P- 083 LV Capacitor JKF8

2. Type designation
JK F 8- , (50Hz or 60Hz)

Rated voltage:380V,440V,220V,240V

Output loop specification:6,12

Low-Voltage
Reactive Power Compensation Controller Series

3. Features

3.1 With combined control on reactive power and power factor, a


reliable input can be ensured under low load, and surge switching
can be prevented.

3.2 Real-time display of the network status,including parameters such


as power factor,voltage, current, active power, and reactive power,
etc.

3.3 The polarity of the sampling signal can be automatically


identified. Therefore, there is no need to worry about wrong
connections with reversed polarity.

JKF8 Intelligent Low-Voltage 3.4 In case the voltage of the electrical power network is lower
Reactive Power than 300 V, or exceeds the preset over-voltage protection value,the
connected capacitor banks will be automatically and rapidly(5 sec.)
Compensation Controller disconnected in steps, and the voltage value will be displayed.

3.5 In case the signal from the secondary coil of the current
1. General transformer is smaller than 150 m A, the controller will prevent
any more capacitor from being connected, in the mean time,
JKF8 Intelligent Low-Voltage
automatically and rapidly (5 sec.)disconnect the connected capacitor
Reactive Power Compensation Controller (hereinafter referred to as
banks step-wise.
'controller' ) is a dedicated controller which can make compensations
for the reactive power of low voltage distribution system.
3.6 Switching (opening/closing control of the contactor) prevention
time for the same group of capacitors is 3 minutes(capacitor
discharge duration)

3.7 The controller is with cyclic automated-self-test function, which


facilitates the factory acceptance test for a capacitor panel.

4. Operating conditions

4.1 Ambient temperature: -10℃ ~+40℃

4.2 Relative humidity: ≤50%, when 40℃ , ≤90% when 20℃

4.3 Altitude: ≤2000 m

4.4 Operation environment: free of hazardous gas and/or vapor,


conductive or explosive dust, or rigorous mechanical vibration.

4.5 Operation voltage: Un±20%


JKF8 LV Capacitor P- 084

5. Technical data
Parameters Technical Specifications

Sampling voltage 400VAC±10%(Can be customized: 220VAC, 440VAC)

Sampling current 150mA~5 A

Rated frequency 50/60Hz±5%

Low-current capacitor
connection prevention ≤150 mA

Range of transformation ratio for sampling current transformer: 5~800,


Current transformation ratio Preset value of the ratio (preset value in factory: 60, which means 300/5)

Time lag 5~120 seconds (preset value in factory: 30 seconds)

Full automation mode (displayed code F-0: 1): no need to set the capacitor connection threshold
or the capacitor disconnection threshold.
Preset mode Manual setup mode(displayed code F-0: 0): need to set the capacitor connection threshold and
the capacitor disconnection threshold manually.

Capacitor connection Full automation mode: capacitor banks in the smallest step
threshold Manual mode: preset value for reactive power: 1~120 kvar (preset value in factory: 10kvar)

Capacitor disconnection threshold Power factor, 0.85 ~ -0.95 continuously adjustable (preset value in factory: 1.00)

Over-voltage threshold 400 V~456 V (preset value in factory: 430 V), 230V~270V (preset value in factory: 250 V)

JKF8-6 (loop number can be set between 1 and 6),


Loop number JKF8-12(loop number can be set between 1 and 12)

Operation mode Automated cyclic opening/closing control & manual operation

Max. power consumption 15 W

Output contact point capacity 5A/230V(or 3A/400V)


Weight Approximately1.5 Kg

6. Wiring diagram

High voltage side

10 ls1

9 ls2 Power transformer


JKF8 Rear View
Total current transformer

8
A B C N
7 Us1

6 Us2

5 H
Low voltatge side

3 COM L

2 12 FU1 FU2 FU3

1 11

5A 1A 1A

P P

J1 J12
To load control panel

Note: If the coil voltage of the contactor is 230V,


point P is connected to Phase N.
If the coil voltage of the contactor is 400V,
point P is connected to Phase B or C.
P- 085 LV Capacitor JKF8

6.1 Connection terminal US1 and US2 are to be connected to the sampling voltage. AC 400 V or AC 220V shall be connected.

6.2 Terminal IS1 and IS2 are to be connected to the sampling current, which shall be sampled from the transformed current generated by the current
transformer for the load, and which shall not be in-phase with US1 and US2(if A is for current, then B and C are for voltage).

6.3 Terminal COM is the common shared terminal to be connected to number 1 to 12 relays in the output lines of the controller, and each of the
terminals 1~12 is to be connected to the output control line to control the respective contactor in the respective compensation loop of the capacitor
panel.

6.4 If the coil voltage of the contactor J is 230 V, then Point P is connected to Phase N. If the coil voltage of the contactor Jis 400 V, then Point P is
connected to Phase C(as long as it is not in-phase with terminal COM).

6.5 FU1~3 are to be connected to fusers which are supplied by the user.

7. Description of parameters
7.1 Description of dynamic parameters

Code Signification Unit Description

If the measured value is out of the display range,


I Current A
the approximate value will be displayed,e.g,1260 A is displayed as E13

U Voltage V Display the measured voltage value

If the measured value is out of the display range, the approximate value
Q Reactive power kVar
will be displayed,e.g,1360 Kvar is displayed as E14.

If the measured value is out of the display range, the approximate value
P Active power kW
will be displayed,e.g,1360 kW is displayed as E14.

7.2 Description of preset parameters (menu description)

Range of Factory Change


Code Description Remark
Settings Settings Step

1 full automation
F-0 Preset mode 1or0 1 -
0 manual setup

This parameter is invalid


F-1 Capacitor connection threshold 1~120 kVar 10 kVar 1 kVar
under the full automation mode

F-2 Target power factor 0.85~-0.95 1.00 0.01 "-"stands for system capacity

F-3 Switching time lag 5~120 sec. 30 sec. 1 sec.

F-4 Over-voltage protection 400V~456V 430V 2V Voltage difference:8~10V

F-5 Number of control loop 1~6or 1~12 6 or 12 1 Two types of specifications

Transformation ratio of the


F-6 5~800 60 5 (300:5)
sampling current transformer

8. Mounting dimensions (mm)

120mm
113mm±0.5mm
120mm

130mm 113mm±0.5mm
Boring dimension

9. Ordering information
On ordering, please clarify rated voltage, number of phase, frequency, etc of the products;
and associated conditions at the mounting place.