DS160HKAI VX1 Datasheet
DS160HKAI VX1 Datasheet
Key Features
• Industry Standard 3.5-inch 26.1 mm Height Form Factor
• 7200 rpm Performance, SATA 6 Gbit/s Interface
• Industry-standard 3.5-inch form-factor
• Designed for 24x7 operation
• 512 MB Cache buffer helps to smooth video recording and guard against frame drops
• 550 total TB transferred per year workload rating
Specification
Item DS160HKAI-VX1
Interface SATA
Formatted Capacity 16TB
Interface Speed [6] 6.0 Gb/s, 3.0 Gb/s, 1.5 Gb/s
Rotation Speed 7200 rpm
Buffer Size 512 MB
Performance
Maximum Data Transfer 260 MB/s
Speed
(Sustained) (Typ.)
Supply Voltage Allowable Voltage 12 V [10] ± 10 % / 5 V [10] ± 5 % [11]
Environmental Limit
Item Specification
Ambient Operating 5 °C to 55 °C (No condensation)
temperature Non-Operating [14] [15] - 40 °C to 70 °C (No condensation)
Enclosure
surface Operating 5 °C to 60 °C (No condensation) [16]
temperature
Relative Operating 5 % to 90 % R.H. (No condensation)
Humidity Non-Operating 5 % to 95 % R.H. (No condensation)
Operating - 305 m to 3048 m
Altitude
Non-Operating [14] - 305 m to 12 192 m
Operating 490 m/s2 { 50 G } ( 2 ms duration )
Shock [14]
Non-Operating 1960 m/s2 { 200 G } ( 2 ms duration )
7.35 m/s2 { 0.75 G } ( 5 to 300 Hz )
Operating [15] 2.45 m/s2 { 0.25 G } ( 300 to 500 Hz )
Vibration [14]
Non-Operating [17] 29.4 m/s2 { 3.0 G } ( 5 to 500 Hz )
Reliability
Item Specification
MTTF / AFR [4] 2 500 000 hours / 0.35%
Non-recoverable Error Rate 10 error per 1016 bits read
Load / Unload 600 000 times
Availability 24 hours/day, 7 days/week
Rated Annual Workload (Total TB
Transferred per Year,R/W) 550 TB/year
Mechanical Specification
Item DS160HKAI-VX1
Width 101.85 mm
Height (Max) 26.1 mm
Length (Max) 147.0 mm
Weight (Max) 720g
[1] Number of surveillance cameras support capability is defined by performance simulation with High Definition cameras at 4 Mb/s rate. Actual results may vary based on
various factors, including the types of cameras installed, the system’s hardware and software capabilities, and the video com pression technology used, as well as system
variables such as resolution, frames per second, and other settings.
[2] Definition of capacity: One terabyte (TB) = one trillion bytes, but storage capacity actually available may vary depending on operating environment and formatting. Available
storage capacity (including examples of various media files) will vary based on file size, formatting, settings, software and operating system and/or pre-installed software
applications, or media content. Actual formatted capacity may vary.
[3] Workload is defined as the amount of data written, read or verified by commands from host system.
[4] MTTF (Mean Time to Failure) of the HDDs during its life time is 1 000 000 hours and AFR (Annualized Failure Rate) is 0.88 %. (POH: 8760 hours per one year of 24 x 7
operational capabilities for normal surveillance usage and environments. Average HDA surface temperature:40°C or less., workloads: 180 TB/year, which is defined as the
amount of data written, read or verified by commands from host system) Continual or sustained operation at case HDA surface temperature above 40°C may degrade product
reliability
[5] "3.5-inch" means the form factor of HDDs. They do not indicate drive's physical size.
[6] Read and write speed may vary depending on the host device, read and write conditions, and file size.
[7] Input voltages are specified at the HDD connector side, during HDD ready state.
[9] Make sure the value is not less than DC -0.3 V (less than -0.6 V, 0.1 ms) when turning on or off the power.
[10] Operating watt is measured using 80% random read/write and 20 % performance idle.
[11] The measuring method is based on ISO 7779.
[12] Vibration applied to the HDD is measured at near the mounting screw hole on the frame as much as possible.
[13] At random seek write/read and default on retry setting with log sweep vibration.
[14] Operation of high surface temperature will be shortened of the drives useful life. The recommendation operating condition of surface temperature is less than 60℃.
[15] At power-off state after installation.