GENERAL NOTES SERVICE ENTRANCE

1. ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION THE PHILIPPINE
ELECTRICAL CODE, TO THE RULES AND REGULATIONS OF LOCAL AND NATIONAL
AUTHORITIES CONCERNED AND THE REQUIREMENTS OF LOCAL UTILITY COMPANIES. FROM MAIN CIRCUIT BREAKER
400V/230V, 4-WIRE, 60HZ
USE 3#38 mm2 THHN CU, 3-150 kVA DISTRIBUTION M USE 3 SET - 3#250 mm2 THHN CU,
1#38 mm2 THHN CU(N), TRANSFORMER, OIL-IMMERSED, 1#250 mm2 THHN CU(N),
2. ALL MATERIALS TO BE USED SHALL BE APPROVED BY TYPE OF LOCATION AND PURPOSES. 1#14 mm2 THHN CU(G),
13.2kV/230V, 60HZ 1#50 mm2 THHN CU(G),
IN 35 mm Ø PVC-40 IN 103 mm Ø PVC-40
3. SERVICE ENTRY SHALL BE OF THREE PHASE 230 VOLTS.
4. THERE SHALL BE ONE DROP TO A BUILDING.
5. ALL EQUIPMENT SHALL BE ADEQUATELY AND EFFECTIVELY GROUNDED.
125AT
PB-1A 3 SET - 400AT/AF MAIN CB
A B C N

LIGHTING 1 15AT
6. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR THE PROPER IDENTIFICATION AND 15AT 2 LIGHTING
LABELING OF ALL CIRCUIT BREAKER. EACH PANEL WILL BE PROVIDED LIGHTING 3 15AT

WITH A TYPEWRITTEN CIRCUIT DIRECTORY. 15AT 4 LIGHTING


LIGHTING 5 15AT
7. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF 15AT 6 LIGHTING
A DULY LICENSED ELECTRICAL ENGINEER AND / OR MASTER ELECTRICIAN. LIGHTING 7 15AT

15AT 8 LIGHTING
LIGHTING 9 15AT

15AT 10 LIGHTING
LIGHTING 11 125AT 2 SET 300AT 125AT 150AT 30AT 150AT 30AT 100AT

VICINITY MAP
15AT
12 LIGHTING 3#38 mm2 THHN CU, 3#150 mm2 THHN CU, 3#38 mm2 THHN CU, 3#50 mm2 THHN CU, 3#3.5 mm2 THHN CU, 3#50 mm2 THHN CU, 3#3.5 mm2 THHN CU, 3#30 mm2 THHN CU,

N LIGHTING 13 15AT
15AT 1#38 mm2 THHN CU(N),
1#14 mm2 THHN CU(G),
IN 35 mm Ø PVC-40
1#150 mm2 THHN CU(G), 1#38 mm2 THHN CU(N),
1#30mm2 THHN CU(G),
IN 63 mm Ø PVC-40
1#8 mm2 THHN CU(G),
IN 35 mm Ø PVC-40
1#14 mm2 THHN CU(G),
IN 35 mm Ø PVC-40
1#2.0 mm2 THHN CU(G), 1#14 mm2 THHN CU(G),
IN 21 mm Ø PVC-40 IN 35 mm Ø PVC-40
1#2.0 mm2 THHN CU(G), 1#14 mm2 THHN CU(G),
IN 21 mm Ø PVC-40 IN 35 mm Ø PVC-40

30AT 14 CONVENIENCE OUTLET


CONVENIENCE OUTLET 15 20AT

40AT
16 CONVENIENCE OUTLET
CONVENIENCE OUTLET 17 20AT

30AT
18 CONVENIENCE OUTLET PB-1A PB-1B PB-2 MCB-3 MCB-4 MCB-5 MCB-6 MCB-7
CONVENIENCE OUTLET 19 20AT

40AT 20 CONVENIENCE OUTLET


CONVENIENCE OUTLET 21 20AT

20AT
22 ACU
ACU 23 20AT
24 SPARE
SITE SPARE 25 30AT
30AT

LOCATION 30AT
26 SPARE 100AT
3#30 mm2 THHN CU,
1#14 mm2 THHN CU(G),
100AT
3#30 mm2 THHN CU,
1#14 mm2 THHN CU(G),
100AT
3#30 mm2 THHN CU,
1#14 mm2 THHN CU(G),
100AT
3#30 mm2 THHN CU,
1#14 mm2 THHN CU(G),
100AT
3#30 mm2 THHN CU,
1#14 mm2 THHN CU(G),
40AT
3#5.5 mm2 THHN CU,
30AT
3#5.5 mm2 THHN CU,
125AT
3#30 mm2 THHN CU,
1#2.0 mm2 THHN CU(G), 1#2.0 mm2 THHN CU(G), 1#14 mm2 THHN CU(G),
IN 35 mm Ø PVC-40 IN 35 mm Ø PVC-40 IN 35 mm Ø PVC-40 IN 35 mm Ø PVC-40 IN 35 mm Ø PVC-40 IN 21 mm Ø PVC-40 IN 21 mm Ø PVC-40 IN 21 mm Ø PVC-40

NEUTRAL BAR GROUND BAR

MCB-8 MCB-9 MCB-10 MCB-11 MCB-12 MCB-13 MCB-14 MCB-15

FROM MAIN CIRCUIT BREAKER USE 3#38 mm2 THHN CU,


400V/230V, 4-WIRE, 60HZ 1#38 mm2 THHN CU(N),
1#14 mm2 THHN CU(G),
FROM MAIN CIRCUIT BREAKER IN 35 mm Ø PVC-40
USE 2 SETS - 3#150 mm2 THHN CU,
400V/230V, 4-WIRE, 60HZ
1#150 mm2 THHN CU(N),
1#30 mm2 THHN CU(G), 125AT
PB-2
IN 63 mm Ø PVC-40
A B C N

LIGHTING 1 15AT
2 SET - 300AT PB-1B 15AT 2 LIGHTING
A B C N
LIGHTING 3 15AT
ACU 1 20AT 15AT 4 LIGHTING
20AT 2 ACU LIGHTING 5 15AT
EMERGENCY LIGHTS 3 20AT 15AT 6 LIGHTING
20AT 4 EMERGENCY LIGHTS LIGHTING 7
V I C I N I T Y M A P
15AT
MESH FABRIC MOTOR 5 20AT 15AT 8 LIGHTING
SCALE NTS 20AT 6 MESH FABRIC MOTOR LIGHTING 9 15AT
PACKING MOTOR 7 20AT 15AT 10 LIGHTING
20AT 8 PACKING MOTOR LIGHTING 11 15AT
EXHAUST FAN 9 20AT 15AT 12 LIGHTING
60AT 10 DYED - IRON MOTOR CONVENIENCE OUTLET 13 20AT

LEGEND: DESCRIPTION DYED - IRON MOTOR 11 60AT 20AT 14 CONVENIENCE OUTLET


60AT 12 DYED - IRON MOTOR EMERGENCY LIGHTS 15 20AT
DYED - IRON MOTOR 13 60AT 16 EMERGENCY LIGHTS
PANEL BOARD 20AT
60AT 14 DYED - IRON MOTOR ACU 17 20AT

1 DYED - IRON MOTOR 15 60AT 18 ACU


CIRCUIT HOMERUN 20AT
PB-1
LEGEND: DESCRIPTION 60AT
16 DYED - IRON MOTOR ACU 19 20AT

30W LED PIN LIGHT DYED - IRON MOTOR 17 60AT 20AT 20 EMERGENCY LIGHTS
FACP FACP PANEL BOARD 60AT
18 DYED - IRON MOTOR EMERGENCY LIGHTS 21 20AT

50W DOUBLE LED TUBE LIGHT DYED - IRON MOTOR 19 60AT 20AT 22 SPARE
MCP MANUAL CALL POINT 40AT 20 EMERGENCY LIGHTS 23 20AT
EMERGENCY LIGHT EMERGENCY LIGHTS 21 20AT 20AT 24 SPARE
SOUNDER WITH BEAM 30AT
22 SPARE
B
50W DOUBLE LED TUBE LIGHT SPARE 23 30AT
NEUTRAL BAR
SD SMOKE DETECTOR 30AT
24 SPARE GROUND BAR

CONVENIENCE OUTLET
GROUND FAULT CIRCUIT
GFCI
INTERRUPTER OUTLET
SPECIAL PURPOSE OUTLET NEUTRAL BAR GROUND BAR

EXHAUST FAN

P - UP POP UP CONVENIENCE OUTLET

WIRING CONCEALED IN CEILING


S I N G L E L I N E D I A G R A M
SCALE NTS

JAMES F. YUTIGA PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NUMBER


ENGR. NELSON S. ANDRES, PEE Important: AL FRANCIS B. DAMASO
Ownership of Plans, Specifications, and other Contract Documents, Drawing and Specification and other IRVIN PAUL T. CRUZ
PROFESSIONAL ELECTRICAL ENGINEER contract documents duly signed, stamped or sealed as instruments of service, are the intellectual
DESIGN ENGINEER TEXTILE FACTORY AND WAREHOUSE, 3-PH, 4-WIRE, GENERAL NOTES
property and Documents of the Architect, whether the object for which they are made is executed or not.
Ms. SARAH Y. PERONA VICINITY MAP
PRC No.:

PTR No.:
VALIDITY:

DATE:
It shall be unlawful for any person to duplicate or to make copies of said documents for use in the
repetition of and for other projects or or buildings whether executed partly or in whole,
PRC No.: 51886J234

PTR No.: 6624562HH32


VALIDITY: MAY 06, 2025

DATE: DECEMBER 04, 2024


400/230V SYSTEM LEGENDS
SINGLE LINE DIAGRAM
E1
without the written consent of Architect or author of said documents.
( R.A. 9266, Sec. 33)
PLACE: TIN: PLACE: BALANGA CITY, BATAAN TIN: 188300172 LOCATION: ORION, BATAAN OWNER'S PLACE: ORION, BATAAN SCALE: 1:1 MTS DATE: 12/04/2024