FS604_4 Stg
FS604_4 Stg
0 Page 1 of 2
Combined-Tens.
Pin Reversal Deg/Mag% 162/61 144/45 156/44 146/44
Throw Loading HP 93.8 86.7 80.0 80.0
BOLD = Out of Limit
Cooper Machinery Services, its owners, affiliates, authorized distributors or agents assume no liability for any consequences, damages or loss of production as a result of use or misuse of the information or calculations contained in this program.
Page 2 of 2
PowerFlow - Omissions, Exceptions and Overrides
Customer/End-user: ID#: 25006-02820-15301-08848-45704
Site Location: Case #: n/a
Version: 1.18.1.0
Date: 12/17/2024, 1:47 PM
Normal Used
Maximum Allowed Discharge Temperature: 350 degF 350
Minimum Allowed Suction Volumetric Efficiency: 15 % 15
Minimum Allowed Discharge Volumetric Efficiency: 10 % 10
Minimum Allowed Degrees of Pin Reversal: 60 deg 60
Minimum Allowed Opposite Force for Pin Reversal: 10 % 10
Throw/Cyl. Overrides: Throw #1 Throw #2 Throw #3 Throw #4 Throw #5 Throw #6 Throw #7 Throw #8
Distance Pieces: 1 1 1 1
HE Bore Diameter (in):
Added HE Clr. (%):
HE MAWP (psiG):
HE Tail Rod Diam. (in):
CE Bore Diameter (in):
Added CE Clr. (%):
CE MAWP (psiG):
Valves: HE-Suction: Review Review Review Review
Valves: HE-Discharge:
Valves: CE-Suction:
Valves: CE-Discharge: