SCREW CLAMP TERMINAL BLOCKS

FUSE CF4U

TERMINAL
BLOCKS

These Terminal Blocks are used in electrical Width (Thickness) x Length 8 x 57 mm


and control systems which require fuse
Height with DIN 35 x 7.5 / 35 x 15 / 32 x 15 mm Rail 50.3 mm / 57.6 mm / 56.5 mm
protection. The CSFL series accepts industry
standard Ø5 x 20 mm and Ø5 x 25 mm glass Connection Possibility as per IEC UL - CSA
cartridge fuses. Fuse blocks are supplied Stranded / Flexible 2
With 1 Conductor 0.25 - 4.0 mm 22 - 10 AWG
with a 6.3 A fast blow fuse (unless specified). Solid 0.25 - 6.0 mm2 22 - 8 AWG
per clamp
These Terminal Blocks are used in electrical and with Ferrule / Lug 0.25 - 4.0 mm2 22 - 10 AWG
control systems which require fuse protection. With 2 same size Stranded / Flexible 0.25 - 2.5 mm2 22 - 12 AWG
Conductors per clamp with TWIN Ferrule / Lug 0.25 - 2.5 mm2 22 - 12 AWG
The CF series accepts industry standard Ø5 x 20
mm and Ø5 x 25 mm glass cartridge fuses. These Wire Stripping Length 9.5 mm
blocks are completely closed and do not need a
Ratings As Per IEC60947-7-3 UL-1059 CSA22.2-158
separate end plate. Fuse blocks are supplied
with a 6.3 A fast blow fuse (unless specified). Voltage 1000 V 600 V 600 V

CF4UL is used for offline indication in case of a Current 6.3 A 10 A 10 A


fuse blow out. Torque 0.5 Nm 7 lb-in 7 lb-in
These blocks can be used with AC & DC voltages.
Approvals

Insulation Material / Comparative Tracking Index Polyamide 66 / 1

Rated Impulse Voltage / Pollution Degree 5 KV / 3


Fuse Size Ø5 x 20, Ø5 x 25 mm

Fuse Indication
Type / Cat. No. Standard Pack

Terminal Block With Fuse


Without Fuse CF4U 100
For 6 - 60 V AC/DC
For 110 - 240 V AC/DC
For 24 V AC/DC
For 48 V AC/DC
For 110 V AC/DC
For 220 V AC/DC
For 440 V AC
End Plate

Partition Plate
CA701 50 m
Mounting Rail (Refer Pg. 136 for details) CA701-15 50 m
CA501 50 m
CA702 50
End Clamp (Refer Pg. 137 for details)
CA802 50
2 pole CA711/2 Imax.: 32 A 100
Insulated External 3 pole CA711/3 32 A 50
Shorting Links 4 pole CA711/4 32 A 50
10 pole CA711/10 32 A 20
On Terminal CA509/K8 100
Marking Tags
On Fuse Carrier CA509/K8 100
Screw Driver SCS0.6/3.5 Blade size: 0.6 x 3.5 mm 10
w w w. c o n n e c t w e l l . c o m

CF4UL

Width (Thickness) x Length 8 x 57 mm


Height with DIN 35 x 7.5 / 35 x 15 / 32 x 15 mm Rail 50.3 mm / 57.6 mm / 56.5 mm
Connection Possibility as per IEC UL - CSA
2
Stranded / Flexible 0.25 - 4.0 mm 22 - 10 AWG
With 1 Conductor
per clamp
Solid 0.25 - 6.0 mm2 22 - 8 AWG
with Ferrule / Lug 0.25 - 4.0 mm2 22 - 10 AWG
With 2 same size Stranded / Flexible 0.25 - 2.5 mm2 22 - 12 AWG
Conductors per clamp with TWIN Ferrule / Lug 0.25 - 2.5 mm2 22 - 12 AWG
Wire Stripping Length 9.5 mm

Ratings As Per IEC60947-7-3 UL-1059 CSA22.2-158


Voltage 1000 V 600 V 600 V

Current 6.3 A 10 A 6.3 A


Torque 0.5 Nm 7 lb-in 7 lb-in

Approvals

Insulation Material / Comparative Tracking Index Polyamide 66 / 1

Rated Impulse Voltage / Pollution Degree 5 KV / 3


Fuse Size Ø5 x 20, Ø5 x 25 mm

Fuse Indication 6 - 60 V AC/DC, 110 - 240 V AC/DC


Type / Cat. No. Standard Pack

Terminal Block With Fuse


Without Fuse
For 6 - 60 V AC/DC CF4UL6-60V 50
For 110 - 240 V AC/DC CF4UL110-240V 50
For 24 V AC/DC
For 48 V AC/DC
For 110 V AC/DC
For 220 V AC/DC
For 440 V AC
End Plate

Partition Plate
CA701 50 m
Mounting Rail (Refer Pg. 136 for details) CA701-15 50 m
CA501 50 m
CA702 50
End Clamp (Refer Pg. 137 for details)
CA802 50
2 pole CA711/2 Imax.: 32 A 100
Insulated External 3 pole CA711/3 32 A 50
Shorting Links 4 pole CA711/4 32 A 50
10 pole CA711/10 32 A 20
On Terminal CA509/K8 100
Marking Tags
On Fuse Carrier CA509/K8 100
Screw Driver SCS0.6/3.5 Blade size: 0.6 x 3.5 mm 10

27KÙ

LED Circuit for offline


27KÙ indication in CF4UL6-60V

200KÙ

LED Circuit for offline


200KÙ indication in CF4UL110-240V