BLUEPRINT-PLUMBING
BLUEPRINT-PLUMBING
CB GT
3600 LEGEND OF SYMBOLS:
LAV
FD
CB DS WATER DISTRIBUTION SYSTEM
DS FD
SINK
WC 150 1200 150 900 150 900 150
FAUCET
PLUMBING FIXTURES M
CO
CO
1200
DIGESTIVE LEACHING OUTLET
FD
CO
DS CHAMBER CHAMBER CHAMBER
CB CB DS 100mm THK. R.C. SLAB w/1
0mmØ LONGITUDINAL
BARS spaced @ .30 M. O.C.
CO
PLAN
MH MH MH COUNTER SUNK FLOOR
FD FD NGL NGL CLEAN OUT "METMA"
100
DS
BRAND MODEL M-349-27
WC
SOIL PIPE (SP)
AIR SPACE AIR SPACE AIR SPACE
DS DS FD
CB CB
LAV
4"ØPVC. PIPE TAP TO 4"ØPVC. PIPE TAP TO
HB
SH
EXISTING PUBLIC SEWER EXISTING PUBLIC SEWER PLAN
1500
LINE. LINE.
M
1850
DIGESTIVE LEACHING OUTLET COUNTER SUNK FLOOR
CLEAN OUT "METMA"
GV
100150
GROUND FLOOR SECOND FLOOR
PLUMBING LAY-OUT PLAN PLUMBING LAY-OUT PLAN
101
CERTIFICATION SCALE : 1:50M SCALE : 1:50M
SECTION
DS WC
FD
REDUCER BUSHING L=25x25x6 FRAME
ANGULAR EDGING
GENETRAL NOTES:
FD DS UNION PATENTE
SH 1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE
LA
20Ø WATER METER PROVISIONS OF THE NATIONAL PLUMBING CODE, THE NATIONAL BUILDING CODE &
V THE RULES & REGULATIONS OF MUNICIPALITY OF BAUAN.
UNION PATENTE
2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATION.
FD 20Ø GATE VALVE THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN.
FD
DS LIFTING HANDLE PLAN 3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATIONS
90Ø ELBOW (RETRACTABLE) L-25x25x6 FRAME REQUIRED FOR PROPER EXECUTION OF OTHER TRADE SHALL BE WITH PRIOR
CL APPROVAL OF THE ARCHITECT OR ENGINEER.
15Ø HOSE BIBB R.C. COVER FIN. FLR. LINE 4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH
FD
FFL. AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS VERIFIED
BY THE CONTRACTOR.
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS OTHERWISE
CB
SPECIFIED.
20Ø/25Ø 20Ø/25Ø 6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE
GT
CWL CWL MANUFACTURER'S INSTRUCTIONS.
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, COORDINATE THE
SIN
K
WRAPPED W/ BURLAP WORKS WITH THE SEWER LINE EFFLUENT DISPOSAL POINT AND WATER LINE SERVICE
& COATED W/ COALTAR CONNECTING POINT, UNLESS OTHERWISE SPECIFIED.
CB IF BURRIED 8. ALL PIPE SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS UNLESS
UNDERGROUND FOR OTHERWISE SPECIFIED.
CORROSSION PROTECTION 100mm. THK CHB WALL W/
10Ø HOR. & VERT. BARS MATERIALS SPECIFICATIONS:
@ 200mm. O.C.
CWL FR. MAIN CWL TO COLD WATER LINE SHALL BE POLYVINYL CHLORIDE (PVC) PIPE CLASS 150
CB LA STREET WATER LINE FIXTURES "NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.
DS V FD
FA
UC WC
4"Ø
ET
DS SEWER LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000
E
LINXIS PV
E. TINC.
G PIP
PU E T
CB
DETAIL OF WATER METER CONC. DRAIN PIPE
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.
FITTINGS SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564.
BL AP
IC T
(VERIFY DIAMETER) VENT PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 600,
SE O
WE "NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.
R FITTINGS SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564.
WA3"ØP DS 4-10Ø BOTTOM
TE VC. CB
RS P
BARS BOTHWAYS DOWNSPOUT SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 600
UP IPE
M HB
PLY TA "NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.
LINP TO
GV
E. FITTINGS SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564.
FROM THE OFFICE OF. SEAL REG NO.: 0014232 PROJECT TITLE : APPROVED AS TO PLAN : SHEET CONTENTS DRAFTED : ABDIEZ LA-DES SHEET NO.
VALIDITY: 05/05/2025 CHECKED : P
LADY MAE P. BRIGOLI PTR NO.: 3671622 PROPOSED TROCHU RESIDENCE PAULINE TROCHU CAD BY :ABDIEZ ABDIEZ
MASTER PLUMBER DATE : 02/07/2024 DATE : 1
ADDRESS: BOJO, ALOGUINSAN, CEBU TIN. : 736-735-413-000 LOCATION : MOALBOAL, CEBU ADDRESS : MOALBOAL, CEBU FILE :