Building Electrical
Building Electrical
FIXTURE SCHEDULE
MAIN PANEL SCHEDULE - 200AMPS 2" 1/2 C., 3/0 THHN, COPPER
SYMBOL MARK MANUF. FAMILY AND TYPE VOLTAGE WATTAGE COUNT COMMENTS
1 #4 COPPER THHN GROUND
Ckt # DESCRIPTION AMPS LOAD Ckt # DESCRIPTION AMPS LOAD R L-1 LITHONIA RECESSED CAN 6" 120 11 10
1 LOBBY #1 OUTLETS 20A 2.4kva 2 LOBBY #2 OUTLETS 20A 2.4kva ASTRONOMICAL TIMER, BATTERY
L-2 RAB LED EXTERIOR WALL PACK 120 23 7
BACKUP WITH PHOTO CELL SUB PANEL
3 PRINTER A OUTLETS 20A 2.4kva 4 PRINTER B OUTLETS 20A 2.4kva INVERTER
200 AMP
L-3 LITHONUA LED SHOP LIGHT 120 90 10 HIGH EFFICIENCTY LIGHTS 120/208
120/208
5 REFR OUTLET 20A 2.4kva 6 COFFEE OUTLETS 20A 2.4kva
1 1 PHASE
1 PHASE
L-4 LITHONIA EXIT COMBO 120 13 2 BATTERY BACKUP
(22KAIC #6 SOLID COPPER TO WATER
7 BREAK ROOM OUTLETS 20A 2.4kva 8 MICRO OUTLET 20A 2.4kva SCCR rating)
L-5 RAB EMERGANCY WALL PACK 120 0.7 4 BATTERY POWERED
9 LIGHTING A 20A 2.4kva 10 LIGHTING B 20A 2.4kva #6 SOLID COPER TO STEEL BUILDING
11 WAREHOUSE LIGHTING 20A 2.4kva 12 WAREHOUSE OUTLETS 20A 2.4kva PO Box 3188
Sonora, California 95370
13 WAREHOUSE OUTLETS 20A 2.4kva 14 WAREHOUSE OUTLETS 20A 2.4kva FINISH GRADE
tel: (209) 532-7169
15 WAREHOUSE OUTLETS 20A 2.4kva 16 BATHROOM GFCI 20A 2.4kva www.SierraNevadaEngineering.com
GROUND PER NEC
17 EF-2 20A 2.4kva 18 BATHROOM WATER HEATER 20A 2.4kva
2/0 COPPER TO UFER
19 EF-3 20A 2.4kva 20 BREAK ROOM WATER HEATER 20A 2.4kva GROUND PER NEC GROUND CONDUITS,
2/0 COPPER TO UFER WATER LINE AND BUILDING
21 22 #4 SOLID COPPER
GROUND CONDUITS,
HP-1 50A 20.76kva CONDUIT AND WIRE WATER LINE AND BUILDING
23 24 PER ELECTRICAL ENGINEER
TO CONNECT TO BATTERY
TOTAL LOAD = 68.76KVA
SINGLE LINE DIAGRAM
90'-0"
GFCI - GFCI -
WEATHERPROOF WEATHERPROOF
1
SOC
GFCI GFCI GFCI
200A PANEL
WITH ARC-FLASH WARNING
IN ACCORDANCE WITH CEC 110.16
GFCI
GFCI
GFCI
CONTROLLED RECEPTICALS
R R WITH OCCUPANCY SENSOR
1
R R
GFCI
R
GFCI - GFCI
WEATHERPROOF R
1
GFCI - Document Date:
SOC WEATHERPROOF
1 WITH EXTRA DUTY
6/21/24
SOC COVER
`Document Phase:
R
R DRAFT DRAWINGS
L-1
date remark
14'-0"
6/21/24 PLAN CHECK
1
CORRECTIONS
R R
1
1
SOC
SOC GFCI GFCI GFCI
1
GFCI -
WEATHERPROOF
CONTROLLED RECEPTICALS
WITH OCCUPANCY SENSOR
PER SECTION 130.5(d)
ELECTRICAL
E1.0
15'-6"
1 POWER 1'-0"
1/8"=1'-0"
EXHAUST FANS
VRF SPLIT HEAT PUMP/FAN COIL
MARK NAME-MODEL # SONES VOLTS PHASE MOCP CFM LOCATION REMARKS NOM.
MARK MODEL # VOLTS PHASE COOL HEAT CFM LOCATION
TONS
EF-1 FV-05-11VK2 0.3 120V 1 15 110 CEILING
HP-1 4MXS36RMVJU 3 230V 1 - - - GROUND
EF-2 FV-30NLF1 2 120V 1 15 340 IN LINE
FC-1 & FC-2 FTXS09LVJU 0.75 230V 1 9000 BTU 12000 BTU 420CFM WALL
EF-3 484X47 120V 1 4,479 IN LINE 1
1. EXHAUST VENTILATION
2022 CALIFORNIA MECHANICAL CODE SECTION 403.7
0.75CFM/SF = 4,050SF *0.75 = 3,040CFM MINIMUM PO Box 3188
Sonora, California 95370
tel: (209) 532-7169
90'-0" www.SierraNevadaEngineering.com
LOUVER
2022
FORCE ENERGY
FC-1
18'-4"
45'-0"
6" DIA
HP-1
31'-8"
EF-1
FC-2
EF-2
14'-0"
13'-0"
Document Date:
6/21/24
`Document Phase:
DRAFT DRAWINGS
date remark
2022
2022
15'-6"
1'-0"
MECHANICAL
1 MECHANICAL
1/4"=1'-0"
M1.0