Rcc-Die0009 009
Rcc-Die0009 009
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Optional accessory:
Type of Protection: flameproof enclosures "d", pressurized enclosure "p", increased safety "e", intrinsic safety "i" and type of
protection "n"
For GC8000-M400:
Type GC8000-M400C: Ex db ec ic nC pxb pyb IIB + H2 T3 Gb
Type GC8000-M400D: Ex db ec ic nC pxb pyb IIB + H2 T4 Gb
Signature:
(for printed version)
Date:
(for printed version) 2023-06-01
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended
STANDARDS :
The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards
IEC 60079-1:2014-06 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:7.0
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Edition:6.0
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
Edition:4
IEC 60079-2:2014-07 Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
Edition:6
IEC 60079-7:2017 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:5.1
This Certificate does not indicate compliance with safety and performance requirements
other than those expressly included in the Standards listed above.
Test Report:
NL/DEK/ExTR11.0096/07
EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:
Process Gas Chromatograph, Model GC8000-E is used for the analysis of flammable gases. The process gas chromatograph with a
containment system and a touch screen (touch panel) is protected by pressurized enclosure “p” with a continuous flow of the protective gas
(air). The Ex pxb safety device (protection system) is mounted in an enclosure in type of protection flameproof enclosures “d”.
The flameproof enclosure includes integral bushings (wire entries), blanking elements and adapters.
A flame proof pressure switch is mounted on the Ex p enclosure.
Process Gas Chromatograph, Model GC8000-M400 is used for the analysis of flammable gases.
The equipment has an electronic section and an isothermal oven 3. The electronic section is protected by pressurized enclosure “pyb” with
internal equipment providing EPL “Gc”. The isothermal oven 3 is protected by pressurized enclosure “pxb” with a containment system. A flame
proof pressure switch is mounted on the Ex p enclosure.
Annex:
510069900-ExTR11.0096.07-Annex 1.pdf
Annex 1 to: Report No. NL/DEK/ExTR11.0096/07
IECEx DEK 11.0083X
Description
The relation between the model designation, maximum temperature of the internal ovens/heaters, temperature
class and maximum ambient temperature is shown in the table below.
Type Designation
Model code Suffix Code
GC8000- abcde*g-h*j-****-*****-*-***/*
a = Area classification
- A:ATEX for Ex db and pxb type
- B : ATEX for Ex db, pxb and pyb type
- E:IECEx for Ex db and pxb type
- M : IECEx for Ex db, pxb and pyb type
b = Oven 11)
- 1:Large isothermal oven
- 2 : Standard isothermal oven
- 4 : Large isothermal oven for type GC8000-B400* and GC8000-M400* (Isothermal over 3)
c = Oven 21)
- 0 : None
- 1:Large isothermal oven
- 2 : Standard isothermal oven
- 3 : Programmed temperature oven
d = Oven 31)
- 0 : None
- 2 : Standard isothermal oven
e = Temperature rating
Page 1 of 3
2954:2
Annex 1 to: Report No. NL/DEK/ExTR11.0096/07
IECEx DEK 11.0083X
g = Display
- N : None
- 1 : Provided
h = Power supply
- A : 100 Vac B : 110 Vac C : 115 Vac D : 120 Vac
- E : 200 Vac F : 220 Vac G : 230 Vac H : 240 Vac
j = Wiring connection
- Q : Cable packing (3/4NPT)
- R : Cable packing (M25 X 1.5)
1) Sequential codes to be selected are 100, 110, 120, 222, 230 and 400
*: Number or letter not relevant for the explosion safety properties
Electrical data
Pressurization data
Page 2 of 3
2954:2
Annex 1 to: Report No. NL/DEK/ExTR11.0096/07
IECEx DEK 11.0083X
Process data
Page 3 of 3
2954:2