CONTROLLERS
Main features
• Universal input configurable from faceplate
• Accuracy better than 0.2% f.s. under
nominal conditions
• Control output: relay, logic, Triac or
continuous
Main applications • Hot/cold function with selection of cooling
• Extrusion lines fluid
• Injection presses for plastics • 3 alarms with completely configurable
• Heat punches function
• Analog retransmission output
• Presses for rubber
• Up to 2 isolated digital inputs with
• Packaging machines configurable function
• Packing machines • Isolated digital input with configurable
• Polymerization and synthetic function
fiber plants • Auxiliary input for CT (TA) (50mAac)
• Food processing pants • Heater break or probe short-circuit alarm
• Die-casting plants • Self-tuning, Auto-tuning, Soft-start, bumpless
• Cooling plants Man/Auto function
• Double set, set ramp, timed output function
• Climatic cells and test benches
• Optically isolated RS485 serial line.
• Dryers for ceramics and Protocol: GEFRAN MODBUS RTU
construction parts • Self-diagnosis
• Ovens • Rapid configuration from PC with Winstrum
• Painting plants packet
PROFILE An analog output in voltage or in current For even simpler configuration, you can
Microprocessor controllers, 48x96 is also available. use a PC programming kit consisting of a
(1/8DIN) format for 1200 and 96x96 The functions of each output are freely cable and a guided program for Windows
(1/4DIN) format for 1300, built with SMT configurable from the faceplate. environment (see Technical Data code
technology. Complete operator interface, In addition to the control and alarm WINSTRUM).
protected by Lexan membrane to outputs, you can also have outputs that
guarantee an IP65 faceplate protection repeat the state of the digital or TECHNICAL DATA
level. Composed of 4 keys, double 4-digit retransmission input by process variable,
green LED display, 4 red signal LEDs for setpoint, deviation, alarm trip points and INPUTS
the 4 relay/logic outputs and 3 additional values acquired via serial line. An Accuracy 0,2% f.s. ±1digit.
LEDs with programmable function to additional output (24VDC, 30mA max.) is Acquisition of the input signal 120msec.
signal the instrument’s various function available to power outside transmitters.
states. The serial communication option can be TC - Thermocouples
The main input for the variable to be in Current Loop or RS485, with MODBUS J 0...1000°C / 32...1832°F
controlled is universal, and allows RTU protocol and maximum speed of K 0...1300°C / 32...2372°F
connection of a wide variety of signals: 19200 baud (485). R 0...1750°C / 32...3182°F
thermocouples, resistance thermometers, The instrument’s entire programming S 0...1750°C / 32...3182°F
thermistors, normalized linear inputs, all procedure is made easier by grouping the T -200...400°C / -328...752°F
with possibility of custom linearization set parameters in function blocks (CFG for B 44...1800°C / 111...3272°F
from the faceplate. control parameters, Inp for inputs, Out for E -100...750°C / -148...1382°F
Input type is selected entirely from the outputs, etc.). N 0...1300°C / 32...2372°F
faceplate and requires no external The instrument can also select the custom -1999...9999
adapter shunts/dividers. parameters to be displayed based on its Using the custom solution, tables are
A second auxiliary analog input from hardware configuration, which available for the following thermocouples:
current transformer is available. You can automatically hides irrelevant parameters. L-GOST 0...600°C / 32...1112°F
select one of the two presettable The instrument is supplied with an U -200...400°C / -328...752°F
setpoints, select Manual-Automatic mode, “EASY” configuration calling for just a few G 0...2300°C / 32...4172°F
reset the alarm memory, or enable the parameters (only those pertaining to the D 0...2300°C / 32...4172°F
hold function by means of the digital model ordered and essential to the C 0...2300°C / 32...4172°F
input. controller’s operation). (NI-Ni18Mo) 0...1100°C / 32...2012°F
The instrument provides up to 4 outputs: In this way, you just have to set the RTD 3-wires
relay (5A, 250VAC/30VDC cosϕ = 1) or setpoint and the alarm, then launch self- PT100 -200...850°C / -328...1562°F
logic (24V ± 10% (10Vmin a 20mA). tuning with the specific button. JPT100 -200...600°C / -328...1112°F
PTC The outputs are freely assignable to control AMBIENT CONDITION
990Ω, 25°C -55...120°C / -67...248°F and alarm functions (in "OR" or "AND").
NTC They can be slaved to a faceplate key or to Working temperature range: 0...50°C
1KΩ, 25°C -10...70°C / 14...158°F the auxiliary digital input. Storage temperature range: -20...70°C
Humidity: 20...85%Ur non condensing
DC - Linear Relay
With scale settable in limits: (order code R) CONTROL
-1999...9999 With rating: 5A/250Vac/30Vdc, cosϕ=1 On/Off, P, PD, PID in both heating and
0...60mV / 12...60mV cooling, with parameters settable from
Logic keyboard..
0...10V / 2...10V
(order code D) Cooling setpoint relative to heating
0...5V / 1...5V
24Vdc, Rout=100Ω (10V/20mA) setpoint.
0...1V / 0,2...1V
0...20mA / 4...20mA • Manual reset -999...999 digits
Triac (order code T)
Imput impedance: • Reset power -100.0...100.0%
24...240Vac ± 10%, 50/60Hz, 1A max.
Ri > 1MΩ per 60mV,1V • Cycle time 0...200sec
I2t = 128A2sec.
• Soft-start 0.0...500.0 min
Ri > 10KΩ per 5V, 10V Leakage current 1.5mA max a 200Vac.
For each action:
Ri = 50Ω per 20mA
Custom linearisation with 32 segment. Continuous (order code C) • Proportional band 0.0...999.9% f.s.
0...10V, 0/4...20mA, on 500Ω max • Integral time 0.0...99.99 min
Auxiliary input only for heat/cool control output. • Derivative time 0.0...99.99 min
(IN CT) • Maximum power limit 0.0...100.0%
For current transformer Retransmission
50mAac, 50/60Hz, Ri=10Ω (order code W) ALARMS
0...10V, 0/4...20mA, on 500Ω resolution • 3 alarm limits settable in absolute,
Digital input 12bit, useful for retransmission of the deviation, symmetrical deviation value
(IN1/IN2) variable. compared to set-point with direct or
PNP: Ri = 4,7KΩ (24V, 5mA) insulation reverse function.
1500V Serial line • Alarm limit settable along entire
NPN: voltage-free contact. Optoisolated 2/4 wires, RS422/485 (1200, selected scale.
Function configurable among man/auto 2400, 4800, 9600, 19200 baud) interface • Alarm masking with exclusion at
selection, local/remote (setpoint from Prot.: MODBUS RTU power-up, with memory, with trip delay.
serial line, setpoint1/setpoint2); • LBA alarm for adjustment control
POWER SUPPLY
Set/reset outputs, start/stop tuning • Trip hysteresis settable for each alarm
functions, software off/on, reset alarm
Standard:
• Alarm assigned to ammeter input with
memory, hold. 100...240Vac/dc ± 10% max 18VA
different function modes.
On request:
OUTPUTS 11...27Vac/dc ± 10% max 11VA
4 configurable outputs: 50/60Hz. Protection by internal fuse not WEIGHT
• OUT1 relay (switching contact only with serviceable by the user 320g (1200)
OUT2 relay) 400g (1300)
• OUT2 available in relay, logic or triac POWER SUPPLYTRANSMITTER
• OUT3 available in relay, logic, 24V ±10% not stabilized, 30mA
continuous or analog retransmission Short circuit protection
• OUT4 relay or logic.
FACEPLATE DESCRIPTION
G B
F C
1200 1300
96 115
48 70
108 96
108 96
115 115
92 92
44,5 92
100 100
10 10
CONNECTION DIAGRAM
12 11
PWR
OUT3
100-240 Vac/dc
11-27 Vac/dc
13 10
NC
14 9
OUT4
(Current transformer)
OUT 1
15 8
C C only if OUT2 = T
IN CT
COM. NO NO
16 7
IN2
IN1
OUT 2
17 6
18 5
19 4
RX
GND
(mA)
SERIAL LINE
20 3
VT
B data
21 2
TX
A data
22 1
RS485 RS485 Pt100 V/I
TC
(2 wire) (4 wire) (3 wire)
POWER SUPPLY
MODEL 0 11...27Vac/dc
1200 1 100...240Vac/dc
1300
DIGITAL COMMUNICATION
OUTPUT 1
0 None
Relay R
2 RS485
OUTPUT 2
Relay R DIGITAL IN1, IN2 / AUXILIARYCT INPUTS
Logic D 00 None
Triac (1A) T 01 IN1 + IN2 (NPN / PNP)
02 IN1 + IN CT (50mAac)
OUTPUT 3
None 0
Relay R
Logic D
Continua 0...10V (0/4...20mA) C
Analog 0/4...20mA (0...10V) W
OUTPUT 4
None 0
Relay R
Logic D
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
The instrument conforms to the European Directives 2004/108/CE and 2006/95/CE with reference to the generic standards:
EN 61000-6-2 (immunity in industrial environment) - EN 61000-6-3 (emission in residential environment) - EN 61010-1 (safety)