Online Double Conversion UPS

UPS 10 KVA -300 KVA


The Falcon 8500 has been developed by a World Class R&D team, with over three decades of power electronics
experience for the harsh power and site conditions prevalent in India and other developing countries.

ʹ˔˟˖ˢˡʫʨʣʣ˦˛˔˥˘˦˧˛˘˖˛˔˥˔˖˧˘˥˜˦˧˜˖˦ˢ˙˧˛˘ʹ˔˟˖ˢˡ˕˜˥˗˦˪˛˜˖˛˜˦˔˥˨˚˚˘˗˔ˡ˗˔ˡ˜ˡ˖˥˘˗˜˕˟˘Єˬ˜ˡ˚ˠ˔˖˛˜ˡ˘
and one of the fastest creature on the planet with the ability to move and change direction very quickly. Similarly,
the Falcon UPS is an incredible power protection system designed and manufactured in India to global IEC
standards.

Highlights of Falcon 8500 UPS at a Glance


Flexibility
• Inbuilt Isolation Transfomer
• Compatible for medical imaging equipment
requiring low mains resistance
• Compatible with all types of loads including
regener ative loads,lifts, escalators and lighting
loads
• 1+1 parallel redundant configuration with Common
battery bank
• Rectifier current limit setting for optimised
upstream infrastructure
• Parallel upto 3 units for capacity or redundancy

Reliability
• Operating temperature of 0-40oC with special
attention in component selection and design to
improve reliability
• Advanced battery management techniques to
improve battery life with three stage charging and
with auto equalizing charge at predefined intervals
• Advanced thermal protection of IGBT.

Total Cost of Ownership


ʝʺ˟ˢ˪˕˔˥˜˦˔ˣˣ˟˜˖˔˕˟˘˙ˢ˥ʩʣʠʤʥʣ˞ˉʴ
• Intelligent Eco mode operation with an efficiency of
upto 99%
• Long Life power electronics grade capacitors

Applications
• Infrastructure
• Commercial Offices & Malls
• Lifts & Escalators
• Medical Imaging Equipment
• Engineering Industry
• Process Industry

2
Reliability
The Falcon UPS family is designed for harsh conditions CANBUS Communication
seen in India, Middle East, Africa and ASEAN countries.,
Like high ambient temperatures, very high humidity, l/o
wide input voltage fluctuations, and operation on DG
MCU
Sets during powercuts which are not seen in many
parts of the world.

The Falcon UPS is designed for continuous operation With CAN


at 40ºC ambient temperature with special attention
Simplified CANBUS Communication Protocol
to details in component selection and design to
improve reliability and life under demanding
conditions. Complexity of control wiring within the UPS Special Design Heat Sink
has been simplified using CANBUS communication
protocol for higher reliability and trouble - free
operations.

Flexibility Special Heat Sinks with large surface area for


effective heat dissipation in small volume.
Falcon 8500 deploys a sophisticated control circuit
with power walk-in function to achieve progressive
rectifier start-up to avoid the impact of inrush Rectifier Delay Start
current on the upstream breakers and to avoid the Black Out
step loading on generators.
Input
Voltage t
Falcon 8500 has also been designed with Rectifier
current Limit function, taking into account the short Rectifier Delay Start Power Walk in
term momentary loads which allows the system to Input
work in parallel with the battery and to reduce the Curent

maximum demand on the mains or avoids the t


need to enhance the maximum demand
to t1 t2
sanctioned by the utility provider or generator.

Inbuilt isolator switches for input, output, Output


Voltage t
battery and maintenance bypass gives the
flexibility to connect the cables directly on the UPS
system without any external distribution panel Rectifier Current Limit
requirement.
KW

Load shared by
UPS & Battery

Load Supported
by UPS

Duration in Seconds

3
Compatibility with Loads
UPS with DBR
An advanced PWM (Pulse Width Modulation) SVM
(Space Vector Modulation) digitalcontrol technique, QS5

to modulate the inverter, provides fast transient


response with high efficiency. SVM also allows the UPS
Input
to adapt the PWM switching to different loading Output
QS1 QS4
conditions such as: partial load, full load, linear load,
QS2
non-linear load, static load, pulsating load.

Falcon 8500 comes in-built* with Special IGBT IGBT Battery


controller for adding external breaking resistors to R
Dynamic Breaking
Resistor
make the UPS compatible with regenerative loads like
Metal forming and Elevators.
User-Friendly HMI
Easy Installation
Falcon 8500 has a compact footprint and requires a
very small for installation.

The Human Machine Interface (HMI) is intuitive and


user friendly with a LCD screen and LED mimics.

Total Cost of Ownership


Falcon 8500 can be operated upto 40ºC (ambient
temperature) without precision air conditioning as
required by most UPS. This helps large saving for the
customer in CapEx and OpEx costs associated with
cooling required for the UPS. The UPS batteries must Eco mode of Operation
be kept in a separate room for safety and
temperature must be maintained below 27ºC to
maximize the life of the batteries. < 5ms
Bypass On/Off
Output Voltage

Long Life Power Electronic grade capacitors are being


Inverter Current
used in the UPS which reduces need for replacement
cost of capacitors during the life time of the UPS.
Inverter Control

Intelligent High Efficiency


Eco Mode operations which can be enabled for
energy savings (Upto 99% Efficiency). The firmware,
tested to Indian power conditions monitors the
quality of the input power, and enables the Eco Mode
operations on bypass only when input power
conditions are stable. Other wise the UPS transfers
back to double conversion mode in less than 5ms
whereby the reliability of power is ensured to the
critical load.

*inbuilt upto 20KVA (optional)

4
Series Falcon 8500
Model UPS Rating (KVA) 10KVA 20KVA 30KVA 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA

Input Rated Voltage 415 V, 3-Phase + N + PE


Parameters Rated Voltage Tolerance ±15%
Rated Frequency 50 ± 6% (60 Hz Optional)
230/240 V,
Rated Voltage 400/415 V ±10% (5-15% Selectable) 3-Phase + N + PE
Bypass Single Phase
Parameters Rated Frequency 50/60 Hz
Connection Separate From Separate From
Mains Input Common with Mains Input Mains Input
Rated Voltage 230/240 V, 400 V, 3 Phase + N + PE(380/415 V Selectable)
Output Single Phase
Parameters Rated Frequency 50 or 60 Hz ± 0.1 Hz (Configurable)
Output Power Factor 0.8 PF
Voltage Variation - Static ±1%
Load
Crest Factor 3:1
Voltage Distortion at ≤2% (Typical)
Linear Load
Voltage Distortion at
Non-Linear Load ≤5% (as per IEC62040)

Overload Capacity 110% for 60 Mins, 125% for 10 Mins, 150% for 1 Min
Load Power Factor 0.6 to Unity With In KW / KVA Rating
Up to 99% in Eco Mode and Up to 99% in Eco Mode and Up to 99% in Eco Mode and
Efficiency
Upto 90% in Online Mode Upto 92% in Online Mode Upto 93% in Online Mode
Isolation Transformer Inbuilt

Battery Nominal Battery Voltage 360Vdc 384Vdc


Parameters Compatibility Compatible with SMF, Tubular, Ni-Cd, Li-Ion Battery
Ambient Temperature 0 to 40°C (at Rated Input and Load)
for the UPS
Ingress Protection IP20 *10QUJPOBM
Range of Relative Humidity Upto 95% Max (Non - Condensing)
Environmental
Parameters Maximum Operating Altitude Up to 1000 above MSL
Storage Temperature 'SPN¡$UP¡$ 614
Acoustic Noise at 1m < 65 dBA(Ref ISO3746) < 68 dBA(Ref ISO3746)
from Panel Front
Display 128x64 LCD Graphic Display with LED Mimic
Colors RAL-7016
others
Cooling System Forced Air Cooling
Installation Free Standing with Wheels Free Standing Floor Mounting
Cable Entry Back - Bottom Entry Front - Bottom Entry
Communication
Interface (Optional) Simple Network Management Protocol (SNMP), MODBUD-RTU , Dry Contacts

Standards Safety IEC62040 - 1


Electromagnetic IEC62040 - 2
compatibility (EMC)
Performance IEC62040 - 3
Width (in mm) 500 500 500 500 500 500 500 600 600 600 600 1100 1200 1200 1200
Mechanical Depth (in mm) 700 700 800 700 700 800 800 900 900 900 900 900 1000 1000 1000
Parameters
Height (in mm) 1010 1010 1088 1010 1010 1080 1080 1400 1400 1400 1400 1750 1850 1850 1850
Weight (in Kgs) 300 300 350 300 300 300 300 550 550 550 550 1250 1400 1700 1700

Note : Specifications are subject to Change


Falcon 8500 UPS Configuration Examples

Standlone UPS Configuration Stanlone UPS with DBR

QS5 QS5

Input Input
Output QS1 QS4 Output
QS1 QS4

QS2 QS2

IGBT Battery
Battery
Dynamic Breaking
R
Resistor

1+1 Parallel UPS with Common Battery Bank Parallel UPS for Capacity or redundancy

QS5 QS5

Input Input

QS1 QS4 QS1 QS4


QS2
QS2

Battery
Output Battery

QS2 QS5
QS5

Input Input
Output
QS1 QS4 QS1 QS4

QS2

Battery

QS5

Input

QS1 QS4

QS2

Battery