0% found this document useful (0 votes)
198 views

Grid Complaince Study using PSCAD 2025

Uploaded by

James George
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
198 views

Grid Complaince Study using PSCAD 2025

Uploaded by

James George
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

GRID COMPLAINCE STUDY FOR RENEWABLES USING PSCAD

7.00 pm to 9.00 pm IST


Monday, Wednesday & Friday – 30 Days / 60 hours
Introduction to Grid Compliance: - 27-01-2025
- Why grid compliance study?
- Various Grid codes and standards
- Studies to be performed in EMT Simulation
- Why the grid integration study needs to be
performed in EMT apart from RMS software’s
(Electromagnetic transient (EMT) vs. RMS
simulations)
PSCAD Introduction: 29-01-2025
- Why PSCAD & When PSCAD?
- PSCAD Environment
- How to create new case/project, creating new
library & loading a existing project, saving a
project & Workspace, library
- How to access the master library, selecting an
item, adding components
- How to model a network, measure the values,
plot the graph
- How to run the simulation, changing PSCAD plot
Step, Project Settings (Duration of run, Solution
time step)
Source Modelling: 31-01-2025
- Source Modelling Thevenin voltage Sources
- AC & DC Source, Single phase & Three phase AC
Source
- Balanced Source & Unbalanced Source
- Source Impedance in pu, Actual, Short Circuit
Current Source impedance in Positive Sequence,
Negative Sequence, Zero Sequence
- Three phase voltage source model 1,2,3
Load Modelling: 03-02-2025
- Load modelling and its type (Voltage dependent
Loads)
- How to model Constant Power Loads, Constant
Impedance Loads, Constant Current Loads
[email protected]
+91 6369 577 904
GRID COMPLAINCE STUDY FOR RENEWABLES USING PSCAD
7.00 pm to 9.00 pm IST
Monday, Wednesday & Friday – 30 Days / 60 hours
- Exponential and Polynomial Loads, Frequency
Dependent Loads
Transmission Line Modelling: 05-02-2025
- Transmission line Interface
- Transmission line Modelling
(i) PI Section
(ii) Bergeron Model
(iii) Frequency Dependent Model
- Validating the transmission line modelling
General Equipment Modelling: 07-02-2025
- How to create a module
- Shunt Reactor Modelling
- Validating Shunt Reactor modelling
- Capacitor Modelling
- How to model a Single phase and three phase
breaker
- How to create a LG, LLG or 3 phase fault at bus,
line, cable
Transformer Modelling: 10-02-2025
- Transformer Modelling
(i) Three Phase two winding transformer
(ii) Three Phase three winding transformer
- Validating transformer modelling
- Transformer modelling with and without
remanent flux
Solar PV Modelling: 12-02-2025 +
- Modelling of Generic Solar Plant
- Simple Solar Farm Model
G T

Inverter Modelling: 14-02-2025


- Generic Solar Inverter model

[email protected]
+91 6369 577 904
GRID COMPLAINCE STUDY FOR RENEWABLES USING PSCAD
7.00 pm to 9.00 pm IST
Monday, Wednesday & Friday – 30 Days / 60 hours
Power Quality Study: 17-02-2025
- Introduction to Harmonic Analysis
- Modelling of Inverter Spectrum
- Detailed Modelling of Solar Plant

Power Quality Study: 19-02-2025 Harmonic


Numbers

- What are the parameters to check in harmonic


analysis Magnitudes

- how to create current spectrum & Voltage


Phase Angles
Spectrum
- Modelling Fast Fourier Transform (FFT)
component
- how to plot THD & IHD
- What are the acceptable limits according to
various country gid codes and standards?
Power Quality Study: 21-02-2025
- Why DC Current Injection study?
- Why Inverter injects DC Current into the AC
network?
- Acceptable limits as per Standards/ Country Grid
Codes
- How to perform DC Current Injection study in
PSCAD?
Power Quality Study: 24-02-2025
- Impact of grid unbalance on the DC component
value
- Impact of SCR on the DC component value
- How to limit the DC current injection?
- Power Quality Case Study 300MW solar plant
Dynamic Study: 26-02-2025
- Overview of Grid Code
- LVRT & HVRT
- Voltage response
- Frequency response
- Active power ramping test
[email protected]
+91 6369 577 904
GRID COMPLAINCE STUDY FOR RENEWABLES USING PSCAD
7.00 pm to 9.00 pm IST
Monday, Wednesday & Friday – 30 Days / 60 hours
96.0
Equipment Modelling for Dynamic study: 28-02-
s
2025 #1 #2

- Cable and line equivalent modelling


- Transformer Scaling
User defined Model (UDM) of Inverter: 03-03-
2025
- OEM Inverter Model (Vendor Model)
- Control Parameters of Inverter
- Protection Settings of Inverter
- Validating OEM Benchmark model

SVG OEM Model: 05-03-2025


- OEM SVG Model (Vendor Model)
- Control Parameters of SVG

Power Plant Controller (PPC) Modelling: 07-03-


2025
- PPC Vendor Model
- Monitoring and Controlling parameters of PPC
- Control Modes for controlling inverter and SVG
by PPC
Fault Ride through capability test: 10-03-2025
- How to create simulation Sequence for LVRT
- LVRT (Balanced and Unbalanced fault)
- Response of Inverter and PPC during FRT test
Fault Ride through capability test: 12-03-2025
- How to create simulation Sequence for HVRT
- HVRT (Balanced and Unbalanced fault)

[email protected]
+91 6369 577 904
GRID COMPLAINCE STUDY FOR RENEWABLES USING PSCAD
7.00 pm to 9.00 pm IST
Monday, Wednesday & Friday – 30 Days / 60 hours
Fault Ride through capability test: 17-03-2025
- What are the parameters to check in FRT test
(Voltage, Real power, Reactive power)
- LVRT & HVRT threshold limit
- LVRT & HVRT K factor
- Parameters tuning during FRT test

Frequency Response test: 19-03-2025


- How to create simulation Sequence for frequency
response
- Response of PPC during frequency response
- With Frequency Flag Support
- Without frequency flag support
- Frequency droop and deadband
Voltage Response test: 21-03-2025
- How to create simulation Sequence for voltage
response
- Response of Plant to change in grid voltage
- Response of PPC during voltage response
- Voltage droop and deadband
Active power ramping test: 24-03-2025
- How to create simulation Sequence for Active
power ramping test
- Rate of change of power output
- Active power ramping up and ramping down
Flicker Analysis: 26-03-2025
- What is Flicker Analysis?
- How to perform flicker analysis with support of
MATLAB
- Assessment of the short-term flicker value (Pst)
and long-term flicker value (Plt)
- Acceptable limits as per Standards/ Country Grid
Codes

[email protected]
+91 6369 577 904
GRID COMPLAINCE STUDY FOR RENEWABLES USING PSCAD
7.00 pm to 9.00 pm IST
Monday, Wednesday & Friday – 30 Days / 60 hours
Case Study: 28-03-2025 to 09-04-2025
- Power Quality Study for 300 MW Solar Plant
- Dynamic Study for 300 MW Solar Plant
- Dynamic Study for 526 MW Wind Plant

Q&A and Assignment Review:

[email protected]
+91 6369 577 904

You might also like