, Riyadh, lab - Spain 10th to November 08, 2017, Electrotecnica ARTECHE -
KSA 16th July 2017 Spain is pre-qualified for CURRENT
Plant -Mungia, Spain [email protected] TRANSFORMER,( 380KV CTS)as conforming to
latest National Grid SA specification #
Electrotecnica ARTECHE Hermanos, 50-TMSS-01
S.L.
DERIO BIDEA, 28 (Bº Zabalondo) WARRANTY:
48.100 - MUNGIA Spain Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Mungia installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - LANDER ZUGAZAGA first turnkey project in case of contract award or
& Kamal Al Muhanna date of first delivery in case of direct material
Phone - +34 94 601 1200 supply order, as confirmed by the manufacturer
Email ID - [email protected] vide letter # Nil, dated June 30, 2016.
Contact Person Email ID -
[email protected] & [email protected]
Website - www.arteche.es

TRENCH ITALIA PREVIOUSLY AS VA TECH (NOUVA MAGRINI


ITALY GALILEO);

Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html

21. 5 Page 585 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Trench. S.A.S Siemens SA, Riyad Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 5 Page 586 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR INSTRUMENT Nesma Telecom & AGU - 420 Type tests PQ Letter
TRANSFORMERS INC. Technology Co. Ltd. successfully Based on S&SD letter #MPQ456010921 dated
CROATIA (NESMA ELECTRIC), completed in March 16, 2020, the manufacturer is prequalified
Jeddah, Asfan Road Independent lab for 380KV Current Transformer as conforming to
Plant -Zagreb, Hrvatska, Croatia inside azzam compound KONCAR Electrical National Grid SA specification # 50-TMSS-01,
+966 12 422 9750 Ext. Engineering Institute with the following conditions:
Josipa Mokrovica 10; HR-10090 3522; +966506513637 - Croatia during 25 -
Zagreb, Croatia [email protected]; 31 October 2019,
[email protected] SGS report # WARRANTY
Contact Person - Mr. Marcel Folnović , om 500919, and Ten (10) years extended warranty from the date
Area Manager- Sales & Marketing laboratory report # of PAC of the first turnkey project (in case of
Department 056119. contract award) or date of first delivery (in case
Phone - +385 1 379 5240, +385 1 379 of direct material supply order), as confirmed,
4112 Mob: +385 99 249 3039 3150A Temperature through their Letter # Nil dated May 04, 2018 shall
Email ID - Rise Type test be applicable for the equipment to be supplied to
[email protected] successfully SEC/National Grid SA.
Website - http://www.koncar-mjt.hr completed in
Independent lab
KONCAR Electrical
Engineering Institute
- Croatia during 08 -
10 June 2021, SGS
report # 501038-01,
and laboratory
report # 018921.

21. 5 Page 587 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFIFFNER Type / Model: CT & CVT PQ Letter:


SWITZERLAND TS&SD letter# 09-01105-1-03032301 dated 24th
Rating: uo to 380kV June 2009, pre-qualified for CT & CVT rated up to
Website - http://www.pfiffner.com/ 380kV.

CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector, as
confirmed by the manufacturer through their
letter no.CH-5042 Hirchthal, dt: 17th May, 2009..

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.CH-5042 Hirchthal, dt: 17th May,
2009...

SADTEM Type / Model: RING/SPLIT CORE TYPE


FRANCE

Website - http://www.sadtem.com/

STE Type / Model: RING/SPLIT CORE TYPE


ITALY

21. 5 Page 588 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELEQ B.V. Split core / Ring type CTs up to 380kV PQ Lettter


GERMANY Based on S&SD letter# 15-10406-01-30504401,
dated December 10, 2015. the manufacturer is
Germany-Kerpen prequalified for Split Core / Ring type CTs up to
380kV with the following condition:

WARRANTY:
Ten (10) years Extended Warranty shall be
applicable for Split Core / Ring type CTs up to
380kV to be supplied to SEC/National Grid SA as
confirmed through Letter # Nil dated 05.08.2015.
- Previously KWK Messwandler

KUHLMAN ELECTRIC CORPORATION Type / Model: RING/SPLIT CORE TYPE


United States

Website - http://www.kuhlman.com/

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 16

TRANSFORMERS, CURRENT AND POTENTIAL


21. 6
POTENTIAL TRANSFORMER, (33 & 34.5 KV) Applicable Standards: 50-TMSS-03

21. 6 Page 589 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS
GERMANY

Website - http://
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

ABB EJF
CZECH REPUBLIC

Website -
http://www.abb.com/substation-autom
ation

21. 6 Page 590 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MEMF Type / Model: Resine cast MV voltage PQ Letter:


Saudi Arabia indoor PT S&SD Letter 12-00694-1-030504401 dated March
03, 2012. prequalified for Medium Voltage Resin
Riyadh , Saudi Arabia Rating: upt o 36kV Cast Indoor, Potential Transformers.

Website - http://memf.com.sa/ CONDITION:


This approval is restricted to Resin Cast, Indoor
Potential Transformers with accuracy class
including 0.5/3P (0.5%) rated up to 36kV. Any
other accuracy class including 0.2/3 P (0.2%) will
be considered only after submitting Type Test
Reports (acceptable to the Company) from
Independent Laboratory as confirmed by MEMF
through Letter # NIL dated February 13, 2012.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: oct 24, 2011.

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

21. 6 Page 591 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Trench. S.A.S Siemens SA, Riyad Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

KONCAR INSTRUMENT Nesma Telecom & PQ Letter:


TRANSFORMERS INC. Technology Co. Ltd.
CROATIA Nesma Telecom & CONDITION:
Technology Co. Ltd. All Type, Special, Routine tests per SEC
Plant -Zagreb, Hrvatska, Croatia (NESMA ELECTRIC), Standards and IEC to be performed at
Jeddah, Asfan Road KONCAR-Electrical Institute Inc. as independent
Josipa Mokrovica 10; HR-10090 inside azzam compound and accredited testing laboratory.
Zagreb, Croatia +966 12 422 9750 Ext.
3522 +966506513637 WARRANTY:
Contact Person - Mr. Marcel Folnović , [email protected] Ten (10) years extended warranty/guarantee in
Area Manager- Sales & Marketing [email protected] respect of defects due to design, manufacture,
Department om installation & workmanship from the date of
Phone - +385 1 379 5240, +385 1 379 Provisional Acceptance Certificate (PAC) of the
4112 Mob: +385 99 249 3039 first turnkey project in case of contract award or
Email ID - date of delivery in case of direct material supply
[email protected] order.
Website - http://www.koncar-mjt.hr

SADTEM Type / Model: BLOCK TYPE PTs


FRANCE
Rating: UP TO 36kV.
Website - http://www.sadtem.com/

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

21. 6 Page 592 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFIFFNER, HIRSCHTHAL
SWITZERLAND

Plant -Hirschthal, Switzerland

Website - http://www.pfiffner.com/

GE
United States

Plant -United States

Website - http://www.ge.com/

ELECTROTECNICA ARTECHE HNOS. Type / Model: Potential Transformer PQ Letter:


S.L./ E.A.H.S.L S&SD Letter 12-03192-02-30504001 dated
SPAIN Rating: 33 kV & 34.5 kV February 19, 2012, pre-qualified for 33 kV & 34.5
kV Potential Transformers (PT).
Plant -Mungia, Spain UTD-52 / 33 & 34.5 kV
& CONDITION:
Electrotecnica Arteche Hnos. S.L./ UTB-52 / 33 & 34.5 kV All Type, Routine and Special testes shall be
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea carried out the complete tests in one (1) sample
Nº28 48100/ of the first batch of 33 kV & 34.5 kV Potential
transformer (PT) in an Independent Testing
Contact Person - Mr. Roberto Antuñano Laboratory in the presence of three (3) SEC
Phone - +946011200 Engineers & one (1) SEC approved Independent
Email ID - [email protected] Inspection Agency (IIA) Inspector. All costs of
Website - http://www.arteche.es which shall be borne by the manufacturer. This
was confirmed by the manufacturer through their
letter # Nil, dated April 28, 2011G.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.

21. 6 Page 593 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 14

TRANSFORMERS, CURRENT AND POTENTIAL


21. 7
POTENTIAL TRANSFORMER, (69 KV ) Applicable Standards: 50-TMSS-03

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 7 Page 594 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Trench. S.A.S Siemens SA, Riyad Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 7 Page 595 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR INSTRUMENT Nesma Telecom & CONDITION:


TRANSFORMERS INC. Technology Co. Ltd. All Type, Special, Routine tests per SEC
CROATIA Nesma Telecom & Standards and IEC to be performed at
Technology Co. Ltd. KONCAR-Electrical Institute Inc. as independent
Plant -Zagreb, Hrvatska, Croatia (NESMA ELECTRIC), and accredited testing laboratory.
Jeddah, Asfan Road
Josipa Mokrovica 10; HR-10090 inside azzam compound WARRANTY:
Zagreb, Croatia +966 12 422 9750 Ext. Ten (10) years extended warranty/guarantee in
3522 +966506513637 respect of defects due to design, manufacture,
Contact Person - Mr. Marcel Folnović , [email protected] installation & workmanship from the date of
Area Manager- Sales & Marketing [email protected] Provisional Acceptance Certificate (PAC) of the
Department om first turnkey project in case of contract award or
Phone - +385 1 379 5240, +385 1 379 date of delivery in case of direct material supply
4112 Mob: +385 99 249 3039 order.
Email ID -
[email protected]
Website - http://www.koncar-mjt.hr

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

PFIFFNER, HIRSCHTHAL
SWITZERLAND

Plant -Hirschthal, Switzerland

Website - http://www.pfiffner.com/

21. 7 Page 596 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELECTROTECNICA ARTECHE HNOS. Type / Model: Potential Transformer PQ Letter:


S.L./ E.A.H.S.L S&SD Letter 12-03192-02-30504001 dated
SPAIN Rating: 69 kV February 19, 2012, pre-qualified for 69 kV
Potential Transformers (PT).
Plant -Mungia, Spain UTD-72
& CONDITION:
Electrotecnica Arteche Hnos. S.L./ UTE-72 All Type, Routine and Special testes shall be
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea carried out the complete tests in one (1) sample
Nº28 48100/ of the first batch of 69 kV Potential Transformers
(PT) in an Independent Testing Laboratory in the
Contact Person - Mr. Roberto Antuñano presence of three (3) SEC Engineers & one (1)
Phone - +946011200 SEC approved Independent Inspection Agency
Email ID - [email protected] (IIA) Inspector. All costs of which shall be borne
Website - http://www.arteche.es by the manufacturer. This was confirmed by the
manufacturer through their letter # Nil dated April
28, 2011G.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 11

21. 7 Page 597 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TRANSFORMERS, CURRENT AND POTENTIAL


21. 8
POTENTIAL TRANSFORMER, (110 - 132 KV) Applicable Standards: 50-TMSS-03

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 8 Page 598 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order..

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Trench. S.A.S Siemens SA, Riyad Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 8 Page 599 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR INSTRUMENT Nesma Telecom & Type / Model: Type Test Reports: PQ letter:Based on S&SD letter
TRANSFORMERS INC. Technology Co. Ltd. 019010 dated #19-03729-30504401 dated January 5, 2020,
CROATIA Nesma Telecom & Rating: 110 - 132KV 07/02/2019 KONCAR-Instrument Transformer Inc. Croatia for
Technology Co. Ltd. 21584IK19007 dated 132kV Potential Transformer Type: VPU-145 as
Plant -Zagreb, Hrvatska, Croatia (NESMA ELECTRIC), VPU-145 14/01/2019 conforming to latest National Grid SA
Jeddah, Asfan Road 21584IP19006 dated specification # 50-TMSS-03, with the following
Josipa Mokrovica 10; HR-10090 inside azzam compound 14/1/2019 condition:
Zagreb, Croatia
Mr. Rayan Alamoudi , WARRANTY:
Contact Person - Mr. Marcel Folnović , Business Development Ten (10) years extended warranty/guarantee in
Area Manager- Sales & Marketing Manager respect of defects due to design, manufacture,
Department +966506513637 installation & workmanship from the date of
Phone - +385 1 379 5240, +385 1 379 [email protected] Provisional Acceptance Certificate (PAC) of the
4112 Mob: +385 99 249 3039 first turnkey project in case of contract award or
Email ID - date of delivery in case of direct material supply
[email protected] order.
Website - http://www.koncar-mjt.hr

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

ELECTROTECNICA ARTECHE HNOS. Type / Model: Potential Transformer Type Test Report # PQ Letter:
S.L./ E.A.H.S.L Rating: 110-132 kV 2017 03 3D 0108 S&SD Letter 12-03192-02-30504001 dated
SPAIN February 19, 2012, it is pre-qualified for 110 –
132 kV Potential Transformers (PT).
Plant -Mungia, Spain
WARRANTY:
Electrotecnica Arteche Hnos. S.L./ Ten (10) years extended warranty/guarantee in
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea respect of defects due to design, manufacture,
Nº28 48100/ installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. Roberto Antuñano first turnkey project in case of contract award or
Phone - +946011200 date of delivery in case of direct material supply
Email ID - [email protected] order, as confirmed by the manufacturer thru
Website - http://www.arteche.es letter #nil, dt: jan 11, 2010.

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

21. 8 Page 600 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFIFFNER INSTRUMENT Type / Model: Inductive Voltage PQ Letter:


TRANSFORMERS LTD Transformer TS&SD letter # 11-01326-02-03032301 dated
SWITZERLAND 04/12/2011, pre-qualified for Inductive Voltage
Rating: 110kV- 132kV 230kV Transformers from 110kV up to 230kV.
Hirschthal , Switzerland
CONDITION:
All type, special, routine and sample tests as per
SEC specifications /standards shall be carried
out on the first unit of Inductive Voltage
Transformers to be supplied to SEC in case of
securing an order in the presence of three (3)
SEC Engineers & one (1) approved independent
inspection agency Inspector in an independent
testing laboratory or at the manufacturer’s testing
laboratory. All the related costs for witnessing
the tests will be borne by the manufacturer. This
was confirmed by PFIFFNER Instrument
Transformers Ltd through letter #
P/900-17052011 dated 17 May 2011.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #P/900-25112010, dt: 22 mar, 2011.

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 11

TRANSFORMERS, CURRENT AND POTENTIAL


21. 9
POTENTIAL TRANSFORMER, (230 KV ) Applicable Standards: 50-TMSS-03

21. 9 Page 601 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 9 Page 602 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Trench. S.A.S Siemens SA, Riyadh Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 9 Page 603 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

ELECTROTECNICA ARTECHE HNOS. UTF-245 rated for 230kV PQ Letter


S.L./ E.A.H.S.L Based on S&SD letter # 18-02331-030504401
SPAIN dated July 8, 2018 Electrotecnica ARTECHE
Hermanos, S.L. - Mungia, Spain is pre-qualified
Plant -Mungia, Spain for 230kV Potential Transformers (VTs), type
UTF-245 as conforming to National Grid SA
Electrotecnica Arteche Hnos. S.L./ specification # 50-TMSS-03 , with the following
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea Type Test conditions:
Nº28 48100/ "The first batch of 230kV Potential Transformers
(VTs), type UTF-245 per 50-TMSS-03, to be
Contact Person - Mr. Roberto Antuñano supplied to SEC/National Grid SA shall be type
Phone - +946011200 tested in an accredited test laboratory in
Email ID - [email protected] presence of three (3) SEC/National Grid SA and
Website - http://www.arteche.es one (1) SEC/National Grid SA approved IIA
Inspector as conformed through Manufacturer
Letter # Nil dated July 02, 2018."

Warranty
Ten (10) years extended warranty/guaranty from
the date of PAC of the first turnkey project (in
case of contract award) and from the date of
delivery (in case of direct material supply order),
as confirmed, through their letter # Nil, dated July
2, 2018 shall be applicable for all 230kV Potential
Transformers (VTs), type UTF-245 to be supplied
to SEC/National Grid SA.

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

21. 9 Page 604 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PFIFFNER INSTRUMENT Type / Model: Inductive Voltage PQ Letter:


TRANSFORMERS LTD Transformer TS&SD letter # 11-01326-02-03032301 dated
SWITZERLAND 04/12/2011, it is pre-qualified for Inductive
Rating: 110 to 230kV Voltage Transformers from110kV up to 230kV
Hirschthal , Switzerland

CONDITION:
All type, special, routine and sample tests as per
SEC specifications/ standards shall be carried
out on the first unit of Inductive Voltage
Transformers to be supplied to SEC in case of
securing an order in the presence of three (3)
SEC Engineers & one (1) approved independent
inspection agency Inspector in an independent
testing laboratory or at the manufacturer’s testing
laboratory. All the related costs for witnessing
the tests will be borne by the manufacturer. This
was confirmed by PFIFFNER Instrument
Transformers Ltd through letter #
P/900-17052011 dated 17 May 2011.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #P/900-25112010, dt: 22 mar, 2011.

21. 9 Page 605 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

RITZ Instrument Transformers GmbH Note:


GERMANY Previously " WTW (for MV CT VT) and MWB (for
HV CT VT)", the name has been changed to "
RITZ Instrument Transformers GmbH RITZ Instrument Transformers GmbH ". based on
Horner Landstrabe 302-304 their letter # Nil dated January 11,
2211 Hamburg 2018.

Location (1): Wirges


Siemensstr. 2
56422 Wirges

Location (2): Kirchaich


Muhlberg 1
97514 Oberaurach-Kirchaich

Location (3): Ottendorf


Bergener Ring 65/67
01458 Ottendorf-Okrilla

Contact Person - Dr. Ingmar Grambow,


Dr. ANdreas Grambow, Dr. Christian
Meiners
Email ID -
[email protected]
Website - www.ritz-international.com

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 11

TRANSFORMERS, CURRENT AND POTENTIAL


21. 10
POTENTIAL TRANSFORMER, (380 KV) Applicable Standards: 50-TMSS-03

21. 10 Page 606 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

HAEFELY-TRENCH ELECTRIC
SWITZERLAND

Website -
http://www.electricityforum.com/produ
cts/htg.htm

21. 10 Page 607 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Electrotecnica ARTECHE Hermanos, Innovative Systems Co. Type UTF-420 Type Test Report # PQ letter:
S.L. Ltd. 2019 04 3D 0208 Based on S&SD letter # MPQ 108011421 dated
SPAIN P.O. Box 60606, Riyadh, November 27, 2017, Electrotecnica ARTECHE
KSA Spain is pre-qualified for 380kV Potential
Plant -Mungia, Spain [email protected] Transformers (VTs) as conforming to latest
National Grid SA specification # 50-TMSS-03
Electrotecnica ARTECHE Hermanos, Rev.0 with the following conditions:
S.L.
DERIO BIDEA, 28 (Bº Zabalondo) WARRANTY:
48.100 - MUNGIA Spain Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Mungia installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - LANDER ZUGAZAGA first turnkey project in case of contract award or
& Kamal Al Muhanna date of first delivery in case of direct material
Phone - +34 94 601 1200 supply order, as confirmed by the manufacturer
Email ID - [email protected] vide letter # Nil, dated July 08, 2016.
Contact Person Email ID -
[email protected] & [email protected]
Website - www.arteche.es

ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

21. 10 Page 608 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Trench. S.A.S Siemens SA, Riyadh Note:


FRANCE CONTACT PERSON: Previously " HAEFELY-TRENCH ELECTRIC ", the
Raed Ashayer , Samer name has been changed to "
Plant -Saint-Louis, France, Eyssa, Trench. S.A.S". based on Trench. S.A.S letter #
Phone: +966 11 277 Nil dated January 01,
16 Rue Du General Cassagnoum 8662, +966 5454 70936 , 2016.
68320, Saint-Louis France Phone:
E-mail:
Contact Person - Mr. Christian Weber raed.ashayer@siemens.
Phone - + 33 389 703 594 com,, E-mail: samer.e
Email ID - [email protected]
Website -
http://www.electricityforum.com/produ
cts/htg.htm

ALSTOM (T & D) BALTEAU SA (NV)


BELGIUM

Website - http://
http://www.alstom.com/home/

NISSIN
JAPAN

Website - http://www.nissin.co.jp/e/

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 9

21. 10 Page 609 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PAD MOUNTED STATION SERVICE TRANSFORMER UP TO 2.5 MVA


22. 1
PAD- MOUNTED STATION SERVICE TRANSFORMER UP TO 2.5 MVA Applicable Standards: 51-TMSS-01

ALFANAR ELECTRICAL Type / Model: Pad Mounted Oil PQ Letter:


Saudi Arabia Immersed TS&SD letter # 11-03272-03032301 dated
16/11/2011 and S&SD letter #
Plant -Saudi Arabia Rating: 2.5MVA 14-02494-01-30504401 dt: 24/04/2014,
prequalified for Station Service Transformer up to
Po Box 301 , Riyadh 11411 ,North Righ 2.5MVA.
Road Between Exit 5 & 6
WARRANTY:
Riyadh Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Contact Person - Sultan Alghamdi " VIP installation & workmanship from the date of
key Account Manegr "; Saleh Provisional Acceptance Certificate (PAC) of the
Almehaijeen "Projects Sales Engineer " first turnkey project in case of contract award or
Phone - 920006111 date of delivery in case of direct material supply
Contact Person Email ID - order, as confirmed by ALFANAR Electrical
[email protected]; Systems (AES)–Riyadh through letter # Nil dated
[email protected] 09/04/2011.
Website - www.alfanar.com

22. 1 Page 610 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MATCO up to 2.5MVA, 36kV Type test performed PQ Letter:


Saudi Arabia on 31 August to 7
September 2016 and Based on S&SD letter # 17-02327-030504401
Plant -Riyadh 10-11 January 2018 dated July 03, 2018 MATCO, Riyadh-KSA is
in KEMA pre-qualified for Pad Mounted Station Service
Riyadh 14545 Laboratories DNV Transformers up to 2.5MVA, 36kV as conforming
AL Kharj Road Ext.12 AL-OJAMIM GL Netherlands to National Grid SA specification # 51-TMSS-01 ,
Industrial Area B.V., Arnhem, the with the following conditions:
Netherlands and the
Contact Person - Eng. Mogahed test reports number Tolerance in dimensions ( ± 3 % instead of ±
Abdullatif EL bahiy are 2269-16 dated 10%) etc. pertaining to Pad Mounted Station
Phone - +966 11 498 2122 ext. 521 24 January 2017 Service Transformers up to 2.5MVA, 36kV as per
Email ID - and 1033-18 dated revised DWG.NO.82-6180 1S2 Rev. F dated
[email protected] 13 March 2018. 12.06.2018.
Contact Person Email ID -
[email protected] Warranty:

Ten (10) years extended warranty/guarantee in


respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by MATCO, Riyadh
– KSA through their letter # Nil dated Nil.

KONCAR D&ST INC. CONDITION:


CROATIA Complete Type, Routine / Sample tests for first
Type / Model: order shall be conducted in presence of three (3)
Plant -Zagreb/ SEC/National Grid SA Engineers and one
Croatia-Hrvatskaaddress: Rating: up to 2.5MVA SEC/National Grid SA approved IIA Inspector and
all costs pertaining to the tests shall be borne by
Koncar Distribution & Special manufacturer.
Transformers D&St, J. Mokrovica 8;
P.P. 100; Hr-10090 Zagreb, Croatia WARRANTY:
Ten (10) years extended warranty/guarantee in
Contact Person - Mr. Kopjar Boris respect of defects due to design, manufacture,
Phone - +385 1 3783 728 Mob: + 385 installation & workmanship from the date of
99 2110 846 Provisional Acceptance Certificate (PAC) of the
Email ID - [email protected] first turnkey project in case of contract award or
Website - http://www.koncar-dst.hr/ date of delivery in case of direct material supply
order.

22. 1 Page 611 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FEDERAL TRANSFORMERS CO. Type / Model:


United Arab Emirates
Rating: up to 1.5MVA
Abu Dhabi , United Arab Emirates

MEMF POWER TRANSFORMER Type / Model: PQ Letter:


INDUSTRIAL COMPANY (MPT). S&SD Letters# 12-01572-2-30504401 dated May
Saudi Arabia Rating: 27, 2012 & 13-06464-1-30504401 dated
Upto 36kV, 2MVA December 11, 2013, pre-qualified for Power
Riyadh , Saudi Arabia Transformers rated up to 36KV & 2MVA.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed through Saudi Federal
Transformers L.L.C., Riyadh letter #
SFTL/TES/545/2012 dated May 05, 2012.

SAUDI TRANSFORMERS CO. Type / Model: PQ Letter:


Saudi Arabia Based on S&SD letter #
Rating: up to 33/0.4kV, up to 2.5MVA 18-00167-030504101dated June 03, 2018 The
Dammam , Saudi Arabia Saudi Transformer Co.Ltd., KSA is pre-qualified
for Pad Mounted Station Service Transformers up
Website - to 2.5MVA, 33kV as conforming to National Grid
http://www.sauditransformers.com/ SA specification # 51-TMSS-01 , with the
following conditions:

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by The Saudi
Transformer Co.Ltd., KSA through their letter #
15510277dated May 21, 2018.

22. 1 Page 612 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

UNITED TRANSFORMERS ELECTRIC Type / Model: Based on S&SD Letter # 14-010087-1-30504401


CO. (UTEC) Rating: up to 2.5MVA dated 31st December 2014, it is prequalified for
Saudi Arabia Station Service Transformer up to 2.5 MVA

Riyadh , Saudi Arabia

WESCOSA Type / Model:


Saudi Arabia
Rating: up to 13.8kV up to 2MVA only
Plant -Dammam , Saudi Arabia

First Industrial City of Dammam, P.O.


Box 2389, Dammam 31451, Saudi
Arabia

Contact Person - +966500594704


Phone - +966138100234 Ext 3267
Email ID - [email protected] ,
[email protected]
Website - http://www.wescosa.com/

ABB ELECTRICAL INDUSTRIES CO. LTD ABB Saudi Arabia, up to 2 MVA


(ABB/AEIL) Riyadh
Saudi Arabia CONTACT PERSON:
Taher Altayeb
Plant -2Nd Industrial Area, Corner No. Phone: 050548200
61, 224 Street Riyadh E-mail:
[email protected]
Saudi Arabia om

Contact Person - Mr. Naiem Sharqaui


Phone - +966-0504 206 711
Email ID - [email protected]
Website - http://www.abb.com.sa/

Total = 9

TRANSFORMER, SPECIALTY
23. 1
GROUNDING TRANSFORMER, 13.8KV, 33KV OR 34.5KV Applicable Standards: 52-TMSS-01

23. 1 Page 613 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES


CORPORATION (HICO)
SOUTH KOREA

Plant -Republic of Changwon, Korea

Eric Rhie, 450, Gongdeok-Dong,


Mapo-Gu, Seoul , Korea
Tel:82-707-6180

Contact Person - Mr. Jason Kang; Sale


Manager & Mr. Young Kim; Sales
Manager
Contact Person Email ID -
[email protected] ,
[email protected]
Website -
http://www.hyosung.co.kr/eng/index.js
p?, www.hyosung.com

CROMPTON GREAVES SUSPENDED FOR SEC 2005 PROJECTS AND


INDIA ONWARD

Website - http://www.cglonline.com/

HD Hyundai Electric Co., Ltd


SOUTH KOREA Previously Hyundai Heavy Industries Co. Ltd [The
name has been changed based on P&SFD letter
Plant -Ulsan #17-04234/01-030504401 dated May 24, 2017].

1000, Bangeojinsunhwan-doro, Previously Hyundai Electric & Energy Systems


Dong-gu, Ulsan, South Korea, Co., Ltd., the name has been changed to HD
Hyundai Electric Co., Ltd
Ulsan

Contact Person - Mr. J.W(Jin) Lee


Phone - +966-11-293-2026,
+82-10-4818-0822
Contact Person Email ID -
[email protected]
Website -
http://www.hyundaielectric.com

23. 1 Page 614 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CG POWER SYSTEMS On Hold


BELGIUM

Website - http://www.pauwels.com/

Total = 4

TRANSFORMER, SPECIALTY
23. 2
AIR CORE NEUTRAL GROUNDING REACTOR FOR 11 KV THROUGH 132 KV SYSTEM Applicable Standards: 52-TMSS-02

Total = 1

POWER TRANSFORMERS
24. 1
Power Transformer rated up to 100 MVA Applicable Standards: 53-TMSS-01

24. 1 Page 615 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ELPROM Heavy Industries Type / Model: for Power Transformers Based on TS&SD letter # 11-00438-03-03032301
Bulgaria dated 15/05/2011, it is prequalified for Power
Rating: 132kV, 100MVA Transformers up to 132kV, 100MVA as
Plant -Sofia, Bulgaria confirming to SEC specification # 53-TMSS-01,
Rev.0 with the following conditions:
• All type, special, routine and sample tests as
per SEC specifications/standards for Power
Transformers up to 132kV, 100MVA shall be
carried out in case of contract award or SEC
direct purchase order at SEC approved
independent laboratory or at manufacturer’s
testing laboratory in presence of three (3) SEC
Engineers and one (1) SEC approved
independent inspection agency. All the related
costs for witnessing of the tests will be borne by
the manufacturer. This was confirmed by HHI–
Bulgaria through letter # D-0353 dated
20/08/2010.
• Ten (10) years extended warranty from the
date of PAC of the turnkey project in case of
contract award or date of delivery in case of
direct material supply order. This was confirmed
by HHI–Bulgaria through letter # D-0355 dated
20/08/2010.

Previously "Hyundai Heavy Industries Co."

24. 1 Page 616 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PJSC ZAPOROZHTRANSFORMATOR Type / Model: Power Transformers Based on S&SD letter# 13-07568-30504401
(ZTR) dated December 31, 2013, it is pre-qualified for
Ukraine Rating: 132kV, 100MVA Power Transformers rated up to 100MVA, 132
kV as conforming to National Grid SA
Plant -Zaporizhia , Ukraine specification # 53-TMSS-01, Rev.01, with the
following conditions:
• All Type, Special & Routine tests as per latest
National Grid SA Specifications/Standards & IEC
requirements together (with Thermal & Dynamic
short-circuit calculations per IEC 60076-5) shall
be carried out on the next unit to be supplied to
SEC/ National Grid SA in an Accredited Testing
Laboratory in the presence of three (3) National
Grid SA Engineers & one (1) National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter
1/115-2261 dated August 15, 2011.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
in writing by the manufacturer through their letter
# 1/115-2266 dated August 15, 2011.

24. 1 Page 617 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS ENERGY (DRESDEN) Type / Model: Power Transformer Previously Name SIEMENS AG (Dresden)
GERMANY
Rating: up to 230kV, 200MVA Prequalified Power Transformer up to 230kV
Website - http://www.simense.com PRIMARY, 200MVA

based on TS&SD letter# 09-01501-03032301


dated 25th May 2009 , Siemens AG from
Germany-Dresden for Power Transformer up to
230kV, 200MVA as confirming to SEC
specification # 53 TMSS-01, rev.0 & 53-TMSS-02,
rev.0 with the following conditions:

• All type, special & routine tests for each voltage


class as per SEC specifications/standards shall
be carried out on the first batch to be supplied to
SEC in securing an order in the presence of three
(3) SEC engineers & one (1) approved
independent inspection agency Inspector.

• Ten (10) years extended warranty/guarantee in


respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award
or date of delivery in case of direct material
supply order.

24. 1 Page 618 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd


SOUTH KOREA Previously Hyundai Heavy Industries Co. Ltd [The
name has been changed based on P&SFD letter
Plant -Ulsan #17-04234/01-030504401 dated May 24, 2017].

1000, Bangeojinsunhwan-doro, Previously Hyundai Electric & Energy Systems


Dong-gu, Ulsan, South Korea, Co., Ltd., the name has been changed to HD
Hyundai Electric Co., Ltd
Ulsan

Contact Person - Mr. J.W(Jin) Lee


Phone - +966-11-293-2026,
+82-10-4818-0822
Contact Person Email ID -
[email protected]
Website -
http://www.hyundaielectric.com

24. 1 Page 619 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ILJIN ELECTRIC CO. LTD. META Switchgear Type / Model: for Power Transformers PQ Letter:
SOUTH KOREA Company Based on S&SD Letter # 12-03077-30504401
(Branch of MEMF Rating: 230kV, 166.7MVA dated
905-17, Mannyeon-ro, Hwaseong-si, Electrical Industries co) September 15, 2012 and S&SD letter
Gyeonggi, KOREA 2nd New Industrial Area #15-02407-02-30504401 dated June 23, 2015.
P.O. Box: 355988, ILJIN ELECTRIC Co. Ltd – Hongseong city, Korea
Contact Person - Mr. Jeong Kyung Woo Riyadh 11383 is prequalified for Power Transformers up to 230
, Mr. Jaeho Kim Kingdom of Saudi Arabia kV, 166.7 MVA as conforming to
Phone - +82-2-707-9161 SEC/National Grid SA Specification # 53-TMSS-01
Contact Person Email ID - Mr.Ahmed Elafifi with the following conditions:
[email protected] , [email protected] +966536024245
Website - http://www.iljinelectric.co.kr [email protected] CONDITION:
.sa All Type, Routine and Special tests as per
SEC/National Grid
SA Specifications shall be conducted on the
proposed Power Transformers in the
Manufacturer's Testing Laboratory in the
presence of three (3) SEC/National Grid SA
Engineers & one (1) SEC/National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #
IL2014-11-05-01 dated November 5, 2014.

WARRANTY:
Ten (10) years extended Warranty for the
proposed Power Transformers in respect of the
defects due to design, manufacturing, installation
and workmanship from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) and from the date of
delivery for the direct material supply order as
confirmed through the manufacturer letter # Nil
dated November 5, 2014

24. 1 Page 620 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ELEKTRIK SANAYI A.S. ABB Saudi Arabia, Type / Model: ZTR CONDITION:
[PREVIOUSLY ABB ESAS] Al-Khobar Pre-Qualification & Participation for current &
TURKEY CONTACT PERSON: Rating: 132kV, 100MVA future SEC's Projects subjected to the mutual
Rasim Duran agreement between SEC & ABB dated 09 March
Plant Phone: 0554446258 2009
-Turkey-Istanbul/Kartaladdress:Esentep [email protected]
e Mahallesi, Milangaz Cad m

Esentepe Mahallesi, Milangaz Cad No.


52 Kartal 34870, Istanbul -Turkey

Contact Person - Mr. Sezgin Perdahci


Phone - +90-533-666-8067
Email ID - E-mail :
[email protected]
Website - http://www.abb.com

CG POWER SYSTEMS On Hold


BELGIUM

Website - http://www.pauwels.com/

LIAONING - EFACEC ELECTRICAL Rating: Based on S&SD Letter 12-01675-30504401 dated


EQUIPMENT CO., LTD (LEEEC) Up to 100MVA May 20, 2012. It is prequalified for Power
CHINA Transformers rated up to 100 MVA as conforming
to SEC Specification# 53-TMSS-01 with the
Liaoning Province , China following condition:
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
in writing by Liaoning - Efacec Electrical
Equipment Co., Ltd (LEEEC) through their letter #
Nil dated April 18, 2012.

24. 1 Page 621 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SAUDI POWER TRANSFORMERS Type / Model: Power Transformers Type Test Certificate PQ Lettter:
COMPANY (SPTC) #B6003867 dated 24 Based on S&SD Letter # 15-04608-03-30504401
Saudi Arabia 100 MVA, 132 kV February 2017 dated August 18, 2015, It is prequalified for
Power Transformers up to 132 kV, 100 MVA,
Plant -Dammam-Saudi Arabia
CONDITION:
Po Box 6140 Dammam 32232, Building
No. 4292 Unit No. 19 , Saudi Arabia WARRANTY:
Mr. Hosam Al Shaikh, CEO Ten (10) years extended Warranty for the
Phone: +966 13 814 4622 ext 111 proposed Power Transformers rated up to 132
Fax. +966 13 814 4627 kV, 100 MVA in respect of the defects due to
Mobile: +966 50 680 3900 design, manufacturing, installation and
workmanship from the date of the Provisional
Mr. Bahaa Abduieh, Sales & Marketing Acceptance Certificate (PAC) of the project (in
Manager case of contract award) and from the date of
Phone: + +966 13 814 4622 ext 133 delivery for the direct material supply order as
Fax. +966 13 814 4627 confirmed through the manufacturer letter# CEO
Mobile: +966 50 0082841 /2015 /008 dt:Aug 8, 2015.

Email ID - [email protected],
[email protected]

24. 1 Page 622 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Green Transfo Energy Turkey Enerji RADYA International Type / Model: Power Transformers Pre-qualified for Power Transformers rated up to
Endustrisi ve Ticaref Anonim sirketi EASTERN RING BRANCH 132kV, 67MVA
TURKEY ROAD Rating: 132kV, 67 MVA Based on S&SD letter# 14-02364-1-30504401
AR RAYYAN, RIYADH dated April 01, 2014, it is pre-qualified for Power
Plant -Cayirova-Kocaeli-Turkey 11575 Transformers up to 67 MVA and, 132 kV
EXIT 14, RIYADH conforming to National Grid SA specification
Tosb Organize Sanayi Bölgesi (OSB) P.O. BOX 61891 53-TMSS-01, Rev. 01, with the following
Mah.2 Cad No:6-1 Çayırova Kocaeli KINGDOM OF SAUDI conditions:
ARABIA • All Type, Special & Routine tests as per National
Contact Person - Mr.Govindaraj TEL: 00966 11 4966667 Grid SA Specifications/Standards shall be carried
SETHURAMAN, Mr.Ufuk Dogan out on the first unit to be supplied to National Grid
Contact Person Email ID - CONTACT PERSON: ASIF SA in the manufacturer Testing
govindaraj.sethuraman@green-transfo. NOORUOOIN SARANG Laboratory in the presence of three (03) National
com ,[email protected] Phone: 0504799504 Grid SA Engineers & one (01) National Grid SA
Email: approved Independent Inspection Agency (IIA)
[email protected] Inspector. All costs of which shall be borne by
om.sa the manufacturer. This was confirmed in writing
by the manufacturer through their letter #
MKT_132KV Trafo_005, dated June 18, 2013.
• Schneider Electric Transformer Factory -
Cayirova, Istanbul, Turkey has confirmed that
“improvement needs implementation will be
complied during the FAT for the first transformer
order” confirmed through letter # MKT_132KV
Trafo_010 dated February 12, 2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) or from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter # MKT_132KV Trafo_007-1 dated March
19, 2014.
- Previously "AREVA-Turkey", the name has been
changed to Schneider Electric-Turkey based on
Schneider Electric letter # MKT-18.01.11 dated
18/01/2010 and AREVA T&D letter #
BF/BL25.11.2010.

24. 1 Page 623 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GETRA POWER S.P.A Type / Model: Power Transformer Based on S&SD Letter # 14-04523-01-03504401
ITALY dated 7th July 2014, it is pre-qualified for Power
Rating: 132kV , 100MVA Transformer up to 100MVA, 132kV as confirming
Plant -Plant Location : Marcianise (Ce) , to National Grid SA specification # 53-TMSS-01,
Italy Rev.01 with the following conditions:
• All Type, Special & Routine tests as per National
Grid SA Specifications/Standards shall be carried
out on the first unit to be supplied to National Grid
SA in an Approved Independent
Testing Laboratory and/or in the manufacturer’s
Testing Laboratory in the presence of three (03)
National Grid SA Engineers & one (01) Approved
Independent Inspection Agency (IIA) Inspector.
All the costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the
manufacturer through their letter #
GPJLT/SECNG/SSD/009, dated 8th June 2014.
• WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter # GPJLT/SECNG/SSD/0010 dated 8th
June 2014.

24. 1 Page 624 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR D&ST INC. Type / Model: Power Transformer Pre-qualified for Power Transformers rated up to
CROATIA 132kV, 67MVA
Rating: 132kV, 67MVA
Plant -Zagreb/ Based on S&SD Letter # 14-03217-1-30504401
Croatia-Hrvatskaaddress: dated May 18, 2014, it is pre-qualified for Power
Transformer up to 67MVA, 132kV as confirming
Koncar Distribution & Special to National Grid SA specification # 53-TMSS-01,
Transformers D&St, J. Mokrovica 8; Rev.01 with the following conditions:
P.P. 100; Hr-10090 Zagreb, Croatia • All Type, Special & Routine tests as per National
Grid SA Specifications shall be carried out on the
Contact Person - Mr. Kopjar Boris first unit to be supplied to National Grid SA in the
Phone - +385 1 3783 728 Mob: + 385 Approved Independent Testing Laboratory or in
99 2110 846 the manufacturer’s Testing Laboratory in
Email ID - [email protected] presence of three (03) National Grid SA
Website - http://www.koncar-dst.hr/ Engineers & one (01) Approved Independent
Inspection Agency (IIA) Inspector. All the costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil, dated May 04, 2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) and from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter # Nil dated May 04, 2014.

24. 1 Page 625 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MITSUBISHI Mitsubishi Electric Saudi ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN Ltd.Power T&D Division. DURING APRIL 2005.
Contact
Plant -T&D Systems, Center, Ako City Person:Mr.Tomonori
/Japan. Umiyama,P.O.Box
2391,Riyadh 11451
Mitsubishi Electric Corporation Tdsc, Phone -
Ako Marketing Section, 651 Tenwa, +966-55-547-5316
Ako City,Hyogo, 678-0256,Japan Email -
[email protected]
Contact Person - Mr. Mikinori Arimoto
Phone - +81-791-46-2122
Email ID -
[email protected].
co.jp
Website -
http://global.mitsubishielectric.com/

SC ELECTROPUTERE SA Type / Model: Power Transformer ON HOLD for the procurement of Power
Romania Transformer for all ongoing and forthcoming
Rating: 132kV, 100MVA projects of company including the Eight (8) spare
Plant -Craiova, Romania transformers against purchase order #
4500217223 as per S&SD fax#
16-05458-30504401 dated 23/06/2016.

Based on TS&SD letter # 11-002054-1-03032300


dated10/7/2011, it is prequalified for Power
Transformer up to 132kV, 100MVA, as
conforming to National Grid SA specification #
53-TMSS-01, Rev.0 with the following condition:

• Ten (10) years extended warranty from the


date of PAC of the first turnkey project (in case
of contract award) or date of first delivery in
case of direct material supply order. This was
confirmed by SC Electroputere SA through letter
27500 dated 14/06/2010.

AREVA
GERMANY

Website - http://www.areva.com/

24. 1 Page 626 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BEST Type / Model: Power Transformer Based on TS&SD Letter # 06-789-03032300


TURKEY dated July 25, 2006, it is pre-qualified for Power
Rating: 132kV, 100MVA Transformer up to 100MVA, 132kV as confirming
Plant -Turkey-Balikesir (Asb Factory) to National Grid SA specification #53-TMSS-01,
Rev.01 with the following conditions:
Website - Ten (10) years extended warranty from the date
http://www.besttrafo.com.tr/en/index.h of PAC of the first turnkey project (in case of
tml contract award) and from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter # EAI-2301061500 dated January 23, 2006.

Ganz Transformers, Motors, and Type / Model: Power Transformers Previously CG [The name has been changed
Generators LTD. based on letter # 21-00289-30504401 dated 28
HUNGARY Rating: 132kV, 100MVA February 2021].

Györgyei út 14-22. Based on TS&SD Letter 11-01981-1-03032301


2766 Tápiószele dated July 11, 2011, it is pre-qualified for Power
Hungary Transformers rated up to 132kV/100MVA as
1051 Budapest, Sas utca 1. II. em. 1. conforming to SEC Specification #53-TMSS-01,
Rev.0, with the following condition:
Budapest • Ten (10) years extended warranty from the
date of PAC of the first turnkey project in case of
Contact Person - Mohammed Sobuh contract award or date of first delivery in case of
Phone - +36 1 483 6600 direct material supply order. This was confirmed
Email ID - [email protected] in writing by the manufacturer through their letter
Contact Person Email ID - # Nil dated June 15, 2010.
[email protected]
Website - www.ganzelectric.com

24. 1 Page 627 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EFACEC ENERGIA MAQUINAS E 132kV, 100MVA Pre-qualified for Power Transformers rated up to
EQUIPAMENTOS ELECTRICOS, S.A 132kV, 100MVA
PORTUGAL

Plant -Porto/Portugal

Parque Empresarial Da Arroteia


(Poente), Apartado 1018 4468-952 S.
Mameda De Infesta- Portugal

Contact Person - Mr. Abílio Rodrigues: :


+351 968331386;+351 229562300, Mr.
Filipe Vila Real: +351 939236215; +351
229562300
Email ID - Metal Clad Switchgears: :
[email protected];
[email protected] & Power
Transformers:
:[email protected];
[email protected]
Website -
http://www.efacec.pt/en/switchgear/
&
http://www.efacec.pt/en/transformers/

24. 1 Page 628 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR POWER TRANSFORMERS Type / Model: Power Transformer Based on S&SD Letter # 14-08041-01-03504401
LTD dated 13/02/2014 & 14-08041-02-03504401
CROATIA Rating: up to 132kV, 100MVA dated 25/03/2014, it is pre-qualified for Power
Transformer up to 100MVA, 132kV as confirming
Plant -Josipa Mokrovica 6 to National Grid SA specification # 53-TMSS-01,
Rev.01 with the following conditions:
10 090 Zagreb, Coratia • All Type, Special & Routine tests as per National
Grid SA Specifications/Standards shall be carried
Contact Person - Mr. Ivan Milcic, GM out on the first unit to be supplied to National Grid
Phone - +385 1 3795 555 SA in the Approved Independent Testing
Laboratory or in the manufacturer’s Testing
Laboratory in presence of three (03) National
Grid SA Engineers & one (01) Approved
Independent Inspection Agency (IIA) Inspector.
All the costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter # Nil, dated
01-04-2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) or from the date of first
delivery in case of direct material supply order,
as confirmed by the manufacturer through their
letter # 2014/02, dated 01-04-2014 dated April 06,
2014

Siemens Energy Austria GmbH


AUSTRIA

Weiz , Austria

Website - http://www.vatechetg.at/

24. 1 Page 629 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GRID SOLUTIONS ENERJI ENDUSTRISI SUSPENDED for all SEC/National Grid SA ongoing
ANONIM SIRKETI and forthcoming projects based on VP,
TURKEY Engineering letter # 19-00366-30504401 dated
February 17, 2019.

New Remark
Previously ALSTOM GRID, GEBZE.

Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].

HYOSUNG HEAVY INDUSTRIES


CORPORATION (HICO)
SOUTH KOREA

Plant -Republic of Changwon, Korea

Eric Rhie, 450, Gongdeok-Dong,


Mapo-Gu, Seoul , Korea
Tel:82-707-6180

Contact Person - Mr. Jason Kang; Sale


Manager & Mr. Young Kim; Sales
Manager
Contact Person Email ID -
[email protected] ,
[email protected]
Website -
http://www.hyosung.co.kr/eng/index.js
p?, www.hyosung.com

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

24. 1 Page 630 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HITACHI LTD Rating - Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com

Contact Person - Mr. Anders L


katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

24. 1 Page 631 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS ENERGY (NURNBERG) Previously Name SIEMENS AG (NURNBERG)


GERMANY

Plant -NURNBERG

Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx

24. 1 Page 632 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd Hitachi Energy Rating up to 132kV, 100MVA PQ Letter


ITALY King Fahad Road Legend Based on S&SD letter # MPQ996211924 dated
Tower March 05, 2024, the manufacturer is prequalified
Plant -Monselice Riyadh, Saudi Arabia for Power Transformer rated up to 132kV,
100MVA as confirming to National Grid SA
ABB POWER GRIDS ITAL - Via Hatem, Alazzam specification # 53-TMSS-01, with the following
Campestrin 6A Monselice +966112181777 ext conditions:
5725 or +966560955437
Contact Person - Facco Eddy; Luciano hatem.alazzam@hitachie TYPE TEST:
Femminis nergy.com All type/ special/routine tests as per SEC/National
Contact Person Email ID - Grid SA Standards/Specifications shall be
[email protected]; Haja Shariff, PGTR conducted on the offered product in an
[email protected] Transformers, +966 accredited test lab in the presence of three (03)
om 112181777 or SEC/National Grid SA engineers and one (01)
Website - +966561661385, SEC/National Grid SA approved 3rd party
https://www.hitachiabb-powergrids.co haja.shariff1@hitachiene Independent Inspection Agency (IIA) inspector
m/ rgy.com during first project awarded. All cost of which
shall be borne by the manufacturer. This was
confirmed in writing by the manufacturer through
their letter Ref. # Nil dated 06, July 2021.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for Power Transformer in
respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # Nil dated 06, July 2021.

24. 1 Page 633 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Voltamp Power SAOC Rating up to 132kV, 100MVA PQ Letter


Oman Based on S&SD letter # 23-02545-01-30504401
dated November 30, 2023, the manufacturer is
Plant -Phase 5, Suhar Industrial Estate prequalified for Power Transformer rated up to
132kV, 100MVA as confirming to National Grid SA
Po Box : 690 , Postal code 322 specification # 53-TMSS-01, with the following
conditions:
Suhar
TYPE TEST:
Contact Person - Ali Al Abduwani / All type/ special/routine tests as per SEC/National
Yousuf Al Shafey Grid SA Standards/Specifications shall be
Phone - +968 24441200 / +968 conducted on the offered product in an
26947901 accredited test lab in the presence of three (03)
Email ID - [email protected] SEC/National Grid SA engineers and one (01)
Contact Person Email ID - SEC/National Grid SA approved 3rd party
[email protected] Independent Inspection Agency (IIA) inspector
Website - https://voltampoman.com/ during first project awarded. All cost of which
shall be borne by the manufacturer. This was
confirmed in writing by the manufacturer through
their letter Ref. # GM/NG SE/01/2023 dated 01,
June 2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for Power Transformer in
respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # Nil dated 01 February, 2023.

24. 1 Page 634 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Zhongshan transformer Hitachi Energy Rating up to 132KV, 100MVA PQ Letter
Company Ltd King Fahad Road Legend Based on S&SD letter # 23-01516-01-30504401
CHINA Tower dated August 16, 2023, the manufacturer is
Riyadh, Saudi Arabia prequalified for Power Transformer rated up to
Plant -China 132KV, 100MVA as confirming to National Grid
Hatem, Alazzam SA specification # 53-TMSS-01, with the
No. 1 Hai Cheng North Road. Hengmen Transformers Market following conditions:
Nanlang Town. Guangdong. Manager
+966112181777 ext TYPE TEST:
Zhongshan 5725 or +966560955437 All type/ special/routine tests as per SEC/National
, Grid SA Standards/Specifications shall be
Contact Person - Mr. Owen Wenhao hatem.alazzam@hitachie conducted on the proposed Power Transformers
Ou ; Ms. Morgen-GuiFang Zhong nergy.com in Zhongshan Factory laboratory in the presence
Phone - (86 760) 87853652 of three (03) SEC/National Grid SA engineers and
Contact Person Email ID - Haja Shariff, PGTR one (01) SEC/National Grid SA approved 3rd
[email protected] Transformers, +966 11 party Independent Inspection Agency (IIA)
; 2181777 or inspector during first project awarded. All cost of
morgen-guifang.zhong@hitachienergy. +966561661385, which shall be borne by the manufacturer. This
com haja.shariff1@hitachiene was confirmed in writing by the manufacturer
Website - www.hitachienergy.com rgy.com through their letter # Nil dated 24.07.2023

WARRANTY
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered Power
Transformer rated up to 132KV, 100MVA in
respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # Nil dated 25.07.2023

24. 1 Page 635 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens Energy Transformer (Wuhan) Siemens Energy Limited Power Transformers up to 132kV and PQ Letter
Co., Ltd Saudi Arabia up to 100MVA Based on S&SD letter #23-001178/01-30504401
CHINA Business Gate, Building dated June 21, 2023, the manufacturer is
C-1, Airport Road, prequalified for Power Transformer rated up to
Plant -Wuhan, China Qurtubah District. P.O. 132kV, 100MVA, as confirming to National Grid
Box 39582, Riyadh SA specification # 53-TMSS-01, with the
No.1 Jingyang Avenue, Yangluo 11489, Saudi Arabia following conditions:
Economic Development Zone, Wuhan, +966566375966
P.R.China kaisar.langoo@siemens- TYPE TEST:
energy.com All Type, Routine and Special tests as per
Wuhan SEC/National Grid SA Specifications shall be
conducted on the proposed Power Transformers
Contact Person - 1st Contact: Ms. in the Manufacturer's Testing Laboratory in the
Wang Fei - Karen, 2nd Contact: Mr. Tao presence of three (3) SEC/National Grid SA
Cong Xue Engineers & one (1) SEC/National Grid SA
Phone - +86 (27) 89669877 approved Independent Inspection Agency (IIA)
Email ID - Inspector. All costs of which shall be borne by
[email protected] the manufacturer. This was confirmed in writing
Contact Person Email ID - 1st Contact: by the manufacturer through their letter # Nil
[email protected] , dated December 22, 2021.
2nd Contact:
[email protected] WARRANTY
Website - www.siemens-energy.com Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered Power
Transformer rated up to 132kV, 100MVA in
respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # Nil dated December 22, 2021.

24. 1 Page 636 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TBEA Shenyang Transformer Group ESNAD ELBENA Power Transformers up to 380kV and PQ Letter:
Co., Ltd. CONSTRUCTION 502MVA Based on S&SD letter # 23-01799-01-30504401
CHINA COMPANY dated September 13, 2023, the manufacturer is
2601 King Abdullah prequalified for 380KV Power Transformer rated
Plant -China-Shenyang Road, Qudus up to 502MVA and Oil Immersed Reactor rated up
Neighborhood, Riyadh to 380kV as confirming to National Grid SA
No.32 Kaifa Blvd, Economic and 13214 - 8401. specification # 53-TMSS-01 and 58-TMSS-01,
Technological Development Zone, +966 594 000 333 with the following conditions:
Shenyang City, Liaoning Province, [email protected]
China m TYPE TEST:
All type/ special/routine tests as per SEC/National
Shenyang Grid SA Standards/Specifications shall be
conducted on the offered product in an
Contact Person - Jia Wei accredited test lab in the presence of three (03)
Phone - 0086 24 25698188 /+966 SEC/National Grid SA engineers and one (01)
558458177 SEC/National Grid SA approved 3rd party
Email ID - [email protected] Independent Inspection Agency (IIA) inspector
Contact Person Email ID - during first project awarded. All cost of which
[email protected] shall be borne by the manufacturer. This was
Website - http://www.tbea.com.cn confirmed in writing by the manufacturer through
their letter Ref. # Nil dated 31.08.2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the 380kV Transformer,
132kV Transformer and Shunt Reactor in respect
of the defects due to design, manufacturing,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
or from the date of first delivery (in case of
direct material supply order), as confirmed by the
manufacturer, through their Letter Ref. # Nil dated
31.08.2023.

Total = 32

POWER TRANSFORMERS
24. 2
Power Transformer rated above 100 MVA Applicable Standards: 53-TMSS-01

24. 2 Page 637 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CG POWER SYSTEMS On Hold


BELGIUM

Website - http://www.pauwels.com/

Siemens Energy Austria GmbH


AUSTRIA

Weiz , Austria

Website - http://www.vatechetg.at/

SIEMENS ENERGY (DRESDEN) Type / Model: Power Transformer Previously Name SIEMENS AG (Dresden)
GERMANY
Rating: up to 230kV, 200MVA Prequalified for Power Transformer up to 230kV,
Website - http://www.simense.com 200MVA

based on TS&SD letter# 09-01501-03032301


dated 25th May 2009 , Siemens AG from
Germany-Dresden for Power Transformer up to
230kV, 200MVA as confirming to SEC
specification # 53-TMSS-01, rev.0 &
53-TMSS-02, rev.0 with the following conditions:
• All type, special & routine tests for each voltage
class as per SEC specifications/standards shall
be carried out on the first batch to be supplied to
SEC in securing an order in the presence
of three (3) SEC engineers & one (1) approved
independent inspection agency Inspector.
• Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award
or date of delivery in case of direct material
supply order.

24. 2 Page 638 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB CORDOBA ABB Saudi Arabia, Type / Model: Power Transformer Prequalified for power transformer up to 500
SPAIN Al-Khobar MVA
CONTACT Rating: up to 380kV, 500MVA
Plant -Cordoba, Spain PERSON:Rasim Duran Based on TS&SD letter#
Phone - 0554446258 09-F011657/03-03032301 dated August 16, 2009.
Escritor Conde Zamorea, S/N ,14004 Email - It is pre-qualified for Power Transformer up to
Cordoba (Spain) [email protected] 380kV, 500MVA as confirming to SEC
m specification # 53-TMSS-02, rev.0 with the
Contact Person - Mr. Evan Smith following conditions:
Phone - +34608749306 • All type, design, special (exclude Short-Circuit
Email ID - [email protected] Test) & routine tests as per SEC
Website - Specifications/Standards together with Thermal &
http://new.abb.com/products/transform Dynamic short-circuit calculations per IEC
ers 60076-5 shall be carried out on the first unit to be
supplied to SEC in an accredited Independent
Testing Laboratory or in the manufacturer 's
testing laboratory in the presence of three (3)
SEC Engineers & one (1) SEC approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter #
PPTR-002.2 dated February 14, 2009 and the
submitted "Confirmation Letter" # Nil dated
November 18, 2008. [this condition has been
modified based on S&SD letter#
12-0395-01-30504001 dated February 12, 2012]

• Seven (7) years extended warranty from the


date of PAC of the First turnkey project in case of
contract award or date of the First delivery in
case of direct material supply order. This was
confirmed in writing by the manufacturer through
their submitted "Guarantee/Warranty Certificate"
# Nil dated May 25, 2009.

24. 2 Page 639 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd


SOUTH KOREA Previously Hyundai Heavy Industries Co. Ltd [The
name has been changed based on P&SFD letter
Plant -Ulsan #17-04234/01-030504401 dated May 24, 2017].

1000, Bangeojinsunhwan-doro, Previously Hyundai Electric & Energy Systems


Dong-gu, Ulsan, South Korea, Co., Ltd., the name has been changed to HD
Hyundai Electric Co., Ltd
Ulsan

Contact Person - Mr. J.W(Jin) Lee


Phone - +966-11-293-2026,
+82-10-4818-0822
Contact Person Email ID -
[email protected]
Website -
http://www.hyundaielectric.com

24. 2 Page 640 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ILJIN ELECTRIC CO. LTD. META Switchgear Power Transformers 380kV, Up to PQ Letter
SOUTH KOREA Company 502MVA
(Branch of MEMF Based on S&SD letter #23-0434/01-30504401
905-17, Mannyeon-ro, Hwaseong-si, Electrical Industries co) dated March 06, 2023, the manufacturer is
Gyeonggi, KOREA 2nd New Industrial Area prequalified for Power Transformers 380kV,
P.O. Box: 355988, above 100MVA as confirming to National Grid SA
Contact Person - Mr. Jeong Kyung Woo Riyadh 11383 specification #53-TMSS-01, with the following
, Mr. Jaeho Kim Kingdom of Saudi Arabia conditions:
Phone - +82-2-707-9161
Contact Person Email ID - Mr.Ahmed Elafifi CONDITION
[email protected] , [email protected] +966536024245
Website - http://www.iljinelectric.co.kr [email protected] Fresh Type, Routine and Special tests shall be
.sa conducted on the proposed Power Transformer
in the first project as per IEC and SEC/National
Grid SA requirement in an accredited test lab /or
in manufacturer’s testing laboratory, in presence
of three (3) SEC/National Grid SA Engineers &
one (1) SEC/National Grid SA approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
ILJIN – Korea through their letter Ref. #
IJ20220414-1, dated April 14, 2022.

WARRANTY

Ten (10) years extended warranty/guarantee to


SEC/National Grid SA for the offered power
transformers in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # IJ20220414-3, dated
April 14, 2022.

24. 2 Page 641 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ELEKTRIK SANAYI A.S. ABB Saudi Arabia, Type / Model: Power Transformer Prequalified for power transformer up to 250 MV
[PREVIOUSLY ABB ESAS] Al-Khobar only
TURKEY CONTACT Rating: 380kV, 250MVA
PERSON:Rasim Duran Based on S&SD letter# 14-02898/03-030504401
Plant Phone - 0554446258 dated June 17, 2014, it is pre-qualified for Power
-Turkey-Istanbul/Kartaladdress:Esentep Email - Transformer up to 380kV, 250MVA as confirming
e Mahallesi, Milangaz Cad [email protected] to National Grid SA specification # 53-TMSS-02,
m Rev.01 with the following conditions:
Esentepe Mahallesi, Milangaz Cad No.
52 Kartal 34870, Istanbul -Turkey • All Type, Routine and Special testes as per NG
Specifications/Standards and IEC requirement
Contact Person - Mr. Sezgin Perdahci together with Thermal & Dynamic short-circuit
Phone - +90-533-666-8067 calculations per IEC 60076-5 shall be carried out
Email ID - E-mail : on the First unit to be supplied to SEC/NG of
[email protected] Power Transformers in the Manufacturer's
Website - http://www.abb.com Testing
Laboratory in the presence of three (3) SEC/NG
Engineers & one (1) SEC/ NG approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter # Nill dated
February 04, 2013 .
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) and from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter #Nill dated May 24, 2013.

AREVA
GERMANY

Website - http://www.areva.com/

24. 2 Page 642 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MITSUBISHI ELECTRIC CORPORATION Type/Model - Shell type ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.

Plant -T&D Systems Center, Amagasaki


City, Japan

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

24. 2 Page 643 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BEST , (OSB FACTORY) 230kV & 380KV upto 500MVA PQ Letter:


TURKEY Based on S&SD letter # 16-06868/04-030504401
dated December 26,2016, BEST A.S, Balikesir
Plant -Turkey-Balikesir (Osb Factory) (OSB Plant) Turkey is pre-qualified for Power
Transformers 230KV & 380KV up to 500MVA as
Contact Person - Mr. A. T. Haydar conforming to National Grid SA specification #
Sargin- General Manager ; Mr. Mehmet 53-TMSS-02 Rev.01, with the following
ASLAN- Area Sales Manager conditions:
Contact Person Email ID -
[email protected] ; TYPE TEST:
[email protected] Type/special & routine tests shall be conducted
on 230 KV & 380 KV Power Transformers rated
up to 500 MVA in presence of three SEC/National
Grid SA Engineers and third party inspector at
Manufacturer’s accredited laboratory for the first
projects or first purchase order at the sole
expenses of the manufacturer as confirmed
through their letter# BEST-100316-SEC-02 dated
10 March 2016.

WARRANTY:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) and date of first delivery (in
case of direct material supply order), as
confirmed, through their Letter No.
BEST-100316-SEC-01 dated 10 March 2016.

24. 2 Page 644 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KONCAR-POWER TRANSFORMERS, Siemens Ltd.- Saudi up to 380kV & 500MVA Previously Name KONCAR POWER
Croatia (A joint Venture of Siemens Arabia TRANSFORMERS LTD. (A joint venture of
Energy and Koncar) Siemens Ltd., 02nd floor, Siemens and KONCAR)
CROATIA Juffali Tower , P.O
Box#719, Al-Khobar Based on S&SD letter # 17-03229-05-30504401
Josipa Mokrovica 12, 10090 Zagreb 31952, Kingdom of Saudi dated May 17, 2017, Koncar Power
Arabia Transformers Ltd, Croatia (A joint Venture of
Contact Person - Mr. Nidzar +966 (13) 865 9680 Siemens and Koncar) is pre-qualified for Power
Turcinhodzic Kaisar.langoo@siemens. Transformer rated up to 380kV & 500MVA as
Phone - +38513794075 com conforming to National Grid SA specification #
Email ID - [email protected] 53-TMSS-01, with the following conditions:
Contact Person Email ID -
[email protected] •Ten (10) years extended warranty from the date
Website - http://www.koncar-dst.hr/ of PAC of the project (in case of contract award)
or date of delivery (in case of direct material
supply order), as confirmed, through their Letter
No. NIL dated June 6, 2016 shall be applicable for
all Power Transformers rated up to 380kV &
500MVA to be supplied to SEC/National Grid SA.

•All type, design, special & routine tests as per


SEC Specifications/Standards shall be carried out
on Power Transformers rated up to 380kV &
500MVA in manufacturer's accredited testing
laboratory for the first project or first purchase
order in the presence of three (3) SEC Engineers
& one (1) SEC approved Independent Inspection
Agency (IIA) Inspector. All costs of which shall
be borne by the manufacturer, as confirmed
through their Letter No. NIL dated September 28,
2016.

24. 2 Page 645 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GRID SOLUTIONS ENERJI ENDUSTRISI SUSPENDED for all SEC/National Grid SA ongoing
ANONIM SIRKETI and forthcoming projects based on VP,
TURKEY Engineering letter # 19-00366-30504401 dated
February 17, 2019.

New Remark
Previously ALSTOM GRID, GEBZE

CONDITION:
First Unit to be Type Tested in the presence of 03
SEC Engineers & 1 SEC approved Independent
Inspector

WARRANTY:
Six (6) years extended Warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply

Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].

24. 2 Page 646 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES Type / Model: Power Transformer Prequalified for power transformer up to 500
CORPORATION (HICO) MVA
SOUTH KOREA Rating: 380kV, 500MVA
Based on TS&SD fax#09-F01255/02-03032301
Plant -Republic of Changwon, Korea dated 25th. July 2009, it is pre-qualified for
Power Transformer up to 380kV, 500MVA as
Eric Rhie, 450, Gongdeok-Dong, confirming to SEC specification # 53-TMSS-02,
Mapo-Gu, Seoul , Korea rev.0
Tel:82-707-6180 with the following conditions:

Contact Person - Mr. Jason Kang; Sale • All type, design, special & routine tests as per
Manager & Mr. Young Kim; Sales SEC specifications/standards shall be carried out
Manager on the first batch to be supplied to SEC in
Contact Person Email ID - securing an order in the presence of three
[email protected] , (3) SEC engineers & one (1) approved
[email protected] independent inspection agency Inspector.
Website - • Seven (7) years warranty from the date of PAC
http://www.hyosung.co.kr/eng/index.js of the turnkey project in case of contract award
p?, www.hyosung.com or date of delivery in case of direct material
supply order.

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

24. 2 Page 647 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HITACHI LTD Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com

Contact Person - Mr. Anders L


katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

24. 2 Page 648 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS ENERGY (NURNBERG) Previously Name SIEMENS AG (NURNBERG)


GERMANY

Plant -NURNBERG

Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx

24. 2 Page 649 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Chongqing Transformer Hitachi Energy Ltd. 380KV Rated up to 502MVA PQ Letter
Co., Ltd. 7th Floor, Legend Tower, Based on S&SD letter # 23-01514-01-30504401
CHINA King Fahad Road, Olaya dated August 16, 2023, the manufacturer is
Dist. Riyadh. prequalified for 380KV Power Transformer rated
Plant -Chongqing. up to 502MVA as confirming to National Grid SA
Hatem, Alazzam specification # 53-TMSS-01, with the following
No.12 Shifeng Road, Yuzui Town, Transformers Market conditions:
Jiangbei District, Manager
+966112181777 ext TYPE TEST:
Chongqing 5725 or +966560955437 All type/ special/routine tests as per SEC/National
Grid SA Standards/Specifications shall be
Contact Person - Mr. Owen Wenhao Haja Shariff, PGTR conducted on the proposed Power Transformers
Ou ; Ms. JiangKe Huang Transformers, +966 11 in Chongqing’s Factory laboratory in the
Phone - +862381835118 2181777 or presence of three (03) SEC/National Grid SA
Email ID - +966561661385, engineers and one (01) SEC/National Grid SA
[email protected] haja.shariff1@hitachiene approved 3rd party Independent Inspection
Contact Person Email ID - rgy.com Agency (IIA) inspector during first project
[email protected] +966 11 218 1777 / +966 awarded. All cost of which shall be borne by the
; [email protected] 56 095 5437 manufacturer. This was confirmed in writing by
Website - www.hitachienergy.com hatem.alazzam@hitachie the manufacturer through their letter Ref. # Nil
nergy.com dated 09 March 2023.

WARRANTY
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered Power
Transformer in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # Nil dated 01 March
2024.

24. 2 Page 650 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens Energy Transformer Siemens Energy Limited Power Transformers up to 380kV and PQ Letter
(Guangzhou) Co., Ltd. Saudi Arabia 502MVA Based on S&SD letter #23-001180/01-30504401
CHINA Business Gate, Building dated June 21, 2023, the manufacturer is
C-1, Airport Road, prequalified for 380kV Power Transformer rated
Plant -Guangzhou, China Qurtubah District. P.O. above 100MVA, as confirming to National Grid SA
Box 39582, Riyadh specification # 53-TMSS-01, with the following
26, Jungong Road 510530 Guangzhou, 11489, Saudi Arabia conditions:
China +966566375966
kaisar.langoo@siemens- TYPE TEST:
Guangzhou energy.com All Type, Routine and Special tests as per
SEC/National Grid SA Specifications shall be
Contact Person - Mr. Sun Xiao Chang - conducted on the proposed Power Transformers
Jacky in the Manufacturer's Testing Laboratory in the
Phone - +86 (20) 62663792 presence of three (3) SEC/National Grid SA
Email ID - Engineers & one (1) SEC/National Grid SA
[email protected] approved Independent Inspection Agency (IIA)
Contact Person Email ID - Inspector. All costs of which shall be borne by
[email protected] the manufacturer. This was confirmed in writing
Website - www.siemens-energy.com by the manufacturer through their letter # Nil
dated December 22, 2021.

WARRANTY
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered 380kV
Power Transformer rated above 100MVA in
respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # Nil.

24. 2 Page 651 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TBEA Shenyang Transformer Group ESNAD ELBENA Power Transformers up to 380kV and PQ Letter:
Co., Ltd. CONSTRUCTION 502MVA Based on S&SD letter # 23-01799-01-30504401
CHINA COMPANY dated September 13, 2023, the manufacturer is
2601 King Abdullah prequalified for 380KV Power Transformer rated
Plant -China-Shenyang Road, Qudus up to 502MVA and Oil Immersed Reactor rated up
Neighborhood, Riyadh to 380kV as confirming to National Grid SA
No.32 Kaifa Blvd, Economic and 13214 - 8401. specification # 53-TMSS-01 and 58-TMSS-01,
Technological Development Zone, +966 594 000 333 with the following conditions:
Shenyang City, Liaoning Province, [email protected]
China m TYPE TEST:
All type/ special/routine tests as per SEC/National
Shenyang Grid SA Standards/Specifications shall be
conducted on the offered product in an
Contact Person - Jia Wei accredited test lab in the presence of three (03)
Phone - 0086 24 25698188 /+966 SEC/National Grid SA engineers and one (01)
558458177 SEC/National Grid SA approved 3rd party
Email ID - [email protected] Independent Inspection Agency (IIA) inspector
Contact Person Email ID - during first project awarded. All cost of which
[email protected] shall be borne by the manufacturer. This was
Website - http://www.tbea.com.cn confirmed in writing by the manufacturer through
their letter Ref. # Nil dated 31.08.2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the 380kV Transformer,
132kV Transformer and Shunt Reactor in respect
of the defects due to design, manufacturing,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
or from the date of first delivery (in case of
direct material supply order), as confirmed by the
manufacturer, through their Letter Ref. # Nil dated
31.08.2023.

Total = 21

POWER TRANSFORMERS
24. 3
DISSOLVED GAS ANALYZER Applicable Standards: 53-TMSS-03

24. 3 Page 652 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CAMLIN LIMITED Farad Trading Company TOTUS G9 PQ Letter


United Kingdom 7241, Al Amir Muhammed Based on S&SD letter # MPQ354016324-Class
Ibn Saud, Dammam I(b) - 2018 dated October 24, 2023, the
Plant -LISBURN, NORTHERN IRELAND 32241, Saudi Arabia manufacturer is prequalified for Dissolved Gas
+966 506806137 Analyzer as confirming to National Grid SA
31 Ferguson Drive, Lisburn, BT28 2EX, [email protected] specification # 53-TMSS-03 with following
Northern Ireland conditions:

LISBURN WARRANTY:
Ten (10) years extended warranty/guarantee to
Contact Person - Manivellan SEC/National Grid SA for Dissolved Gas Analyzer
Shanmugam in respect of the defects due to design,
Phone - +44 (0)28 9262 6989 manufacturing, installation and workmanship from
Email ID - [email protected] the date of Provisional Acceptance Certificate
Contact Person Email ID - (PAC) of the first turnkey project (in case of
manivellan.shanmugam@camlinenergy. contract award) or from the date of first delivery
com (in case of direct material supply order), as
Website - www.camlingroup.com confirmed by the manufacturer, through their
Letter Ref. # Nil dated May 02, 2019.

Total = 1

ELECTRICAL INSULATING OIL


25. 1
Uninhibited Insulating Mineral Oil Applicable Standards: 54-TMSS-01

25. 1 Page 653 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Ergon Refining Inc., Uninhibited Insulating Mineral Oils, Ergon Refining lnc., PQ Letter
United States HyVolt I USA has conducted Based on S&SD letter # 24-00216-30504401
the Type Tests in dated February 14, 2024, the manufacturer is
Plant -Vicksburg Bureau Veritas (BV) prequalified for Uninhibited Insulating Mineral Oils
Independent as confirming to National Grid SA specification #
2125, Haining Road, Laboratory from 54-TMSS-01, with the following conditions:
06-12-2023 to
Mississippi 17-01-2024 and in WARRANTY
Ergon Refinery Ten (10) years extended warranty/guarantee to
Contact Person - Karuna Sadasivam Laboratory from SEC/National Grid SA for the Uninhibited Insulating
Phone - +1601-630-8465 6-10 November Mineral Oils in respect of the defects due to
Email ID - 2023, in the design, manufacturing, installation and
[email protected] presence of SEC/NG workmanship from the date of Provisional
Website - Engineers. Acceptance Certificate (PAC) of the first turnkey
https://www.ergonspecialtyoils.com/ project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # Nill dated 14.04.2023

APAR INDUSTRIES LTD Type / Model: Uninhibited Naphthenic PQ Letter:


INDIA Mineral Insulating Oil type POWEROIL TS&SD letter # 11-00152-1-03032301 dated
TO 1020 (60U). 22/01/2011, it is pre-qualified for Uninhibited
Rable New Mumbai,India Naphthenic Mineral Insulating Oil type POWEROIL
TO 1020 (60U).
Website - http://www.apar.com
CONDITION: Nil

WARRANTY:
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.SSG/SEC/11, DT: 20TH April, 2007

NYNAS Chemtrade Delivery for KSA will be from Nynas -Belgium


SWEDEN Abdul Hakim Al-Okaish
Yanbu, Saudi Arabia
Website - 966 504624405
http://www.nynas.com/default.aspx?e [email protected]
pslanguage=EN m

25. 1 Page 654 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 3

ELECTRICAL INSULATING OIL


25. 2
Inhibited type mineral oil Applicable Standards: 54-TMSS-02

Ergon Refining Inc., Inhibited Insulating Mineral Oils, HyVolt Ergon Refining lnc., PQ Letter
United States III USA has conducted Based on S&SD letter # 24-00570-30504401
the Type Tests in dated February 19, 2024, the manufacturer is
Plant -Vicksburg Bureau Veritas (BV) prequalified for Inhibited Insulating Mineral Oils as
Independent confirming to National Grid SA specification #
2125, Haining Road, Laboratory from 54-TMSS-02, with the following conditions:
06-12-2023 to
Mississippi 17-01-2024 and in WARRANTY
Ergon Refinery Ten (10) years extended warranty/guarantee to
Contact Person - Karuna Sadasivam Laboratory from SEC/National Grid SA for the Inhibited Insulating
Phone - +1601-630-8465 6-10 November Mineral Oils in respect of the defects due to
Email ID - 2023, in the design, manufacturing, installation and
[email protected] presence of SEC/NG workmanship from the date of Provisional
Website - Engineers. Acceptance Certificate (PAC) of the first turnkey
https://www.ergonspecialtyoils.com/ project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # Nill dated 14.04.2023

Total = 1

RESISTOR
26. 1
NEUTRAL GROUNDING RESISTOR, 11 KV THROUGH 34.5 KV Applicable Standards: 57-TMSS-01

CRESSAL RESISTOR
United Kingdom

Website - http://www.cressall.com/

26. 1 Page 655 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

M.S.RESISTANCES WARRANTY:
FRANCE Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Website - installation & workmanship from the date of
http://www.msresistances.com Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

METAL DEPLOYE
FRANCE

Website -
http://www.metaldeploye.com

NATIONAL
INDIA

Plant -Ambattur, Chennai

33, Sidco Industrial Estate, Ambattur,


Chennai- 600 098, India

Phone - +91 44 2625 2262 / 2635 7368


Email ID -
[email protected], or
[email protected]
Website - http://www.national.com/

26. 1 Page 656 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Ergun Elektrik San.Tic.Ltd.Sti Al-Haitham for Industries PQ letter:


TURKEY & Economic Development Based on S&SD letter # 18-01736 dated May 8th,
+966-500024018 2018, Ergun Elektrik San.Tic.Ltd.Sti -Turkey is
Plant -Izmir, Turkey [email protected] pre-qualified for Neutral Grounding Resistors as
conforming to latest National Grid SA
Ergun Elektrik San.Tic.Ltd.Şti. specification # 57-TMSS-01
Sinem Ergun
Kazımdirik Mah. SanayiCad. No:66 WARRANTY:
35100 Bornova Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
İzmir installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Sinem Ergun first turnkey project in case of contract award or
Phone - +90 232 462 72 00 date of first delivery in case of direct material
Email ID - [email protected] supply order, as confirmed by the manufacturer
Contact Person Email ID - vide letter # Nil, dated March, 2013
[email protected]
Website - www.ergunelektrik.com

FURSE
United Kingdom

Website -
http://www.furse.com/home.htm

Total = 6

REACTOR
27. 1
OIL IMMERSED REACTORS, (33 KV TO 69 KV ) Applicable Standards: 58-TMSS-01

27. 1 Page 657 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HITACHI LTD Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.

Plant -T&D Systems Center, Amagasaki


City, Japan

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

27. 1 Page 658 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

HYOSUNG HEAVY INDUSTRIES Type / Model: Oil immersed Reactor PQ Letter:


CORPORATION (HICO) S&SD letter # 14-10289-02-30504401 dated 18
SOUTH KOREA Rating: up to 380kV January 2015, the manufacturer is prequalified
for Oil Immersed Reactor up to 380 KV
Plant -Republic of Changwon, Korea
CONDITION:
Eric Rhie, 450, Gongdeok-Dong, All type, special, routine tests for Oil Immersed
Mapo-Gu, Seoul , Korea Shunt Reactors per National Grid SA
Tel:82-707-6180 specifications and IEC standards & technical
requirements shall be conducted at
Contact Person - Mr. Jason Kang; Sale Manufacturer's Testing Laboratory in presence of
Manager & Mr. Young Kim; Sales three (3) SEC/National Grid SA engineers & one
Manager (1) company approved independent inspection
Contact Person Email ID - agency Inspector, at the sole expenses of
[email protected] , manufacturer on the first unit to be supplied to
[email protected] SEC/National Grid SA. This was confirmed
Website - through their letter # HS-SR-141027-01 dt: Oct
http://www.hyosung.co.kr/eng/index.js 27, 2014.
p?, www.hyosung.com
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer and
subsequently reduced yearly in case of future
project award through their letter#
HS-SRPQ-150107-01 dated January 7, 2015.

27. 1 Page 659 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BEST , (OSB FACTORY) Rating: Prequalified rated up to 132kV PQ letter:


TURKEY Based on S&SD letter # 17-03230-01-30504401
dated April 19, 2017, for Balikesir Elektromekanik
Plant -Turkey-Balikesir (Osb Factory) Sanayi Tesisleri (BEST) A.S., (OSB Plant) Turkey
is pre-qualified for Shunt Reactor rated up to
Contact Person - Mr. A. T. Haydar 132kV as conforming to latest National Grid SA
Sargin- General Manager ; Mr. Mehmet specification # 58-TMSS-01
ASLAN- Area Sales Manager
Contact Person Email ID -
[email protected] ; CONDITION:
[email protected] •All Type, Special & Routine tests as per latest
National Grid SA Specifications & IEC
requirements shall be carried out on the first unit
to be supplied to SEC/National Grid SA in the
manufacturer’s accredited Laboratory in the
presence of three (3) National Grid SA Engineers
& one (1) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
vide letter # BEST-100340-SEC-03, dated August
08, 2016.

WARRANTY:
•Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # BEST-100339-SEC-02, dated August
08, 2016.

GRID SOLUTIONS ENERJI ENDUSTRISI New Remark


ANONIM SIRKETI Previously ALSTOM GRID, GEBZE
TURKEY
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].

27. 1 Page 660 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CG POWER SYSTEMS BELGIUM NV Type / Model: Shunt Reactor On Hold


BELGIUM
Rating: up to 132kV
Plant -Mechelen Belgium PQ Letter:
S&SD letter# 14-08521-2-30504401 dated
December 10, 2014, pre-qualified for Shunt
Reactors rated up to 132kV.

CONDITION:
All Type, Special & Routine tests as per latest
National Grid SA Specifications & IEC
requirements [excluding Short circuit test ] shall
be carried out on the first unit to be supplied to
SEC/National Grid SA in the manufacturer
Laboratory in the presence of three (3) National
Grid SA Engineers & one (1) National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #Nil dated
November 10, 2012.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter #Nil dated 25 November 2014.

AREVA (ST. QUEN)


FRANCE

Website - http://www.areva.com/

27. 1 Page 661 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Green Transfo Energy Turkey Enerji RADYA International Type / Model: Shunt Reactor PQ Letter:
Endustrisi ve Ticaref Anonim sirketi EASTERN RING BRANCH S&SD Letter 12-03420-30504401 dated October
TURKEY ROAD Rating: 02, 2012, Schneider Electric from Turkey-Kocaeli
AR RAYYAN, RIYADH Upto 33kV only. pre-qualified for Shunt Reactors up to 33kV only.
Plant -Cayirova-Kocaeli-Turkey 11575
EXIT 14, RIYADH
Tosb Organize Sanayi Bölgesi (OSB) P.O. BOX 61891
Mah.2 Cad No:6-1 Çayırova Kocaeli KINGDOM OF SAUDI
ARABIA
Contact Person - Mr.Govindaraj TEL: 00966 11 4966667
SETHURAMAN, Mr.Ufuk Dogan
Contact Person Email ID - CONTACT PERSON: ASIF
govindaraj.sethuraman@green-transfo. NOORUOOIN SARANG
com ,[email protected] Phone: 0504799504;
Email:
[email protected]
om.sa

27. 1 Page 662 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd Type / Model: Shunt Reactor PQ Letter:


SOUTH KOREA TS&SD Letters # 10-02438-02-03032301 dated
August 31,2010 and 13-05782-1-30504401,
Plant -Ulsan December 11, 2013, pre-qualified for Shunt
Reactor as conforming to National Grid SA
1000, Bangeojinsunhwan-doro, specification # 58-TMSS-01, Rev.0 with the
Dong-gu, Ulsan, South Korea, following condition.

Ulsan CONDITION:

Contact Person - Mr. J.W(Jin) Lee WARRANTY:


Phone - +966-11-293-2026, Ten (10) years extended warranty/guarantee in
+82-10-4818-0822 respect of defects due to design, manufacture,
Contact Person Email ID - installation & workmanship from the date of
[email protected] Provisional Acceptance Certificate (PAC) of the
Website - first turnkey project in case of contract award or
http://www.hyundaielectric.com date of delivery in case of direct material supply
order and subsequently reduced yearly in case
of future project award. This was confirmed by
HHI –Korea through letter #S370 -1008-0182
dated 18/08/2010.

Previously Hyundai Heavy Industries Co. Ltd [The


name has been changed based on P&SFD letter
#17-04234/01-030504401 dated May 24, 2017].

Previously Hyundai Electric & Energy Systems


Co., Ltd., the name has been changed to HD
Hyundai Electric Co., Ltd

SIEMENS ENERGY (NURNBERG) Previously Name SIEMENS AG (NURNBERG)


GERMANY

Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx

27. 1 Page 663 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens Energy Austria GmbH


AUSTRIA

Weiz , Austria

Website - http://www.vatechetg.at/

PJSC ZAPOROZHTRANSFORMATOR Type / Model: Shunt Reactors PQ Letter:


(ZTR) S&SD letter# 13-07568-30504401 dated
Ukraine Rating: up to 132 kV December 31, 2013, pre-qualified for Shunt
Reactors rated up to 132 kV.
Plant -Zaporizhia , Ukraine
CONDITION:
All Type, Special & Routine tests as per latest
National Grid SA Specifications & IEC
requirements shall be carried out on the first/next
unit to be supplied to SEC/National Grid SA in an
Accredited Testing Laboratory in the presence of
three (3) National Grid SA Engineers & one (1)
National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter 1/115-3553 dated December
14, 2011.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #1/115-3552
dated December 14, 2011.

27. 1 Page 664 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TBEA Shenyang Transformer Group ESNAD ELBENA Oil immersed reactor rated up to 380kV PQ Letter:
Co., Ltd. CONSTRUCTION Based on S&SD letter # 23-01799-01-30504401
CHINA COMPANY dated September 13, 2023, the manufacturer is
2601 King Abdullah prequalified for 380KV Power Transformer rated
Plant -China-Shenyang Road, Qudus up to 502MVA and Oil Immersed Reactor rated up
Neighborhood, Riyadh to 380kV as confirming to National Grid SA
No.32 Kaifa Blvd, Economic and 13214 - 8401. specification # 53-TMSS-01 and 58-TMSS-01,
Technological Development Zone, +966 594 000 333 with the following conditions:
Shenyang City, Liaoning Province, [email protected]
China m TYPE TEST:
All type/ special/routine tests as per SEC/National
Shenyang Grid SA Standards/Specifications shall be
conducted on the offered product in an
Contact Person - Jia Wei accredited test lab in the presence of three (03)
Phone - 0086 24 25698188 /+966 SEC/National Grid SA engineers and one (01)
558458177 SEC/National Grid SA approved 3rd party
Email ID - [email protected] Independent Inspection Agency (IIA) inspector
Contact Person Email ID - during first project awarded. All cost of which
[email protected] shall be borne by the manufacturer. This was
Website - http://www.tbea.com.cn confirmed in writing by the manufacturer through
their letter Ref. # Nil dated 31.08.2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the 380kV Transformer,
132kV Transformer and Shunt Reactor in respect
of the defects due to design, manufacturing,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
or from the date of first delivery (in case of
direct material supply order), as confirmed by the
manufacturer, through their Letter Ref. # Nil dated
31.08.2023.

27. 1 Page 665 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Chongqing Transformer Hitachi Energy Ltd. Oil immersed reactor rated up to 380kV PQ Letter
Co., Ltd. 7th Floor, Legend Tower, Based on S&SD letter # 23-01514/03-30504401
CHINA King Fahad Road, Olaya dated August 27, 2023, the manufacturer is
Dist. Riyadh. prequalified for oil immersed reactor rated up to
Plant -Chongqing. +966 11 218 1777 / +966 380 kV as confirming to National Grid SA
56 095 5437 specification # 58-TMSS-01, with the following
No.12 Shifeng Road, Yuzui Town, hatem.alazzam@hitachie conditions:
Jiangbei District, nergy.com
TYPE TEST:
Chongqing All type/ special/routine tests as per SEC/National
Grid SA Standards/Specifications shall be
Contact Person - Mr. Owen Wenhao conducted on the proposed oil immersed reactor
Ou ; Ms. JiangKe Huang in Chongqing’s Factory laboratory in the
Phone - +862381835118 presence of three (03) SEC/National Grid SA
Email ID - engineers and one (01) SEC/National Grid SA
[email protected] approved 3rd party Independent Inspection
Contact Person Email ID - Agency (IIA) inspector during first project
[email protected] awarded. All cost of which shall be borne by the
; [email protected] manufacturer. This was confirmed in writing by
Website - www.hitachienergy.com the manufacturer through their letter Ref. # Nil
dated 09 March 2023.

WARRANTY
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered oil
immersed reactor in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # Nil dated 01 March
2024.

27. 1 Page 666 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Type / Model: Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia Rating: up to 69kV
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com

Contact Person - Mr. Anders L


katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

Total = 17

REACTOR
27. 2
OIL IMMERSED REACTORS, (110 KV TO 132 KV ) Applicable Standards: 58-TMSS-01

HITACHI LTD Rating - upto 380 kv Class Test Report No. - will Originally JAPAN AE POWER SYSTEM CORP and
JAPAN be submitted after subsequent change affected as per HITACHI
CN letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

27. 2 Page 667 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

HYOSUNG HEAVY INDUSTRIES Type / Model: Oil immersed Reactor PQ Letter:


CORPORATION (HICO) S&SD letter # 14-10289-02-30504401 dated 18
SOUTH KOREA Rating: up to 380kV January 2015, the manufacturer is prequalified
for Oil Immersed Reactor up to 380 KV.
Plant -Republic of Changwon, Korea
CONDITION:
Eric Rhie, 450, Gongdeok-Dong, All type, special, routine tests for Oil Immersed
Mapo-Gu, Seoul , Korea Shunt Reactors per National Grid SA
Tel:82-707-6180 specifications and IEC standards & technical
requirements shall be conducted at
Contact Person - Mr. Jason Kang; Sale Manufacturer's Testing Laboratory in presence of
Manager & Mr. Young Kim; Sales three (3) SEC/National Grid SA engineers & one
Manager (1) company approved independent inspection
Contact Person Email ID - agency Inspector, at the sole expenses of
[email protected] , manufacturer on the first unit to be supplied to
[email protected] SEC/National Grid SA. This was confirmed
Website - through their letter # HS-SR-141027-01 dated
http://www.hyosung.co.kr/eng/index.js October 27, 2014.
p?, www.hyosung.com
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by manufacturer &
subsequently reduced yearly in case of future
project award through their letter#
HS-SRPQ-150107-01 dated January 7, 2015.

27. 2 Page 668 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BEST , (OSB FACTORY) Rating: Prequalified rated up to 132kV PQ letter:


TURKEY Based on S&SD letter # 17-03230-01-30504401
dated April 19, 2017, for Balikesir Elektromekanik
Plant -Turkey-Balikesir (Osb Factory) Sanayi Tesisleri (BEST) A.S., (OSB Plant) Turkey
is pre-qualified for Shunt Reactor rated up to
Contact Person - Mr. A. T. Haydar 132kV as conforming to latest National Grid SA
Sargin- General Manager ; Mr. Mehmet specification # 58-TMSS-01
ASLAN- Area Sales Manager
Contact Person Email ID -
[email protected] ; CONDITION:
[email protected] •All Type, Special & Routine tests as per latest
National Grid SA Specifications & IEC
requirements shall be carried out on the first unit
to be supplied to SEC/National Grid SA in the
manufacturer’s accredited Laboratory in the
presence of three (3) National Grid SA Engineers
& one (1) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
vide letter # BEST-100340-SEC-03, dated August
08, 2016.

WARRANTY:
•Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # BEST-100339-SEC-02, dated August
08, 2016.

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

27. 2 Page 669 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GRID SOLUTIONS ENERJI ENDUSTRISI New Remark


ANONIM SIRKETI Previously ALSTOM GRID, GEBZE
TURKEY
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].

CG POWER SYSTEMS BELGIUM NV Type / Model: On Hold


BELGIUM
Rating: up to 132kV
Plant -Mechelen Belgium PQ Letter:
S&SD letter# 14-08521-2-30504401 dated
December 10, 2014, it is pre-qualified for Shunt
Reactors rated up to 132kV.

CONDITION:
All Type, Special & Routine tests as per latest
National Grid SA Standards & IEC requirements
[excluding Short circuit test ] shall be carried out
on the first unit to be supplied to SEC/National
Grid SA in the manufacturer Laboratory in the
presence of three (3) National Grid SA Engineers
& one (1) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil, dated November 10,
2012.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated 25
November 2014.

27. 2 Page 670 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

AREVA (ST. QUEN)


FRANCE

Website - http://www.areva.com/

MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 132kV
Plant -T&D Systems Center, Amagasaki
City, Japan

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

27. 2 Page 671 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd Type / Model: Shunt Reactor PQ Letter:


SOUTH KOREA TS&SD Letters # 10-02438-02-03032301 dated
Rating: 132kV August 31,2010 and 13-05782-1-30504401,
Plant -Ulsan December 11, 2013, pre-qualified for Shunt
Reactor.
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea, CONDITION:

Ulsan WARRANTY:
Ten (10) years extended warranty/guarantee in
Contact Person - Mr. J.W(Jin) Lee respect of defects due to design, manufacture,
Phone - +966-11-293-2026, installation & workmanship from the date of
+82-10-4818-0822 Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - first turnkey project in case of contract award or
[email protected] date of delivery in case of direct material supply
Website - order and subsequently reduced yearly in case
http://www.hyundaielectric.com of future project award. This was confirmed by
HHI –Korea through letter # S370-1008-0182
dated 18/08/2010.

Previously Hyundai Heavy Industries Co. Ltd [The


name has been changed based on P&SFD letter
#17-04234/01-030504401 dated May 24, 2017].

Previously Hyundai Electric & Energy Systems


Co., Ltd., the name has been changed to HD
Hyundai Electric Co., Ltd

SIEMENS ENERGY (NURNBERG) Previously Name SIEMENS AG (NURNBERG)


GERMANY

Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx

27. 2 Page 672 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PJSC ZAPOROZHTRANSFORMATOR Type / Model: Shunt Reactors PQ Letter:


(ZTR) S&SD letter# 13-07568-30504401 dated
Ukraine Rating: up to 132kV December 31, 2013, it is pre-qualified for Shunt
Reactors rated up to 132 kV.
Plant -Zaporizhia , Ukraine
CONDITION:
All Type, Special & Routine tests as per latest
National Grid SA Specifications/Standards & IEC
requirements shall be carried out on the first/next
unit to be supplied to SEC/National Grid SA in an
Accredited Testing Laboratory in the presence of
three (3) National Grid SA Engineers & one (1)
National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter 1/115-3553 dated December
14, 2011.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter # 1/115-3552
dated December 14, 2011.

Siemens Energy Austria GmbH


AUSTRIA

Weiz , Austria

Website - http://www.vatechetg.at/

27. 2 Page 673 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TBEA Shenyang Transformer Group ESNAD ELBENA Oil immersed reactor rated up to 380kV PQ Letter:
Co., Ltd. CONSTRUCTION Based on S&SD letter # 23-01799-01-30504401
CHINA COMPANY dated September 13, 2023, the manufacturer is
2601 King Abdullah prequalified for 380KV Power Transformer rated
Plant -China-Shenyang Road, Qudus up to 502MVA and Oil Immersed Reactor rated up
Neighborhood, Riyadh to 380kV as confirming to National Grid SA
No.32 Kaifa Blvd, Economic and 13214 - 8401. specification # 53-TMSS-01 and 58-TMSS-01,
Technological Development Zone, +966 594 000 333 with the following conditions:
Shenyang City, Liaoning Province, [email protected]
China m TYPE TEST:
All type/ special/routine tests as per SEC/National
Shenyang Grid SA Standards/Specifications shall be
conducted on the offered product in an
Contact Person - Jia Wei accredited test lab in the presence of three (03)
Phone - 0086 24 25698188 /+966 SEC/National Grid SA engineers and one (01)
558458177 SEC/National Grid SA approved 3rd party
Email ID - [email protected] Independent Inspection Agency (IIA) inspector
Contact Person Email ID - during first project awarded. All cost of which
[email protected] shall be borne by the manufacturer. This was
Website - http://www.tbea.com.cn confirmed in writing by the manufacturer through
their letter Ref. # Nil dated 31.08.2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the 380kV Transformer,
132kV Transformer and Shunt Reactor in respect
of the defects due to design, manufacturing,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
or from the date of first delivery (in case of
direct material supply order), as confirmed by the
manufacturer, through their Letter Ref. # Nil dated
31.08.2023.

27. 2 Page 674 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Chongqing Transformer Hitachi Energy Ltd. Oil immersed reactor rated up to 380kV PQ Letter
Co., Ltd. 7th Floor, Legend Tower, Based on S&SD letter # 23-01514/03-30504401
CHINA King Fahad Road, Olaya dated August 27, 2023, the manufacturer is
Dist. Riyadh. prequalified for oil immersed reactor rated up to
Plant -Chongqing. +966 11 218 1777 / +966 380 kV as confirming to National Grid SA
56 095 5437 specification # 58-TMSS-01, with the following
No.12 Shifeng Road, Yuzui Town, hatem.alazzam@hitachie conditions:
Jiangbei District, nergy.com
TYPE TEST:
Chongqing All type/ special/routine tests as per SEC/National
Grid SA Standards/Specifications shall be
Contact Person - Mr. Owen Wenhao conducted on the proposed oil immersed reactor
Ou ; Ms. JiangKe Huang in Chongqing’s Factory laboratory in the
Phone - +862381835118 presence of three (03) SEC/National Grid SA
Email ID - engineers and one (01) SEC/National Grid SA
[email protected] approved 3rd party Independent Inspection
Contact Person Email ID - Agency (IIA) inspector during first project
[email protected] awarded. All cost of which shall be borne by the
; [email protected] manufacturer. This was confirmed in writing by
Website - www.hitachienergy.com the manufacturer through their letter Ref. # Nil
dated 09 March 2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered oil
immersed reactor in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # Nil dated 01 March
2024.

27. 2 Page 675 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Type / Model: Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia Rating: up to 132kV
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com

Contact Person - Mr. Anders L


katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

Total = 17

REACTOR
27. 3
OIL IMMERSED REACTORS, (230 KV) Applicable Standards: 58-TMSS-01

HITACHI LTD Rating - upto 380 kv Class Test Report No. - will Originally JAPAN AE POWER SYSTEM CORP and
JAPAN be submitted after subsequent change affected as per HITACHI
CN letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

27. 3 Page 676 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

FUJI ELECTRIC CO. Originally JAPAN AE POWER SYSTEM CORP and


JAPAN subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

HYOSUNG HEAVY INDUSTRIES Type / Model: Oil immersed Reactor PQ Letter:


CORPORATION (HICO) S&SD letter # 14-10289-02-30504401 dated 18
SOUTH KOREA Rating: up to 380kV January 2015, the manufacturer is prequalified
for Oil Immersed Reactor up to 380 KV.
Plant -Republic of Changwon, Korea
CONDITION:
Eric Rhie, 450, Gongdeok-Dong, All type, special, routine tests for Oil Immersed
Mapo-Gu, Seoul , Korea Shunt Reactors per National Grid SA
Tel:82-707-6180 specifications and IEC standards & technical
requirements shall be conducted at
Contact Person - Mr. Jason Kang; Sale Manufacturer's Testing Laboratory in presence of
Manager & Mr. Young Kim; Sales three (3) SEC/National Grid SA engineers & one
Manager (1) company approved independent inspection
Contact Person Email ID - agency Inspector, at the sole expenses of
[email protected] , manufacturer on the first unit to be supplied to
[email protected] SEC/National Grid SA. This was confirmed
Website - through their letter # HS-SR-141027-01 dated
http://www.hyosung.co.kr/eng/index.js October 27, 2014.
p?, www.hyosung.com
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer and
subsequently reduced yearly in case of future
project award through their letter#
HS-SRPQ-150107-01 dated January 7, 2015.

27. 3 Page 677 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

GRID SOLUTIONS ENERJI ENDUSTRISI New Remark


ANONIM SIRKETI Previously ALSTOM GRID, GEBZE
TURKEY
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].

AREVA (ST. QUEN)


FRANCE

Website - http://www.areva.com/

MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 230kV
Plant -T&D Systems Center, Amagasaki
City, Japan

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

27. 3 Page 678 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd Type / Model: Shunt Reactor PQ Letter:


SOUTH KOREA TS&SD Letters # 10-02438-02-03032301 dated
Rating: 230kV August 31,2010 and 13-05782-1-30504401,
Plant -Ulsan December 11, 2013, pre-qualified for Shunt
Reactor.
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea, CONDITION:

Ulsan WARRANTY:
Ten (10) years extended warranty/guarantee in
Contact Person - Mr. J.W(Jin) Lee respect of defects due to design, manufacture,
Phone - +966-11-293-2026, installation & workmanship from the date of
+82-10-4818-0822 Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - first turnkey project in case of contract award or
[email protected] date of delivery in case of direct material supply
Website - order and subsequently reduced yearly in case
http://www.hyundaielectric.com of future project award. This was confirmed by
HHI –Korea through letter # S370-1008-0182
dated 18/08/2010.

Previously Hyundai Heavy Industries Co. Ltd [The


name has been changed based on P&SFD letter
#17-04234/01-030504401 dated May 24, 2017].

Previously Hyundai Electric & Energy Systems


Co., Ltd., the name has been changed to HD
Hyundai Electric Co., Ltd

SIEMENS ENERGY (NURNBERG) Previously Name SIEMENS AG (NURNBERG)


GERMANY

Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx

27. 3 Page 679 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens Energy Austria GmbH


AUSTRIA

Weiz , Austria

Website - http://www.vatechetg.at/

TBEA Shenyang Transformer Group ESNAD ELBENA Oil immersed reactor rated up to 380kV PQ Letter:
Co., Ltd. CONSTRUCTION Based on S&SD letter # 23-01799-01-30504401
CHINA COMPANY dated September 13, 2023, the manufacturer is
2601 King Abdullah prequalified for 380KV Power Transformer rated
Plant -China-Shenyang Road, Qudus up to 502MVA and Oil Immersed Reactor rated up
Neighborhood, Riyadh to 380kV as confirming to National Grid SA
No.32 Kaifa Blvd, Economic and 13214 - 8401. specification # 53-TMSS-01 and 58-TMSS-01,
Technological Development Zone, +966 594 000 333 with the following conditions:
Shenyang City, Liaoning Province, [email protected]
China m TYPE TEST:
All type/ special/routine tests as per SEC/National
Shenyang Grid SA Standards/Specifications shall be
conducted on the offered product in an
Contact Person - Jia Wei accredited test lab in the presence of three (03)
Phone - 0086 24 25698188 /+966 SEC/National Grid SA engineers and one (01)
558458177 SEC/National Grid SA approved 3rd party
Email ID - [email protected] Independent Inspection Agency (IIA) inspector
Contact Person Email ID - during first project awarded. All cost of which
[email protected] shall be borne by the manufacturer. This was
Website - http://www.tbea.com.cn confirmed in writing by the manufacturer through
their letter Ref. # Nil dated 31.08.2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the 380kV Transformer,
132kV Transformer and Shunt Reactor in respect
of the defects due to design, manufacturing,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
or from the date of first delivery (in case of
direct material supply order), as confirmed by the
manufacturer, through their Letter Ref. # Nil dated
31.08.2023.

27. 3 Page 680 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Chongqing Transformer Hitachi Energy Ltd. Oil immersed reactor rated up to 380kV PQ Letter
Co., Ltd. 7th Floor, Legend Tower, Based on S&SD letter # 23-01514/03-30504401
CHINA King Fahad Road, Olaya dated August 27, 2023, the manufacturer is
Dist. Riyadh. prequalified for oil immersed reactor rated up to
Plant -Chongqing. +966 11 218 1777 / +966 380 kV as confirming to National Grid SA
56 095 5437 specification # 58-TMSS-01, with the following
No.12 Shifeng Road, Yuzui Town, hatem.alazzam@hitachie conditions:
Jiangbei District, nergy.com
TYPE TEST:
Chongqing All type/ special/routine tests as per SEC/National
Grid SA Standards/Specifications shall be
Contact Person - Mr. Owen Wenhao conducted on the proposed oil immersed reactor
Ou ; Ms. JiangKe Huang in Chongqing’s Factory laboratory in the
Phone - +862381835118 presence of three (03) SEC/National Grid SA
Email ID - engineers and one (01) SEC/National Grid SA
[email protected] approved 3rd party Independent Inspection
Contact Person Email ID - Agency (IIA) inspector during first project
[email protected] awarded. All cost of which shall be borne by the
; [email protected] manufacturer. This was confirmed in writing by
Website - www.hitachienergy.com the manufacturer through their letter Ref. # Nil
dated 09 March 2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered oil
immersed reactor in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # Nil dated 01 March
2024.

27. 3 Page 681 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com

Contact Person - Mr. Anders L


katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

Total = 14

REACTOR
27. 4
OIL IMMERSED REACTORS, (380 KV ) Applicable Standards: 58-TMSS-01

HITACHI LTD Type / Model: Oil Immersed Shunt Originally JAPAN AE POWER SYSTEM CORP and
JAPAN Reactors subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan Rating: FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

Akihabara Daibiru Building, 18-13,


Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan

Contact Person - Mr. Masaharu Tsumori


Phone - +81-3-4564-4741
Email ID -
[email protected]
Website - http://www.hitachi.com

27. 4 Page 682 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TOSHIBA CORPORATION, T&D ORIGINALLY TMT&D CORP. & DISSOLVED


JAPAN DURING APRIL 2005.

Website -
http://www.toshiba.co.jp/index j3.htm

MITSUBISHI ELECTRIC CORPORATION Type / Model: Oil Immersed Shunt ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN Reactors DURING APRIL 2005.

Plant -T&D Systems Center, Amagasaki


City, Japan Rating: 380kV

Mitsubishi Electric Corporation, Tdsc,


Marketing Department, 8-1-1
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan

Contact Person - Mr. Yohei Okada


Phone - +81-6-6497-8288
Email ID -
[email protected].
jp
Website -
http://global.mitsubishielectric.com/

FUJI ELECTRIC CO. Type / Model: Oil Immersed Shunt Originally JAPAN AE POWER SYSTEM CORP and
JAPAN Reactors subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Rating: FUJI letter # AT-LTR-121115-1, dated 18-12-2012.

27. 4 Page 683 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES Type / Model: Oil Immersed Shunt Type, Routine PQ Letter:
CORPORATION (HICO) Reactors &Special tests shall S&SD letter # 14-10289-02-30504401 dated 18
SOUTH KOREA be conducted January 2015, the manufacturer is prequalified
Rating: 380kV for Oil Immersed Reactor up to 380 KV.
Plant -Republic of Changwon, Korea
CONDITION:
Eric Rhie, 450, Gongdeok-Dong, All type, special, routine tests for Oil Immersed
Mapo-Gu, Seoul , Korea Shunt Reactors per National Grid SA
Tel:82-707-6180 specifications and IEC standards & technical
requirements shall be conducted at
Contact Person - Mr. Jason Kang; Sale Manufacturer's Testing Laboratory in presence of
Manager & Mr. Young Kim; Sales three (3) SEC/National Grid SA engineers & one
Manager (1) company approved independent inspection
Contact Person Email ID - agency Inspector, at the sole expenses of
[email protected] , manufacturer on the first unit to be supplied to
[email protected] SEC/National Grid SA. This was confirmed
Website - through their letter # HS-SR-141027-01 dated
http://www.hyosung.co.kr/eng/index.js October 27, 2014.
p?, www.hyosung.com
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by manufacturer and
subsequently reduced yearly in case of future
project award through their letter#
HS-SRPQ-150107-01 dated January 7, 2015.

ABB ( T& D) Type / Model: Oil Immersed Shunt


United States Reactors

Plant -United States Rating:

Website - http://www.abb.us/

27. 4 Page 684 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GRID SOLUTIONS ENERJI ENDUSTRISI Type / Model: Oil Immersed Shunt Previously ALSTOM GRID, GEBZE
ANONIM SIRKETI Reactors
TURKEY PQ Letter:
Rating: 380 kV S&SD letter# 13-04034-2-30504401 dated
September 12, 2013, pre-qualified for 380 kV Oil
Immersed Shunt Reactors.

CONDITION:
All type/special, routine tests for 380 kV Oil
Immersed Shunt Reactors on one unit of each
rating supplied to SEC shall be conducted at
Manufacturer's Testing Laboratory in presence of
three (3) SEC/National Grid SA engineers & one
(1) SEC approved independent inspection agency
Inspector, all the related costs for witnessing the
tests will be borne by the manufacturer. This
was confirmed by Alstom Grid, Turkey through
their letter # Nil, dated July 22, 2013.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by Alstom Grid, Turkey
through their letter # Nil, dated July 22, 2013.

AREVA (ST. QUEN) Type / Model: Oil Immersed Shunt


FRANCE Reactors

Website - http://www.areva.com/ Rating:

27. 4 Page 685 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HD Hyundai Electric Co., Ltd Type / Model: Oil Immersed Shunt PQ Letter:
SOUTH KOREA Reactors TS&SD Letters # 10-02438-02-03032301 dated
August 31,2010 and 13-05782-1-30504401,
Plant -Ulsan Rating: 380kV December 11, 2013, pre-qualified for Shunt
Reactor.
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea, CONDITION:

Ulsan WARRANTY:
Ten (10) years extended warranty/guarantee in
Contact Person - Mr. J.W(Jin) Lee respect of defects due to design, manufacture,
Phone - +966-11-293-2026, installation & workmanship from the date of
+82-10-4818-0822 Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - first turnkey project in case of contract award or
[email protected] date of delivery in case of direct material supply
Website - order and subsequently reduced yearly in case
http://www.hyundaielectric.com of future project award. This was confirmed by
HHI –Korea through letter # S370-1008-0182
dated 18/08/2010.

Previously Hyundai Heavy Industries Co. Ltd [The


name has been changed based on P&SFD letter
#17-04234/01-030504401 dated May 24, 2017].

Previously Hyundai Electric & Energy Systems


Co., Ltd., the name has been changed to HD
Hyundai Electric Co., Ltd

SIEMENS ENERGY (NURNBERG) Previously Name SIEMENS AG (NURNBERG)


GERMANY

Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx

27. 4 Page 686 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Siemens Energy Austria GmbH


AUSTRIA

Weiz , Austria

Website - http://www.vatechetg.at/

TBEA Shenyang Transformer Group ESNAD ELBENA Oil immersed reactor rated up to 380kV PQ Letter:
Co., Ltd. CONSTRUCTION Based on S&SD letter # 23-01799-01-30504401
CHINA COMPANY dated September 13, 2023, the manufacturer is
2601 King Abdullah prequalified for 380KV Power Transformer rated
Plant -China-Shenyang Road, Qudus up to 502MVA and Oil Immersed Reactor rated up
Neighborhood, Riyadh to 380kV as confirming to National Grid SA
No.32 Kaifa Blvd, Economic and 13214 - 8401. specification # 53-TMSS-01 and 58-TMSS-01,
Technological Development Zone, +966 594 000 333 with the following conditions:
Shenyang City, Liaoning Province, [email protected]
China m TYPE TEST:
All type/ special/routine tests as per SEC/National
Shenyang Grid SA Standards/Specifications shall be
conducted on the offered product in an
Contact Person - Jia Wei accredited test lab in the presence of three (03)
Phone - 0086 24 25698188 /+966 SEC/National Grid SA engineers and one (01)
558458177 SEC/National Grid SA approved 3rd party
Email ID - [email protected] Independent Inspection Agency (IIA) inspector
Contact Person Email ID - during first project awarded. All cost of which
[email protected] shall be borne by the manufacturer. This was
Website - http://www.tbea.com.cn confirmed in writing by the manufacturer through
their letter Ref. # Nil dated 31.08.2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the 380kV Transformer,
132kV Transformer and Shunt Reactor in respect
of the defects due to design, manufacturing,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
or from the date of first delivery (in case of
direct material supply order), as confirmed by the
manufacturer, through their Letter Ref. # Nil dated
31.08.2023.

27. 4 Page 687 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Chongqing Transformer Hitachi Energy Ltd. Oil immersed reactor rated up to 380kV PQ Letter
Co., Ltd. 7th Floor, Legend Tower, Based on S&SD letter # 23-01514/03-30504401
CHINA King Fahad Road, Olaya dated August 27, 2023, the manufacturer is
Dist. Riyadh. prequalified for oil immersed reactor rated up to
Plant -Chongqing. +966 11 218 1777 / +966 380 kV as confirming to National Grid SA
56 095 5437 specification # 58-TMSS-01, with the following
No.12 Shifeng Road, Yuzui Town, hatem.alazzam@hitachie conditions:
Jiangbei District, nergy.com
TYPE TEST:
Chongqing All type/ special/routine tests as per SEC/National
Grid SA Standards/Specifications shall be
Contact Person - Mr. Owen Wenhao conducted on the proposed oil immersed reactor
Ou ; Ms. JiangKe Huang in Chongqing’s Factory laboratory in the
Phone - +862381835118 presence of three (03) SEC/National Grid SA
Email ID - engineers and one (01) SEC/National Grid SA
[email protected] approved 3rd party Independent Inspection
Contact Person Email ID - Agency (IIA) inspector during first project
[email protected] awarded. All cost of which shall be borne by the
; [email protected] manufacturer. This was confirmed in writing by
Website - www.hitachienergy.com the manufacturer through their letter Ref. # Nil
dated 09 March 2023.

WARRANTY:
Ten (10) years extended warranty/guarantee to
SEC/National Grid SA for the offered oil
immersed reactor in respect of the defects due to
design, manufacturing, installation and
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) or from the
date of first delivery (in case of direct material
supply order), as confirmed by the manufacturer,
through their Letter Ref. # Nil dated 01 March
2024.

27. 4 Page 688 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

BALIKESIR ELEKTROMEKANIK SANAYI PQ Letter


TESISLERI A.S. (BEST) Based on S&SD letter# MPQ675212927-Class I(a)
TURKEY - 2019 dated June 10, 2020, the manufacturer is
prequalified for OIL IMMERSED REACTORS, (380
Plant -BALIKESIR Turkey KV ) as confirming to National Grid SA
specification # 58-TMSS-01, with the following
OSB FACTORY - ORGANIZE SANAYI conditions:
BOLGESI 7. CADDE NO:1 7. CADDE
BALIKESIR Turkey WARRANTY
(10) years Extended Warranty shall be applicable
BALIKESIR for the OIL IMMERSED REACTORS, (380 KV ) to
be supplied to SEC/National Grid SA as confirmed
Contact Person - Mr. A. T. Haydar through Letter # 19-02-01-18072019 dated-
Email ID - [email protected] 18/07/2019
Contact Person Email ID -
[email protected] Type Test
All type, special & routine tests for 380 kV Oil
Immersed Shunt Reactors supplied to SEC shall
be conducted at BEST A.S accredited and
independent test laboratories in presence of
three (3) SEC/National Grid SA engineers & one
(1) SEC approved independent inspection agency
Inspector. All the related costs for witnessing the
tests shall be borne by the manufacturer. This
was confirmed by BEST, Turkey through their
letter # 20.04.06.29042020, dated April 29, 2020

27. 4 Page 689 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Sweden AB Hitachi Energy Type / Model: Oil Immersed Shunt Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Reactors Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +46107384456 Rating:
amit.x.nikhare@hitachien 380kV
Ludvika, Sweden ergy.com

Contact Person - Mr. Anders L


katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
[email protected]
om
Contact Person Email ID -
[email protected]
om
Website - www.hitachienergy.com

Total = 15

REACTOR
27. 5
AIR CORE SERIES REACTOR, 13.8KV THROUGH 380KV (230 KV AIR CORE Applicable Standards: 52-TMSS-02, 58-TMSS-02

NOKIAN – GRID SOLUTIONS OY LTD. Type / Model: Air core series reactor PQ Letter:
FINLAND S&SD letter # 14-03642-01-30504401 dated June
Rating; 145kV 11, 2014, NOKIAN – ALSTOM Grid oy Ltd.
Tampere , Finland Tampere-Finland is pre-qualified for Air Core
P.O.Box 4, Kaapelikatu 3 fl-33331 Series Reactors up to145 kV.
Vehmaistenkatu 5 fl-33730
WARRANTY:
Phone - +358 3 388311 Ten (10) years extended warranty/guarantee in
Email ID - [email protected] respect of defects due to design, manufacture,
Website - www.gegridsolutions.com installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter # Nil, dated 20th June 2012.

PREVIOUSLY NOKIAN - ALSTOM GRID Oy (LTD.)

27. 5 Page 690 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

POWER ECONOMY MIDDLE EAST CO. Type / Model: Air core Reactor. PQ Letter:
United Arab Emirates Based on TS&SD letter #07-F691-03032300
Rating: Limited to 34.5kV only dated May 21, 2007, it is pre-qualified for Air Core
Plant -Abu Dhabi , United Arab Emirates Reactors Limited to 34.5kV only

Website - WARRANTY:
http://www.powereconomy.net/ Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed through the manufacturer
letter # O-694-KSA-SEC, dated 20th Nov,2006.

TRENCH Type / Model: Air core series reactor PQ Letter:


AUSTRIA TS&SD letter 10-01317-1-03032301 dated May
10, 2010. TRENCH AUSTRIA GMBH is
Plant -Leonding, Linz, Austria pre-qualified for Air Core Series Reactors.

Austria Gmbh WARRANTY:


Seven (7) years Extended Warranty shall be
applicable for the Air Core Series Reactors to be
supplied to SEC by TRENCH AUSTRIA GMBH as
confirmed through their letter # NIL dated April 28,
2010.

TRENCH Type / Model: Air Core Series Reactors PQ Letter:


CANADA TS&SD letter 10-01317-1-03032301 dated May
10, 2010. TRENCH CANADA is pre-qualified for
Plant -Scarborough, Ontario, Canada Air Core Series Reactors.

WARRANTY:
Seven (7) years Extended Warranty shall be
applicable for the Air Core Series Reactors to be
supplied to SEC by TRENCH CANADA as
confirmed through their letter # NIL dated April 28,
2010.

Total = 4

27. 5 Page 691 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SPARE PARTS FOR RMU & EOS


28. 1
SPARE PARTS FOR RMU & EOS Applicable Standards:

CELLMEC
BAHRAIN

Website - http://www.cellmec.com/

Total = 1

SHEATH VOLTAGE LIMITERS (SVL)


29. 1
SHEATH VOLTAGE LIMITERS (SVL) Applicable Standards:

ABB
SWITZERLAND

Contact Person - Mr. Klaus Lohse


Phone - +41 58 588 33 50
Email ID - [email protected]
Website - http://www.abb.ch/

Insulect Australia PTE- Power Previously HAYCOLEC SWITCHGEAR PTY –


AUSTRALIA Transmission and Australia-NSW [The name has been changed to
Telecommunication AK POWER SOLUTONS PTY LTD- Australia-
Huntingwood, Nsw , Australia Equipment Co Huntingwood, NSW based on S&SD/P&SFD letter
8131 Modon 3 Jeddah # 13-07444-30504401 dated December 11, 2013
Industrial City Plot No 25: and based on AK POWER SOLUTONS PTY LTD-
P.O Box 8234 Jeddah Australia-NSW-Huntingwood Letter # NG251113
22772-2478 dated November 25, 2013]
Tel: +966 1260 95165:
Cell Ph: +966 595 33 23
74
[email protected] ,
[email protected]

Total = 2

LINE SUPPORT STRUCTURE


30. 1
WOOD POLES, ANSI CLASS HI–H3 Applicable Standards:

30. 1 Page 692 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ATLANTIC WOOD IND.


United States

Georgia , United States

Website -
http://www.atlanticwood.com/

CAHABA PRESSURE TREATED FOREST


PRODUCT (NORTH PACIFIC GROUP)
United States

Alabama , United States

COLFAX CREOSOTING CO
United States

Louisiana , United States

KOPPERS INDUSTRIES
United States

Pa , United States

Website - http://www.koppers.com/

STALLWORTH TIMBER
United States

Alabama , United States

STELLA JONES INC.


CANADA

New Westminster , Canada

Website -
http://www.stella-jones.com/welcome
eng.htm

30. 1 Page 693 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TAYLOR LUMBER (NORTH PACIFIC


GROUP)
United States

Oregon , United States

Website -
http://www.taylorlumberinc.com/

Total = 7

LINE SUPPORT STRUCTURE


30. 2
WOOD POLES, ANSI CLASS I – 4 Applicable Standards:

ATLANTIC WOOD IND.


United States

Georgia , United States

Website -
http://www.atlanticwood.com/

CAHABA PRESSURE TREATED FOREST


PRODUCT (NORTH PACIFIC GROUP)
United States

Alabama , United States

COLFAX CREOSOTING CO
United States

Louisiana , United States

KOPPERS INDUSTRIES
United States

Pa , United States

Website - http://www.koppers.com/

30. 2 Page 694 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

STALLWORTH TIMBER
United States

Alabama , United States

STELLA JONES INC.


CANADA

New Westminster , Canada

Website -
http://www.stella-jones.com/welcome
eng.htm

TAYLOR LUMBER (NORTH PACIFIC


GROUP)
United States

Oregon , United States

Website -
http://www.taylorlumberinc.com/

Total = 7

RACEWAYS METAL ENCLOSED BUS DUCT, 4.16 – 13.8 KV OR 34.5 KV


31. 1
RACEWAYS METAL ENCLOSED BUS DUCT, 4.16 – 13.8 KV OR 34.5 KV Applicable Standards:

UNIBUS
United States

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

31. 1 Page 695 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

WESCOSA
Saudi Arabia

Plant -Dammam , Saudi Arabia

First Industrial City of Dammam, P.O.


Box 2389, Dammam 31451, Saudi
Arabia

Contact Person - +966500594704


Phone - +966138100234 Ext 3267
Email ID - [email protected] ,
[email protected]
Website - http://www.wescosa.com/

Total = 3

SWITCHES
32. 1
LV AUTO-TRANSFER SWITCH Applicable Standards:

ALSTOM
FRANCE

Website -
http://www.alstom.com/home/

ASCO
United Arab Emirates

Website - http://www.asco.co.ae

WESTINGHOUSE
United States

Website -
http://www.westinghouse.com

Total = 3

SWITCHES
32. 2
PAD MOUNTED SF6/OIL SWITCH, 34.5 KV Applicable Standards:

32. 2 Page 696 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FRITZ DRIESHER KG
GERMANY

Website -
http://www.driescher.de/home/index.ht
m

Total = 1

SWITCHES
32. 3
CIRCUIT SWITCHER, 69 –230 KV Applicable Standards:

S&C
United States

Website - http://www.sandc.com/

SIEMENS
GERMANY

Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany

Phone - +49 (911) 433 8321


Website -
www.siemens.com/ingenuityforlife

S&C
CANADA

Total = 3

TRANSDUCERS
33. 1
FREQUENCY TRANSDUCERS Applicable Standards:

ALSTOM
United States

Website -
http://www.alstom.com/home

33. 1 Page 697 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ISKRA MIS Adnan Sabban Type/Model - Saprk Energy DZ9 ACCEPTANCE SUBJECTED TO SUCCESSFUL
SLOVENIA Est Office #6 1st Floor Al PRODUCT EVALUATION / ACCEPTANCE BY SEC
Hamad II Center Al Zahra CONCERNED END USER DEPARTMENT FOR EACH
Kranj , Slovenia District PURCHASE ORDER / PROJECT DURING
050-55-989-84 ,Phone - TENDER/BIDDING STAGE.
050-55-989-84
[email protected]

Total = 2

TRANSDUCERS
33. 2
TAP POSITION TRANSDUCERS Applicable Standards:

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Total = 1

TRANSDUCERS
33. 3
TRANSDUCERS Applicable Standards:

ENERDIS
FRANCE

Website -
http://www.chauvin-arnoux.com/

TILLQUIST
SWEDEN

Website - http://www.tillquist.com/

33. 3 Page 698 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TYCO ELECTRONICS LTD ( PQ Lettter


CROMPTON INSTRUMENTS) Based on TS&SD Letters
United Kingdom (08-F00975/01-03032301 dated June 04, 2008),
(10-F00230/01-03032301 dated February 03,
Website - 2010) & (11-F03017/01-03032301 dated October
http://www.tycoelectronics.com/ 16, 2011). Integra 1560 is prequalified for
Transducers as confirming to SEC Specification #
40-TMSS-02, Rev.0 with the following condition:

WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order. This was confirmed by TYCO Electronic,
UK through their letter # INT-SEC-06 dated
Jamuary 03, 2008 and its amendment dated
November 21, 2011

Secure Meters (Sweden) AB Previously CEWE Instrument AB Sweden, the


ITALY name has been changed to SECURE METERS
(Sweden) AB
Piazza Manifattura, 1
38068 Rovereto (TN)

Rovereto

Contact Person - Sandeep Jadhav


Phone - +971561718333/ +971 4
2045618
Email ID -
[email protected]
Contact Person Email ID -
[email protected]
Website - www.securemeters.com

33. 3 Page 699 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

LSIS , WARRANTY
SOUTH KOREA Seven (07) years extended warranty/guarantee
in respect of defects due to design, manufacture,
Ls Tower, 127, Ls-Ro, Dongan-Gu, installation & workmanship from the date of
Anyang-Si, Gyeonggi-Do, Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Contact Person - Mr. Je-woo, Lee date of delivery in case of direct material supply
Assistant Manager order.
Phone - +82-2-2034-4541
Email ID - [email protected]
Website - http://www.lsis.com

Total = 5

TRANSDUCERS
33. 4
WATTHOURS/VARHOURS TRANSDUCERS Applicable Standards:

ISKRA MIS Adnan Sabban Type/Model - Sparklight , ADM 16 ACCEPTANCE SUBJECTED TO SUCCESSFUL
SLOVENIA Est Office #6 1st Floor Al PRODUCT EVALUATION / ACCEPTANCE BY SEC
Hamad II Center Al Zahra CONCERNED END USER DEPARTMENT FOR EACH
Kranj , Slovenia District PURCHASE ORDER / PROJECT DURING
Phone - 050-55-989-84 TENDER/BIDDING STAGE.
Email -
[email protected]

MITSUBISHI ELECTRIC
JAPAN

Website -
http://global.mitsubishielectric.com/

SCIENTIFIC COLUMBUS
United States

Website -
http://www.scientificcolumbus.com/

Total = 3

TRANSDUCERS
33. 5
VOLTAGE TRANSDUCERS Applicable Standards:

33. 5 Page 700 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ISKRA MIS ACCEPTANCE SUBJECTED TO SUCCESSFUL


SLOVENIA PRODUCT EVALUATION / ACCEPTANCE BY SEC
CONCERNED END USER DEPARTMENT FOR EACH
Kranj , Slovenia PURCHASE ORDER / PROJECT DURING
TENDER/BIDDING STAGE.

ABB (ASEA INC.)


CANADA

Montreal , Canada

Website - http://www.abb.ca/

TRANSDATA
United States

Website -
http://www.transdatainc.com/index.ht
m

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Total = 4

TRANSDUCERS
33. 6
WATTS/VARS TRANSDUCERS Applicable Standards:

ISKRA MIS ACCEPTANCE SUBJECTED TO SUCCESSFUL


SLOVENIA PRODUCT EVALUATION / ACCEPTANCE BY SEC
CONCERNED END USER DEPARTMENT FOR EACH
Kranj , Slovenia PURCHASE ORDER / PROJECT DURING
TENDER/BIDDING STAGE.

33. 6 Page 701 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB (ASEA INC.)


CANADA

Montreal , Canada

Website - http://www.abb.ca/

TRANSDATA
United States

Website -
http://www.transdatainc.com/index.ht
m

AREVA
United Kingdom

Plant -United Kingdom

Website - http://www.areva.com/

Total = 4

SUBSTATION AUTOMATION SYSTEM


34. 1
SUBSTATION AUTOMATION SYSTEM Applicable Standards: TES-P-107.01

34. 1 Page 702 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GRID SOLUTION ARABIA LIMITED PQ Lettter


Saudi Arabia Based on S&SD letter# 14-00832-2-30504401
dated February 27, 2014, ALSTOM Grid AG
Plant -Alkhobar , Saudi Arabia France –Montpelier/ U.K –Stafford with
integration and testing facility in Al-Khobar, KSA
Saudi Arabia is pre-qualified for substations rated up to 380 kV
against specification # TES-P-107.01, Rev.00
with the following conditions:

CONDITION
Type test shall be conducted in independent
testing laboratory for the SAS System as per
National Grid SA Specifications/Standards,
IEC61850 Edition2, and latest amendments of IEC
in an accredited laboratory in presence of three
(03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer by
ALSTOM Grid AG –France, U.K through their
letter SAS/TSSD/2014/WR1201-1 dated January
12, 2014.

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

Bay Controller Unit (BCU) type MICOM C264 from


ALSTOM –U.K Stafford is with ordering code
AGC264MB116910012X-Y-Z-PRP.

All the protection IED’s shall be as per section 15


National Grid SA list of technically acceptable
manufacturer’s.

SAS network shall be provided with SAS

34. 1 Page 703 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

oriented Industrial type Ethernet Switches per


SEC/National Grid SA approved list.

SAS software – lastest version of DS Agile,

SAS OI Server is provided with Advantech IPC


(Taiwan), SCADA gateway and IEC/IEC GTW is
provided with Advantech IPC(Taiwan),
Workstation OI Viewer is provided with
Advantech IPC(Taiwan), EW is provided with
Advantech IPC(Taiwan).

Previously ALSTOM GRID INTEGRATION &


TESTING FACILITY, SAUDI ARABIA, the name has
been changed to GRID SOLUTION ARABIA
LIMITED - SAUDI ARABIA based on their letter #
Nil, dated October 06, 2019.

META Switchgear a branch of MEMF SAS Software: Latest version of PQ Letter


Electrical Industries Co Zenon SAS Software from Based on S&SD letter # MPQ997516935 dated
Saudi Arabia COPA-DATA November 22, 2023, the manufacturer is
SAS Hardware: Shall be from latest prequalified for Substation Automation System
Plant -Riyadh , Saudi Arabia (Branch Of version of List of Technically Integrator for Substation up to 132kV as
Memf Electrical Industries Co.) Acceptable Manufacturers (LOTAM) complying to National Grid SA specification
SAS Design: Approved SAS #TES-P-107.01, with the following conditions:
P.O. 6189, 2nd industrial city Al-Kharj Standardization Design from National
road Riyadh Saudi Arabia Grid SA SAS Committee. WARRANTY:
Ten (10) years extended warranty from the date
Riyadh of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
Contact Person - Mr. Fahad Alharkan of direct material supply order), as confirmed,
/MEMF, Nasser Alenezy / MEMF through their Letter No META/PQ/SAS/001/21
Phone - +966 11 4966667 Ext.119 dated 11 July, 2021 shall be applicable for the
Email ID - equipment/system to be supplied to SEC/National
[email protected], Grid SA
[email protected]
Contact Person Email ID -
[email protected]
Website - www.kfbgroup.com.sa

34. 1 Page 704 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.

Plant -2Nd Industrial Area,Riyadh,, Previous name was ABB Electrical Industries
Company Ltd, and change to ABB Contracting Co.
Po Box 325841 Riyadh,11371 KSA Ltd based on S&SD letter #20-01681-30504401
dated October 01, 2020
Riyadh

Contact Person - Mr. Ahmed Abubasha PQ Letter


Contact Person Email ID - Based on S&SD letter 18-00789-1-30504401
[email protected] dated February 26, 2018, ABB Electrical
Industries Company Ltd. - KSA, Riyadh is
pre-qualified for rated up to 380 SUBSTATION
AUTOMATION SYSTEM (SAS), as conforming to
National Grid SA specification # TES-P-107.01,
Rev.0, with the following conditions:

Warranty
•Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their letter # PGGA/SAS/0101, dated
February 4, 2018 shall be applicable for all 380
kV SUBSTATION AUTOMATION SYSTEM (SAS),
to be supplied to SEC/National Grid SA.

Type Test
•Type Tests shall be conducted on the SAS
System as per the new IEC 61850-10 (2012-12)
Edition 2 in an accredited laboratory in presence
of three (3) SEC/National Grid SA Engineers and
one (1) Company approved IIA Inspector at the
sole expense of ABB as confirmed through their
letter # PSN/SAS/0709/08/2013, dated July 9,
2013

Bay Controller Unit (BCU) shall be type


REC670*1.2-B30X00-P02-B1X-BE-KB-B-B6X0-D1
AD1D1D1-XXX-XE.

34. 1 Page 705 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

All the protection IED’s shall be as per section 15


National Grid SA list of technically acceptable
manufacturer’s.

SAS network shall be provided with SAS


oriented Industrial type Ethernet Switches per
SEC/National Grid SA approved list.

Station Computer, Gateway, EWS and OWS shall


be from Advantech Taiwan.

Software shall be lastest version of Micro


SCADA.

Old remarks:
PQ Lettter
Based on S&SD letter# 14-00953-1-30504401
dated February 27, 2014, ABB Automation Co.
Ltd., Riyadh is pre-qualified for integration and
testing of SAS systems for substations rated up
to 230kV against specification # TES-P-107.01,
Rev.00 with the following conditions:

CONDITION
Type test shall be conducted in independent
testing laboratory for the SAS System as per
National Grid SA Specifications/Standards,
IEC61850 Edition2, and latest amendments of IEC
in an accredited laboratory in presence of three
(03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer by
ABB-Riyadh through their letter #
PSN/SAS/0709/08/2013 dated July 09, 2013.

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of

34. 1 Page 706 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Provisional Acceptance Certificate (PAC) of the


first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

Bay Controller Unit (BCU) shall be type


REC670*1.2-B30X00-P02-B1X-BE-KB-B-B6X0-D1
AD1D1D1-XXX-XE.

All the protection IED’s shall be as per section 15


National Grid SA list of technically acceptable
manufacturer’s.

SAS network shall be provided with SAS


oriented Industrial type Ethernet Switches per
SEC/National Grid SA approved list.

Station Computer, Gateway, EWS and OWS shall


be from Advantech Taiwan.

Software shall be lastest version of Micro


SCADA.

34. 1 Page 707 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SCHNEIDER ELECTRIC- LATTE,S Based on the S & SD letter#


FRANCE 14-00571-1-30504401 dated April 20, 2014,
Schneider Electric, Lattes, France is prequalified
Riyadh , Saudi Arabia for Substation Automation System (SAS) for
substations up to 380 kV with Integration and
Testing of SAS (to be performed only by
Schneider Electric), at EPS factory –Riyadh K.S.A
subject to the following conditions:

Type test shall be conducted in independent


testing laboratory for the SAS System as per
National Grid SA Specifications/Standards, IEC
61850 Edition 2, and latest amendments of IEC in
an accredited laboratory in presence of three
(03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer.

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

Bay Controller Unit (BCU)


Type MiCOM C264 with ordering codes as
follows:

1- For all bays except for Transformers (HV


side):
MiCOM C264M11I69100126030000U1111N10 {96
DI + 30 DO, 4 CT (Ph) + 5 VT}

2- For Transformer Bays (HV side):


MiCOM C264M11I691001260300A0U1111N10 {96
DI + 30 DO, 4CT (Ph) + 5 VT + 8 AI}( 8 Analog
Current Inputs selectable 4-20 mA, 0-1 mA, 0-5

34. 1 Page 708 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

mA, 0-10 mA, 0-20 mA )

3- For Common BCU:


MiCOM C264L11I6910002D010000U1111N10 {
208 DI + 10 DO}

4- For ABTS/ ACCS:


Old:
MiCOM C264L11I691000250300A0U1111N10 {80
DI +
New:
C264L11I6A100026040000U1111N10
C264L11I6A1000260400A0U1111N10

30 DO + 8 AI}
( 8 Analog Current Inputs selectable 4-20 mA, 0-1
mA, 0-5 mA, 0-10 mA, 0-20 mA )

Protection IEDS: From Manufacturers listed in


section 15 of the data base of Approved
Manufacturers.

SAS Equipment:

Station Computers: Advantech (Taiwan).

EWS: Advantech (Taiwan).

OWS: Advantech (Taiwan).

Gateway: Advantech (Taiwan).

Software: Latest version of PACiS

Ruggedized Ethernet Switches: “SAS network


shall be provided with ruggedized SAS oriented
Industrial type Ethernet Switches per
SEC/National Grid SA approved list”

34. 1 Page 709 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SEL PQ Lettter
United States Based on the S & SD letter# 14-01257-30504401
dated 23 March 2014, Schweitzer Engineering
Laboratory (SEL) -U.S.A is prequalified for
Substation Automation System (SAS) with
Integration and Testing of SAS to be performed
only by (SEL), at SEL Al-Khobar, KSA for SAS
Panels as Integration and testing of SAS panels
with following condition:

CONDITION
Type Tests: The manufacturer has confirmed to
perform the required type tests in Independent
Testing laboratories- KEMA as per SEC/National
Grid SA requirements, IEC 61850 Edition 2
standards in the presence of three (3)
SEC/National Grid SA Engineers and one (1)
Independent Inspector through reference letter #
SEL/SAS/08/2013.

WARRANTY
The manufacturer has agreed to give guarantee/
warranty to SEC/National Grid SA for the
proposed Substation Automation System (SAS)
from SEL U.S.A with Integration & Testing facility
at SEL Al-Khobar, KSA for SAS Panels as
Integration and testing of SAS panels in respect
of the defects due to design, manufacturing,
installation and workmanship for a period of ten
(10) years , This was confirmed in writing by the
manufacturer through their letter ref:
LSELSA/17-34,
dated June 14, 2017.

3. Bay Controller Unit (BCU) type SEL 451 from


SEL –U.S.A is with ordering code
04515611XC2X4H64444X1.

4. All the protection IED’s shall be as per section


15 National Grid SA list of technically acceptable
manufacturer’s.

34. 1 Page 710 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

5. Station Computer (FESC) SEL-3355, Gateway


SEL -3355, EWS: SEL-3355, OWS: SEL-3355.

6. Software: Survalent Technology EMEA from


U.S.A - the software shall comprise of latest
version of Survalent packages (Scada Manager,
Scada Explorer, and Worldview Professional).

7. “SAS network shall be provided with SAS


oriented Industrial type Ethernet Switches per
SEC/National Grid SA approved list”.

34. 1 Page 711 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SIEMENS Siemens Ltd IC SG EA Type/Model - Substation Automation Bay Controller Unit Old comments:
GERMANY Pro System (FOR NEW TYPE):
Jeddah 21412 Baladiyah Rating - 380 kV 13.8 kV Type test Report PQ Lettter
Plant -NURNBERG Germany Street PO Box 4621 Mr. #G0M-1412-4383-S Based on the S&SD letter#
Ahmad Ainousah 0C000-V01 Dated: 14-03345-02-30504401 dated May 20, 2014,
Ic Sg Ea Mf Wernerwerkdamm 5 13629 Phone - Bay Controller Unit December,2014 SIEMENS -Germany is prequalified for Substation
Berlin Germany. +966-12-6618869 (Old Type) Automation System (SAS) with Integration and
Email - Type 6MD85 Laboratory:Eurofins Testing at SIEMENS–Jeddah K.S.A up to 380kV
Phone - +49(30)386-26688 ahmad.ainousah@sieme Ordering code: ProductService projects subject to the following conditions
Email ID - ns.com 6MD85-P1G33877 GmbH
[email protected] Built-in functions: & RTDS Test Report CONDITION
CONTROL & MIMIC # EM DG PTI PSC Type test shall be conducted in independent
SYNCH Check /pc200768 / VH testing laboratory for the SAS components as
Metering Dated per National Grid SA requirements latest revision
Interlocking December,016 of IEC 61850 (edition 2) on the approved
Supervision & Monitoring Functions: Laboratory: Independent Testing laboratory witnessing by
CT supervision Siemens Germany three (3) National Grid SA engineers and one (1)
74TC AG approved Independent Agency Inspector (IIA). All
74DC Supervision costs of witnessing the tests shall be borne by
74 Lockout Supervision the Siemens – Jeddah K.S.A as per their
60VT confirmation through letter # Nil dated April 21,
DFR/SOE 2014.
Hardware:
4 CT Measurements WARRANTY:
12 VT = 3 X 4 VT SETS ( Upper BB, Ten (10) years extended warranty/guarantee in
Lower BB, respect of defects due to design, manufacture,
line ) VT`s installation & workmanship from the date of PAC
115 BI of the first turnkey project (in case of contract
09 BO award) or from the date of first delivery in case
IEC61850 -PRP x 2 FO ports of direct material supply order as confirmed from
(New Type) SIEMENS -Germany & for Integration & Testing
Type 6MD85 facility at SIEMENS –Jeddah K.S.A the
Ordering code: Siemens-Germany & Siemens –Jeddah K.S.A
6MD85-P1G33886 through their letter # Nil dated November 12,
Built-in functions: 2012.
CONTROL & MIMIC
SYNCH Check Bay Controller Unit (BCU) : type 6MD6 from
Metering SIEMENS –Germany is with ordering code
Interlocking (6MD6631-4EB90-0AA4+L0S) shall be used.
Supervision & Monitoring Functions:
CT supervision Protection IEDS: From Manufacturers listed in
74TC section 15 of the data base of Approved

34. 1 Page 712 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

74DC Supervision Manufacturers.


74 Lockout Supervision
60VT Station Computers: Advantech (Taiwan).
DFR/SOE
Hardware: Gateway: Advantech (Taiwan).
4 CT Measurements
4 VT EWS: Advantech (Taiwan).

OWS: Advantech (Taiwan).

Software: Latest version of SICAM PAS/PAS


CC/SCC.

Ruggedized Ethernet Switches: “SAS network


shall be provided with ruggedized SAS oriented
Industrial type Ethernet Switches per National
Grid SA approved list”

Bay Controller Unit

(FOR NEW TYPE):


PQ Letter:
Based on S&SD letter # 17-00825-30504401
dated March 14, 2017, Siemens Berlin, Germany
is pre-qualified for (SIPROTEC 5) as conforming
to National Grid SA specification # 41-TMSS-0

WARRANTY:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
ofdirect material supply order), as confirmed,
through their letter # EA PRO/Pz, dated April 22,
014 shall be applicable for all (SIPROTEC 5
Relays) to be supplied to SEC/National Grid SA.

34. 1 Page 713 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SPRECHER AUTOMATION GMBH ALFANAR ELECTRICAL up to 380KV 1. For Bay Controller Based on the S & SD fax #
AUSTRIA SYSTEMS Saudi Arabia Unit (BCU) type 16-08451-02-30504401 dated 16/11/2016
Plant -3Rd Industrial 1. For Bay Controller Unit (BCU) type Sprecon –E-C-96 Sprecher Automation GmbH –Austria with
Plant -Franckstrabe 51,4018 Linz, Zell Area, Al Sprecon –E-C-96 from SPRECHER – from SPRECHER – Integration and FAT at Al-Fanar Electrical System
am See & Vienna in Austria Kharaj Road, Riyadh AUSTRIA: AUSTRIA: –Riyadh K.S.A for Substation Automation
Saudi Arabia Sprecon E-C-96 BCU with ABTS/ACSE ALFANAR System- SAS up to 380KV is prequalified against
Contact Person - Mr. Peter Wach –Area Po Box 301 , Riyadh & ACCS Control Functions ELECTRICAL TES-P-107.01, Rev.00, with the following
Sales Manager 11411 , North SYSTEMS conditions:
Contact Person Email ID - Righ Road Between Exit successfully
[email protected] 5&6 completed type tests Type Tests: The manufacturer has confirmed to
Riyadh , Saudi Arabia on sprecon E-C-96 perform the required type tests in SEC/National
Contact Person - Mr. BCU based Grid SA approved Independent Testing laboratory
Samer Y. Mokdad , ABTS/ACSE & as per SEC/National Grid SA requirements , IEC
Executive Manager. ACCS Control 61850 Edition 2 standards in the presence of
Email: Functions Ref. three (3) SEC/National Grid SA Engineers and one
samer.mokdad@alfanar. #20-2141, Rev. (1) Independent Inspector through reference
com dated 07.02.2020, in letter dated 24/10/2016 , ref#
ashraf.mohamed@alfan KEMA – Netherland AES-SAS-PQA-2016/008.
ar.com Laboratory
Phone - Guarantee/Warranty: The manufacturer (Both
+966-540339574 Sprecher & Al-Fanar) has agreed to give
guarantee/ warranty to SEC/National Grid SA for
the proposed Substation Automation System
(SAS) from SPRECHER Automation GmbH
-Austria with Integration and FAT at AL-FANAR
ELECTRICAL SYSTEM –Riyadh K.S.A in respect
of the defects due to design, manufacturing,
installation and workmanship for a period of ten
(10) years , This was confirmed in writing by the
manufacturer through their letter for SAS.

1. For Bay Controller Unit (BCU) type Sprecon –


E-C-96 from SPRECHER –AUSTRIA:

PQ Letter

Based on S&SD letter # MPQ1119379 dated


December 01, 2021, the manufacturer is
prequalified for ABTS/ACSE & ACCS CONTROL
FUNCTIONS as conforming to National Grid SA
specification # TES-P-107.01, with the following
conditions:

34. 1 Page 714 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

WARRANTY

Ten (10) years extended warranty from the date


of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter # AES-SEC-PQA-2017/003
dated July 09, 2017 shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

2. All the protection IED’s shall be as per section


15 of National Grid SA list of technically
acceptable manufacturers.

3. Server, Gateway, EWS: from ADVANTECH –


Taiwan.

4. HMI Software: Sprecon V460 Server Energy


Edition.

5. Gateway Software: Sprecon V460 Process


Gateway

6. EWS Software: Sprecon Engineering Center.

7. All Ethernet switches and router used in SAS


shall be per National Grid SA list of technically
acceptable manufacturer’s.

34. 1 Page 715 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

System House Factory for Electrical SAS Software: Latest version of PQ Letter
Panels (SEP)-Riyadh Zenon SAS Software from
Saudi Arabia COPA-DATA Based on S&SD letter # 19-03431-30504401
dated November 26, 2019, SYSTEM HOUSE
Plant -2nd Industrial City, Riyadh, SAS Hardware: Shall be from latest FACTORY, Riyadh – Saudi Arabia is prequalified
Kingdom of Saudi Arabia. version of List of Technically for Substation Automation System Integrator for
Acceptable Manufacturers (LOTAM) Substation up to 132kV as confirming to National
Plant A: Building No. 8557, Street No. Grid SA specification # TES-P-107.01, with the
5807, SAS Design: Approved SAS following conditions:
2nd Industrial City, Riyadh, Postal Code Standardization Design from National
14334-4906, Grid SA Committee WARRANTY
Kingdom of Saudi Arabia.
Ten (10) years extended warranty from the date
Plant B: Building No. 6687, Street No. 3, of PAC of the first turnkey project (in case of
Unit No. 45, contract award) or date of first delivery (in case
2nd Industrial City, Riyadh, Postal Code of direct material supply order), as confirmed,
14331-3599, through their Letter No. SAS/W-19-001-R1 dated
Kingdom of Saudi Arabia. August 28, 2019 shall be applicable for the
equipment to be supplied to SEC/National Grid SA.
Riyadh
New
Contact Person - Bader Alhuthayli PQ Letter
Phone - +966 11 498 0822
Email ID - [email protected] Based on S&SD letter #23-02087/01-30504401
Contact Person Email ID - dated October 15, 2023, the manufacturer is
[email protected] prequalified for Substation Automation System
Website - https://sep.com.sa Integrator for Substation up to 380kV as
complying to National Grid SA specification
#TES-P-107.01, with the following conditions:

WARRANTY

Ten (10) years extended warranty/guarantee to


SEC/National Grid SA for the offered
SUBSTATION AUTOMATION SYSTEM up to 380kV
in respect of the defects due to design,
manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as

34. 1 Page 716 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

confirmed by the manufacturer, through their


Letter Ref. #23-SAS-PQNG101, dated May 20,
2023.

COPA-DATA ZENON SAS Software as per IEC Type tests PQ Letter


AUSTRIA 61850 Edition 2 successfully
conducted at KEMA Based on S&SD letter # 19-02739-30504401
Plant -Austria CONDITION – Netherlands, test dated October 01, 2019, the manufacturer is
The software shall be the latest report number: prequalified for Substation Automation System
COPADATA - Karolingerstr. 7b n/a version. 19-2710 , and at Software (ZENON Version no. 08 per IEC 61850
Karolingerstrae 7B Salzburg Austria KERI – Korea, test Edition 2) as confirming to National Grid SA
report number: specification # TES-P-107.01, with the following
Salzburg 19TC201469. conditions:

Contact Person - Alexander WARRANTY


Punzenberger , Reinfried
Koesslbacher Ten (10) years extended warranty from the date
Phone - +43 662 43 10 02-250 of PAC of the first turnkey project (in case of
Email ID - [email protected] , contract award) or date of first delivery (in case
[email protected] of direct material supply order), as confirmed,
Contact Person Email ID - through their Letter No. Nill dated September 18,
[email protected] , 2018 shall be applicable for the equipment to be
[email protected] supplied to SEC/National Grid SA.
Website - www.copadata.com

- ISO 9001 Certification: ISO 9001:2015


Certificate is still pending. COPA-DATA as
confirmed through their letter # NIL dated
21/08/2019, shall submit to National Grid SA on
April 2020.

- COPA –DATA Saudi Arabia Office: We have


received the confirmation from COPA-DATA to
open office in Saudi Arabia through their letter #
NIL dated 21/08/2019 after getting the Final
approval.

34. 1 Page 717 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Switzerland Ltd. Hitachi Energy Mfr. Name change from ABB SWITZERLAND LTD.
SWITZERLAND Hitachi Energy Ltd. ( GLOBAL SAS CENTER) to Hitachi Energy
Riyadh, Saudi Arabia Switzerland Ltd.
Plant -switzerland Phone: +966 11 2181703
Mobile: +966 500414555 Old remarks:
Bruggerstrasse 72, 5400 Baden
PQ Lettter
Baden Based on S&SD letter# 14-00953-1-30504401
dated February 27, 2014, ABB Switzerland Ltd.(
Contact Person - Mr. Ahmed Abubasha, Global SAS Center), Baden, Switzerland is
Mr. Abdulmajeed Alothman, Mr. Michal pre-qualified for Engineering, integration and
Adamski , Mr. Mohammed Ilyas testing of SAS systems for substations up to 380
Phone - +41 58 588 33 50,+41 58 585 kV against specification # TES-P-107.01, Rev.00
77 44 with the following conditions:
Email ID -
communication.networks@hitachienerg CONDITION
y.com Type test shall be conducted in independent
Contact Person Email ID - testing laboratory for the SAS System as per
[email protected] National Grid SA Specifications/Standards,
om IEC61850 Edition2, and latest amendments of IEC
,[email protected] in an accredited laboratory in presence of three
Website - www.hitachienergy.com (03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer.

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.

Bay Controller Unit (BCU) shall be type


REC670*1.2-B30X00-P02-B1X-BE-KB-B-B6X0-D1
AD1D1D1-XXX-XE.

All the protection IED’s shall be as per section 15


National Grid SA list of technically acceptable
manufacturer’s.

34. 1 Page 718 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SAS network shall be provided with SAS


oriented Industrial Ethernet Switches per
SEC/National Grid SA approved list.

Station Computer, Gateway, EWS and OWS shall


be from Advantech Taiwan.

Software shall be lastest version of Micro


SCADA..

Innovative Systems Co. Ltd. SAS Software: PQ Letter


Saudi Arabia Latest version of Zenon SAS Software Based on S&SD Letter # MPQ889616935-Class
from COPA-DATA. I(b)-2020 dated March 14, 2022, Innovative
Plant -Riyadh KSA System Co. Ltd. - Riyadh, Saudi Arabia is
SAS Hardware: prequalified for Substation Automation System
Innovative Systems - Street No. 20 Shall be from latest version of List of Integrator for Substation up to 132kV as
Along Street 59 Al Kharj Industrial City Technically Acceptable Manufacturers conforming to National Grid SA specification #
Riyadh Saudi Arabia (LOTAM). TES-P-107.01, with the following conditions:

Riyadh SAS Design: Warranty:


Approved SAS Standardization Design Ten (10) years extended warranty from the date
Contact Person - Kamal Al Muhanna, from National Grid SA SAS Committee. of PAC of the first turnkey project (in case of
CEO Rameez Mulki Substation contract award) or date of first delivery (in case
Automation BU Manager of direct material supply order). as confirmed,
Phone - +966114608160/61 through their letter No. KM220920/01, dated
Email ID - [email protected] September 22, 2020, shall be applicable for the
[email protected] equipment to be supplied to SEC/National Grid SA.

Total = 11

MODULAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS


35. 1
MODULAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS Applicable Standards:

NEST OY/NAPS
FINLAND

Total = 1

INSULATING OIL FOR LOW PRESSURE OIL FILLED (LPOF) CABLES


36. 1
INSULATING OIL FOR LOW PRESSURE OIL FILLED (LPOF) CABLES Applicable Standards:

36. 1 Page 719 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ATOFINA CHEMICALS
United States

Website - http://www.atofina.com

DIELECTRIC SYSTEM INC.


United States

Website -
http://www.dielectrictechnologies.com/
index.html

INDOPOL
FRANCE

Lavera , France

Website - http://www.indopol.com/

SIEMENS
GERMANY

Plant -Berlin. Germany

Freyeslebenstr 1 91058 Erlangen

Contact Person - Mr. Yaser Salih


Phone - +49-9131725216
Email ID - [email protected]
Website - http://
http://www.siemens.de/Pages/EntryPa
ge Redirect.aspx

FURUKAWA ELECTRIC CO. LTD.


JAPAN

Website - http://
http://www.furukawa.co.jp/english/ind
ex.

Total = 5

36. 1 Page 720 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

DC POWER SYSTEMS
37. 1
DC POWER SYSTEMS Applicable Standards:

EXIDE CORP.
United States

Pa , United States

Website - http://www.exide.com/

HARMER & SIMMONS


United Kingdom

Essex , United Kingdom

Website -
http://www.harmerandsimmons.com/

LORAIN PRODUCTS INTERNATIONAL


SALES
United States

Loarin , United States

SAFT POWER SYSTEMS SAS Previously SAFT-NIFE


FRANCE

Website -
http://www.powersupplysystems.com/
index2.htm

Total = 4

POWER LINE CARRIER EQPT.


38. 1
POWER LINE CARRIER EQPT. Applicable Standards:

NERA
NORWAY

38. 1 Page 721 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB-Ludvika
SWEDEN

Plant -Sweden

Ludvika, Sweden

Contact Person - Mr. Magnus


Johansson
Phone - +46 240 783228
Email ID -
[email protected]
Website - http://www.abb.se/

GENERAL ELECTRIC ENERGY-CPQP


United States

New York , United States

Website - http://www.ge.com/

ABB INFOCOM LTD.


FRANCE

Turgi , France

Website - http://www.abb.fr/

AREVA
FRANCE

SIEMENS
GERMANY

Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany

Phone - +49 (911) 433 8321


Website -
www.siemens.com/ingenuityforlife

Total = 6

38. 1 Page 722 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CABLE ISOLATION EQUIPMENT


39. 1
CABLE ISOLATION EQUIPMENT Applicable Standards:

POSITRON INDUSTRIES
CANADA

Montreal,Canada

Total = 1

VF INTERFACE EQPT.
40. 1
VF INTERFACE EQPT. Applicable Standards:

ABB INFOCOM LTD.


SWITZERLAND

Turgi , Switzerland

Website - http://www.abb.ch/

TELLABS INC.
United States

Website - http://www.tellabs.com/

Total = 2

RADIO/PAGING EQUIPMENT (MOBILE FIXED)


41. 1
RADIO/PAGING EQUIPMENT (MOBILE FIXED) Applicable Standards:

ELECTRONIA
Saudi Arabia

Al-Khobar , Saudi Arabia

Website - http://www.electronia.com/

GE/ERICSON
United States

41. 1 Page 723 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

GLENAYRE
CANADA

Bc , Canada

Website - http://www.glenayre.com

KENWOOD
United States

California , United States

Website -
http://www.kenwoodusa.com/

MOTOROLA
United States

Schamburg Il , United States

Website -
http://www.motorola.com/us/products.j
sp

NEC
United States

Website - http://www.nec.com/

NOKIA
FINLAND

Website - http://www.nokia.com/

PHILIPS
United Kingdom

Cambridge , United Kingdom

Website -
http://www.philips.co.uk/index.page

Total = 8

41. 1 Page 724 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TEST EQUIPMENT
42. 1
TEST EQUIPMENT Applicable Standards:

ACTERNA
United States

Website - http://www.acterna.com/

ANDO ELECTRIC CO. LTD


JAPAN

Tokyo , Japan

Website - http://www.ando.nl/

HEWLETT PACKARD CO.


United States

Website - http://www.hp.com/

IFR
United States

ROHDE & SCHWARZ


GERMANY

Website -
http://www2.rohde-schwarz.com/

TREND
SPAIN

Website -
http://es.trendmicro.com/es/home/

WANDEL & GOLTERMAN GMBH CO.


GERMANY

42. 1 Page 725 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

PHILIPS
United Kingdom

Cambridge , United Kingdom

Website -
http://www.philips.co.uk/index.page

Total = 8

TEST EQUIPMENT
42. 2
TEST EQUIPMENT (FIBER OPTIC RELATED) Applicable Standards: 48-TMSS-14

ANRITSU CORPORATION
JAPAN

Tokyo , Japan

Website - http://www.anritsu.com/

Total = 1

TEST EQUIPMENT
42. 3
TEST EQUIPMENT (RADIO RELATED) Applicable Standards:

BIRD
United States

Solon , United States

Website -
http://www.bird-electronic.com/

MARCONI
United Kingdom

Website -
http://mecss.com.sa/contact.html

Total = 2

42. 3 Page 726 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TEST EQUIPMENT
42. 4
TEST EQUIPMENT (RADIO/PAGING RELATED) Applicable Standards:

NEC
United States

Website - http://www.nec.com/

Total = 1

TEST EQUIPMENT
42. 5
RADIO/PAGING EQUIPMENT (ACCESSORIES) Applicable Standards:

ALLEN
United States

Dallas Texas , United States

ANDREW
United States

Il , United States

Website - http://www.andrew.com/

ANTENNA SPECIALIST (AS)


United States

Dallas Texas , United States

CELWAVE
United States

Website - http://www.celwave.com/

DECIBEL
United States

Dallas Texas, United States

42. 5 Page 727 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FLEXWELL
United States

Noth Haven, Connecticut, United States

JAYBEAM
United Kingdom

Northampton , United Kingdom

Website -
http://www.jaybeamwireless.com/inde
x.php

RADIO SPARES (RS)


United Kingdom

Northants , United Kingdom

Website - http://uk.rs-online.com/web/

Total = 8

UHF RADIO
43. 1
UHF RADIO Applicable Standards:

ASCOM
United Kingdom

Website -
http://www.ascom.co.uk/uk-en

SIMOCO
United Kingdom

Website -
http://www.simoco.com/index.php

ALCATEL
FRANCE

Website - http://www.alcatel.fr/

43. 1 Page 728 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 3

HIGH DIGITAL SUBSCRIBER LINE (HDSL)


44. 1
HIGH DIGITAL SUBSCRIBER LINE (HDSL) Applicable Standards:

NOKIA
FINLAND

Website - http://www.nokia.com/

ABB-Ludvika
SWEDEN

Plant -Sweden

Ludvika, Sweden

Contact Person - Mr. Magnus


Johansson
Phone - +46 240 783228
Email ID -
[email protected]
Website - http://www.abb.se/

NORTEL
CANADA

Website - http://www.nortel.com/

Total = 3

FIRE PROTECTION SYSTEM


45. 1
CARBON DIOXIDE (CO2) SYSTEM (GAS CYLINDERS & ACCCESSORIES) Applicable Standards: TES-B-106.03

45. 1 Page 729 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JANUS FIRE SYSTEMS Mr. John Parker CO2 UL Listed The manufacturer is added based on
United States + 9733888644 Low pressure & High Pressure confirmation by Industrial Security Sector
john.parker@amerex-fire Systems /Industrial Security Performance Department
1102 Rupccih Drive .com Manager as per email message of
Millennium Park January,16,2017”.
Crown point ,IN 46307
“ Janus Fire Systems, USA, has agreed to give
Telephone :219.663.1600 Guarantee/ Warranty to SEC/ National Grid SA
Fax : 219.663.4562 vide letter # Nil, dated April 07, 2017, for the
proposed Fire Fighting System-High Pressure
Contact Person - Barry Cornel Carbon Dioxide (CO2) in respect of the defects
Email ID - due to design and manufacturing for a period of
[email protected] ten (10) years from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) or from date of delivery
for the direct material supply order. The
guarantee/ warrant shall be applicable for the
first project and shall subsequently be reduced
yearly in case of future project award

NAFFCO NAFFCO UL listed Co2 extinguisheres ,model UL listed The manufacturer is added based on
United Arab Emirates PO BOX 67716 RIYADH 451,456,466, C -50-SE ,and C-100-SE. LPCB approved UL confirmation by Industrial Security Sector
11517 UL listed Dry Chemical Extinguishers listed Fire /Industrial Security Performance Department
NAFFCO, P.O Box :17014, Dubai, TEL : 0112824444 Wheeled type. Extinguishers ,and Manager as per email message of
United Arab Emirates. '[email protected] LPCB Mobile Fire Extingishres. LPCB/BSI approved January,16,2017”, and April 24, 2017
m'; Fire Extinguishers
Tel :- # 97148066666 '[email protected]'
Fax: # 971 48816229

Dubai

KIDDE LOCAL AGENT ENERGY HOUSE


United States

Website - http://www.kiddeus.com/

CARDOX LOCAL AGENT HEBA


United States

Website -
http://www.atd-cardox.com/atd-cardo
x-vertretungen.htm

45. 1 Page 730 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CHEMETRON LOCAL AGENT HEBA


United States

Website -
http://www.chemetron.com/utcfs/Temp
lates/Pages/Template-46/1,8060,pageId
=1192&siteId=374,00.html

FIKE
United States

Website - http://www.fike.com/

HYGOOD
United States

Website -
http://www.hygood.co.uk/default.asp

Total = 7

FIRE PROTECTION SYSTEM


45. 2
DELUGE VALVE, SPRAY NOZZLE, ALARM VALVE AND SPRINKLERS Applicable Standards: TES-B-106.04

GRINNEL
United States

Website - http://www.grinnell.com/

RELIABLE LOCAL AGENT AL-BILAD


United States

Website -
http://www.reliablesprinkler.com/

SPRAYSAFE
United States

Website -
http://www.centralspraysafe.com/cgi-
bin/webscripts/nph-home.pl

45. 2 Page 731 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

VIKING LOCAL AGENT AL-BILAD


United States

Website -
http://www.vikingrange.com/consumer
/index.jsp

WATTS
United States

Website - http://www.watts.com/

Total = 5

FIRE PROTECTION SYSTEM


45. 3
FM 200 SYSTEM-GAS CYLINDERS & ACCCESSORIES Applicable Standards: TES-B-106.05 (HFC-227 ea Clean Agent
Extengushing System)
JANUS FIRE SYSTEMS Mr. John Parker, FM200 System: UL Listed The manufacturer is added based on
United States Ph: + 9733888644 Sv, Mv and Lv Series. confirmation by Industrial Security Sector
john.parker@amerex-fire /Industrial Security Performance Department
1102 Rupccih Drive .com Manager as per email message of
Millennium Park January,16,2017”.
Crown point ,IN 46307 “Janus Fire Systems, USA, has agreed to give
Guarantee/ Warranty to SEC/National Grid SA
Telephone :219.663.1600 vide letter # Nil, dated April 07, 2017, for the
Fax : 219.663.4562 proposed Fire Fighting Systems -FM- 200
(HFC-227ea Heptalour-propane CF3CHFCF3) in
Contact Person - Barry Cornel respect of the defects due to design and
Email ID - manufacturing for a period of ten (10) years from
[email protected] the date of the Provisional Acceptance Certificate
(PAC) of the project (in case of contract award)
or from date of delivery for the direct material
supply order. The guara-tee/warrant shall be
applicable for the first project and shall
subsequ-ntly be reduced yearly in case of future
project award.

45. 3 Page 732 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Viking GmbH & Co. KG Advanced Elements for FM200 System: UL/FM/VdS The manufacturer is added based on
GERMANY Fire Protection Systems Model VSN200 @ 25, 42& 50 bars UL/FM/VdS confirmation by Industrial Security Sector
Tel: 0114722799 /Industrial Security Performance Department
INDUSTRIESTRASSE 10/12 Manager as per email message of
23480 BAD OLDESLOE, GERMANY January,16,2017

Telephone: +49 4531 / 803 -0


Fax: +49 4531 / 803 -137
Mobile: +436648366656

Contact Person - Peter Eisenberger


Email ID -
[email protected]

FIRETRACE Guarantee Business FM200 System: UL & ULC listed The manufacturer is added based on
United States Contracting Est Models,01-001372,01-001407, confirmation by Industrial Security Sector
KSA – P.O Box 26018 01-001487,01001587,01-001712,01-00 /Industrial Security Performance Department
USA L L C EX15893 Riyadh 1897,01-002537 all @360 psig (25 bar) Manager as per email message of
SUITE 2 0114919669 January,16,2017”.

8435 N 90TH ST
SCOTTSDALE, AZ 85258 USA
Middle East, North Africa & Caspian

Contact Person - Jim Dickinson -


Regional Business Manager
Phone - +971567599490
Email ID - [email protected]

SIEX Engineering Field Est. 1) SIEX –HC 227 (25 & 24 bar). UL Listed FM The manufacturer is added based on
SPAIN Phone : 02-6579028 2) SIEX –HC227 S- Flow (32.34.50.& approved. confirmation by Industrial Security Sector
Fax : 026579028 55 bar) /Industrial Security Performance Department
2001 SL Agil Alattas Manager as per email message of
POL INDUSTRIAL VILLAONQUEJAR [email protected] January,16,2017

C/MERINDAD DE MONTIJA NO 6
09001 BURGOS,SPAIN

45. 3 Page 733 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Fike Corporation NAFFCO Fike UL /FM approved FM 200 UL Listed FM The manufacturer is added based on
United Arab Emirates PO BOX 67716 RIYADH Using Fike impulse Valve with burst approved confirmation by Industrial Security
11517 disc Sec-or/Industrial Security Performance
Plant -Dubai Gulf Star Security & Department Manager per email mess-age of
Safety Jan-uary,16,2017”, and April 24, 2017.
Sheikh Zayed Road P.O Box 125917 Head office ,2nd floor ,Al
kaaf Al Akhdr Bldb,
Steen street , Jeddah
Al-Sarh Al-Methali
Trading
6th street ,off 95th
street. 2nd industrial City
Dammam
TEL : 0112824444

SIEMENS BUILDING TECHNOLOGIES – Siemens Ltd. Sinorix 227 (360 PSI) Fire Extinguishing UL Listed The manufacturer is added based on
FIRE SAFETY Business Gate, P.O. Box System. confirmation by Industrial Security Sector
United States 9510, 11423 Riyadh, •The gas is identified as:UL scope of fil /Industrial Security Performance Department
Saudi Arabia EX6288, SHANGHAI Waysmos Fine Manager as per email message of
SIEMENS INDUSTRY INC EX4724 Chemical Co Ltd (DBA Waysmos USA, January,16,2017”.
8 Fernwood Rd Tel +966 (11) 277 8208, Product tradename MH227),388 Liangle
Fax +966 (11) 277 8497, Rd, Laogang Town Pudong New
Florham Park, NJ 07932-1906 USA Mobile +966 (54) 335 District 201322 Shanghai, CHINA
0691, +966 (54) 346
3238
ashfaq.abdul-jabbar@si
emens.com

DUPONT
United States

GREAT LAKES
United States

Total = 8

FIRE PROTECTION SYSTEM


45. 4
FM 200 SYSTEM -EQUIPMENT- Applicable Standards: TES-B-106.05 (HFC-227 ea Clean Agent
Extengushing System)

45. 4 Page 734 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FENWAL
United States

Website - LOCAL AGENT ENERGY HOUSE


http://www.fenwalcontrols.com/utcfs/
Templates/Pages/Template-46/1,8060,p
ageId=1187&siteId=375,00.html

FIGGIE
United States

FIREATER
United States

KIDDE
United States

Website - http://www.kiddeus.com/

45. 4 Page 735 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

MINIMAX PQ Lettter
GERMANY Based on S&SD Letter 12-02704-02-30504001
dated February 19, 2012. It is pre-qualified for
Bad Oldesloe , Germany Fire Protective Signaling Panel as conforming to
SEC Specification # 90-TMSS-01 Rev.0

CONDITION
All Type, Routine and Special testes shall be
carried out on the first batch of Fire Protective
Signaling Panel in an Independent Testing
Laboratory in the presence of three (3) SEC
Engineers & one (1) SEC approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil dated January 11, 2011.

WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2011.

SIEMENS BUILDING TECHNOLOGIES PQ Lettter


United States Based on TS&SD Letter # 10-2425/02-03032301
dated 31/08/2010, it is pre-qualified for HFC227ea
Buffalo Grove , United States system (FM 200) as confirming to SEC
specification # TES-B-106.05, Rev.0

CHEMETRON LOCAL AGENT HEBA


United States

Website -
http://www.chemetron.com/utcfs/Temp
lates/Pages/Template-46/1,8060,pageId
=1192&siteId=374,00.html

45. 4 Page 736 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FIKE
United States

Website - http://www.fike.com/

HYGOOD
United States

Website -
http://www.hygood.co.uk/default.asp

ANSUL LOCAL AGENT AL-BILAD


United States

Website - https://
http://www.ansul.com/en/home.asp

Total = 10

FIRE PROTECTION SYSTEM


45. 6
Novec1230 System Applicable Standards: TES-B-106.06

SFFECO 3M Novec 1230 Fire protection UL Listed FM The manufacturer is added based on
Saudi Arabia Extinguishing system units having approved. confirmation by Industrial Security Sector
nominal ging capacitiec of Multiple Listing with /Industrial Security Performance Department
2ND INDUSTRIAL AREA 38,65,,130,2277,and 895 lb @ 25 bar. SEVO Manager as per email message of
AL-KHARJ RD Design & installation per Sevo VDS January,16,2017”.
PO BOX 58469 software Novec –Calculationprogram.
RIYADH, 11515 SAUDI ARABIA

Contact Person - Ibrahim Tumar


Phone - Te :0112650070
Email ID - [email protected]
Website - http://www.sffeco.com/

45. 6 Page 737 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JANUS FIRE SYSTEMS Mr. John Parker Novec1230 System: UL Listed “The manufacturer is added based on
United States Ph: + 9733888644 Sv, Mv and Lv Series confirmation by Industrial Security Sector
E Mail: /Industrial Security Performance Department
1102 Rupccih Drive john.parker@amerex-fire Manager as per email message of
Millennium Park .com January,16,2017”.
Crown point ,IN 46307 Janus Fire Systems, USA, has agreed to give
Guarantee/Warranty to SEC/National Grid SA vide
Telephone :219.663.1600 letter # Nil, dated April 07, 2017, for the proposed
Fax : 219.663.4562 Fire Fighting Systems-Novec 1230 Fluid
(F-K-1-12 Dodecafluoru-2-methylpentan-3-one
Contact Person - Barry Cornel CF2CF2C(O)CF(CF3)2) in respect of the defects
Email ID - due to design and manufacturing for a period of
[email protected] ten (10) years from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) or from date of delivery
for the direct material supply order. The
guarantee/warrant shall be applicable for the first
project and shall subsequently be reduced yearly
in case of future project award.

Viking GmbH & Co. KG Advanced Elements for Novec1230 System: UL/FM/VdS The manufacturer is added based on
GERMANY Fire Protection Systems Model VSN1230 @25, 42 &50 bars. UL/FM/VdS confirmation by Industrial Security Sector
Tel: 0114722799 /Industrial Security Performance Department
INDUSTRIESTRASSE 10/12 Manager as per email message of
23480 BAD OLDESLOE, GERMANY January,16,2017”.

Telephone: +49 4531 / 803 -0


Fax: +49 4531 / 803 -137
Mobile: +436648366656

Contact Person - Peter Eisenberger


Email ID -
[email protected]

45. 6 Page 738 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FIRETRACE Guarantee Business Novec1230 System: UL & ULC listed The manufacturer is added based on
United States Contracting Est Models : 01-001352, confirmation by Industrial Security Sector
KSA – 01-001366,01-001399, /Industrial Security Performance Department
USA L L C EX15893 P.O Box 26018 01-001440,01-001490, Manager as per email message of
SUITE 2 Riyadh 01-001564,01-001705,01- January,16,2017”.
0114919669 0011827 all @34 bar
8435 N 90TH ST
SCOTTSDALE, AZ 85258 USA
Middle East, North Africa & Caspian

Contact Person - Jim Dickinson -


Regional Business Manager
Phone - +971567599490
Email ID - [email protected]

MACRON SAFETY SYSTEMS LTD Abdulaziz Abdel Rahman 3M™ Novec™ 1230 Fire Protection PQ Letter
United Kingdom Jameel Square Fluid (FK-5-1-12) Clean Agent Based on S&SD letter # MPQ884819746 dated
Prince Mohammed Bin Extinguishing System. (HYGOOD & September 27, 2022, the manufacturer is
Plant -United Kingdom Abdulaziz St, Al SAPPHIRE) prequalified for Novec1230 System as confirming
Andalus, Jeddah 23326, to National Grid SA specification #TES-B-106.06,
Macron Safety System - Burlingham Saudi Aarbia with the following conditions:
House Hewett Road. Great Yarmouth +966 568888013
United Kingdom [email protected]
WARRANTY
Great Yarmouth Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
Contact Person - ROB WADE contract award) or date of first delivery (in case
Phone - +44 (0) 1493 417611 of direct material supply order), as confirmed,
Email ID - [email protected] through their Letter #Nil dated October 28, 2020,
Contact Person Email ID - shall be applicable for the equipment to be
[email protected] supplied to SEC/National Grid SA.
Website -
http://www.johnsoncontrols.com/

45. 6 Page 739 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KIDDE-FENWAL, INC. NOVEC™ 1230 Fire Protection Fluid PQ Letter


United States (FK-5-1-12) Clean Agent Extinguishing
System. D Based on S&SD letter #MPQ997619146-Class I(a)
Plant -Ashland -2021 dated April 05, 2023, the manufacturer is
prequalified for Novec1230 System as confirming
400 Main Street-Ashland, to National Grid SA specification # TES-B-106.06,
Massachusetts, USA with the following conditions:

Contact Person - Ismail AbouZaher


Phone - +1(508) 881-2000 WARRANTY
Email ID - [email protected] Ten (10) years extended warranty/guarantee to
Contact Person Email ID - SEC/National Grid SA for the offered Novec1230
[email protected] System in respect of the defects due to design,
Website - www.kidde-fenwal.com manufacturing, installation and workmanship from
the date of Provisional Acceptance Certificate
(PAC) of the first turnkey project (in case of
contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed by the manufacturer, through their
Letter Ref. # Nil dated July 07, 2023.

Total = 6

SAFETY AND SECURITY EQUIPMENT


46. 1
FIRE DETECTION AND ALARM SYSTEM (EQUIPMENT & ACCESSORIES) Applicable Standards: 90-TMSS-01,TES-B-106.01

SIMPLEX LOCAL AGENT –NAFISCO


United States

Website -
http://www.simplexgrinnell.com/

THORN
United Kingdom

Website -
http://www.thornlighting.co.uk/gb/en/in
dex.htm

AUTOCALL (GRINNEL)
United States

46. 1 Page 740 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

EDWARDS LOCAL AGENT AL-BILAD


CANADA

MIRETONE
United States

NOTIFIRE LOCAL AGENT -NAFISCO


United States

SIEMENS BUILDING TECHNOLOGIES – Originaly was PYROTRONICS from USA.


FIRE SAFETY Local Agents are: Siemens Building Technologies
United States (SBT) & SASEEQ

SIEMENS INDUSTRY INC EX4724


8 Fernwood Rd

Florham Park, NJ 07932-1906 USA

SHIELD FIRE SAFETY & SECURITY LTD NAFFCO Extinguishing Control panel mpdel A-Xt. UL Listed FM The manufacturer is added based on
United Kingdom PO BOX 67716 RIYADH Poto –Electric smoke detector model S approved. confirmation by Industrial Security Sector
11517 C2011 /Ind-ustrial Sec-urity Perform-ance Depart-ment
SHIELD FIRE SAFETY & SECURITY LTD TEL : 0112824444 Heat Detector S-C2013 Standard Mana-ger as per email mess-age of
S25191 Eng Selva. mounting base S-c2001Abort switich Jan-uary,16,2017”
REDBURN HOUSE S111R AB
2A TONBRIDGE ROAD Fire Alarm Bell FB-1000C6
ROMFORD, ESSEX RM3 8QE UNITED
KINGDOM

Phone - Tel : +441708077730


Email ID - [email protected]
Website - ww.shieldglobal.com

Hochiki America Corporation Engineering Field Est. Addresable (Fire net seies ) & UL Listed FM The manufacturer is added based on
United States Agil Alattas Conventional (HCA seies)Fire Alarm & approved. confirmation by Industrial Security Sector
Phone : 02-6579028 Detection Systems :- /Industrial Security Performance Department
7051 Village Drive, Suite 100 Buena Fax : 026579028 • Fire Control Panels. Manager as per email message of
Park, CA 90621-2268 [email protected] • Gas Extinguishing Control Panels. January,16,2017”.
• Fire Detection & Alarm Devices.
Phone - Phone : 714/522-2246
Email ID -
[email protected]
Website - WWW.Hochiki.com

Total = 9

46. 1 Page 741 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SAFETY AND SECURITY EQUIPMENT


46. 2
FIRE FIGHTING WATER PUMPS- FIRE WATER PUMPS & ACCESSORIES Applicable Standards: 90-TMSS-02

Saudi Mechanical Industries Co. Saudi Mechanical - Vertical Turbine Fire Water Pump PQ Letter
Saudi Arabia Industries Co. – rating up to 2500 GPM. Based on S&SD letter# 20-01597-30504401
Street No. 234, Second - Split Case Fire Pumps – rating up dated September 06, 2020, the manufacturer is
Plant -Riyadh – Saudi Arabia Industrial City. to 7500 GPM prequalified for FIRE WATER PUMPS as
P.O. BOX 59799 RIYADH - End Suction Fire Pumps – rating confirming to National Grid SA specification #
Street No. 234, Second Industrial City. 11535 up to 750 GPM 90-TMSS-02, with the following conditions:
P.O. BOX 59799 RIYADH 11535 00966 11 265 1979 WARRANTY
[email protected] • (10) years Extended Warranty shall be
Riyadh applicable for the offered FIRE WATER PUMPS to
be supplied to SEC/National Grid SA as confirmed
Contact Person - Alaa Alkhatatbeh through Letter # Nill dated Nill.
Phone - 00966 11 265 1979 Type Test
Email ID - [email protected] • All type tests for SVC (TCR/TSC) supplied to
Contact Person Email ID - SEC shall be conducted in presence of three (3)
[email protected] SEC/National Grid SA engineers & one (1) SEC
Website - www.smi.com.sa approved independent inspection agency
Inspector, all the related costs for witnessing the
tests will be borne by the manufacturer. This
was confirmed by NR Electric Co., Ltd.- China
through their letter # GJYX20200507_XG01,
dated May 07,2020.
• All type tests for Valves Cooling system
supplied to SEC shall be conducted in presence
of three (3) SEC/National Grid SA engineers &
one (1) SEC approved independent inspection
agency Inspector, all the related costs for
witnessing the tests will be borne by the
manufacturer. This was confirmed by NR Electric
Co., Ltd.- China through their letter #
GJYX20200507_XG02, dated May 07,2020.

AURORA LOCAL AGENT –SAUDI PUMP >= 500 GPM


United States

Website - http://www.aurora.com/

46. 2 Page 742 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

FAIRBANK MORSE
United States LOCAL AGENT –SAUDI PUMP >=500GPM

Website -
http://www.fairbanksmorse.com/

FLOWAY
United States

Website -
http://www.weiroilandgas.com/weirw
eb/oilandgas/home.nsf

PEERLESS LOCAL AGENT –SAUDI PUMP >=500GPM


United States

Website -
http://www.peerlesspump.com/

PETTERSON
United States

Website -
http://www.ie.pattersonpumps.com/

REDDY BUFFALOU
United States

Website - http://www.rbpump.com/

WORTHINGTON LOCAL AGENT –SAUDI PUMP >=500GPM


United States

Website -
http://www.worthington-biochem.com/

XYLEM WATER SYSTEM Previously ITT


United States

Plant -8200 North Austin Avenue


Morton Grove, Illinois 60053

Illinois

46. 2 Page 743 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 9

SAFETY AND SECURITY EQUIPMENT


46. 3
PORTABLE / MOBILE Applicable Standards: 90-TMSS-03

SFFECO
Saudi Arabia

2ND INDUSTRIAL AREA


AL-KHARJ RD
PO BOX 58469
RIYADH, 11515 SAUDI ARABIA

Contact Person - Ibrahim Tumar


Phone - Te :0112650070
Email ID - [email protected]
Website - http://www.sffeco.com/

HEBA FIRE & SAFETY EQUIP CO LTD


Saudi Arabia

Jalawia, King Saud Street, Next To


Toyota Showroom. P.O. Box 404,
Dammam 31411, Kingdom Of Saudi
Arabia.

Phone - (+966) 3 8420840 Fax: (+966)


3 8416790
Email ID - [email protected]

Total = 2

SAFETY AND SECURITY EQUIPMENT


46. 4
PORTABLE FIRE EXTINGUISHER, CO2 TYPE Applicable Standards: 90-TMSS-03

ANSUL LOCAL AGENT AL-BILAD >=5 LBS


United States

Website - https://
http://www.ansul.com/en/home.asp

46. 4 Page 744 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

KIDDE >=5 LBS


United States

Website - http://www.kiddeus.com/

SENTRY LOCAL AGENT AL-BILAD >=5 LBS


United States

Website -
http://www.sentry-equip.com/display/r
outer.aspx

Total = 3

SAFETY AND SECURITY EQUIPMENT


46. 5
PORTABLE FIRE EXTINGUISHER, DRY CHEMICAL TYPE Applicable Standards: 90-TMSS-03

ANSUL LOCAL AGENT AL-BILAD >=2 LBS


United States

Website - https://
http://www.ansul.com/en/home.asp

SENTRY LOCAL AGENT AL-BILAD >=2 LBS


United States

Website -
http://www.sentry-equip.com/display/r
outer.aspx

Total = 2

SAFETY AND SECURITY EQUIPMENT


46. 6
PORTABLE FIRE EXTINGUISHER, WATER TYPE Applicable Standards: 90-TMSS-03

SENTRY LOCAL AGENT AL-BILAD >=2.5 LBS


United States

Website -
http://www.sentry-equip.com/display/r
outer.aspx

46. 6 Page 745 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Total = 1

SAFETY AND SECURITY EQUIPMENT


46. 7
FOAM SYSTEM -FOAM SYSTEM & ACCESSORIES Applicable Standards: 90-TMSS-05

HILTI INTERNATIONAL, Hilti construction Hilti Saudi Arabia P.O FIRESTOP PRODUCTS; UL Listed FM The manufacturer is added based on
chemicals ,Div.of Hilti Inc. box 286701 Firestop Sealants, firestop Foams, approved. confirmation by Industrial Security Sector
United States Riyadh11323 Firestop collars & Wraps ,Firestop /Industrial Security Performance Department
T: 0114608974 Mortars & Boards, Firestop cast in Manager as per email message of
5400 122nd East Ave Fax: 0114606255 Devices ,Firestop Blocks ,Plugs January,16,2017”.
Tusla ,OK 74146 Mobile : 0504657548 ,Cushions. Fire Protection Coatings &
abusheikha@ hilti.com Fire stop Transit Systems.
WWW.hilti.sa

ANGUS
United Kingdom

Website -
http://www.angusfire.co.uk/utcfs/Temp
lates/Pages/Template-46/0,8060,pageId
%3D1260%26siteId%3D404,00.html

CHEMGUARD LOCAL AGENT NAFISCO


United States

Website - http://www.chemguard.com/

NATIONAL FOAM LOCAL AGENT HEBA


United States

Website -
http://www.kidde-fire.com/utcfs/Templ
ates/Pages/Template-50/0,8061,pageId
%3D3513%26siteId%3D465,00.html

Total = 4

HVAC Units
47. 1
HVAC Units Applicable Standards: 73-TMSS-01

47. 1 Page 746 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

JOHNSON CONTROLS (AL SALEM


YORK SERVICES)
Saudi Arabia

Lotus Building, Madinah Road, City :


Jeddah Postal/Zip Code : 15019 Saudi
Arabia

Phone - (+966-12) 690 0999 Fax :


(+966-12) 690 0909
Website - Website :
http://www.johnsoncontrols.com.sau?

ZAMIL AIR CONDITIONERS


Saudi Arabia

First Industrial City P.O.Box 44493, P.


O. Box 14440, Dammam 31424, Saudi
Arabia Dubai, U.A.E

Phone - (+966 13) 847 3333 , Tel :


(+971 4) 294 0424 Ext 212,Customer
Service: 92 0000 468 (K.S.A. only),Fax
: (+966 13) 847 1904,Fax : (+971 4)
294 0434
Email ID - [email protected]
Website - http://www.zamilac.com

ARABIAN AIR CONDITIONING


COMPANY LTD. & CARRIER SAUDI
SERVICE CO. LTD.
Saudi Arabia

P.O. Box 9784, Riyadh-11423, Saudi


Arabia.

Phone - +966 11 491 1333, Fax: +966


11 491 0919
Email ID - [email protected]

47. 1 Page 747 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

TRANE
Saudi Arabia

Head Office, Jeddah H.Q.

Phone - +966-0555591344,: 6171199 /


6719222 , Toll Free 800 244 0123,Fax :
6758185

SKM AIR CONDITIONING LLC


United Arab Emirates

Head Office P.O.Box 6004 Sharjah-Uae


Cr 2203 Sharjah

Phone - +971 6 5347347,Fax # +971 6


5349292
Email ID - E-mail [email protected]
Website - Website http://www.skm.ae

GOLDEN STARS FACTORY (HACE)


Saudi Arabia

P.O.Box 2625 Riyadh 11461-Saudi


Arabia

Phone - +966-11 2651500, Fax #


+966-11 2651521
Email ID - E-mail [email protected]

PETRA
JORDAN

P.O.Box 141351 Amman 11814 Jordan


Factory

Phone - +962 6 4051055, Fax # 962 6


4051228 Marketing 962 6 5531508, Fax
# 9666222 6 5531513 International
Sales 962 6 4051425, Fax # 962 6
4051248

Total = 7

47. 1 Page 748 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HVAC Control Panel


48. 1
HVAC Control Panel Applicable Standards: 73-TMSS-01

SAUTER MIDDLE EAST SAUTER


MIDDLE EAST FZC (JOINT VENTURE)
United Arab Emirates

Po Box: 7969 Ae -Saif Zone Sharjah

Phone - +971 6 557 8404,Fax +971 6


557 8405
Website -
http://www.sauter-controls.com

SETRA (SAUDI ELECTRONIC TRADING


COMPANY)
Saudi Arabia

Head Office P.O. Box: 60712, Riyadh


11555, Saudi Arabia

Phone - +966 11 461 6141, +966 11 206


5622, Fax: +966 11 463 3297, Fax:
+966 11 206 5611
Email ID - [email protected]

HONEYWELL HONEYWELL MIDDLE


EAST EZE
United Arab Emirates

P.O.Box 18530, Office N. LB08,199 ,


Jebal Ali, Dubai-UAE

Phone - +971 4 8073200,Fax # +971 4


8831611

48. 1 Page 749 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SELA-PASS (POWER AUTOMATION &


SAFETY SYSTEMS)
Saudi Arabia

(Head Office) P.O Box: 40388, Jeddah


21499 Al Harth Center - Abdul Rehman
Al-Sudairi St. Al Salamah District
Kingdom Of Saudi Arabia

Phone - (+966) 12 691 5777,Fax:


(+966) 12 257 2320
Email ID - [email protected]

48. 1 Page 750 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ZAMIL AIR CONDITIONING AND ELECTRICAL FUTURE PQ Letter


REFRIGERATION SERVICES CO. CONTRACTING EST.
Saudi Arabia P.O. BOX 30240 RIYADH Based on S&SD letter #MPQ348417949-Class 1
11477 KSA (b) - 2017 , dated February 11, 2020, the
Plant -AL DAMMAM 0112705230 manufacturer M/S ZAMIL AIR CONDITIONING
abdullah@electricalfutur AND REFRIGERATION SERVICES CO., Dammam,
1ST INDUSTRIAL CITY PO BOX 14440 e.co KSA, is included in the List of Technically
DAMMAM 31424 Approved Manufacturers (LOTAM) of
SEC/National Grid SA for HVAC CONTROL
AL DAMMAM PANELS as per 73-TMSS-01, Rev. 01, subject to
the following conditions:
Contact Person - RASHID ALI
Phone - (+966 13) 847 3333
Email ID - [email protected] Warranty:
Contact Person Email ID - Extended guarantee/ warranty to SEC/ National
[email protected] Grid SA for the proposed HVAC CONTROL
Website - https://www.zamilac.com/ PANEL in respect of the defects due to design ,
manufacturing, installation, and workmanship for
a period of Ten (10) years from the date of
Provisional Acceptance Certificate (PAC) as
agreed by the manufacturer through their letter #
Nil, dated 30/12/2019.

• The manufacturer is not allowed to quote for


any SEC/National Grid SA, project/purchase
order whenever there is change in plant location
& change in design, till evaluated and approved
by SEC/National Grid SA.

• Whenever there is a change of your authorized


contact person, SEC/National Grid SA shall be
informed with new contact details to update our
database.

Total = 5

Fire Protection Control Panel


49. 1
Fire Protection Control Panel Applicable Standards: 90-TMSS-01

49. 1 Page 751 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HEBA FIRE & SAFETY EQUIP CO LTD


Saudi Arabia

Jalawia, King Saud Street, Next To


Toyota Showroom. P.O. Box 404,
Dammam 31411, Kingdom Of Saudi
Arabia.

Phone - (+966) 3 8420840 Fax: (+966)


3 8416790
Email ID - [email protected]

HONEYWELL HONEYWELL MIDDLE


EAST EZE
United Arab Emirates

P.O.Box 18530, Office N. LB08,199 ,


Jebal Ali, Dubai-UAE

Phone - +971 4 8073200,Fax # +971 4


8831611

Total = 2

Dry Type Transformers, 36kV Primary


50. 1
Dry Type Transformers, 36kV Primary Applicable Standards:

SIEMENS
GERMANY

Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany

Phone - +49 (911) 433 8321


Website -
www.siemens.com/ingenuityforlife

50. 1 Page 752 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ABB ELECTRICAL INDUSTRIES CO. LTD


(ABB/AEIL)
Saudi Arabia

Plant -2Nd Industrial Area, Corner No.


61, 224 Street Riyadh

Saudi Arabia

Contact Person - Mr. Naiem Sharqaui


Phone - +966-0504 206 711
Email ID - [email protected]
Website - http://www.abb.com.sa/

WESCOSA
Saudi Arabia

Plant -Dammam , Saudi Arabia

First Industrial City of Dammam, P.O.


Box 2389, Dammam 31451, Saudi
Arabia

Contact Person - +966500594704


Phone - +966138100234 Ext 3267
Email ID - [email protected] ,
[email protected]
Website - http://www.wescosa.com/

Total = 3

Dry Type Transformers, 36kV Primary


50. 2
Compact Substation: 69kV Primary, 13.8kV or 34.5kV Secondary Applicable Standards:

ABB (BBC SECHERON)


SWITZERLAND

Geneva, Switzerland

50. 2 Page 753 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

CG POWER SYSTEMS On Hold


BELGIUM

Website - http://www.pauwels.com/

Total = 2

Dry Type Transformers, 36kV Primary


50. 3
Compact Substation – 110-132kV, 13.8kV or 34.5kV Secondary Applicable Standards:

ABB ( T& D)
United States

Plant -United States

Website - http://www.abb.us/

Total = 1

Telecommunication Integration facilities


51. 1
Telecommunication Integration facilities Applicable Standards:

SIEMENS PQ Letter:
Saudi Arabia Based on S&SD letter # 14-08957-02-30504401
dated 17 December 2014, the manufacturer is
Plant -Jeddah prequalified for Integration (Assembly) and
Testing of Communication Equipment from
Website - http://www.siemens.com.sa Original Equipment Manufacturer (OEM) type
tested and approved by National Grid SA as
conforming to National Grid SA specification #
48-TMSS-06, Rev.0 with the following condition:

WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Fe/08/14 dated October 10, 2012.

51. 1 Page 754 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

SYSTEM HOUSE FACTORY FOR Local Mfr. Only OEM prequalified Telecom OEM type tested PQ Letter
ELECTRIC PANELS (SEP,) located at Unit No. 45, equipment for which care services Telecom equipment
Saudi Arabia Street 201 Second (Managed Services) agreement has and approved by Based on S&SD Letter # MPQ884220352-Class
Industrial City Building been signed by SEP with OEMs for SEC/National Grid I(a)-2020 dated September 28, 2022, the
Plant -New Industrial Area No:1, Riyadh No. 6687, Riyadh 14431 future firmware and soft/hardware SA . manufacturer is prequalified as
+966 11 4980822 Ext upgradation or any technical support Telecommunication Integration facilities only for
P O Box 355950, New Industrial Area 601 required in future for particular telecom integration (assembly) & testing of Telecom
No:2, Riyadh -11383 [email protected]. equipment to be integrated (assembled) equipment from original equipment manufacturer
sa [email protected] and Tested, and staff is certified (OEM) type tested and approved by SEC/National
Contact Person - Mr. Bruno Stocchi, trained for the particular Telecom Grid SA as conforming to National Grid SA
Muhannad Alshehri equipment by OEM. relevant Telecom equipment specification with the
Phone - +966- 0535754302 , +966- following conditions:
0505278491
Email ID - E-mail [email protected], Warranty:
[email protected] Aburajab, Ten (10) years extended warranty from the date
Contact Person Email ID - of PAC of the first turnkey project (in case of
[email protected] contract award) or date of first delivery (in case
of direct material supply order) as confirmed,
through their letter No.
SEP-Telecom-0003-PQ-20-08, dated August 12,
2020, shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

51. 1 Page 755 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALFANAR ELECTRICAL SYSTEMS Telecommunication integration facilities OEM type tested PQ Letter
Saudi Arabia for telecommunication system, Telecom equipment Based on S&SD Letter # 23-MPQ574820352
Telecommunication panels, and approved by dated October 5, 2023, the manufacturer is
Plant -3Rd Industrial Area, Al Kharaj Telecommunication equipment SEC/National Grid prequalified as Telecommunication Integration
Road, Riyadh Saudi Arabia SA. facilities only for integration (assembly) & testing
Only OEM prequalified Telecom of Telecom equipment from original equipment
Po Box 301 , Riyadh 11411 , North Righ equipment for which care services manufacturer (OEM) type tested and approved
Road Between Exit 5 & 6 Riyadh , (Managed Services) agreement has by SEC/National Grid SA as conforming to
Saudi Arabia been signed by M/s Al-Fanar with National Grid SA relevant Telecom equipment
Telecom Equipment OEMs for future specification with the following conditions:
Riyadh firmware and soft/hardware
upgradation or any technical support Warranty:
Contact Person - Sultan Alghamdi " VIP required in future for particular telecom Ten (10) years extended warranty from the date
key Account Manegr "; Saleh equipment to be integrated (assembled) of PAC of the first turnkey project (in case of
Almehaijeen "Projects Sales Engineer " and Tested, and staff is certified contract award) or date of first delivery (in case
Phone - 920006111 trained for the particular Telecom of direct material supply order) as confirmed,
Contact Person Email ID - equipment by OEM. through their letter No.Nill , dated, Oct. 05, 2023
[email protected]; shall be applicable for the equipment to be
[email protected] supplied to SEC/National Grid SA.
Website - www.alfanar.com

51. 1 Page 756 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

ALSTOM GRID AUTOMATION UNIT PQ Letter


COGELEX Based on S&SD letter # 15-00240-02-30504401
Saudi Arabia dated March 03, 2015, the manufacturer is
prequalified for Integration (assembly) & Testing
Plant -Jeddah , Saudi Arabia of Communication & SCADA equipment as
conforming to National Grid SA specification #
PO Box 8535 Jeddah 21492 Saudi 48-TMSS-06, Rev.0 with the following conditions:
Arabia
CONDITION:
Contact Person - Mr.Firas Salman ,Unit Only for integration (assembly) & testing of
Commercial Director –NMs communication & SCADA equipment from original
Phone - +966-02-6518610 ,6513476 equipment manufacturer (OEM) type tested and
Contact Person Email ID - approved by SEC/National Grid SA.
[email protected]
Website - http://www.Alstom.com WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #RN-2013-12-3 NMS/1 dated December 03,
2013.

51. 1 Page 757 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.

Plant -2Nd Industrial Area,Riyadh, Previous name was ABB Electrical Industries
Company Ltd, and changed to ABB Contracting
Po Box 325841 Riyadh,11371 KSA Co. Ltd based on S&SD letter
#20-01681-30504401 dated October 01, 2020
Contact Person - Mr. Essam
Bashraheel & Mr. Ahmed Abubasha
Phone - Tel:+966-011-476-2644
Fax:+966-011-476-9622 PQ Letter
Contact Person Email ID - Based on S&SD letter # 15-01367-01-30504401
[email protected] dated 8th March-2015, the manufacturer is
& prequalified for ‘Integration (Assembly) & Testing
[email protected] of Communication & SCADA Equipment from
Original Equipment Manufacturer (OEM) type
tested & approved by SEC/National Grid as
conforming to National Grid SA specification #
48-TMSS-06, Rev.0 with the following condition:

WARRANTY:
• Ten (10) years extended warranty in respect of
the defects due to design, manufacturing and
workmanship, as confirmed by the manufacturer
through their letter # PSN/TLE/0517/09/2014,dt:
15/09/2014.

51. 1 Page 758 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Innovative Systems Co. Ltd. Telecommunication integration facilities OEM type tested PQ Letter
Saudi Arabia for telecommunication system, Telecom equipment Based on S&SD letter # MPQ1112920352 dated
Telecommunication panels, and approved by February 19, 2024, the manufacturer is
Plant -Riyadh KSA Telecommunication equipment SEC/National Grid prequalified for Telecommunication Integration
and Testing Facility, with the following conditions:
Innovative Systems - Street No. 20 Only OEM prequalified Telecom
Along Street 59 Al Kharj Industrial City equipment for which care services WARRANTY
Riyadh Saudi Arabia (Managed Services) agreement has Ten (10) years extended warranty/guarantee to
been signed by M/s Innovative SEC/National Grid SA for the Telecom Cabinets
Riyadh Systems with Telecom Equipment and Racks in respect of the defects due to
OEMs for future firmware and design, manufacturing, installation and
Contact Person - Kamal Al Muhanna, soft/hardware upgradation or any workmanship from the date of Provisional
CEO Rameez Mulki Substation technical support required in future for Acceptance Certificate (PAC) of the first turnkey
Automation BU Manager particular telecom equipment to be project (in case of contract award) or from the
Phone - +966114608160/61 integrated (assembled) and Tested, date of first delivery (in case of direct material
Email ID - [email protected] and staff is certified trained for the supply order), as confirmed by the manufacturer,
[email protected] particular Telecom equipment by OEM. through their Letter Ref. # AA072523 dated
25.07.2023.

Total = 6

VAR COMPENSATION SYSTEM


52. 1
STATIC VAR COMPENSATOR (SVC) Applicable Standards: 59-TMSS-01,59-TMSS-02,TES-P-119.42

52. 1 Page 759 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

NR Electric Co., Ltd. Control Systems PCS-9580 & PCS-9510 To be conducted PQ Letter
CHINA Company during first project Based on S&SD letter# 20-01464/01-030504401
3364 Umar Ibn Abdul dated August 19, 2020, the NR Electric Co., Ltd. -
Plant -Nanjing, China Aziz Rd  Az Zahra, China is prequalified for Static Var Compensator
Unit No 6, Ar Riyadh (SVC) System PCS-9580 & Valves Cooling
69 Suyuan Avenue, Nanjing 211102, 12815  6238, System PCS-9510 as confirming to National Grid
China Kingdom of Saudi Arabia SA specification # 59-TMSS-01 & 59-TMSS-02,
+ 966 11 408 8010 with the following conditions:
Nanjing [email protected]
M.SA WARRANTY
Contact Person - Li Xueguang • Ten (10) years Extended Warranty shall be
Phone - +86 25 8717 8888 applicable for the offered SVC (TCR/TSC Valves)
Email ID - [email protected] System to be supplied to SEC/National Grid SA as
Contact Person Email ID - confirmed through Letter #
[email protected] GJYX20200507_LXG03 dated May 07,2020.
Website - www.nrec.com • Ten (10) years Extended Warranty shall be
applicable for the offered Valves Cooling System
to be supplied to SEC/National Grid SA as
confirmed through Letter #
GJYX20200507_LXG04 dated May 07,2020.

Type Test
• All type tests for SVC (TCR/TSC) supplied to
SEC shall be conducted in presence of three (3)
SEC/National Grid SA engineers & one (1) SEC
approved independent inspection agency
Inspector, all the related costs for witnessing the
tests will be borne by the manufacturer. This
was confirmed by NR Electric Co.,- Ltd.- China
through their letter # GJYX20200507_LXG01,
dated May 07,2020.
• All type tests for Valves Cooling system
supplied to SEC shall be conducted in presence
of three (3) SEC/National Grid SA engineers &
one (1) SEC approved independent inspection
agency Inspector, all the related costs for
witnessing the tests will be borne by the
manufacturer. This was confirmed by NR Electric
Co., Ltd.- China through their letter #
GJYX20200507_LXG02, dated May 07,2020.

Others

52. 1 Page 760 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

All major components of Static Var Compensator


(SVC) system will be supplied from SEC/National
Grid SA approved manufacturer list as confirmed
by NR Electric Co.,Ltd. – China through their letter
# GJYX20200622_LXG03R1, dated July 24,2020.

Total = 1

VAR COMPENSATION SYSTEM


52. 2
Static Synchronous Compensator (STATCOM) Applicable Standards: 59-TMSS-03

NR Electric Co., Ltd. Control Systems PCS 9583 To be conducted PQ LETTER


CHINA Company during first project. Based on S&SD letter# MPQ676321653 dated
3364 Umar Ibn Abdul November 12, 2020, the manufacturer is
Plant -NR Electric Power El - 328 Wuyi Aziz Rd  Az Zahra, prequalified for Static Synchronous Compensator
Road Wujin Changzhou China PRC Unit No 6, Ar Riyadh (STATCOM) PCS9583 as confirming to National
12815  6238, Kingdom Grid SA specification # 59-TMSS-03, with the
NR Electric Power El - 328 Wuyi Road of Saudi Arabia following conditions:
Wujin Changzhou China PRC + 966 11 408 8010
[email protected]
Changzhou M.SA WARRANTY
Ten (10) years extended warranty from the date
Contact Person - Gavin Li of PAC of the first turnkey project (in case of
Contact Person Email ID - contract award) or date of first delivery (in case
[email protected] of direct material supply order), as confirmed,
through their Letter No. GJYX20190720_LXG01
dated July 15,2019 and Letter No.
GJYX20200507_LXG04 dated May 07,2020 shall
be applicable for the equipment to be supplied to
SEC/National Grid SA.

TYPE TESTS
Manufacturer through Letter No.
GJYX20200622_LXG01 dated June 22,2020 and
Letter No. GJYX20200507_LXG02 dated May
07,2020 confirmed in writing to conduct the type
tests during first project in presence of three (3)
SEC/National Gris SA Engineers and one (1)
SEC/National Grid SA approved inspector. All the
cost pertaining to the type tests shall be borne by
the manufacturer.

52. 2 Page 761 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

HYOSUNG HEAVY INDUSTRIES STATCOM SMART QTM PQ Letter


CORPORATION (HICO) Based on S&SD letter # 21-00433/01-030504401
SOUTH KOREA dated April 01, 2021, Hyosung – South Korea is
prequalified for Static Synchronous Compensator
Plant -Republic of Changwon, Korea (STATCOM), as confirming to National Grid SA
specification # 59-TMSS-03, with the following
Eric Rhie, 450, Gongdeok-Dong, conditions:
Mapo-Gu, Seoul , Korea
Tel:82-707-6180 Type Tests
Confirmation as per Hyosung letter # Nil, dated
Contact Person - Mr. Jason Kang; Sale 04.09.2022 to conduct the type tests of
Manager & Mr. Young Kim; Sales STATCOM as per IEC 62927 to be supplied to
Manager SEC/National Grid SA during the first awarded
Contact Person Email ID - project.
[email protected] ,
[email protected] WARRANTY
Website - Ten (10) years extended warranty from the date
http://www.hyosung.co.kr/eng/index.js of PAC of the first turnkey project (in case of
p?, www.hyosung.com contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter No. Nil, dated September 04,
2020 shall be applicable for the equipment to be
supplied to SEC/National Grid SA.

Total = 2

Paints and Coatings


54. 1
Corrosion Protective Paint For Hot Dip Galvanized Steel Structures Applicable Standards: 78-TMSS-13

54. 1 Page 762 of 763


SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED

Jotun Saudia Co. Ltd. Corrosion Protective Paint Norner Test Report # PQ Letter
Saudi Arabia NO230118 dated Based on S&SD letter reference #
Primer : Jotamastic 90 MIO February 10, 2023 23-01192-01-30504401 dated August 21, 2023,
Plant -Yanbu Intermediate : Jotamastic 90 the manufacturer is prequalified for Corrosion
Top : Optima UHS AlFuttaim element Protective Paint for hot dip galvanized steel
7th Street, Light Industrial Park, Test Report # structures up to 380kV conforming to National
Royal Commission WR22-06104 (Rev. Grid SA specification # 78-TMSS-13, Rev.0, with
P.O. Box 30154, Yanbu 41912 1) dated January 10, the following conditions:
2023
Contact Person - Mr. Samy Fathy Ali WARRANTY
(Country Sales Manager ) Twenty (20) years extended warranty from the
Phone - Phone:+966 9200 29988; +966 date of PAC of the first turnkey project (in case
12 6350535 Ext-2610; +966 549010020 of contract award) or date of first delivery (in
Email ID - [email protected]; case of direct material supply order), as
http://www.jotun.com/me confirmed, through their Letter #
Contact Person Email ID - E.I.DMM.01/17/08/2023 dated August 17, 2023
[email protected]; shall be applicable for the equipment to be
http://www.jotun.com/me supplied to SEC/National Grid SA.

Sigma Paints S.A. Ltd. Corrosion Protective Paint Wimpey laboratories PQ Letter
Saudi Arabia Test Report # WD-R Based on S&SD letter reference #
Primer : Sigmafast 278 MIO -220408-0367 dated 23-01187-30504401 dated June 14, 2023, the
Plant -Dammam Intermediate : Sigmafast 278 July 01, 2022 manufacturer is prequalified for Corrosion
Top : PSX 700 Protective Paint for hot dip galvanized steel
66 St, Industrial Area No 2, Dammam Al Hoty Stanger Test structures up to 380kV conforming to National
34333, Saudi Arabia Report # Grid SA specification # 78-TMSS-13, Rev.0, with
KHMAD221831 the following conditions:
Contact Person - Mr. Mohamed Ali -R2-V2 dated July
(Technical Sales Manager) 18, 2022 WARRANTY
Phone - +966 13 847 1333 Ext-1362 Twenty (20) years extended warranty from the
Email ID - [email protected] date of PAC of the first turnkey project (in case
Website - www.sigmapaints.com of contract award) or date of first delivery (in
case of direct material supply order), as
confirmed, through their Letter # Nil dated
September 26, 2021 shall be applicable for the
equipment to be supplied to SEC/National Grid SA.

Total = 2