BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS

6.1 -3-STOREY SHOP OFFICE (27'x75') END LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

INTERNAL ELECTRICAL AND TELEPHONE WORKS (ALL


PROVISIONAL)

3-STOREY SHOP OFFICE (27'x75') END LOT


(All as per drawing and specification)

To supply and install of the following c/w necessary accessories


and works for complete installation and operation:-

INTERNAL ELECTRICAL WIRING

All wiring shall be in Heavy Duty High Impact PVC concealed


conduit (Latest Suruhanjaya Tenaga & Jab. Bomba Approved Type)

All switches and socket outlets faceplate must be from Suruhanjaya


Tenaga and SIRIM latest approved type.

A Ceiling/Wall Lighting point using 2 x 1.5sq.mm PVC + E cable c/w Nos 40


10A SP Ivory Flushed Switch.

B Emergency Light point using 2 x 1.5sq.mm PVC + E cable (without Nos 15


switch)

C Keluar Sign Light point using 2 x 1.5sq.mm PVC + E cable (without Nos 10
switch)

D Ceiling fan point using 2 x 1.5sq.mm PVC + E cable c/w hook, 5A Nos 7
SP ivory flushed switch and fan wall regulator point.

E 13A Switch Socket Outlet point using 2 x 2.5sq.mm PVC + E cable Nos 25
c/w 13A 3 Pin Ivory Color Flushed Switch Socket Outlet. (1 gang)

F 13A Switch Socket Outlet Point using 2 x 2.5sq.mm PVC + E cable Nos 1
c/w 13A 3 Pin Ivory Flushed Switch Socket Outlet (1 gang) and 20A
Ivory Flushed Switch With LED Indicator Light.

G Air Cooled Split Unit point using 2 x 4.0sq.mm PVC + E cable c/w Nos 10
15A 3 Pin Ivory Flushed Switch Socket Outlet (1 gang) and 15A
Ivory Flushed Switch With LED Indicator Light.

H 2 nos 32mm Dia. Heavy Duty High Impact PVC Concealed Conduit Lot 3
for Solor System Point From Roof level to Every DB at Ground,
First and Second Floor

J Exhaust Fan point using 2 x 4.0sq.mm PVC + E cable c/w 15A 3 Nos 2
Pin Ivory Flushed Switch Socket Outlet (1 gang) and 15A Ivory
Flushed Switch With LED Indicator Light.

B6.1/1/Add.2 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.1 -3-STOREY SHOP OFFICE (27'x75') END LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

LUMINAIRES AND FITTINGS

All luminaires must be from Jabatan Bomba latest approved type.

A 1 x 13W PLC Tube - Emergency Light c/w 3 Hrs Back-up Battery Nos 15
(BOMBA approved type) - Nickel Metal Hydride (NI-MH) Type

B LED Fluorescent Tube - Keluar Sign c/w 3 Hrs Back-up Battery Nos 10
(BOMBA approved type) - Nickel Metal Hydride (NI-MH) Type

DISTRIBUTION BOARD & TNB METER PANEL

All Distribution Board housing, circuit protective devices and


accessories must be from Suruhanjaya Tenaga & SIRIM latest
approved type

C 60A TPN DB (Wall Mounted Metalclad Type with Full Front Cover) Set 1
c/w Switch Fuse, RCCB, MCB's, Surge Protective Device (SPD),
etc) - Ground Floor

D 60A TPN DB (Wall Mounted Metalclad Type with Full Front Cover Set 1
c/w Switch Fuse, RCCB, MCB's, Surge Protective Device (SPD),
etc) - First Floor

E 60A TPN DB (Wall Mounted Metalclad Type with Full Front Cover Set 1
c/w Switch Fuse, RCCB, MCB's, Surge Protective Device (SPD),
etc) - Second Floor

F 60A TPN TNB Meter Panel c/w wiring , Cut-out & Neutral Link and Set 3
accessories, etc. (Wall Mounted Metalclad & Hard Fiber Base Type)
at TNB Meter Compartment

G 650mm (L) x 650mm (W) x 650mm (H) of Reinforce Concrete (RC) Lot 1
Electrical Service Manholes complete with Heavy Duty RC Flushed
Cover, Hole Opening for 4 nos of 150mm Dia GI Ducting c/w 4 nos
150mm Dia. GI Ducting (Class C) extended beyond perimeter drain
and apron slab

H 1 no. x 150mm Dia. HDPE Double Wall Corrugated Underground Lot 1


Ducting from bottom TNB Meter Panel and extended beyond drain
and after infront of road curb.

B6.1/2 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.1 -3-STOREY SHOP OFFICE (27'x75') END LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

SUBMAIN WIRING

Internal submain wiring shall be runs in appropriate size of metal


trunking c/w earth copper bridge, bracket, necessary accessories
and works for complete installation and operation :-

A 4C 25sq.mm PVC + E Submain Cabling from TNB Meter Panel Lot 1


Compartment (Ground Floor) to 60A TPN Distribution Board at
Ground Floor (Shop) in Metal Trunking

B 4C 25sq.mm PVC + E Submain Cabling from TNB Meter Panel Lot 1


Compartment (Ground Floor) to 60A TPN Distribution Board at First
Floor (Office) in Metal Trunking

C 4C 25sq.mm PVC + E Submain Cabling from TNB Meter Panel Lot 1


Compartment (Ground Floor) to 60A TPN Distribution Board at
Second Floor (Office) in Metal Trunking

EARTHING SYSTEM

Complete supply, install, testing and commissioning of the following Lot 3


with full compliance to latest Suruhanjaya Tenaga (ST) specification
and regulation comprising of the following :-

i) 1 x 16sq.mm PVC Green Cable in conduit from each individual


ii) Heavy Duty Concrete Earth Chamber
iii) Copper rod for earthing c/w double copper cable clamp
* Earth Resistance Test must be achieved below than 5 Ohm

SUBMISSION AND LIAISON WITH TNB

Preparation and submission of TNB A-Form for Electricity Supply Lot 3


Connection c/w E-Application, Wiring Test Result, Form G & H,
paying processing fee payment and liason with TNB until getting
connection of Electricity Supply.

B6.1/3 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.1 -3-STOREY SHOP OFFICE (27'x75') END LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

INTERNAL TELEPHONE WIRING (UNIFI/FIBRE SYSTEM)

All wirings, equipment and accessories must be from TM latest


approved type.

A 8 Port Main Fibre Termination Board (FTB) and all necessary No 1


accessories at Ground Floor Staircase 1

B Fiber Wall Socket (FWS) and all necessary accessories Nos 3

C 8C Single Mode Fibre Optic Cable in Metal Trunking from Main Lot 1
FibreTermination Board (MFTB) at Corridor to Fibre Termination
Board (FTB) at Staircase 1 Ground Floor.

D 2C Single Mode Fibre Optic Cable in Heavy Duty High Impact PVC Lot 3
Concealed Conduit from Fibre Termination Board (FTB) at
Staircase 1 Ground Floor to Fibre Wall Socket (FWS) at Each
Level.

E Termination For All Single Mode Fibre Optic Cables from FWS LS
Individual Unit to FTB & MFTB c/w all necessary accessories.

F Preparation and submission of Acceptance OTDR Test For Fibre LS


Optic Cable

PORTABLE FIRE EXTINGUISHER

G 9kg ABC fire portable extinguisher c/w Jab. Bomba Certification. Nos 10

SUBMISSION OF DOCUMENTATION

H Submission of the following documentation (4 sets) :- Lot 1


i) Sub-Contractor Company Profile c/w valid registeration from
authorities and bodies.
ii) Shop Drawing /Proposed detail Construction Drawings.
iii) Catalogues, brochure of proposal material.
iv) Testing result form as per TNB/TM/ST/SKMM latest requirement.
v) As Built Drawing c/w Operation & Maintenance Manual and USB
Pendrive.

MECHANICAL VENTILATION
I
To supply, install, testing and commissioning of the following
exhaust fan system consist wall mounted/ceiling axial fan type as
per tender drawing and specification c/w supply G.I sheet duct and
return GI duct, flexible insulated duct, exhaust air grille, discharge
louvre, fan operation interlock with lighting switch / supports and
necessary accessories for complete installation and operation.

a) Toilet 1 & 2 - Ground Floor Lot 1


b) Toilet 1 - First Floor Lot 1

B6.1/4/Add.2 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.1 -3-STOREY SHOP OFFICE (27'x75') END LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

COLLECTION

B6.1/1/Add.2

B6.1/2

B6.1/3

B6.1/4/Add.2

6.1 -3-STOREY SHOP OFFICE (27'x75') END LOT (ALL


PROVISIONAL)

SUB-TOTAL TO SUMMARY FOR 1 UNIT X 1 UNIT

TOTAL SUMMARY FOR 2 UNITS X 2 UNITS

B6.1/5/Add.2 TO SUMMARY
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.2 - 3-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

INTERNAL ELECTRICAL AND TELEPHONE WORKS (ALL


PROVISIONAL)

3-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT


(All as per drawing and specification)

To supply and install of the following c/w necessary accessories


and works for complete installation and operation:-

INTERNAL ELECTRICAL WIRING

All wiring shall be in Heavy Duty High Impact PVC concealed


conduit (Latest Suruhanjaya Tenaga & Jab. Bomba Approved Type)

All switches and socket outlets faceplate must be from Suruhanjaya


Tenaga and SIRIM latest approved type.

A Ceiling/Wall Lighting point using 2 x 1.5sq.mm PVC + E cable c/w Nos 40


10A SP Ivory Flushed Switch.

B Emergency Light point using 2 x 1.5sq.mm PVC + E cable (without Nos 15


switch)

C Keluar Sign Light point using 2 x 1.5sq.mm PVC + E cable (without Nos 10
switch)

D Ceiling fan point using 2 x 1.5sq.mm PVC + E cable c/w hook, 5A Nos 7
SP ivory flushed switch and fan wall regulator point.

E 13A Switch Socket Outlet point using 2 x 2.5sq.mm PVC + E cable Nos 25
c/w 13A 3 Pin Ivory Color Flushed Switch Socket Outlet. (1 gang)

F 13A Switch Socket Outlet Point using 2 x 2.5sq.mm PVC + E cable Nos 1
c/w 13A 3 Pin Ivory Flushed Switch Socket Outlet (1 gang) and 20A
Ivory Flushed Switch With LED Indicator Light.

G Air Cooled Split Unit point using 2 x 4.0sq.mm PVC + E cable c/w Nos 10
15A 3 Pin Ivory Flushed Switch Socket Outlet (1 gang) and 15A
Ivory Flushed Switch With LED Indicator Light.

H 2 nos 32mm Dia. Heavy Duty High Impact PVC Concealed Conduit Lot 3
for Solor System Point From Roof level to Every DB at Ground,
First and Second Floor

J Exhaust Fan point using 2 x 4.0sq.mm PVC + E cable c/w 15A 3 Nos 2
Pin Ivory Flushed Switch Socket Outlet (1 gang) and 15A Ivory
Flushed Switch With LED Indicator Light.

B6.2/1/Add.2 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.2 - 3-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

LUMINAIRES AND FITTINGS

All luminaires must be from Jabatan Bomba latest approved type.

A 1 x 13W PLC Tube - Emergency Light c/w 3 Hrs Back-up Battery Nos 15
(BOMBA approved type) - Nickel Metal Hydride (NI-MH) Type

B LED Fluorescent Tube - Keluar Sign c/w 3 Hrs Back-up Battery Nos 10
(BOMBA approved type) - Nickel Metal Hydride (NI-MH) Type

DISTRIBUTION BOARD & TNB METER PANEL

All Distribution Board housing, circuit protective devices and


accessories must be from Suruhanjaya Tenaga & SIRIM latest
approved type

C 60A TPN DB (Wall Mounted Metalclad Type with Full Front Cover) Set 1
c/w Switch Fuse, RCCB, MCB's, Surge Protective Device (SPD),
etc) - Ground Floor

D 60A TPN DB (Wall Mounted Metalclad Type with Full Front Cover Set 1
c/w Switch Fuse, RCCB, MCB's, Surge Protective Device (SPD),
etc) - First Floor

E 60A TPN DB (Wall Mounted Metalclad Type with Full Front Cover Set 1
c/w Switch Fuse, RCCB, MCB's, Surge Protective Device (SPD),
etc) - Second Floor

F 60A TPN TNB Meter Panel c/w wiring , Cut-out & Neutral Link and Set 3
accessories, etc. (Wall Mounted Metalclad & Hard Fiber Base Type)
at TNB Meter Compartment

G 650mm (L) x 650mm (W) x 650mm (H) of Reinforce Concrete (RC) Lot 1
Electrical Service Manholes complete with Heavy Duty RC Flushed
Cover, Hole Opening for 4 nos of 150mm Dia GI Ducting c/w 4 nos
150mm Dia. GI Ducting (Class C) extended beyond perimeter drain
and apron slab

H 1 no. x 150mm Dia. HDPE Double Wall Corrugated Underground Lot 1


Ducting from bottom TNB Meter Panel and extended beyond drain
and after infront of road curb.

B6.2/2 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.2 - 3-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

SUBMAIN WIRING

Internal submain wiring shall be runs in appropriate size of metal


trunking c/w earth copper bridge, bracket, necessary accessories
and works for complete installation and operation :-

A 4C 25sq.mm PVC + E Submain Cabling from TNB Meter Panel Lot 1


Compartment (Ground Floor) to 60A TPN Distribution Board at
Ground Floor (Shop) in Metal Trunking

B 4C 25sq.mm PVC + E Submain Cabling from TNB Meter Panel Lot 1


Compartment (Ground Floor) to 60A TPN Distribution Board at First
Floor (Office) in Metal Trunking

C 4C 25sq.mm PVC + E Submain Cabling from TNB Meter Panel Lot 1


Compartment (Ground Floor) to 60A TPN Distribution Board at
Second Floor (Office) in Metal Trunking

EARTHING SYSTEM

Complete supply, install, testing and commissioning of the following Lot 3


with full compliance to latest Suruhanjaya Tenaga (ST) specification
and regulation comprising of the following :-

i) 1 x 16sq.mm PVC Green Cable in conduit from each individual


ii) Heavy Duty Concrete Earth Chamber
iii) Copper rod for earthing c/w double copper cable clamp
* Earth Resistance Test must be achieved below than 5 Ohm

SUBMISSION AND LIAISON WITH TNB

Preparation and submission of TNB A-Form for Electricity Supply Lot 3


Connection c/w E-Application, Wiring Test Result, Form G & H,
paying processing fee payment and liason with TNB until getting
connection of Electricity Supply.

B6.2/3 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.2 - 3-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

INTERNAL TELEPHONE WIRING (UNIFI/FIBRE SYSTEM)

All wirings, equipment and accessories must be from TM latest


approved type.

A 8 Port Main Fibre Termination Board (FTB) and all necessary No 1


accessories at Ground Floor Staircase 1

B Fiber Wall Socket (FWS) and all necessary accessories Nos 3

C 8C Single Mode Fibre Optic Cable in Metal Trunking from Main Lot 1
FibreTermination Board (MFTB) at Corridor to Fibre Termination
Board (FTB) at Staircase 1 Ground Floor.

D 2C Single Mode Fibre Optic Cable in Heavy Duty High Impact PVC Lot 3
Concealed Conduit from Fibre Termination Board (FTB) at
Staircase 1 Ground Floor to Fibre Wall Socket (FWS) at Each
Level.

E Termination For All Single Mode Fibre Optic Cables from FWS LS
Individual Unit to FTB & MFTB c/w all necessary accessories.

F Preparation and submission of Acceptance OTDR Test For Fibre LS


Optic Cable

PORTABLE FIRE EXTINGUISHER

G 9kg ABC fire portable extinguisher c/w Jab. Bomba Certification. Nos 10

SUBMISSION OF DOCUMENTATION

H Submission of the following documentation (4 sets) :- Lot 1

i) Sub-Contractor Company Profile c/w valid registeration from


authorities and bodies.
ii) Shop Drawing /Proposed detail Construction Drawings.
iii) Catalogues, brochure of proposal material.
iv) Testing result form as per TNB/TM/ST/SKMM latest requirement.
v) As Built Drawing c/w Operation & Maintenance Manual and USB
Pendrive.

MECHANICAL VENTILATION

J To supply, install, testing and commissioning of the following


exhaust fan system consist wall mounted/ceiling axial fan type as
per tender drawing and specification c/w supply G.I sheet duct and
return GI duct, flexible insulated duct, exhaust air grille, discharge
louvre, fan operation interlock with lighting switch / supports and
necessary accessories for complete installation and operation.
a) Toilet 1 & 2 - Ground Floor Lot 1
b) Toilet 1 - First Floor Lot 1

B6.2/4/Add.2 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.2 - 3-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

COLLECTION

B6.2/1/Add.2

B6.2/2

B6.2/3

B6.2/4/Add.2

6.2 - 3-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT


(ALL PROVISIONAL)

SUB-TOTAL TO SUMMARY FOR 1 UNIT X 1 UNIT

TOTAL SUMMARY FOR 2 UNITS X 2 UNITS

B6.2/5/Add.2 TO SUMMARY
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.3 - 2-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

INTERNAL ELECTRICAL AND TELEPHONE WORKS (ALL


PROVISIONAL)

2-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT


(All as per drawing and specification)

To supply and install of the following c/w necessary accessories


and works for complete installation and operation:-

INTERNAL ELECTRICAL WIRING

All wiring shall be in Heavy Duty High Impact PVC concealed


conduit (Latest Suruhanjaya Tenaga & Jab. Bomba Approved Type)

All switches and socket outlets faceplate must be from Suruhanjaya


Tenaga and SIRIM latest approved type.

A Ceiling/Wall Lighting point using 2 x 1.5sq.mm PVC + E cable c/w Nos 30


10A SP Ivory Flushed Switch.

B Emergency Light point using 2 x 1.5sq.mm PVC + E cable (without Nos 10


switch)

C Keluar Sign Light point using 2 x 1.5sq.mm PVC + E cable (without Nos 6
switch)

D Ceiling fan point using 2 x 1.5sq.mm PVC + E cable c/w hook, 5A Nos 6
SP ivory flushed switch and fan wall regulator point.

E 13A Switch Socket Outlet point using 2 x 2.5sq.mm PVC + E cable Nos 20
c/w 13A 3 Pin Ivory Color Flushed Switch Socket Outlet. (1 gang)

F 13A Switch Socket Outlet Point using 2 x 2.5sq.mm PVC + E cable Nos 1
c/w 13A 3 Pin Ivory Flushed Switch Socket Outlet (1 gang) and 20A
Ivory Flushed Switch With LED Indicator Light.

G Air Cooled Split Unit point using 2 x 4.0sq.mm PVC + E cable c/w Nos 7
15A 3 Pin Ivory Flushed Switch Socket Outlet (1 gang) and 15A
Ivory Flushed Switch With LED Indicator Light.

H 2 nos 32mm Dia. Heavy Duty High Impact PVC Concealed Conduit Lot 2
for Solor System Point From Roof level to Every DB at Ground,
First and Second Floor

B6.3/1 TO COLLECTION
BILL NO 6 - MECHANICAL AND ELECTRICAL WORKS
6.3 - 2-STOREY SHOP OFFICE (20'x75') INTERMEDIATE LOT (ALL PROVISIONAL)

ITEM
DESCRIPTION UNIT QTY RATE AMOUNT (RM)
NO.

LUMINAIRES AND FITTINGS

All luminaires must be from Jabatan Bomba latest approved type.

A 1 x 13W PLC Tube - Emergency Light c/w 3 Hrs Back-up Battery Nos 10
(BOMBA approved type) - Nickel Metal Hydride (NI-MH) Type

B LED Fluorescent Tube - Keluar Sign c/w 3 Hrs Back-up Battery Nos 6
(BOMBA approved type) - Nickel Metal Hydride (NI-MH) Type

DISTRIBUTION BOARD & TNB METER PANEL

All Distribution Board housing, circuit protective devices and


accessories must be from Suruhanjaya Tenaga & SIRIM latest
approved type

C 60A TPN DB (Wall Mounted Metalclad Type with Full Front Cover) Set 1
c/w Switch Fuse, RCCB, MCB's, Surge Protective Device (SPD),
etc) - Ground Floor

D 60A TPN DB (Wall Mounted Metalclad Type with Full Front Cover Set 1
c/w Switch Fuse, RCCB, MCB's, Surge Protective Device (SPD),
etc) - First Floor

F 60A TPN TNB Meter Panel c/w wiring , Cut-out & Neutral Link and Set 2
accessories, etc. (Wall Mounted Metalclad & Hard Fiber Base Type)
at TNB Meter Compartment

G 650mm (L) x 650mm (W) x 650mm (H) of Reinforce Concrete (RC) Lot 1
Electrical Service Manholes complete with Heavy Duty RC Flushed
Cover, Hole Opening for 4 nos of 150mm Dia GI Ducting c/w 4 nos
150mm Dia. GI Ducting (Class C) extended beyond perimeter drain
and apron slab

H 1 no. x 150mm Dia. HDPE Double Wall Corrugated Underground Lot 1


Ducting from bottom TNB Meter Panel and extended beyond drain
and after infront of road curb.

B6.3/2 TO COLLECTION