v6.3.1c_ReleaseNotes_v1.0
v6.3.1c_ReleaseNotes_v1.0
1c
Release Notes v1.0
Document History
Document Title Summary of Changes Publication Date
Brocade Fabric OS v6.3.1c Release Notes v1.0 Initial release May 19, 2010
© 2010 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronView, NetIron, SAN Health, ServerIron,
and TurboIron are registered trademarks, and Brocade Assurance, DCFM, Extraordinary Networks, and
Brocade NET Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or
in other countries. Other brands, products, or service names mentioned are or may be trademarks or
service marks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or
implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade.
Brocade reserves the right to make changes to this document at any time, without notice, and assumes no
responsibility for its use. This informational document describes features that may not be currently
available. Contact a Brocade sales office for information on feature and product availability. Export of
technical data contained in this document may require an export license from the United States
government.
Notice: The product described by this document may contain “open source” software covered by the GNU
General Public License or other open source license agreements. To find-out which open source software is
included in Brocade products, view the licensing terms applicable to the open source software, and obtain
a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Export of technical data contained in this document may require an export license from the United States
Government
New Enhancements
FOS v6.3.1 supports the following new functionality:
- IPSec support on the Brocade 7800
- VLAN tagging (802.1p) support on 7800/FX8-24 FCIP links
- 10 to 1G tunnel/circuit connectivity configuration on FX8-24
o Allows connection between 10GbE ports on an FX8-24 and 1GbE ports on a 7800 or FX8-24
through an Ethernet switch
- FIP (FCoE Initialization Protocol) v1.0 (FC-BB5v2.0 - was included in FOS v6.3.0b and later)
- Port Beaconing (also supported in FOS v6.2.1)
- Automatic assignment of slot-based licenses
- Access Gateway support on the Brocade 8000 (if using DCFM, v10.4 or later is required)
• Advanced FICON Acceleration – This new licensed feature uses specialized data management
techniques and automated intelligence to accelerate FICON tape read and write and IBM Global Mirror
data replication operations over distance, while maintaining the integrity of command and
acknowledgement sequences. This license is available on the 7800 and the DCX/DCX-4S for the FX8-
24 on an individual slot basis.
Some models offer bundles that include 2 or more optionally licensed features. These bundles are defined for
each unique product, and are outside the scope of this release note document.
Supported
Supported Switches
Fabric OS v6.3.1 supports the Brocade 300, 5410/5480/5424/5450/5460/5470/NC-5480, 4100, 4900,
5000, 5100, 5300, VA-40FC, 7500/7500E, 7600, 48000, Brocade Encryption Switch (BES), DCX/DCX-4S,
8000, and the new 7800. All supported products are qualified for Native Connectivity in interopmodes 2 and 3
for deployment in M-EOS fabrics with the exception of the Brocade 4100 and 8000.
Access Gateway mode is also supported by Fabric OS v6.3.1, and is supported on the following switches: the
Brocade 300, 5100, VA-40FC, 8000*, 5480, 5450, 5460, 5470, NC-5480 and M5424.
* If using DCFM to manage a fabric with a Brocade 8000 in Access Gateway mode, version 10.4 or later is
required
Note that FOS v6.3 does NOT support the following platforms and cannot be loaded on them, though these
switches may participate in the same fabric as other switches using FOS v6.3:
• Brocade 200E
• All 4G embedded switches, including the 4012, 4016, 4018, 4020, 4024, 4424
Standards Compliance
This software conforms to the Fibre Channel Standards in a manner consistent with accepted
engineering practices and procedures. In certain cases, Brocade might add proprietary supplemental
functions to those specified in the standards. For a list of FC standards conformance, visit the
following Brocade Web site: http://www.brocade.com/sanstandards
The Brocade 8000 and FCOE10-24 blade conform to the following Ethernet standards:
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree
• IEEE 802.1w Rapid reconfiguration of Spanning Tree Protocol
• IEEE 802.3ad Link Aggregation with LACP
• IEEE 802.3ae 10G Ethernet
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1p Class of Service Prioritization and Tagging
• IEEE 802.1v VLAN Classification by Protocol and Port
• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
• IEEE 802.3x Flow Control (Pause Frames)
The following draft versions of the Converged Enhanced Ethernet (CEE) and Fibre Channel over Ethernet (FCoE)
Standards are also supported on the Brocade 8000 and FCOE10-24 blade:
• IEEE 802.1Qbb Priority-based Flow Control
• IEEE 802.1Qaz Enhanced Transmission Selection
• IEEE 802.1 DCB Capability Exchange Protocol (Proposed under the DCB Task Group of
IEEE 802.1 Working Group)
• FC-BB-5 FCoE (Rev 2.0)
Technical Support
Contact your switch supplier for hardware, firmware, and software support, including product repairs and part
ordering. To expedite your call, have the following information immediately available:
1. General Information
• Technical Support contract number, if applicable
• Switch model
• Switch operating system version
• Error numbers and messages received
• supportSave command output
• Detailed description of the problem, including the switch or fabric behavior immediately following
the problem, and specific questions
• Description of any troubleshooting steps already performed and the results
• Serial console and Telnet session logs
• Syslog message logs
FT00X0054E9
TSB Summary
None There are no current TSBs outstanding for this FOS release.
TSB Summary
2010-
2010-075-
075-A When upgrading a DCX, DCX-4S or Brocade 5300 from Fabric OS v6.2.2a or lower to FOS
(Defect v6.3.1 or 6.3.0c or lower, the Compact Flash (CF) may report an access error. This will cause a
270261) reboot of the affected CP within the DCX/DCX-4S or Brocade 5300 to fail.
After performing a non-disruptive firmware upgrade from Fabric OS v6.2.x to Fabric OS v6.3.0
2010-
2010-076-
076-A through v6.3.0c or v6.3.1, the State Change Registration (SCR) value is not preserved in the
(Defect Name Server database. After this occurs, the Name Server will not transmit Registered State
284472) Change Notifications (RSCN) to the devices on those ports. If a device does not receive an
RSCN, it will not know when there is a change to the zoning configuration or device availability.
Most products supported by Fabric OS v6.2.X or v6.1.2_CEEx can be upgraded to Fabric OS v6.3. The
following is a list of products that can be upgraded to Fabric OS v6.3:
• 5424/5410/5480, 4100, 4900, 5000, 300, 5100, 5300, 7500/7500E, 7600, 8000,
48000, BES, DCX-4S and DCX.
Switches using Integrated Routing and operating with FOS v6.2.2x may not be upgraded directly to
FOS 6.3.0/v6.3.0a/v6.3.0b. Units operating with IR and FOS v6.2.2x should be upgraded to FOS
v6.3.0c, v6.3.1 or later firmware or first downgraded to a release prior to v6.2.2.
FOS does not support concurrent FC Routing (EX_Ports) and TopTalkers features.
If there are multiple node EGs (encryption groups) in a fabric, please complete firmwaredownload on
one node at a time before downloading on another node.
The Brocade 8000 does not support non-disruptive hot code loads (HCL). Upgrading the Brocade
8000 from FOS v6.1.2_cee1 to FOS v6.3 or from FOS 6.3 to a later FOS version will be disruptive to
the IO through the switch.
A code load of DCX or DCX-4s with one or more FCOE10-24 blades from FOS 6.3 to another version
will disrupt traffic through the blade.
When upgrading a Brocade 8000 from FOS v6.1.2_CEE or v6.1.2_CEE1 to v6.3, verify that the unit
has both the FCoE and FC POD licenses installed. Units missing these licenses that are upgraded to
FOS v6.3 will lose functionality following a restart or disabling of ports. Note that when the FC POD
license is installed on a unit with FOS v6.1.2, the licenseShow output will indicate that the license is
“not applicable on this platform.” This message can be ignored and will not appear once the unit has
been upgraded to v6.3.
If a switch with FOS v6.2 in FIPS (Federal Information Processing Standards) mode with only LDAP
authentication support is upgraded to v6.3, login will fail. A switch with v6.2 in FIPS mode must have
both LDAP and local authentication configured before upgrading to v6.3. Once the switch is fully
operational, the user can login to the switch and import the certificate again. If the switch is not in
FIPS mode, users can login to the switch with LDAP after upgrading to v6.3 and then import the
certificate.
Important
Important Notes
This section contains information that you should consider before you use this Fabric OS
release.
DCFM Compatibility
FOS v6.3.1 is compatible with Brocade’s Data Center Fabric Manager (DCFM) v10.3.x management
software. DCFM is a comprehensive SAN management application that enables end-to-end
management of Brocade Data Center Fabrics. It is the next-generation successor product to existing
Brocade management products, including Brocade Fabric Manager (FM) and Brocade Enterprise
Fabric Connectivity Manager (EFCM).
Existing EFCM v9.6.x/9.7.x and FM v5.4/5.5 customers are provided an easy migration path to DCFM
Enterprise.
DCFM Management Considerations
Considerations
• When managing a Brocade 8000 in Access Gateway Mode, DCFM 10.4.0 or later is required. Use
of earlier DCFM releases will prevent management of zoning on the fabric.
• DCFM v10.3.x and earlier cannot manage FOS switches or fabrics using Administrative Domains
(ADs). Environments using ADs must use DCFM v10.4 or later or use the CLI or WebTools for
management.
WebTools Compatibility
• FOS v6.3 is supported with JRE 1.6.0 Update 13.
• If the JRE v1.6.0 version is not at Update 13, the DCFM server / client and B-model Element
Manager (Web Tools) Crashes on launch
• WebTools Tunnel and TCP graphs only support Tooltips for the first enabled TCP connection graph.
Fabric OS Compatibility
The following table lists the earliest versions of Brocade software supported in this release, that is, the
earliest supported software versions that interoperate. Brocade recommends using the latest
software versions to get the greatest benefit from the SAN.
When using the Virtual Fabrics feature, it is highly recommended that all switches participating in a
fabric with a logical switch use the latest firmware available for those switches. All switches must be
operating at minimum firmware levels noted in the FOS Interoperability table below.
When using any of Brocade’s encryption platforms (Brocade Encryption Switch or Brocade FS8-18
blade in a DCX or DCX-4S) it is required that switches attached to hosts and targets or those that are
part of the encryption flow be operating with minimum specified levels:
• 2Gb/4Gb platforms must operate with FOS v5.3.1b or later
Table Notes:
1All zoning and fabric operations performed in a fabric with products running older versions of FOS should
be done via interfaces to products running the latest version of FOS. This is particularly important for
Brocade 3XXX series switches that do not support zoning configuration for newer products.
Fabric OS v6.3.1 software is fully qualified and supports the blades for the DCX/DCX-4S noted in the following
table:
DCX/DCX
DCX/DCX-
/DCX-4S Blade Support Matrix
*Note: the iSCSI FC4-16IP blade is not qualified for the DCX/DCX-4S.
FOS Feature Compatibility in Native Connectivity Modes
Some FOS features are not fully supported when operating in the native connectivity modes for deployment
with M-EOS based products. All Brocade models that are supported by Fabric OS v6.3.1 support both
interopmodes 2 and 3 with the exception of the Brocade 4100 and 8000 and DCX/DCX-4S with one or more
FCOE10-24 blades.
The following table specifies the support of various FOS features when operating in either interopmode 2
(McDATA Fabric Mode) or interopmode 3 (Open Fabric Mode) with Fabric OS v6.3.
Scalability
All scalability limits are subject to change. Limits may be increased once further testing has been completed,
even after the release of Fabric OS. For current scalability limits for Fabric OS, refer to the Brocade Scalability
Guidelines document, available under the Technology and Architecture Resources section at
http://www.brocade.com/compatibility
• Brocade recommends that Converged Mode be enabled on all interfaces connected to CNAs.
• When operating in Converged Mode, tagged traffic on the native VLAN of the switch interface is
processed normally. The host should be configured not to send VLAN tagged traffic on the switch’s
native VLAN.
• The Converged Network Adapter (CNA) may lose connectivity to the Brocade 8000/FCOE10-24 if the
CNA interface is toggled repeatedly over time. This issue is related to the CNA and rebooting the CNA
restores connectivity.
• Although the Brocade 8000 and FCOE10-24 support the configuration of multiple CEE maps, it is
recommended to use only one CEE map on all interfaces connected to CNAs. Additionally, CEE maps
are not recommended for use with non-FCoE traffic. QoS commands are recommended for interfaces
carrying non-FCoE traffic.
• It is recommended that Spanning Tree Protocol and its variants be disabled on CEE interfaces that are
connected to a server.
• The Fabric Provided MAC Address (FPMA) and the Fibre Channel Identifier (FCID) assigned to a
VN_Port cannot be associated with any single front-end CEE port on which the FLOGI was received.
• LLDP neighbor information may be released before the timer expires when DCBX is enabled on a CEE
interface. This occurs only when the CEE interface state changes from active to any other state.
When the DCBX is not enabled, the neighbor information is not released until the timer expires,
irrespective of the interface state.
• The FCoE Login Group Name should be unique in a fabric wide FCoE Login Management
Configuration. The merge logic is designed to modify the Login Group Name during merge when Login
group names in participating configurations conflict with each other. The current OUI of 00051E is
being used by Brocade, while assigning the WWNs to 8000s, DCXs and DCX4Ss, which would make
only the last 3 bytes as different for any two 8000s, DCXs or DCX4Ss. Considering this assignment
method, the merge logic would rename the login group by including the last 3 bytes of WWN in the
login group name, so that they are unique in the merged configuration.
• For switches having different OUI indices from the 8 assigned to Brocade (for ex: 00051E and
006069), WWNs can differ in more than 3 bytes. In this case, after normal merge and a rename as
per above described logic, login group names can be the same for WWNs differing only in OUIs. The
merge logic would drop one of the Login Groups to satisfy the requirement to keep the Login Group
Name unique in the fabric wide configuration.
• Ethernet switch services must be explicitly enabled using the command “fosconfig –enable ethsw”
before powering on an FCOE10-24 blade. Failure to do so will cause the blade to be faulted (fault 9).
• In order to support non-disruptive firmware upgrades on the DCX/DCX-4S, a new service “ethsw” is
being introduced to enable Ethernet switching on FCOE10-24 in FOS v6.3. LAN switching is disabled
by default in FOS v6.3. The user must explicitly enable Ethernet switch service to prevent FC traffic
interruption using the command “fosconfig –enable ethsw”. Upgrading from FOS v6.x to FOS v6.3 is
non-disruptive. User can enable ethsw after upgrade without FC traffic interruption.
EE Slot: 0
SP state: Online
Current Master KeyID: 43:f1:bd:dc:91:89:f2:f1:6a:a1:48:89:7b:d0:5f:59
Alternate Master KeyID: 3a:a4:5b:86:90:d5:69:26:29:78:f8:3b:f9:b2:9c:b9
HA Cluster Membership: hac39_115
EE Attributes:
Link IP Addr : 10.32.50.36
Link GW IP Addr: 10.32.48.1
Remote EE Reachability :
The Brocade 8000 contains up to 24 internal FCoE ports and eight external Fibre Channel ports. In
Access Gateway mode, the FCoE ports are configured as F_Ports, while the Fibre Channel ports are
configured as N_Ports. The FCoE ports are divided into six groups or trunks consisting of four ports
each. All four ports in a group are mapped to one N_Port. Although you can change the default F_Port
group to N_Port mapping for these groups (refer to “Default port mapping” on page 13), consider the
following when working with these FCoE ports:
• All four FCoE ports in the port group are mapped to the same Fibre Channel N_Port.
• You cannot map individual FCoE ports within the same port group to different Fibre Channel
ports.
• Any Access Gateway operation that involves moving F_Ports will move all FCoE ports in the
group.
• All four FCoE ports in a group will failover or failback to one Fibre Channel N port.
• All four FCoE ports are considered as a unit for rebalancing.
On page 11 under the “Default Port Mapping” section, add the following information for Brocade 8000
default F_Port to N_Port mapping:
Defect ID:
ID DEFECT000269189 Technical Severity:
Severity Medium
Summary:
Summary SERDES tuning values to support BR–804 HBA
Symptom:
Symptom Fine tune SERDES value for BR–804 HBA support. This change only applies to Brocade 5480
platform.
Feature:
Feature Embedded Platform Services Function:
Function Brocade 5480
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.4.0, FOS6.3.1 a, FOS6.3.1 b
Defect ID:
ID DEFECT000269942 Technical Severity:
Severity High
Summary:
Summary On the Brocade 7800 and FX8-24, with emulated tape and tape pipeline, if there is frame drop
on back end, read tape pipeline does not handle the error and causes tape access to hang.
Back end read IO recovery needs enhanced for tape emulation .
Symptom:
Symptom When running emulated tape and tape pipeline on the Brocade 7800 and FX8-24 blade running
FOS 6.3.1 or 6.3.1a, tape access can hang when there is a frame drop on the back end.
Feature:
Feature FCIP Function:
Function Emulation
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000274646 Technical Severity:
Severity High
Summary:
Summary Brocade 8000 installed with FOS v6.3.0 through v6.3.0c, v6.3.1 and v6.3.1a panics doing
firmwaredownload.
Symptom:
Symptom Switch panic reported during firmware download. This only applies to Brocade 8000s factory
installed with FOS v6.3.0 through v6.3.0c, v6.3.1 and v6.3.1a.
Workaround:
Workaround Before upgrading from FOS v6.3.0 through v6.3.0c, v6.3.1 or v6.3.1a, check if /dev/altera is
present in secondary partition. If not present, copy it from primary partition via "cp
/dev/altera /mnt/dev/altera".
Feature:
Feature CEE-Infrastructure Function:
Function Zues Driver
Probability:
Probability High
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000277910 Technical Severity:
Severity High
Summary:
Summary FCR iswitchd skips slot recovery during warm boot with no base switch, causing devices not to
get imported after adding a base switch.
Symptom:
Symptom After having gone through warm recovery with no base switch configured, devices are not getting
imported after adding a base switch to switches with VF and FCR configured. Switch stays in
initializing state in an EtoE FCR fabric. This impacts Brocade DCX, DCX-4S, 5300 and 5100
platforms only.
Workaround:
Workaround Hafailover/hareboot and then toggling the EX_Port to recover or make sure base switch is
configured before hafailover/hareboot.
Feature:
Feature 8G FCR Function:
Function FCR Daemon
Probability:
Probability High
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000278461 Technical Severity:
Severity High
Summary:
Summary During hot code load, BP did not reboot after relocation of the internal image.
Symptom:
Symptom Under very rare condition, sometime intelligent switch lost communication between BP and CP
and cause firmware download to fail with raslog SULB-1035 and switch would come up faulty.
This impacts Brocade 7500 and 7600
Workaround:
Workaround reboot for the new image to take effect.
Feature:
Feature Infrastructure Function:
Function Firmware Download
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000279401 Technical Severity:
Severity High
Summary:
Summary Internal race condition and semaphore lock contention caused FX8-24 initialization to fail and
switch to panic after blade hot plugged into the chassis
Symptom:
Symptom FX8-24 fails to initialize and causes a switch panic after being hot plugged into the chassis.
Workaround
Workaround:
karound Remove the GE SFP(s), put the blade in chassis and insert the SFPs after firmware auto-
leveling is completed.
Feature:
Feature Striker/Spike Platform Services Function:
Function BFOS
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000280910 Technical Severity:
Severity High
Summary:
Summary Added various optional RAS features to help identify slow drain device(s), handle stuck Virtual
Channels (VC), and credit loss conditions. Improved bottleneck detection on both 4G and 8G
platforms. Added transmit timeout counter support for 4G switches
Symptom:
Symptom Customer notices fabric performance being sluggish, SCSI timeout on hosts or fabric wide frame
drop. These can be triggered by several causes including a device port being slow, or credit issue
that backpressure frames into fabric. The Fabric will drop frames after a holding time is
exceeded. This release has optional RAS features that can be turned on to help customers
detect the existence of such problems and to identify the trouble spot or problem device(s). It
also allows setting different hold times at edge fabric to alleviate congestion if appropriate.
Feature:
Feature FABRIC WATCH Function:
Function PORT FENCING
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000283637 Technical Severity:
Severity High
Summary:
Summary Race condition encountered during extensive writes to compact flash causes long HA recovery
times during hot code load
Symptom:
Symptom Long HA recover times seen during hot code load. This can cause link reset or frame drops when
credit is not returned in time. Affects the VF environment and connecting switch operating under
single virtual channel credit model more extensively and can happen on both director and switch
platforms.
Feature:
Feature Infrastructure Function:
Function PDM/PortCfg
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000284426 Technical Severity:
Severity High
Summary:
Summary Brocade 5470 encountering extremely high enc out errors on ports connected to 3rd party HBAs
may experience link related problems
Symptom:
Symptom High "enc out" errors in the porterrshow CLI, which may cause link related problems.
Feature:
Feature Embedded Platform Services Function:
Function Balzer3
Probability:
Probability High
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000286104 Technical Severity:
Severity High
Summary:
Summary With FMS enabled and switch in VF mode, all ports on the FC8-48 become persistently disabled
after upgrading from FOS v6.2.x to FOS v6.3.x.
Symptom:
Symptom After upgrading from FOS v6.2.x to FOS v6.3.x on systems with FC8-48 blades installed, VF
disabled and fmsmode enabled, all ports on the FC8-48 blades become persistently disabled
without warning.
Workaround:
Workaround Manually re-enable ports, no other viable workaround at this time
Feature:
Feature Field Escalation Function:
Function FICON
Probability:
Probability High
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 423415
Where Else Fixed:
Fixed: FOS6.4.0
Defect ID:
ID DEFECT000286238 Technical Severity:
Severity High
Summary:
Summary Memory issues in manageability modules causes OOM panic during configDownload
Symptom:
Symptom Customer may experiences switch panic or cannot execute any command after shared memory
segments or memory shortage. It can be exposed via:
• Create and remove logical switch multiple times
• Perform configdownload with a large configuration file or repeat configdownload
• Run repeat perfresourceshow commands with option "eeRes" or "fportRes"
• Launch port admin and select GbE port tab and keep it open for long time (2 hours)
• Cald is busy to respond back to rpcd for some xml requests that cause stale shared memory
segments
Feature:
Feature OS Services Function:
Function Other
Probability:
Probability Low
Found in Release
Release:
ease FOS6.4.0
Defect ID:
ID DEFECT000286865 Technical Severity:
Severity High
Summary:
Summary Different PID formats between edge and backbone fabrics, after a large number of device
online/or insertion events, device import failed with FCR-1022 message
Symptom:
Symptom If backbone and edge fabric have different switch PID formats such as when edge fabric is in
IM2 mode, while backbone fabric is not, importing another device into the backbone will fail with
[FCR-1022] " Local proxy device slot entries exhausted" in raslog. Both 4G and 8G FCRs are
impacted and are more likely to be seen if there is frequent device offline/online in edge fabrics.
Feature:
Feature Field Escalation Function:
Function FCR
Probability:
Probability Low
Found in Release:
Release FOS6.1.0 Service Request ID:
ID 423429
Where Else Fixed: FOS6.4.0
Defect ID:
ID DEFECT000288756 Technical Severity:
Severity High
Summary:
Summary Not able to download fabricwatch settings to switch when there are mismatched names
(LinkReset/LReset) used in the configuration file
Symptom:
Symptom Unable to replicate Fabric Watch setting to switch using DCFM. Switch fails with raslog [CONF-
1023], 357, SLOT 7 | FID 128, INFO, , configDownload failed for switch. This will ONLY happen
when there is linkreset setting in configuration files, such as “thresh.cust.eport.Linkreset.above”
Workaround
Workaround: Once the switch is disabled, the configuration downloaded, and the switch re-enabled, the
configuration can be modified and downloaded without any problems. Or remove or comment
out the link reset settings in the .cfg file.
Feature:
Feature Field Escalation Function
Function:
nction Management Services
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.4.0
Defect ID:
ID DEFECT000289981 Technical Severity:
Severity High
Summary:
Summary Under very rare condition of a heartbeat lost while active is running FOS v6.3.x and standby CP is
running FOSv6.2.x, switch was reset.
Symptom:
Symptom Directors cold boot. This can only happen when heart beat was lost (such as backend Ethernet
connection had transient problem) while standby CP is on FOSv6.2.x and active CP is running
FOS6.3.x on directors, during firmware download.
Feature:
Feature High Availability Function:
Function Switch hareboot/HCL
Probability:
Probability Low
Found in Release:
Release FOS6.2.0
Defect ID:
ID DEFECT000297978 Technical Severity:
Severity High
Summary:
Summary Zoned terminated while activating zoning from DCFM
Symptom:
Symptom Unexpected reboot and failover if attempt to push zone DB from DCFM in IM2/IM3 fabrics only.
Workaround:
Workaround Use CLI (or ECFM for non-TI/Redirect zones) in IM2/IM3
Feature:
Feature FC Services Function:
Function Zoning
Probability:
Probability Medium
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000263476 Technical Severity:
Severity Medium
Summary:
Summary In fabric router environment, WWN for a device is showing up in multiple edge fabrics.
Symptom:
Symptom Proxy devices for the same host/target could be created in unintended fabric which could cause
traffic be sent to the wrong fabric and host does not see target. It happens when there is
frequent F port bounce (1-2 sec) in FCR fabric. This impacts all FCR platforms such as 7500,
FR4-18i and 8G Integrated Router platforms. This defect only exists in FOS v6.3.x.
Feature:
Feature 8G FCR Function:
Function FCR Daemon
Probability:
Probability Medium
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000269189 Technical Severity:
Severity Medium
Summary:
Summary SERDES tuning values to support BR–804 HBA
Symptom:
Symptom Fine tune SERDES value for BR–804 HBA support. This change only applies to Brocade 5480
platform.
Feature:
Feature Embedded Platform Services Function:
Function Bulova
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.4.0, FOS6.3.1 a
Defect ID:
ID DEFECT000270651 Technical
Technical Severity:
Severity Medium
Summary:
Summary 4G switch does not responding to Link Reset primitives correctly
Symptom:
Symptom Under a small timing condition, after reboot or switchdisable and switchenable, or when device
detect credit shortage, devices sent a LR to switch and switch does not respond to it and link
went down. This only applies to 4G switches/directors.
Workaround:
Workaround portdisable/portenable the ports a few times
Feature:
Feature FICON Function:
Function MS-FICON
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000281765 Technical Severity:
Severity Medium
Summary:
Summary AG NPIV port disabled as "initiator/target connected on N_Port" after upstream BES switch was
rebooted or a FS8-18 executes a Power On Self Test (POST).
Symptom:
Symptom When bpportloopbacktest is run as part of a POST on BES or FS8-18, loop back mode caused
the FLOGI frames from the AG ports on AG switch to loopback and further disable these AG ports
. Switchshow on AG switch reports:
0 0 5a0000 id N8 In_Sync FC Disabled (Initiator/Target connected to N-Port)
1 1 5a0100 id N8 No_Sync FC Disabled (Initiator/Target connected to N-Port)
Workaround:
Workaround Disable POST on BES or chassis with FS8-18 or reenable the AG ports manually
Feature:
Feature Diagnostics Function:
Function Other
Probability:
Probability High
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000281774 Technical Severity:
Severity Medium
Summary:
Summary After Brocade7800 reboot, seeing PLOGI aborts due to F_RJT for the ACCEPT frame
Symptom:
Symptom Host cannot see target if PLOGI comes in before RSCN is propagated on Brocade 7800 and FX8-
24 on VE port, due to backend port programming did not complete in time. This applies to both
FICON and non-FICON setup but only extension platform and on VE ports.
Feature:
Feature Striker/Spike Platform Services Function:
Function Spike Platform Module
Probability:
Probability Medium
Found in Release
Release:
ease FOS6.4.0
Defect ID:
ID DEFECT000283519 Technical Severity:
Severity Medium
Summary:
Summary Encryption switch panic due to daemon termination.
Symptom:
Symptom In corner case, BES switch or FS8-18 did not handle an error case correctly with key attribute
retrieval operation in daemon kacd.
Feature:
Feature Data Security Function:
Function Key Vault
Probability:
Probability Low
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 421755
Where Else Fixed: FOS6.4.0
Defect ID:
ID DEFECT000284435 Technical Severity:
Severity Medium
Summary:
Summary Switch panic after daemon iswitchd coredump
Symptom:
Symptom With two FCRs in the back bone and both are connect to same edge fabric through EX-ports, and
edge fabric has MEOS in IM2 mode, upon receiving periodic GE_PT from M-EOS switches, FCR
did not handle properly cause memory issues. Later iswitchd could coredump due to access to
the bad memory. switch is reboot/hafailover when it happens.
Feature:
Feature 8G FCR Function:
Function FCR Daemon
Probability:
Probability Low
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 421137
Where Else Fixed: FOS6.4.0
Defect
Defect ID:
ID DEFECT000287036 Technical Severity:
Severity Medium
Summary:
Summary portCfgFillWord enhancement for various 8G devices
Symptom:
Symptom In portCfgFillWord with fillword mode 3, a 3rd party device cannot come up on line. Workaround
the device issue by adding OLS as the trigger for the auto-switch from arb/arb to idle/arb when
port is configured to mode 3. In addition, for Brocade-804 Mez HBA, regardless what the mode
setting is on the port, it will operate at mode 1 internally with embedded switch Brocade 5480.
Feature:
Feature 8G Platform Services Function:
Function FOS Kernel Drivers
Probability:
Probability Low
Found in Release:
Release FOS6.3.1
Where Else Fixed: FOS6.3.1, FOS6.4.0
Defect ID:
ID DEFECT000287423 Technical Severity:
Severity Medium
Summary:
Summary Brocade 7800 and FX8-24 does not always auto-restart after detection of a critical error.
Symptom:
Symptom FOS 6.3.1 and 6.3.1a may not always auto-restart depending on the critical error encountered. A
manual reboot may be needed to recover Brocade 7800, and slotpower off/on to recover FX8-
24.
Feature:
Feature Striker/Spike Platform Services Function:
Function Blade Driver
Probability:
Probability High
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000287809 Technical Severity:
Severity Medium
Summary:
Summary Race condition on BES/FS8-18 node join/leave event causes encryption switch cluster to update
continuously and support save not to finish
Symptom:
Symptom Supportsave hangs after unplugging and then plugging in the network cable on BES/FS8-18
platforms
Feature:
Feature Data Security Function:
Function Infrastructure
Probability:
Probability Low
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000288832 Technical Severity:
Severity Medium
Summary:
Summary On Brocade 5460 platform, firmware version was being set to the FOS default value string, not
the proper version string
Symptom:
Symptom Firmware version string always shows FOS default on Brocade 5460, not the correct version
through 3rd party SVP.
Feature:
Feature Embedded Platform Services Function:
Function Sys-Control/Environment Monitor
Probability:
Probability Low
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000290539 Technical Severity:
Severity Medium
Summary:
Summary On the Brocade 300, 5100, and 5300 switches shipped from the factory with FOS v6.3.0a, b, c,
d, v6.3.1 and v6.3.1a, the assignment of PIDs (FCIDs) is non-deterministic.
Symptom:
Symptom If customer has factory installed switches (Brocade 5300, 5100 and Brocade 300), shipped with
FOS v6.3.0a,b,c,d, FOS v6.3.1, and FOS v6.3.1a, the area field of the PIDs will be assigned
based on the order ports are recognized and brought up by the system the first time (and only
the first time) it is booted. Each Switch port PID’s area will not equal its port number, which may
impact servers (such as FICON servers, or static PID binding servers) that need their area equal
to the port numbers to login to the fabric successfully. This issue does not impact switches that
are upgraded from FOS v6.2.x to v6.3.0a,b,c,d, v6.3.1 and v6.3.1a, as PIDs are persistent
across reboot and upgrade once they are assigned. An example of non-port based assigned PIDs
from switchshow:
0 0 401700 -- N8 No_Module FC
1 1 401500 -- N8 No_Module FC
Workaround:
Workaround In environments with devices that rely on the area of the PID to match the port number, users
should bind PIDs using the portaddress --bind [slot_number/]port_number [16-bit_address]
command prior to allowing devices to log in to switch.
Feature:
Feature 8G Platform Services Function:
unction PID management
Probability:
Probability Medium
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000290556 Technical Severity:
Severity Medium
Summary:
Summary Host fails to discover LUNs when more than 64 LUNs are added to BES from Storage Array
Symptom:
Symptom The host which implements strict FCP/FCP-2 protocol frame fields checking for EOF delimiter will
not detect LUNs when more than 64 LUNs are added to BES from storage array. This also
impacts FS8-18 blades.
Feature:
Feature Data Security Function:
Function Disk Encryption
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 426663
Defect ID:
ID DEFECT000298120 Technical Severity:
Severity Medium
Summary:
Summary Port based routing frame were out of order when FCP image pairs concurrently initiate
exchanges as originators over GE ports
Symptom
Symptom:
ptom 3rd party device has very poor performance over FCIP link between two Brocade 7800 over 1G
GE port. Same issue applies to FX8-24 blades.
Feature:
Feature FCIP Function:
Function FCIP Performance
Probability:
Probability Medium
Found in Release:
Release FOS6.3.1 Service Request ID:
ID 429767
Defect ID:
ID DEFECT000249582 Technical Severity:
Severity High
Summary:
Summary DPC crash caused Brocade 7600 or FA4-19 blade goes to faulty.
Symptom:
Symptom When BP is rebooted in a middle of a PCI access cycle, the PCI cycle is not getting terminated
properly. This result in a DPC crash. Customer could see Brocade 7600 or FA4-18 reports faulty
during boot and raslog BL-1020 indicated switch timing out while initializing ASIC chips.
Feature:
Feature FA4-18 Platform Services Function:
Function 1250: ANZIO DRIVER
Probability:
Probability Low
Found in Release:
Release FOS6.2.0
Defect ID:
ID DEFECT000272207 Technical
Technical Severity:
Severity High
Summary:
Summary Enhancement request to add a user selectable parameter to adjust SFP polling during high CPU
load situation.
Symptom:
Symptom The new parameter is under System category of configurechassis CLI: %> configurechassis
Configure... System (yes, y, no, n): [no] y system.cpuLoad: (10..121) [121] 20 Default is 121,
represent CPU instantaneous load average of 1.21, first number in load average in uptime or top
command. So by default, CPU will poll sfp when load is 1.21 or lower. Use this parameter to
adjust SFP polling to avoid laser fault condition [C2-5678] causes links to reset under high CPU
load.
Feature:
Feature Field Escalation Function:
Function OS: Infrastructure
Probability:
Probability High
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 409677
Defect ID:
ID DEFECT000277488 Technical Severity:
Severity High
Summary:
Summary Observed ASSERT - Failed expression: fabSysDynamicAreaSupported(sw->sw_inst) after
firmwarecommit
Symptom:
Symptom Observed HAM-1007 and HAM-1009 MANUALLY REBOOT the system for recovery - auto-reboot
is disabled. Sometime both CPs fail and switch cannot boot up. This happens only when a
configuration file for dynamic area mapping is corrupted which is very rare.
Workaround:
Workaround Remove the port2Bound file in /etc/fabos/port2Bound files in both active CP and standby
CPs, also in both partitions on both CP, after that, reboot the switch.
Feature:
Feature 8G Platform Services Function:
Function FOS Kernel Drivers
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000280165 Technical Severity:
Severity High
Summary:
Summary Switch detected termination of daemons due to bad EOFa frames are forward to application
rather than dropped in 8G driver
Symptom:
Symptom Under rare situation (such as marginal hardware), switch may see corrupted EOF frames
forwarded to CPU for processing. 8G driver did not drop such frame and passed to upper layer
application demons. This can cause switch panic or hafailvoer.
Feature:
Feature 8G Platform Services Function:
Function FOS Kernel Drivers
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000282795 Technical Severity
Severity:
verity High
Summary:
Summary Host failed to discover tapes due to a VI/VT database mismatch between the switches that are
part of the same Encryption Group
Symptom:
Symptom Host will not able to discovery Tape devices that are part of the same EG
Workaround:
Workaround Issue "cryptocfg --commit" again to sync up the VT/VI database across nodes in the EG.
Feature:
Feature Data Security Function:
Function Tape Encryption
Probability:
Probability Low
Found in Release:
Release FOS6.3.1
Where Else Fixed: FOS6.3.1, FOS6.3.0 c
Defect ID:
ID DEFECT000283046 Technical Severity
Severity:
everity High
Summary:
Summary GID_PN from a VI for any other Virtual Entity instantiated on the same port (same area) succeeds
even though the entities are not zoned with VI
Symptom:
Symptom Zoning restriction did not work for NPIV/loop ports when one device tries to get other device
information on the same port using name based queries (GID_PN, GID_NN). This could cuase
SAS attempt to talk to devices fail.
Feature:
Feature SAS Function:
Function VI
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269189 Technical Severity:
Severity Medium
Summary:
Summary SERDES tuning values to support BR–804 HBA
Symptom:
Symptom Fine tune SERDES value for BR–804 HBA support. This change only applies to Brocade 5480
platform.
Workaround:
Workaround No
Feature:
Feature Embedded Platform Services Function:
Function Bulova
Probability
Probability:
ility Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270261 Technical Severity:
Severity Medium
Summary:
Summary CP/switch fails to boot on DCX, DCX-4s and Brocade 5300.
Symptom:
Symptom CP does not boot on power up or fails during hafailover with CF access error; "HDA: drive not
ready" message sometimes are seen on console.
Workaround:
Workaround Reboot switch again
Feature:
Feature OS Services Function:
Function Linux Kernal
Probability:
Probability Low
Found in Release:
Release FOS6.2.0
Defect ID:
ID DEFECT000272847 Technical Severity:
Severity Medium
Summary:
Summary 8-bit area address is not properly range checked
Symptom:
Symptom Firmware upgrade may fail with segment fault from FOS 6.3.x to a future FOS release when there
is multiple LS non-continuous switch instances.
Feature:
Feature Quattro Function:
Function Kernel Driver
Probability:
Probability Medium
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000279687 Technical Severity:
Severity Medium
Summary:
Summary Switch panic after detecting termination of process webd:1130
Symptom:
Symptom Perform multiple configdownload through DCFM or CLI can trigger memory issues with webd.
most time webd will restart and at time this could trigger switch panic.
Feature:
Feature Field Escalation Function:
Function Web Management
Probability:
Probability Low
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 416939
Defect ID:
ID DEFECT000279834 Technical Severity:
Severity Medium
Summary:
Summary Encountered "(SAS) Application installation failed. Switch does not support SAS." message on
Brocade 7600 when upgrade/downgrade SAS
Symptom:
Symptom SAS upgrade fails with "(SAS) Application installation failed. Switch does not support SAS."
message. This happens when a race condition triggers a CLI (slotshow) that firmwaredownload
relies fails.
Workaround:
Workaround Try firmwaredownload again to upgrade SAS when it fails
Feature:
Feature FIRMWARE DOWNLOAD Function:
Function Firmware Download
Probability:
Probability Medium
Found
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000283300 Technical Severity:
Severity Medium
Summary:
Summary TCP connection is torn down prematurely.
Symptom:
Symptom Failure to clean up the locally managed socket caused application to read from stale sockets
and drop the TCP connection. This only impact encryption platforms (BES, FS8-18)
Feature:
Feature Data Security Function:
Function HA Cluster
Probability:
Probability Medium
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000283740 Technical Severity:
Severity Medium
Summary:
Summary Host hangs while scanning LUNs.
Symptom:
Symptom Customer can scan 2 cleartext LUNs (0 and 1) but cannot scan encrypted LUNs 2-7 on some
device types.
Feature:
Feature Field Escalation Function:
Function Encryption
Probability:
Probability Low
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 421053
Defect ID:
ID DEFECT000284472 Technical Severity:
Severity Medium
Summary:
Summary SCR is not properly registered in the name server
Symptom:
Symptom After upgrade from FOS v6.2.x to FOS v6.3.0x or FOS v6.3.1, reboots/bounce a target port,
RSCNs are not sent to all devices the target is zoned with. Hosts are unable to see the target
until all hosts port are bounced. This defect only happened with FOS v6.3.x upgrade. It impacts
all platforms with FC ports, both Ficon and non-ficon enviorment.
Workaround:
Workaround need to bounce port to recover, or upgrade to the version with fix
Feature:
Feature Field Escalation Function:
Function Fabric Services
Probability:
Probability High
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 421925
Defect ID:
ID DEFECT000285251 Technical Severity:
Severity Medium
Summary:
Summary DPC Online event is not delivered to storage application due to a timer issue
Symptom:
Symptom DPC-0 Online is not delivered to Storage Application. This applies to FA4-8 and AP7600 only.
Feature:
Feature FA4-18 Platform Services Function:
Function Blade FOS SW
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000285372 Technical Severity:
Severity Medium
Summary:
Summary VI/VTs goes OFFLINE post a DPC crash.
Symptom:
Symptom In a rare DPC crash case, RSCN was not sent out in time, caused VI/VT goes offline. This is
limited to FA4-18 and AP7600 platforms.
Feature:
Feature FA4-18 Platform Services Function:
Function 1250: OS SUPPORT
Probability:
Probability Medium
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000279946 Technical Severity:
Severity Critical
Summary:
Summary Customer unable to remove Admin domains, SFC rejected errors sent by AD3
Symptom:
Symptom When execute command cfgdisable, gets the following message:Too many devices found
(>120) in default zone.
Workaround:
Workaround 1. Migrated all devices to AD0 before as outlined in the AD migrate instructions. 2. Remove
the devices from the ADs using the: ad --select 255 ad --remove <ADnum> -d “<devices to
remove separated by semicolon>” ad --apply 3. Perform ‘ad --clear –f’ followed by ‘ad --apply’
from the AD255 context and this should remove the ADs properly.
Feature:
Feature Field Escalation Function:
Function Fabric Services
Probability:
Probability Medium
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 412409
Defect ID:
ID DEFECT000240850 Technical Severity:
Severity High
Summary:
Summary With SNMP severity set to 3, the DCX sends out traps when a core blade is inserted, but not
when it is removed
Symptom:
Symptom Traps not sent out when a core blade is removed and SNMP severity set to 3
Feature:
Feature Field Escalation Function:
Function Management Services
Probability:
Probability Medium
Found in Release:
Release FOS6.1.0 Service Request ID:
ID 361769
Defect ID:
ID DEFECT000260338 Technical Severity:
Severity High
Summary:
Summary After blade fault, port was taken off line at ASIC level but offline SCN was not sent to
applications such as routing module, fspfd, fabric which created an inconsistent view between
application and kernel on the port state of the faulted blade.
Symptom:
Symptom After a blade fault, a replacement blade would fault due to frame count mismatch during POST,
as there are still frames sent to offline port by upper layer application, fabric unstable as fabric
attempts to build fabric through offline port, and hosts connected to the replacement blade
have problem logging back into the fabric with "Switch not ready for F or L port" message.
Feature:
Feature Field Escalation Function:
Function ASIC Driver
Probability:
Probability Low
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 391827
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000261638 Technical
Technical Severity:
Severity High
Summary:
Summary TI zones become disabled when telnet times out following TI zone change
Symptom:
Symptom Set telnet timeout to 1 minute, logout/login to have timeout take effect, created new TI zone,
waited for telnet session to timeout, log back into switch and issue cfgsave; cfgsave actually
pushes data, which shouldn't occur as the session timed out. Without properly terminating stale
transaction before processing a new TI zone can result in erroneous TI zone properties list and
trigger other fabric-wide instability events such as no route, rtwr errors in fabric etc.
Feature:
Feature Field Escalation Function:
Function Fabric Services
Probability:
Probability Medium
Found in Release:
Release FOS6.1.1 Service Request ID:
ID 394553
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000263300 Technical Severity:
Severity High
Summary:
Summary switchshow shows all PIDs the same after reboot
Symptom:
Symptom After switch came back up from reboot, nsshow was empty, all the PIDs are the same for all the
ports that all online, and all online ports have the same address due to recovery messed up
port to area map on pizza box for FOS 6.1->6.2->6.3 warm upgrade code path.
Feature:
Feature 8G Platform Services Function:
Function PID management
Probability:
Probability Low
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 398903
Defect ID:
ID DEFECT000265158 Technical Severity:
Severity High
Summary:
Summary Under very uncommon Fabric Watch setting, Fabric Watch daemon can crash.
Symptom:
Symptom If fwalarms is turned off and Errlog is turned on in Fabric Watch configuration, Fabric Watch
daemon can crash and lead to switch panic.
Workaround:
Workaround In the threshold alarm matrix configuration for all port related thresholds, disable ErrLog and
Port Fencing (using fwconfigure) this will avoid the above functions from being called (on any
threshold events) and leaking or enable fwalarmsfilterset
Feature:
Feature Field Escalation Function:
Function Panic / OOM
Probability:
Probability Low
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 398779
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000267411 Technical Severity:
Severity High
Summary:
Summary Executing configdownload caused fcoed died
Symptom:
Symptom switch got rebooted
Feature:
Feature CEE-FCOE Function:
Function FCOE Daemon
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000267476 Technical Severity:
Severity High
Summary:
Summary Brocade 7800 panic during overnight workload
Symptom
Symptom: Brocade 7800 switch crashed and FCIP I/O stopped during overnight workload over 4G Tunnel
testing.
Feature:
Feature Striker/Spike Platform Services Function:
Function Blade Driver
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000268714 Technical Severity
Severity:
verity High
Summary:
Summary ONMD is crashing continuously when the links were coming up
Symptom:
Symptom Saving the configuration with LLDP disabled leads to crash when switch rebooted
Feature:
Feature CEE-LAYER2 Function:
Function LLDP
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269513 Technical Severity:
Severity High
Summary:
Summary Non-VF mode on DCX, enabled the F-Port Trunk and then enabled the Dynamic Area Addressing
mode, changing to DAA mode cause Trunk area to be disabled.
Symptom:
Symptom Check F-Port Trunk using "porttrunkarea --show enabled", it returned "No ports have Trunk Area
enabled" and there was no F-Port TRUNK anymore.
Feature:
Feature 8G Platform Services Function:
Function Other
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000269997 Technical Severity:
Severity High
Summary:
Summary Cascaded CUP failure when channel on Brocade 48000 8G blade and E Port is on different chip
Symptom:
Symptom no cascaded CUP connectivity when channel on Brocade 48000 8G blade and E port are on
different ASIC chip.
Feature:
Feature 8G ASIC Driver Function
Function:
on C2 ASIC driver
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270038 Technical Severity:
Severity High
Summary:
Summary Daemon crash on logical switch creation-deletion
Symptom:
Symptom Fabric daemon panic due to the shared memory info got corrupted during logical switch
creation-deletion testing loop.
Feature:
Feature FC Services Function:
Function Zoning
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270373 Technical Severity:
Severity High
Summary:
Summary On Brocade 7800, no NPIV devices (including AG) can log into ports in the first quad of FR4-18
blade /Brocade 7500
Symptom:
Symptom The AG port gets disabled with a message stating NPIV not supported on Fabric port although
NPIV is enabled on the 7800 ports. The same NPIV based device logs in as expected with the
FLOGIs + FDISCs in any other port from 4-31.
Feature:
Feature 4G Platform Services Function:
Function FOS Kernel Drivers
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270813 Technical Severity:
Severity High
Summary:
Summary Switch is not accessible through Web Tools after firmware upgrade to FOS v6.3.0a
Symptom:
Symptom After upgrade from v6.2.x to v6.3.x Web Tools cannot be accessed via name or across a NAT
network connection. In either instance the following message is displayed; Not a Management
IP Address, The IP address given is not one of the management addresses. Use 10.100.2.108 .
With NAT the real address of the switch is displayed. On a non-NAT environment access via IP
address works. Access via Switchname gets the same response again displaying the switch ip
address.
Workaround:
Workaround Access switch via IP address
Feature:
Feature Mgmt Embedded - HTTP Function:
Function Other
Probability:
Probability High
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 408403
Defect ID:
ID DEFECT000271111 Technical Severity:
Severity High
Summary:
Summary RTWR messages are logged when more than 16 dynamic paths are setup to remote domains
Symptom:
Symptom On Brocade 5300, 300, and 8G embedded switches, when more than 16 dynamic path routes
are set up to remote switches, it is possible that parity errors can be generated by the switch
and indicated by internal raslog C2-5658. Customer can experience path loss and traffic
interruption.
Workaround:
Workaround Limit the number of dynamic paths on these platforms. Note: if there are more than 16
dynamic paths already on these platforms, upgrade to the fixed release could be a cold
recovery
Feature:
Feature Field Escalation Function:
Function Fabric Services
Probability:
Probability Medium
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 406617
Defect ID:
ID DEFECT000273098 Technical Severity:
Severity High
Summary:
Summary Response time for small read request between FCIP connection takes over 10 msec.
Symptom:
Symptom Observe 2-4ms delay between the time something arrives on the GE port until its sent out the
FC port
Workaround:
Workaround Do not run low IO rate traffic. Only occurs when low IO rate traffic is passing through the FCIP
Tunnel.
Feature:
Feature FCIP Function:
Function FCIP I/O
Probability:
Probability Low
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 409943
Defect ID:
ID DEFECT000273131 Technical Severity:
Severity High
Summary:
Summary FCOE10-24 getting into Faulty (21) mode during stress testing.
Symptom:
Symptom Backend port fault triggered blade fault with raslog: [EM-1034], 22744, SLOT 4 | CHASSIS,
ERROR, , Slot 2 set to faulty, rc=20015.
Feature:
Feature CEE-Infrastructure Function:
Function ANVIL DRIVER
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000273514 Technical Severity:
Severity High
Summary:
Summary FC FastWrite host cannot see target after target port bounce due to cam setup problem on
backend port used by FC FastWrite
Symptom:
Symptom Not able to recover FC FastWrite paths after device maintenance was performed, or remote
target port is bounced.
Feature:
Feature Field Escalation Function:
Function FCIP Flipper/ASIC
Probability:
Probability Medium
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 410681
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000275630 Technical
Technical Severity:
Severity High
Summary:
Summary DCX crashed while attempting to change TE Port from LAG to trunk mode
Symptom:
Symptom When port is changed from standard mode LAG to trunk port, the switch crashed due to ssmd
core dump.
Feature:
Feature CEE-SYSTEM SERVICES Function:
Function SSM
Probability
Probability:
obability High
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000277444 Technical Severity:
Severity High
Summary:
Summary Switch may panic after executing fcplunquery or iscsicfg CLI command for tgt entity on FC4-
16IP.
Symptom:
Symptom FCPd termination occurred if PRLI or Report LUN query timeout during fcplunquery/iscsicfg CLI
and LOGO response comeback without a message queue to process it. This only impacts FOS
v6.2.2 and FOSv6.3.0c
Feature:
Feature FC Services Function:
Function FCP
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Where
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000277814 Technical Severity:
Severity High
Summary:
Summary FCOE10-24 blade installed in the highest slot in a chassis based system does not send out UA's
(unsolicited advertisements)
Symptom:
Symptom FCOE10-24 blade installed in highest slot is up and running but will not support any FCoE
because there is no UA's being transmitted from the blade
Workaround:
Workaround Install FCOE10-24 to lower slot
Feature:
Feature CEE-FCOE Function:
Function FCOE PROTOCOL
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect
Defect ID:
ID DEFECT000278788 Technical Severity:
Severity High
Summary:
Summary Switch displays incorrect information upon userconfig --show command execution
Symptom:
Symptom changes to the admin password on a switch are not being recorded properly. - Specifically the
"Password Last Change Date" shows incorrect date (1 day off).
Feature:
Feature UNDETERMINED Function:
Function UNDER REVIEW
Probability:
Probability Low
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 416529
Defect ID:
ID DEFECT000244679 Technical Severity:
Severity Medium
Summary:
Summary Fabric Watch SFP messages logged invalid value
Symptom:
Symptom I2C read values of 0xFF and I2C NACK error case are not properly handled caused
improbable/unpredictable values to be reported by Fabric Watch on SFP.
Feature:
Feature Field Escalation Function:
Function EM / Hil / Sysctrl
Probability:
Probability Low
Found in Release:
Release FOS6.1.1 Service Request ID:
ID 370901
Defect ID:
ID DEFECT000252641 Technical Severity:
Severity Medium
Summary:
Summary Configdownload doesn't load the tstimezone info.
Symptom:
Symptom Setup tstimezone, upload the configuration to a ftp server. After changing the tzh and tzm in the
config.txt file to a new value, and running configdownload to put the config.txt file on the switch.
Issue tstimezone command, the timezone is not changed.
Workaround:
Workaround Setup tstimezone through CLI.
Feature:
Feature Fabric Infrastructure Function:
Function Time Server
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000254565 Technical Severity:
Severity Medium
Summary:
Summary After upgrade to FOSv6.x, script fails due to rsh switch with user account credential and
execute command "ifmodeshow" output errors and inaccurate output.
Symptom:
Symptom Telnet works, rsh with root credential work, only rsh using user credential gets "ifmodeshow
eth0": ioctl(ETHTOOL_GSET) failed.
Workaround:
Workaround Set suid permissions for ethmode: chmod +s /fabos/libexec/ethmode
Feature:
Feature Field Escalation Function:
Function OS: Linux
Probability:
Probability Medium
Found in Release:
Release FOS6.0.1 Service Request ID:
ID 382985
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000258327 Technical Severity:
Severity Medium
Summary:
Summary 4G SFPs do not consistently show data in sfpshow on Brocade 7800 GbE ports
Symptom:
Symptom 4G SFP data is not shown on Brocade 7800 GbE ports, sfpshow reports"Cannot read serial
data", or correct sfp serial number or 'nothing at all'.
Feature:
Feature Striker/Spike Platform Services Function:
Function BCM Driver
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000258330 Technical Severity:
Severity Medium
Summary:
Summary EX_Port Rejected Fabric Binding for Edge Fabric in IM3
Symptom:
Symptom Fabric binding will not work in 239 domain mode in IM3 with FCR
Feature:
Feature 8G FCR Function:
Function FCR Security
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000260099 Technical Severity:
Severity Medium
Summary:
Summary Support auto-assignment of slot-Based licenses and address slot based license issues
Symptom:
Symptom slot based license feature is enhanced.
Feature:
Feature License Function:
Function License
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000260552 Technical Severity:
Severity Medium
Summary:
Summary Fabric Watch messages logged with values above 100%.
Symptom:
Symptom Fabric Watch FW-1186 & FW1190 messages are being logged with percentages above 100%,
which is not possible. This is likely to happen during the first Fabric Watch polling cycle after
slotstatsclear command has been issued.
Feature:
Feature Field Escalation Function:
Function Management Services
Probability:
Probability Low
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 384439
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000260572 Technical Severity:
Severity Medium
Summary:
Summary Zone changes of Fabric Class does not work
Symptom:
Symptom 'Zoning Changes' of 'Fabric class areas' in fwconfigure does not function correctly
Feature:
Feature Fabric Infrastructure Function:
Function Fabric Watch
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000260700 Technical Severity:
Severity Medium
Summary:
Summary Unable to load IF.mib and SW.mib in AdventNet MIB Browser
Symptom:
Symptom The user will not be able to load IF.mib and SW.mib
Feature:
Feature Mgmt Embedded - SNMP Function:
Function Other
Probability:
Probability High
Found in Release
Release:
ase FOS6.3.0
Defect ID:
ID DEFECT000261246 Technical Severity:
Severity Medium
Summary:
Summary HA synchronization lost after a switch with trunk ports panic and manual reboot was needed to
recover.
Symptom:
Symptom After hafailover, HA component did not get fabric stable due to race condition with trunk ports
dropping EFP response. This condition is rare but if it happens, manual reboot is needed to
recover.
Feature:
Feature Field Escalation Function:
Function Management Services
Probability:
Probability Low
Found in Release:
Release FOS6.2.0 Service Request ID
ID: 393141
Defect ID:
ID DEFECT000261663 Technical Severity:
Severity Medium
Summary:
Summary Clean up printf to eliminate error and error message: "ssnGet: Unable to get WWN info.sw=0
rc=-5"
Symptom:
Symptom The following message may pop up to console while firmware is in process of committing:
"ssnGet: Unable to get WWN info.sw=0 rc=-5".
Feature:
Feature System Controls/EM Function:
Function DCX/DCX-4S
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000262942 Technical Severity:
Severity Medium
Summary:
Summary Faulty CP is not displayed in Web Tools
Symptom:
Symptom The display of the CP blade disappears from Web Tools when the CP blade became faulty.
Feature:
Feature WebMgmt Function:
Function Switch Explorer/Switch View
Probability:
Probability Medium
Found in Release:
Release FOS6.2.0 Service Request
Request ID:
ID 399755
Defect ID:
ID DEFECT000263500 Technical Severity:
Severity Medium
Summary:
Summary After using ipaddrset, incorrect CP hostname is displayed on standby CP
Symptom:
Symptom Login prompt of StandbyCP show incorrectly after set Host name of CP Blade by ipaddrset -cp
command
Feature:
Feature Field Escalation Function:
Function OS: Infrastructure
Probability:
Probability High
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 399361
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000263704 Technical Severity:
Severity Medium
Summary:
Summary Byte Streaming support on 7500/FR4-18i does not work with 3rd party Optimizers
Symptom:
Symptom 1250 panics when running byte streaming code when connected through a 3rd party optimizer.
Feature:
Feature Legacy FCIP (7500/FR4-18i) Function:
Function FCIP I/O
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000263889 Technical Severity:
Severity Medium
Summary:
Summary Brocade 200E and 4G based embedded platform speed negotiation fails when lock port as
G_Port
Symptom:
Symptom Switch port cannot come on line when reboot connected server sometimes. This applies to
Brocade 200E and 4G embedded platforms only.
Feature:
Feature Field Escalation Function:
Function ASIC Driver
Probability:
Probability Low
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 400493
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000263930 Technical Severity:
Severity Medium
Summary:
Summary portbeacon command is not found
Symptom:
Symptom User cannot turn on/off port beacon on FOS v6.3.0x
Feature:
Feature 4G Platform Services Function:
Function Sys-Control/Environment Monitor
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000264548 Technical Severity:
Severity Medium
Summary:
Summary CALD failed, but no failover happened – cald stuck as <defunct>
Symptom:
Symptom CALD panic occurred at customer site, CPs became out of sync, and a manual reboot was
required of the active CP to recover. The ps output still contains cald, however it is in a
<defunct> state. 4 0 30056 2497 16 0 0 0 - Z ? 0:01 \_ cald <defunct>
Workaround:
Workaround Manually reboot.
Feature:
Feature Field Escalation Function:
Function Management Services
Probability:
Probability Low
Found in Release:
Release FOS6.2.0 Service Request ID
ID: 400805
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000265119 Technical Severity:
Severity Medium
Summary:
Summary Rebooting backbone host is unable to discover common zone target in the edge fabric.
Symptom:
Symptom Timing window exists where a SID zone miss could drop a frame. Initiator that does not retry
PLOGI will fail to discover targets of edge fabric.
Workaround:
Workaround Workaround (recovery) is to disable/enable the target.
Feature:
Feature Striker/Spike Platform Services Function:
Function VEX
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265165 Technical Severity:
Severity Medium
Summary:
Summary DCX/DCX-S4 experiences repeat assert panic on emd during high temperature testing.
Symptom:
Symptom During power off/on switch test with DCX/DCX-4S under stressed environment condition, switch
experienced panic rather than blade fault. This could happen when blades get too hot, or there
is a bad temperature sensor, or a spurious sensor reading.
Feature:
Feature Field Escalation Function:
Function EM / Hil / Sysctrl
Probability:
Probability Low
Found in Release:
Release FOS6.2.0
Defect ID:
ID DEFECT000265327 Technical Severity:
Severity Medium
Summary:
Summary Observe C2-5464/5465 errors every time power cycling switch with FCoE ports.
Symptom:
Symptom Cold reboot switch, observe internal raslog flood due logical port to FCoE virtual user port
mapping error.
Feature:
Feature 8G ASIC Driver Function:
Function C2 ASIC driver
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265647 Technical Severity:
Severity Medium
Summary:
Summary Bottleneck configurations are not backed up in AG
Symptom:
Symptom Configuration back up on AG does not have the bottleneck configurations.
Feature:
Feature FC Services Function:
Function Bottleneck Management
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000265865 Technical Severity:
Severity Medium
Summary:
Summary ARB(ff) usage as fill words for 8Gb connectivity does not abide by the standards
Symptom:
Symptom IDLE/ARBFF mode 2 is now available and added mode 3 which will perform mode 1
(ARBF/ARBFF) via hardware state machine; Depends on device behavior, different modes are
configurable.
Feature:
Feature 8G ASIC Driver Function:
Function ASIC Driver
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000267596 Technical Severity:
Severity Medium
Summary:
Summary When port cfgdefault is issued on VE port, error messages are POSTED on DP and CP
Symptom:
Symptom portcfgdefault 4/22: Port 182 NPIV Limit Set to 126! Unknown Error
Workaround:
Workaround Do not issue the portCfgDefault command on FX8-24/7800 VE ports.
Feature:
Feature FCIP Function:
Function FCIP Port
Probability:
Probability Medium
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000267637 Technical Severity
Severity:
ity Medium
Summary:
Summary Access Gateway responding to misdirected LOGO on 48-port blade.
Symptom:
Symptom When AG switch is connecting to a secondary port on FC4-48 or FC8-48. If the primary port
goes down, some frames might be wrongly routed to the AG switch's secondary port, AG
respond to these frame with ACC rather than drop.
Workaround:
Workaround Do not put AG switch at the secondary port on 48-port blades
Feature:
Feature Field Escalation Function:
Function Access Gateway
Probability:
Probability Low
Found in Release:
Release FOS6.1.1 Service Request ID:
ID 404527
Defect ID:
ID DEFECT000268665 Technical Severity:
Severity Medium
Summary:
Summary During reboot, the NPIV device is sending the explicit logout. Switch does not clean up route
properly.
Symptom:
Symptom NPIV tape devices may not be seen by any of the hosts
Feature:
Feature FC Services Function:
Function NPIV
Probability:
Probability Low
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 405453
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000268808 Technical Severity:
Severity Medium
Summary:
Summary portlog parameters are not persistent after hafailover
Symptom
Symptom: After hafailover, the portlog parameters "debug" and "Portlog events enable" goes back to
default, or setting in previous reboot rather than the new setting before hafailover.
Feature:
Feature Infrastructure Function:
Function Config Download
Probability:
Probability Low
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 405519
Defect ID:
ID DEFECT000268938 Technical Severity:
Severity Medium
Summary:
Summary After reboot Brocade 8000 switch, monitored flood of internal RASLOG message on FCOE/NPIV
port.
Symptom:
Symptom WWN entries are actually logged into the switch but observe flood of FCOE-5026 internal raslog
meesage as: WARNING, Brocade8000, fcoe_process_login_rsp: AVL entry deleted for WWN :
10:00:88:88:33:00:00:02 , fcoe_login.c, line 1840. No other functional impact.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269267 Technical Severity:
Severity Medium
Summary:
Summary After upgrade from FOS v6.2.x to FOS v6.3.0b/c and then downgrade back down to FOSv6.2.0x,
observe critical message "BKSW-5002 " swd_drv.c, line: 1323
Symptom:
Symptom Observed kSWD: SWDIoctl: pid=480 request unknown IOCTL type 1074026240 after
downgrade due to a new file descriptor introduced in FOS v6.3.0b/c.
Feature:
Feature High Availability Function:
Function HA infrastructure
Probability:
Probability Medium
Found
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269632 Technical Severity:
Severity Medium
Summary:
Summary FCIP tunnel bounce with impairment test..
Symptom:
Symptom Observe tunnel bounce while testing with following impairment test: * 100msec latency *
corrupt 1 byte in 1 frame in 200k * drop 1 frame in 500k frames
Workaround:
Workaround Identify and fix cause of TCP Network retransmissions. Reduce tunnel maximum data rate to
level that does not experience packet loss or corruption on the network.
Feature:
Feature FCIP Function:
Function FCP TCP/IP Stack
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269691 Technical Severity:
Severity Medium
Summary:
Summary Support for arrays that support SPC-2 - LSN identification
Symptom:
Symptom Some array, although it supports SPC-3 but indicates in the standard inquiry data that it
supports SPC-2. This causes the LUN to show up with a different LUN number on a different
path.
Feature:
Feature Data Security Function:
Function Disk Encryption
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000269935 Technical Severity
Severity:
rity Medium
Summary:
Summary Loop port takes long time to come up in IM2/IM3 mode
Symptom:
Symptom There is a time window during ELP process, it can cause a loop port to take more than 15 to 20
sec to come up
Feature:
Feature FC Services Function:
Function Fabric
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000270065 Technical Severity:
Severity Medium
Summary:
Summary Observed VE tunnel bounce after a hareboot on edge switch on Brocade 7800
Symptom:
Symptom iswitchd disable port due to fspf timeout prematurely during hafailover under heavy load.
Feature:
Feature 8G FCR Function:
Function FCR Daemon
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270325 Technical Severity:
Severity Medium
Summary:
Summary Switch no longer shows the error message to indicate an invalid zone name and enforcement of
64 characters on zone name is conflicting.
Symptom:
Symptom zonecreate 3zone2,"1,1" no longer report error. There is no other functional impact as the zone
is not enabled. cfgcreate/zonecreate is also updated to prevent the creation of a cfg/zone
name greater than with 64 chars but allow zone/alias names greater than 64 chars in the list.
Feature:
Feature Field Escalation Function:
Function Fabric Services
Probability:
Probability Low
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 404027
Defect ID:
ID DEFECT000270381 Technical Severity:
Severity Medium
Summary:
Summary Configure terminal/config terminal 0 fails sometimes with message IMISH DEBUG CONNECT
Symptom:
Symptom When tests does '<telnet session open> => cmsh => configure terminal => <does some
configuration>=> <close telnet session>' sequence repeatedly to configure/unconfigure the
DUT, sometimes, the 'configure terminal' command fails, and the 'config' prompt was not
obtained.
Feature:
Feature CEE-MANAGEABILITY Function:
Function CLI
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270683 Technical Severity:
Severity Medium
Summary:
Summary LDAP 2008 support
Symptom:
Symptom User name/password authentication may fail.
Feature:
Feature FOS Security Function:
Function LDAP
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000272519 Technical Severity
Severity:
everity Medium
Summary:
Summary Change requirement to remove trial license before allowing non-trial license installation.
Symptom:
Symptom Customer need to remove trial licenses prior to installing permanent license for same feature.
Feature:
Feature License Function:
Function License
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000272635 Technical Severity:
Severity Medium
Summary:
Summary After setting the SNMPv3 by "snmpconfig --set snmpv3", the
"snmp.snmpv3Keys.*.usmPrivKeySize:" parameter does not begin from a new line
Symptom:
Symptom switch failed configDownload with following message: snmp.snmpv3Usm.0.usmPrivProtocol:6
Invalid Value. Process function of configdownload failed for filter snmp, lrc = -1
Feature:
Feature Field Escalation Function:
Function SNMP
Probability:
Probability High
Found in Release
Release:
ase FOS6.2.1 Service Request ID:
ID 405179
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000273580 Technical Severity:
Severity Medium
Summary:
Summary "lscfg --show" on FS8-18 reports problem on port number higher than 15
Symptom:
Symptom “ASIC not ready” errors after the blade removal and insertion of the FS8-18 Blade. Obaserve
FW-5002 in internal raslog when this happens.
Feature:
Feature FC4-16IP Platform Services Function:
Function FC4-16IP Blade Driver
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000274458 Technical Severity:
Severity Medium
Summary:
Summary Handle command timeout for cvlm/cvlc commands and CAL call optimization to address
weblinker crash
Symptom:
Symptom Blade faulted and weblinker crash when blade is stressed with heavy IO and constant stats
gathering
Feature:
Feature Data Security Function:
Function Disk Encryption
Probability:
Probability Medium
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000274882 Technical Severity:
Severity Medium
Summary:
Summary DCX doesn't output FW-1003/FW-1004 after hafailover/reboot if user sets fwsettocustom.
Symptom:
Symptom DCX could not output FW-1003/FW-1004 after hafailover/reboot if user sets the
fwsettocustom. This cause customer does not get notified on temperature etc event change
when it's over threshold value.
Feature:
Feature Field Escalation Function:
Function High Availability
Probability:
Probability High
Found in Release:
Release FOS6.2.2 Service Request ID:
ID 413945
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000275158 Technical Severity:
Severity Medium
Summary:
Summary Observed CALD panic in 256 ports switch after stress test switchdisable/switchenable
Symptom:
Symptom Switch panic observed when large number of F_Port has top talkers installed on the switch.
Feature:
Feature Mgmt Embedded - CAL Function:
Function Other
Probability:
Probability Medium
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000275255 Technical Severity:
Severity Medium
Summary:
Summary ssmd is crashing when certain cli is executed
Symptom:
Symptom clearing counters of acl's whose name starts with numeric value or just a numeric value will
cause crashing of ssm. For example: sw0# clear counters access-list mac 2acl_std or
sw0#clear counters access-list mac 10 Now ssm will get crashed.
Feature:
Feature CEE-SYSTEM SERVICES Function:
Function ACL
Probability:
Probability Medium
Found in Release:
Release FOS6.3.1_cee
Defect ID:
ID DEFECT000277671 Technical Severity:
Severity Medium
Summary:
Summary FW-1434 message when systemverification or portloopbacktest run on DCX
Symptom:
Symptom During diag test, switch report: 2009/12/02-15:02:50, [FW-1434], 5, SLOT 7 | FID 128,
WARNING, sw0, Switch status change contributing factor Blade: 1 blade failures (MARGINAL).
Once diag test complete, Fabric Watch reports switch is healthy.
Feature:
Feature Field Escalation Function:
Function Management Services
Probability:
Probability High
Found in Release:
Release FOS6.2.2 Service Request ID:
ID 413595
Where Else Fixed: FOS6.2.2 a
Defect ID:
ID DEFECT000278326 Technical Severity:
Severity Medium
Summary:
Summary DCX 8-Link ICL license only brings up 4 Links when connected to DCX-4S
Symptom:
Symptom Based on the way the physical connections are made on an ICL between a DCX and DCX-4S,
only half of the expected E-Ports (links) are coming online when a 8-Link ICL license is installed.
Feature:
eature FC Services Function:
Function Fabric
Probability:
Probability Medium
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000274646 Technical Severity:
Severity High
Summary:
Summary Brocade 8000 installed with FOS v6.3.0 through v6.3.0c, v6.3.1 and v6.3.1a panics doing
firmwaredownload.
Symptom:
Symptom Switch panic reported during firmware download. This only applies to Brocade 8000s factory
installed with FOS v6.3.0 through v6.3.0c, v6.3.1 and v6.3.1a.
Workaround:
Workaround Before upgrading from FOS v6.3.0 through v6.3.0c, v6.3.1 or v6.3.1a, check if /dev/altera is
present in secondary partition. If not present, copy it from primary partition via "cp
/dev/altera /mnt/dev/altera".
Feature:
Feature CEE-Infrastructure Function:
Function Zues Driver
Probability:
Probability High
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000283637 Technical Severity:
Severity High
Summary:
Summary During hot code load, HA recover time is very long.
Symptom:
Symptom Under race condition, when extensive writing to compact flash happens during hafailover,
observe long HA recover time on switch. This could cause link reset or frame drop when
connecting switch did not see credit being returned in time. This is observed more often in, but
not limited to, VF environment and connecting switch is operating under single virtual channel
credit model. It applies to both director and switch platforms.
Feature:
Feature Infrastructure Function:
Function PDM/PortCfg
Probability:
Probability Low
Found in Release:
Release FOS6.4.0
Defect ID:
ID DEFECT000286104 Technical Severity:
Severity High
Summary:
Summary Ports on the FC8-48 become persistently disabled after upgrading from FOS v6.2.x to FOS
v6.3.x.
Symptom:
Symptom After upgrading from FOS v6.2.x to FOS v6.3.x on systems with FC8-48 blades installed, VF
disabled and fmsmode enabled, all ports on the FC8-48 blades to become persistently disabled
without warning.
Workaround:
Workaround Manually re-enable ports, no other viable workaround at this time
Feature:
Feature Field Escalation Function:
Function FICON
Probability:
Probability High
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 423415
Defect ID:
ID DEFECT000289029 Technical Severity:
Severity High
Summary:
Summary DCX reboots continuously as Access Gateway config file is corrupt on FOS v6.3.0x
Symptom:
Symptom Under very rare condition, access gateway configuration files are corrupted and caused switch
bring up to timeout. Switch is reboot repeatedly by HA manager in an attempt to recover switch
with raslog: [HAM-1007]…, Need to reboot the system for recovery, reason: System bring up
timed out, … [HAM-1008]…,Rebooting the system for recovery - auto-reboot is enabled, This only
applies to FOS v6.3.0x and non-AG platforms. It does not apply to FOS v6.3.1 and later, or Pre-
FOSv6.3.0 releases.
Workaround
Workaround:
rkaround Follow the procedure show below to remove the corrupted files and upgrade to a version of
FOS that incorporates a fix for this problem
1. Execute the following commands to stop the recover reboot process on both CPs
a. touch /etc/fabos/config/no_reboot_recover
b. touch /mnt/etc/fabos/config/no_reboot_recover
2. Execute the following commands remove the corrupted AG files on both CPs
a. rm /etc/fabos/persistent_NPIV_config
b. rm /mnt/etc/fabos/persistent_NPIV_config
3. Reboot the switch
4. After the switch comes back up use the commands list below to remove the recover file again
on both CPs.
a. rm /etc/fabos/config/no_reboot_recover
b. rm /mnt/etc/fabos/config/no_reboot_recover
5. Upgrade the switch to FOS v6.3.0d or v6.3.1 and later.
Feature:
Feature Access Gateway Services Function
Function:
tion Daemon
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270261 Technical Severity:
Severity Medium
Summary:
Summary CP/switch fails to boot on DCX, DCX-4s and Brocade 5300.
Symptom:
Symptom The CP or switch fails to reboot, boot up on power up or fails during hafailover. The following CF
access error message, "HDA: drive not ready" is usually seen on the console when this occurs.
Feature:
Feature OS Services Function:
Function Linux Kernal
Probability:
Probability Low
Found in Release:
Release FOS6.2.0
Where Else Fixed: FOS6.2.2 b, FOS6.3.1 a
Defect ID:
ID DEFECT000284472 Technical Severity:
Severity Medium
Summary:
Summary State Change Registration (SCR) value is not properly registered in the name server.
Symptom:
Symptom When performing a firmware upgrade from Fabric OS v6.2.x to Fabric OS v6.3.0 through v6.3.0c
or v6.3.1 the SCR registration inside the Name Server is lost at the time of upgrade. As a result,
devices attached to the upgraded switch are not notified of changes to other devices in common
zones or other changes to the zoning configuration. This impacts all platforms with FC ports in
both FICON and non-FICON environment.
Workaround:
Workaround There are no non-disruptive workarounds to correct this problem. The customers may choose
to perform the following disruptive action. Perform a portdisable/portenable on all the
affected ports within the zone. However, because of its disruptive nature, Brocade does not
recommend this procedure.
Feature:
Feature Field Escalation Function:
Function Fabric Services
Probability:
Probability High
Found in Release:
Release FOS6.3.0 Service Request
Request ID:
ID 421925
Where Else Fixed: FOS6.3.1 a
Defect ID:
ID DEFECT000265272 Technical Severity:
Severity Critical
Summary:
Summary Brocade 48000 with FR4-18i cannot see new device across LSAN after upgrade from FOS v5.x
non-disruptively all the way to FOS v6.2.x.
Symptom:
Symptom Customer unable to bring new devices on line, bounce host port causes path lose between host
and target. internal raslog has: [BL-5238], , Pinball Consistency check failure: error = -2, rsc = 1,
data1 = -1, data2 = 11, OID:0x43310881, marathon_fcr.c, line: 2296, comp:emd,
ltime:2009/09/17-18:47:02:676934; This only applies 4G routers and problem only shows
after upgrade to FOS v6.2.x.
Feature:
Feature Field Escalation Function:
Function ASIC Driver
Probability:
Probability High
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 402497
Where Else Fixed:
Fixed FOS6.2.2
Defect ID:
ID DEFECT000270541 Technical Severity:
Severity Critical
Summary:
Summary On DCX, FCR fails to route traffic on 8G EX ports after code upgrade from FOS v6.1 to FOS v6.2,
followed by hafailover and ports activities
Symptom:
Symptom DCX running FOS v6.1 with 8G EX ports (Integrated routing, IR) as pre-condition, upgrade to
FOSv6.2 based code, if there is additional hafailover, then add new device, bounce device ports
could trigger route problem, cause host cannot see device.
Feature:
Feature Field Escalation Function:
Function FCR
Probability:
Probability High
Found in Release
Release: FOS6.2.0 Service Request ID:
ID 409197
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000269315 Technical Severity:
Severity High
Summary:
Summary Switch panic occurred when 3rd party management application performed repeat FCP LUN
emulation queries.
Symptom:
Symptom When a 3rd party device gives a bad response to a FCP LUN request, or does not respond at all,
FCPD will retry query and stuck the thread. Any new FCP LUN request that comes in from
management application will spawn a new thread to handle it. Eventually, FCPD spawns up to
the maximum number of allowed threads and the switch panics.
Feature:
Feature Field Escalation Function:
Function Fabric Services
Probability:
Probability Low
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 407027
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000270712 Technical Severity:
Severity High
Summary:
Summary Host failed to discover tapes due to a VI/VT database mismatch between the switches that are
part of the same Encryption Group
Symptom:
Symptom Host will not able to discovery Tape devices that are part of the same EG
Workaround:
Workaround Issue "cryptocfg --commit" again to sync up the VT/VI database across nodes in the EG.
Feature:
Feature Data Security Function:
Function Tape Encryption
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000271290 Technical Severity:
Severity High
Summary:
Summary Brocade 5424 - SERDES settings do not get push correctly on v6.3.0x
Symptom:
Symptom Incorrect SERDES settings used.
Feature:
Feature Embedded Platform Services Function:
Function Superhawk2
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000273043 Technical Severity
Severity:
erity High
Summary:
Summary When running FCoE feature related scripts over multiple SMIA clients the Common Access
Library Daemon (CALD) detects a memory increase on the Brocade 8000 switch. Other FOS
based products do not exhibit the same behavior when running the same scripts.
Symptom:
Symptom 34MB memory increase seen in Common Access Library Daemon (CALD) when running 10 SMIA
clients over FCoE.
Feature:
Feature CEE-MANAGEABILITY Function:
Function CAL INTERFACE
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000267497 Technical Severity:
Severity Medium
Summary:
Summary When CP restarts DPC-0, sassvrd sees ECONNRESET on DPC1 connection and BP freezes for 10
seconds
Symptom:
Symptom On one DPC failure, second DPC on the same switch also experience disruption.
Feature:
Feature FA4-18 Platform Services Function:
Function MISC
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000268872 Technical Severity:
Severity Medium
Summary:
Summary The command fcoe loginshow displays unexpected values when a third party CNA is moved
between switches.
Symptom:
Symptom Unexpected values are seen in response to the loginshow command.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269956 Technical Severity:
Severity Medium
Summary:
Summary OPT 322202 - IPC failure message displayed on one of the nodes when using the cryptocfg --
show -groupmember -all command
Symptom:
Symptom Customer will not be able to use "cryptocfg --show -groupmember -all" CLI to know the health of
the EG, EEs in the EG when this very remote corner case is hit. However there is no impact to
health of EG or EE states in the EG and no impact to any datapath. The health of EG can be
determined alternately by issuing "cryptocfg --show -groupcfg" and "cryptocfg --show -localEE"
CLIs on each of the Node in the EG
Workaround
Workaround:
und Issue "cryptocfg --show -groupcfg" and "cryptocfg --show -localEE" commands instead to know
the health of EG
Feature:
Feature Data Security Function:
Function Tape Encryption
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270309 Technical Severity
Severity:
ity Medium
Summary:
Summary Running FOS commands give error: shmInit: shmget failed: No space left on device
Symptom:
Symptom Unable to execute FOS commands on default switch after performing multiple cfgenable with TI
zones
Feature:
Feature FC Services Function:
Function Name Server
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000270368 Technical Severity:
Severity Medium
Summary:
Summary 1GB FCIP tunnel with 2 rate limited circuits is unable to move full I/O workload to remaining
circuit when 1 circuit fails.
Symptom:
Symptom In a multi circuit FCIP tunnel configuration circuit failover over 1G tunnels may not failover to
other available circuits.
Feature:
Feature FCIP Function:
Function FCIP Performance
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000270562 Technical Severity:
Severity Medium
Summary:
Summary FICON XRC Emulation - READTRACK_STATUS_ACCEPT flag cleared on Tunnel Down and Selective
Reset causes Abort Sequences later
Symptom:
Symptom Slow read track performance when XRC emulation is enabled, MVS IO errors are generated when
an invalid selective reset frame is sent to the controller.
Workaround:
Workaround Disable FICON XRC Emulation
Feature:
Feature FCIP Function:
Function FCIP Performance
Probability:
Probability High
Found in Release:
Release FOS6.2.0
Defect ID:
ID DEFECT000271177 Technical Severity
Severity: Medium
Summary:
Summary Additional information of the EE status in the current command that displays the overall status
of the EG, nodes and RKM(cryptocfg --show --groupcfg)
Symptom:
Symptom Customer will have to invoke "cryptocfg --show -groupcfg", "cryptocfg --show -groupmember -all"
or "cryptocfg --show -localEE" on all nodes to know the overall state of EG including EE state
across EG. There is no one place where Customer will get the EE state across EG in the same
command which provides the EG health
Feature:
Feature Data Security Function:
Function Infrastructure
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000271220 Technical Severity:
Severity Medium
Summary:
Summary Unexpected termination of raslogd triggered switch panic or hafailover.
Symptom:
Symptom When auditing is on for security class, a race condition in raslogd triggered switch to panic.
Workaround:
Workaround disable auditing via: Auditcfg --disable
Feature:
Feature Field Escalation Function:
Function RAS Logging / Tracing
Probability:
Probability Low
Found in Release:
Release FOS6.1.0 Service Request ID:
ID 409971
Defect ID:
ID DEFECT000272183 Technical Severity:
Severity Medium
Summary:
Summary IFCCs encountered when processing Read Channel Extender Capabilities with XRC Emulation
Symptom:
Symptom IFCCs when IPLing systems with SDM LPARs
Workaround:
Workaround Disable FICON XRC Emulation
Feature
Feature:
re FCIP Function:
Function FCIP I/O
Probability:
Probability Low
Found in Release:
Release FOS6.2.0
Defect ID:
ID DEFECT000272203 Technical Severity:
Severity Medium
Summary:
Summary RNID frame type field from the host is corrupted internally when the host is connected over FCIP.
Symptom:
Symptom Corrupted RNID request is received from the host and rejected. As a result, the switch is unable
to get FICON CHPID online to VSM (Virtual Tape Subsystem) over an emulated or non-emulated
VE tunnel. E-Port between switches functions correctly.
Workaround:
Workaround Disable FICON Tape Emulation
Feature:
Feature FCIP Function:
Function FCIP Port
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000272842 Technical Severity:
Severity Medium
Summary:
Summary Switch does not broadcast Unsolicited FIP Discovery Advertisements
Symptom:
Symptom If the CNA expects UAs from the FCF even if the solicited advertisement had the “D” bit set, it will
logout of the FCF after about 20 seconds.( Tomcat does not logout, Emulex logs out)
Feature:
Feature CEE-FCOE Function:
Function FCOE Daemon
Probability:
Probability Low
Found in Release
Release:
ease FOS6.3.1
Defect ID:
ID DEFECT000274208 Technical Severity:
Severity Medium
Summary:
Summary After upgrade to FOS v6.2.x, 4G AP blade observes credit problem on virtual channel 0
Symptom:
Symptom Customer after upgrade to FOS v6.2.x, experience frame drop on SAS, FCIP, FC FastWrite and
observe host cannot see target, FCIP tunnel do not come up problems.
Workaround:
Workaround Port bounce, POR of Brocade 7600. If it is 48K with an FA4-18 blade then port bounce,
slotpower off/on of FA4-18 or POR.
Feature:
Feature Field Escalation Function:
Function ASIC Driver
Probability:
Probability High
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 412817
Defect ID:
ID DEFECT000274953 Technical Severity:
Severity Medium
Summary:
Summary Rekey sessions supposed to be pending cannot be persisted when the EE hosting node fails
over
Symptom:
Symptom Customer will have to restart the rekey individually for those LUNs for which the rekey sessions
could not be automatically started if HA Cluster failover happens before keys were successfully
created for all LUNs under rekey.
Workaround:
Workaround Start the rekey sessions for LUNs on individual basis
Feature:
Feature Data Security Function:
Function Re-key
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000275108 Technical Severity:
Severity Medium
Summary:
Summary Restore Master Key from recovery cards does not put EE Online when all EEs in the EG were
zeroized
Symptom:
Symptom When a customer zeroizes all EEs in the EG and restores the Master Key from recovery smart
cards will not put EE online
Workaround:
Workaround Restore MK the second time.
Feature:
Feature Data Security Function:
Function Security Processor
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect
Defect ID:
ID DEFECT000259050 Technical Severity:
Severity Critical
Summary:
Summary FICON emulation failing.
Symptom:
Symptom MVS IOS444I error messages when trying to vary paths online to extended DASD devices.
Workaround:
Workaround Disable FICON XRC Emulation
Feature:
Feature Field Escalation Function
Function:
tion FCIP
Probability:
Probability Low
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 389217
Where Else Fixed: FOS6.3.0
Defect ID:
ID DEFECT000261125 Technical Severity:
Severity High
Summary:
Summary In a large fabric with 50+ switches, firmware download (HCL) on Brocade DCX failed on the
standby CP.
Symptom:
Symptom In a large fabric with 50+ switches, non-disruptive Firmwaredownload may fail on a standby CP
of a DCX switch.
Workaround:
Workaround Run firmwaredownload again.
Feature:
Feature FIRMWARE DOWNLOAD Function:
Function Firmware Download
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000261231 Technical Severity:
Severity High
Summary:
Summary RASLOG flood occurs with internal RASLOG with following weblinkerfcg message on multiple
switches in fabric: "weblinkerfcg:1024 attempts to send message type(26) to invalid
dest(IPSIPC:1024/0), comm.c, line: 453, comp:weblinker, ltime:2009/07/28-11:39:
Symptom:
Symptom Due to excessive internal messages from one of the applications, other important RASLOG
messages may be lost from the limited log space on each switch.
Feature:
Feature FCIP Function:
Function FCIP CP
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000261418 Technical Severity:
Severity High
Summary:
Summary Panic Reboot on Brocade DCX after using fwshow command.
Symptom:
Symptom Switch reboot occurs after running the command "fwshow --disable --port".
Feature:
Feature Field Escalation Function:
Function Management Services
Probability:
Probability High
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 394347
Where Else Fixed: FOS6.2.2, FOS6.2.1 b
Defect ID:
ID DEFECT000261593 Technical Severity:
Severity High
Summary:
Summary Switch went to faulty state after which supportsave takes very long time to complete
Symptom:
Symptom Brocade 7600 becomes faulty and supportSave takes very long time.
Feature:
Feature FA4-18 Platform Services Function:
Function ASIC Driver
Probability:
Probability High
Found in Release:
Release FOS6.2.1
Defect ID:
ID DEFECT000261797 Technical Severity:
Severity High
Summary:
Summary Brocade SMI failed to discover all switches over EX port
Symptom:
Symptom After hafailover, application fails to discover some switches over EX port due to, SMI reports
"LOGIN FAILED" after GPL2 query targeted to translate domain is rejected.
Feature:
Feature Field Escalation Function:
Function FCR
Probability:
Probability Medium
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 392369
Where Else Fixed: FOS6.2.2, FOS6.2.1 a
Defect ID:
ID DEFECT000261946 Technical Severity:
Severity High
Summary:
Summary Upgrade from 6.2.0g to 6.3.0 ldap certificates are missing
Symptom:
Symptom Customer may not be able to log into switch when using LDAP authentication.
Workaround:
Workaround Log into serial console and reimport the ldap certificate(s). The degree to which the user will
be locked out would depend on how the LDAP environment was setup.
Feature:
Feature FOS Security Function:
Function LDAP
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000263464 Technical Severity
Severity:
rity High
Summary:
Summary Device connectivity lost when zone enabled on Brocade 7800
Symptom:
Symptom Lost device connectivity
Feature:
Feature Striker/Spike Platform Services Function:
Function Routing
Probability:
Probability High
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000264398 Technical
Technical Severity:
Severity High
Summary:
Summary Common Access Layer Daemon (CALD) panics due to segmentation fault
Symptom:
Symptom A fabric that contains switches running firmware older then FOS v5.2.x could send an internal
query to directors that was not properly set up to handle switches with more than 256 ports.
This query can result in the switch with greater than 256 ports.
Feature:
Feature Field Escalation Function:
Function Management Embedded
Probability:
Probability Medium
Found in Release:
Release FOS6.2.0
Where Else Fixed: FOS6.2.2, FOS6.2.1 b
Defect ID:
ID DEFECT000265414 Technical Severity:
Severity High
Summary:
Summary Kernel panic when performing POR on DCX
Symptom:
Symptom Switch crash and reboot.
Feature:
Feature 8G ASIC Driver Function:
Function C2 ASIC driver
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265511 Technical Severity:
Severity High
Summary:
Summary Brocade 7800 DP crashed after connecting 10G ports to Anue impairment box
Symptom:
Symptom Tunnel does not come up.
Feature:
Feature FCIP Function:
Function FCP TCP/IP Stack
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265695 Technical Severity:
Severity High
Summary:
Summary Strict fabric wide policy conflict occurs after HA failover
Symptom:
Symptom Switch segmented out of fabric.
Feature:
Feature FC Services Function:
Function ESS
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265697 Technical Severity:
Severity High
Summary:
Summary Block port is not being displayed in IPL file after host blocks port in-band
Symptom:
Symptom IPL file is not updated.
Feature:
Feature FICON Function:
Function Ficud
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265834 Technical Severity:
Severity High
Summary:
Summary RLIR in IM2 fabric is using domain with offset stripped
Symptom:
Symptom RLIR or DRLIR generated by FOS did not contain domain offset of 0x60 in PID & TAG fields when
running IM2 mode.
Feature:
Feature FICON Function:
Function MS-FICON
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000267476 Technical Severity:
Severity High
Summary:
Summary 7800 panic during overnight workload
Symptom:
Symptom 7800 switch crashed and FCIP I/O stopped.
Feature:
Feature Striker/Spike Platform Services Function:
Function Blade Driver
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000267481 Technical Severity:
Severity High
Summary:
Summary Internal FICON error when doing port swap.
Symptom:
Symptom Internal FICON error
Feature:
Feature FICON Function:
Function Other
Probability:
Probability Low
Found
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269111 Technical Severity:
Severity High
Summary:
Summary No NPIV devices (including AG) can log into ports of the 7800 when port is changed from EX port
to NPIV after non-disruptive upgrade
Symptom:
Symptom NPIV ports cannot login.
Feature:
Feature Striker/Spike Platform Services Function:
Function Spike Platform Module
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269604 Technical Severity:
Severity High
Summary:
Summary FICON Emulation not handling Abort Sequence correctly and causing DSO FICON CRC Errors
Symptom:
Symptom IO Errors during XRC RRS processing and eventual suspend of the session that encounters the
error.
Workaround:
Workaround Disable FICON XRC Emulation
Feature:
Feature FCIP Function:
Function FCIP I/O
Probability:
Probability Low
Found in Release:
Release FOS6.2.0
Defect
Defect ID:
ID DEFECT000246346 Technical Severity:
Severity Medium
Summary:
Summary During stress testing, after multiple VLAN configuration changes, logins from the CNA are
unsuccessful.
Symptom:
Symptom Multiple VLAN configuration changes result in FLOGI being ignored.
Feature:
Feature CEE-FCOE Function:
Function FCOE Daemon
Probability:
Probability Medium
Found in Release:
Release FOS6.1.3_cee
Defect ID:
ID DEFECT000246883 Technical Severity:
Severity Medium
Summary:
Summary Pre-FIP LOGO with Invalid WWNN (non-existent fabric device) is accepted
Symptom:
Symptom Incorrect device logout.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability High
Found in Release:
Release FOS6.1.3_cee
Defect ID:
ID DEFECT000247639 Technical Severity:
Severity Medium
Summary:
Summary Switch responds to FIP FLOGI when SP bit is on and FP bit is off
Symptom:
Symptom Incorrect FIP FLOGI response sent by switch.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability Low
Found in Release:
Release FOS6.1.3_cee
Defect ID:
ID DEFECT000248213 Technical Severity:
Severity Medium
Summary:
Summary FIP FLOGI accepted when host supports only spma
Symptom:
Symptom Incorrect FIP FLOGI request is accepted rather than rejected.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability Low
Found in Release:
Release FOS6.1.3_cee
Defect ID:
ID DEFECT000255703 Technical Severity:
Severity Medium
Summary:
Summary Brocade 8000 floods FCP traffic on two ports to CNAs
Symptom:
Symptom Brocade 8000 sends FCP traffic to the wrong CNA.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability High
Found in Release:
Release FOS6.1.2_cee Service Request ID:
ID 384593
Defect ID:
ID DEFECT000257211 Technical Severity:
Severity Medium
Summary:
Summary Weblinker.fcg terminates several times during third party host scan.
Symptom:
Symptom When third party host scan was run, http daemon died and restart several times may trigger
temporary management service interruption.
Feature:
Feature Field Escalation Function:
Function Web Management
Probability:
Probability Medium
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 386535
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000258696 Technical Severity:
Severity Medium
Summary:
Summary Switch responds with advertisement to solicitation with SP bit on
Symptom:
Symptom Customer will see a response to a solicitation with SP bit on.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000259855 Technical Severity:
Severity Medium
Summary:
Summary When FCoE max login has been reached, need to change debug log to customer visible RASLOG,
to indicate FCoE login has been reached.
Symptom:
Symptom Customer may not know the reason for login reject in case FCoE login limit has been reached.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability Medium
Found
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000261132 Technical Severity:
Severity Medium
Summary:
Summary In a large fabric with more than 56 switches, edge Brocade DCX panics due to termination of
msd during fabric reconfiguration.
Symptom:
Symptom While doing switchdisable; agshow; switchenable loop on a large fabric with AG device, switch
panics.
Feature:
Feature Fabric Infrastructure Function:
Function MANAGEMENT SERVER
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Where Else Fixed: FOS6.2.2, FOS6.2.1 a
Defect ID:
ID DEFECT000261754 Technical
Technical Severity:
Severity Medium
Summary:
Summary Observing ffdc data files during continuous interface flap
Symptom:
Symptom Interface flapping/ bad cable shows to many ras log messages
Workaround:
Workaround Shut down the port and replace the faulty cable and enable the port
Feature:
Feature CEE-Infrastructure Function:
Function ANVIL DRIVER
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000263948 Technical Severity:
Severity Medium
Summary:
Summary FIP: when CNA send FIP ver=0, switch should not validate MAC descriptor field for backwards
compatibility
Symptom:
Symptom Switch rejects login due to backward incompatibility.
Feature:
Feature CEE-FCOE Function:
Function FCOE DRIVER
Probability:
Probability Medium
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000264578 Technical Severity:
Severity Medium
Summary:
Summary Supportsave did not remove ffdc files. Continued to get ffdc files warning
Symptom:
Symptom Supportsave command did not clear FFDC files. FFDC file warning message persisted until a
second support save was taken.
Feature:
Feature RAS Function:
Function FFDC/Supportsave
Probability:
Probability Low
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 399193
Where Else Fixed: FOS6.2.2
Defect ID:
ID DEFECT000265225 Technical Severity:
Severity Medium
Summary:
Summary Unsupported SFP amber flashing state is cleared by plugging an optical cable into the SFP.
Actual port status is not affected.
Symptom:
Symptom An unsupported SFP installed in an FX8-24 can have the amber LED extinguished if a cable is
plugged into the SFP. The actual port status is not changed but the visible indication of a fault
(flashing amber) is extinguished.
Feature:
Feature Striker/Spike Platform Services Function:
Function Spike Platform Module
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265396 Technical Severity:
Severity Medium
Summary:
Summary Web Tools shows iodset off but CLI shows it is enabled.
Symptom:
Symptom Incorrect IOD configuration state is displayed through Web Tools.
Workaround:
Workaround Using CLI to view the configured IOD state when IOD is enabled with Lossless DLS
Feature:
Feature WebMgmt Function:
Function WT Platform Support
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265398 Technical Severity:
Severity Medium
Summary:
Summary Brocade Encryption Switch went faulty during rekey operation
Symptom:
Symptom Brocade Encryption Switch faulted, rekey failed and required a power cycle.
Feature:
Feature Data Security Function:
Function Re-key
Probability:
Probability Low
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 401091
Defect ID:
ID DEFECT000265399 Technical Severity:
Severity Medium
Summary:
Summary BES did not rejoin Encryption Group after reboot
Symptom:
Symptom Encryption switch cannot rejoin Encryption Group resulting in split.
Feature
Feature:
re Data Security Function:
Function Infrastructure
Probability:
Probability Low
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 401091
Defect ID:
ID DEFECT000265530 Technical Severity:
Severity Medium
Summary:
Summary I/O traffic get flooded in to port 16
Symptom:
Symptom Incorrect port showing I/O traffic.
Feature:
Feature CEE-Infrastructure Function:
Function ANVIL DRIVER
Probability:
Probability Medium
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000265563 Technical Severity:
Severity Medium
Summary:
Summary Web Tools launch fails with license error/doget failed from DCFM
Symptom:
Symptom While launching the Web tools, in some corner cases HTTP request for authentication may result
in failure. A subsequent Web tools session clears this issue.
Feature:
Feature WebMgmt Function:
Function Webstart
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265753 Technical Severity:
Severity Medium
Summary:
Summary Improve BES error handling when the backend tape target is not responsive
Symptom:
Symptom Host cannot recover if backend tape target become not responsive during BES initiated
commands.
Feature:
Feature Data Security Function:
Function Tape Encryption
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000267358 Technical Severity:
Severity Medium
Summary:
Summary sfpshow: smart data is not refreshed by polling loop for GE type ports
Symptom:
Symptom Newer smart data (for GE type ports) such as SFP temperature and power are not updated by
the automatic polling loop that occurs roughly every 5 minutes.
Feature:
Feature Striker/Spike Platform Services Function:
Function Spike Platform Module
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect
Defect ID:
ID DEFECT000267415 Technical Severity:
Severity Medium
Summary:
Summary Supportsave does not capture all the FID with index greater than 3
Symptom:
Symptom Information for FID with index greater than 3 is not captured in supportSave.
Feature:
Feature VF Infrastructure Function:
Function LS Config CLI
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000268955 Technical Severity:
Severity Medium
Summary:
Summary links on the AG (port 19) went into a disabled state with the reason: "NPIV not supported by
Fabric port". However, the edge switch port (7/27) had NPIV enabled.
Symptom:
Symptom port on AG switch become disabled.
Feature:
Feature Access Gateway Services Function:
Function Daemon
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269138 Technical Severity:
Severity Medium
Summary:
Summary In the Element Manager, under switch admin, we selected FCoE Login and got an error message
of "FCoE Login Management is disabled in the switch; make sure you enable it to view the
chassis".
Symptom:
Symptom "FCoE Login" tab name causes confusion. It needs to be changed to "FCoE Login Group".
Feature:
Feature WebMgmt Function:
Function WT Platform Support
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000269286 Technical Severity:
Severity Medium
Summary:
Summary portdisable xge0 did not actually disable the port although RAS log and switchshow show it is
disabled, the FCIP tunnels are still up and running.
Symptom:
Symptom xge0 port on FX8-24 is not properly disabled when running portdisable CLI.
Feature:
Feature Striker/Spike Platform Services Function:
Function BFOS
Probability:
Probability Medium
Found in Release
Release:
se FOS6.3.1
Defect ID:
ID DEFECT000263579 Technical Severity
Severity:
verity Critical
Summary:
Summary Switch panic occurred when management application performed repeat FCP LUN emulation
queries through SMI interface or application polling a switch that had password changed
multiple times.
Symptom:
Symptom Switch panic is experienced. Switch console logs Out of Memory kill.
Workaround:
Workaround Disable SMI agents.
Feature:
Feature Field Escalation Function:
Function Panic / OOM
Probability:
Probability High
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 399773
Defect ID:
ID DEFECT000247761 Technical Severity:
Severity High
Summary
Summary:
ary Sysshutdown on Brocade 5480 may cause panic and reboots
Symptom:
Symptom Switch panic during sysshutdown
Workaround:
Workaround Use CLI "shutdown" command.
Feature:
Feature Embedded Platform Services Function:
Function Bulova
Probability:
Probability High
Found in Release:
Release FOS6.2.0 Service Request
Request ID:
ID 375389
Defect ID:
ID DEFECT000254576 Technical Severity:
Severity High
Summary:
Summary Brocade FR4-18i heartbeat dead causes reboot.
Symptom:
Symptom Processor on FR4-18i blade reboots while traffic is running over FCIP links. May cause CP
failover to take place, only traffic on the FR4-18i blade is disrupted.
Feature:
Feature Field Escalation Function:
Function FCIP Flipper/ASIC
Probability:
Probability Low
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 374539
Defect ID:
ID DEFECT000259327 Technical Severity:
Severity High
Summary:
Summary After changing domain offset followed by 'hafailover'-"Unknown LSR type" messages started
scrolling continuously on console log for Brocade DCX-4S, DCX and 48000 switches running in
Interopmode2.
Symptom:
Symptom After changing the domain offset, followed by 'hafailover' on CP1, CP0 immediately started
posting "Unknown LSR type" messages continuously on console log.
Workaround:
Workaround Run hafailover to failover to other CP.
Feature:
Feature FC Services Function:
Function FSPF
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000262164 Technical Severity:
Severity High
Summary:
Summary Under heavy traffic on 10G tunnel, continuous tunnel modification can cause traffic to halt
Symptom:
Symptom FCIP I/O traffic disruption during tunnel modification.
Workaround:
Workaround Slot power off/on the Brocade FX8-24 blade.
Feature
Feature:
ture FCIP Function:
Function Compression
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000262167 Technical Severity:
Severity High
Summary:
Summary I/O fails to across VE link when failover is done on a trunked EX port
Symptom:
Symptom Medusa I/O on a host connected to storage across a VE link times out and stops when
replication software I/O is running across the same link.
Feature:
Feature Striker/Spike Platform Services Function:
Function VEX
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000262247 Technical
Technical Severity:
Severity High
Summary:
Summary Zoning fails with "Transaction Commit failed. Loss of an E-port to a neighboring Mi10k in the
middle of a zone push operation caused the zoning request to fail. Zoning fails with
"Transaction Commit failed. Reason code 2 (26) - "Aca Was Rejected: Remote Switch Busy,
Retry in a few seconds"
Symptom: Zoning fails with "Transaction Commit failed. Reason code 2 (26) - "Aca Was Rejected: Remote
Switch Busy, Retry in a few seconds"
Workaround:
Workaround FC Services
Feature:
Feature Zoning Function
Function: Low
Probability:
Probability 396077 Risk of Fix:
Fix (Not Checked)
Found in Release:
Release v6.2.0d Service Request ID:
ID FOS6.2.0
Publications
Defect ID:
ID DEFECT000262261 Technical Severity:
Severity High
Summary:
Summary Traffic cannot run across edge to edge topology when compression and FastWrite are enabled.
Symptom:
Symptom I/O traffic is unable to run.
Feature:
Feature FCIP Function:
Function FCIP I/O
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000262333 Technical Severity:
Severity High
Summary:
Summary SFP power supply values are not displayed correctly after doing a non-disruptive firmware
upgrade to FOS v6.2.1 or FOS v6.3.0
Symptom:
Symptom SFP voltage may show incorrect values
Workaround:
Workaround Execute the same command again to get the correct values.
Feature:
Feature 8G Platform Services Function:
Function FOS Kernel Drivers
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000262419 Technical Severity:
Severity High
Summary:
Summary Under impairment, network configuration with high compressible data may result in tunnel
bounce
Symptom:
Symptom FCIP tunnel may go up and down in an impairment network configuration with highly
compressible data I/O.
Workaround:
Workaround Tunnel will recover after going down.
Feature:
Feature FCIP Function:
Function FCP TCP/IP Stack
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000262516 Technical
Technical Severity:
Severity High
Summary:
Summary Tunnel did not come up due to configuration mismatch for tape pipelining, one side shows
"Write only" and other side shows "Write/Read"
Symptom:
Symptom VE tunnel configuration not coming up.
Feature:
Feature FCIP Function:
Function FCIP CLI
Probability
Probability:
ility Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000262891 Technical Severity:
Severity High
Summary:
Summary Ports go offline with link reset
Symptom:
Symptom High CPU load from external SAN management application such as doing supportsave from
Brocade DCFM is causing laser flt / link reset on port.
Feature:
Feature 4G ASIC Driver Function:
Function PORT
Probability:
Probability High
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 397469
Defect ID:
ID DEFECT000263397 Technical Severity:
Severity High
Summary:
Summary Brocade DCX running FOS v6.2.1 & M6140 running M-EOS v9.9.0 - Nameserver database
counts do not match for FOS and M-EOS switches in same fabric
Symptom:
Symptom Host cannot see device due to name server has no entries about the device. This happens
when there is a HBA capable of RHBA command and EOS (McDATA) switch in the same fabric.
Feature:
Feature FC Services Function:
Function FDMI
Probability:
Probability Medium
Found in Release:
Release FOS6.2.1 Service Request ID:
ID 398757
Defect ID:
ID DEFECT000264566 Technical Severity:
Severity High
Summary:
Summary Switch panic triggered by size-64 kernel message buffer being used up in virtual fabric with
logical ISL configured
Symptom:
Symptom Switch panic will be observed. Configuration requires VF with LISL configured. Prior to panic,
cat /proc/slabinfo as root will show a large number on size-64 block: slabinfo: size-64
7583624 7583624
Workaround:
Workaround Configure only DISLs between switches.
Feature:
Feature Logical Fabric Function:
Function Kernel Driver
Probability:
Probability High
Found in Release:
Release FOS6.2.1
Defect ID:
ID DEFECT000264640 Technical Severity:
Severity High
Summary:
Summary Configdownload does download some of the FCoE setting in FOS v6.3.0 that prevents factory
install
Symptom:
Symptom Prohibit factory install; missing entries are: fcoe.et.cfg:0x0, fcoe.fcmap:0x0
fcoe.fip.advintvl:0x0, fcoe.lg:0x0, fcoe.rcs.gen_number:0x0
Feature:
Feature CEE-FCOE Function:
Function FCOE PROTOCOL
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000264650 Technical Severity:
Severity High
Summary:
Summary History Buffer is updated according to Port Address rather than Port Number
Symptom:
Symptom Port reference provided to FICON host by the Director History Buffer for port parameter changes
is incorrect. In reading the switch configuration to gather updates for port parameter changes,
FICON host may reference a different port than the one that has changed state.
Feature:
Feature FICON Function:
unction Ficud
Probability:
Probability High
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000247754 Technical Severity:
Severity Medium
Summary:
Summary Brocade switch gets nsd panic in interopmode 3 when running FOS v6.2.
Symptom:
Symptom Customer may notice NSd panic
Feature:
Feature Field Escalation Function:
Function Fabric Services
Probability:
Probability High
Found in Release:
Release FOS6.2.0
Defect ID:
ID DEFECT000253083 Technical Severity:
Severity Medium
Summary:
Summary Transient detected error on internal link causes blade to be faulted
Symptom:
Symptom Port blade will be faulted with "reason=5"
Workaround:
Workaround Slotpoweroff and slotpoweron clears the fault
Feature:
Feature 8G ASIC Driver Function:
Function C2 ASIC driver
Probability:
Probability Medium
Found in Release:
Release FOS6.2.0 Service Request ID:
ID 378361
Defect ID:
ID DEFECT000260664 Technical Severity:
Severity Medium
Summary:
Summary After downgrading from FOS v6.3.0 to 6.2.0x, the bit count in fwconfigure – Eport –
StateChange is 63.
Symptom:
Symptom Once the user has a specific Eport StateChange configuration, if the command “fwconfigure –
eport – ST” is run after downgrading FOS v6.3.0 to 6.2.0x, the threshold is set at 63. This value
is not allowable in FOS v6.2.x since port fencing does not support State change in FOS v6.2.x.
Feature:
Feature Fabric Infrastructure Function:
Function Fabric Watch
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000261654 Technical Severity:
Severity Medium
Summary:
Summary During non-disruptive upgrade of FOS v6.3.0 on a Brocade5300 switch, "Software 'verify' error
seen on console
Symptom:
Symptom Software verify error when upgrading between two firmware versions.
Feature:
Feature Fabric Infrastructure Function:
Function Fabric Watch
Probability:
Probability Low
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000261978 Technical Severity:
Severity Medium
Summary:
Summary Retransmit and Out of order counters in portshow fciptunnel output do not show correct values.
Symptom:
Symptom Portshow fciptunnel dose not show correct counter value.
Feature:
Feature FCIP Function:
Function FCIP CLI
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000261982 Technical Severity:
Severity Medium
Summary:
Summary For some reason, if the first tunnel, the first circuit is not numbered 0, portshow fciptunnel all -c
will add the line with "16 0 unknwn Disable ----- 0s 0.00 0.00 0 0/0 0"
Symptom:
Symptom Incorrect tunnel/circuit number shown.
Feature:
Feature FCIP Function:
Function FCIP CLI
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000262329 Technical Severity:
Severity Medium
Summary:
Summary Configdefault does not delete the FCIP configurations even after chassis reboot.
Symptom:
Symptom FCIP configuration cannot be restored to the default setting via configdefault.
Feature:
Feature FCIP Function:
Function FCIP CP
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000263562 Technical Severity:
Severity Medium
Summary:
Summary Brocade switch drops frames received from host when the switch is unable to determine a valid
state for the back end tape
Symptom:
Symptom Frames from host to tape device are dropped by the switch.
Feature:
Feature Field Escalation Function:
Function Encryption
Probability:
Probability Medium
Found in Release:
Release FOS6.2.0
Defect ID:
ID DEFECT000263775 Technical Severity:
Severity Medium
Summary
Summary:
ary Switch View:In Striker face plate image, 10GE ports should be renamed as XGE ports.
Symptom:
Symptom Different naming for the same port may mislead the user.
Feature:
Feature WebMgmt Function:
Function Switch Explorer/Switch View
Probability:
Probability High
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000263805 Technical Severity:
Severity Medium
Summary:
Summary Ifname for xGIGE ports should show as in CLI.
Symptom:
Symptom The ifName value returned for xGIGE port does not match with the CLI output.
Feature:
Feature Mgmt Embedded - SNMP Function:
Function Other
Probability
Probability:
ability Medium
Found in Release:
Release FOS6.3.1
Defect ID:
ID DEFECT000264469 Technical Severity:
Severity Medium
Summary:
Summary Support of large ITL nexus in tape to handle multiplex/multistream environment
Symptom:
Symptom If the IT (target containers with initiator) is greater than 200, decreased performance is seen for
some containers.
Workaround:
Workaround Reduce the number of IT configuration (target containers with initiators) to 200.
Feature:
Feature OS Services Function:
Function Linux Kernal
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0 Service
Service Request ID:
ID 394589
Defect ID:
ID DEFECT000264871 Technical Severity:
Severity Medium
Summary:
Summary NS does not send subsequent PLOGI ACC following a sequence where NPIV device sends LOGO
before link down.
Symptom:
Symptom NPIV tape devices may not be seen by any of the hosts
Feature:
Feature FC Services Function:
Function Name Server
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0 Service Request ID:
ID 397897
Defect ID:
ID DEFECT000264971 Technical Severity:
Severity Medium
Summary:
Summary Unlike FC ports, GE ports will stick at No_Sync when you swap Invalid/Non-Brocade branded
SFP to Valid Brocade SFP.
Symptom:
Symptom GE ports will not come on line if unsupported SFP have been plugged in previously.
Workaround:
Workaround Portdisable and portenable after inserting supported SFP.
Feature:
Feature Striker/Spike Platform Services Function:
Function BFOS
Probability:
Probability Medium
Found in Release:
Release FOS6.3.0
Defect ID:
ID DEFECT000265149 Technical Severity:
Severity Medium
Summary:
Summary SFP hot-plug: Copper SFP can get into illegal state: Port State=Online and Port Phys=No_Light
and link led=OFF
Symptom:
Symptom Copper SFP on 7800 shows no LED light, while port is online and working.
Feature:
Feature Striker/Spike Platform Services Function:
Function Spike Platform Module
Probability:
Probability Low
Found in Release:
Release FOS6.3.0