Digicode riffa manual
Digicode riffa manual
1.Description
CC6 is a standalone access control, support card, pin, card+pin access way. It supports up to 2000
users , each user can possess one card and one pin.
It can directly drive Lock, Ring Bell, and also can connect with Exit Button.
There are 3 working mode with this device.1.Wiegand Reader, 2.Standalone for single door, 3.Anti-
passback for single door.
Besides, it also supports 1 Master code,2 Manager cards, providing users with easy operations and safety
reliability.
2.Features
3.Specification
4.Installation
Remove the back cover from the keypad using the supplied special screw driver
Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
Put the supplied rubber bungs to into the two holes
Fix the back cover firmly on the wall with 2 Self tapping screws
Thread the cable through the cable hole
Attach the keypad to the back cover.
5.Wiring
Stand Master
Menu Setting Remarks Functions
by Code
Red Red Red Orange
Flash
* Master 00 New master code# Repeat new master code # Factory Change the master code
code# (Note:Code length:6-8 digits) default:999999
01 Read Manager Add Card Default:Zone 1 Set Manager Add Card
02 Read Manager Delete Card Set Manager Delete Card
07 0000# Delete All Users
51 Master open Lock
Master
Standby Menu Setting Remarks Functions
Code
Red Red red orange
Flash
* Master 30 0-15# Default 0 To set facility code
code# 31 0# When device reset Wiegand reader
1# to factory Standalone for single door(Factory
default ,the setting default setting)
5# is still valid Anti-passback for single door
32 26-37# Default 26 To set Wiegand format
33 0-2# When device reset To set keypad transmission format
to factory
default ,the setting
is still valid
35 0# Default 0 Safe mode 0
1# Safe mode 1
2# Safe mode 2
Instruction:
1.Master code must be 6-8 digits,user PIN is 4-6 digits, The 1st digit of user PIN must be 1.
2.the user ID number is any number among 1-2000,Invalid 0 can be omitted; card number must be 8 or 10 digits,if the card number is
less than 8 or 10 digits, input 0 before the card number.
3.Door open time is 0-99 second,0=50mS
4.when register one card user into the device, the device will automatically generate a PIN 1234 , this PIN cant open the door door.
5.when an invalid master pin is pressed the device will go back to the standby status after 5 seconds, when a valid PIN is entered it will
go back to standby status after 30 seconds.
6.in operating the keypad, pressing # means to confirm the input digits ,In operation of a cycle adding or deleting cards, pressing #
means to end the cycle operation and back the up operation; pressing * means to exit the operation.
7. When add a series cards, this unit will make the ID number and card number initial value; after adding one user, then it will increase
the ID number and card number automatically ,Until the specified number of card is added.the card number must be consecutive card
quantity is between 1-2000.
8. Working mode and keypad transmission format have been set before shipping, customer can change according to requirement, but
when device reset to factory default, the setting is still valid.
9.when users is registered successfully, LED will turn green.
8. Administrator setting
Administrator setting on keypad
Press * Master code # factory default:999999,
8.1 Change the master code
Press 00 new code # repeat new master code#
Note: Master Code length:6~8 digits
9 User Operation
9.1 Entry by card mode,Set multi cards to open door when card quantity is 1
Read user card, lock will be unlocked
9.2 Entry by card mode,Set multi cards to open door when card quantity is 2-10
Read these cards one by one, present each card in 5 seconds, lock will be unlocked
9.3 Entry by card and PIN
Present card, then press PIN(4 to 6 digits ), #, lock will be unlocked
9.4 Entry by card or PIN mode
Present card, lock will be unlocked
Or Press PIN(4 to 6 digits ), #, lock will be unlocked
9.5 Relay mode
Relay setting -pulse mode
every time a valid card/tag read or PIN input, the relay will operate, for the pre-set relay pulse time.
Relay setting-Toggle mode
Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again
*, read user card, press old PIN, #, new PIN # new PIN #
Or *, press ID number # old PIN# new PIN # new PIN #
Notice: user who dont have user card must get ID number and origin PIN from Admin, users PIN must start with 1.
In this mode, the access control works as reader,connected with the common access controller, it has following function.
Modify master pin
Set facility code
Set the card transmission format
Set the keypad transmission format
Set optional setting
When LED level is low,indicator light(LED) will turn into green, after 30 seconds or LED level rising, LED will back to normal.
When BZ level is low,the buzzer will beep,after 30 seconds or BZ level rising, the buzzer will back to normal.
When it used as the reader, both card number and keypad transmits in Wiegang format,the output data are shown by the low level of
DO&D1 wire:
D0:low level means 0,green wire
D1:Low level means 1,white wire
Model 1: 4 Bit
The output data is provided in following format after every key is pressed:
Model 2: 8 Bit
The output data is transmitted in following format after every key is pressed:
Please note only installer data is restored, user data will not be affected
13 Packing List
Name Model/size Quantity Remarks
Keypad CC6/CC2 1
User manual CC6/CC2 1
Self tapping screws Φ4mm×27 mm 2 Used in fixing
Rubber plug Φ6mm×30 mm 2 Used in fixing
Star screw driver Φ20mm×60mm 1 Special for Keypad
two-electrode valve 1N4007 1
Warm Tips
* Please do not to repair the device privately, if have problem, please return to the supplier.
*Before installation on wall, please check carefully concealed wiring or wire tube, in case of he trouble from broken concealed
wiring etc when drilling, please use safe glasses when drilling or fixed line clip.
* if the poduct update, manual may be different,Without Prior Notice.